1. LUTET T T T OR CC TTT lt lt e EAS A gt RIN X 1 Drainage device 2 Drainage pipe 3 Air flow flap 4 Connection pipe 5 Wireless Controller 6 Wired Controller 7 Big handle 8 Liquid Pipe 9 Gas pipe 10 Drainage pipe 11 Front Board Wireless Remote Controller YB1FA 1 User notice AN CAUTION Make sure there is no obstruction between the wireless remote controller and the signal receiver The signal receiving distance of the wireless remote controller can be up to 10 metres Never drop or throw the wireless remote controller Never let any liquid flow into the wireless remote controlle
2. Enter Cancel A Mode Function y Timer On Off Timer On Off Function y Timer On Off Unit On no Blow function Press Function button to set Press Enter Cancel button to blow function activate blow function SN Function y Timer On Off Timer On Off Press Enter Cancel button to Press Function button to set cancel blow function blow function Fig 22 Blow Function Setting Notes When the Blow function is activated if the unit is turned off through the On Off button the indoor fan will still run at low fan speed for another 10 minutes When the Blow function is deactivated the indoor fan will stop directly as the unit is turned off The Blow function is not available in the FAN and HEAT modes 3 17 Filter Setting Under On status press Function button to set Filter function with Filter icon flashing The setting pollution level will be shown at the Timer area Press A and Y to adjust pollution level and press Enter Cancel button to activate Filter function When the Filter function is set press Function button to set with Filter icon flashing Press A and W to adjust till OO is shown on the timer area Then press Enter Cancel button to cancel the Filter function How to set Filter function is shown in the Fig 23 19 Wired Controller XK60 Enter Cancel Enter Cancel En
3. DC Inverter Cassette Type Air Conditioner Installation and Operation Manual Do not check or repair during the unit is Do not use ther operating it is bery dangerous heating equipment near the air conditioner It will affect the cooling performance Never place objects near the air intake and the air outlet of the unit It may affect performance or stop operation of the unit Do not splash water directlu to indoor unit Do not bang the remote controller and do not It may cause trouble or electric shock press the button of the renote controller with pointed object or the remote controller may be damaged NOTE This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 1 Safety Precautions DA WARNING This mark indicates procedures which if improperly performed might lead to the death or serious injury of the user CAUTION This mark indicates procedures which if improperly performed might possibly result in personal harm to the user or damage to property 1 Installation should be left to the dealer or another professional Improper installation may cause water leakage electrical shock or fire 2 Install the air conditioner according to the instructions given in this manua
4. E HEATER option with the symbol E HEATER flashing and then press the Enter Cancel button to deactivate it E HEATER Function setting is as shown in Fig 21 Enter Cap i Y Function y Timer On Off i Timer On Off Function y Timer On Off Unit On no E heater function Press Function button to set Press Enter Cancel button to E heater function activate E heater function Enter Can s1 IN Function y Timer On Off Timer On Off Press Enter Cancel button to Press Function button to set cancel E heater function E heater function Fig 21 E HEATER Function Setting Note The E HEATER function is not available in the COOL DRY and FAN modes with the symbol E HEATER not displayed 3 16 Blow Function Setting BLOW function After the unit is turned off water in evaporator of indoor unit will be automatically evaporated to avoid mildew Activation of the Blow Function in the COOL or DRY mode press the Function button to select the Blow option with the symbol BLOW flashing and then press the Enter Cancel button to activate it 18 Wired Controller XK60 Deactivation of the Blow Function The activated Blow function can be deactivated by firstly pressing the Function button to select the Blow option and then pressing the Enter Cancel button BLOW function setting is as shown in Fig 22 aa 28 c
5. 1 2 Introduction to the LCD Icons Table 1 Icons Introduction Left and right swing function Up and down swing function O A a Health function l Demand function Vacation function mu Status display of master and slave wired controller Shield function The button operation temperature setting On Off operation Mode setting and Save setting are disabled Y Memory function The unit will resume the original setting state after power recovery mal 1 Be T m lt D AJ URBO SAVE Ambient setting temperature gt E O CD Om Wired Controller XK60 ABBR ere gt Em gt B gt E wi EJ Ea TEE aa Wired Controller XK60 2 Press Buttons 2 1 Buttons Enter Cancel 5 6 7 8 Fig 3 Press Buttons 2 2 Instruction to the Function of Press Buttons Table 2 Press Buttons Function Introduction ated ance Function selection and canceling 2 Press it for 5s to enquiry the outdoor and indoor ambient temperature Running temperature setting of indoor unit range 16 30 C 2 Timer setting range 0 5 24hr a 3 Air function setting 4 Save setting Clean setting Select fan speed from high mid high middle mid low low and auto levels Function Switchover among these functions of SWING AIR SLEEP HEALTH I DEMAND VACATION TURBO SAVE E HEATER BLOW QUIET On Off Turn on off indoor unit Press Mode and A at the same time for 5
6. button to set Press Enter Cancel button to Demand function activate I Demand function Q Function y Timer On Off h Timer On Off Press Enter Cancel button to Press Function button to set cancel I Demand function Demand function Fig 17 Demand Setting Note The Demand function can be cancelled by mode switch and unit ON OFF After the unit is resumed Demand function will be maintained The Demand function can not be simultaneously set and can be cancelled by Sleep Quiet function When the I Demand function is set the unit will run as per Auto fan speed The Turbo fan speed is not available When the I Demand function is set the setting temperature 27 C can not be changed When the setting temperature is shielded by the distant control Demand function can not be entered 3 12 Vacation Setting Vacation function It s used to keep the indoor ambient temperature and activate fast heating Under heating mode press Function button to select Vacation function with Vacation icon flashing Press Enter Cancel button to activate Vacation function When Vacation is on press Function button to set function Then press the Enter Cancel button to cancel Vacation function with no icon flashing How to set vacation function is shown in the Fig 18 ee 6 000 14 Wired Controller XK60 Enter Cangf A Mode Function A Timer
7. it will enter Enquiry interface At this time what shows on the timer area is the ambient temperature type 01 or 02 and the temperature will be shown 01 means the outdoor ambient temperature and 02 represents the indoor ambient temperature Press Mode button to switch between those two types Press any other button except Mode button or receive the signal from the remote controller will quit from the Enquiry function If there is no operation in 20s the unit will quit from this function automatically Note If the unit is not connected with the ambient temperature sensor after 12h electrification the display of the ambient temperature sensor will be shielded 2 If the outdoor temperature sensor has error after 12h electrification the display of the ambient temperature sensor will be shielded 3 20 5 Indoor fan shutdown mode setting Under unit OFF status simultaneously press Function and Timer button for 5s the wired controller will enter parameter setting interface Press Mode button to set till O5 is shown on the temperature displayed area Then the unit will enter the indoor fan shutdown mode Two options are available for the indoor fan shutdown mode Mode 1 When the temperature reaches certain value the indoor fan will not be shut down at any mode except heating mode After the unit is shut down for the duct type unit and the floor ceiling type unit the indoor fan will blow the ex
