1. If such a location does not exist SpecWare will prompt you before creating it If the station logger is connected directly it is easiest to se lect the lt Direct Connect 2000 Series gt entry in the list For remote connections such as wireless select the station s entry that was set up previously Configuring a 2000 Series Weather Station with the Key pad It is possible to deploy a weather station Model 2900 ET 2700 and 2550 without configuring it with SoecWare See the WatchDog 2000 Series Weather Stations User s Guide for details 11 WARRANTY This product is warranted to be free from defects in material or work manship for one year from the date of purchase During the warranty period Spectrum will at its option either repair or replace products that prove to be defective This warranty does not cover damage due to improper installation or use lightning negligence accident or unau thorized modifications or to incidental or consequential damages be yond the Spectrum product Before returning a failed unit you must obtain a Returned Materials Authorization RMA from Spec trum Spectrum is not responsible for any package that is returned without a valid RMA number or for the loss of the package by any ship ping company Spectrum Technologies Inc 3600 Thayer Court Aurora IL 60504 800 248 8873 or 815 436 4440 Fax 815 436 4460 E Mail info specmeters com www specmeters com 12 Rev 03 201
2. prompt to Select Install Type click on Complete and then Next Follow the screen instructions to complete the installation A desktop icon and a Start menu entry for SpecWare will be created The program can also be run by clicking on the Spec9Pro exe or Spec9Basic exe file in the C SpecWare directory Upgrading From Prior Versions If you have a prior version of SpecWare already installed on a given computer it is recommended that SpecWare be installed in the same directory as the existing version Multiple versions of SoecWare can co exist without interfering with one another Data files from SpecWare versions 6 or earlier must be imported into the current version of SoecWare before they can be viewed and manipulated SpecWare cannot convert current format SpecWare data files to a format compatible with earlier versions SPECWARE DIRECTORY The SpecWare directory is created during the installation process The default location of this directory is usually C SpecWare or wherever SpecWare has been previously installed The SpecWare directory contains the program s executable file as well as other support files The SpecWare directory is also where logger and weather station data is saved Data are stored in sub directories of the SpecWare directory usually referred to as Logger Locations Upon installation SpecWare will create a sub directory called SPECDEMO This sub directory contains sample data and allows new users to try out Sp
3. 3
4. SpecWare 9 Pro and Basic Software Quick Start Guide Item s 3654P9 3654P9U 3654P9X 3654B9 3654B9U 3654B9X Spec 9 Pro or vatchDog Pr Pr oducts gs Inds Plainfield il 60585 8 8873 Pepel Technologies Inc CONTENTS Installation SpecWare Directory Viewing Data Default Settings Testing the Com Port Data Loggers ON OO FP FP OW WatchDog Manager Spectrum Technologies Inc SpecWare Software 1997 2012 Spectrum Technologies Inc For support or to place an order call Spectrum Technologies Inc Bredevoortsestraatweg 101 7121 BE Aalten the Netherlands phone 31 543 472334 Email info specmeters eu 2 Thank you for purchasing SpecWare software Several manuals including the full User Manual Disease Model Man ual and Advanced Features Manual are included as pdf files on the installation CD and during software installation will be installed in your SpecWare folder These can be easily ac cessed via the Help menu in SpecWare Adobe Reader or Foxit Reader available free from www adobe com or www foxitsoftware com respectively is required to view these documents This Quick Start guide serves as a resource for some of the most commonly encountered features of the software INSTALLATION Insert the SpecWare installation CD in your computer s disk drive On most machines the software installation will begin automatically If it does not run the Setup exe program on the CD When
