DWLMA XMI PIU Installation Guide
Contents
1. EDO HEN ER ie A i Plunger Plunger fastener Hinges fastener BXB 0446 92 A 2 Moving Hingeson the Bulkhead Door Figure A 1 shows two bulkhead doors one hinged left and the other hinged right Follow these steps when moving the hinges on the doors from one side to the other The steps assume the door is hinged left 1 Remove the door by unscrewing the shoulder bolt hinges at the top and bottom Note that the nylon washers are between the enclosure and the door 2 Movethe plastic spacer on the bottom right flange of the enclosure to the bottom left of the enclosure where the bottom hinge used to be 3 Remove the EMI finger stock from the top flange on the enclosure 4 Using two 3 8 inch wrenches remove the plunger fastener on the top flange of the enclosure and reinstall it one hole to the left of its origi nal location Put the plunger in its hold open position to secure the top wrench and hold the nut under the flange with the other wrench and remove or tighten 5 Reinstall the EMI finger stock Remove the EMI finger stock from the bottom of the door 7 Using two 3 8 inch wrenches remove the plunger fastener on the bot tom of the door and reinstall it one hole to the left of its original loca tion Put the plunger in its hold open position to secure the top wrench and hold the nut under the flange with the other wrench and remove or
2. BXB 0444 93 2 6 Installation of the XMI PIU The 4 to 1 cable is labeled for easy correct installation The bulkhead end of the cable is easily identified by the bulkhead plate and the receptacle for thelOP cable The XMI backplane end has four connectors labeled DL DR EL andER To install the cable 1 2 von ou Remove the plastic shield from the XMI backplane Figure 2 4 shows the I O bulkhead door If the XMI PIU is installed on the left the bulkhead plate of the 4 to 1 cable goes in A5 if it is on the right the bulkhead plate goes in Al Select and remove the cor rect panel from the I O bulkhead door The lOP connector is offset on the bulkhead plate When the plate is installed in a system cabinet the connector is to the left of center When the plate is installed in an expander cabinet the connector is right of center Install the bulkhead end of the 4 to 1 cable in the bulkhead door by passing the cables through the door and secure by using the two screws removed from the plate in step 2 The DWLMA adapter goes in slot 8 Slot 7 is used for the clock mod ule and has no connectors Slot 8is toits right on the XMI backplane See Figure 2 3 Install the cable marked DL into the left receptacle of row D slot 8 Install the cable marked DR into the right receptacle of row D slot 8 Install the cable marked EL into the left receptacle of row E slot 8 Install the cable marked ER into the right re
3. in either slot 1 or 14 to terminate the XMI bus Restore power to the system and check the self test results to see that the XMI PIU is functioning properly Example 3 1 Sample Self Test Display F E D C B A 9 8 7 6 5 4 3 2 1 0 NODE ff A M P P TYP o STI E B BPD o ST2 E B BPD ST3 A A E i 5 E B BPD o a s Hoa a 3 ei RO xy A CO XMI Q 3 i C1 XMI 2 C2 c3 AO g 5 a 5 ILV 128 128MB Firmware Rev v1 0 1625 SROM Rev v1 0 0 SYS SN GA01234567 P00 gt gt gt BXB 0030Q 93 3 2 Verification To verify that the XMI PIU is functioning properly 1 Insert a supported XMI option into either slot 1 or 14 to terminate the XMI bus The module you install must have an XMI corner on it Power on the system and examine the self test results to determine whether the XMI PIU passes Example 3 1 shows sample self test re sults Two XMIs are shown in the example The at the end of the line marked shows that the XMI connected to the CO hose is functioning The at the end of the line marked shows that the XMI connected to the C1 hose is not functioning Lines CO C1 C2 and C3 correspond to IOP ports see Figure 3 1 In Example 3 1 the XMI connected to IOP port Cl is failing If the C line indicates a problem check all the cabling and retest If the prob lem continues follow the troubleshooting procedures in your system s Advanced Troubleshooting m