8. If press either of them continuously the setting time will automatically increase decrease by 0 5hr every 0 5s Notes 1 When Timer On and Timer Off both are set the displayed time is the Timer On setting for the unit under the OFF state or is the timer Off setting for the unit under the ON state Timer On setting starts when the unit under the ON state is turned off Timer Off setting starts when the unit under the OFF state is turned on 3 8 Air Exchange Setting How to activate the air exchange function Under the ON state of the unit press the Function button to select the AIR function with the function symbol flashing and then press A or Y to adjust the AIR type after that press the Enter Cancel button to activate this function When this function is activated the symbol will be displayed Type 1 is the defaulted AIR type There are 10 AIR function types but only 1 2 types are for the wireless remote controller Wired Controller XK60 1 The unit continuously runs for 60min and fresh air valve runs for 6 min 2 The unit continuously runs for 60min and fresh air valve runs for 12 min 3 The unit continuously runs for 60min and fresh air valve runs for 18 min 4 The unit continuously runs for 60min and fresh air valve runs for 2 4 min 5 The unit continuously runs for 60min and fresh air valve runs for 30 min 6 The unit continuously runs for 60min
9. On Off Timer On Off Function v Timer On Off Unit On no Vacation function Press Function button to set Press Enter Cancel button to vacation function activate vacation function S Function y Timer On Off 1 Timer On Off Press Enter Cancel button to Press Function button to set cancel vacation function vacation function Fig 18 Vacation Setting Note The vacation function can be only set under heating mode The turbo function will be cancelled when the vacation function is set 3 The Sleep and Quiet function will be cancelled when the vacation function is set 4 After the unit is resumed the vacation function will be maintained 65 When the vacation function is set the setting temperature can not be shielded by the distant control In reverse the vacation function can not be set when the distant shielding is taking into effect When the vacation function is set the setting temperature shown on the wired controller is 8 C The indoor fan will automatically run as per Auto fan speed The vacation function can be cancelled when there is mode switching The temperature will go back to the original setting temperature prior to vacation function Unit ON OFF will not cancel the vacation function 3 13 Turbo Function Setting TURBO function The unit at the highest fan speed can realize quick cooling or heating so that room temperature can quickly approach the setting temper
10. the Ultra Dry function is activated it can be cancelled by pressing A button or pressing Mode button to switch mode 3 20 Other Functions 3 20 1 Lock Function Under the ON state of the unit without any malfunction or under the OFF state of the unit press A and Wbuttons at the same time for 5s till the wired controller enters the lock state In this case LCD displays F After that repress these two buttons at the same time for 5s to quit the lock state Under the lock state no response will be given to the other button operation 22 Wired Controller XK60 3 20 2 Memory Function Memory switchover Under the OFF state of the unit press the Mode and A buttons at the same time for 5s to switch memory modes When setting the memory mode MEMORY will be displayed If this function is deactivated the unit will go to the OFF state after power recovery Memory recovery If the memory function is On the wired controller after power failure will resume its original running state upon power recovery Note It will take about 5 seconds to save data Therefore please do not cut down the power at this time or data will fail to be saved 3 20 3 Selection of Centigrade and Fahrenheit Under the OFF state of the unit press the Mode and Y buttons at the same time for 5s Centigrade and Fahrenheit scales will be switched alternately 3 20 4 Ambient Temperature Enquiry Under On Off status press Confirm button for 5s
11. the guide louver swings up and down among those five button directions Simplified SWING function applicable for some Fan Coil Units When the wireless remote controller is energized initially with the unit under the OFF status it should be set by pressing the button and the SWING button simultaneously with the symbol blinking twice Then after the unit is turned on this function can be activated by pressing the SWING button with the displayed symbol A indicating swing function is on and without this displayed symbol indicating swing function is off By pressing this button the clock is allowed to be set with O blinking and then press the button to adjust the clock within 5 seconds If the button is pressed down constantly for more than 2 seconds the clock setting will be increased or decreased 10 minutes every 0 5 seconds After that another press on the CLOCK button accepts the setting 12 00 is the default when the wireless remote controller is energized When TIMER ON is activated ON will blink while the symbol will disappear Within 5 seconds it is allowed to set the ON time by pressing the button Each press will make the time increase or decrease one minute Besides the time can also be set by pressing the button TIMER ON constantly that is in the early 2 5 seconds the time will increase button decrease quickly per single minute and in the late 2 5 the time will increase decrease per ten minut
12. 0 aaaea faae ea emmma toeea aeea j ON 1 Nu NO 4 5 6 7 8 9 10 11 12 Time hour Fig 14 Sleep Curve under the COOL Mode Under the Heat mode the Sleep function is ON the setting temperature range can be 16 C 17 20 C 21 27 C or 28 30 C Each of them has a different curve as shown in Fig 15 e g If the setting temperature is 22 C the temperature will drop by 1 C in each hour until it reaches 20 C Then the unit will run at this temperature 5 t t H i i t t i i i t t t t t t 4 1 t t t 5 t i t t H i i t t t t t t M H 1 I t t t t H t t 0 i 5 t i i i t t 1 t t t 1 t t H t i i i i t t 1 t t i ij 4 t 5 6 7 8 9 10 11 12 Time hour Fig 15 Sleep Curve under the HEAT Mode Wired Controller XK60 3 10 Health Setting Under unit on status press Function button to select health function with Health icon flashing Press Enter Cancel button to activate health functi
