Home
Fluke Networks Fluke Networks MS2
Contents
1. DTX CableAnalyzer Ordering Information DTX 18001 DTX 1800 CableAnalyzer Includes DTX 1800 Main and Smart Remote LinkWare PC Software 128MB MMC Card Cat 6A Class EA Permanent Link Adapters 2 Cat 6 Class E Channel Adapters 2 Headsets for Talk 2 AC Chargers 2 Carrying Case USB Interface Cable Mini B Serial RS 232 Cable IEEE 1394 to DB 9 User Manual DTX 12001 DTX 1200 CableAnalyzer Includes DTX 1200 Main and Smart Remote LinkWare PC Software Cat 6A Class EA Permanent Link Adapters 2 Cat 6 Class E Channel Adapters 2 Headsets for Talk 2 AC Chargers 2 Carrying Case USB Interface Cable Mini B User Manual DTX LT 1 DTX LT CableAnalyzer Includes DTX LT Main and Smart Remote LinkWare PC Software Cat 6A Class EA Permanent Link Adapters 2 2 Cat 6 Class E Channel Adapter 1 AC Chargers Carrying Case USB Interface Cable Mini B User Manual DTX MFM2 DTX Multimode Fiber Modules Includes two modules one for Main and one for Smart Remote 850nm and 1300nm LED sources combined into single output port 850 1300 1310 1550 nm power meter and integrated VFL DTX SFM 2 DTX Singlemode Fiber Modules Includes a set of two modules for Main and Smart Remote 1310nm and 1550 nm laser sources combined into single output port 850 1300 1310 1550 nm power meter and integrated VFL DTX 1800 M DTX 1800 with Multimode Fiber Modules Includes DTX 1800 CableAnalyzer and a set of DTX MFM2 M
2. different cabling types or fiber optic cabling contact Fluke Networks Cat 6A Class EA permanent link adapters Plug type shielded Cat 6A centered 8 pin modular plug RJ45 Plug life gt 8000 insertions Tests supported shielded and unshielded cable TIA Cat 3 4 5 5e and 6 and ISO IEC Class C D and EA permanent link Cat 6 Class E channel adapters Plug type shielded 8 pin modular socket RJ45 Plug life gt 10 000 insertions Tests supported shielded and unshielded cable TIA Cat 3 4 5 5e 6 and 6A and ISO IEC Class C D EA channels TIA Category 3 and Category 5e per TIA EIA 568B Category 5 1000BASE T per TIA TSB 95 Category 6 per TIA EIA 568B 2 1 Addendum 1 to TIA EIA 568B 2 Category 6A per TIA EIA 568B 2 10 ISO IEC 11801 Class C D and E 11801 2000 Class C D and E 11801 Amd 1 Class EA channel Amd 2 Class EA permanent link 11801 Class F DTX 1800 only EN 50173 Class C D E 50173 Class F DTX 1800 only ANSI TP PMD IEEE 802 3 10BASE T 100BASE TX 1000BASE T 10GBASE T IEEE 802 5 STP cabling IBM Type 1 150 Q Token Ring 4 Mbps and 16 Mbps Speed of Autotest Full 2 way Autotest of Category 6 Twisted Pair links 9 seconds or less Full 2 way Autotest of ISO IEC Class F links 25 seconds Supported test parameters Wire Map Length Propagation Delay Delay Skew DC Loop Resistance Insertion Loss Attenution Return Loss RL RL Remote NEXT NEXT Remote Attenuation to Crosstalk R
3. Cat 6 Class E Channel Adapters set of 2 DTX GG45 Nexans GG45 Adapter Kit available July 2009 Includes GG45 Channel Adapters 2 and GG45 Permanent Link Adapters 2 DTX PLA002 Cat 6A Class EA Permanent Link Adapter with centered Cat 6A DTX AXTERM Link Terminator for Alien Crosstalk Measurements set of 2 Class EA plug one adapter also used to test Cat 6 Cat 5e and Cat 5 links with 8 pin modular jacks DTX PLA002S DTX PLAOO2S Cat 6A Class EA Permanent Link Adapter with cen DTX LION Lithium Ion Battery Pack tered Cat 6A Class EA plug also used to test Cat 6 Cat 5e and Cat 5 links with 8 pin modular jacks set of two DTX PLA001 Cat 6 Class E Permanent Link Adapter DTX SER Serial RS232 Cable IEEE 1394 to DB 9 DTX PLA001S Cat 6 Class E Permanent Link Adapters set of 2 with DSP PM06 DSP MCR U MultiMedia Card MMC Reader USB DSP PM06 Cat 6 Centered Personality Module set of 2 to be used with DTX LinkWare LinkWare Cable Test Management Software Free download at PLAOO1 adapters www flukenetworks com linkware DSP PMxx Personality Modules for IDC and Legacy Cabling Systems A wide LinkWare LinkWare Stats Statistical Report Option Results analysis variety of modules are available for IDC type connectors and legacy Stats software option for LinkWare systems to be used with DTX PLA001 adapters DTX CHAO11 Siemon Tera Channel Adapter DTX 1218E DTX 1200 Enhancement Kit Upgrade DTX 1200 to D
