        IDM/FIRSTVUE Interface - Welcome to Emerson Process
         Contents
1.   you can simply enter the file name  otherwise you must enter the  complete Path of the file     Next  at the ENTER DESTINATION FILE prompt  enter the name of the file you wish to ci  Follow the directions on the screen for file specification options     After you have specified a destination file  the translation process will continue  Several mess  will flash across the screen as it runs  If the translation finishes without any errors  you will se  message    TRANSLATION SUCCESSFUL    along with the file name that the process create  the translator encounters errors  an error message will be displayed at the end of the process     Notes   The translation process executes the St  Paul Software SpediTran edi translator  It uses the  specific FV to IDM translation map developed by Fisher Controls  This map links FIRST  fields to their corresponding IDM field  It does special translations for fields that are    Coc  Listed    in IDM and fields that do not have a 1 to 1 match between the two systems     IDM    Code Listed    fields are fields whose values must exist on a predefined list  Think o  them as drop downs that will only let you select a value from the drop down list  This is o  the biggest hurdles to getting data back into IDM  For this project  we have worked closel  with Intergraph to add FIRSTVUE   s attribute values  for example our materials  and drop  down lists to the IDM code lists     We recommend developing naming standards that will help both IDM and FIRSTV
2.  1998  release or newer   While most of the associated documentation refers to  FIRSTVUE  please remember that the interface is identical in FIRST     SpediTran edi translator made by St  Paul Software  To obtain SpediTran  see the  Contacts section of this document  Be sure to inquire about special pricing for Fisher  Controls and also ask about Single vs  Multi user licenses     Tranlation maps  cross reference files  and other files required for the interface  These  files will be delivered on the June 1998 CD  Again  Beta versions of these files will  be made available to Representatives needing them sooner     Software Installation    See the IDM FIRSTVUE Interface   Installation Guide  Firstvue  DMData install doc on  the CD  for instructions on installing the software required by the FIRSTVUE user     File Comparison Utility  Optional     One of the biggest issues concering electronic exchange of specification data is revision  control  To address this issue  Fisher Controls has developed a File Comparison Utility   This utility compares a file to be imported with a file that was exported and identifies data  that has changed  The utility can be used BEFORE importing data back into IDM or  FIRSTVUE  Contact Fisher Controls to obtain this free utility     IDM FIRSTVUE Interface 6 21 96    User   s Manual   Default Directories    The following diagram shows the default directories used to store files during the interface  process  Itis provided here for reference  These 
3.  The translation process will start by prompting for the file to translate  At the ENTER SOUR  FILE prompt  enter the file you wish to translate  If you placed the file in the  C  Idm_isa Incoming directory  you can simply enter the file name  otherwise you must ente1  complete Path of the file     Once you have entered a valid file name  the translation process will continue  Several messa   will flash across the screen as it runs  If the translation finishes without any errors  you will se  message TRANSLATION SUCCESSFUL    along with the file name that the process create  the translator encounters errors  an error message will be displayed at the end of the process     When the translator completes successfully  it places the resulting data file in the C  Ff_isa In  directory  It will have the same name as the source file that you entered except that its extensi  will be     BSV     BSV stands for Bar Separated Values   This is the file you will import into  FIRSTVUE in the next step     Notes   The translation process executes the St  Paul Software SpediTran edi translator  It uses the  specific IDM to FV translation map developed by Fisher Controls  This map links IDM fi  to their corresponding FIRSTVUE field  It does special translations for Unit of Measure f  and fields that do not have a 1 to 1 match between the two systems     Step 6   Import file into FIRSTVUE   FV user  This step imports the     BSV    file created in Step 5 into FIRSTVUE     1  Select Import ISA F
