1. TOUCHSCREEN This operator interface utilizes a resistive analog touchscreen for user input The unit will only produce an audible tone beep when a touch on an active touchscreen cell is sensed The touchscreen is fully functional as soon as the operator interface is initialized and can be operated with gloved hands KEYPAD The G306 keypad consists of five keys that can be used for on screen menus TROUBLESHOOTING YOUR G306 If for any reason you have trouble operating connecting or simply have questions concerning your new G306 contact Red Lion s technical support For contact information refer to the back page of this bulletin for phone and fax numbers EMAIL techsupport redlion net Web Site http www redlion net BATTERY amp TIME KEEPING WARNING EXPLOSION HAZARD THE AREA MUST BE KNOWN TO BE NON HAZARDOUS BEFORE SERVICING REPLACING THE UNIT AND BEFORE INSTALLING OR REMOVING I O WIRING AND BATTERY WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED AND THE AREA IS KNOWN TO BE NON HAZARDOUS A battery is used to keep time when the unit is without power Typical accuracy of the G306 time keeping is less than one minute per month drift The battery of a G306 unit does not affect the unit s memory all configurations and data is stored in non volatile memory CAUTION RISK OF ELECTRIC SHOCK The inverter board attached to the mounting plate supplies the high
2. CONNECTIONS RS485 2 WIRE CONNECTIONS TxB TxA TxA TxEN OC TxEN OC GND RxA 6 enp i Note All Red Lion devices connect A to A and B to B except for Paradigm devices Refer to www redlion net for additional information DH485 COMMUNICATIONS The G306 s RS422 485 COMMS port can also be used for Allen Bradley DH485 communications WARNING DO NOT use a standard DH485 cable to connect this port to Allen Bradley equipment A cable and wiring diagram are available from Red Lion G3 to AB SLC 500 CBLAB003 RJ45 RLC RJ45 A B Name SOFTWARE UNIT OPERATION CRIMSON SOFTWARE Crimson software is available as a free download from Red Lion s website or it can be purchased on a CD see Ordering Information for part number The latest version of the software is always available from the website and updating your copy is free DISPLAY This operator interface uses a liquid crystal display LCD for displaying text and graphics The display utilizes a white LED for lighting the display The LEDs can be dimmed for low light conditions These LEDs have a limited lifetime Backlight lifetime is based upon the amount of time the display is turned on at full intensity Turning the backlight off when the display is not in use can extend the lifetime of your backlight This can be accomplished through the C
3. Read Power Supply Requirements in the section Installing and Powering the G306 for additional power supply information 2 BATTERY Lithium coin cell Typical lifetime of 10 years 3 LCD DISPLAY size 57inch TYPE FSTN COLORS PIXELS 320 X 240 BRIGHTNESS 165 cd m BACKLIGHT 20 000 HR TYP Lifetime at room temperature Refer to Display in Software Unit Operation 4 5 KEY KEYPAD for on screen menus 5 TOUCHSCREEN Resistive analog 6 MEMORY On Board User Memory 4 Mbyte of non volatile Flash memory Memory Card CompactFlash Type II slot for Type I and Type II CompactFlash cards 7 COMMUNICATIONS USB Port Adheres to USB specification 1 1 Device only using Type B connection WARNING DO NOT CONNECT OR DISCONNECT CABLES WHILE N POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS FOR SYSTEM SET UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION Serial Ports Format and Baud Rates for each port are individually software programmable up to 115 200 baud PGM Port RS232 port via RJ12 COMMS Ports RS422 485 port via RJ45 and RS232 port via RJ12 These two ports share the same hardware the G303 multiplexes the ports to communicate via two protocols These ports may be used to configure different master protocols but only one port may be used if configuring a slave protocol or AB DH485 DIMENSIONS In inches mm 2 30 58 4 a K 8 83 224
