User Manual Swiss Garde 320 HF UP

image

Contents

1. LUX twilight sensor The twilight sensor regulates the operating threshold light value of the detector determining when the device should be activated Minimum value 10 lux moon symbol The detector will turn on the light at night Maximum value 1000 lux sun symbol The detector will turn on the light during daytime as well Detection range top view frontal detection SENSITIVE max 15m Detektion frontal Troubleshooting error cause amendment light does not turn on twilight adjustment value too low connected lamp defective check mains power fuses detector triggers without reason check detection area for potential reason light never turns off causes of false triggering draught heating etc may all provoke faulty switching detector is too sensitive reduce the detec tion range sensitivity by re mote control or manually or cover disturbing segments on the lens by adhesive tape check distances to lamps heat re flection or direct light influence connect RC element in parallel to transformers relais electric ballast light flashes periodically non compensated fluorescent lamps detector doesn t reach need an RC element or compensa proper working condition tion condenser installed triggers or blocks at mains install a Varistor between phase L voltage peaks and neutral N wires light turns off even if motion increase the TIME value to maxi is detected mum if ne
2. User Manual 160 Wall Mounted HF Detector Swiss Garde 320 HF UP Warning Any work on the main power supply must only be completed by trai ned specialists The product must be installed in accordance with installation guideli nes standards specific to your country Disconnect the 230V power supply before starting the installation process As a precautionary measure the power supply of the light should always be fitted with a 250VAC 10A type C fuse in accordance with EN60898 1 Faulty lamps may cause short circuit and damage the device Disconnect power prior to replacing a lamp To ensure the operational reliability of the detector keep a minimal distance of 1m to lamps installed on the same height level Lamps installed underneath the detector or in the detection area may disturb the functionality Keep detector away from heating devices In case of malfunction such as continuous lighting or false triggering please refer to the troubleshooting section on page 9 Function The high frequency motion detector actively emits high frequency elec tro magnetic waves 5 8 GHz and reacts to changes made by objects reflecting the waves back If the detector identifies a change the light is switched on and switches off again once the preset time has elapsed approx 8 seconds to 12 minutes Changes can also be detected through thin walls doors and glass Detection area As the device is activated by reflection
3. eded turns the light on during twilight adjustment set too high set daytime to a lower value Respect 1 min start up detector is installed in the shade consider changing the location of detector After mains connection the detector takes approx 1 min to reach a stable working condition Technical data Nominal power 230V 50Hz Frequency 5 8 GHz 1 mW Switching power 2300W 10A max cos 1 1150VA 5A max inductive cos 0 5 Time adjustment approx 8 sec to 12 min Twilight switch 10 to 1000 lux Detection area 160 horizontal Range approx 1 5 to 15 frontal 4 m lateral Installation height 1 1 to 1 5m Dimensions 80 x 80 x 20 mm Temperature range 10 to 55 C IP protection IP 20 class Il Electronic Control Induction in long installation wires if several detectors connected in parallel may generate a considerable capacitive current on the switched phase For electric loads using only a small control current such as staircase timer switches this may lead to permanent switching or general malfunctions In order to minimise the capacitive current an RC element may be connected in parallel to the load Alternatively a contactor which is more tolerant to Capacitive currents may be installed before the load We recommend a maximum of four detectors connected in parallel Do not dispose of electrical appliances in your waste bin use the collecting point of your municipality o
4. r return the old device to your dealer MN DX cf
5. s the range varies depending on the installation location i e range reduced in an empty factory buil ding Transmitting power electric smog The transmitting power of the sensor is 1mW while that of a GSM mo bile phone or microwave is 1000 to 2000 times higher Installation site Install the device at a height of approx 1 1 to 1 5 m above ground Wire the detector as follows phase outer conductor L brown neutral neutral conductor N blue switching output switched phase outer conductor L red Optional remote switching R via supply of the phase impulse switch no neon bulbs Device may not be remote switched through phase interruption Device operational 1 minute after main connection 2 Device may be operational with out frame for testing purposes easier to remove detector head Note Remove voltage before re moving detector head Connecting electrical loads High inrush currents will considerably shorten the lifetime of the detec tor s in built relay Please verify the technical data provided by the lamp or luminaires manufacturer concerning inrush currents specifically with compact fluorescent fluorescent lamps electronic ballast etc in order not to overload the internal relay We recommend connecting a maximum of three to four motion detec tors in parallel If the number of switching cycles is above average or in the event of increased inductive loads we recommend using the short p
6. ulse function on the motion detector and switching the load via an external staircase timer switch or contactor Keep cables lengths to a minimum in order to prevent capacitive standby current Wiring diagrams Standard installation optional push button connected to clamp R for remote detector lights switching keep wire short Bewegungs melder D tecteur de snnnnnnnennne mouvement Bewegungs melder Bewegungs melder Bewegungs melder D tecteur de mouvements D tecteur de mouvements D tecteur de mouvements Installation of an RC element between neutral conductor N and switched phase L in case of interferences by fluorescent lamps switch off sparks or by several detectors connected in parallel cau sed by capacitive current in the wires Varistor between neutral conductor N und phase L to reduce mains voltage peaks Bewegungs melder D tecteur de s mouvements Controls Caution Always remove voltage before removing detector head SENS sensitivity detection range Detection range adjustment max approx 15 m frontal 4 m lateral Should the detector be too sensitive triggering without movement in the detection range the sensitivity range can be reduced TIME The timer determines for how long the lights will remain on following the last movement in the detection area Min approx 8 seconds up to max 12 minutes

Download Pdf Manuals

image

Related Search

Related Contents

CD-R/RW&DVD-ROM ドライブ 取扱説明書  2014-08-12-2-GWU-Fac.. - University of Colorado Boulder  Aplusix 3.1 User Manual  ESTACION SOLAR  L`article au format PDF  VizAlert Laser Jammer Interface - Blinder M25  cegard/Mini-MOD  Kingston Brass HKUS292010DBNL Installation Guide  OMT-20X manual - e  Samsung 7100 Medical Alarms User Manual  

Copyright © All rights reserved.
Failed to retrieve file