1. 130 A bP TE 11 g A d d XN 80 JI L E Ws Page 3 of 10 High Resolution Digital Crane Scale 6 Display amp Keys Scale Keys Name Function x lt D Short pressing Cancel amp return to On Off weighing mode Long pressing Power on Power off Short pressing Tare in out Increase digit Long pressing Zero Move digit Remote Keys Name Function Same as long pressing Same as short pressing x lt 10 E Hold Lock unlock Confirm amp next Auc Accumulate weight Decrease flashing digit Delete last weight Clear all weight Left scroll flashing digit View Input cancel decimal point Unit Switch rd N Long press to power off Return to weighing mode 2nd 2nd function eO 40 4 10 High Resolution Digital Crane Scale Indicators LED Note G shown when weight is stable 5 shown when weight is at zero I shown when scale is tared H shown when scale is locked L 1 shown when unit is Ib H shown when unit is kg L shown when unit is User Unit Message
2. to enter User Setup menu GEL up shows Auto Off Timing Press O to enter Auto Off Timing 9 7 shows Press or press or to change timing value Auto Off Timing can be set to disabled 5 5min 10min 0 15min 3I 30min 60min It is disabled default Auto Off function maximizes scale s battery life against people s carelessness not to power off scale when it s not working Auto Off starts countdown timer when there s no action or load is stable Any key pressing or motion in load restarts countdown timer Backlight Brightness Press O to enter Backlight Brightness h f 7 shows Press press or Ba to change brightness value Backlight Brightness can be set to oF r disabled dim normal 3 bright Page 8 of 10 High Resolution Digital Crane Scale IRIS Dim backlight brightness saves battery power dramatically Idle Mode Timing Press O to enter Idle Mode Timing di shows Press press or to change timing value Idle Mode Timing can be set to disabled 5 5 10sec 8 15sec 11 30sec 60sec It is 30sec by default To maximize battery life scale automatically enters Idle Mode when there s no action or the load is stable In Idle Mode scale works in low power consumption status Any key pressing or motion in load wakes up scale from Idle Mode Press O to exit User Setu
3. VETEK OCS 5 High Resolution Digital Crane Scale User s Guide Content SCAG 4 PRETO OD 4 5 5 Delete 7 Clear AN 7 SWIG sionis 8 Auto 8 Sis er Reed 8 ide Mode TMi ione eet ceci nete tn rto Du dez ed 9 O dn eic Ses edt deett 9 10 Troubleshooting 1 eere eere 10 Version V1 0B 1 Please read this manual carefully before using High Resolution Digital Crane Scale 1 Safety Guide For good performance and precise measurement be careful with daily operation and maintenance 009 Do NOT overload scale This will damage loadcell and void warranty Do NOT leave load hung on the scale for long This will decrease scale s accuracy and shorten loadcell s life Inspect shackle and hook before using Check clips pins and screws regularly Check battery frequently When scale runs out of power replace the dead batteries with new ones Rotate load rather than scale if needed Do NOT use scale under thunder or rain Hang scale on shelf in dry and well ventilated room Do NOT place scale on the ground directly Do NOT attempt to repair scale yourself Contact your local representative Features This scale is a combination of sound and proven mecha
4. Message Note FRIRE detect weight ot t u p User Setup Menu bh t gg battery life percentage t nd save and exit power off out overloading t invalid operation L L accumulate weight d t L delete last weight L L delete all weight 7 Operations Page 5 of 10 High Resolution Digital Crane Scale OW Power On Off Long press to power on scale Scale perform initialization and power on test shows twice then capacity shows battery percentage HAR 99 shows weight detection shows and then auto zero For information about Auto Zero refer to Scale Configuration in Technical Manual Long press or 5 to power off scale Battery life percentage h 89 shows message r shows and then cut off power When 3 batteries voltage is lower than 3 2V scale will auto power off itself Please replace the dead batteries with new ones Zero Long press Or press IT to zero shows If load is in motion or tared or out of Manual Zero Range shows For information about Manual Zero Range refer to Scale Configuration in Technical Manual Tare In Out In gross mode press or press to tare in T shows If load is in motion or negative or out of Tare Range rV shows Tare will reduce the apparent overload range of scale For example if a 500 0 2kg scale has a 100kg container as its tare the scale will overload at a new weight of 40