4. by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those expressly contained herein The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations Red Lion Controls Red Lion Controls Red Lion Controls Headquarters Europe 20 Willow Springs Circle Softwareweg 9 York PA 17406 NL 3821 BN Amersfoort Tel 1 717 767 6511 Tel 31 0 334 723 225 Fax 1 717 764 0839 Fax 31 0 334 893 793 Red Lion Controls India 201 B 2nd Floor Park Centra Opp 32 Mile Stone Sector 30 Gurgaon 122002 Haryana India Tel 91 984 487 0503 China Unit 302 XinAn Plaza Building 13 No 99 Tianzhou Road ShangHai P R China 200223 Tel 86 21 6113 3688 Fax 86 21 6113 3683
5. voltage to operate the backlight Touching the inverter board may result in injury to personnel CAUTION The circuit board contains static sensitive components Before handling the operator interface without the rear cover attached discharge static charges from your body by touching a grounded bare metal object Ideally handle the operator interface at a static controlled clean workstation Also do not touch the surface areas of the circuit board Dirt oil or other contaminants may adversely affect circuit operation To change the battery of a G306 remove power cabling and then the rear cover of the unit To remove the cover remove the four screws designated by the arrows on the rear of the unit Then by lifting the top side hinge the cover thus providing clearance for the connectors on the bottom side of the PCB as shown in the illustration below Install in the reverse manner Remove the old battery from the holder and replace with the new battery Replace the rear cover cables and re apply power Using Crimson or the unit s keypad enter the correct time and date Please note that the old battery must be disposed of in a manner that complies with your local waste regulations Also the battery must not be disposed of in fire or in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the G306 is a lithium type CR2025 BATTERY OPTIONAL FEATURES AND ACCES
6. with pin outs is available from Red Lion s website New cables and drivers are added on a regular basis If making your own cable refer to the G306 Port Pin Outs for wiring information ETHERNET COMMUNICATIONS Ethernet communications can be established at either 10 BASE T or 100 BASE TX The G306 unit s RJ45 jack is wired as a NIC Network Interface Card For example when wiring to a hub or switch use a straight through cable but when connecting to another NIC use a crossover cable The Ethernet connector contains two LEDs A yellow LED in the upper right and a bi color green amber LED in the upper left The LEDs represent the following statuses YELLOW solid Link established YELLOW flashing Data being transferred GREEN 10 BASE T Communications AMBER 100 BASE TX Communications On the rear of each unit is a unique 12 digit MAC address and a block for marking the unit with an IP address Refer to the Crimson manual and Red Lion s website for additional information on Ethernet communications G306 PORT PIN OUTS ETHERNET NIC COMMON 2 24V 420 1 RS232 PGM PORT RS232 PORTS The G306 has two RS232 ports There is the PGM port and the COMMS port Although only one of these ports can be used for programming both ports can be used for communications with a PLC The RS232 ports can be used for either master or slave protocols with any G306 configurati
7. 000 G3FILM_ Protective Films G3FILM06 Contact your Red Lion distributor or visit our website for complete selection 2 Use this part number to purchase Crimson software on CD with a printed manual USB cable and RS 232 cable Otherwise download for free from www redlion net 3 Antenna G3QANTO0 is NOT included with the card Must be purchased separately if needed 4 Red Lion offers RJ modular jack adapters Refer to the DR literature for complete details 5 Battery type is lithium coin type CR2025 6 Industrial grade two million write cycles SMART Modular Technologies model SG9CF UL Listed Directory Category NWGQ SPECIFICATIONS 1 POWER REQUIREMENTS Must use a Class 2 circuit according to National Electrical Code NEC NFPA 70 or Canadian Electrical Code CEC Part I C22 1 or a Limited Power Supply LPS according to IEC 60950 1 or Limited energy circuit according to IEC 61010 1 Power connection via removable three position terminal block Notes 1 Typical power with 24 VDC RS232 485 communications Ethernet communications CompactFlash card installed and display at full brightness 2 Maximum power indicates the most power that can be drawn from the G306 Refer to Power Supply Requirements under Installing and Powering the G306 3 The G3065 circuit common is not connected to the enclosure of the unit See Connecting to Earth Ground in the section Installing and Powering the G306 4