4.  Units  For the  interface  Thickness Units will drive what is populated in FIRSTVUE  If Thickness Units  are blank  Nominal Diameter will be mapped to Size  and Schedule Thickness will be  mapped to Schedule   it is HIGHLY recommended that Pipeline Dimensions be specified    IDM FIRSTVUE Interface  User   s Manual   Rules for IDM User  this way  be sure that the IDM default for Thickness Units is blank   If Thickness  Units are present  Nominal Diameter will be mapped to Outside Diameter  and  Schedule Thickness will be mapped to Wall Thickness   again this is NOT the preferred  method  If Thickness Units are present  they must be the same as the Diameter Units     H  The UOM   s for Inlet and Outlet Pipeline Dimensions must be the same   I  If both Body and Bonnet Material are specified  they must be the same   J  Do not enter a Vertical Bar  I  in any data     K  ISA Header and Revision data will NOT be imported back from FIRSTVUE     IDM FIRSTVUE Interface  User   s Manual   Rules for FIRSTVUE User    Rules for FIRSTVUE User    A     B     Save all import error messages to a log file  Immediately investigate log using an editor  such as Notepad     The following Sizing Conditions MUST be used     Condition I Minimum   Condition 2 Normal   Condition 3 Maximum   Condition 4 Other   Shut Off  if Other is used it will be interpreted as Shut   Off     If you copy an imported tag  you MUST update the IDM child tags at the bottom of the  Spec Sheet screen       The following FIR
5.  completed the sizing and selection process  and has reviewed  the FIRSTVUE ISA Spec Sheet for each item  it is time to export the data     1  Select Export ISA File from the FIRSTVUE file menu    Click the Browse Map button   Select the  idm csm    file    Verify that the File Delimiter is set to    I       Verify that Only Fields in Map is selected    Verify that Custom Names is selected    Select the items you wish to export  You can highlight just certain items  or select all   items by checking the Select All Items box    Click the Export button at the bottom of the window to start the export process    9  Enter the name of the export file you wish to create  We recommend that you use the  default directory  C  ff_isa export  and you use the     BSV    extension    10  As each item is exported  a message will pop up  When the process has finished   click the OK button to acknowledge the last message and then click the Close button  to close the window     rece Pao O    oe    Step 9   Run the FV to IDM translation process   FV user    IDM FIRSTVUE Interface 6 21 96    User   s Manual   Processing Steps    The FIRSTVUE user will start the translation process by executing C  Spedi fftoidm bat   The easiest way to do this is to double click the FV to IDM desktop Icon     The translation process will start by prompting for the file to translate  At the ENTER SOUR  FILE prompt  enter the file you just created in Step 8  If you placed the file in the  C  Ff_isa Export directory
6.  failed     Like the  message suggests  this item will NOT be imported     Step 7   Size and select the valves and any accessories   FV user    IDM FIRSTVUE Interface 6 21 96    User   s Manual   Processing Steps    Before starting the sizing and selection process  we recommend printing a copy of the ISA  Spec Sheet for all the imported items  Refering to this Spec Sheet will aid in the sizing and  selection process by showing any customer preferences specified on the Spec Sheet     As you select components  Spec Sheet Data will be populated  Use the User Overrides  column on the ISA Spec Sheet entry screen to complete the Spec Sheet  The User Overrides  column will be highlighted in BLUE where both a Data and a Override value have been  specified  but do not match     When filling out the Spec Sheet  the FIRSTVUE user must follow some basic Rules so that  the data will flow seamlessly back into IDM  These Rules are documented in the Rules for  FIRSTVUE User section of this manual     Notes   Non sizing fields are imported into Spec Sheet User Overrides  On export  User  Overrides always take precedence over Data that is populated during selection  Be sure to  review the Spec Sheet Entry screen for all items before going to the next step     The IDM FIRSTVUE interface is based on the ISA  20 50 Spec Sheet  So if something  does not appear on the Spec Sheet  it will probably not be sent back to IDM     Step 8   Export data to a text file   FV user    When the FIRSTVUE user has
7.  printing documents  i e  Spec Sheets  with  revision tracking  Your IDM user will know of other methods to help track revisions     To further help manage revisions  Fisher Controls has developed a File Comparison Utility to  compare export files with import files BEFORE data is re imported into IDM or FIRSTVUE   This utility is very valuable in identifying changes  To get a copy of the utility  contact  Fisher Controls     Archiving  When you run the IDM to FV translation process  one of the things it does is copy the file    you are translating  i e  the file you received from IDM  to an Archive directory  This is so  you will always have a copy of the file as it was received from IDM     Similarly when you run the FV to IDM translation process  one of the things it does is copy  the file you are sending back to IDM to an Archive directory  This is so you will always have  a copy of the file you sent back to IDM     The way these files are archived is that they are copied to a directory named Archive  The  Archive directory is added under the file   s current directory if it does not exist already  The  file is copied to a     001    extension  If a  001 version of the file already exists  it is copied to  the first available numeric extension  i e   002   003  etc   Example  You receive  PROJ1 EXP from IDM and place it in the C  ldm_isa Incoming directory  When you start  the IDM to FV translation  the file is copied to C  Idm_isa Incoming Archive PROJ1 001  If  you ever 
