Home

s-via-cm14-user

image

Contents

1. 2003 2013 Onset Computer Corporation All rights reserved Onset and HOBO are registered trademarks of Onset Computer Corporation Part MAN S VIA Doc 7554 B 12 Bit 0 5 Volt Input Adapter Part S VIA CM14 The 12 Bit 0 5 Volt Input Adapter is used for measuring voltage levels and provides a trigger source voltage for powering external sensors and an open collector trigger The input adapter has a plug in modular connector that allows it to be added easily to a logger Specification 12 Bit 0 5 Volt Input Adapter Measurement Range 0 to 5 V Accuracy 0 025 V 0 5 full scale over full temperature range of 40 C to 75 C 40 F to 167 F Resolution 1 221 mV Input Impedance 1 M Maximum Input Voltage 30 V Sensor Trigger Open Collector Maximum sink current 115 mA On time 12 7 ms 3 Sensor Trigger Source Voltage 2 5 V 2 4 maximum current 1 mA On time 12 7 ms 3 Operating Temperature Range 40 to 75 C 40 to 167 F Housing Plastic case must be placed inside logger enclosure to protect from direct exposure to the weather User Connection Six position screw terminal strip 16 30AWG shielded cable recommended with outside diameter of 3 2 mm to 3 8 mm 0 125 in to 0 150 in Dimensions 4 5 x 4 8 x 1 6 cm 1 8 x 1 9 x 0 6 in Weight 25 g 0 88 oz Number of Data Channels 1 Measurement Averaging Option Yes Digital Filtering Automatic digital
2. below for timing diagrams 3 VOLTAGE INPUT Provides voltage input for sampling 4 TRIG SOURCE Trigger source Provides voltage from the logger s battery to power or trigger the external circuitry Maximum 2 5 V 1 mA See Operation below for timing diagrams 5 NC No connection 6 SHIELD Connects cable shield for noise suppression and circuit protection Typical Setup A typical voltage transducer setup is shown below with power and shield connections This configuration requires the transducer to be continuously powered Figure 2 Transducer setup Connecting the Adapters to the Logger To use the 12 Bit 0 5 Volt Input Adapter stop the logger and insert the adapter s modular jack into an available sensor connection port on the logger The logger automatically detects the new input adapter the next time you launch it Launch the logger and verify that the input adapter is functioning correctly Measurements are recorded in volts V See the logger manual for details Operation The 12 Bit 1 5 Volt Input Adapter uses digital filtering and optional measurement averaging to reduce the effect of noise and improve accuracy Distributed by MicroDAQ com Ltd www MicroDAQ com 603 746 5524 12 Bit 0 5 Volt Input Adapter Page 4 of 4 Regardless of whether measurement averaging is used or not each sample is comprised of a 10 3 ms 3 warmup period and a 2 4 ms 3 sample period During the sample period dig
3. ction against moisture but if you observe heavy condensation consider the following options Verify that the logger is installed properly and sealed according to the instructions given in the logger user manual Consider moving the logger to a location that is better protected from moisture is better ventilated or receives some sunlight to help keep the logger dry Apply WD 40 LPS 1 or 711 to the six position terminal block and the modular connectors to displace moisture and help prevent corrosion Other spray lubricants may be appropriate check product labeling to ensure that it is safe to use on plastics and electronics Verifying Accuracy You should check the accuracy of the 12 Bit 0 5 Volt Input Adapter annually Verify the accuracy of the input adapter against a known standard such as a calibrated voltage source If it is not providing accurate data it may have been damaged If you are unsure of the input adapter accuracy you can send it back to Onset for re certification Contact Onset or your place of purchase for details on sending it back Distributed by MicroDAQ com Ltd www MicroDAQ com 603 746 5524
4. filtering with 32 readings sample in 2 4 ms Bits per Sample 12 Length of Network Cable 14 cm 5 5 in Part Number S VIA CM14 The CE Marking identifies this product as complying with all relevant directives in the European Union EU A single logger can accommodate up to 15 data channels and up to 100 m 328 ft of network cable the digital communications portion of the input adapter and smart sensor cables although available space in the enclosure may limit the number of sensors you can attach Distributed by MicroDAQ com Ltd www MicroDAQ com 603 746 5524 12 Bit 0 5 Volt Input Adapter Page 2 of 4 Inside this package 12 Bit 0 5 Volt Input Adapter Hook and loop tape Three cable ties Mounting Use the self adhesive hook and loop tape included in the package to mount the input adapter inside the logger enclosure To mount more than one adapter use the back of the logger enclosure door For the HOBO Micro Station you can place the input adapter inside the logger enclosure and allow it to float freely It is not necessary to use the hook and loop tape Mounting Considerations If sensor cables are left on the ground use a conduit to protect against animals lawn mowers exposure to chemicals etc Refer to the logger manual for additional details on mounting Attaching Sensor Cables Insert the cable through the opening at the bottom of the logger enclosure as described in the logger
5. ital filtering is accomplished by taking 32 readings These readings are then averaged to produce a single measurement as shown in the following diagram Figure 3 Measurement averaging not to scale Optional measurement averaging can be selected at launch Use measurement averaging if measurements may fluctuate significantly within the logging interval Measurement averaging helps to prevent the sampling error known as aliasing To use measurement averaging set the Sampling Interval to a rate that is faster than the logging interval When measurement averaging is selected in this way the adapter takes several measurements during the logging interval and averages them to produce a single logged data point For example if the logging interval is 10 minutes and the sampling interval is 1 minute each recorded data point is the average of 10 measurements Note that fast sampling intervals less than one minute significantly reduce battery life For more information about sampling intervals refer to the logger manual Maintenance With normal usage if the adapter is installed correctly the adapter s circuitry is protected against excessive moisture and does not require any maintenance or cleaning However in an unusually wet environment excessive moisture can collect in the logger enclosure and adversely affect measurement accuracy and communications in the adapter module The circuit board is conformal coated to provide limited prote
6. manual Be sure to provide drip loops underneath the logger to prevent water from trickling up the cable and into the logger Pack the opening with duct seal For the HOBO Micro Station bring the cable through the logger s sensor port See the HOBO Micro Station User s Guide for details on removing the dome nut and stuffing gland from the sensor port Ensure that the cables to the sensor are the appropriate size for the stuffing gland 0 125 0 15 inches Be sure to provide drip loops underneath the logger to prevent water from trickling up the cable and into the logger Use the included cable tie to provide strain relief to the cable or individual wires as shown below Figure 1 Cable strain relief Distributed by MicroDAQ com Ltd www MicroDAQ com 603 746 5524 12 Bit 0 5 Volt Input Adapter Page 3 of 4 Sensor Input Connections The 12 Bit 0 5 Volt Input Adapter utilizes a 6 position screw terminal block for sensor connections with wire sizes ranging from 16 to 30AWG Pin numbers names and descriptions are as follows Pin Pin Name Description 1 GROUND Ground Used as a common connection 2 TRIG OPEN COLL Trigger open collector used to activate external sensors Provides a switched ground for external power sources connects to ground when trigger signal is true Can also be used in conjunction with external pull up resistor to trigger external circuitry Maximum 30 V 115 mA See Operation

Download Pdf Manuals

image

Related Search

s via cm14 user

Related Contents

- Journal of Universal Computer Science  Voir la documentation  Conduire de manière active  Fresh 'n Rebel ROCKBOX FOLD  Philips SRU3007 Big button Universal remote control  Philips HD2100/03 pressure cooker  防災ラジオ利用方法(PDF:107KB)  Mobile Video Studios TFT LCD Monitors Digital  取扱説明書 - SOOKI  Quantum Evo Stainless  