8. 3 DH485 TXEN Transmit enable open collector Voy 15 VDC Vor 0 5 V 25 mA max Note For additional information on the communications or signal common and connections to earth ground please see the Connecting to Earth Ground in the section Installing and Powering the G306 Ethernet Port 10 BASE T 100 BASE TX RJ45 jack is wired as a NIC Network Interface Card Isolation from Ethernet network to G3 operator interface 1500 Vrms 8 ENVIRONMENTAL CONDITIONS Operating Temperature Range 0 to 50 C Storage Temperature Range 20 to 70 C Operating and Storage Humidity 80 maximum relative humidity non condensing from 0 to 50 C Vibration to IEC 68 2 6 Operational 5 to 500 Hz 3 g Shock to IEC 68 2 27 Operational 35 g Altitude Up to 2000 meters 9 CERTIFICATIONS AND COMPLIANCES CE Approved EN 61326 1 Immunity to Industrial Locations Emission CISPR 11 Class A IEC EN 61010 1 RoHS Compliant UL Listed File E179259 UL Hazardous File E245515 Type 4X Indoor Enclosure rating Face only IP65 Enclosure rating Face only for G306Mxxx IP66 Enclosure rating Face only for G306MSxx IP20 Enclosure rating Rear of unit 10 CONNECTIONS Compression cage clamp terminal block Wire Gage 12 30 AWG copper wire Torque 5 7 inch pounds 56 79 N cm 11 CONSTRUCTION Steel rear metal enclosure with NEMA and IP rated aluminum front plate when correctl
9. 6 can be read by a card reader attached to a PC This information is stored in IBM Windows PC compatible FAT16 file format NOTE For reliable operation of this and other Red Lion products one of the following brands of CompactFlash card must be used SMART Modular Silicon Systems SimpleTech SanDisk Not all of the above manufacturers offer CompactFlash cards recognized to UL standards which may be required for your application Although RLC products limit use of CompactFlash card memory to 2 GB cards with a larger capacity can be used They MUST be formatted to 2 GB and use the FAT 16 file system It is recommended to format the CF card using the format utility from within Crimson LIMITED WARRANTY The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment provided the products have been stored handled installed and used under proper conditions The Company s liability under this limited warranty shall extend only to the repair or replacement of a defective product at The Company s option The Company disclaims all liability for any affirmation promise or representation with respect to the products The customer agrees to hold Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured
10. IGNITABLE CONCENTRATIONS INSTALLING AN OPTION CARD WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED AND THE AREA IS KNOWN TO BE NON HAZARDOUS Each option card comes with a cable for communications and three screws for ataching the option card to the G306 s rear cover To install the option card remove all power and I O communications cables from the unit Use the three screws provided to mount the option card to the rear cover of the G306 as shown in Figure 1 Figure 1 Connect the cable from the option card to CN11 on the main board of the G306 as shown in Figure 2 Be sure both ends of the cable are firmly seated into their appropriate connector housing Carefully replace the rear cover by reversing the instructions for removing the rear cover Figure 2 COMMUNICATING WITH THE G306 CONFIGURING A G306 The G306 is configured using Crimson software Crimson is available as a free download from Red Lion s website or it can be purchased on CD Updates to Crimson for new features and drivers are posted on the website as they become available By configuring the G306 using the latest version of Crimson you are assured that your unit has the most up to date feature set Crimson software can configure the G306 through the RS232 PGM port USB port or CompactFlash The USB port is connected using a standard USB cable with a Type B connector The driver needed to use the
