Home

USB-Serial Conversion Cable User`s manual

image

Contents

1. USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin XW2Z 200P V D sub 25 pin Not necessary RS 232C Host link female 500P V male D sub SYSWAY Length 2 or 5 m 25 pin female e C series Communications Board C200HX HG HE PLCs Only USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin KW2Z 200S CV D sub 9 pin Not necessary IRS 232C Host link female 500S CV male D sub SYSWAY Length 2 or 5 m O pin D sub 9 pin XW2Z 200S V D sub 9 pin Not necessary female female 500S V male Length 2 or 5 m e C200H C1000H and C2000H Host Link Units Note The C500 LK203 and C500 LK 201 V1 Host Link Units can be used with the C1000H and C2000H The C200H LK201 V1 and C120 LK201 V1 Host Link Units can be used with the C200H USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin XW2Z 200P V D sub 25 pin Not necessary IRS 232C Host link female 500P V male D sub SYSWAY Length 2 or 5 m 25 pin female e CQM1H Serial Communication Board USB Cable 1 Cable 2 Unit s port Serial Conversion communicatio
2. D sub 25 pin female to eS 9 pin female Adapter el CVM1 CV series PLC connection D sub Connector 25 pin male V series peripheral connector Peripheral port Recommended cable CV500 CIFO1 e Connecting to the RS 232C Port Using a XW2Z 200S V 500S V Cable D sub Connector F 9 pin male CVM1 CV series PLC connection D sub Connector 9 pin male D sub Connector 9 pin female RS 232C port D sub Connector 9 pin female Recommended cable XW2Z 200S V 500S V 20 PTs NS and NT Series e Connecting to the RS 232C Port Using a XW2Z S002 Cable LJ USB type A plug male CS1W CIF31 D sub Connector U 9 pin male D sub Connector D sub Connector 9 pin male 9 pin female YY XW2Z S002 Programmable Relay ZEN USB type A plug male CS1W CIF31 D sub Connector Personal Computer CN D sub Connector 9 pin female Personal Computer Connecting Cable ZEN CIF01 System Configuration PT connection RS 232C port Personal Computer Connecting port 21 USB to PLC PT Connection Tables USB to PLC PT Connection Tables Connecting with the CS1W CIF31 D sub Connector Cable Cable 2 when necessary Computer CSTW CIFS1 Cable 1 CS1W N226 626 Programming Device Connecting Cable for a CS CJ series peripheral port CS1W CN114 D g C series peripheral port to CS CJ s
3. The USB Serial Conversion Cable uses one of the computer s COM ports to communicate The communications port COM port allocated to the Conversion Cable must be selected with the CX Programmer in order to connect online to a PLC or PT Note It may take some time for the computer to detect the cable after the cable is connected This is not a malfunction ll Selecting the Cable s COM Port in CX Programmer Use the following procedure to select the COM port used by the Conversion Cable 1 Display the Change PLC dialog box Change PLC Device Name Device Type CM Y Settings Network Type Toolbus y Settings Comment Ceat 2 Click the Settings button in the Network Type area Select the desired type of network The Network Settings dialog box will be displayed 3 Click the Driver tab in the Network Settings dialog box Network Settings Toolbus Network Driver Modem Connection PotName Eu Baud Rate 19200 v I Baud Rate Auto Detect Make Default Cancel Help 36 Connecting Online from the CX Programmer 4 Locate the Port Name setting and selectthe COM port being used by the Conversion Cable Network Settings Toolbus Network Driver Modem r Connection PortName COM3 y COM1 Baud Rate I Baud Rate Auto Detect Make Default Cancel Help Note If you fail to connect with this USB Cable turn OFF auto baud rate
4. C series peripheral connector CS CJ series peripheral connector a ad Recommended cable POM SIEGE CS1W CN114 D sub Connector 9 pin female Peripheral port Note With a CS CJ series PLC the connection must be a host link connection 18 System Configuration Using a XW2Z 200S CV 500S CV or XW2Z 200S V 500S V Cable for an RS 232C Connection USB type A plug male CS1W CIF31 D sub Connector pi l ut 9 pin male CQM1H PLC connection CPM2C PLC connection D sub Connector D sub Connector 9 pin male 9 pin female Peripheral port XW2Z 200S CV 500S CV or xw2z 2008 v soos v D sub Connector See note 9 pin female CS1W CN118 Note With a CS CJ series PLC the connection must be a host link connection CS CJ series peripheral connector Connecting to the RS 232C Port Using a XW2Z 200S CV 500S CV or XW2Z 200S V 500S V Cable for an RS 232C Connection USB type A plug male CS1W CIF31 D sub Connector 9 pin male D sub Connector CQM1H PLC connection CPM2C PLC connection D sub Connector 9 pin female RS 232C port D sub Connector 9 pin female XW2Z 200S CV 500S CV or XW2Z 200S V 500S V See note Note With a CS CJ series PLC the connection must be a host link connection 19 System Configuration CVM1 and CV series PLCs e Connecting to the Peripheral Port e Using a CV500 CIF01 Cable USB type A plug male CS1W CIF31 D sub Connector 9 pin male
5. Communication Unit Board connection or PTs ZEN CIFO1 Personal ZEN Personal Computer Connecting Cable Computer Connecting port MOTO The USB Serial Conversion Cables are for connections between a USB port and an OMRON PLC PT only In particular the CS1W CIF31 Cable can be used only with compatible OMRON software applications even though it has a standard D sub 9 pin connector on one end General Specifications Specifications USB Interface rating Conforms to USB Specification 1 1 DTE speed 115 2 kbps Connector specifications Computer end USB type A plug male PLC end RS 232C D sub 9 pin male Power supply Bus power 5 VDC power from upstream Current consumption 35 mA Operating environment Ambient temperature 0 to 55 C Ambient humidity 10 to 90 humidity with no condensation Atmosphere No corrosive gases Weight 50g 13 14 Dimensions D sub Connector Cable CS1W CIF31 72 4 500 46 11 75 6 e E p E H N o 8 4 5 System Configuration System Configuration CS CJ series PLCs e Connecting to the Peripheral Port Using a CS1W CN226 626 Cable D sub Connector 9 pin male CS CJ series PLC connection Customizable Counte
6. V 500S V See note Note With a CS CJ series PLC the connection must be a host link connection 16 System Configuration C series PLCs lg C200HS C200HX HG HE C200H C1000H C2000H CQM1 CPM1 CPM1A CPM2A or SRM1 Connecting to the Peripheral Port Using a CQM1 CIF02 Cable USB type A plug male CS1W CIF31 D sub Connector y em male D sub Connector 9 pin female C series PLC connection C series peripheral connector Recommended cable CQM1 CIFO2 Connecting to the RS 232C Port Using a XW2Z 200S CV 500S CV or XW2Z 200S V 500S V Cable for an RS 232C Connection USB type A plug male CS1W CIF31 D sub Connector C series PLC connection 9 pin male D sub Connector 9 pin male D sub Connector 9 pin female RS 232C port D sub Connector 9 pin female Recommended cable XW2Z 200S CV 500S CV or XW2Z 200S V 500S V 17 System Configuration ll CQM1H and CPM2C PLCs Connecting to the Peripheral Port Using a CS1W CN226 626 Cable USB type A plug male CS1W CIF31 D sub Connector 9 pin male CQM1H PLC connection CPM2C PLC connection CS CJ series peripheral connector LISTE Peripheral port lh Le D sub Connector 9 pin female Recommended cable CS1W CN226 626 Using a CQM1 CIFO02 Cable USB type A plug male USB type A plug male CS1W CIF31 D sub Connector 9 pin male CQM1H PLC connection CPM2C PLC connection
7. are changed or when significant construction changes are made However some specifica tions of the Product may be changed without any notice When in doubt spe cial part numbers may be assigned to fix or establish key specifications for your application Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product Errors and Omissions Information presented by Omron Companies has been checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions OMRON AUTOMATION 8 SAFETY OMRON INDUSTRIAL AUTOMATION THE AMERICAS HEADQUARTERS Schaumburg IL USA e 847 843 7900 e 800 556 6766 e www omron247 com OMRON CANADA INC HEAD OFFICE OMRON ARGENTINA SALES OFFICE Toronto ON Canada 416 286 6465 866 986 6766 e www omron247 com Cono Sur e 54 11 4783 5300 OMRON ELECTRONICS DE MEXICO HEAD OFFICE OMRON CHILE SALES OFFICE M xico DF 52 55 59 01 43 00 e 001 800 556 6766 mela amp omron com Santiago 56 9 9917 3920 OMRON ELECTRONICS DE MEXICO SALES OFFICE OTHER OMRON LATIN AMERICA SALES Apodaca N L e 52 81 11 56 99 20 001 800 556 6766 mela omron com 54 11 4783 5300 OMRON ELETR NICA DO BRASIL LTDA HEAD OFFICE S o Paulo SP Brasil e 55 11 2101 6300 e www omron com br OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands e Tel 31 0 23 568 13 00 Fax
