Home

PowerLogic ION7550

image

Contents

1. 300 V peak max rated voltage 120 V dc external excitation 8 inputs option Self excited internal 30 V dc supply dry DI1 DI8 contact sensing or with external excitation 1 3 to 0 1 mm2 16 to 28 AWG min pulse width 20 ms max pulse rate 25 pulses per second update rate 1 2 cycle after timing resolution Communications EtherGate and ModemGate The meters can provide gateway functionality Multiple communication ports that operate simultaneously allow the meters depending on communication options to be used as part of a power and energy management system and to EtherGate provides access from an Ethernet interface with other automation systems Upload waveforms alarms billing network Modbus TCP protocol to devices connected to the meter s serial ports Modbus protocol data and more to software for viewing and analysis ModemGate provides access from the telephone network to devices connected to the meter s Specifications serial ports Serial RS 232 RS 485 Protocols include ION Modbus RTU Modbus Master DNP 3 0 port COM 1 GPS EtherGate ModemGate Data rates 300 to 115 200 bps Duplex Full RS 232 Half RS 485 Max length RS 232 15 2 m 50 ft RS 485 1219 m 4000 ft total for entire bus eal Mavedle Serial RS 485 port Protocols include ION Modbus RTU Modbus Master DNP 3 0 Telephone COM 2 GPS EtherGate ModemGate Max length 1219 m 4000 ft total for Ethernet Serial line Serial
2. LC C Modbus RTU slavemaster Modbus tee w EtherGate ModemGate Meema WebNeter w u o onii Setpoints alarming and control Matn logic vig og nearizaion formulas w M w Call out on single amp multi condition alarms oOo u E Feat ION7550 ION7650 n A FROST SULLIVAN Metering North American Frost amp Sullivan oa Certificate No 002188 Please contact your local sales representative for ordering information Visit www powerlogic com for more information on other PowerLogic products applications and system solutions schneider Electric As standards specifications and designs develop over time always ask for 35 Rue Joseph Monier confirmation of the information given in this publication ION ION Enterprise Go 30923 Modbus and PowerLogic are either trademarks or registered trademarks of 92506 Rueil Malmaison Cedex schneider Electric All other trademarks are property of their respective owners Tel 33 0 1 41 29 70 00 www schneider electric com www powerlogic com Publishing Schneider Electric Production Schneider Electric PMC Printing Imprimerie du Pont de Claix made in France PLSED106016EN 11 2008 ART 821269 2009 Schneider Electric All rights reserved EO Printed on recycled paper
3. and demand values Screens are easily customised to suit user requirements The alohanumeric text displays are capable of supporting international labels such as OBIS and VDEW Multilingual operation can be user configured for English French Spanish or Russian Set parameter measurements via front panel to comply with regional preferences Modbus Master feature allows display of real time parameters of any downstream modbus devices Phasor Magnitude Wa 120 56 Vv who 118 21 We 122 03 W Power and energy measurements High accuracy 4 quadrant energy metering in accordance with IEC 62053 22 class 0 28 for both 3 and 2 element systems Real bidirectional reactive and apparent values Fully programmable integrating period 1 5 10 15 30 60 minutes or other 163w la 1144 050 4 Phasors display supports block rolling block and predicted demand calculations such as H Harmonics MHARE 32 kW kvar and kVA demand min max Volts and Amps demand min max eee Cumulative demand Demand on any instantaneous measurement THD Niles eh 80 tee a ng RY PERS ER EE THD Odd 20 0 nd Gad NG HERRIRA Parameter Accuracy 1 reading 4240672006 12 00 00 0 bij i i 00 00 00 Voltage line line line neutral per phase min max 0 1 unbalance Harmonic current display Trend display Frequency present min max 0 005 Hz Power real kW reactive kvar apparent kVA per phase IEC 62053 22 class 0 25
4. clock support in multiple date time formats High accuracy standards Meets stringent IEC and ANSI measurement accuracy standards such as IEC 62053 22 Class 0 25 ANSI C12 20 0 2 Class 10 amp 20 Digital fault recording simultaneously capture voltage and current channels for sub cycle disturbance transients as well as multi cycle sags swells and outages 1024 samples cycle waveform recording 20 17 us transient capture 50 60 Hz Power quality analysis and compliance monitoring A choice of THD metering individual current and voltage harmonics readings waveform capture EN50160 and IEC 61000 4 30 class A ION7650 only power quality compliance evaluation and voltage and current disturbance sag swell detection Complete communications Fiber Ethernet Serial Modem Gateway functionality simplifies communications architecture and reduces leased line or connection costs Concurrent independent ports communicate with protocols such as ION DNP 3 0 Modbus RTU Modbus TCP Modbus Master 32 concurrent Modbus TCP server connections Dial out capability when memory is near full Data push capability through SMTP email Patented ION technology Provides a modular flexible architecture that offers extensive user programmability Uniquely addresses complex monitoring and control applications Adapts to changing needs avoiding obsolescence Disturbance direction detection Determine the location of a disturbance more quickl