8.  user   Import file into FIRSTVUE   FV user   Size and Select the valves and any accessories   FV user   Export data to a text file   FV user   Run the FV to IDM translation process   FV user   Send file to the IDM user   FV user   Import file into IDM to update tags with FIRSTVUE data   IDM user    00000000000    D  lworking kevin meyer june2 lidm idm_um doc 7    IDM FIRSTVUE Interface 6 21 96    User   s Manual   Processing Steps    Overview    This section gives detail on each of the steps in the IDM FIRSTVUE interface process     Step 1   Create Tags and enter pertinent data in IDM   IDM user    The process must ALWAYS start in IDM  The IDM user will create the Tags for the control  valves he needs  He will then enter data on the requirements of the valve  Some of the data  likely to be entered are Service Conditions and Pipeline Size  When entering data  the IDM  user must follow some basic Rules so that the data will flow seamlessly into FIRSTVUE   These Rules are documented in the Rules for IDM User section of this manual and should be  given to your IDM users     Step 2   Export data to a text file   IDM user    When the IDM user has finished entering data for all the control valves he needs  he will  export the data to a text file  When exporting the data  he needs to select the  FIRSTVUE exp import description file  When naming the file he should use the standard  8 3 naming convention     Notes   We recommend developing naming standards that will help both IDM and 
9. DM and FIRSTVUE revolves around the  ISA S20 50 Control Valve Spec Sheet  All devices and fields on the Spec Sheet will be sent  from IDM to FIRSTVUE  All Spec Sheet devices and fields will be sent back to IDM except  for Header and Revision fields     The Benefits    The electronic exchange of data between IDM and FIRSTVUE will save time for users of  both systems by eliminating the re keying of data  It will also reduce data entry errors for  both users     IDM FIRSTVUE Interface 6 21 99 3 07 PM  User   s Manual   Data Flow    FIRSTVUE     IDM  AND ST  PAUL SOFTWARE       FIRSTVUE        St Paul Translator       Intergraph    Export            Text File  PDS    Dev Complete    IDM Valve  Sizing      Version  6 3 1   Selection        CUSTOMER   FISHER REPRESENTATIVE    Overview    IDM FIRSTVUE Interface 6 21 96    User   s Manual   Software Requirements    This section lists the Software required to execute the IDM FIRSTVUE Interface     Software Required  IDM User    A     Intergraph IDM version 6 3 1 or newer  This version is scheduled for release in June  1998  Beta versions may be available before then  When installing the 6 3 1 version   the user needs to select the option to install Fisher Controls reference data     FIRSTVUE User    A     Fisher FIRSTVUE version 1 0L or newer  This version will be released on the June  1998 CD  Beta versions will be made available to Representatives who need it  sooner  The IDM interface also works equally well with Fisher FIRST  June
10. FIRSTVUE  users identify a file  For example  the 8 position file name may be related to the Project  Name or Number  and the 3 position file extension may always be     exp        For this export file  and all the import export files referred to in this document  the first  record contains the field names  The remainder of the file consists of one record per  valve Tag  Fields are separated  delimited  by the Vertical Bar     1      All files are simply  text files     Step 3   Send file to the FIRSTVUE user   IDM user    If the FIRSTVUE user is a Fisher Representative  we envision that the file created in Step 2  will be sent to him as an attachment to an e mail  For special cases where the IDM user and  the FIRSTVUE user are at the same location  the file may be placed on a common network or  handed off via floppy disk     Step 4   Copy file to the incoming translation directory   FV user    When the FIRSTVUE user receives the file from IDM  he should place it in a directory on his  system or network  The delivered default directory that the translator will look for a file is  C  Idm_isa Incoming  so we recommended putting it there    IDM FIRSTVUE Interface 6 21 96    User   s Manual   Processing Steps    Step 5   Run the IDM to FV translation process   FV user    Once the file has been placed in a directory  the FIRSTVUE user will start the translation  process by executing C  Spedi idmtoff bat  The easiest way to do this is to double click the  IDM to FV desktop Icon    
