1. 2 5 A reversible 15 50 C IP30 13 Cleaning and maintenance Powerturn 14 GEZE Powerturn Cleaning and maintenance GEZE 15 Germany GEZE Sonderkonstruktionen GmbH Planken 1 97944 Boxberg Schweigern Tel 49 0 7930 9294 0 Fax 49 0 7930 9294 10 E Mail sk de geze com GEZE GmbH Niederlassung S d West Tel 49 0 7152 203 594 E Mail leonberg de geze com GEZE GmbH Niederlassung S d Ost Tel 49 0 7152 203 6440 E Mail muenchen de geze com GEZE GmbH Niederlassung Ost Tel 49 0 7152 203 6840 E Mail berlin de geze com GEZE GmbH Niederlassung Mitte Luxemburg Tel 49 0 7152 203 6888 E Mail frankfurt de geze com GEZE GmbH Niederlassung West Tel 49 0 7152 203 6770 E Mail duesseldorf de geze com GEZE GmbH Niederlassung Nord Tel 49 0 7152 203 6600 E Mail hamburg de geze com GEZE Service GmbH Tel 49 0 1802 923392 E Mail service info de geze com GEZE GmbH Reinhold V ster Stra e 21 29 71229 Leonberg Germany Austria GEZE Austria E Mail austria at geze com www geze at Baltic States GEZE GmbH Baltic States office E Mail office latvia geze com www geze com Benelux GEZE Benelux BV E Mail benelux nl geze com www geze be www geze nl Bulgaria GEZE Bulgaria Trade E Mail office bulgaria geze com www geze bg China GEZE Industries Tianjin Co Ltd E Mail chinasales geze com cn www geze com cn GEZE Industries
2. Original operating instructions Powerturn miei Valid for variants Powerturn 1 leaf 2 leaf Powerturn F 1 leaf Powerturn F IS 2 leaf Powerturn F R 1 leaf 2 leaf 156539 01 Powerturn Table of Contents Symbolsand ee 3 Pr EE 3 Kl 3 1 General safety e 4 1 1 RE A 2 DD QS CII TION agereechte ENEE Eeer 6 2 1 Types of installation and Mr E EE 6 2 2 GOI POSIEION AA WAA WAA AA A WAA AA KC AA 6 3 Operat rio n absscbesascasadatdunniavsosais seta E AE aa 7 3 1 JA BT Ka LL EE 7 3 2 Normal ii an ERNE E ee E 7 3 3 Operating modesikey ama isplay css ccvssssscssssecsisvscsssccisssessossssensecsossscalavenstaassestuaseunssconcusiiaasuarnanstacandiacsassetadesceeistssbasstendesessseccesnsueanabesstasete 8 3 4 Mechanical programme switch MPS optional 9 3 5 Display programme switch optional 10 4 TroubleshootiNg animale Earra pisaa raoa Ea Era TEE i 11 5 Cleaning and Kane 12 5 1 lee 12 5 2 GENIE 12 5 3 Testing by a COMPSTENE EXPEL scssisiscsssscsssecenssescsaresssneszastessosnsoesnntyosscscuetonscesausvatasnissnssscanssesdnsgaceavergnstsschausedenssaestaascenssedansybeloucteconseecandtats 12 6 EG Aa ata Ka aa EE 13 Powerturn Symbols and illustrations Warning notices Warning notices are used in these instructions to warn you of property damage and personal injury gt Always read and observe these warning notices gt Follow all measures that are labelled with the warning symbol and warning word Warning Warni
3. by GEZE must be observed The commissioning prescribed installation maintenance and repair work must be performed by properly trained personnel authorised by GEZE GEZE shall assume no liability for damage caused by unauthorised changes to the system The owner is responsible for safe operation of the system If safety equipment is misaligned thus preventing it from fulfilling its intended purpose further operation is not permissible The service technician must be informed without delay GEZE makes no guarantee for combinations with third party products Furthermore only original GEZE parts may be used for repair and maintenance work The connection to the power supply must be made by a professional electrician The main connection and protective conductor test must be performed according to DIN VDE 0100 610 Use a customer accessible 16 A overload cut out that disconnects the system from the power supply as the line side disconnecting device Attach safety stickers to glass door leaves Protect the programme switch against unauthorised access In compliance with Machinery Directive 2006 42 EC a risk analysis must be performed and the door system identified in accordance with CE Marking Directive 93 68 EEC before the door system is commissioned Observe the current status of directives standards and country specific regulations especially 2 ASR A1 7 Directives for doors and gates a DIN 18650 Building hardware Powered pedes
4. by means of the mechanical elements of the door closing sequence selector so that it can also close completely Electrical door opener Open circuit door opener Available as AC or DC door opener version When the door drive is actuated the door opener is activated by the control unit of the door drive provided the door is in the closed position The door opener remains activated until the door has left the closed position Static current DC door opener version The door opener is switched off when the door drive is acti vated provided the door is in the closed position The door opener remains switched off until the door has left the closed position Lock feedback The lock feedback function is a contact integrated in the door catch that is activated when the door is locked mechanically by the tie bolt of the door lock It signals to the control unit that the door is locked mechanically and can therefore not be opened by the door drive In this case the control unit ignores the control commands of all the contactors Reset Button for restarting the drive after the operating voltage has been switched on or after a fire alarm has been terminated When the button is pressed the self retention integrated in the drive is activated causing the drive to be activated Latching function When the door is closed in a de energised state the door leaf is impeded by the lock latch of the door opener To make sure the door can pass
