1. SD 2 TD 2 subtitle teletext decoder user manual Table of Contents IE EMF ONE E E E E 4 1 1 The SD 2 TD 2 Product LR 4 1 2 Applications for the SD 2 TD 2 eeii nnne 5 1 3 Associated Equipment for the SD 2 TD 2 eeeeeeeeeeeeeee 5 TEE ERE ET UU UU T T TUM 6 1 32 G70 9 feo Br ES EE TETTE 6 ZA aree RR m 8 2 1 Installation of the SD 2 TD 2 product 8 2 2 Installing the SD 2 TD 2 into a flexiBox sees 8 2 3 Connecting Video to an SD 2 TD 2 n 8 2 4 Connecting Panels to the SD 2 TD 2 eese 9 Oe AU OW NR RE 10 3 1 Manual control of the SD 2 TD 2 ccecccccccceccseeeceeeeecseeeseeeeseeeeseaes 10 3 2 Automation Control of the SD 2 TD 2 ert r LEE LEE LEER ES 10 3 3 Operational Menus for the SD 2 TD 2 eeeseeeeeeeneen 11 AO CHIC AR DDO TDR ane a TTSMT 16 4 1 Technical Specification for the SD 2 TD 2 eres 16 4 2 Jumpering the I BUS CAN BUS Termination 16 ae eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Table of Figures Figure 1 SD 2 TD 2 MOQOUIG simsii nn senc diner Ere epos 4 Figure 2 Decoded subtitles displayed on a monitor 5 Figure 1 3 flexiBox with flexiPanel fitted E kk r ner 6 Figure 1 4
2. FP 10 desktop modular panel 6 Figure 1 5 FP 9 1RU modular panel 7 Figure 2 1 Connections for a SD 2 TD 2 module showing internal links 8 Figure 2 2 I Bus Connections and Termination 9 Figure 4 1 Location Of I Bus Termination Link 17 3 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com System Overview This manual describes the function of the SD 2 TD 2 This unit decodes and displays the subtitle teletext information embedded in a SDI Video Stream Ll The SD 2 TD 2 Product The SD 2 TD 2 are units that will decode the subtitle teletext signal embedded in a video signal and display the information overlaid onto the screen The main features are as follows Page number of subtitle teletext is selectable Q Subtitle teletext information can be viewed as large or small text The level of the subtitle teletext overlay display can be faded up or down and its position on the video image user set to make the video image more easily viewable a o 19 0120 0900 Figure 1 SD 2 TD 2 Module a eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com L
3. TD 2 can be done using two protocol methods geNETics Automation Protocol Q PresTX Automation Protocol Genetics protocol is described in detail in the GeNETics User Guide section titled Automation Protocol on the geNETics Platform The menu list in section 3 of this chapter contains the data information for the protocol Pres TX Automation Protocol is used only for the PresTX Presentation Mixer and channel branding system In this case an AU 2 Automation card is also required Refer to the PresTX Product manual JO eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 3 Operational Menus for the SD 2 TD 2 Menus 00 03 SD 2 Menus 00 03 TD 2 Menus 04 07 SD 2 Menus 04 07 TD 2 Menu Num Heading Automation Function Stitle T Text On Off Pressing this will toggle turning the Subtitle Tele Text display on or off Dsplay Default is 5 Fader 0 100 The intensity of the overlaid text display 100 is full on and 0 turns the Il eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Level Default is overlay off 100 6 Page 0 999 The selects the teletext page number to display subtitles are us
4. been ordered separately we assume here that you already have a flexiBox system with a Flexipanel and that the flexiBox has a spare slot above for the SD 2 TD 2 card 2 2 Installing the SD 2 TD 2 into a flexiBox To install the SD 2 TD 2 into a flexiBox it is desirable but not necessary to power down the flexiBox Follow these instructions On the rear of the flexiBox are 6 slots for Products Remove a spare blanking plate There are 2 off M2 5 Screws which require unfastening for each blanking plate Slide the Product PCB into the spare slot and firmly push it home Use the two thumbscrews to fasten the unit in place Now refer to the GeNETics User Guide If your system consists of a single flexiBox with a single flexiPanel then refer to the section titled flexiPanel Auto Set up If your system is part of a network with more than one flexiPanel then refer to the section titled flexiPanel Manual Set up This will guide you through acquiring your product as a device on the flexiPanel 2 3 Connecting Video to an SD 2 TD 2 A Typical Connection diagram for the SD 2 TD 2 is shown below All signals are SDI SD 2 Processor OP NC NC NC H _ gt i oO El hy Uu y i E k a Figure 2 1 Connections for a SD 2 TD 2 module showing internal links 8 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 4