13. Install the Wired Controller First of all the selection and connecting method of the communication line is shown as follows 1 Select appropriate communication line of the wired controller 2 core signal line wire size gt 0 75mm length lt 30m recommended length 8m 2 After the indoor unit is de energized fix the communication line on the indoor terminal board by screws Then the specific installation steps is shown in the Fig 27 Fig 27 Installation of the Wired Controller Wired Controller XK60 Brief instructions Pull out the 2 core signal line from the mounting hole and pass this line through the round hole located at the bottom of the wired controller 2 Use M4x25 screws to fix the soleplate of the wired controller on the wall 3 Fix the signal line on the copper tabs X1 and X2 Make sure the line is tightly fixed and with no short circuit potential 4 Set the panel and the bottom together by clasps 4 4 How to Remove the Wired Controller The wired controller can be easily removed as shown in Fig 28 Fig 28 Removal of the Wired Controller 5 Error Display When error happens to the unit the error code will be shown on the wired controller When multiple errors simultaneously happen the error codes will circularly show up When error occurs please immediately shut down the unit and contact professional personnel As shown in the Fig 29 means the high pressure protection Enter Ca
14. OFF button indoor fan will continue running for severval minutes at low speed In this period press X FAN button to stop indoor fan directly With X FAN function OFF After turning off the unit by pressing ON OFF button the complete unit will be off directly e About TURBO function This function is applicable to some special models If the TURBO function is activated the unit will run at high fan speed to perform cooling or 4 Wireless Remote Controller YB1FA heating quickly so that the ambient temperature will approach the preset temperature as soon as possible e About lock Press and buttons simultaneously to lock or unlock the keyboard If the wireless remote controller is locked the icon A will be displayed on it in which case any press will get no response but with the mark blinking for three times If the keyboard is unlocked the mark will disappear e About SWING UP DOWN Press the Swing Up Down button for more than 2 seconds and then the louvre will swing up and down After releasing the button the louvre will stop swinging and keep the current status When the louvre starts swinging by pressing the Swing Up Down button 2 seconds later the louvre will stop swinging directly while by pressing the Swing Up Down button within 2 seconds the louver will keep swinging e About Change over switch between Fahrenheit and Centigrade Under the OFF state of the unit press MODE and buttons simultaneously to switch be
15. Saving Setting for Cooling When the unit runs under the COOL or DRY mode press the Function button to select the SAVE function option with SAVE flashing and then press A or Y to adjust the lower limit after that press the Enter Cancel button to activate this function 2 Energy Saving Setting for Heating When the unit runs under the HEAT mode press the Function button to select the SAVE function option with SAVING flashing then press the Mode button to switch to the SAVE setting for the HEAT mode and then press A or Y to adjust the upper limit after that press the Enter 16 Wired Controller XK60 Cancel button to activate this function The activated SAVE function can be deactivated by firstly pressing the Function button to select the SAVE option and then pressing the Enter Cancel button The energy saving setting is as shown in the Fig 20 Function y Timer On Off Timer On Off Function v Timer On Off Unit On no Save function Press Function button to set Press A or W button to energy saving temperature for adjust temperature Cooling Enter C cel N Function y Timer On Off Function Timer On Off Function y Timer On Off Press Enter Cance button to Press A or W button to Press Mode button to set activate save function adjust temperature energy saving temperature for Heating Fig 20 SAVE Function
16. Setting Notes 1 Under the Auto mode when the SAVE function is activated the unit will forcibly quit the Auto mode and change to the current operation mode Further the Sleep function will be deactivated when the SAVE function is activated 2 During the SAVE setting if the Function button is pressed down or there is not any operation within 5s after the last button operation the system will quit the SAVE setting with the current setting data not saved The SAVE function setting will be memorized in case of power failure The lower limit for cooling is 16 C and the upper limit for heating is 30 C During the SAVE setting if the expected setting temperature is out of the limit then the limit temperature always prevail 17 Wired Controller XK60 3 15 E HEATER Setting E HEATER in the HEAT mode E HEATER function is allowed to be activated to improve the heating efficiency Generally it will be activated automatically as the unit goes into the HEAT mode through any button operations Activation of the E HEATER Function firstly press the Function button to select the E HEATER option with the symbol E HEATER flashing and then press the Enter Cancel button to activate it After the activation the symbol E HEATER will always be displayed Deactivation of the E HEATER Function firstly press the Function button to select the
17. USER S MANUAL SINCLAIR AIR CONDITIONING Original instructions DC Inverter Cassette Type Air Conditioner Installation and Operation Manual Read the following carefully to assure safe use Avoid direct air flow to your body and avoid excessive heating or cooling which may make you feel uncomfortable and do harm to your health Do not remove protection grill nets from the outdoor unit Do not reach hands or insert anything into the unit air outlet If there is something abnormal eg burning smell cut off the power immeditely and con tact service center If room air is stuffy air the room by opening door and window for a while but please close the curtains when operating the unit to pre vent conditioned air from leaking Warning Check whether the installed stand 1s still firm enough after the unit has operated for a long time If a worn out stand ls left unfixed the unit may topple and do harm Do not stand on the outdoor unit or put anything on it or you may fall down or people may get hurt by the falling things Do not spray any paint or pesticide on the unit or it may cause fire f Never use wrong ampere rating wire Use of iron wire or copper wire may cause the unit to break down or cause fire a ER i iron wire gt NOTE Children should be supervised to ensure that they do not play with the appliance
18. and fresh air valve runs for 36 min 7 The unit continuously runs for 60min and fresh air valve runs for 42 min 8 The unit continuously runs for 60min and fresh air valve runs for 48 min 9 The unit continuously runs for 60min and fresh air valve runs for 54 min 10 The unit continuously runs for 60min and fresh air valve always runs How to deactivate the air exchange function When the Air function is activated it can be deactivated in the way by firstly pressing the Function button to select the Air function option with the Air symbol flashing and then pressing the Enter Cancel button with the Air symbol disappeared Air Exchange setting is shown as in Fig 12 Enter Cancel Enter incel Function v Timer On Off Timer On Off Function y Timer On Off Unit On no Air function Press Function button to set Press A or W button to air function adjust air mode Enter C ncel Enter incel A Y v Function y Timer On Off Enter Sancel Timer On Off Function v Timer On Off Press Enter Cancel button Press Function button to Press Enter Cancel button to to cancel air function set air function activate air function Fig 12 Air Exchange Setting 10 Wired Controller XK60 3 9 Sleep Setting Sleep on Press the Function button under the ON state of the unit to select the Sleep function option and the