5. entire bus Data rates 300 to 115 200 bps Duplex Half Internal modem COM Data rates 300 bps to 56 kbps V 3 4 V 32 bis V 32 V 22 bis 3 V 22 A B V 23 V 21 Bell 212A Bell 103 Supports automatic data rate detection RJ 11 interface Approvals FCC P68 USA Industry Canada CS 03 Also approved for use in Austria Belgium Denmark Finland France Germany Greece Iceland Ireland Italy Luxembourg Netherlands Norway Portugal Spain Sweden Switzerland UK ANSI C12 18 type II Protocols include ION DNP 3 0 Modbus RTU optical port COM 4 Data rates 1200 to 19 200 bps Duplex half Ethernet port Protocols TCP IP DNP TCP ION Modbus TCP Modbus RTU Internet connectivity SMTP EtherGate SNMP Interface IEEE 802 3u 1995 and IEEE Exchange information using XML to integrate with 802 3x 1997 ISO IEC 8802 31993 Ethernet custom reporting soreadsheets databases and 10BASE T 100BASE TX connectors RJ 45 cabling Category 5 other applications or 6 unshielded twisted pair max length 100 meters 328 feet WebMeter an on board web server provides Isolation Transformer isolated to 1500 volts RMS Data rates l 10 100 Mbps Duplex full half access to real time values and PQ data through o Pe Upe a meter configuration tasks micrometer multimode fibre optic Max length 2000 m 6562 ft full duplex 400 m 1312 ft half duplex Data rates 100 Mbps MeterM il automatically emails user configured high
6. 1000 3 3 EN61000 3 3 FCC Part 15 Subpart B Class A Digital Device EN55011 CISPR 11 EN55022 CISPR 22 EN61000 6 4 EN5008 1 2 Environmental conditions Operating temperature 20 C to 70 C 4 F to 158 F no formation of ice Low Voltage DC Power Supply 20 C to 50 C 4 F 122 F Storage 40 C to 85 C 40 F to 185 F Humidity 5 to 95 non condensing Power quality Sag swell harmonics monitoring sim The 2007 award recognizes Schneider Electric for its technological advancements and wide product range in the field of power quality PQ Harmonics magnitude phase and inter harmonics f 50h and ener tiana goman solutions i total this is the fourth award that Symmetrical components zero positive negative Sennen Electric and pee aoquireg Power Measurement ae received from Frost amp Sullivan in recognition of achievements in this Recording compliant with IEC 61000 4 30ClassA arena Prithvi Raj Frost amp Sullivan research analyst osoon TY Ensor compliance checking o Transient detection microseconds 20 17 femmcoameweno Disturbance drectondetecion Logging and recording Memory standard optional 5 mB 10 mB 5 mB 10 MB Min max historical waveform logging O mE a Timestamp resolution in seconds 0 001 0 001 Hsorearrena niomatonva tonera f SPS tme syncronization RS 232 485 RS 485 Ethemet Opto T Q spon ONP E EEL
7. 61000 4 30 Class A lION7650 only monitor compliance of y p Example screen from PowerLogic ION Enterprise software showing continuous relevant parameters such as POWET frequency magnitude of supply wide area monitoring data capture and reporting for power quality and reliability voltage flicker supply voltage sags and swells transients and voltage conditions interruptions Create compliance reports using PowerLogic ION Enterprise software O Transient ION7650 only voltage waveforms of transient activity i e ITI CBEMA Type 1 disturbances Vil ab Lae a ren Data and event logging Minimum Average Maximum Forecast Minimum Forecast Average Forecast Maximum Ships with a comprehensive data logging configuration Data is prioritized and ae PVWY YY roses stored onboard in nonvolatile memory to eliminate data gaps in the event of outages aE or server downtime Retrieved data is stored in an ODBC compliant database 207 90 when using PowerLogic ION Enterprise Trending and forecasting capabilities track 207 85 specified quantities over time and forecast the value of future quantities View trending T and forecasting data through the meter s web pages Logging capacity is available 207 75 in 5 MB or 10 MB configurations Default depth and interval of logging is set at the 207 70 aa PA E SE an E factory and depends upon onboard memory size O Revenue log configured for use with UTS MV 90 billing software Logs kWh delivere
8. For electric utilities O Energy availability and reliability O Improve T amp D network reliability O Enhance substation automation to reduce field service time O Maximise the use of existing infrastructure O Revenue metering and power quality O Install new high accuracy metering at all interchange points O Improve or verify metering accuracy at existing interchange points O Verify compliance with new power quality standards O Analyse and isolate the source of power quality problems yg Financial management including accounting and billing gg Facility and energy management gg Operations management includnig engineering planning and maintenance ie E Power generation transmission and distribution O Sm Service entrances and onsite generation iia Power mitigation and main power distribution equipment ae ee ae ae PDUs and data servers Ga ew a Ge E Processes lines machines or equipment Integrated network comprising corporate intranet Internet serial dialup or wireless connections a Typical uses within a PowerLogic power and energy management system Features High visibility multilingual IEC IEEE configurable display Large backlit LCD presents multiple simultaneous real time and timestamped historical parameters as well as graphical trends and histograms Multilingual support for English French Spanish and Russian User configurable IEC or IEEE notations 12 24 hour