4. tighten 8 Reinstall the EMI finger stock on the door 9 Press the door into the enclosure allowing the EMI finger stock to hold it in place 10 Reinstall the shoulder bolt hinges on the right Be sure to place the nylon washers between the enclosure and the door Moving Hingeson the Bulkhead Door A 3 A Airflow plate removal 2 2 C Configuration rules 1 3 Installing card cage assembly 2 4 DWMLA module 2 10 IOP cable 2 8 rear cable enclosure 2 4 4to 1 cable 2 6 I O port diagram 3 4 S Self test results 3 2 X XMI configuration rules 1 3 XMI PIU kit contents 1 4 placement 1 2 XMI termination requirement 1 3 Index Index 1
5. 4 to 1 cable you just installed and secure the end of the cable 4 Once the cable has been installed replace the skirt at the back of the cabinet Installation of the XMIPIU 2 9 2 5 Installing the DMLMA The DWLMA is installed in slot 8 of the XMI card cage The XMI PIU comes with the clock card already installed in slot 7 Slot 8 is to the left of slot 7 when looking into the card cage Figure 2 6 Front DWLMA Module Installing the DWLMA XMI Card Cage 14 13 1211109 87654 321 A module is required in slot 1 or 14 to terminate bus BXB 0438 93 2 10 Installation of the XMI PIU Clock Module To install the DWLMA 1 Atthefront of the cabinet ground yourself using the ESD strap 2 Install the DWLMA the T2028 AA module in slot 8 Slot 8 is the slot to the left of the clock module already installed Before installing and cabling all sorts of I O options you might want to verify the PIU installation by proceeding to the Verification chapter Installation of the XMI PIU 2 11 Chapter3 Venr fic ation This chapter describes the acceptance procedure and troubleshooting guidelines for the XMI PIU Seethe Advanced Troubleshooting manual for more information Sections include e Restore Power and Check Self Test Results Verfication 3 1 3 1 Restore Power and Check Self Test Results Install a supported XMI option with an XMI corner
6. DWLMA XMi PIU Installation Guide Order Number EK DWLMA IN 001 This manual describes the installation of the XMI PIU into VAX 7000 10000 and DEC 7000 10000 AXP systems Both system and ex pander cabinet installation are covered digital equipment corporation maynard massachusetis First Printing February 1993 The information in this document is subject to change without notice and should not be construed as a commitment by Digital Equipment Corporation Digital Equipment Corporation assumes no responsibility for any errors that may appear in this document The software if any described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license No re sponsibility is assumed for the use or reliability of software or equipment that is not supplied by Digital Equipment Corporation or its affiliated companies Copyright 1993 by Digital Equipment Corporation All Rights Reserved Printed in U S A The following are trademarks of Digital Equipment Corporation Alpha AXP DECUS VAXBI AXP DWMVA VAXELN DEC OpenVMS VMScluster DECchip ULTRIX XMI DEC LAN controller UNIBUS The AXP logo DE Cnet VAX ill i tal OSF 1 is a registered trademark of the Open Software Foundation Inc FCC NOTICE The equipment described in this manual generates uses and may emit radio frequency energy The equipment has been type tested and found to comply with the limits f
7. EK 7000A SV System Service M anual EK 7002B SV Pocket Service Guide EK 7000A PG Advanced Troubleshooting EK 7001A TS Service Information Kit DEC 7000 EK 7002B DK Platform Service Manual EK 7000A SV System Service M anual EK 7002B SV Pocket Service Guide EK 7700A PG Advanced Troubleshooting EK 7701A TS vii Table 1 DEC 7000 VAX 7000 Documentation Continued Title Order Number Reference Manuals Console Reference M anual EK 70COB TM KA7AA CPU Technical Manual KN7AA CPU Technical Manual MS7AA Memory Technical Manual 1 O System Technical Manual Platform Technical Manual Upgrade Manuals KA7AA CPU Installation Card KN7AA CPU Installation Guide MS7AA Memory Installation Card KZMSA Adapter Installation Guide DWLMA XMI PIU Installation Guide DWMBB VAXBI PIU Installation Guide H 7237 Battery PIU Installation Guide H 7263 Power Regulator Installation Card BA654 DSSI Disk PIU Installation Guide BA655 SCSI Disk and TapePIU Installation Guide Removable Media Installation Guide EK KA7AA TM EK KN7AA TM EK MS7AA TM EK 70IOA TM EK 7000A TM EK KATAA IN EK KN7AA IN EK MS7AA IN EK KXMSX IN EK DWLMA IN EK DWMBB IN EK H7237 1N EK H7263 1N EK BA654 IN EK BA655 IN EK TFRRD IN viii Table 2 Related Documents Tide Order Number General Site Preparation Site Environmental Preparation Guide System I O Options BA350 Modular Storage Shelf Subsystem Configuration Guide BA350 Modular Sto