11. MBYTE FLASH COMPACTFLASH SOCKET TO INCREASE MEMORY CAPACITY 5 7 INCH FSTN MONOCHROME QVGA 320 X 240 PIXEL LCD WITH WHITE LED BACKLIGHT OUTDOOR UNIT WITH UV RATED DISPLAY AVAILABLE 5 BUTTON KEYPAD FOR ON SCREEN MENUS THREE FRONT PANEL LED INDICATORS POWER UNIT FROM 24 VDC 20 SUPPLY OR 10 16 VDC SUPPLY RESISTIVE ANALOG TOUCHSCREEN CONTENTS OF PACKAGE G306M Operator Interface Panel gasket Template for panel cutout Hardware packet for mounting unit into panel Terminal block for connecting power ORDERING INFORMATION Operator Interface for indoor applications 24 VDC G306M000 only textured finish with embossed keys 12 VDC Operator Interface for indoor or outdoor 24 VDC G306M010 G306MS00 applications glossy finish with UV rated overlay keys are not embossed 12 VDC G306MS10 CompactFlash Card G3CF 3CFXxxx G3RS _ RS232 485 Optional Communication Card G3RS0000 G3CN _ _ CANopen Optional Communication Card G3CNO0000 DeviceNet option card for G3 operator interfaces G3DN pane with isolated high speed communications ports G3DNO0000 G3PBDP Profibus DP Optional Communication Card G3PBDP00 G3GSM GSMIGPRS Modem Option Card for G3 operator G3GSM000 interface PSDR _ DIN Rail Power Supply PSDRxxxx SFCRM2 Crimson 2 0 2 SFCRM200 RS 232 Programming Cable CBLPROGO CBL USB Cable Communications Cables 1 CBLUSBOO DR DIN Rail Mountable Adapter Products 4 Replacement Battery 5 BNL20
12. RTH GROUND The protective conductor terminal is bonded to conductive A N parts of the equipment for safety purposes and must be connected to an external protective earthing system Each G306 has a chassis ground terminal on the back of the unit Your unit should be connected to earth ground protective earth The chassis ground is not connected to signal common of the unit Maintaining isolation between earth ground and signal common is not required to operate your unit But other equipment connected to this unit may require isolation between signal common and earth ground To maintain isolation between signal common and earth ground care must be taken when connections are made to the unit For example a power supply with isolation between its signal common and earth ground must be used Also plugging in a USB cable may connect signal common and earth ground 1 USB s shield may be connected to earth ground at the host USB s shield in turn may also be connected to signal common POWER SUPPLY REQUIREMENTS The 24 V G306M G306M000 amp G306MS00 require a 24 VDC power supply rated at 7 5 W The 12 V G306M G306M010 amp G306MS10 require a 10 to 16 VDC power supply rated at 8 5 W Your unit may draw considerably less than the maximum rated power depending upon the options being used As additional features are used your unit will draw increasing amounts of power Items that could cause increases in current are additional communica
13. SORIES OPTIONAL COMMUNICATION CARD Red Lion offers optional communication cards for fieldbus communications These communication cards will allow your G306 to communicate with many of the popular fieldbus protocols Note that communications cards which require their own 24VDC connection for example the G3GSM must not be used with the 12 VDC versions of the G306 G306M010 amp G306MS10 Red Lion is also offering a communications card for additional RS232 and COMPACTFLASH SOCKET CompactFlash socket is a Type II socket that can accept either Type I or II cards Use cards with a minimum of 4 Mbytes and formatted to a maximum of 2 Gbytes See Note box below with the G306 s CompactFlash socket Cards are available at most computer and office supply retailers CompactFlash can be used for configuration transfers larger configurations data logging and trending RS422 485 communications Visit Red Lion s website for information and availability of these cards CUSTOM LOGO Each G3 operator interface has an embossed area containing the Red Lion logo Red Lion can provide custom logos to apply to this area Contact your distributor for additional information and pricing i T i 51 13 f j 65 42 x FRONT OVERLAY l Note Do not remove or insert the CompactFlash card while power is applied Refer to Front Panel LEDs CompactFlash Insert Face Up Information stored on a CompactFlash card by a G30
