Home
        DGID Software [EN]
         Contents
1.    LED lights for a few seconds constantly  also the LED   connected to the    Relay Control Port    of EACM  green  User is identified   LED lights a few seconds constantly  red  User can not be identified    1  Insert User  Click on the button    Insert User    to create a new User   Insert new user xj    Login Mame fatlamn  First Mame lahbib  Surname Po  User Class  Normal y  Auditor Po y  Creation Date  2003 07 29  UserID   0000000293    Login Name       string used at verification time  Login Name is unique in the Host Database and has to be  entered in the maximum size of 20 characters  Note that Login Name is case sensitive  It can  be the same as the First Name of registered user    Note      Login Name field can   t be left empty  The database is checked to avoid duplicate of Login  Names      Registration Field will be filled out automatically with actual    System Date    of host and can  not be changed    User Class    Controlled  A user  who is under control of Auditor s     Auditor  A user  who controls the other user s   This user can be also a normal user   Administrator  A user  who has the right to perform tasks for user management   configuration and   maintenance of device    Normal  A user with no User Class of Admin  Controlled or Auditor    Normal  Auditor   Normal user that also has right to control Controlled users   Administrator  Auditor   Administrator  who that also has right to control Controlled users   USER ID  code generated automatically by t
2.   Verification Test    and    Identification Test              Access Control Manufacturer   entification Systems  Fabricant de Contr  le d Acc  s          The DGID and EACM Systems operate in 2 different operation modes  AS mode and FS mode   This enables you to use Embedded Biometric Systems in stand alone and network   Environments    Authentication Subsystem mode  AS mode     In this mode    Device    provides complete functionality of fingerprint biometrics  The database will be  located  activated  in device   Only an encrypted signal for successful verification   identification is  returned    Fingerprint Code Supplier  mode  FS  mode     In this mode fingerprint biometric functionality are shared between    device    and the    host     Device  captures the fingerprint and extracts the biometric data  It delivers an encrypted Fingerprint Code   FP code  to the host  The  local or remote  host manages the templates and performs the  verification   identification  The database will be located  activated  on the host     A  ADMINISTRATION    Administration    Login Name    Sumame  UserClass  Creation Date  Auditor  Enrolled Fingers  UserID  Noam 1 Administrator Nobody 6 7  Noam2 Administrator 20030716 Nobody 1 0000000088    amaud Administrator 20030716  Nobody 1 2  000000008D _  lahbib Administrator 2003 07 18  Nobody 6 ABCDEFF117    mick Administrator 20030716  Nobody  23  000000008F    olivier Administrator 2003 07 21  Nobody 2 3 ABCDEFF11E  olivier2 Administrator 2003
3.  COM Port      Identification I est       VI  NETWORK SETUP    A  SOFTWARE CONFIGURATION    The ES Manager software must be configured to start the communication between the software and the  each device     Once the software has been installed then connect the LMED RS232 to the PC   In the main menu click on Configuration        CDYI ki xX     OD CDVI Fingerprint    wt Control Manufacturer  entification Systems  Fabricant de Contr  le d    Acc  s          The configuration menu appears     Configuration       Click on the LMED icon to enter in the setup menu     4 LMED       Add  Allows you to enter the number of LMED readers on the network  The quantity can be modified  at any time     Number LMED DGID       Example  4 LMED on the network    After entering the number of LMED unit  the LMED are created automatically as follow  LMED1  corresponds to the LMED with address 1  LMED2 corresponds to LMED with address 2     4 LMED x    ad   _Bename   S  t   Delte      LMED1 p   COM1 p         Rename  Click on the Rename icon to modify the name of a device     Rename LMED    LMED1    CS Amme    Rename LMED    o K   Amter         IN         LMED x    oau    Erme  s  t   Delete at    ML  gt  om o    Select  allows to establish a communication with the LMED selected in the list        Delete  Allows to remove the LMED from the PC     Comm  Port  allows to select a comm  port     Once the LMED devices have been set in the configuration Menu  then it is possible to get in  communication 