8. abinets If you are installing the PIU in an expander cabinet drop the skirts below the rear doors of both cabinets Remove the two airflow plates from the front and rear of the cabinet see Figure 2 1 These slide out of the cabinet and should be labeled and saved If the PIU is removed these plates must be replaced to maintain proper airflow in the cabinet The bulkhead door on the rear cable enclosure of the XMI PIU comes hinged on the left If the XMI PIU is placed in the cabinet on the left when viewed from the rear quadrants 3 and 4 the door should be hinged on the right If you need to change the hinges do that now following the procedure in Appendix A Installation of the XMIPIU 2 3 2 2 Installing the Card Cage Assembly The BA651 AA card cage assembly consists of two parts the card cage assembly with the clock module and power regulators and the rear cable enclosure First install the card cage assembly and then the rear enclosure Figure 2 2 Installing the XMI PIU Rear BXB 0405D 93 2 4 Installation of the XMI PIU Toinstall the XMI PIU NOTE Beforeinstalling the PIU inspect the e etromagnetic interference EMI gaskets return the option if they are damaged 1 Ground yourself to the cabinet with the antistatic wrist strap from the Electrical Safety Kit 2 Plac
9. anual To verify that each slot in the backplane works do the following 1 2 3 4 Install a known good module in the slot you wish to test Power on the system Examine the self test results to determine whether the slot is working Repeat steps 1 through 3 for each slot If a slot fails return the option If the XMI PIU passes verification con tinue with the installation of XMI options Figure 3 1 IOP Port Diagram CO C1 C2 C3 BXB 0623 93 Venfication 3 3 Appendix A Moving Hinges on the Bulkhead Door TheXMI plug in unit comes with the rear bulkhead door hinged at the left The door opens properly when the enclosure is in the rear right quadrant Q2 When the enclosure is in the rear left quadrant Q4 the door should be hinged on the right so that the hose is moved as little as possible when the door is opened This appendix describes how to change the hinges Moving Hinges on the Bulkhead Door A 1 A 1 Moving the Hinges ofthe Bulkhead Door In addition to moving the hinges from one side of the bulkhead door to the other the EMI finger stock and the plunger fasteners must be moved Figure A 1 Bulkhead Doors on the XMI PIU Rear Cable Enclosure Plunger Plunger fastener fastener i a 4 i
10. ation of the XMI PIU describes the installation procedure e Chapter 3 Verification describes the acceptance procedures e Appendix A Moving Hinges on the Bulkhead Door describes how to move the hinges on the I O bulkhead door Conventions Used in This Doc ument Terminology Unless specified otherwise the use of system refers to either a DEC 7000 AXP or VAX 7000 system The DEC 7000 AXP systems use the Alpha AXP architecture References in text use DEC 7000 to refer to DEC 7000 AXP systems Book titles In text if a book is cited without a product name that book is part of the hardware documentation It is listed in Table 1 along with its order number Icons Theicons shown below are used in illustrations for designating part placement in the system described A shaded area in the icon shows the location of the component or part being discussed Front Rear Documentation Titles Table 1 lists the books in the DEC 7000 and VAX 7000 documentation set Table 2 lists other documents that you may find useful vi Table 1 DEC 7000 VAX 7000 Documentation Title Order Number Installation Kit EK 7000B DK SitePreparation Guide EK 7000B SP Installation Guide EK 700EB IN Hardware User Information Kit EK 7001B DK Operations Manual EK 7000B OP Basic Troubleshooting EK 7000B TS Service Information Kit VAX 7000 EK 7002A DK Platform Service Manual