9. Gain energy insight and control with PowerLogic PowerLogic ION7550 ION7650 power and energy meters en ionics 10 23 2008 14 23 37 ye HARMONICS Schneider Electric avg PF sign tot 07 92 4 335 la Intelligent metering and control devices Used at key distribution points and sensitive loads the Schneider Electric PowerLogic ION7550 and ON7650 meters offer unmatched functionality including advanced power quality analysis coupled with revenue accuracy multiple communications options web compatibility and control capabilities Integrate these meters with our PowerLogic ION Enterprise software or share operations data with existing SCADA systems through multiple communication channels and protocols Typical applications For infrastructure industrials and buildings O Energy savings O Measure efficiency reveal opportunities and verify savings O Reduce peak demand surcharges O Reduce power factor penalties O Strengthen rate negotiation with energy suppliers O Enable participation in load curtailment programs e g demand response O Identify billing discrepancies O Leverage existing infrastructure capacity and avoid over building O Support proactive maintenance to prolong asset life O Energy availability and reliability O Validate that power quality complies with the energy contract O Verify the reliable operation of equipment O Improve response to power quality related problems
10. d interval kWh received interval kvarh delivered interval kKVARh received interval values 12 00 16 00 18 00 21 00 00 00 03 00 06 00 09 00 12 00 Hours Trending and forecasting as viewed from PowerLogic ION7650 web page O Historic logs record standard power system quantities such as phase current ohase voltage and power factor O Report Generator log configured to provide power system data for ION7550 ION7650 PowerLogic ION Enterprise software 500 500 Events events events events Data 1 5 years 3 1 ie 2 9 years O Trend display logs years years Multiple tariffs and time of use TOV calculations 20 year calendar with automatic leap year and seasonal time adjustments and A 16 parameters recorded every 15 minutes clock synchronization over communications channel or GPS TOU is configured four Ee arene enliel val ane a ae seasons five daily profiles per season four tariff periods per daily profile Automatic C 30 waveforms on 12 channels with any selectable format for example 6 channels are 512 samples per cycle for 4 cycles and 6 channels are 32 samples per cycle for 54 cycles mid season rate change Active reactive and apparent energy and demand automatic recording of maximum peak demand during each tariff period O Event log Inputs and outputs All models provide digital inputs as well as Form C mechanical relays and Form A solid state relays digital outputs Optional digital and analo
11. g I O is also available _ I O CARD scom S8 S7 S6 S5 S4 S3 S2 S1 All Al2 AB Al4 AO1 A02 A03 A04 Digital output relays respond to internal alarms external digital input status changes or commands over communications Use digital inputs to trigger alarms or logging synchronize to a demand pulse or control conditional energy accumulation Top view of optional 1 0 card installed showing connectors for digital inputs analog inputs and analog outputs Input output Specifications Electro 3 Form C relays 250 V ac 30 V dc max voltage 380 V ac 125 mechanical relays R1 R3 V dc Turn on time 15 ms max Turn off time 5 Form C contacts ms max Update rate 1 2 cycle or 1 second NO K NC Solid state relays 4 Form A digital Maximum voltage 30 V dc maximum current outputs D1 D4 80 mA isolation optical update rate 1 2 cycle or 1 second Analog option 4 inputs Alt to Al4 Signal type dc current range O to 20 mA scalable 4 to 20 or O to 1 mA accuracy 0 3 of full scale update rate 1 second 4 outputs AO1 to Signal type dc current range 0 to 20 mA A04 scalable 4 to 20 or 1 to 1 mA scalable O to 1 update rate cycle or 1 second 8 inputs S1 S8 Self excited using SCOM output dry contact sensing no external voltage required Min pulse width 1 ms max pulse rate 20 pulses sec Timing resolution 1 ms update rate 2 cycle after timing resolution isolation