8. detection if it is being used by your software With the CX Programmer auto baud rate detection can be turned OFF by clearing the selection for it on the Network Settings dialog box l Verifying the Allocated Communications Port The communications port COM port being used by the Conversion Cable can be verified with the following procedure The actual verification procedure depends on the operating system This example shows the procedure for Windows XP 1 Open the Control Panel open the System folder and click the Hardware tab 2 Click the Device Manager button 3 Click the symbol to the left of the Ports COM amp LPT device icon to display the contents of that folder Verify that there is an entry for the OMRON CS1W CIF3 USB Serial Port COML device A communications port name will appear in parentheses This is the communications port being used by the Conversion Cable Device Manager File Action View Help e mfa m5mmae El OMRON PC d Computer Disk drives Display adapters 81 2 DVD CD ROM drives amp amp 93 Floppy disk controllers Floppy disk drives 5 Human Interface Devices Sy IDE ATA ATAPI controllers Se Keyboards Mice and other pointing devices 3 Monitors i Network adapters 4 Ports COM amp LPT y Communications Port COM1 Proc 0 Sound video and game controllers System devices z Universal Serial Bus controllers Intel R 82801FB FBM USB Universal H
9. f Setoff Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice g Definitions As used herein including means including without limitation and Omron Compa nies or similar words mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof Certain Precautions on Specifications and Use 1 Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product This information by itself is not sufficient for a complete determination of the suitability of the Prod uct in combination with the end product machine system or other application or use Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application product or system Buyer shall take application responsibility in all cases but the following is a non exhaustive list of applications for which particular attention must be given i Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document ii Use in consumer products or any use in significant quant
10. headings appear in the left column of the manual to help you locate different types of information Note Indicates information of particular interest for efficient and convenient operation of the product 1 2 3 1 Indicates lists of one sort or another such as procedures checklists etc O OMRON 2003 All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means mechanical electronic photocopying recording or otherwise without the prior written permission of OMRON No patent liability is assumed with respect to the use of the information contained herein Moreover because OMRON is constantly striving to improve its high quality products the information contained in this manual is subject to change without notice Every precaution has been taken in the preparation of this manual Nevertheless OMRON assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained in this publication TABLE OF CONTENTS TABLE OF CONTENTS NOTICE iria Hte dus Het o EA d A 2 OMRON Product References sssssssssssseee enne 2 VISUAL AOS asta 2 TABLEOF CONTENTS 100 Aci 3 About this Manual rasa 4 PREGAWTIONS capas 5 Overview and COMPONGINS ui pbi iris 8 CV EIN OW C15 fecisti t E RA A ATIN A ATT 8 Appearance and Component Names sse nennen 8 PACKING EIS
11. including customs duties and sales excise use turnover and license taxes shall be charged to and remitted by Buyer to Omron Financial If the financial position of Buyer at any time becomes unsatisfactory to Omron Omron reserves the right to stop shipments or require satisfactory security or payment in advance If Buyer fails to make payment or otherwise comply with these Terms or any related agreement Omron may without liabil ity and in addition to other remedies cancel any unshipped portion of Prod ucts sold hereunder and stop any Products in transit until Buyer pays all amounts including amounts payable hereunder whether or not then due which are owing to it by Buyer Buyer shall in any event remain liable for all unpaid accounts Cancellation Etc Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses Force Majeure Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control including earthquakes fires floods strikes or other labor disputes shortage of labor or materials accidents to machinery acts of sabotage riots delay in or lack of transportation or the requirements of any government authority Shipping Delivery Unless otherwise expressly agreed in writing by Omron a Shipments shall be by a carrier selected by Omron Omron will not drop ship except in break down situations b Such carrier sh
12. must be used for the DC power supplies providing the communications power supply and I O power supplies 3 CS1W CIF31 USB Serial Conversion Cables complying with EC Directives also conform to the Common Emission Standard EN61000 6 4 Radiated emission characteristics 10 m regulations may vary depending on the configuration of the control panel used other devices connected to the control panel wiring and other conditions You must therefore confirm that the overall machine or equipment complies with EC Directives Overview and Components Overview and Components Overview The CS1W CIF31 USB Serial Conversion Cable connects an OMRON PLC Programmable Controller or PT Programmable Terminal to a personal computer s USB port The cable can be used once the required drivers on the provided CD ROM have been installed in the personal computer The Conversion Cable can be used with OMRON PLC PT software such as the CX Programmer which use the CX Server or FinsGateway as a communications driver as well as other OMRON Software such as the DeviceNet Configurator Appearance and Component Names l D sub Connector Cable e CS1W CIF31 USB Connector to D sub Connector USB connector D Sub 9 pin connector male A plug connector male EJ 0 EE JE LED Indicators Indicator Color Status Description TD Yellow Flashing Data is being sent from the USB Serial Conversion Cable OFF Data is not being sen
13. oo in ciu A ie mn ALL n UM 9 D sub Connector Cable CS1W CIF31 sse 9 MD ECIICATONS oi ERE DO o o dete 10 Compatible Operating Systems ssssssssssssseseenennene enne nnns 10 Compatible Software Applications sessssseeseeeeeeen eene 10 Compatible PLCs PTs and Programmable Relay sss 11 Connection Configurations sess enne nnns enn 12 General Specifications eeessssssssssssesesseeene enne entente 13 BTE TIR ESI AAA A E E E PONE POSU E 14 D sub Connector Cable esses enne nennen nennen nenas 14 System COMMOUFALON cc toca tear a Eten aret Stu pia fa ed o eet erp E fias 15 GS CJ series PL OS ue inde 15 GsS rieS PLCS 17 CVM1 and CV series PLCS cooccccccccinonnonoccconcccnonano nn n nano cc ronca rra 20 PTS NS and NT Series ri n een att e ette dd 21 Programmable Relay ZEN ooooocccconnoccccconocccccnnnoncccnnnoncncnnnoncncnnnnnnncnn no nn ncnnnnncc cnn nnncnnnns 21 USB to PLC PT Connection Tables meine 22 Connecting with the CS1W CIF31 D sub Connector Cable 22 Application Procede ba bee o baa 27 Cable Connecilons simio ici 28 Connecting the Cable srar aiiai ener nennen ennt nns nr nenne 28 InstallidriheDIVSTS TTE RP MELLE PIE 29 Uninstalling the DIINBIS iaa 33 Connecting Online from the CX Programmer cesse