11. ceptacle of row E slot 8 Replace the plastic shield Figure 2 4 I O Bulkhead Panel Designations 12 34 5 12 34 5 BXB 0443 93 Installation of the XMIPIU 2 7 2 4 Installing the IOP Hose Cable The IOP hose cable part number 17 03085 01 or 17 03085 02 con nects the IOP in the system cabinet and the I O bulkhead The longer hose the 01 variation is used when the PIU is installed in an expander cabinet Figure 2 5 shows the IOP cable routing for both system and expander cabinets Figure 2 5 IOP Cable Installation and Routing Rear System Rear Expander IOP Module Expander System Cabinet l OCable Cabinet I O Cable BXB 0437 93 2 8 Installation of the XMI PIU ThelOP cable is labeled for easy and correct installation ThelOP end is labeled IOP and the bulkhead end is labeled PIU To install the cable 1 Plug thelOP end of the cable into one of the IOP module connectors and secure the end of the cable 2 Routethe cable according to Figure 2 5 shows the routing for the cable in a system cabinet and shows the routing for a cable to an expander cabinet 3 PlugthePIU end of the cable into the bulkhead connector end of the
12. ethe XMI card cage half into the cabinet by lining up the rollers on the PIU with the slides in the cabinet Now push the card cage into the cabinet until t seats 3 Lineup and only slightly tighten the two captive screws slotted at the top of the PIU amp in Figure 2 2 4 Install the two Phillips head screws at the bottom of the card cage se curing the PIU tothe cabinet in Figure 2 2 Tighten the two cap tive screws mentioned in step 3 to 27 inch pounds 5 Besurethel O bulkhead door opens in the correct direction before proceeding to step 6 See Section 2 1 step 8 6 At the back of the cabinet install the rear cable enclosure lining up the rollers on the PIU with the slides in the cabinet 7 Lineup and only slightly tighten the two captive screws slotted at the top of the enclosure 8 Install the two Phillips head screws at the bottom of the cable endo sure securing the back of the PIU tothe cabinet Tighten the two cap tive screws mentioned in step 7 to 27 inch pounds Tightening these screws compresses the EMI gaskets between the two halves Installation of the XMIPIU 2 5 2 3 Installing the 4 to 1 Cable The 4 to 1 cable part number 17 03061 01 is installed between the XMI backplane and the I O bulkhead Figure 2 3 Placementofthe 4 to 1 Cable Rear Slot 1 2 3 4 5 6 7 8 9 10 11 12 13 14 DL Di DA DR N EL Et E2 ER
13. hose cable for the expander cabi net DWLMA BA variant EK DWLMA IN 1 This installation guide OnelOP hose cable is present The 4 5 foot cable is in the system cabinet kit and the 10 foot cable is in the expander cabinet kit Introduction 1 5 Chapter2 Installation ofthe XMi PIU Five tasks are necessary to install an XMI PIU They are Preparing the Cabinet Installing the Card Cage Assembly Installing the 4 to 1 Cable InstallingthelOP Hose Cable Installing the DWLMA Installation of the XMI PIU 2 1 2 1 Preparing the Cabinet After you determine the XMI PIU quadrant location you must re move the airflow plates located below the blower and above the quadrants you will be using Figure 2 1 Airflow Plate i Front BXB 0412B 93 2 2 Installation of the XMI PIU Take the following steps to prepare the system 1 2 3 Perform an orderly shutdown of the system Turn the keyswitch to Disable Determine which quadrants will housethe XMI PIU in the system or expander cabinet See Section 1 1 for placement rules Open the front and rear doors of the cabinet If you are installing the XMI PIU in an expander cabinet you will need access to the rear of the system cabinet also Shut the circuit breaker on the AC power box off by pushing down on the breaker The AC power box is above the blower and to the left in both c