12. ns Voltage inputs 347 direct V ac line to neutral 600 V ac direct line to line rms Withstand 2500 V ac 60 Hz for 1 minute Load burden 0 05 VA per phase at 5 A standard 0 015 VA per phase at 1 A optional Impedance 0 002 Q per phase phase Vref 0 015 Q optional current range Control power Operating range Standard 85 to 240 V ac 10 47 to 63 Hz 110 to 300 V dc 10 burden typical 15 VA max 35 VA Optional low voltage dc power supply rated inputs 20 to 60 V dc 10 burden typical 12 VA max 18 VA Optional meter current probe inputs Current probe options Meter supplied with current probe inputs configured for use with standard 0 1 V ac current probes Probes sold separately Accuracy depends on probe specs Meter supplied with current probe inputs and 3 calibrated Universal Technic 10A clamp on CTs meeting IEC 61036 accuracy Front panel Use for both display and configuration purposes The large backlit LCD display screen and the numerous selection navigation and configuration softkeys allow quick Secure access to basic meter configuration screens The front panel also provides access to many other meter functions such as meter resets and has multiple programmable screens for numeric and time stamped values frequency spectrum harmonics trend logs and name plate data The large display automatically scrolls through displays screens that present at a glance volts amps power energy
13. priority alarm notifications or scheduled system status update messages to anyone anywhere within the facility or around the world Software integration Integrate within PowerLogic facility level or enterprise wide power and energy management systems Real time data and data logs stored onboard can be automatically retrieved on a scheduled basis for analysis at the system level Compatible with PowerLogic ION Enterprise and PowerLogic ION Setup Modbus compatibility and register based logged data supports integration and data access by building automation SCADA and other third party systems Special features Flash based firmware allows upgrades via communications without removing the meter from the site Simply download the latest firmware from www powerlogic com Real time data data logs and waveforms stored on board General specifications Description Specifications Safety construction IEC 1010 1 EN61010 1 CSA C22 2 No 1010 1 UL 61010B 1 Electromagnetic Immunity IEEE C 37 90 1 1989 EN50082 2 Dielectric withstand 2500 VAC RMS at 60 Hz for 60 s Installation category III 2000m above sea level Electromagnetic IEC 61000 4 2 EN61000 4 2 IEC 8012 IEC 61000 4 3 EN61000 4 3 IEC 801 3 Radiated EM Field Immunity compatibility IEC 61000 4 4 EN61000 4 4 IEC 801 4 Electric Fast Transient IEC 61000 4 5 EN61000 4 5 IEC 801 5 Surge Immunity IEC 61000 4 6 EN61000 4 6 IEC 801 6 Conducted Immunity IEC 61000 3 2 EN61000 3 2 IEC 6
14. total Power demand kW kvar kVA Energy real kWh reactive kvarh apparent kVAh IEC 62053 22 class 0 28 rec del Power Factor at unity PF 0 2 2 1 Refer to User s Manual for valid measurement ranges 2 Refer to Compliance section Not applicable for NICT meters contact factory for measurement specifications Power quality Power quality compliance monitoring for international quality of supply standards plus specific data for localized and custom compliance agreements and network connection requirements o Harmonics all models individual harmonics up to the 63 K factor and total harmonics distortion THD o Sag Swell all models voltage waveforms for sags and swells i e ITI CBEMA Type 2 and Type 3 disturbances report on each disturbance s magnitude and duration Detect sub disturbances during a sag swell event O Disturbance direction detection all models analyse disturbance information to determine the direction of the disturbance relative to the meter Results are provided in the event log along with timestamp and the level of certainty of disturbance direction o EN50160 ION7650 with EN50160 ordering option only monitor compliance with EN50160 parameters XEFE Er mi i i wa Er wa Fa wr w mai ma E mime TE mmi ikii 1 8 Ro a a oily mina ikii en iinet tr Peary vinme J G H P PLERECOONECREURU ORR aa E o IEC
15. y and accurately by determining the direction of the disturbance relative to the meter Analysis results are captured in the event log along with a timestamp and confidence level indicating level of certainty Trending and forecasting Forecast values such as demand to better control demand charges and billing rates View results via the meter s web pages Analyse trends to support proactive maintenance schedules Transformer line loss compensation Automatically measure compensate and correct for transformer or line losses when meter is physically separated from the point of billing or change of ownership Inputs and outputs Digital and analog inputs and outputs for pulse counting demand metering for other WAGES utilities equipment status position monitoring demand synchronisation triggering conditional energy metering equipment control or interfacing Meter installation showing rear mounting clips Schneider dP Electric V3 Harmonics 10 23 2006 14 23 37 Vc HARMONICS THD 5 0 THD Even 2 0 THD Odd 2 0 Installation Designed to fit DIN standard 192 cutout 186 mm by 186 mm Circuit and control power connections include 4 wire Wye 3 wire Wye 3 wire Delta Direct Delta and single phase systems Voltage inputs include 3 phase one reference neutral and one auxiliary Three current phase inputs are provided as well as two auxiliary inputs for neutral and ground current measurement Input s Specificatio