Home

iFuge BL08 VT - Pretech Instruments

image

Contents

1. i Fuge BLO8 VT Smart Personal Centrifuge PRODUCT USER MANUAL Contents Standard Parts Listing Introduction Intended Use Features Specifications Standard Accessories Operating Conditions and Precautions Installation Operation Care amp Maintenance Warranty Statement Product Disposal User Guide N OA Ui BR WW N B l oO Or 17 18 19 User Guide STANDARD PARTS PROTECTIVE LID ROTOR SAFETY SWITCH RELEASE BUTTON TIMER KNOB SPEED KNOB DISPLAY POWER SOCKET ON OFF SWITCH NON SLIP RUBBER BASE User Guide INTRODUCTION Congratulations You are using long lasting brushless motor personal centrifuge Thesmart microprocessor controlled variablespeed and time personal Micro Centrifuge offers versatility simplicity safety and ease of usageina single package This product comes with unique features like imbalance detection amp closed loop control Thisproducthasbeendesignedafterstudying centrifugeand its usage in innumerable scenarios of lab environment The Micro centrifuge is supplied with 2rotors roundrotorformicrotubesandstriprotorforO 2mlPCRstrip tubes The8x 2 1 5ml rotor can centrifuge up to 8 individual 2 1 5ml plastic micro tubes amp comes with reduction adaptors The strip tube rotor is designed to centrifugetwo strips of 8x0 2ml strip tubes This Micro centrifuge is specially suitablefor Microfiltration
2. Wrench To loosen Motor Shaft Insert Hexagonal Allenwrenchintothe marked hole provided ontheside of therotor The grubscrewislocatedatthebottomoftherotoronthe markedsi de To remove the rotor turn anticlockwise to loosen the screw and then gently pull upthe rotor up vertically Insert the new rotor from the top tighten screw which is located under the bottom of rotor Turn clockwise to tighten screw which is located under the bottom of rotor Please checkthe rotor is tight enough to avoid accident Note Tightening the screw will be in clockwise direction and the loosening will be counterclockwise direction 12 User Guide Time amp Speed Settings and Display time indicator display infinite time display Time control Speed control and display The unit is equipped with a 0 25 minutestimer Byoperatingthetimer knob one can set the desired time cycle The time increments decrements will be in minutes and will show on display and indicator The timer can be set from 00 to 25 minutes ifthe userneedsto operate withouttime control he can changeit tonextpositionafter25 hereitwillbe set to infinite time i The timer usedisacountdowntimerandcanbe reset or adjusted in between the runs 00 actually means stop tothe centrifuge 13 User Guide 14 speed indicator time indicator During the running of centrifuge the time and speed will be displayed alte
3. cellseparations centrifugal tube sedimentation and spin down applications Please read this manual thoroughly before operating the centrifuge INTENDED USE Centrifuge is used in various laboratories to separate particles from suspension oreven marcomoleculesfromsolutionsaccordingtotheirdensity The different biological substance that are usually separated by centrifugation are microbial cells mammalian cells organelles proteins DNA and RNA Itis majorly used in research laboratories Note This user guide is intended to assist with the operation and care of the unit only and not for its repair Thecustomershouldnotattemptto serviceor repair the unit If repairs are required please contact your supplier Foryourreference makea noteoftheserial number dateofpurchase and supplierhere Serial No Date Purchased Supplier User Guide FEATURES BLDC MOTOR FRO MAINTENANCE FREE LONG LIFE CLOSED ROTOR LEADS TO LESSER FRICTION REDUCING NOISE amp HEAT GENERATION 8 POSITION MICRO TUBE ROTOR DIGITAL DISPLAY ALTERNATES BETWEEN SPEED AND TIME HIGHLY EFFICIENT amp ACCURATE WITH 25 RPM MICROPROCESSOR BASED CLOSED LOOP SYSTEM CLOSED LOOP SYSTEM SELF ADJUSTS TO VARYING LOAD CONDITIONS TO DELIVER SET RPM SPEED amp TIME SETTING FEATURE DIGITAL TIMER PROGRAMMING FUNCTION VARIABLE SPEED SETTINGS RPM INCREMENTS AT 100 RPM ELECTRONIC SAFETY BRAKE ON LID OPENING FOR USER SAFETY IMBALANCE CUT OFF SAFETY QUICK START amp S