14. written permission of Omron Notwithstanding any charges to Buyer for engineering or tooling all engineering and tooling shall remain the exclusive property of Omron All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party Export Controls Buyer shall comply with all applicable laws regulations and licenses regarding i export of products or information iii sale of products to forbidden or other proscribed persons and ii disclosure to non citizens of regulated technology or information Miscellaneous a Waiver No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron b Assignment Buyer may not assign its rights hereunder without Omron s written consent c Law These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products without regard to conflict of law princi ples d Amendment These Terms constitute the entire agreement between Buyer and Omron relating to the Products and no provision may be changed or waived unless in writing signed by the parties e Severability If any provi sion hereof is rendered ineffective or invalid such provision shall not invalidate any other provision
15. 31 0 23 568 13 88 www industrial omron eu Cat No n Note Specifications are subject to change O 2013 Omron Electronics LLC Printed in U S A
16. 36 Using the several CS1W CIF31 oooocccccccononccccnccncnnnnnnananancnnncnnnnnnnanannnnnnnns 40 Revision AI E DP 41 Mn A A lg grs 42 About this Manual About this Manual Thank you for purchasing the CS1W CIF31 USB Serial Conversion Cable The CS1W CIF31 USB Serial Conversion Cable connects an OMRON PLC or PT to a personal computer s USB port Please read this manual carefully and be sure you understand the information provided before attempting to install or operate the USB Serial Conversion Cables Be sure to read the precautions provided in the following section Precautions provides general precautions for using the USB Serial Conversion Cables and related devices Overview and Components describes the parts of the USB Serial Conversion Cables and gives an overview of their application Packing Lists shows the various items that come with the USB Serial Conversion Cables Specifications provides the hardware and software specifications Dimensions shows external cable dimensions System Configuration shows the application of the USB Serial Conversion Cables with various models of PLC USB to PLC PT Connection Tables lists the possible combinations of Cables Units and ports that can be used Application Procedure gives an overview of the steps required to use USB Serial Conversion Cables DIP Switch Settings and Cable Connections describes switch settings and cable connections Installing the Drivers tells how to inst
17. B FBM USB Universal Host Controller 265A Intel R 82801FB FBM USB Universal Host Controller 265B Intel R 82801FB FBM USB2 Enhanced Host Controller 265C OMRON USB HS Serial Converter USB Composite Device USB Root Hub 2 Click the Port Settings tab OMRON CS1W CIF3 USB Serial Port COM3 Properties 2 X AAA General Port Settings Driver Details Bits per second 3600 Data bits 8 Parity None Stop bits 1 Elow control None Restore Defaults 38 Connecting Online from the CX Programmer 3 Click the Advanced button The following window will be displayed Advanced Settings for COM3 CoMpotNumber M USB Transfer Sizes Cancel Select lower settings to correct performance problems at low baud rates Defaults Select higher settings for faster performance Receive Bytes leq Transmit Bytes les BM Options Miscellaneous Options Select lower settings to correct response problems Serial Enumerator Latency Timer msec 16 Serial Printer Cancel If Power Off Timeouts Event On Surprise Removal Minimum Read Timeout msec e Set RTS On Close Minimum Write Timeout msec f Disable Modem Ctrl At Startup 4 Select the new COM port number from the COM Port Number list 5 Click the OK button to change the COM port used by the Conversion Cable 39 Using More than One Conversion Cable Using More than O
18. CPM2A and SRM1 USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin COM1 CIFO2 C series Not necessary C series Peripheral bus female Length 3 3 m peripheral peripheral Toolbus or Host link SYSWAY See note D sub 9 pin XW2Z 200S CV D sub 9 pin Not necessary RS 232C Host link female 500S CV male D sub 9 pin SYSWAY Length 2 or 5 m female D sub 9 pin XW2Z 200S V D sub 9 pin Not necessary female 500S V male Length 2 or 5 m Note The host link mode can be used in all of these PLCs but the peripheral bus mode cannot be used in CPM2 or 5 digits long e C200H C1000H and C2000H CPU Units PLCs that have a 9 as the 4 digit of the lot number The lot number may be 4 USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 sub 9 pin ICQM1 CIF02 C series C series C200H IP007 Built in peripheral port Host link female Length 3 3 m eripheral eripheral SYSWAY 23 USB to PLC PT Connection Tables 24 e CQM1H CPU Units USB Cable 1 Cable 2 Unit s port Serial Conve
19. THE PRODUCTS BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or oth erwise of any intellectual property right c Buyer Remedy Omron s sole obli gation hereunder shall be at Omron s election to i replace in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof the non complying Product ii repair the non complying Product or iii repay or credit Buyer an amount equal to the purchase price of the non complying Product provided that in no event shall Omron be responsi ble for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were prop erly handled stored installed and maintained and not subject to contamina tion abuse misuse or inappropriate modification Return of any Products by Buyer must be approved in writing by Omron before shipment Omron Compa nies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environ ments Any advice recommendations or information given orally or in writing are not to be construed as an
20. USB Serial Conversion Cable User s Manual OMRON USB Serial Conversion Cable CS1W CIF31 User s Manual TABLE OF CONTENTS Notice OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual The following conventions are used to indicate and classify precautions in this manual Always heed the information provided with them Failure to heed precautions can result in injury to people or damage to property A DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury N WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury A Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or property damage OMRON Product References Visual Aids All OMRON products are capitalized in this manual The word Unit is also capitalized when it refers to an OMRON product regardless of whether or not it appears in the proper name of the product The abbreviation Ch which appears in some displays and on some OMRON products often means word and is abbreviated Wd in documentation in this sense The abbreviation PLC means Programmable Controller PC is used however in some Programming Device displays to mean Programmable Controller The following
21. WAY Length 2 or 5 m 25 pin female CV500 LK201 Port 2 Full duplex mode USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin XW2Z 200S V D sub 9 pin Not necessary RS 232C Host link female 500S V male D sub SYSWAY Length 2 or 5 m O pin female E PTs NS or NT Series USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin XW2Z S002 D sub 9 pin Not necessary RS 232C Host link female Length 2 m male D sub SYSWAY 9 pin female Programmable Relay ZEN USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin ZEN CIFO1 Personal Not necessary Personal female Length 2 m Computer Computer Connector ort Application Procedure Application Procedure This section explains how to connect a PLC CPU Unit to a personal computer with a USB Serial Conversion Cable Use the procedure below when connecting a PLC CPU Unit and personal computer The Conversion Cable uses one of the computer s COM ports for communications When communicating with a PLC through a Conversion Cable set the communications port COM port number used by the s
22. all act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer c All sales and shipments of Products shall be FOB shipping point unless oth erwise stated in writing by Omron at which point title and risk of loss shall pass from Omron to Buyer provided that Omron shall retain a security inter est in the Products until the full purchase price is paid d Delivery and shipping dates are estimates only and e Omron will package Products as it deems proper for protection against nor mal handling and extra charges apply to special conditions Claims Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original trans portation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed Warranties a Exclusive Warranty Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron or such other period expressed in writing by Omron Omron disclaims all other warranties express or implied b Limitations OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED ABOUT NON INFRINGEMENT MERCHANTABIL 14 15 16 17 18 ITY OR FITNESS FOR A PARTICULAR PURPOSE OF