19. ange Table12 Indoor Side Outdoor Side Test Condition DB C WB C DB C Nominal Cooling Nominal Heating Note The design of this unit conforms to the requirements of EN14511 standard 2 The air volume is measured at the relevant standard external static pressure 3 Cooling heating capacity stated above is measured under nominal working conditions corresponding to standard external static pressure The parameters are subject to change with the improvement of products in which case the values on nameplate shall prevail 4 In this table there are two outside DB values under the low temp cooling conditions and the one in the brackets is for the unit which can operate at extreme low temperature 7 Troubleshooting and Maintenance 7 1 Troubleshooting If your air conditioning unit suffers from abnormal operation or failure please first check the following points before repair Table 13 Failure Possible Reasons The power supply is not connected Electrical leakage of air conditioning unit causes tripping of the leakage The unit cannot be started switch The operating keys are locked The control loop has failure There is obstacle in front of the condenser The unit operates for a The control loop is abnormal while and then stops Cooling operation is selected when the outdoor ambient temperature is above 48 C The air filter is dirty or blocked There is heat source or too many peop
20. ature In the COOL or HEAT mode press the Function button to select the Turbo function option and then press the Enter Cancel button to activate it When the Turbo function is activated it can be deactivated by firstly pressing the Function 15 Wired Controller XK60 button to select the Turbo option and then pressing the Enter Cancel button Turbo function setting is as shown in Fig 19 Enter Q ncel A Y Function v Timer On Off Function y Timer On Off Timer On Off Unit On no Turbo function Press Function button to set Press Enter Cancel button to turbo function activate turbo function Enter Q incel Ny Function y Timer On Off Timer On Off Press Enter Cancel button to Press Function button to set cancel turbo function turbo function Fig 19 Turbo Function Setting Notes 1 The Turbo function will not be deactivated due to power failure In DRY FAN and AUTO modes the Turbo function is unavailable and the function symbol won t be displayed 2 The Turbo function will be automatically deactivated as the Quiet function is activated 3 The FAN button can also be used to adjust Turbo function 3 14 SAVE Function Setting Energy Saving Function Energy saving can make the air conditioner runs in a smaller temperature range by setting lower limited value of setting temperature in the COOL or DRY mode and upper limited value in the HEAT mode 1 Energy
21. covers over the wires Incomplete cover installation may cause terminal overheating electrical shock or fire 10 If any refrigerant has leaked out during the installation work ventilate the room The refrigerant produces a toxic gas if exposed to flames 11 After all installation is complete check to make sure that no refrigerant is leaking out The refrigerant produces a toxic gas if exposed to flames 12 When installing or relocating the system be sure to keep the refrigerant circuit free from substances other than the specified refrigerant R410A such as air Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture resulting in injury 13 During pump down stop the compressor before removing the refrigerant piping If the compressor is still running and the stop valve is open during pump down air will be sucked in when the refrigerant piping is removed causing abnormal pressure in the freezer cycle which will lead to breakage and even injury 14 During installation attach the refrigerant piping securely before running the compressor If the compressor is not attached and the stop valve is open during pump down air will be sucked in when the compressor is run causing abnormal pressure in the freezer cycle which will lead to breakage and even injury 15 Be sure to establish an earth Do not earth the unit to a utility pipe arrester or telep
22. een 4 Disassemble the air purifier Remove the air purifier after removing the fixed screws on it Support Filtering element Bolt 5 Clean the filer screen Clean the filer screen by a vacuum cleaner or wash it by flashing water If the oil stain on the filter can not be removed or cleaned up wash it by warm water meld with the detergent Dry the filer in the shadow Note Never use hot water over 45 C in case of color fading or turning yellow Never dry it by fire so as to prevent the filter caught fire or deformation 6 Reset the filer The same as step 3 7 Install the grille well The same as step 1 and 2 32 DC Inverter Cassette Type Air Conditioner Installation and Operation Manual 10 Optimum Operation Adjust the room temperature properly Adjust the room temperature properly for a comfortable environment Water may drop from the indoor unit when the humidity is over 80 or when the drainage outlet is clogged When the main power switch is truned on some watts of electricity is being used even if the system is not operating Turn off the main power supply switch to save energy Do not open the doors and windows for a long time when air conditioner is operating Cooling and heating performance will be affected if the doors and windows are open for a long time SSN a Place TV radio stereo etc at least 1m away from the indoor unit and the remote controller It may cause interference l
23. es After the desired time value is set press TIENE ON again to conform the setting within five seconds After that another press on TIMER ON will cancel the setting Prior to this setting the clock shall be set to the actual time Pressing this button can activate or deactivate the X FAN function In Cool or Dry mode by pressing this button if cb is displayed it X FAN indicates the X FAN function is activated By repressing this button button if cio disappears it indicates the X FAN function is deactivated After energization X FAN OFF is defaulted If the unit is turned off X FAN can be deactivated but can t be activated Wireless Remote Controller YB1FA By pressing this button it is allowed to select displaying the indoor setting temperature or the indoor ambient temperature Indoor setting temperature is default after the indoor unit is energized initially By pressing the TEMP button when the temperature symbol ry IS displayed the indoor displayer will show the indoor setting temperature when ny is displayed it will show the indoor ambient temperature when AL is invalidation If current displays indoor ambient temperature if received the other remote control signal it will display presetting temperature 5s later will back to display the ambient temperature This function is applicable to partial of models By pessing this button it is available to go to the TIMER OFF settting state with the same setting
24. eventing potential negative impacts to environment and human health which could be consequence of incorrect disposal of waste Ask for more details from local authorities nearest collection point in Waste Acts of respective country in the Czech Republic in Act no 185 2001 Coll in the wording of later regulations In case of incorrect disposal of this waste a fine can be imposed according to national regulations a K Manufacturer Sinclair Corporation Ltd 1 4 Argyll Street London W1F 7LD UK Supplier and technical support Nepa spol s r o Purkynova 45 612 00 Brno Czech Republic www hnepa Ccz Toll free info line 420 800 100 285 CE