4. TX 1800 DTX PLAO11 Siemon Tera Permanent Link Adapter DTX LT18E DTX LT Enhancement Kit Upgrade DTX LT to DTX 1800 DTX LT12E DTX LT Enhancement Kit Upgrade DTX LT to DTX 1200 Support Options GLD DTX DTX Gold Support Includes no charge repair loaner kit no charge scheduled annual calibration or performance verification no charge replacement of accessories no charge software or firmware upgrades unlimited 7x24 multilingual technical support unlimited access to KnowledgeBase and on line training 20 discount on all in person or on site training programs priority access to the used equipment list and members only discounts on select products and enhancements GLD DTX FIBERMOD DTX Fiber Module Gold Support Same above 1 Available in 120V and International 120 240V versions 120V v version n includes English users rs manual International version includes multi language pack users manual a Th nun na alitu madulac na ana naie af intarfaen adantare and ana nair Shop for Fluke Networks products at S ho p FI ukeNetworkS a 1 877 766 5412 DTX CableAnalyzer Series Specifications Shielded and unshielded twisted pair LAN cabling TIA Category 3 4 5 5e and 6A 100 Q STP FTP SSTP and UTP ISO IEC Class C and D 100 Q and 120 Q ISO IEC Class E Class EA Class F and Class FA 100 Q Note For availability of additional adapters that allow testing to other performance standards
5. atio ACR N The selected test standard determines the test parameters Remote ARC from the far end ACR F formerly named ELFEXT ACR F Remote Power Sum NEXT and the frequency range of the tests PS NEXT PSNEXT Remote Power Sum ACR N PSACR Remote Power Sum ACR F PS ACR F and PS ACR F Remote Cable tone generator Generates tones that can be detected by a tone probe such as a Fluke Networks IntelliTone probe The tones are generated on all pairs Frequency range of tones 440 Hz to 831 Hz Display 3 7 in 9 4 cm diagonal 240 dots wide by 320 dots high passive color transmissive LCD with backlight Input protection Protected against continuous telco voltages and 100 mA over current Occasional ISDN over voltages will not cause damage Case High impact plastic with shock absorbing overmold Dimensions Main unit and Smart Remote 8 5 in x 4 4 in x 2 4 in 21 6 cm x 11 2 cm x 6 cm nominal Weight 2 4 lb 1 1 kg nominal without adapter or module Power Main unit and remote Lithium ion battery pack 7 4 V 4000 mAh Typical battery life 12 to 14 hours Charge time with tester off 4 hours below 40 C AC adapter charger USA version Linear power supply Input 108 V ac to 132 V ac 60 Hz Output 15 V dc 1 2 A AC adapter charger international version Switching power supply Input 90 V ac to 264 V ac 47 to 63 Hz Output 15 V dc 1 2 A isolated output Memory backup power in main
6. gories DTX CableAnalyzer far exceeds Level IIIe requirements of TIA EIA 568 B 2 10 and IEC 61935 1 Class F link test modes DTX 1800 is compliant with Level IV requirements as in the draft 2nd edition of IEC 61935 1 Length for Twisted Pair Cabling 1 2 ns 4 751 to 4000 ns Parameter Single ended test Dual ended test Main and Remote Range 4000 ns 150 m 490 ft Resolution ins 0 1 m or 1 ft Accuracy 2 ns 2 0 to 750 ns 2 ns 2 Propagation Delay Parameter Single ended test Dual ended test Main and Remote Range 4000 ns 750 ns Resolution 1ns 1ns Accuracy 2 ns 2 0 to 750 