11. IDM FIRSTVUE Interface    User   s Manual   Table of Contents    Topic  Overview of Project  Data Flow  Software Requirements    The Import Export Process  Default Directories  Process Overview  Processing Steps    Rules  Rules for IDM User  Rules for FIRSTVUE User    Miscellaneous Topics  Revision Tracking  Archiving    Contacts    Page  2  3  4    N    11  12    14    15    6 21 96    IDM FIRSTVUE Interface 6 21 96    User   s Manual   Overview of Project    The Project    Fisher Controls and Intergraph have worked together to develop an electronic interface  between Intergraph   s Instrument Data Manager  IDM  software and Fisher   s FIRSTVUE and  FIRST valve sizing software     The Process    The process will always start in IDM  The IDM user will enter Service Conditions and other  pertinent data  He will then export the data to a file and send it to the FIRSTVUE user   usually as an attachment to an e mail      The FIRSTVUE user will first run the file through an edi translator  St  Paul Software    s  SpediTran software  in order to translate it into a format that FIRSTVUE can use  He will  then import the file into FIRSTVUE  size and select the valve and any accessories  and export  the data to a file  Finally  the FIRSTVUE user will run the file back through the edi translator  and send it back to the IDM user  again via e mail      The IDM user will import the file back into IDM to complete the process     The Scope    The scope of the data to be exchanged between I
12. STVUE Spec Sheet Override fields are Code Listed in IDM  meaning    that IDM will only except certain values     e all fields that have a drop down list that contains the value  SEE NOTES      e all Unit of Measure fields e Line 43   Group and Div  For these fields  you must choose a value from the FV drop down list or type in a value  that you KNOW exists on the IDM code list for a particular field  If the FV drop down list  contains    SEE NOTES     you can always select    SEE NOTES    and enter the value in a spec  sheet note line     The following spec sheet override fields require a special entry format     ISA Line   Field Entry Format Example Valid  UOM s  13 In Pipeline Size  amp  Schedule Size UOM  Schedule 4 in  80 in  mm  14 Out Pipeline Size  amp  Schedule Size UOM  Schedule 2 5 in  STD in  mm  17 Valve Body Size Size UOM 8 in in  mm  33 Trim Size Size UOM 11 2in in  mm  33 Rated Travel Travel UOM 53 8 in in  mm  62 Bench Range Min Max UOM 1 5 16 5 psig psig  bar  67 Input Signal Min Max UOM 4 20 mA de psig  bar  mA  de  V de    Accessory Note Lines 45 48 are for Solenoid Valve data  Each of these lines requires  special care when entering in order to get the data imported back into IDM     Line   Label Entry Rules  45 Tag  This line contains the Solenoid Valve Tag followed by the Solenoid Valve Reset  Type     Do NOT edit the Tag Number  If there is no Tag Number  do NOT enter ANY  Solenoid data    The IDM user will normally specify the Reset Type only if he req
13. UE use  identify a file  For example  the 8 position file name may be related to the Project Name o    99    Number  and the 3 position file extension may always be     imp        Step 10   Send file to the IDM user   FV user  If the FIRSTVUE user is a Fisher Representative  we envision that the file created in Step 9  will be sent back to the IDM user as an attachment to an e mail  For special cases where the  FIRSTVUE user and the IDM user are at the same location  the file may be placed on a  common network or handed off via floppy disk     Step 11   Import file into IDM   IDM user    IDM FIRSTVUE Interface 6 21 96    User   s Manual   Processing Steps    When importing the file sent to him in Step 10  the IDM user needs to select the  FIRSTVUE imp import description file  The IDM user can refer to IDM documentation for  resolving import errors     Notes   The IDM import process is    update only     This means that all valve and accessory tags  must already exist in IDM for data to be imported  This is opposite of the FV    add only     import     IDM FIRSTVUE Interface  User   s Manual   Rules for IDM User       Rules for IDM User   A  Do not remove or modify entries in the standard IDM code lists    B  The delivered Create Script for the Control Valve will automatically generate an Actuator   Positioner  Enclosure  and Airset  If you want FIRSTVUE to be able to return a Solenoid   Switch  or Air Failure Valve  you will need to specifically create these devices  Should  