14. nnsnnnnnnnnnnnnnnnnnnnnnnnnn 1 4 Airflow Plate ie 2 2 Installing the XMI PIU n eeenseesssesnnnnnnennnnnnnnnnnnnnnnnnnnnnn nn 2 4 Placement of the 4 to 1 Cable sees renerne 2 6 I O Bulkhead Panel Designations nuunmersnennsennnnnnnnennn nn 2 7 IOP Cable Installation and Routing eses 2 8 Installing the DWLMA neunsennnsnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnn 2 10 LOP Port Diagram civic a 3 3 Bulkhead Doors on the XMI PIU Rear Cable Enclosure A 2 DEC 7000 VAX 7000 Documentation cooooconccccconcncononcncannnoos vii Related Documents ueeeeeensnnnensennennnnennnennnnnnnnnenennonnnnn nenn ann ix DWLMA XMI PIU Kit Contents eeessenenenneeenennennnnenene nn 1 5 Preface Intended Audience This manual is written for Digital service engineers installing XMI plug in units in systems with an LSB as the system bus Doc ument Structure This manual uses a structured documentation design Topics are organ ized into small sections for efficient on line and printed reference Each topic begins with an abstract You can quickly gain a comprehensive over view by reading only the abstracts Next is an illustration or example which also provides quick reference Last in the structure are descriptive text and syntax definitions This manual has three chapters and one appendix as follows e Chapter 1 Introduction describes the XMI PIU its placement in the system and XMI configuration rules e Chapter 2 Install
15. o kits is the length of the cable that goes from the IOP in the system cabinet to the I O bulkhead Figure 1 2 shows the XMI PIU assembly Figure 1 2 XMI Card Cage Assembly XMI Card Cage Rear Cable Enclosure Clock Module T2030 YA QQ OOOOOOOO00O BXB 0368C 93 1 4 Introduction The contents of the two kits follows e ThexXMI PIU card cage assembly consists of two major pieces The card cage itself with the power regulators which plugs into either cabinet from the front The dock module is already installed in the card cage Therear cable enclosure consisting of the enclosure and the bulk head pane door that plugs into either cabinet from the back Fig ure 1 2 shows the two pieces See Section 2 2 for installation e TheDWLMA adapter module is placed in slot 8 of the XMI See Sec tion 2 5 for installation e The4tolcableis placed between the 1 O bulkhead and the XM I backplane See Section 2 3 for installation e Either the 4 5 foot or 10 foot cable connects the IOP module and the I O bulkhead See Section 2 4 for installation Table 1 1 DWLMA XMI PIU Kit Contents Part Number Quantity Description BA651 AA 1 XMI PIU card cage assembly clock mod ule T2030 YA and the DC to DC power regulators T2028 AA 1 DWLMA module 17 03061 01 1 4 to 1 cable with bulkhead 17 03085 02 iS 4 5 foot hose cable for the system cabinet DWLMA AA variant 17 03085 01 F 10 foot
16. or a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such radio frequency interference when operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case the user at his own expense may be required to take measures to correct the interference A Ne eh ee v Chapter 1 Introduction 1 1 XMI PIU Placement and Rules seesesssssssirrrrrrrrrrrirrrrnn 1 2 1 2 XMI PIU Kit Contents aiiis panien aa ivast aana 1 4 Chapter 2 Installation of the XMI PIU 2 1 Preparing the Cabinet inmcccccinccnnnccnoccnncccnncnnnncnanennnrannnnnnnnno 2 2 2 2 Installing the Card Cage Assembly nunnsenssenssennsnnnnnnnen nn 2 4 2 3 Installing the 4 to 1 Cable umnnnnnennnsnnnnnnnnnnnnnnnnnnn nn 2 6 2 4 Installing the IOP Hose Cable uunnnennnsensnennsnnnnnnnnnnnn nn 2 8 2 5 Installing the DWLMA unennsennnsensnennnnnnnnnnnnnnnnnnnn nennen 2 10 Chapter 3 Verfication 3 1 Restore Power and Check Self Test Results 3 2 Appendix A Moving Hinges on the Bulkhead Door Al Moving the Hinges of the Bulkhead Door A 2 Examples 3 1 Sample Self Test Display 2 secs serene nen rr 3 2 Figures 1 1 1 2 2 1 2 2 2 3 2 4 2 5 2 6 3 1 A 1 Tables 1 2 1 1 System and Expander Cabinet XMI PIU Placement 1 2 XMI Card Cage Assembly ueesnennsensne