ns 2 ns 2 2 ns 4 751 to 4000 ns Delay Skew Parameter Twisted Pair Cabling Range 0 ns to 100 ns Resolution 1ns Accuracy 10 ns DC Loop Resistance Test Parameter Twisted Pair Cabling Range 0 Q to 53 Q Resolution 0 10 Accuracy 10 1 Less than 10 minutes to rated accuracy following over voltage Referencing is required after Overload recovery time repeated or prolonged over voltage NETWORK VISION Fluke Corporation P O Box 777 Everett WA USA 98206 0777 Fluke Networks operates in more than 50 countries worldwide To find your local office contact details go to www flukenetworks com contact Note all specifications for tests on twisted pair cabling apply to 100 Q cable Contact Fluke Networks for information on measure
7. ment performance for cable with a different impedance t Length specs do not include the uncertainty of the cable s NVP Value Above specifications are subject to change without notice 2009 Fluke Corporation All rights reserved Printed in U S A 7 2009 2131195C B ENG N Shop for Fluke Networks products a SRO p FlukeNetworkS ca 1 877 766 5412
8. ultimode Fiber Modules DTX 1800 MS DTX 1800 with Multimode and Singlemode Fiber Modules Includes DTX 1800 CableAnalyzer and set of DTX MFM Multimode Fiber Modules and DTX SFM2 Singlemode Fiber Modules DTX 1200 M DTX 1200 with Multimode Fiber Modules Includes DTX 1200 CableAnalyzer with set of DTX MFM2 Multimode Fiber Modules DTX 1200 MS DTX 1200 with Multimode and Singlemode Fiber Modules Includes DTX 1200 CableAnalyzer and set of DTX MFM2 Multimode Fiber Modules and DTX SFM2 Singlemode Fiber Modules DTX 1800 SR DTX 1800 Smart Remote Add on DTX 1200 SR DTX 1200 Smart Remote Add on DTX LT SR DTX LT Smart Remote Add on Accessories and Options DTX NSM Network Service Module for DTX Series 1 Link identifier 2 DTX CHA012 Nexans GG45 Channel Adapter Link connectivity check port characteristics of active device ping function and 3 Power over Ethernet POE verification of voltage and polarity for 802 3af DTX AXKIT Alien Crosstalk Kit for DTX Series Test and certify alien crosstalk DTX TERA Siemon Tera Adapter Kit Includes Tera Channel Adapters 2 performance with DTX 1800 Contains DTX AXTLK1 Communication and Tera Permanent Link Adapters 2 Modules set of 2 Windows based AxTALK Analyzer Software link ter minators DTX AXTERM set of 2 and RJ45 to RJ45 coupler set of 2 DTX CHA001A Cat 6 Class E Channel Adapter DTX PLA012 Nexans GG45 Permanent Link Adapter available July 2009 DTX CHA001SA
9. unit Lithium battery Typical life of lithium battery 5 years Languages supported English French German Spanish Portuguese Italian Japanese and Simplified Chinese Calibration Service center calibration period is 1 year The battery will not charge at temperatures outside of 0 C to 45 C 32 F to 113 F The battery charges at a reduced rate between 40 C and 45 C 104 F and 113 F Shop for Fluke Networks products at S h O p FI u ke N etwo rkS ca 1 8 71 1 66 54 12 Operating temperature 32 F to 104 F 0 C to 45 C Storage temperature 4 F to 140 F 20 C to 60 C Operating relative humidity RH without condensation 32 F to 95 F 0 C to 35 C 0 to 90 95 F to 113 F 35 C to 45 C 0 to 70 Vibration Random 2 g 5 Hz 500 Hz Shock 1 m drop test with and without module and adapter attached Safety CSA C22 2 No 1010 1 1992 EN 61010 1 1st Edition Amendments 1 2 Pollution degree Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 Safety of Information Technology Equipment 1999 Altitude Operating 4000 m Storage 12000 m EMC Baseline accuracy EN 61326 1 The baseline accuracy of all DTX Series testers meets or exceeds the requirements of Level IV as in draft 2nd Edition of IEC 61935 1 over the frequency range supported by the tester Category 6A Class EA link test modes and lower link cate