14. directories will be discussed in more detail  in following sections of this manual     IDM FIRSTVUE Interface 6 21 96    User   s Manual   Default Directories       ET Hard Drive  Usually C         Incoming          Outgoing             Files received from IDM    Files to be sent back to IDM    Files that have been translated and  ready to be imported into FIRSTVUI    Files exported from FIRSTVUE    Log files from FIRSTVUE import ex     The  csm files that tell FIRSTVUE tt  to export  Browse Map Button     IDM FIRSTVUE Interface 6 21 99 3 10 PM    User   s Manual   Process Overview  Copy file to Gu       Create Tags   2  Aj i ecf i  Enter Data Text Gaam  isa Ca idm_isa  IDM to FV caff isa  Export  gt  File incoming incoming      import                                                                       filenametxt   filename bsv    e mail        IDM User   IDM 6 3 1 FV User   e mail FV User   Translator     PO  C  idm_isa  FV to IDM Caff isa    Size and  outgoing                  e export  Export  Select    filename txt filename bsv    e mail    fo en mm S  gt   Carre DES    IDM User   IDM 6 3 1 FV User   Translator FV User   FIRSTVUE    Processing Steps  9  O     Create Tags and enter pertinent data into IDM   IDM user                                                                         Export data to a text file   IDM user   Send file to the FIRSTVUE user   IDM user   Copy file to the incoming translation directory   FV user   Run the IDM to FV translation process   FV
15. ed to Project as Item 001    will appear for each item  that is imported  If you encounter import errors  save the Import Log as directed in Step 7   above   Using a text editor  i e  Notepad   open the saved log file to investigate further   the default directory for saving the logs is C  Ff_isa Imp_log   It will be up to the  FIRSTVUE user to investigate and resolve all import errors  Some possible fixes include  carefully editing the import file or having the IDM user fix the problem and re send the  data  There are 3 kinds error messages that you may encounter     A  Fluid State Error   The only valid ISA Fluid States are Liquid  Gas  and Vapor  If  the import encounters something else  you will see the message    Error in Tag     FluidState has invalid value of    imported value     Defaulting to LIQUID for  this item     As the message suggests  the item will be imported  but its Fluid State  will be changed to    LIQUID        B  Sizing Field Out of Range   If the import encounters a sizing variable that is out of  range  you will see the message    Error in Tag    VariableName has an invalid  field value of    imported value     Value Not Set     This item will be imported  but  the value for the variable that is out of range will be blank     C  Invalid Sizing Unit of Measure  UOM    If the import encounters a sizing UOM  that it does not recognize  you will see the message    Tag    VariableName has  an invalid unit value of    imported value     Import of this Line
16. ile from the FIRSTVUE file menu    Select the file created in Step 5    Click the Browse Map button   Select the  idm csm    file    Verify that the File Delimiter is set to    I       Click the Import button at the bottom of the window to start the import process     s the import process runs  messages will appear in the Import Log  If any error  messages appear  click the Save Log button when the import process is finished   Enter the name of a file to save the log to    8  Click the Close button to close the window     Prev n    IDM FIRSTVUE Interface 6 21 96    User   s Manual   Processing Steps    Notes   FIRSTVUE imports items into the project you have open  If you get the error    Warning   No Active Document    it means that you don   t have a project open  Open a project and  try again     The FIRSTVUE import process is    add only     This means you cannot update existing  items via the import  Imported items are added to the end of the open project  For  example  if you are working in a project that already has 3 items  the first item you import  will be set to item 4  We recommend importing into a new project so that the first item  you import will be item 1     Data is imported into two places  Sizing fields are imported into sizing  Non sizing  fields are imported as ISA Spec Sheet User Overrides  Some fields are imported into  both places     Import messages will appear in the Import Log as the import process runs  A message  such as    Tag   of Import File add
17. receive and translate PROJ1 EXP again  it will be copied to   C Udm isalUncominglArchivelPROJ 1 002  and so on     You may want to come up with your own file naming and archiving methods  You may also  want to coordinate them with your IDM user     IDM FIRSTVUE Interface 6 21 96    User   s Manual   Miscellaneous Topics    IDM FIRSTVUE Interface 6 21 96    User   s Manual   Contacts    Overview    This section list individuals to contact if you have questions or need support regarding the  IDM FIRSTVUE Interface     Ordering St  Paul Software    Carleton Perry   St  Paul Software   St  Paul  Minnesota  USA   651 603 4416   cperry Q stpaulsoftware com  Note  Be sure to inquire about special pricing for Fisher Controls and also ask about Single  vs  Multi user licenses  Also  be sure to order Release 2 4b     Ordering or Installing FIRST and FIRSTVUE    Bob Maile  Fisher Controls  Marshalltown  Iowa  USA  515 754 3009  Note  Please contact Kevin Meyer before ordering any Beta software    Sales and Marketing Support    Kevin Meyer   Fisher Controls  Marshalltown  Iowa  USA  515 754 3933    Technical Support    Tim Wignall   Fisher Controls  Marshalltown  Iowa  USA  515 754 3962    