14. USB port will be installed with Crimson The RS232 PGM port uses a programming cable made by Red Lion to connect to the DB9 COM port of your computer If you choose to make your own cable use the G306 Port Pin Out Diagram for wiring information The CompactFlash can be used to program a G3 by placing a configuration file and firmware on the CompactFlash card The card is then inserted into the target G3 and powered Refer to the Crimson literature for more information on the proper names and locations of the files USB DATA TRANSFERS FROM THE COMPACTFLASH CARD WARNING DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS FOR SYSTEM SET UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION In order to transfer data from the CompactFlash card via the USB port a driver must be installed on your computer This driver is installed with Crimson and is located in the folder C Program Files Red Lion Controls Crimson 2 0 Device after Crimson is installed This may have already been accomplished if your G306 was configured using the USB port Once the driver has been installed connect the G306 to your PC with a USB cable and follow Mounting the CompactFlash instructions in the Crimson 2 user manual CABLES AND DRIVERS Red Lion has a wide range of cables and drivers for use with many different communication types A list of these drivers and cables along
15. on Examples of RS232 communications could involve another Red Lion product or a PC By using a cable with RJ12 ends on it and a twist in the cable RS232 communications with another G3 product or the Modular Controller can be established Red Lion part numbers for cables with a twist in them are CBLPROGO CBLRLCO1 or CBLRC02 3 G3 RS232 to a PC G3 RJ12 Name PC DB9 ICM5 CONNECTING A G306 OPERATOR INTERFACE TO AN ICM5 a e a ami OG i OOOO vyvv CBLPROGO j ICM5 DIP Switch Settings _ _ ON a keene fans x x ON TNO THOR MORO nmTHOR Q0000ZoyyZz veouwwwwy 32322232545 gezZzEEO0 ao a on oo0aa ao00 a gs ZZ 2222 essoaoGPFanF OO 665656 S8g lt 3sssga 2zz25 AN Dnr a 8SSsRRBS G5 AA Dpp Fabet F Fe OQ gop w u qaqaqa fq 55 FEEL Z2 6666 iai Lat 1 x Application Dependent E oe L 1 CBLPROGO can also be used to communicate with either a PC or an ICM5 2 DB9 adapter not included 1 foot long 3 DB9 adapter not included 10 feet long Examples of RS485 2 Wire Connections G3 to Red Lion RJ11 CBLRLCO00 DLC IAMS ITMS PAXCDC4C G3 to Modular Controller CBLRLC05 Modular Controller 1 4 4 1 RS422 485 COMMS PORT The G306 has one RS422 485 port This port can be configured to act as either RS422 or RS485 RS422 485 4 WIRE
16. re Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion net lpn Bulletin No G306MH E Drawing No LP0843 Released 05 14 MODEL G306M GRAPHIC MONOCHROME LCD OPERATOR INTERFACE TERMINAL WITH QVGA DISPLAY AND TOUCHSCREEN CONFIGURED USING CRIMSON SOFTWARE VERSION 2 0 UPTO 5 RS 232 422 485 COMMUNICATIONS PORTS PV 100 PV 125 SV 100 SV1 125 ZNA i alv CE FOR USE IN HAZARDOUS LOCATIONS Class I Division 2 Groups A B C and D C US LISTED 43NH PROCESS CONTROL EQUIPMENT GENERAL DESCRIPTION The G306M Operator Interface Terminal combines unique capabilities normally expected from high end units with a very affordable price It is built around a high performance core with integrated functionality The G306 is able to communicate with many different types of hardware using high speed RS232 422 485 communications ports and Ethernet 10 Base T 100 Base TX communications In addition the G306 features USB for fast downloads of configuration files and access to trending and data logging A CompactFlash socket is provided so that Flash cards can be used to collect your trending and data logging information as well as to store larger configuration files In addition to accessing and controlling of external resources the G306 allows a user to easily view and enter information The unit uses a Liquid Crystal Display LCD module which is easily readable in both indoor and outdoor applications Users can enter da