5. modes display flashes yellow for 3 s the setting has been accepted Then the operating modes display is off a When the operating modes push button 21 is actuated again the operating modes display 21 flashes for 3 s in red operation is not accepted Changing the mode of operation fixed leaves The drive on the fixed leaf is switched on and off using the on off switch When the drive is switched on the operating modes display 21 lights up in the colour of the mode of operation see below If the drive is switched off the operating modes display 21 does not light up Operating mode Colour of the operating modes display 21 OFF off NA night red LS shop closing white AU automatic green DO permanently open blue Powerturn Operation Mechanical programme switch MPS optional a Additionally it can be connected to the internal operating modes key At the mechanical programme switch the system operating mode is selected and the corresponding programme is displayed The mechanical programme switch is accessible for everyone without a key operated switch The mechanical programme switch MPS ST must be used for disa bling The desired operating mode is selected by using the rotary switch Mechanical programme switch MPS At the mechanical programme switch MPS ST the system operating mode is selected and the corresponding programme is displayed Operation of the mechanica
6. Tianjin Co Ltd Branch Office Shanghai E Mail chinasales geze com cn www geze com cn GEZE Industries Tianjin Co Ltd Branch Office Guangzhou E Mail chinasales geze com cn www geze com cn GEZE Industries Tianjin Co Ltd Branch Office Beijing E Mail chinasales geze com cn www geze com cn France GEZE France S A R L E Mail france fr geze com www geze fr Tel 0049 7152 203 0 Fax 0049 7152 203 310 www geze com Hungary GEZE Hungary Kft E Mail office hungary geze com www geze hu Iberia GEZE Iberia S R L E Mail info geze es www geze es India GEZE India Private Ltd E Mail office india geze com www geze in Italy GEZE Italia S r l E Mail italia it geze com www geze it GEZE Engineering Roma S r l E Mail roma geze biz www geze it Poland GEZE Polska Sp z 0 0 E Mail geze pl geze com www geze pl Romania GEZE Romania S R L E Mail office romania geze com www geze ro Russia OOO GEZE RUS E Mail office russia geze com www geze ru Scandinavia Sweden GEZE Scandinavia AB E Mail sverige se geze com www geze se Scandinavia Norway GEZE Scandinavia AB avd Norge E Mail norge se geze com www geze no Scandinavia Denmark GEZE Danmark E Mail danmark se geze com www geze dk Singapore GEZE Asia Pacific Pte Ltd E Mail gezesea geze com sg www geze com South Africa GEZE Distributors Pty Ltd E Mail info gezesa co za Www geze co za Swi
7. ead off the number of the fault message note it down and notify the service technician Powerturn Troubleshooting 4 Troubleshooting Problem Cause Remedy Door only opens and closes Obstruction in sliding path gt Remove obstruction and check door leaf slowly for ease of movement Safety sensor close SIS soiled gt Clean the safety sensor close Safety sensor close SIS misaligned or gt Notify a service technician defective Door opens and closes Obstruction in sliding path gt Clear the obstruction constantly Light beams or reflections e g reflective gt Check detection field of movement detec floor falling rain tor Misaligned movement detector gt Check detection field of movement detec tor Door only opensa crack Obstruction in sliding path gt Remove obstruction and check door leaf for ease of movement Door does not open Obstruction in sliding path gt Remove obstruction and check door leaf for ease of movement Movement detector misaligned or defective outside gt Check the movement detector If neces sary notify a service technician Emergency stop actuated gt Unlock emergency stop Night operating mode gt Select a different operating mode Shop closing time operating mode gt Select Automatic operating mode Door locked mechanically gt Unlock the door Door opener does not release gt Noti
8. ervice technician Filthy U e j GEZE offers maintenance contracts with the following services 2 Inspection of fastening elements for firm fit 2 Performance of miscellaneous adjustment work a Performance of operational checks a Checking all the safety and control equipment of the door system o Lubrication of all the moveable parts Testing by a competent expert In accordance with the Guidelines for windows doors and gates ASR A1 7 and GUV 16 10 Section 6 power operated doors must be inspected for safety by a trained professional before initial commissioning and at least once a year GEZE offers the following services Inspection and operational checks of all safety and control equipment in accordance with the requirements in the test log for power operated windows doors and gates Sliding doors and sliding gates ZH 1 580 2 edition Powerturn Technical data Technical data Opening time Closing time Mains voltage Frequency Protection rating Nominal capacity Mains connection Primary fuse Secondary fuse Secondary voltage transformer Control voltage for external compo nents Output current control voltage 24 V Fuse protection lt 24V Temperature Range IP rating KSE 5 255 230 V AC 10 Yo 50 Hz 200 W Fixed connection installation cable or cable transition 10 A slow blow 5x20 mm 33 V AC 46 V DC 24V DC 5 Yo 1200 mA permanently 1800 mA briefly 2 s duty ratio 30