23. all the software drivers Uninstalling the Drivers tells how to uninstall the software drivers Connecting Online from the CX Programmer tells how to connect to a PLC or PT from a computer running the CX Programmer AX WARNING Failure to read and understand the information provided in this manual may result in personal injury or death damage to the product or product failure Please read each section in its entirety and be sure you understand the information provided in the section and related sections before attempting any of the procedures or operations given PRECAUTIONS PRECAUTIONS This section provides general precautions for using the USB Serial Conversion Cable and related devices The information contained in this section is important for the safe and reliable application of the USB Serial Conversion Cable You must read this section and understand the information contained before attempting to set up or operate a USB Serial Conversion Cable and PLC system Intended Audience This manual is intended for the following personnel who must also have knowledge of electrical systems an electrical engineer or the equivalent Personnel in charge of purchasing FA devices Personnel in charge of designing FA systems Personnel in charge of managing FA systems and facilities ll General Precautions The user must operate the product according to the performance specifications described in the operation manual
24. amendment or addition to the above warranty See http www omron247 com or contact your Omron representative for pub lished information Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Indemnities Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities losses claims costs and expenses including attorney s fees and expenses related to any claim inves tigation litigation or proceeding whether or not Omron is a party which arises or is alleged to arise from Buyer s acts or omissions under these Terms or in any way with respect to the Products Without limiting the foregoing Buyer at its own expense shall indemnify and hold harmless Omron and defend or set tle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party Property Confidentiality Any intellectual property in the Products is the exclu Sive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the
25. atest driver software for your device unless you ve disabled this feature in your device installation settings Browse my computer for driver software Locate and install driver software manually 5 The following window will be displayed 31 Installing the Drivers Fr Go Update Driver Software OMRON USB Serial Converter Drivers Browse for driver software on your computer Search for driver software in this location E win2000_XP_Vista_7 Browse Y Include subfolders gt Let me pick from a list of device drivers on my computer This list will show installed driver software compatible with the device and all driver software in the same category as the device Gana 6 Insert the CD ROM containing the driver the CD ROM is in the same package as the Conversion Cable into the computer s CD ROM drive Click the Browse button select the following directory of the CD ROM and click the OK button Windows2000 XP Vista 7 win2000 XP Vista 7 Windows98 Me Win98 Me Click the Next button in Please choose your search and installation options window 7 Click the nstall this driver software anyway in Windows Security window W Windows Security Windows can t verify the publisher of this driver software Don t install this driver software You should check your manufacturer s website for updated driver software for your device Install this driver software anyway Only install driver so
26. conditions proposed in Buyers purchase order or other documents which are inconsistent with or in addition to these Terms Prices Payment Terms All prices stated are current subject to change with out notice by Omron Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders Payments for Products are due net 30 days unless otherwise stated in the invoice Discounts Cash discounts if any will apply only on the net amount of invoices sent to Buyer after deducting transportation charges taxes and duties and will be allowed only if i the invoice is paid according to Omron s payment terms and ii Buyer has no past due amounts Interest Omron at its option may charge Buyer 1 1 2 interest per month or the maximum legal rate whichever is less on any balance not paid within the stated terms Orders Omron will accept no order less than 200 net billing Governmental Approvals Buyer shall be responsible for and shall bear all costs involved in obtaining any government approvals required for the impor tation or sale of the Products Taxes All taxes duties and other governmental charges other than general real property and income taxes including any interest or penalties thereon imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture production sale delivery importa tion consumption or use of the Products sold hereunder
27. driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed Search removable media floppy CD ROM v Include this location in the search C win2000 XP Vista 7 v O Dont search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware lt Back J Next gt _ Cancel 40 Revision History Revision History A manual revision code appears as a suffix to the catalog number on the front cover of the manual Cat No W417 E1 04 Revision code The following table outlines the changes made to the manual during each revision Page numbers refer to the previous version Revised content February 2003 Original production 02 October 2006 Page 7 Changed EMI standard number of EC Directives Page 30 Changed the reference directory for the driver file Page 37 Add section on using more than one Conversion Cable 03 July 2007 Page 10 Changed the compatible operating systems Page 29 Changed information on installing the drivers October 2010 Revisions associated with support of 64 bit OS 41 Index 42 communications port CANGING EN 38 VOI dr as did 37 component names ni eaaa aan E ad nie dadas 8 configuration PLC PT conn
28. e Communications Port Limitations with the NT Support Tool 1 Version 4 00 and Earlier Versions Only communications ports COM1 and COM can be used Always change the communications port allocation for this device to COM1 or COM2 in the Microsoft Windows Device Manager see note 1 and specify that port in the NT Support Tool s communications settings Once the communications port is specified correctly in the Windows Device Manager and the NT Support Tool s communications settings data such as screen data can be downloaded to the PT or uploaded from the PT through the USB Serial Conversion Cable Note In most personal computers COM1 is allocated to the RS 232C port and communications port COM2 can be allocated to the Conversion Cable Refer to Changing the Allocated Communications Port on page 38 for details on changing the communications port Furthermore if there is another driver using the allocated port that driver must be uninstalled 2 Version 4 60E and Later Versions Any communications port between COM 1 and COMB8 can be used Check the NT Support Tool s communications settings and verify that the communications port allocated to the Conversion Cable is also specified in the NT Support Tool 10 Specifications Limitations when Using the NT Support Tool s System Installer 1 Windows 98 and Windows Me The system program cannot be downloaded to the PT through the USB Serial Conversion Cable 2 Windows 2000 Windows XP Windo