5. ecWare s graph and report fea tures VIEWING DATA Select Open File option from the SpecWare File menu 2 Select Logger Location of interest as well as one or more months of data you wish to view and click the Open button 3 Select one or two parameters to plot and click Redraw button 4 To view reports select an option from the Tools menu After selecting a specific report click the View Report tab DEFAULT SETTINGS Preferences Communication Data Storage Graph Monitor l Units Location for ET calculation C Metric Celsius mm km h Latitude degrees 40 OEE SETS el feral earls ieee eon Degree Day Calculations Altitude feet 200 Use Actual Degree Days c Compute Degree Days using the Growing Season Begins in Month Single Sine Method Compute Degree Days using the Growing Degree Day Method Dew Point IV Save as data with Temp and RH January 1 x Date and Time Display Date 1S0 8601 Y M D Device Support z V A Series Loggers Time 12 Hour AM PM an V B Series Button Loggers Report Standard x F C Series Original 2010 03 09 09 31AM 03709 Loggers Stations 1000 2000 Series Loggers Stations Language Preferences General Co ion Data Storage Graph Monitor Direct Connection Gray Cable Port COM1 Communications Port Test Port 2000 A Series Loggers Port Wireless Port COM1 Co
6. ger Station 5 Click the More button to display the properties saved on the station logger 6 Make any changes to the WatchDog Properties and alee the OK button to transfer the settings to the station ogger 2000 Series Station Note When a new station is created in WatchDog Manager that station name is compared to the name on the station itself If they differ you will be given the option to change the name and clear the stations memory See the SpecWare Users manual for details on erasing station data Configuring an Existing Station Logger with SpecWare The process for reconfiguring a station logger that has previ ously been set up in the WatchDog Manager is similar to creating a new station 1 Plug the PC connection cable into your PC and into the station logger Select Watchdog Manager icon from the toolbar menu 2 Select the desired station logger within the WatchDog Manager screen Click the Properties button Click the More button to expand the screen 5 After setting all configuration settings click the OK button to transfer this information to the logger 10 Downloading a Station Logger 1 Plug the PC interface cable into your PC and into the sta tion logger 2 Select WatchDog Manager icon from the toolbar buttons 3 Select the lt Direct Connect 2000 Series gt and click the Readout button 4 Data will be saved to a Logger Location with the same name as the Station Logger Name
7. gger 2 Use the Logger menu item or toolbar icons to get data from the logger Get Data form WatchDog 1000 or 2000 Series Get data from a WatchDog A Series Logger Get Data from an Original WatchDog Data Logger S amp S B or C Series 3 The first time a logger is downloaded or if a new name has been given to it the message An attempt is being made to save data into a nonexistent folder There is no directory folder will be displayed Click on the Yes button to create a new folder Logger Type Direct Connection ltem Black USB to 3 5 mm 1000 Series Station Stereo Plug Cable Included with Specware A Series Logger USB Cable 3661A B Series Button Log ger 9 Pin Serial or USB Dock 3655K 3655K 1 C Series Original Log Black USB to 3 5 mm ger Weather Station Stereo Plug Cable Included with Specware Black USB to 3 5 mm 2000 Series Stations Stereo Plug Cable Included with Specware When using the black cable for the first time the driver will automatically install if the PC is connected to the internet Otherwise use a flash drive to carry the driver from an inter net connected PC Find the link on the Specware 9 update page at www specmeters com To use the cable with Specware Hardware Flow control RTS must be turned off Find this in the Advanced Options page of the commincations tab of Specware Preferences For more information see the 3661U USB to 3 5 mm Stereo Plug Cable product
8. manual WATCHDOG MANAGER 1000 AND 2000 SERIES STATIONS WatchDog Manager easily tracks stations loggers and their data Essential for remote weather stations also can be used for loggers Configuring a 1000 or 2000 Series Micro Mini or Weather Station with WatchDog Manager To change the configuration of the 2000 Series Station or Data Log ger 1 Plug the connection cable into your PC and into the logger and open up SpecWare 2 Select WatchDog Manager bg icon from the toolbar icons l 3 Click the New Station jew siaion 4 Enter the logger name and select the appropriate WatchDog Type and Connection Type and where appropriate Number as noted below Local Direct Connect no number required Wireless Multipoint Enter the Serial of Weather Station Modem Dial out to remote wired Enter the phone number for the station modem Modem Dialout to remote cellular Enter the phone num ber for the station modem e Web SpectrumWeather com Enter Weather Station Model amp Serial as a nine digit ea WatchDog Manager Properties Logger Station Name Enter Logger Station Name VWatchDog Type Connection Type tf 1000 2000 Series Local Direct Connect Original C Series C Wireless Multipoint C Button B Series C Modem Dial out to remote wired A Series Modem Dial out to remote cellular C Web Spectrumeather com Cancel Selecting More will connect to the Log