9. fy a service technician Fire alarm active only Powerturn F gt Press the Reset button Drive defective gt Notify a service technician Door does not close Safety sensor close SIS soiled gt Clean the safety sensor close SIS Safety sensor close SIS misaligned or gt Notify a service technician defective Obstruction in sliding path gt Remove obstruction and check door leaf for ease of movement Movement detector triggers constantly gt Check the movement detector If neces sary notify a service technician Permanently open operating mode gt Select a different operating mode Current impulse button function controls Terminate controlling by pressing the but ton again Display programme switch Display programme switch is disabled gt Actuate key operated switch for release cannot be operated Display programme switch defective gt Notify a service technician Display programme switch Connection between display programme gt Notify a service technician displays DD switch and control unit faulty Display programme switch or control unit gt Notify a service technician defective Display programme switch Power failure gt Check mains fuse is dark Connection between display programme gt Notify a service technician switch and control unit faulty Display programme switch or control unit gt Notify a service technician defective Display of fault messages Fault in the door system gt Note fault messages Up to 10 different on the disp
10. he end of the hold open time door closes Safety sensor open SIO is triggered when the door is closed Door remains closed A person moves toward the opened door and a movement detector is activated Door remains open A person moves toward the closing door and a movement detector is activated Door reopens immediately Door contacts an obstruction when opening Door stops waits and attempts again to move to the open position at a reduced speed Then the door closes again Door contacts an obstruction when closing Door reopens immediately waits the hold open time and then closes at a reduced speed Additional door functions Which switch button What does the switch button do Emergency stop switch The door stops immediately in every operating mode and holds the position until the emergency stop switch is unlocked Key operated switch of the display programme switch If a key operated switch is connected to the display pro gramme switch the operation of the display programme switch can be locked or released with it Contactor authorised KB e g outside key operated switch Door opens once and closes after the hold open time The set operating mode is retained Operation Powerturn 3 3 Operating modes key and display Changing the operating mode with single leaf doors or active leaves gt Press the operating modes key 21 briefly The operating m
11. l programme switch MPS ST is only pos sible with the supplied key Disabling the mechanical programme switch MPS ST gt Remove the key The desired operating mode is selected by using the key operated rotary switch Mechanical programme switch MPS ST with integrated key operated switch MPS MPS ST Operating condition Explanatory notes Automatic Door opens and closes again The inside and outside contactors are active a Opening of 2 leaves At 2 leaf systems gt Switch to opening of 2 leaves in all operating modes With MPS MPS ST lt gt gt 7 a Opening of 1 leaf With MPS MPS ST gt gt Select the opening of 2 leaves at the corresponding position Switch to opening of 1 leaf in all operating modes gt Select the opening of 1 leaf at the corresponding position Shop closing Door only opens and closes if someone exits DI Permanently open Door remains open ad gt Night Le Door opens and closes only when actuated using the key operated switch Fixed leaf On Off Door is enabled and can be moved by hand 11 1 Operation Powerturn 3 5 10 Display programme switch optional a Additionally it can be connected to the internal operating modes key If a dot appears in the bottom right hand part of the display D maintenance is due gt Notify a service technician YA Fuj If a dot ap
12. lay programme fault messages can occur in succession switch The display changes about every 10 seconds gt Notify a service technician 11 Cleaning and maintenance Powerturn 5 A 5 1 5 2 5 3 12 Cleaning and maintenance CAUTION Danger of injury due to impact and crushing gt Disconnect the drive from the 230 V mains network before carrying out cleaning work gt Secure door leaves against accidental movement before carrying out cleaning work gt Installation maintenance and repair work must be performed by properly trained personnel authorised by GEZE Cleaning What is to be cleaned How is it to be cleaned Safety sensor close SIS e g light sensors Wipe with damp cloth Glass surfaces Wipe with a cold vinegar water mixture then dry Stainless surfaces Wipe with soft cloth Painted surfaces Wipe with water and soap Anodised surfaces Wipe with non alkaline potassium soap pH value 5 5 7 Display programme switch Wipe with soft cloth Do not use a cleaning agent viv v viv v Service The owner must ensure that the system functions properly To guarantee perfect operation the door system must be serviced regularly by a service technician Maintenance must be carried out at least once a year or according to the maintenance display on the display programme switch If a dot appears in the bottom right hand part of the display maintenance is due far gt Notify a s