4.  threshold is used in verification mode matching  During enrollment  a proposal for the  individual threshold is calculated  It is recommended to accept this value or you may  carefully   change it     Set template parameters for user  AERIC     Carefully click  only  on the enrolled finger     JE KE    Very Low    died EA te    Click on the button  Save Template    template and it   s set parameters will be stored in the Host  Database  After finished enrollment of a finger you will back to    Administration Window     You  can enroll other fingers for this user    Once the Template has been saved in the Host Database then it must be uploaded in the Device  Database  Select the user in the Host Database list and click on the Host User Template button   All templates from the user will be displayed  select one template and click on the icon Upload   The template is then transferred to the Devise Database        6  View Protocol    Protocol            mE    Administrator Administrator  Password Logon   Unknown 2002 04 01 21 49 58       Displays the result of identification or verification processes for all users     B  CONFIGURATION    Configuration    STRONG RECOMMENDATION   be configured ONLY    strator     Relay lime I  PR ae na A s  A ag   i       Guard  Setting up system security  software and hardware   Language  Choose another language  Currently French and English languages are supported   Device  Get device configuration     1  Security    a  Enrollment    Security Le
5.  to go back to the main menu    C  MAINTENANCE    For the Factory Use Only  A utility for update of firmware    D  TRAINING    The visual display of determined image quality and valid fingerprint area  area of fingerprint  which  is useable for the DGID reader  assists the unskilled user to learn how to capture fingerprints with  high quality     Training    Average       verage       This module is multi thread and therefore user friendly  It means user captures fingerprints again  without the need for further actions  like pressing a key or uses a mouse button    When you click on the button  Training    the LED of device      For EACM lights constantly  amber      For the DGID 3 LEDs flashes  green   One after the other showing the direction  in which the  finger have to be scanned     Note  Scan your finger as mentioned on the screen  If you can not see captured fingerprint on the  screen  then something is wrong  Perhaps the device can not communicate with host  Check the  physical connection and make sure that the DGID reader is powered     E  VERIFICATION TEST    The principle of verification is one to one    The user first types in his her  Login Name     The DGID software distinguishes between small and  capital letters  Then press on Enter or click on the button    Scan    and then scan your finger    The message  Positive verification    appears  if user is verified    The message    Verification failed    appears  if user can not be verified     Note  For a new ve
6. 0721  Nobody 1 FEDCBAATIF  olivierd Administrator 2003 07 21 Nobody 7 1234512345  raymond   Administrator 20030716 Nobody 1 2 11111111                The Administration module is used for user enrollment and management  at host and device level    Short description of some buttons     The button  Host Database       Shows the inserted user  with or without enrolled fingers into Host Database      Login Name  A unique string in Host Database      Registration Date  The date of inserting the user was to the Host Database      User  First name and Last name     User Class  See  Insert User        Enrolled Fingers  Displays which finger s  of a user is  are  already enrolled     User ID   Displays the ID which is associated to user fingers     The Button    Host User Template     Shows templates of selected user  residing on the    Host Database     You can choose one  or more   not yet implemented  template to remove it from Host Database or upload it  including related user   information  into    Device Database           The Button    Device Database       Shows the registered user templates in the device  You can delete a selected record  Template of the  enrolled finger with related user information  from database of the device  Click on the button     Delete    the selected record or to delete all records click on the button    Delete all     Click on the  button download to download the    Device database    to the    Host Database       The occupied flash memory through u
7. CDVI    Access Control Manufacturer       DGID LMED FingerPrint System     Version 3 0   for Windows  95  98  NT 4 0  2000  XP     User Manual  Sept  2003      1996 2003 CDVI   All rights reserved     TABLE OF CONTENTS    USER MANUAL    DGID FINGER PRINT IDENTIFICATION SYSTEM    E     OVERVIEW sa a da dd 3  I  INSTALLATION  HARDWARE AND SOFTWARE       essseesesessssvvvvevesssssnsnnnnessssssnnnnnnnessssnnnnnnses 4  TE   SELECT LANG UA GE 63 0 E ka Ane NE KANALEN SING 4  NN  SELECTA NTT ene  4  Ve CONTROL PAN EU aia 6      ADMINISTRA TON against 6   A TN  8  TN  9  NNN 9  NNN 9   DAE INTs ace aN EE RE EE ENA A EEA OA A iN Nel na FANS  1    e VERN 12   B  CONFIGURATION ss 13  A E E E E E A E E EE E EE E E T 13   ak  A 13   b  PECOS 10 NE EEN cate 14  NN 14   E  NNN 15   C  NNN NT ane a a a a earn eee ere ER ERE TV 15  D  TANN 16   E  VERT TVETEN 16   F  IDENTIFIGATION TEST sa 17  VE   NE E WORK SETUP sie 19  A  SOFTWARE CON EG RA TINN 19  B  SETTENE 21  C  VINGER MINNER 22    I     Overview    DGID SOFTWARE    Minimum System Requirement     Pentium CPU  166MHz   32 MB of memory   3 MB of disk space for application  5 MB of disk space during installation  A Color Graphic adapter  High Color  16 bit  at 800 x 600 Pixels    A floppy 3 5    disk drive   Windows 95  98  NT4 0  SP 6  and Windows 2000    General features     Runs under all Windows platforms  95  98  NT4 0  XP  ME and Windows 2000    Runs also on Windows driven  slow computer     486    Uses the same database structure 