4. 1 5 ml 2 0 2 ml 1000 35 5 47 52 54 52 2000 142 188 208 217 208 3000 319 424 468 488 467 4000 567 753 832 868 830 4500 718 953 1053 1098 1050 5000 886 1177 1300 1356 1297 6000 1276 1695 1872 1952 1868 User Guide OPERATING To operatethis personal Micro Centrifuge below steps should be followed 1 Switch On the centrifuge from rear side so that display will show you the readings Note En Symbol indicates that Imbalance detection feature is enabled 2 Load the Rotor symmetrically to avoid accident and damage of centrifuge 3 Closethelidtostartthe centrifuge Usespeedknobtosetthespeedandthe timer knob to set the runtime 4 thecentrifugation is completed either use speed knob or use timer knob to bring the display value to zero This will gradually stop the rotor 5 If you want tostopthecentrifugequickly pushthelidrelease button and will the rotor will stop within 2seconds 6 Aftertherotorhas stopped press the release button and open lid with your thumb infront and fingers on the top simply lift the lid back onthe hinge In the following pages the routine centrifuge operation procedures are explainedinbrief User Guide Balancing the Rotor PICTURE 1 TO CENTRIFUGE 8 SAMPLES AT ATIME FILL 8 TEST TUBES EQUALLY THEN INSERT THEMINTOTHEHOLES OFTHE ROTOR AS SHOWNIN PICTURE1 PICTURE 2 TO CENTRIFUGE 4 SAMPLES AT A TIME FILLT HE 4 TEST TUBES EQUALLY THEN INSERT THEM INTO ALTERNATE HOLES OF THE ROT
5. ORAS SHOWN IN PICTURE2 PICTURE 3 CENTRIFUGE 3 SAMPLES TIME FILL THE 3 TEST TUBES EQUALLY WITH ORIGINAL SAMPLES THEN INSERT THEM IN ALTERNATE HOLES OF THE ROTOR NOW FILL A TEST TUBE WITH WATER AND INSERT INTO REMAINING ALTERNATE HOLE FOR BALANCING THE ROTOR AS SHOWN IN PICTURES User Guide Balancing the Rotor PICTURE 4 PICTURE 5 PICTURE 6 TOCENTRIFUGE2SAMPLESATATIME FILL 2 TEST TUBES EQUALLY THEN INSERT THEM INTO THE HOLES OF ROTOR IN OPPOSITE DIRECTION AS SHOWN IN PICTURE 4 POSITIONS CANBE1 5 2 6 3 7 4 8 TO CENTRIFUGE 1 SAMPLE FILLA TEST TUBE WITH SAMPLE THEN INSERT INTO ANY ONE HOLE OF THE ROTOR NOW INSERT 1 TEST TUBE FILLED WITH WATER IN OPPOSITE DIRECTION OF THE SAMPLE AS SHOWN IN THE PICTURE 5 TOCENTRIFUGE16SAMPLES FILLALL TEST TUBES WITH SAMPLE THEN INSERT INTO THE HOLES OF PCR ROTOR IN OPPOSITE DIRECTION AS SHOWNINTHEPICTURE6 PLACETHE2 PCR STRIP TUBE IN OPPOSITE DIRECTION User Guide 3 4 5 U 0 2 ML 0 4 ML 0 5 ML 1 5 ML 2 0 ML 1 5 ML 2 0 ML 6 7 8 NV 1 5 ML 2 0 ML 1 5 ML 2 0 ML PCR STRIP 8 DIFFERENT TYPES OF TEST TUBES CAN BE CENTRIFUGED BY USING TWO INTERCHANGEABLE ROTORS ROTOR 8 SLOT PCR ROTOR 8 x 0 2 0 4 0 5 1 5 2 ml 16 x 0 2 ml User Guide Changing the Rotor Sticker Mark e eee Rotor
6. TOP FOR SPIN DOWN SMOOTH AND QUIET RUNNING TINY FOOTPRINT CAN SQUEEZE EASILY ON TO A CROWDED COUNTER TOP INTERCHANGEABLE PCR ROTOR amp ADAPTOR LOW VOLTAGE INSTRUMENT WITH EXTERNAL POWER SUPPLY SPECIFICATIONS MOTOR TYPE MAXIMUM SPEED SPEED TYPE SPEED ACCURACY MAX RCF SIZE LxWxH WEIGHT ELECTRICAL POWER CONSUMPTION STANDARD ACCESSORIES 2 1 5 ml rotor PCR strip rotor Allen wrench User Guide BLDC MOTOR 6000 rpm Variable speed up to 6000 RPM 25 RPM 2000 x g 162 x 157 x 116 mm 1 1 Kg 100 240 VAC 50 60 Hz 15W Individual adaptors for 0 4 0 5 ml tubes pack of 8 Individual adapters for 0 2 ml tubes pack of 8 Power Adaptor Product user manual Warranty card amp Declaration of Conformity User Guide OPERATINGCONDITIONSANDPRECAUTIONS The personal Micro centrifuge is designed to be safe under the following conditions For indoor use only Ambient temperature of 4 C to 65 C Main supply voltage fluctuations not to exceed 10 of the nominal voltage Position at least20cmfromwalls 20cmfromceilingand 20cmbetweenother products Make sure to always install the centrifuge on stableflatsurfacesonly 8 place it near theelectrical outlet Make sure toalways load the rotor symmetrically every time Each tube should be counterbalanced by an other tube Make sure to always use only specified Micro Centrifuge tubes made from plastic and designed to withstand centrifugal forces