13. n safety sensor OSS optional Door adapter cable optional Reset push button Bushing for service adapter ST 220 Operating modes key and display Powerturn Operation Operation Functions The set parameters of the drive functions may only be modified by properly trained persons The commissioning and setting or changing of door parameters and some special drive functions can be done using the display programme switch ST 220 or GEZEconnects Querying and modifying of the set drive parameters are described in the circuit diagram Normal operation In certain cases e g with special wiring special function settings parameters special software deviations from the information given in this manual can occur If this is the case please ask the service technician responsible In normal door operation the door is automatically opened and closed What happens What does the door do A contactor button switch or movement detector is triggered Door opens waits the hold open time and then closes Safety sensor close SIS is triggered when the door is open e g light switch Door remains open Safety sensor close SIS is triggered while the door is clos ing The door immediately opens again depending on the parameter adjustment Safety sensor open SIO is triggered while door is opening The door stops and remains in the position until the end of actuation door opens or until t
14. ng word Meaning symbol CAUTION Danger to persons a ar Non observance can result in minor injuries More symbols and illustrations In order to illustrate proper operation important information and technical information is highlighted Symbol Meaning means Important Information Q information to prevent property damage to understand or optimise the operation sequences means Additional Information Symbol for an action There is something you must do here gt Observe the order of multiple operational steps Product liability According to a manufacturer s liability for his products as defined under product liability law the information contained in this brochure product information and proper usage misuse product performance product main tenance information and instructional obligations must be observed Non observance releases the manufac turer from his liability Special cases In certain cases such as with a Special wiring a special function settings parameters a Special software deviations from the information given in this user manual may occur gt If this is the case please ask the service technician responsible General safety precautions Powerturn 1 1 General safety precautions D Carefully read and abide by this user manual before commissioning the door In addition always observe the following safety precautions Operating maintenance and repair conditions specified
15. odes display immediately switches one mode of operation further The drive itself does not change the mode of operation to the new mode of operation until 1 s after the last key has been pressed Operating modes sequence gt OFF gt Night gt Shop closing gt Automatic gt Permanently open gt OFF gt Night gt Thanks to the 1 s delay it is possible to change the mode of operation from AU automatic through DO perma nently open to NA night without the door opening in the briefly actuated DO permanently open setting 2 In normal mode the operating modes display lights up in the colour of the current mode of operation a f the control has not been taught at this point the operating modes display lights up yellow light on perma nently a If the control has not been initialised yet the operating modes display lights up in the colour of the current mode of operation periodically interrupted by two short flashing impulses 1 Hz 2 f one or more faults are pending the operating modes display flashes quickly 10 Hz in the colour of the cur rent mode of operation 2 Inthe OFF mode of operation there is no fault display on the operating modes display a f the parameter switch off internal operating modes key AB is set the integrated operating modes switch 21 is disabled and the integrated operating modes display 21 is switched off a f the setting is changed from enabled to disabled or vice versa the operating
16. pears in the middle of the display the door has not D z0 yet been fully initialised after the mains voltage has been switched on Initialisation is carried out automatically when the drive opens and closes the door Operating mode Key Display T la EE e ch OFF A v Display programme switch Explanatory notes Automatic a Opening of 2 leaves a Opening of 1 leaf D vos gt lt gt JH JHE Door opens and closes again Inside and outside contactors active With 2 leaf Appendices Switch to opening of 2 leaves in all operating modes gt Select the opening of 2 leaves at the corresponding position With 1 leaf Appendices Switch to opening of 1 leaf in all operating modes gt Select the opening of 1 leaf at the corresponding position Shop closing Door only opens and closes if someone exits Only inner contactor active Permanently open Door remains open HGO Night Door opens and closes only when actuated using the key operated switch Door is enabled and can be moved by hand Setting the language The displayed language can be set in the service menu of the display programme switch Available languages German English French and Italian Fault messages on the display If a fault occurs in the door system it is displayed on the display programme switch about every 10 seconds gt R