8. fication Systems    Access Control Manufacturer  Fabricant de Contr  le d    Acc  s    Language     English v      Francais          English    IV  SELECT A SITE    The DGID multiple site software allows to manage and to control more than one Finger print reader  with the same software  If the site exists already choose the name in the site directory or click on the  icon    New Site    to create one  It will save the data of the new site in a separate directory        DiGital IDentification Software       Identification Systems    Access Control Manufacturer  Fabricant de Contr  le d  Acc  s       Select site    cow          If the site exists click on the drop list icon to display the site list and select in one site name     Once the site has been selected click on the    OK     button     For a new site enter the name of the site in the blank space  To save the new site press on     Enter     or  click on the     OK     button     DiGital IDentification Software    Identification Systems    Access Control Manufacturer  Fabricant de Contr  le d Acc  s    Site   New Site     NASA OK         DiGital IDentification Software          identification Systems    Access Control Manufacturer  Fabricant de Contr  le d    Acc  s       Site password   i    Ok       Enter the Password and click the OK icon  12345 Factory default Value      V  CONTROL PANEL    The DGID software consists of 6 software modules     Administration        Configuration         Maintenance        Training    
9. for databases on the device and on the host    Distinguishes between biometric and non biometric devices  connected to COM port of host     Determines automatically  which biometric device  EACM or DGID  is connected to a COM port  COMI to  COMA      DGID TECHNICAL SPECIFICATIONS    Input Voltage 12VAC DC  Current Consumption in rush 150 mA   Stores up to 1000 Fingerprints in the local database    1 Relay output N O  amp  N C contact 3A 125V and buzzer on board    3 LED   s for indication of the sweeping direction for fingerprint recognition    1 Request to Exit input   1xRS232   1xRS485    Option 26 bit wiegand Output   Tamper Switch 0 5 Amp 50 V   or   N C contact   TCP IP support on request   2 MB Flash Memory  I MB SDRAM  32 bit Hyperstone DSP RISC Processor with up to 220 MHz     High image quality and full sized fingerprint image capture based on finger sweeping with 500 dpi resolution     256 grayscales and 320 x 440 pixel   Based on the thermal electric CMOS sensor from Atmel  Finger auto detection   Self cleaning sensing area  auto cleaning    Operation temperature   30 to  70 Celsius   Naturally protected against ESD   gt  16 kV air discharge  Resistant to abrasion   gt  1 million finger sweeps   Drivers for Microsoft Windows 98 ME 2000 XP  Encrypted communication link with the PC    Support of a dynamic firmware upload respectively firmware update    II  INSTALLATION  Hardware and Software     1   Connect your device to host  on any available COM port  and ensure t
10. hat device is correctly  connected and powered on  System will automatically find out the Finger print reader is connected to  the COM port    2   Close all other Windows applications  before you start with installation of the DGID Finger print  software    Run setup located on the root of the CDROM  It is recommended to accept all default setting    At the end of Setup routine you will be asked to reboot the Installation PC   Recommended  so that all  DLLs get a chance to register themselves into system registry     3   Start the DGID software on your desktop  Automatic firmware upload and device database deletion  might appear if necessary  The    Control Panel    of the software appears  You may start    Training    to  check the availability of the    Application System        Note    The transfer of a  high resolution  fingerprint image  with a size of up to 200 Kbytes  via a slow  communication link  RS232  max  speed 10 Kbytes s  takes time  Therefore image is highly  compressed before sending it to host  Displaying of compressed image on the host is only for your  monitoring purpose  Biometrics process of image is performed in the device before compression   Device driver constantly acknowledges each received data package from the device  so that maximum  security is also obtained     III  SELECT LANGUAGE    To select a language click on the drop list and then click on the icon    Language    to confirm     DiGital IDentification Software    CDVI Fingerprint    Identi