18. tered  Do not enter data  between the two tildes  as any data between the tildes is not sent back to IDM  You may  enter data before the Ist tilde and or after the 2nd tilde     Do NOT enter data for the Switch  Lines 74 78  unless the Switch Tag Number appears on  Note Line 78       Do not enter a Vertical Bar  I  or a Double Quote       in any data     After sizing and selecting in FIRSTVUE  wipeout any undesired spec sheet overrides for  each item before exporting  On export  spec sheet overrides take precedence over any valu  populated by attributes or sizing       When creating an export file  FIRSTVUE will default the Valve Manufacturer to    FISHER    if itis blank     IDM FIRSTVUE Interface 6 21 96    User   s Manual   Miscellaneous Topics    Overview    This section discusses several miscellaneous topics     Revision Tracking    Tracking revisions and data changes will be important to the successful implementation of  this interface  Good communication between the IDM user and the FIRSTVUE user will be  essential  While IDM ISA Revision fields are passed from IDM to FIRSTVUE for  informational purposes  they are not passed back into IDM  This is so the IDM user can  remain in control of his own revisions  We recommend that the IDM user always takes a  Revision just before he exports data  and right after he re imports data  This will aid in  determining what was changed by FIRSTVUE  IDM already has several useful tools for  helping tracking Revisions  One of these is
19. uires a Manual  Reset     IDM FIRSTVUE Interface  User   s Manual   Rules for FIRSTVUE User    In the rare case when you need to change the Reset Type  the valid values are      Man Reset         Man Reset NVR     and    Man Reset FH     These must be entered EXACTLY  as shown here     46 Mfg Mod  Enter the Manufacturer and the Model separated by a    7      If you enter a Model but no Manufacturer  you must precede the Model with a            47 Type Matl  Select a Body Type Body Material combination from the drop down list     48 Rating C  V  F  Enter the Current Rating and Units after the  C      Valid Units are  A  mA  Enter the Voltage Rating and Units after the  V      Valid Units are  V  mV  Enter the Frequency and Units after the    F      Valid Units are  Hz  Do NOT remove the  C         V      and    F     labels     G  Do not enter data in the Actuator On Off field  ISA Line 56   as it is not part of the  interface  Instead select a drop down choice from the Modulating field     H  If Air Fail Valve  Line 65  contains the value    NO     do NOT enter any data on this line   Otherwise  you can enter anything you wish     IDM FIRSTVUE Interface  User   s Manual   Rules for FIRSTVUE User    Rules for FIRSTVUE User  continued     I    The Positioner Note Line  ISA Line 73  and the Switch Note Line  ISA Line 78  will  contain the associated IDM Tag Number  The Tag Number will be surrounded by Tilde   s      to separate it from any note text that the IDM user may have en
20. you alter your Create Script  you will need to communicate this with the FIRSTVUE user    C  Fluid State must be Liquid  Gas  or Vapor  On import into FIRSTVUE  if something other  than Liquid  Gas  or Vapor is encountered it will be changed as follows    Fluid State from IDM Imported into FV as   Dense Phase Liquid  Slurry Liquid  Steam Vapor  Super Critical Vapor  all others Liquid   D  The Units of Measure  UOM   s  entered in IDM must be valid in FIRSTVUE  The valid  UOM   s   as they exist on IDM   s standard code lists   are    FLOW PRESSURE TEMPERATURE LENGTH VISCOSITY  Ib h psia degF in cP  kg h psig degC IN cSt  scfh bar  a  K    SSU  MMscfd bar  g  degR mm mPa s  scfm kPa  a    Nm3 h kPa  g    scfd kg cm2  a  DENSITY AREA  gpm US  kg cm   g  1b ft 3 in 2  l mkg cm2a kg m 3 mm 2   m3 h kg cm2g cm 2  barrel d in  we g   E  Specific Heats Ratio  ISA Line 7  should be entered in IDM as    K     On import  FV will  automatically convert to ISA   s    F k     by dividing by 1 4  On export  FV will  automatically convert back to    k    by multiplying by 1 4    F  Travel Units  ISA Line 10  are not included in the interface  For Sliding Stem  Travel  Units are assumed to be   Open  For Rotary  Travel Units are assumed to be Deg Open    G  For both Inlet and Outlet Pipeline Dimensions  FIRSTVUE requires either Size  amp     Schedule or Outside Diameter  amp  Wall Thickness  IDM   s corresponding fields are  Nominal Diameter  Diameter Units  Schedule Thickness  and Thickness
    