17. ork Management Utilities AA PQYAA TK Guideto Installing DEC OSF 1 AA PS2DA TE OpenVMS Alpha Version 1 0 Upgrade and AA PQYSA TE AA PRAHA TE AA LA50A TE EK HSCMN IN EK SC008 UG AA PBTVA TE EK VT420 UG EK LA75X UG Chapter 1 Introduction The XMI plug in unit PIU is an I O subsystem bus that can be installed in an LSB system cabinet or an LSB expander cabinet This chapter de scribes the placement of the XMI PIU in both the system and expander cabinets and the contents of the two kits It also lists XMI configuration rules Sections include e XMI PIU Placement and Rules e XMI PIU Kit Contents Introduction 1 1 1 1 XMI PIU Placementand Rules The XMI PIU takes up two of four quadrants of space in the bot tom of either a system or expander cabinet The XMI card cage is installed in either the right or left front quadrant and extends into the rear quadrant Figure 1 1 System and Expander Cabinet XMI PIU Placement Rear System Quadrant 2 Quadrant 4 Quadrant 1 Quadrant 3 1 2 Introduction Rear Expander Front Expander BXB 0044M 93 Figure 1 1 shows the quadrant designation for system and expander cabi nets XMI PIUs are installed in the bottom of either cabinet with the card cages and power regulators installed in the front The XMI PIU
18. rage Shelf Subsystem User s Guide BA350 LA Modular Storage Shaf User s Guide CIXCD Interface User Guide DEC FDDIcontroller 400 I nstallation Problem Solving DEC LANcontroller 400 Installation Guide DEC LAN controller 400 Technical Manual DSSI VAXcluster Installation and Troubleshooting Manual InfoServer 150 Installation and Owner s Guide KDM70 Controller User Guide KFMSA Modulelnstallation and User Manual KFMSA Module Service Guide RRD42 Disc DriveOwner s Manual RF Series Integrated Storage Element User Guide Tx85 Series Cartridge Tape Subsystem Owner s Manual TLZO6 Cassette Tape Drive Owner s Manual EK CSEPG MA EK BA350 CG EK BA350 UG EK 350LA UG EK CIXCD UG EK DEMFA IP EK DEMNA IN EK DEMNA TM EK 410AA MG EK INFSV OM EK KDM 70 UG EK KFMSA IM EK KFMSA SV EK RRD42 OM EK RF72D UG EK OTF85 OM EK TLZ06 OM Table 2 Related Documents Continued Installation Manual VMS Upgrade and Installation Supplement VAX 7000 600 and VAX 10000 600 Series VMS Network Control Program Manual VMSclusters and Networking HSC Installation Manual SC008 Star Coupler User s Guide VAX Volume Shadowing Manual Peripherals Installing and Using the VT 420 Video Terminal LA75 Companion Printer Installation and User Guide Tite Order Number Operating System Manuals Alpha Architecture Reference M anual EY L520E DP DEC OSF 1 Guideto Systen Administration AA P U7A TE DECne for OpenVMS Netw
19. requires two quadrants of space quadrants 1 and 2 if the card cage is installed on the left and quadrants 3 and 4 if it is installed on the right when you face either cabinet From the front of either cabinet the XMI PIU must beto the left of a VAXBI PIU if one is installed The following rules apply XMI PIUs in cabinets 1 a b E XMI PIUs are placed in the bottom of cabinets A maximum of two XMI PIUs can be placed in a cabinet A maximum of four XMI PIUs can be placed in a system XMI PIU Configuration Rules a Each XMI PIU occupies two of the bottom quadrants Land 2 or 3 and 4 The XMI PIU occupies quadrants 1 and 2 when a VAXBI PIU is installed The XMI bulkhead has 20 dual I O panels One is used for the I O cable from the IOP XMI Configuration Rules a b Of the 14 slots on the XMI 12 are available for O devices Two slots are reserved slot 7 for the T2030 Y A the clock module and slot 8 for the T2028 AA the DWLMA module The first option on an XMI must reside either in slot 1 or slot 14 to terminate the bus If the option is a two module option the mod ule with the XMI corner must bein slot 1 or 14 If the cabinet has a VAXBI PIU the T2018 module XBI A must reside in slot 1 of the XMI backplane Introduction 1 3 1 2 XMI PIU Kit Contents The DWLMA XMI PIU option has two variants one for a system cabinet and the other for an expander cabinet The only differ ence between the tw
Download Pdf Manuals
Related Search
Related Contents
USER`S MANUAL - Icon Heath & Fitness 省電力機能を強化し、コストパフォーマンスに優れた22型ワイド <<< manuale d`uso e installazione Les cas en allemand : un problème enfin résolu Diamond View DV158 User Manual Omni8/16C/Omni8P User Manual Sony CDX-GT620U Operating Instructions Dieses Archiv können Sie hier herunterladen. Copyright © All rights reserved.