5. 4 0 1923 256 100 email eesales eyeheight com The SD 2 TD 2 Modules have a number of user configurable jumpers which can change the function of the 5 SDI BNC Connectors These jumpers are found close to the BNC Connectors 2 4 Connecting Panels to the SD 2 TD 2 The SD 2 TD 2 may be operated using a FP 9 Flexipanel locally mounted For a more operational environment the SD 2 TD 2 may be supplied with a desk mounting FP 10 unit For detailed information on connecting remote panels refer to the section Connection of Remote Panels to a flexiBox in the geNE Tics Hardware Installation Guide Below is shown a typical system consisting of an SD 2 DT 2 in a flexiBox controlled by a remote FP 9 Connect Pins 1 2 4 7 9 from chassis to panels 1 1 Use twisted pair AES Digital Audio cable for pins 2 and 7 Pins 1 4 9 carry power 0 5 Amp 13V Use cable with a least a 1 amp rating for pins 1 4 9 Cable llength should not exceed 250m I Bus pins 2 amp 7 The I BUS Network requires terminating with 100 Ohms at each extreme end of the network Ensure that this is done either by an external 100 ohm resistor OR ONE Panel Product at each end has the termination set See the Genetics User Guide Under the sections Flexipanel Power I BUS Jumpers For the 4RU Panels see 4RU Panel FP 10 Jumpers for I BUS and 4RU Panel VP 10 SW 10 AP 10 Jumpers for I BUS Alternatively The termination can be set on a Product ie the MW 2 m
6. actory fitted aoe ad ea x SR Figure 1 3 flexiBox with flexiPanel fitted 1 3 2 Control Surfaces Q flexiPanel is a IRU control surface that fits on the Front of a 1RU flexiBox The order code is FP 9 A FlexiPanel can also be used in conjunction with a miniBox in this case the extra accessory Order code RR 9 will be required Q FP 10 is a desk mounting control surface Order code FP 10 This unit is a modular unit which can be used in conjunction with the units below eyeheight Le Fp10 Figure 1 4 FP 10 desktop modular panel E a eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com eyeheight Figure 1 5 FP 9 1RU modular panel 7 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 2 Installation 2 1 Installation of the SD 2 TD 2 product If this unit is already pre installed in a flexiBox FB 9 or a maxiBox with either a local or a remote panel from the factory then refer to the Hardware Installation Guide which will be enclosed with the system If this unit is pre installed in a miniBox MB 9 then also refer to the Hardware Installation Guide which will be enclosed with the system If this unit has
7. e Applications for the SD 2 TD 2 Applications for the SD 2 TD 2 include the following Monitoring subtitle information embedded within a SDI video stream Viewing teletext pages embedded in a SDI video stream t stay sober Figure 2 Decoded subtitles displayed on a monitor 3 Associated Equipment for the SD 2 TD 2 Hardware Requirements The SD 2 TD 2 are modules and require both a chassis and a control surface to function For example if the user required three subtitle decoders in a 1RU Chassis then the recommended requirements would be 3 off SD 2 Modules 1 off FB 9 Flexi box 1 off FP 9 Flexipanel 5 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Software Requirements There are no special software requirements The system is controlled via the front panel however it may be alternatively controlled by an automation system connected to the I Bus via a DG 9 Eyeheight Dongle 1 3 1 Chassis Types flexiBox is a 1RU chassis The order code is FB 9 This will hold a maximum of 6 SD 2 TD 2 Modules with Hot Swap redundant PSU option and Hot Swap SD 2 TD 2 modules Q maxiBox is an alternative low cost 1RU chassis The order code is MX 9 This also will hold a maximum of 6 SD 2 TD 2 modules but it has no redundant PSU option and the SD 2 TD 2 units must be f
8. ight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 4 Technical Appendix 4 1 Technical Specification for the SD 2 TD 2 Number of Inputs 1 Type of Inputs 2 0Mbit Serial Digital Video Inputs 75 Ohm Line Length At least 200 Meters of PSF 1 8 Typically 275 Meters Number of Outputs 3 Output BNC s per Card Configurable Type Of Outputs 2 0Mbit Serial Digital Video Outputs 75 Ohm 800mV Total Number Of 5 consisting of 1 Fixed Input and 3 Jumper BNC Connections Configurable outputs One BNC not used SDI Output Jitter The system will add less than 0 2UI to the input Jitter This is only guaranteed on issue 2 or later cards Current Consumption lt 800mA at 5V 4 2 Jumpering the I BUS CAN BUS Termination The I BUS Network is the control system under which all Products and Panels are networked together Under certain circumstances it is necessary to terminate the network This can be done on a Panel or a Product To terminate this product locate J6 on the SD 2 TD 2 Processor Card supplied which is between U1 The large square chip and the Edge connector This is on the half of the card labelled CHP 100 Spartan2 Processor Jumper this with a 2mm link l6 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Tele