29. e OMRON USB HS Serial Converter has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation 6 The following window will be displayed if the driver was installed properly Click the Finish button Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for 2 OMRON USB HS Serial Converter Click Finish to close the wizard 7 When the Finish button is clicked in step 6 the installation of the USB Serial Port driver will be automatically started Follow the same procedure in steps 1 through 6 to install the USB Serial Port driver Driver installation is completed after installation of the USB Serial Port driver 8 When the installation is completed the communications port COM port number will be automatically allocated Refer to the Verifying the Allocated Communications Port on page 37 for how to confirm the allocated communications port number 30 Installing the Drivers lt Windows 7 gt 1 4 Insert this cable to the USB port of your computer The
30. e female link SYSWAY D sub 9 pin XW2Z 200S V RS 232C Not necessary Host link female 500S V D sub 9 pin SYSWAY Length 2 or 5 m male 22 USB to PLC PT Connection Tables e CS CJ series Serial Communications Board or Unit USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin XW2Z 200S CV RS 232C Not necessary RS 232C Host link female 500S CV D sub 9 pin D sub 9 pin SYSWAY Length 20r5 m imale female D sub 9 pin XW2Z 200S V RS 232C Not necessary female 500S V D sub 9 pin Length 2 or 5 m male e Customizable Counter Unit USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin CS1W CN226 626 CS CJ series Not necessary CS CJ series Peripheral bus female Length 2 0r6 m peripheral peripheral Toolbus D sub 9 pin XW2Z 200S V D sub 9 pin D sub 9 pin CS1W CN118 CS CJ series Peripheral bus female 500S V male female Length 0 1 m peripheral Toolbus Length 2 or 5 m F C series Units Note In this table the C series refers to the C200HS C200HX HG HE C200H C1000H C2000H CQM1 CPM1 CPM1A CPM2A SRM1 CQM1H and CPM2C e C200HS C200HX HG HE CQM1 CPM1 CPM1A
31. ections C200HS C200HX HG HE C200H C1000H 2000H CQM1 CPM1 CPM1A GPM2A and SRMfT ice hee de te ere t eredi e aen o enn due ads 17 GCOMTH GPMO2G itis ese tetas reis etes en ttes 18 CS GJ series PEGOS 2 s etie tek e iere eie ene n 15 G sen s PECES to m eel DM E mi 17 GVMil and GV seri s PECS 3 anda teta aa 20 NS series and NT series PTS ccccccccccccsssssteseeeeececseseeaeceeeeseeeseaeaeseseeeeserseaees 21 Programmable Relay ZEN sse nnne nennen 21 CX Programmer communications POr eea E TEI ener ennemi nennen nns 36 D CIMENSIONS 3 ui A t e es EL nte te He dde 14 drivers hlc 29 ninstalling 2 5 cente ott bee tne ibis 33 40 O operating system applicable ooooocninninnnnnnnnncnnnnnnononnnccnccccnnrrnnn rra cnn rca cnn 10 OVA de de al es qu cot a one cat af tob oes SA 8 P PLOS applicable E 11 PTS PPC ita 11 S software applicable sssesssssssssseseeseeeeee enne entere nnn nennen nns 10 Terms and Conditions of Sale OMRON Ti Qa 9 10 11 12 Offer Acceptance These terms and conditions these Terms are deemed part of all quotes agreements purchase orders acknowledgments price lists catalogs manuals brochures and other documents whether electronic or in writing relating to the sale of products or services collectively the Products by Omron Electronics LLC and its subsidiary companies Omron Omron objects to any terms or
32. eries peripheral port Conversion Cable OR B E CS1W CIF31 USB CQM1H CIFO2 Programming Conversion Cable Device Connecting Cable for a C series peripheral port CS1W CN118 I RS 220 to Cele seties peripheral CO port Conversion Cable D OR i YE XW2Z O00 Programming Device Connecting Cable for RS 232C l am EI F CS CJ series Units e CS CJ series CPU Units USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin CS1W CN226 626 CS CJ series Not necessary CS CJ series Peripheral bus female Length 2 or 6 m peripheral peripheral Toolbus or Host link SYSWAY D sub 9 pin CQM1 CIF02 C series C series CS1W CN114 CS CJ series Host link female Length 3 3 m peripheral peripheral Length 5 cm peripheral SYSWAY D sub 9 pin XW2Z 200S OV D sub 9 pin D sub 9 pin CS1W CN118 CS CJ series Peripheral bus female 500S CV male female Length 0 1 m peripheral Toolbus or Host Length 2 or 5 m link SYSWAY D sub 9 pin XW2Z 200S V D sub 9 pin D sub 9 pin CS1W CN118 CS CJ series Host link female 500S V male female Length 0 1 m peripheral SYSWAY Length 2 or 5 m D sub 9 pin XW2Z 200S CV RS 232C Not necessary RS 232C Peripheral bus female 500S CV D sub 9 pin D sub 9 pin Toolbus or Host Length 2 or 5 m mal
33. following message will be displayed in the status area of the Task bar Device driver software was not successfully installed s lb Device driver software was not successfully installed Click here for details Click the System properties of Computer to start the Device Manager Right click on the OMRON USB Serial Converter Drivers under the Other devices Then click the Update Driver Software from the right click menu PEINE io TAO oie File Action View Help es im O B re ts 4 iy OMRON PC b 4S Computer x Disk drives E Display adapters gt lj DVD CD ROM drives vid Floppy disk drives 3 Floppy drive controllers gt Uy Human Interface Devices lt q IDE ATA ATAPI controllers o Keyboards gt Pl Mice and other pointing devices o M Monitors a Network adapters i Other devices Ji OMRON USB Serial Tf Ports COM amp LPT Update Driver Software A Processors Disable Sound video and game contra Uninstall i System devices Universal Serial Bus controllers Scan for hardware changes Properties Launches the Update Driver Software Wizard for the The following window will be displayed Click the Browse my computer for driver software i Update Driver Software OMRON USB Serial Converter Drivers How do you want to search for driver software gt Search automatically for updated driver software Windows will search your computer and the Internet fcr the l
34. ftware obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information i v See details 8 The following window will be displayed when the driver was installed properly Click the Close button eJ Update Driver Software OMRON USB HS Serial Converter Windows has successfully updated your driver software Windows has finished installing the driver software for this device OMRON USB HS Serial Converter I Close 9 Next right click on the USB Serial Port of the Device Manager and click the Update Driver Software from the right click menu Follow the same procedure in steps 4 through 8 to install the USB Serial Port driver Driver installation is completed after installation of the USB Serial Port driver 10 When the installation is completed the communications port COM port number will be automatically allocated Refer to the Verifying the Allocated Communications Port on page 37 for how to confirm the allocated communications port number 32 Uninstalling the Drivers Uninstalling the Drivers Use the following procedure to delete uninstall the drivers for the USB Serial Conversion Cable lt Windows Vista 7 gt T 2 3 Connect the Conversion Cable to computer Click System properties of Computer to start the Device Manager Click the OMRON CS1W CIF3 USB Serial Port COMS3 in the Ports COM amp LPT and click
35. hanisms Do not place anything on the cable Do not bend the cable past it s normal bending radius or pull on the cable Touch the Unit only after touching a grounded metal object to release static electricity from your body Disconnect or connect the cable only after confirming that communications are not in progress Do not quickly and repeatedly connect and disconnect the USB connector Doing so may cause the computer to malfunction elt may take some time for the computer to detect the cable after the cable is connected This is not a malfunction Do not connect the RS 232C connector on the CS1W CIF31 Cable D sub type directly to the RS 232C or RS 422 485 connector on the PLC The cable may malfunction Do not connect this cable to a USB hub connect it directly to a USB connector on the computer The cable may malfunction Do not extend the USB portion of this cable with an extension cable The cable may malfunction Set the communications port COM port number used by the software to the communications port COM port number allocated to the Conversion Cable A Caution Perform wiring so that the power supply wires are not exposed and do not come into contact with any metal parts Contact with metal parts may cause a fire PRECAUTIONS BEC Directives e Applicable Directives EMC Directives Low Voltage Directive e Concepts EMC Directives OMRON devices that comply with EC Directives also c