7. d En Sthecentrifugeisrunningwithan unbalanced rotor by not placing the weights on the rotor equally and symmetrically itmayleadtoexcessivevibrationsresultingindamagetothe centrifuge This centrifuge has an unbalance detector to protect the centrifuge its user and its surroundings against such an accidental run When such an event occurs the piezoelectric sensor build inside the centrifuge willsense the resonance created by unbalanced rotor amp willshut down the centrifuge indicating the event by flashing ub User Guide 16 Useraction Open the lid of centrifuge correct the unbalanced load by various methods described rotor loading part of the manual Then close the lid of the centrifuge resetthecentrifuge Resetting is done by switching off and again switching on the centrifuge by using the on off switch located on the rear side of the centrifuge CARE amp MAINTENANCE Your personal centrifuge and its rotor should be cleaned periodically ensure thatwhilecleaningtheunitisnotpluggedin TocleanthepersonalCentrifuge use damp cloth and a mild noncorrosive detergent ph lt 8 Do not immerse thecentrifugeinliquidorpourliquidsoverit Excessive amountsof liquid should be avoided Liquid should not come into contact with the motor After cleaning ensure all parts are dried thoroughly before attempting to operatethe unit Should aspillofinfectious materials occur withintherotororrotorchamber the unit should be dis
8. infected This should be performed by qualified personnel with proper protective equipment Do not use any cleaning or decontamination methods except those recommended by the manufacturer check with the manufacturer that the proposed method will not damage the equipment User Guide WARRANTY STATEMENT This products is warranted to be free from defects in material and workmanship for a period of one 1 year from date of purchase Your product will be duly repaired upon prompt notification in compliance with the following conditions This warranty is valid only if the product is used for its intended purpose and within the guidelines specified in this instruction manual This warranty does not cover damage caused by accident neglect misuse improper service natural forces or other causes not arising from defects in original material or workmanship This warranty does not cover any incidental or consequential damages commercial loss or any other damages from the use of this product This warranty does not cover motor brush or damage to paint or finish and defects or damages caused by physical and chemical abuse or normal wear and tear The warranty is invalidated by any non factory modification which will immediately terminate all liabilities on us for the products or damages caused by its use The buyer and its customer shall be responsible for the product or use of products as well as any supervision required for safety If requested
9. of atleast 20009 Do not use the centrifuge inanymannernotspecifiedintheseinstructions Do not operate the centrifuge without the rotor beingproperly attached to theshaft after rotor assembly re check by trying to pull out the rotor using manualforce Do not move the centrifuge while the rotor is spinning Do not fill tubes while they areintherotor liquidspillagemayharmtheunit Do not put hands in the rotor unless the rotor has completely stopped Do not centrifuge flammable explosive or corrosive materials Do not use solvents or flammables nearthisorotherelectricalequipment For safety we have provided protective earthing with power supply In case of the unit dropping from the table please check the casing for any cracks damage User Guide INSTALLATION POWER SOCKET The smart BLDC variable speedandtime Micro Centrifugeis suppliedina Box Open the Box then gently remove centrifuge from Box and connectthe power adaptor The instruction manual and the accessories should be kept withthe centrifuge Please keep all packagingin safestorageforatleast 1 year for warranty purposes Make sure to tighten it using the allen wrenchto avoid any accident Load the rotor with Micro tubes forcentrifugation Putontheswitch ontherear setthe desired speed and time and close the lid to start centrifugation For More Clarification Refer RCF Chart as below RCF CHART RPM ROUND ROTOR PCR STRIP 0 2 ml 0 5 ml