25. hing powder liquid insecticide which may cause discoloring or warping If the air flow flap is very dirty you may remove it to clean as shown below Detach the flap Loosen the screws on the sides of the flap clean with soft cloth Fix the flap Set the ribs on the sides of the air outlet to the slit of the flap and then screw together to fix the flap 1 Check to make sure no objects obstructing the intake and outlets parts on both the indoor and outdoor units 2 Check to make sure ground wire is connected and that it is not damaged 3 Check to make sure air filter has been cleaned 4 Turn on the power 6 hours before starting the air conditioner 1 Clean the filter and the body of the unit 2 Turn off power Shut off 3 Clear outdoor unit of dust power 4 If there is any rust in the outdoor unit this should be painted over to prevent the rust from spreading Operate on unmentioned buttons would not impact on the normal use Take back of electrical waste Information for Users to Disposal of electrical and electronic equipment private households Icon on the product or in the accompanying documentation means that used electric or electronic products must not be disposed together with domestic waste For the correct disposal of the product hand it over to a place for take back where it is collected free of charge By correct disposal of the product you can help to preserve valuable natural resources and help in pr
26. hone earth Incomplete earth may cause electrical shock or fire A high surge current from lightning or other sources may cause damage to the air conditioner 16 Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric shocks or fire 17 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 18 Children should be supervised to ensure that they do not play with the appliance 19 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 1 Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage If the gas leaks and builds up around the unit it may catch fire 2 Establish drain piping according to the instructions of this manual Inadequate piping may cause flooding 3 Tighten the flare nut according to the specified method such as with a torque wrench If the flare nut is tightened too hard the flare nut may crack after a long time and cause refrigerant leakage 2 Outline of the Unit and Main Parts Indoor Air outlet E LI g K Outdoor Air inlet o
27. ilter function is when the function is set with icon flashing let 00 shown at the timer area at this time the accumulated time will be zero clearing 3 18 Quiet Function Setting Press Function button to set Quiet function with its icon flashing Press Enter Cancel button to activate Quiet function When the quiet function is On press Function button to set with Quiet icon flashing press Enter Cancel button to cancel Quiet function How to set Quiet function is set in the Fig 24 Wired Controller XK60 Enter Cancel A NS Function y Timer On Off A Timer On Off Function y Timer On Off Unit On no Quiet function Press Function button to set Press Enter Cance button to quiet function activate quiet function Vv Enter Cancel N Function y Timer On Off Press Enter Cancel button to Press Function button to set cancel quiet function quiet function Enter Cancel A vy Timer On Off Fig 24 Quiet function setting Notes QUIET function is unavailable in Fan or Dry mode Owing to power failure the Quiet function is defaulted to be deactivated If quite function is set turbo function will be canceled 3 19 Ultra Dry Setting Under Dry mode when the setting temperature is 16 C press W button twice and the setting temperature will be changed to 12 C at this time the unit enters the Ultra Dry function When
28. ing unit e Preset temperature can be decreased by pressing this button Pressing and holding this button for more than 2 seconds can make the temperature changed quickly until release this button and then transmit this order The temperature adjustment is unavailable under the Auto mode but the order can be sent by pressing this button Centigrade setting range 16 30 button Fahrenheit scale setting range 61 86 Preset temperature can be increased by pressing this button Pressing and holding this button for more than 2 seconds can make the temperature changed quickly until release the button and then transimit this order The temperature adjustment is unavailable under the Auto mode but the order can be sent by pressing this button Centigrade setting range 16 30 Fahrenheit scale setting range 61 86 button By pressing this button Auto Low Middle High speed can be circularly selected After power on Auto fan speed is default FANbutton Low speed _aa Middle speed i High speed Note Under the DRY mode the fan will be kept running at the low speed and the fan speed isn t adjustable Wireless Remote Controller YB1FA e Press this button to set up the swing angle which circularly changes as below A a gt gt Jl ETETE e When the guide louver starts to swing up and down if SWING funtions is canceled the air guide louver will stop and remains at the current SWING position UP DOWN A indicates
29. ioner with the filter uninstalled otherwise dust would come into the unit Do not remove the air filter except for cleaning Unnecessary handling may damage the filter 3 Do not clean the unit with gasolene benzene thinner polishing powder or liquid insecticide otherwise it would cause discoloration and deformation of the unit Do not wet the indoor unit in case of electric shock or fire hazard Increase the frequency of cleaning if the unit is installed in a room where the air is extremely contaminated As a yardstick for yourself consider cleaning the filter once a half year If dirt becomes impossible to clean change the air filter How to clean the air filter 1 Open the air inlet grille 1 How to open the panel grille of the 24K 42K cassette type unit Push the buckle as shown in the figure Release the screws under buckles by a screwdriver Push the fastener and open the panel grille Push the fastener How to open the panel grille of the 12K 18K 48K 60K cassette type unit Remove the screws by a screwdriver as shown in the picture Push those two fasteners and open the panel grille 2 Disassemble the air inlet grille Open the air inlet grille at 45 raise it and remove the grille TS 1 SJ 3 Disassemble the filter screen 7 Te i i AL Draw out the filter screen and remove it Mi FI J i Filter scr
30. l Incomplete installation may cause water leakage electrical shock or fire 3 Be sure to use the supplied or specified installation parts Use of other parts may cause the unit to come to lose water leakage electrical shock or fire 4 Install the air conditioner on a solid base that can support the weight of the unit An inadequate base or incomplete installation may cause injury in the event the unit falls off the base 5 Electrical work should be carried out in accordance with the installation manual and the national electrical wiring rules or code of practice Insufficient capacity or incomplete electrical work may cause electrical shock or fire 6 Be sure to use a dedicated power circuit Never use a power supply shared by another appliance 7 For wiring use a cable length enough to cover the entire distance with no connection Do not use an extension cord Do not put other loads on the power supply use a dedicated power circuit Failure to do so may cause abnormal heat electric shock or fire 8 Use the specified types of wires for electrical connections between the indoor and outdoor units Firmly clamp the interconnecting wires so their terminals receive no external stresses Incomplete connections or clamping may cause terminal overheating or fire 9 After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels Install