17. rimson software when configuring your unit FRONT PANEL LEDS There are three front panel LEDs Shown below is the default status of the LEDs INDICATION RED TOP LABELED PWR FLASHING Unit is in the boot loader no valid configuration is loaded 1 STEADY Unit is powered and running an application YELLOW MIDDLE OFF No CompactFlash card is present STEADY FLASHING RAPIDLY Valid CompactFlash card present CompactFlash card being checked Unit is writing to the CompactFlash either because it is FLICKERING storing data or because the PC connected via the USB port has locked the drive 2 FLASHING SLOWLY GREEN BOTTOM FLASHING A tag is in an alarm state Incorrectly formatted CompactFlash card present STEADY Valid configuration is loaded and there are no alarms present 1 The operator interface is shipped without a configuration After downloading a configuration if the light remains in the flashing state continuously try cycling power If the LED still continues to flash try downloading a configuration again 2 Do not turn off power to the unit while this light is flickering The unit writes data in two minute intervals Later Microsoft operating systems will not lock the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the Crimson 2 User Manual
18. ta through the touchscreen and or front panel 5 button keypad SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use the controller to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the controller AS A The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS DIVISION 2 CAUTION Risk of electric shock A CAUTION Risk Of Danger Read complete instructions prior to installation and operation of the unit CompactFlash is a registered trademark of CompactFlash Association 2 RS 232 AND 1 RS 422 485 ON BOARD 1 RS 232 AND 1 RS422 485 ON OPTIONAL COMMUNICATIONS CARD 10 BASE T 100 BASE TX ETHERNET PORT TO NETWORK UNITS AND HOST WEB PAGES USB PORT TO DOWNLOAD THE UNIT S CONFIGURATION FROM A PC OR FOR DATA TRANSFERS TO A PC UNIT S CONFIGURATION IS STORED IN NON VOLATILE MEMORY 4
19. tions optional communications card CompactFlash card and other features programmed through Crimson In any case it is very important that the power supply is mounted correctly if the unit is to operate reliably Please take care to observe the following points The power supply must be mounted close to the unit with usually not more than 6 feet 1 8 m of cable between the supply and the operator interface Ideally the shortest length possible should be used The wire used to connect the operator interface s power supply should be at least 22 gage wire If a longer cable run is used a heavier gage wire should be used The routing of the cable should be kept away from large contactors inverters and other devices which may generate significant electrical noise A power supply with an NEC Class 2 or Limited Power Source LPS and SELV rating is to be used This type of power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults SELV is an acronym for safety extra low voltage Safety extra low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF
20. y fitted with the gasket provided Installation Category I Pollution Degree 2 12 MOUNTING REQUIREMENTS Maximum panel thickness is 0 25 6 3 mm For NEMA 4X IP66 sealing a steel panel with a minimum thickness of 0 125 3 17 mm is recommended Maximum Mounting Stud Torque 17 inch pounds 1 92 N m 13 WEIGHT 3 0 lbs 1 36 Kg 7 42 188 5 INSTALLING AND POWERING THE G306 MOUNTING INSTRUCTIONS This operator interface is designed for through panel mounting A panel cut out diagram and a template are provided Care should be taken to remove any loose material from the mounting cut out to prevent that material from falling into the operator interface during installation A gasket is provided to enable sealing to NEMA 4X IP66 specification Install the ten kep nuts provided and tighten evenly for uniform gasket compression Note Tightening the kep nuts beyond a maximum of 17 inch pounds 1 92 N m may cause damage to the front panel 8 25 209 6 10X 188 4 8 H 7 63 193 8 a 1 T i 2 75 69 9 M 5 88 6 50 H 149 4 165 1 All tolerances 0 010 0 25 mm ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING DIVISION 2 WIRING METHODS AS SPECIFIED IN THE NATIONAL ELECTRICAL CODE NFPA 70 FOR INSTALLATION WITHIN THE UNITED STATES OR AS SPECIFIED IN THE CANADIAN ELECTRICAL CODE FOR INSTALLATION IN CANADA CONNECTING TO EA