36. ities iii Energy control systems combustion systems railroad systems aviation Systems medical equipment amusement machines vehicles safety equip ment and installations subject to separate industry or government regulations iv Systems machines and equipment that could present a risk to life or prop erty Please know and observe all prohibitions of use applicable to this Prod uct NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON S PRODUCT IS PROP ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM Programmable Products Omron Companies shall not be responsible for the user s programming of a programmable Product or any consequence thereof Performance Data Data presented in Omron Company websites catalogs and other materials is provided as a guide for the user in determining suitabil ity and does not constitute a warranty It may represent the result of Omron s test conditions and the user must correlate it to actual application require ments Actual performance is subject to the Omron s Warranty and Limitations of Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our prac tice to change part numbers when published ratings or features
37. n You are about to uninstall all FTDI drivers for VID 0x0590 and all PIDs e Do you want to continue 7 FTDI Clean Utility V1 0 window will be displayed Confirm that Status System clean completed is displayed VID Hex ma PID Hex Windows XP Status System clean completed 8 FTDI Clean Utility V1 0 window will be displayed Click the Exit button This completes the deletion uninstallation of the Conversion Cable s drivers Windows 98 Me gt 1 Disconnect the Conversion Cable from the computer 2 Select Add Remove Programs from the Control Panel 3 Select OMRON USB to Serial Converter Drivers and click the Delete button The following window will be displayed FTDI Uninstaller ersion 2 1 xj If your USB device is connected please unplug it now Press Continue to uninstall the drivers or Cancel to quit Continue 4 Click the Continue button When the drivers have been successfully deleted the message Uninstall complete press Finish to exit will be displayed 34 Uninstalling the Drivers FTDI Uninstaller Version 2 1 x Uninstalling YID_05904PID_0036 Deleting registry entries Deleting files Uninstall complete press Finish to exit Continue 5 Click the Finish button This completes the deletion uninstallation of the Conversion Cable s drivers 35 Connecting Online from the CX Programmer Connecting Online from the CX Programmer
38. ne Conversion Cable The operating system recognizes USB Serial Conversion Cables individually If a second Conversion Cable is connected after the driver has been installed driver installation will be requested again Install the driver from the CD ROM again If you do not own the CD ROM and will use more than one Conversion Cable copy the win2000 XP Vista 7folder from the CD ROM to a folder on your hard disk and select this folder Note Use the following directory for Windows 98 or Me Win98 Me 1 Copy the win2000 XP Vista 7folder from the CD ROM to your hard disk the CD ROM is in the same package as the Conversion Cable 2 The following window will be displayed Select nstall from a list or specific location Advanced and click the Next button Found New Hardware Wizard This wizard helps you install software for OMRON USB Serial Converter Drivers If your hardware came with an installation CD 2 or floppy disk insert it now What do you want the wizard to do O Install the software automatically Recommended G Install from a list or specific location Advanced Click Next to continue lt Back Nest Cancel 3 Click the Browse button next to the nclude this location in the search field select the win2000 XP Vista 7folder copied from CD ROM onto your hard disk and click the Next button Found New Hardware Wizard Please choose your search and installation options Y Search for the best
39. ns Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin XW2Z 200S CV D sub 9 pin Not necessary RS 232C Host link female 500S CV male D sub SYSWAY Length 2 or 5 m 9 pin D sub 9 pin XW2Z 200S V D sub 9 pin Not necessary female female 500S V male Length 2 or 5 m 25 USB to PLC PT Connection Tables 26 l CVM1 and CV series e CVM1 and CV series CPU Units USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin D sub 25 pin female D sub 25 pin D sub 25 pin CV500 CIFO1 CV series ICV series Peripheral bus female to D sub 9 pin male female Length 6 m peripheral peripheral Toolbus female adapter D sub 9 pin XW2Z 200S V D sub 9 pin Not necessary RS 232C Host link female 500S V male D sub SYSWAY Length 2 or 5 m O pin female e CVM1 and CV series Host Link Units CV500 LK201 Port 1 Full duplex mode USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin KW2Z 200P V D sub 25 pin Not necessary RS 232C Host link female 500P V male D sub SYS
40. oftware to the communications port COM port number allocated to the Conversion Cable Connect the Cable s Connect the Conversion Cable to the computer s USB port and the CPU Unit s peripheral port or RS 232C port For details refer to Connecting the Cable on page 28 2 Install the communications driver The Conversion Cable s communications driver must be installed in the computer in order for the computer to use the Conversion Cable For details refer to nstalling the Driver on page 29 3 Turn ON the PLC s power Turn ON the PLC s power supply 4 Make an online connection to the CPU Unit through the computer software when using the CX Programmer Select the COM port in the CPU Unit from the CX Programmer and connect online For details refer to Connecting Online from the CX Programmer on page 36 MITE More than one USB Serial Conversion Cable can be used at a time so a single personal computer can be connected to several PLCs PTs through two or more COM ports When more than one Conversion Cable is being used connect the second and later Cables after the first Cable has been connected The communications driver is automatically installed for the second and later Cables so it is not necessary to install the driver a second time Each Cable must have its own unique COM port number Allocate a different COM port to each Cable 27 Cable Connections Cable Connections Connecting the Cable Connect the compu
41. onform to the related EMC standards so that they can be more easily built into other devices or the overall machine The actual products have been checked for conformity to EMC standards see the following note Whether the products conform to the standards in the system used by the customer however must be checked by the customer EMC related performance of the OMRON devices that comply with EC Directives will vary depending on the configuration wiring and other conditions of the equipment or control panel on which the OMRON devices are installed The customer must therefore perform the final check to confirm that devices and the overall machine conform to EMC standards Note Within the EMC Electromagnetic Compatibility standards the applicable EMS Electromagnetic Susceptibility standard is EN61000 6 2 and the applicable EMI Electromagnetic Interference standard is EN61000 6 4 10 m regulations Low Voltage Directive Always ensure that devices operating at voltages of 50 to 1 000 VAC and 75 to 1 500 VDC meet the required safety standards EN61131 2 Conformance to EC Directives The CS1W CIF31 USB Serial Conversion Cables comply with EC Directives Observe the following precautions to ensure that the machine or device in which the Conversion Cable is used complies with EC directives 1 The CS1W CIF31 USB Serial Conversion Cable must be installed within a control panel 2 Reinforced insulation or double insulation