31. le inside the room The door or window is open Poor cooling effect There is obstacle at the air intake or outlet The set temperature is too high There is refrigerant leakage The performance of room temperature sensor becomes worse The air filter is dirty or blocked The door or window is not firmly closed The set room temperature is too low Poor heating effect There is refrigerant leakage The outdoor ambient temperature is lower than 5 C Control loop is abnormal Note After carrying out the check of the above items and taking relevant measures to solve the problems but the air conditioning unit still does not function well please stop the operation of the unit immediately and contact the local service agency designated by Sinclair Ltd Only ask professional serviceman to check and repair the unit DC Inverter Cassette Type Air Conditioner Installation and Operation Manual The following are not troubles The unit does not operate when Mist is emitted Outdoor unit is hot Dust from the units Wind from the outlet smells 7 2 Routine Maintenance Only a qualified service person is allowed to perform maintenance Before accessing to terminal devices all power supply circuits must be disconnected Do not use water or air of 50 C or higher for cleaning air filters and outside panels Notes Do not operate the air condit
32. method as that of the TIMER ON in which OFF button case the OFF symbol blinks this function will be canceled automatically This function is applicable to In the Cool or Heat mode pressing this button can activate or deactivate TURBO the TURBO function When the TURBO fucntion is activated its symbol uici will be displayed when the running mode or the fan speed is changed partial of models By pressing this button Sleep On and Sleep Off can be selected After SLEEP powered on Sleep Off is defaulted Once the unit is turned off the Sleep button function is canceled When Sleep is set to On the symbol of SLEEP G will display Under the Fan and Auto modes this function is not available Press this button to select LIGHT on or off in the displayer When the LIGHT LIGHT is set to on the icon XK will be displayed and the indicating light button in the displayer will be on When the LIGHT is set to off the icon XK will be disappeared and the indicating light in the displayer will be off 3 Introduction for special function e About X FAN function This function is applicable to some special models This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould This function indicates that moisture in the evaporator of the indoor unit will be blew out after the unit is stopped so as to avoid mould With X FAN function ON After turning off the unit by pressing ON
33. n press the Enter Cancel button to activate it Sleep off When the Sleep function is activated press the Function button to select the Sleep function option and then press the Enter Cancel button to deactivate this function Sleep setting is as shown in Fig 13 Enter C cel Y Function v Timer On Off Function v Timer On Off Timer On Off Unit On no Sleep function Press Function button to set Press Enter Cancel button to sleep function activate sleep function Enter Cz cel IN Function vy Timer On Off Timer On Off Press Enter Cancel button to Press Function button to cancel sleep function set sleep function Fig 13 Sleep Setting Notes The Sleep function is defaulted to be OFF after power recovery The Sleep function is unavailable under the Fan mode When the Quiet function is activated the Quiet function will always keep ON no matter if the Sleep function is activated or deactivated Under the Cool mode the Sleep function is ON the setting temperature range can be 16 23 C 24 27 C 28 29 C or 30 C Each of them has a different curve as shown in Fig 14 6 0600 11 Wired Controller XK60 e g If the setting temperature is 25 C the temperature will rise by 1 C in each hour until it reaches 27 C 7 hours later the temperature will drop to 26 C After that the unit will run at this temperature i FT py E tavema
34. n the picture or sound It may do harm to them DC Inverter Cassette Type Air Conditioner Installation and Operation Manual 11 Care and Maintenance It should be done by professionals Pull out the power plug before cleaning E Do not splash water directly to the unit Screws 1 Open the suction grille Use screwdriver screws the two screws a eS Slide both knobs simultaneously as shown and then pull them downward slowly Ww f i 2 Remove the air filters Slide knobs on the back of the suction grille outward and remove the air filter Then remove three air cleaners on it 3 Clean the air filter Use vacuum or wash the air filter with water when the air filter is very dirty use neutral detergent and water Let the filter dry naturally at shady place Note Do not clean with hot water Do not dry over fire Do not run the air conditioner without the air filter DC Inverter Cassette Type Air Conditioner Installation and Operation Manual 4 F1x the air filters e Fix three air cleaner on the air filter and then fix the air filter to the suction grille by hanging it to the projected portion above suction grille e Set air filter by sliding the knob on the back of the Pu Ao Sy Go RI suction grille inward SS BES BSS Shut the suction grille Refer to step 1 How to clean the suction grille 1 Open the suction grille See step 1 of How to clean the air filter 2 Remo
35. ncel A Function y Timer On Off Fig 29 26 Wired Controller XK60 Error codes and their meanings Table 5 Compressor high pressure protection Indoor anti freeze protection refrigerant colleting mode a E a S Fo ____trdooranbinttonporaturesonsoreror 8 Caper temperatiresersoreror ep st Ps Communication ener between main contaland arive Wired Controller XK60 3 a Oa o a as m ea P o s8 e Instructions to the Error Indicating Lamps on the Panel of the Cassette Type Unit 88 Dispaly Auto Button Receiver Timer Power ey Indicating Lamp Indicating Lamp Test Button Fig 46 Power and ON OFF Indicating Lamp It goes red when the unit is powered on while it goes white when the unit is started Timer Indicating Lamp It goes on when the timer is set and goes off when it is not Its display is in yellow 38 Display When there is no error and it receives valid remote control information It will display the temp setup for 5s then display the temp of indoor When the unit has error It will display the error code When there are more than one error the error code will be displayed alternately After the grille of the front panel is opened the front panel is still allowed to realize the following functions by pressing the Auto button and the nearby Test button simultaneously for five seconds when the unit is Off 6 2 Working Temperature R
36. ng hour reaches 1400h Every increase of the number means another 400h is accumulated When 9 shows up it means the operating hour reaches 5000h When the filter reaches serious level pollution 3 will be shown at the first place When 0 shows up at the second place the accumulated operating hour reaches 100h Every increase of the number means another 100h is accumulated When 9 shows up it means the operating hour reaches 1000h Pollution level with corresponding operating hour Table 3 Pollution Accumulated operating Pollution Accumulated operating Pollution Accumulated operating level time h level time h level time h Note 1 If the Filter function is effectively set the icon will light up If it is not necessary to clean the filter no matter whether the setting is changed or not the unit will not restart to timing while pressing Enter Cancel button 8 If the filter should be cleaned under On OFF status the icon will blink once every 0 5s so as to remind user to clean the filter Press Function button to set with icon flashing Press A and y to adjust pollution level and then press Enter Cancel button to activate it If the setting pollution level is lighter than before the icon will keep flashing If the setting pollution level is more serious the icon will go out and the Filter function will keep on working 4 The only method to cancel F