5. 1 8kg 500 100 additional 9 divisions Page 6 of 10 High Resolution Digital Crane Scale e e IS In net mode press press to tare out T disappears Lock Unlock Press to lock screen H shows Press O to unlock screen H disappears Accumulate Press to accumulate current weight shows indicating weight is accumulated Scale uses displayed weight so gross or net weight is added into the same accumulator If load is in motion or negative or does not return to zero before shows View Press Q to enter View mode Display flashes accumulated weight Press O to view high 5 digit or low 5 digit Press to exit View mode Delete Last Weight Press to delete last accumulated weight df shows indicating last accumulated weight is deleted Delete function only deletes the last weight If last accumulated weight has been deleted rr shows Clear Weight Press first and then press to clear all accumulated weight Page 7 of 10 High Resolution Digital Crane Scale LGN E f shows indicating all weight is cleared Unit Switch Press to switch unit in between kg lb and User Unit When unit is kg H T shows When unit is Ib L y shows When unit is User unit 1j i shows For more information about User Unit refer to Scale Configuration in Technical Manual User Setup Press first and then press
6. e dry loadcell or mainboard mainboard defective mainboard contact representative discharged battery replace battery weight reading loadcell stressed too not zero when no hang scale in storage long load loadcell drifts contact representative scale not zeroed before Manual Zero scale before applying load loading large error in switch to correct unit weight reading calibrate scale defective loadcell or contact representative mainboard Page 10 of 10 8 USER MANUAL Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com
7. nical design with today s most advanced electronics to provide a superb feature set It is versatile reliable accurate and easy to operate Superb Quality Strictly in accordance with OIML R76 Chinese GB T11883 2002 national standards and European CE directives Great Safety Aluminum casting case high firm hook and shackle dedicated weighing loadcell for safety installation Strong Reliability Cutting edge technology quality integrated Page 1 of 10 High Resolution Digital Crane Scale circuit for high performance and long time stability Broad Applicability Popular and applicable in storage textile metallurgy industry and so forth v1 Complete Function Resolution switch unit conversion auto power off battery inspection etc 3 Specifications Accuracy Chinese GB T 11883 2002 CIII eqv OIML R76 Tare Range 100 5 Zero Range 4 5 Stable Time lt 10sec Overload 100 F S 9e Safety Load 120 5 Ultimate Load 400 5 Battery 3 AA 1 5V batteries 265hour tested by dedicated batteries Battery Life backlight level 3 always lit Display 22mm 11mm HTN LCD with backlight Op Temp 10 C 40 C Op Humidity 20 C lt 90 D Capacity Modal Res Division OCS 01 S lkg 2 000 OCS 02 S 2kg 2 000 OCS 03 S 2kg 3 000 OCS 05 S 4kg 2 500 Page 2 of 10 High Resolution Digital Crane Scale 5 Dimension amp Weight
8. p Battery Maintenance To maximize battery life please note the following battery maintenance guide O This scale is powered by a 3 AA 1 5V batteries Battery house can be opened by screwing off 2 screws Depending on backlight brightness and idle mode setting normally battery works over 65 hours In order to conserve battery life enable Auto Off and Idle Mode dim backlight brightness To obtain maximum service life battery should be stored between 20 C 4 F and 50 C 122 F Stored batteries should be recharged every three months When 3 batteries voltage is lower than 3 2 scale will auto power off itself Please replace the dead batteries with new ones Page 9 of 10 High Resolution Digital Crane Scale 10 Troubleshooting Simple problems can be resolved as below listed solution If problems still exist please contact your local representative Symptom Possible Cause Suggested Solution discharged defective check battery and replace battery ot power o ress harder and kee defective On Off key E E after is pressing for 2s pressed open front panel check defective power cable power cable defective mainboard contact representative backlight flashes discharged battery replace battery no action taken scale is disturbed re plug power cable after key pressed defective key contact representative change Anti Motion level weight reading damped loadcell or not stabl