9. odule Information about this is given in this manual Figure 2 2 I Bus Connections and Termination 9 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 Operation 3 1 Manual control of the SD 2 TD 2 Manual Control of the SD 2 TD 2 is done using one or more of the following control surfaces The 1RU FP 9 Flexipanel The FP10 Desk mounting Panel The FP 9 and the FP 10 have identical manual control systems The FP 10 is simply a desktop version of the FP 9 The SD 2 TD 2 are as are all genetics modules controlled using a set of MENUS Each of these menus contains up to 3 parameters that are adjusted using the rotary digipots The Menus define all of the adjustable operational parameters in the SD 2 TD 2 Pressing the rotary digipots brings the parameter to its default value Device selection is done using the device select switches which when pressed will offer the name of the device in the LCD Window Modules can be acquired and then de acquired using the set up switch For a full description of the operation philosophy of the geNETics system refer to the geNETics User Guide section Operation of the flexiPanel A full list of the Menus and their functions are given in section 3 of this chapter 3 2 Automation Control of the SD 2 TD 2 Automation control of the SD 2
10. phone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com s EX trail 5 TEE Fy EEE OUTLET EDIT a i 7 i T F e zt Ti LE I ee fe MANS P EN ae SESE i Ri LI ni Mit IM Ta EM ad d E TETT filen d 3 roe T i ig A LCL ENERET NE KEN Anp te tenants r pre Wo Jr imum LEA d u mna T nt pi Iir asta ee la 4 m ad aim Lo 4 tie RE 5 LT H at gos liii a I a T 2 E T E d E on 7 gt jj r JE X f A t a ps er 1 ni r mat 3 ie 8 ae Ja n zd 1H008H8A 3 c Figure 4 1 Location Of l Bus Termination Link 17 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com
11. recall Memory number 1 User Names can be Variable 1 programmed in to the memories using a keyboard See geNETics User guide section Giving product Memories names 17 MEM2 1 Recall Pressing this will recall Memory number 2 Variable 1 18 MEM3 1 Recall Pressing this will recall Memory number 3 Variable 1 19 MEM4 1 Recall Pressing this will recall Memory number 4 Variable 1 Menu 20 23 SD 2 TD 2 Menu Heading Automation Function x Save 1 Save Pressing this will Save Memory Mem 1 number 1 Variable 1 4 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 21 Save 1 Save Pressing this will Save Memory Mem 2 number 2 Variable 1 22 Save 1 Save Pressing this will Save Memory Mem 3 number 3 Variable 1 23 Back 1 Save Pressing this will Save Memory number 4 Variable 1 Menu 24 27 SD 2 TD 2 d P Heading Automation Function oet As 1 save Pressing this will save the current Pow On set up as the power on default Memory Variable 1 25 Recall 1 Recall Pressing this will recall the power on Pow On default settings Memory variable 1 26 TOTAL 1 Reset Pressing this will reset the system RESET Variable 1 27 Software N A Shows the current software version Version 15 eyehe
12. ually found on number Default is page 888 888 7 System On Off Pressing this will toggle turning the Ident system Ident bar on or off Default is Off Menus 08 11 SD 2 TD 2 Menu Num Heading Automation Function Text H 0 2 This sets the horizontal size of the text size Default is 1 Text V 0 1 This sets the vertical size of the text size Default is 0 9 10 Block H 0 999 This sets the horizontal position of the posn overlay screen on the video image Default is 15 n Block V 0 999 This sets the vertical position of the of the posn overlay screen on the video image Default is 65 l2 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 12 15 SD 2 TD 2 Menu Num Heading Automation Function Language 0 12 This sets the language of the text Default is 1 0 Default 1 English 2 German 3 Swedish 4 Italian 5 French 6 Portugese 7 Czech 8 Polish 9 Turkish 10 Serbian 11 Estonian 12 Lettish I eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 16 19 SD 2 TD 2 Menu Heading Automation Function MEM 1 1 Recall Pressing this will