9. mmunications Port Modem Dial Out Port None Modem Initialization String Original ATZOQOV1X4 MS 22 0 1200 1200 1200 1 2000 Series ATZ0Q0V1X4 Touch Tone Dialing Pulse Rotary Dialing Wait after Connect seconds 0 Advanced Options The default settings are selected in the Preferences screen which is accessed from the File toolbar menu This screen allows you to configure the software s default settings Two important ones should be set immediately e The unit system to be used English or Metric should be set in the General tab The Com Port SpecWare used to communicate with the data logger is selected and can be tested in the Communication tab see Testing the Com Port p 6 Select the Port by clicking on the down arrow highlighting the correct port name it will have a blue background when it is highlighted and click on the OK button at the bottom of the screen 5 TESTING THE COM PORT USB Connection With newer personal computers an RS 232 serial port may not be available If you cannot establish communication with the serial port a USB RS222 serial port adapter Item 3661USB is the best option The adapter requires a driver to be installed on your machine and will work out of a different Com Port than the RS 232 port Identifying the Correct Com Port The computer Communications Port to which the PC interface cable is connected can be identified by using a standard size pa
10. per clip By default a list of the available Com Ports will be listed if not click on the pull down arrow This test is performed with the cable disconnected from the logger 1 Go to the Communications tab of the Preferences screen see p 5 2 Select the com port to be tested and click on the Test Port button If the message Connection OK is displayed another device such as a modem is probably connected to that port If the message No Connection is displayed this port may be the one connected to your serial cable and you can proceed to the next step 3 Place the smallest side of a standard size paperclip about 1 3 8 long on the end of the serial pin so that it touches BOTH the tip of the pin and the metal area between the two black rings Again click on the Test Port button If the message Connection OK now appears this is the com port connected to your serial cable Paper clip or wire ined NOTE The Original dataloggers do not short circuit the serial pin Therefore when the Test Port button is clicked while the logger is connected a Bad Data Returned message will be displayed Testing a Connection to a 1000 or 2000 Series Logger Station In addition to testing the PC interface cable the connection to a 1000 or 2000 Series logger can easily be checked by plugging the cable into the logger s data port and clicking the 2000 button in the Preferences screen refer to the Comm
11. unications tab of the Pref erences screen p 5 6 DATA LOGGERS amp MICRO STATIONS Activating Launching a Data Logger These models will not actively record data until they have been started via SpecWare software Launching a logger will clear all data from its memory Care should be taken that the logger has been downloaded before initiating the launch sequence The launch proce dure is as follows 1 Plug the PC connection cable see chart on pg 8 into your PC and into the logger 2 Use the Logger menu item or toolbar icons to launch the logger Launch Set Properties for WatchDog 1000 or 2000 Launch a WatchDog A Series S amp S Launch Original WatchDog B or C Series 3 Enter the appropriate information in the WatchDog Properties screen 4 Click the OK button to transfer the settings to the logger and begin the data logging process Note 1000 Series Micro Stations do not need to be re launched if the Wrap around when full has been checked in the WatchDog Proper ties They will retain old data until the space is needed for new data 4 The first time a logger is downloaded or if a new name has been given to it the message An attempt is being made to save data into a nonexistent folder There is no directory folder will be displayed Click on the Yes button to create a new folder Downloading a Data Logger 1 Plug the PC connection cable see chart pg 8 into your PC and into the lo