42. or metal filings Locations subject to exposure to water oil or chemicals Locations subject to shock or vibration Provide proper shielding when installing in the following locations Locations subject to static electricity or other sources of noise Locations subject to strong electromagnetic fields Locations subject to possible exposure to radiation Locations near power supply lines PRECAUTIONS l Application Precautions Observe the following precautions when using the USB Serial Conversion Cable These cables are designed specifically to connect a personal computer to an OMRON PLC or PT Do not use them to connect any other devices and do not use a commercially available USB serial conversion cable in place of these cables Improper usage of these cables may result in damage to external devices the PLC or the PT Do not attempt to disassemble repair or modify any Units Touch a grounded metal object to discharge any static electricity before connecting the Conversion Cable to the PLC s connector a PLC Connecting Cable or the personal computer s USB port To avoid malfunctions due to noise do not route the Conversion Cable parallel or close to a high tension power line Tighten the D sub connector screws to a torque of 0 4 N m Either turn OFF the power supply to the computer or disconnect the cable from the USB connector before setting the DIP switch Always lock any connectors that are equipped with locking mec
43. ost Controller 2658 Intel R 82801FB FBM USB Universal Host Controller 2659 Intel R 82801FB FBM USB Universal Host Controller 265A Intel R 82801FB FBM USB Universal Host Controller 2658 Intel R 82801FB FBM USB2 Enhanced Host Controller 265C OMRON USB HS Serial Converter USB Composite Device USB Root Hub 37 Connecting Online from the CX Programmer ll Changing the Allocated Communications Port The communications port COM port being used by the Conversion Cable can be changed with the following procedure The actual change procedure depends on the operating system This example shows the procedure for Windows XP ETT HM If the new COM port is being used by another driver that driver must be uninstalled 1 Double click OMRON CS1W CIFS USB Serial Port COML in the Device Manager window E Device Manager File Action View Help e Fa m 3 lt R4Q amp 9 Computer Disk drives Display adapters DVD CD ROM drives 4 42 Floppy disk controllers i Floppy disk drives 83 Human Interface Devices Sy IDE ATA ATAPI controllers Se Keyboards Mice and other pointing devices Monitors 88 Network adapters JY Ports COM amp LPT y Communications Port COM1 TOCESSOrS Sound video and game controllers System devices H Universal Serial Bus controllers Intel R 82801FB FBM USB Universal Host Controller 2658 Intel R 82801FB FBM USB Universal Host Controller 2659 Intel R 82801F
44. r Unit connection CS CJ series peripheral connector D sub Connector 9 pin female Peripheral port Recommended cable CS1W CN226 626 Using a CQM1 CIF02 Cable USB type A plug male CS1W CIF31 D sub Connector 9 pin male CS CJ series PLC connection see note D sub Connector 9 pin female CS CJ series peripheral C series peripheral connector connector ES A ES Peripheral port Recommended cable AL CQM1 CIFO2 CS1W CN114 Note With a CS CJ series PLC the connection must be a host link connection 15 System Configuration Using a XW2Z 200S CV 500S CV or XW2Z 200S V 500S V Cable for an RS 232C Connection SB type A plug male CS1W CIF31 D sub Connector 9 pin male CS CJ series PLC connection Customizable Counter Unit connection D sub Connector D sub Connector A male 9 pin female Peripheral port XW2Z 200S CV 500S CV or D sub LL CS CJ series peripheral connector XW2Z 200S V 500S V See note 9 pin female CS1W CN118 Note With a CS CJ series PLC the connection must be a host link connection e Connecting to the RS 232C Port Using a XW2Z 200S CV 500S CV or XW2Z 200S V 500S V Cable for an RS 232C Connection D sub Connector CS CJ series PLC connection 9 pin male D sub Connector 9 pin male D sub Connector 9 pin f 9 pin female RS 232C port D sub Connector 9 pin female Recommended cable XW2Z 200S CV 500S CV or XW2Z 200S
45. ral peripheral Peripheral port peripheral connector D sub 9 pin CS1W CN226 626 CS CJ series Not necessary Host link female Length 2 or6m peripheral SYSWAY See note 2 D sub 9 pin XW2Z 200S CV D sub 9 pin D sub 9 pin CS1W CN118 CS Cu series RS 232C Host link female 500S CV male female Length 0 1 m periphera D sub 9 pin SYSWAY Length 2 or 5 m female D sub 9 pin XW2Z 200S CV D sub 9 pin D sub 9 pin CPM2C CN111 CS CJ series female 500S CV male female RS 232C port periphera Length 2 or 5 m connector D sub 9 pin XW2Z 200S V D sub 9 pin D sub 9 pin CS1W CN118 CS CJ series female 500S V male female Length 0 1 m periphera Length 2 or 5 m D sub 9 pin XW2Z 200S V D sub 9 pin D sub 9 pin CPM2C CN111 CS CJ series female 500S V male female RS 232C port periphera Length 2 or 5 m connector Note 1 The host link mode can be used in all of these PLCs but the peripheral bus mode cannot PLCs that have a 9 as the 4 digit of the lot number The lot number may be 4 or 5 digits long Note 2 be used in CPM2 Only host link mode can be used USB to PLC PT Connection Tables e C series Host Link Unit C200H LK201 V1 or C120 LK201 V1 Note The Host Link Unit cannot be used to connect a Programming Device such as the CX Programmer to a C200HX HG HE with the ZE suffix at the end of the model number
46. rsion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin CS1W CN226 626 CS CJ series Not necessary CS CJ series Peripheral bus female Length 2 or6 m peripheral peripheral Toolbus or Host link SYSWAY D sub 9 pin CQM1 CIF02 C series C series CS1W CN114 CS CJ series female Length 3 3 m peripheral peripheral Length 5 cm peripheral D sub 9 pin XW2Z 200S CV D sub 9 pin D sub 9 pin CS1W CN118 CS CJ series female 500S CV male female Length 0 1 m peripheral Length 2 orb m D sub 9 pin XW2Z 200S V D sub 9 pin D sub 9 pin CS1W CN118 CS CJ series Host link female 500S V male female Length 0 1 m peripheral SYSWAY Length 2 or5m D sub 9 pin XW2Z 200S CV D sub 9 pin Not necessary RS 232C Host link female 500S CV male D sub 9 pin SYSWAY Length 2 or 5m female D sub 9 pin XW2Z 200S V D sub 9 pin Not necessary female 500S V male Length 2 or5m e CPM2C USB Cable 1 Cable 2 Unit s port Serial Conversion communications Cable mode Model Connector Model Connector Connector Model Connector Network type CS1W CIF31 D sub 9 pin CQM1 CIF02 C series C series CS1W CN114 CS CJ series CS CJ series Peripheral bus female Length 3 3 m peripheral peripheral Length 5 cm peripheral peripheral Toolbus or Host link SYSWAY See note 1 D sub 9 pin CQM1 CIF02 C series C series CPM2C CN111 CS CJ series female Length 3 3 m periphe
47. s Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems railroad systems aviation systems vehicles combustion systems medical equipment amusement machines safety equipment and other systems machines and equipment that may have a serious influence on lives and property if used improperly This manual provides important information for using the CS1W CIF31 USB Serial Conversion Cable Be sure to read this manual before attempting to use the Conversion Cable and keep this manual close at hand for reference during operation A WARNING It is extremely important that a PLC and all PLC Units be used for the specified purpose and under the specified conditions especially in applications that can directly or indirectly affect human life You must consult with your OMRON representative before applying a PLC system to the above mentioned applications ll Operating Environment Precautions Do not use the USB serial Conversion Cable in the following places Locations subject to strong electromagnetic fields Locations subject to direct sunlight Locations subject to temperatures or humidity outside the range specified in the specifications Locations subject to condensation as the result of severe changes in temperature Locations subject to corrosive or flammable gases Locations subject to excessive dust or salts
48. shows the connection configurations that can be used to connect an OMRON PLC or PT to a personal computer s USB port 12 USB Serial Conversion Required adapters or cables Compatible Compatible PLCs Conversion Cable s serial PLC or PT and PTs Cable connector connector CS1W CIF31 D sub 9 pin CS1W CN226 626 CS CJ series CS CJ series D sub version male Programming Device Connecting Cable fora peripheral CQM1H and CS CJ series peripheral port and personal port CPM2C computer XW2Z 200 500S CV or XW2Z 200 500S V Programming Device Connecting Cable for an RS 232C port and personal computer CS1W CN118 RS 232C to CS CJ series peripheral port Conversion Cable CQM1 CIFO2 Programming Device Connecting Cable for a C series peripheral port and personal computer CS1W CN114 C series peripheral port to CS CJ series peripheral port Conversion Cable CQM1 CIF02 C series C200HS Programming Device Connecting Cable fora peripheral C200HX HG HE C series peripheral port and personal port CQM1 CPM1 computer CPM1A CPM2A and SRM1 RS 232C 9 pin to 25 pin adapter CV series CVM1 CV series peripheral CV500 CIF01 port Programming Device Connecting Cable for a CV series peripheral port and PC98 type personal computer XW2Z 200 500S CV or XW2Z 200 500S V RS 232C port PLCs CPU Unit Programming Device Connecting Cable for D sub 9 pin or Serial an RS 232C port and personal computer