10. rnatively accompanied by time indicator and speed indicator respectively Quickspinfunction By keepingthetimerto infinity andspeedtoany suitable speed one can open and close the lid to operate the centrifuge in quick spin functionmode Speed control Speed is changed by rotating the speed control knob While adjusting the when controlling the speed the speed indicator comes on The minimum increment or decrement will to the order of 100 RPM The speed indicator reading is red with multiplication factorof 100 togettheactual rpm The rpm indicator shows the set rpm not the actual rpm dependingon the loadandtherotorusedtherpmwilldifferslightly fromthe set rpm See the calibration function to set the speed accurately Ref value Based on the speed and rotor the rcf will vary one can use table given on theinstallation page of this booklet to get the RCF of different rotors at certain given speed values Imbalance detection Activation De activiation imbalance activated display imbalance de activated display when you switch onthe centrifuge either it shows If the display shows dS it means the imbalance En or dS If the display shows En that means the detection is de activated imbalancedetection is activated User Guide User can activate and deactivate the unbalance detection in minor unbalace of the rotor by long pressing of the timer knobasshownin above picture When imbalance detectionisactivate
11. s to business sphere to which this product is assigned may no longer be disposed off in municipal or domestic waste They are marked with the following symbol to indicate this As disposal regulations within the EU may vary from country to country please contact your supplier if necessary eu Om 3 Ie of e SIA Neuation Technologies Pvt Ltd o J Plot 16 Part of gt GIDC Electronics Park SEZ 3 ze e Kolavada Road Sector 26 4 c Gandhinagar Gujarat India V Ph 2 J Fax 91 2764 248243 www neuation com A info neuation com ok d 2 2 ZN o A XY gv d SAF 3 3 2 o o A Jf e IAS SA SA PA GAN 2
12. the products must be returned to the distributor in well packed and insured manner and all shipping charges must be paid Some states do not allow limitation on the length of implied warranties or the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights This warranty is given expressly in lieu of all other warranties expressed or implied The purchaser agrees that there is no warranty of merchantability or of fitness for any intended purpose and that there are no other remedies or warranties expressed or implied which extend beyond the description on the face of the agreement This warranty is only applicable to the original purchaser 17 User Guide All items returned for service should be set postage prepaid in the original packaging or other suitable carton added to avoid damage This warranty is valid only if the warranty is registered with the supplier within 30 days from the date of purchase User PRODUCT DISPOSAL In case the product is to be disposed of the relevant legal regulations are to be observed Information on the disposal of electrical and electronic devices in the European Community The disposal of electrical devices is regulated within the European Community by national regulations based on EU Directive 2012 19 EU on waste electrical and electronic equipment WEEE According to these regulations any devices supplied after 13 06 05 in the busines