37. on When health is on press Function button to set function with health icon flashing Then press the Enter Cancel button to cancel health function How to set health function is shown in the Fig 16 Enter Caf el Y Function y Timer On Off Timer On Off Function y Timer On Off Unit On no Health function Press Function button to Press Enter Cancel button to set health function activate health function Enter Ce el X Function y Timer On Off Timer On Off Press Enter Cancel button to Press Function button to set cancel health function health function Fig 16 Health Setting Note The health function can be cancelled by turning off the unit The health function can not be cancelled by mode switching After the unit is resumed health function will be maintained 3 11 Demand Setting Under cooling mode press Function button to select Demand function with l Demand icon flashing Press Enter Cancel button to activate Demand function When Demand is on press Function button to set function with l Demand icon flashing Then press the Enter Cancel button to cancel I Demand function How to set Demand function is shown in the Fig 17 13 Wired Controller XK60 S Function v Timer On Off l Timer On Off F netion y Mimer TONo Unit On no l Demand function Press Function
38. property loss due to parameter changed by customers 4 Installation of the Wired Controller 4 1 Standard Parts 4 Table 4 Standard Parts O 0 Fig 26 Standard Parts of the Wired Controller 24 Wired Controller XK60 4 2 Installation Location and Installation Requirements 1 Do not install the wired controller in the damp place or under direct sunlight 2 Do not install the wired controller close to the hi temperature object or place where the wired controller is likely to suffer water spray 3 Do not install the wired controller directly opposite to the window so as to avoid improper operation caused by the interference of the neighbor s same model wired controller 4 Please cut off the power supply of wires embedded in the wall No operation is allowed with electricity 5 To avoid abnormal operation caused by electromagnetic interference or other causes please take notice of the following statements during wiring Be sure the communication line is wired into the correct port otherwise it would result in communication fault 2 The communication line wired controller and power line must be separated with the minimal distance of 20cm otherwise it would result in communication fault 3 Suppose that the air conditioner is installed where likely to suffer electromagnetic interference the communication line of the wired controller must be shielded twisted pair 4 3 How to
39. r Never expose the wireless remote controller under the sunlight directly or where it is very is a general remote control it could be used for multiple types functions of air conditioners For some models without the functions specified here we preserve the right to not to inform exclusively 2 Control panel of the wireless remote controller Note This remote controller is universal and can be used for multi functional air conditioning If the button on the remote controller with the function which the air conditioner doesn t have is pressed the unit remains in its original operating mode E 88 80 TIMER OFF SABIDO oO 6860 Wireless Remote Controller YB1FA No Name Function Description anal midi e Signal transmitter transmitter e Press this button and the unit will be turned on press it once more and the ON OFF a i unit will be turned off When turning off the unit the Sleep function will be button a cut canceled but the presetting time is still remained e By pressing this button Auto Cool Dry Fan Heat mode can be selected circularly Auto mode is default after power on Under the Auto mode the setting temperature will not be displayed Under the Heat mode the initial MODE value is 28 C 82 F Under other modes the initial value is 25 C 77 F button ir Gia wea de NAUTO SE COOL DRY a FAN X HEAT only for cooling and heat
40. s under the OFF state of the unit to activate deactivate memory function If memory is set indoor unit will resume original setting state after power recovery If not indoor unit is defaulted to be OFF after power recovery Memory function is defaulted to be ON Under the ON state of the unit without any malfunction or under the OFF state of the unit press Aand Y buttons at the same time for 5s to go to the lock state In this case any other buttons won t respond the press Repress A and Y again for 5s to quit the lock state Under the OFF state of the unit press the Mode and Y at the same time for 5s to switch the temperature scale between Celsius and Fahrenheit Fan Wired Controller XK60 3 OPERATION INSTRUCTION 3 1 On off Press the On Off button to turn on or off the unit Notes The state shown in Fig 4 indicates the OFF state of the unit after energization 2 The state shown in Fig 5 indicates the ON state of the unit after energization Enter Cancel Enter Cancel Function y Timer On Off Function v Timer On Off Fig 4 OFF State of the Unit Fig 5 ON State of the Unit 3 2 Mode Setting Under the ON state of the unit press the Mode button to switch the operation modes as the sequence shown in Fig 6 m gt Cooling gt oe Enter Cancel Function Timer On Off Wired Controller XK60 3 3 Temperature Setting Press A or Wbutton to increase or decrease setting temperature under on s
41. swing function Enter Sancel A y Timer On Off Fig 9 Right and Left Swing Setting Wired Controller XK60 3 6 Up and Down Swing Under the ON state of unit press the Function button to select the Up and Down Swing function option and then press the Enter Cancel to activate it When the Swing function is activated press the Function button to select the Up and Down Swing function option and then press the Enter Cancel button to deactivate it Up and Down Swing function setting is as shown in Fig 10 Enter Cancel A Enter ancel A Enter ancel A Ny Function v Timer On Off v Timer On Off Function v Timer On Off Unit On no up down swing Press Function button to set Press Enter Cancel button to up down swing function activate up down swing function Enter ancel Y Function y Timer On Off Timer On Off Press Enter Cancel button to Press Function button to set cancel up down swing function up down swing function Fig 10 Up and Down Swing Setting 3 7 Timer Setting Timer On Setting It is intended to set when to start the unit When the unit is OFF press the Timer button with xx Hour displayed and ON blinking then press A to adjust the timer after that press the Timer button again to make a confirmation If the Mode button is pressed prior to the confirmation it will switch to the Timer Off setting After the timer Off setting the LCD displays
42. tate of the unit If press either of them continuously temperature will be increased or decreased by 1 C every 0 5s In Cooling Dry Fan and Heating mode temperature setting range is 16 C 30 C In Auto mode the setting temperature is un adjustable As shown in Fig 7 Function y Timer On Off Fig 7 Temperature Setting 3 4 Fan Speed Setting Press Fan button fan speed of indoor unit will change as the sequence shown in Fig 8 gt iow gt ats aan Fi Enter Cancel Function vy Timer On Off Fig 8 Fan Speed Setting 6 Wired Controller XK60 3 5 Right and Left Swing Under the ON state of unit press the Function button to select the Right and Left Swing function option and then press the Enter Cancel button to activate it When the Swing function is activated press the Function button to select the Right and Left Swing function option and then press the Enter Cancel button to deactivate it Right and Left Swing function setting is as shown in Fig 9 Enter Cancel Enter cancel Enter Cancel Y Function y Timer On Off z Timer On Off Function y Timer On Off Unit On no left right swing Press Function button to set Press Enter Cancel button to left right swing function activate left right swing function Enter Cancel Y Function y Timer On Off Press Enter Cancel button to Press Function button to set cancel left right swing function left right