11. he software for each user and to be used for the  UGL UGM access control systems  refer to Badge in the LOG MTSE software   The code can  be set in decimal or hexadecimal from the Configuration menu    Note  Only the user class    Normal    is supported in this version  However you can enter users  with different users class for usage in next version     2  Edit User    Change of most user information can be done here     Insert new user       Login Mame fatlamn  First Mame lahbib  Surname Po  User Class  Normal y  Auditor f y  Creation Date  2003 07 23  UserID  joooooon2g3    Note  You can not change the fields Login Name and Creation Date     3  Delete User    The user can be deleted from the Host Database  Select the user to delete and then click  on the Delete icon then a warning message is displayed to confirm the deletion  Press OK  to delete the User     The user can be deleted from the Device Database  Select the user to delete and then  click on the Delete icon then a warning message is displayed to confirm the deletion  Press  OK to delete the template of the selected User  It is also possible to delete all the templates  from the Device Database  Click on the icon    Delete All    then a warning message is  displayed to confirm the deletion of all the templates     4  Evaluation    You can also first click on the button    Evaluation    to determine  which finger of a selected user  is  are  best suitable for creation of  reference   template and then enroll the pr
12. oposed fingers by  the system     Evaluation of    HRICHARD    fingers         Click on the finger  capture fingerprint and evaluate it      The names and number s  of proposed finger s  will be displayed in status filed of  enrollment   s window  the next upcoming window  after click on    Enroll    button       You can skip the evaluation of user s fingerprints too   just click on the button    Enroll        5  Enrollment    For the enrollment of a new user one or more templates must be created for storage in the Host  Database  Each template will be created from a number of fingerprints of the same finger  That  number is adjustable  conveniently it lies in the range from 3 to 10  The default number of 5 is  recommended for most cases  After    n    accepted fingerprint images the following Window  appears   setting template parameters     Enrollment for user    HRICHARD       Average AANA AS SA Average       Finger ID  The number of enrolled finger  You have to click  carefully  on the enrolled finger   Template Quality  The template quality value is scaled within a range from 0 to 100 and has  the unit percent  100  means the highest possible quality  Template Quality is calculated  internally by the algorithm    Individual Threshold   Security Level for Verification 1  1 matching    The biometric capability varies from fingerprint to fingerprint  Hence  an individual threshold is  added to each template to reach an optimal system performance  By default  the individual 
13. opportunity to  adjust it fine  The set value of individual threshold will be stored in any template  The DGID  software sets also a default value for global threshold  which can be adjusted with care by a  skilled person    By default    Global Threshold    determines the security level in identification mode  A high set  value gives a higher security level but also the False Rejection Rate increases  FRR     Admin can change the default behavior of identification process by changing the default setting  of the above mentioned DGID software parameter    Adjustable global and individual thresholds and proper settings of related parameters enables  the    Application System    to handle fingerprints with regards to their quality     2  Password    Password administration    Identification Systems    Access Control Manufacturer  Fabricant de Contr  le d Acc  s       Password administration    OD CDVI Fingerprint    Yu Control Manufacturer    entification Systems  Fabricant de Contr  le d  Acc  s    Password administration    O C DVI Fingerprint    Yu Control Manufacturer  dentification Systems  Fabricant de Contr  le d Acc  s       To change the password click on Modify icon  Enter the new password and then enter  the password to confirm  Click on Save  To go back to the main menu click on Menu     3  Door Release Time    Relay time       To set another time click on the Relay time icon and then enter the new door release  time and click on OK to confirm  Click on the Menu icon