49. t button 29 Installing the Drivers The following window will be displayed Select the Search for the best driver in there locations and check the Include this location in the search Found New Hardware Wizard Please choose your search and installation options x Y 9 Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found wil be installed Search removable media floppy CD ROM Z Include this location in the search E win2000_XP_Vista_7 y Browse O Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware lt Back ji Next gt J Cancel J 4 Insert the CD ROM containing the driver the CD ROM is in the same package as the Conversion Cable into the computer s CD ROM drive Click the Browse button select the following directory of the CD ROM and click the OK button Windows2000 XP Vista 7 win2000 XP Vista 7 Windows98 Me Win98 Me Click the Next button in the Please choose your search and installation options window 5 The following window will be displayed Click the Continue Anyway button to start installing the driver Hardware Installation The software you are installing for this hardwar
50. t from the USB Serial Conversion Cable RD Yellow Flashing The USB Serial Conversion Cable is receiving data OFF The USB Serial Conversion Cable is not receiving data Packing Lists Packing Lists D sub Connector Cable CS1W CIF31 Name Appearance CS1W CIF31 USB Connector to D sub Connector Conversion Cable Drivers On CD ROM User s Manual this manual On CD ROM in PDF format L1 Instruction Sheet A E Specifications Specifications Compatible Operating Systems Windows 98 ME 2000 XP Windows Vista 7 32bit 64bit Compatible Software Applications The compatible software applications communicate with the PLC using the CX Server or FinsGateway The following software applications use CX Server or FinsGateway Name Communications software CX Programmer CX Server FinsGateway is used for network communications CX Simulator FinsGateway CX Protocol CX Server FinsGateway is used for network communications CX Position FinsGateway CX Motion CX Server CX Process FinsGateway or CX Server NS Designer FinsGateway PLC Reporter FinsGateway The following software applications are also compatible DeviceNet Configurator NT Support Tool for Windows ZEN Support Software Ver 3 0 or later Software applications in CX On
51. ter and CPU Unit with one of the cable configurations shown in the USB to PLC PT Connection Table on page 22 28 Installing the Drivers Installing the Drivers When the USB Serial Conversion Cable is connected to the computer the operating system OS will recognize the Cable as a new device At this point the driver can be installed with the wizard The actual driver installation method depends on the OS being used Windows XP and Windows 7 are used in the examples in this section MITO The USB Serial Conversion Cables are compatible with Windows XP When you install the Conversion Cable s driver a warning message will appear indicating that the driver software has not passed Windows Logo testing but click Continue Anyway to proceed with the installation We have thoroughly tested the driver on Windows XP and verified that it operates properly The driver will not be installed properly if the installation process is cancelled before completion Normal communications may not be possible if the driver is not installed properly If the driver is not installed properly uninstall it refer to page 37 and then reinstall it correctly ATEN The USB Serial Conversion Cables are compatible with Windows Vista 7 When you install the Conversion Cable s driver a warning message will appear indicating that Windows can t verify the publisher of this driver software but click Continue Anyway to proceed with the installation We have thoroughly
52. tested the driver on Windows Vista and verified that it operates properly The driver will not be installed properly if the installation process is cancelled before completion Normal communications may not be possible if the driver is not installed properly If the driver is not installed properly uninstall it refer to page 37 and then reinstall it correctly lt Windows XP gt 1 The following window will be displayed Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Bead our privacy policy Can Windows connect to Windows Update to search for software O Yes this time only O Yes now and every time connect a device O No not this time Click Next to continue 2 Select the No not this time and click the Next button The following window will be displayed Found New Hardware Wizard This wizard helps you install software for OMRON USB Serial Converter Drivers If your hardware came with an installation CD S or floppy disk insert it now What do you want the wizard to do O Install the software automatically Recommended Install from a list or specific location Advanced Click Next to continue lt Back Next gt J Cancel 3 Select the nstall from a list or specific location Advanced and click the Nex
53. the Uninstall button Confirm Device Uninstall window will be displayed Select Delete the driver software for the device and click the OK button Confirm Device Uninstall as OMRON CS1W CIF3 USB Serial Port COM3 Waming You are about to uninstall this device from your system Y Delete the driver software for this device Click the OMRON USB Serial Converter in the Universal Serial Bus contollers and click the Uninstall button Confirm Device Uninstall window will be displayed Select Delete the driver software for the device and click the OK button Confirm Device Uninstall OMRON USB HS Serial Converter Waming You are about to uninstall this device from your system Y Delete the driver software for this device Cancel This completes the deletion uninstallation of the Conversion Cable s drivers lt Windows 2000 XP gt 1 2 4 Disconnect the Conversion Cable from the computer Double click the Ftclean exe in the win2000 XP Vista 7folder from the CD ROM to start the FTDI Clean Utility V1 0 Select the Other from the pull down menu of the VID Hex and enter 0590 in the right field Then click the Clean System button FTDI Clean Utility V1 0 FTDI d Chi Sk ip VID Hex Other x d Clean System PID Hex TP Exit Status Ready Information window will be displayed Click the OK button 33 Uninstalling the Drivers Informatio
54. ws Vista and Windows 7 Only communications ports COM1 and COM can be used Always change the communications port allocation for this device to COM1 or COM2 in the Microsoft Windows Device Manager see note 1 and specify that port in the NT Support Tool s communications settings Once the communications port is specified correctly in the Windows Device Manager and the NT Support Tool s communications settings the system program can be downloaded to the PT through the USB Serial Conversion Cable Note In most personal computers COM1 is allocated to the RS 232C port and communications port COM2 can be allocated to the Conversion Cable Refer to Changing the Allocated Communications Port on page 38 for details on changing the communications port Furthermore if there is another driver using the allocated port that driver must be uninstalled Compatible PLCs PTs and Programmable Relay The following OMRON PLCs PTs and Programmable Relay are supported by the compatible software applications PLCs CS CJ series C series see note 1 and CVM1 CV series PT NS series and NT series Programmable Relay ZEN see note 2 Note 1 The following C series PLCs are supported C200HS C200HX HG HE C200H C1000H C2000H COM1 CPM1 CPM1A CPM2A SRM1 CQM1H and CPM2C Note 2 The ZEN Programmable Relay is supported only if ZEN Support Software Ver 3 0 or later is used 11 Specifications Connection Configurations The following table