43. ter Cancel Y Function y Timer On Off Timer On Off Function v Timer On Off Unit On no Filter function Press Function button to set Press A or W button to set filter function the pollution level AUTO Enter Cancel Enter Cancel Enter Cancal Function v Timer On Off Timer On Off Function y Timer On Off Press A or W button to set Press Function button to set Press Enter Cancel button 00 shown at the timer area filter function to activate filter function Enter Cana A Ny Function y Timer On Off Press Enter Cancel button to cancel filter function Fig 23 Filter Setting While setting Filter two numbers will be shown on the timer area The first number represents the pollution level The second number shows the accumulated operating time of the indoor fan There are four statuses in total No Filter function setting 00 shown at the timer area When the filter reaches light level pollution 1 will be shown at the first place When 0 shows up at the second place the accumulated operating hour reaches 5500h Every increase of the number means another 500h is accumulated When 9 shows up it means the operating hour reaches 10000h 3 When the filter reaches middle level pollution 2 will be shown at the first place When 20 Wired Controller XK60 0 shows up at the second place the accumulated operati
44. tra heat for 60s and then stop running For the cassette type unit its indoor fan will operate at low fan speed and blow the extra heat for 60s only when error happens to it Mode 2 No matter the unit is under which mode the indoor fan will keep running for 10s after the temperature reaches certain value then it will stop Press A or Y button to adjust the mode Under Mode 1 2 00 01 will show up in the timer area Then press Enter Cancel button to save the settings The setting procedures are shown as Fig 25 23 Wired Controller XK60 Enter Cancel Mode Enter Cancel Enter Cancel Function y Timer On Off i On Off Function v Timer On Off Unit off Simultaneously press Function Press Mode button to set till and Timer button for 5s the 05 is shown on the temperature wired controller will enter displayed area Then the unit will parameter setting interface enter the indoor fan shutdown mode Enter Cangf Enter Cancel Function y Timer On Off Function Timer On Off Press Enter Cancel button to Press A or W button to save the settings and quit from adjust the mode the interface Fig 25 Indoor fan shutdown mode setting Note In the parameter setting interface only when 05 shown on it the indoor fan shutdown mode can be set Other parameters are not allowed to be modified and our company is not responsible for the unit damage or
45. tween C and F 4 Replacement of batteries dll along the arrowhead direction and push the back cover of O Slightly press the place with the wireless remote controller Take out the used batteries Insert two new AAA 1 5V dry cell batteries and pay attention to their polarity Put back the cover of the wireless remote controller OPEN AN Notes When changing the batteries do not use the used or different type batteries otherwise it would cause some malfunction to the wireless remote controller If the wireless remote controller will not be used for a long time please take them out and don t let the battery liquid damage the wireless remote controller The operation should be within the signal receiving range 4 It should be placed 1m away from the TV set or stereo sound sets If the wireless remote controller can not operate normally please take batteries out for 30s If the anomaly persists please change them The battery must be removed from the appliance before it is scrapped The batteries is to be disposed of safely Wired Controller XK60 1 Introduction to the Wired Controller AUTO TURBO Cl A OC I F x 2 Zeh a E IC a B88 Enter Cancel A Function y Timer On Off Fig 1 Appearance of the Wired Controller 1 1 Appearance and LCD Icons 1 2 34 5 6 7 8 9 1011 12 13 14 15 16 1718 19 20 21 22232425 26 27 Fig 2 Appearance of the LCD Wired Controller XK60
46. ve the air filters See step 2 of How to clean the air filter 3 Remove the suction grille Open the suction grille at 45 and then lift 4 Wash with water eis When the suction grille is very dirty use soft HAHH brush and neutral detergent Shake off water and dry in a shady place Notes Do not wash with hot water 5 Fix the suction grille Refer to step 3 6 Fix the air filter See step 4 of How to clean the air filter 7 Close the suction grille Refer to step 1 DC Inverter Cassette Type Air Conditioner Installation and Operation Manual 1 Open the suction grille See step 1 of How to clean the air filter 2 Remove the air cleaner Remove the air filter and remove the air cleaner after unscrewing 3 Take off packing bag and put in new static electricity fiber filter then fix them on the air filter SR SS O SSA lt V SIS Y US AS a SOS a 4 Fix the air filter See step 4 of How to clean the air filter e Absorbs bad smell in air such as carbon monoxide carbon dioxide benzol gasoline and so on e Absorbs harmful objects bigger than 1 0 um in air such as dust flower power germ virus and so on e It can be used for about half a year to one year DC Inverter Cassette Type Air Conditioner Installation and Operation Manual How to clean the air outlet and case e Clean with soft cloth of use water and neutral detergent e Do not use gasoline benzene thinner polis
47. xx Hour ON OFF xx Hour indicating the time to start the unit while the time to stop the unit won t be displayed Timer Off Setting It is intended to set when to stop the unit When the unit is On press the Timer button with xx Hour displayed and OFF blinking then press A Wto adjust the timer after that press the Timer button again to make a confirmation If the Mode button is pressed prior to the confirmation it will switch to the Timer On setting After the timer On setting the LCD displays xx Hour ON OFF xx Hour indicating the time to stop the unit while the time to start the unit won t be displayed 8 Wired Controller XK60 Cancellation of Timer Setting The timer setting can be canceled by press Timer Then xx Hour won t be displayed Timer Setting under the ON state of the Unit is as shown in Fig 11 Enter Cancel A Function y Timer On Off ime On Off Function Timer On Off Unit On no timer function Press Timer button to set Press A or W button to timer off adjust timer time JO L LI c On Off Function Timer On Off Function y Timer On Off Press timer button to activate Press A or W button to Press Mode button to set timer function adjust timer time timer on Fig 11 Timer Setting under the ON state of the Unit Timer range 0 5 24hr Every press of the A or Y button will make the setting time increased or decreased by 0 5hr
Download Pdf Manuals
Related Search
Related Contents
ASUS UX305FA User's Manual Toshiba Satellite S55t-A5334 Descargar - General IR518 Thermal Imager User Manual User's Manual - EPS Bio Technology Corp. Ⅰ.ハムスターに必要な二つの生活環境 ①【地下の生活 McIntosh CS100 loudspeaker Yamaha PORTATONE PSR-E403 User's Manual Panasonic ET-PKD510S project mount Copyright © All rights reserved.