14. rification process  you have to enter your Login Name  press Enter or on the  Scan button and capture a fingerprint     Yerification T est       F  IDENTIFICATION  TEST    The principle of identification is one to many  The user has only to scan his  her  finger over the  FingerChip sensor    The message    Welcome User Login Name    appears  if user is identified  Otherwise appears the  message     Negative Identification        Note  For a new identification process  simply scan your finger again    Note  Identification Test and Verification Test are based on FS mode  Finger Code Supplier  used  By the DGID Embedded Biometric Device    In FS mode the biometric device  reads frames  reconstructs them to a whole image  creates  Fingerprint Code  encrypts and sends it  including a compressed image of captured fingerprint  to  the   host  The host decompresses the fingerprint image and displays it on the host screen  The host  matches  compares  the Finger Code with the template stored in the host database using    Global  Threshold     set by default 40   or individual threshold based on system settings    Note  the DGID reader distinguishes between Finger Code and template    In AS mode  Authentication Subsystems  the device performs all above mentioned functionality  including matching    In the current version of the DGID software  the device is operationally in AS mode  if it is   correctly  powered on and if the DGID software is closed  or device is disconnected form the 
15. ser information are visually displayed           The button Enrollment      First you insert a new user to the database  The new user will be inserted ONLY into the Host  Database      You select the inserted user and press on the button    Enrollment    to enroll one  or more  finger  of the selected user    You can also first click on the button    Evaluation    to determine  which finger of a user is  are   best suitable for creation of  reference   template and then immediately enroll the  by system   proposed fingers     Biometric Device operating in AS mode   host independent      To let device operates in the AS mode  it is needed that at least one user with at least one   enrolled finger is stored in the    Device Database     Otherwise the LED will remain off  when you  exit   the DGID software or disconnect the device from the host      You exit the software or disconnect the biometric device from host  but power is needed   to  identify  1 n matching  registered user fully host independent     LED functionally of device operating in AS mode    a  DGID Finger Print reader    3 LED flashes  green  one after the other Standby mode  Waiting for Scanning finger   LED flashes  green  slowly  first LED from the bottom  User can not be identified  LED flashes fast for a few seconds  green  Quality of finger is too low   LED lights for a few seconds  green  and a beep is emitted User is identified   b  EACM    LED lights constantly Standby mode  Waiting for Scanning finger 
16. vel          A O    Ver Low            Finger image to scan    The quantity of accepted fingerprint images  of the same finger  for creating a template   Minimum Image Quality    Minimum Image Quality of captured fingerprints during enrollment  Fingerprints with quality  less than this value will be rejected    Minimum valid area     Minimum useable area of captured fingerprints during enrollment  Fingerprints with quality less  than this value will be rejected       Show light fingerprint image       Show dark fingerprint image       How to display the captured fingerprints on the host screen   User ID format   allows to create User ID in Hexadecimal or in decimal     b  Recognition    Times to try   Not supported in this version     0 means no limitation    It determines how often a user can try to be identified or verified   Default setting   3    Timeout Period   Not supported in this version     0 means no limitation    Use verification method  1 1  Use identification method  1 n    Not supported in this  version    These parameter are used for identification or verification of user  who are allowed as  administrator to manage and configure the system       Always use the individual threshold    and    System global threshed      The DGID software distinguishes between individual and global thresholds    The value of individual threshold depends on template quality  The DGID software determines  and proposes this value during enrollment of finger  The Admin has also the 
17. with the LMED DGID which are networked     After entering the site password select the LMED device to which you wish to connect     B  SELECT LMED    It is possible to select another LMED device while in connection with another device  Click on  Administration icon then click on    Host User Template        Administration      IO        JO    a       Click on the icon Select LMED  then choose the LMED device     231    C  WIRING DIAGRAM    00000 D498 ou D691 Reader Controller eee    RS232       O E  0 Or PCB module  E    Recommended cable for the RS 485 1 twisted pair  shielded SYT1 9 10MM or AWG20          GND Distance between the DGID and the reader    R controller 1 km  1 5 mile  maximum           Request to    oe    Exit Input    Switch    A B  Connect to  UGM UGL   amp  UGP 40        Note   Put 120Q resistor on the  last reader controller of the  RS485 bus between A and B        O    COM     P _              o     O            N O       N C  Door  contact  innut    Input voltage    12VAC or DC       V   Varistor    99    
    
Download Pdf Manuals
 
 
    