17. the lock latch safely during closing an integrated limit switch is actuated in the drive once a specific opening an gle has been reached reducing the braking strength The door accelerates and closes into the lock at increased speed In an energised state this function is regulated by the drive control unit Description Powerturn 2 2 Description Types of installation and versions 2 The door drive unit can be mounted in transom mounting at the lintel or in door panel mounting on the door panel 2 The door drive is available as 1 leaf or 2 leaf version Composition The door system shown is only a schematic diagram For technical reasons we cannot show all of the possibilities here The operating elements can be arranged individually Example Door drive Powerturn 1 leaf transom installation Door drive unit Link arm or lever Smoke switch control unit 2 Outside contactor KA optional Contactor authorised KB optional Smoke switch 2 Contact sensor inside KI optional Display programme switch optional Key operated switch for enabling the display programme switch optional Emergency stop switch optional WO ONAN P DO 4 gt C3 2 optional in conjunction with Powerturn NM N COCOANAUNARWHN a Circuit breaker CLOSE DOOR 2 Electrical door opener optional Inside outside Door handle with door lock optional Safety sensor close SIS optional Ope
18. the room enclosed by the door Control function in the AUTOMATIC operating mode The contactor does not have any function in the SHOP CLOSING TIME and NIGHT OFF operating modes Contactor Access control function for example key operated switch or card reader used by authorised KB authorised persons to control the door drive The control function is active in the AUTOMATIC SHOP CLOSING TIME and NIGHT OFF operating modes Contactor with current impulse Button for opening and closing the door Control function only in the AUTOMATIC and function SHOP CLOSING TIME operating modes The door is opened automatically when the button is first pressed and closed again automatically when the button is pressed the second time The function can be activated during commissioning by setting param eters using the display programme switch ST 220 or GEZEconnects If the contactor is connected to the fixed leaf control system by means of the current impulse function both door leaves open when activated even when the fixed leaf control system is deactivated Powerturn General safety precautions Term Statement Push amp Go When the door is pressed manually out of the closing position with an activated Push amp Go function in the AUTOMATIC operating mode the door opens automatically as soon as a specific adjustable opening angle is exceeded Open safety sensor OSS Presence detector e g active infrared light sensor for protecting
19. the swinging range of the door in the opening direction As a rule the sensor is located on the hinge side of the door on the door leaf Safety sensor close SIS Presence detector e g active infrared light sensor for protecting the swinging range of the door in the closing direction As a rule the sensor is located on the opposite hinge side of the door leaf Emergency stop Self locking switch with which immediate stopping of the door drive can be triggered in case of danger The drive remains in its current position until the user releases the emergency stop switch again thus terminating the emergency stop situation Door closing sequence selec tor Electrical door closing sequence selector In normal operation of double leaf door drives the closing sequence of the door leaves is controlled by the control units of the door drives with the fixed leaf being closed first The active leaf remains in the open position until the fixed leaf has reached the closed position then the active leaf begins to close Integrated door closing sequence selector IS The closing sequence is controlled mechanically in the case of a power failure at dou ble leaf door systems with Powerturn F IS The door leaves are closed by means of the power storage of the drives with the moveable leaf being kept open by the integrated mechanical close sequence control unit When the fixed leaf has reached the closed position it releases the active leaf
20. trian doors 2 DIN VDE 0100 610 Erection of low voltage installations 2 DIN EN 60335 2 103 Safety of electrical devices for home use and similar purposes special requirements for drives for gates doors and windows a Accident prevention regulations especially BGV A1 General regulations and BGV A2 Electrical systems and equipment Terms Term Statement Hinge side The side of the door where the hinges from which the door leaf is suspended are located Usually that side of the door located in the opening direction Opposite hinge side The side of the door that lies opposite the hinge side Usually that side of the door located in the closing direction Active leaf The main leaf of a double leaf door The active leaf must open as the first door leaf and close as the last door leaf when the door is used Fixed leaf The secondary leaf of a double leaf door When the door is used the fixed leaf may not open until the active leaf has left the closing position and must close again as the first door leaf Inside contactor KI Button switch or movement detector for controlling the door drive The contactor is located within the room enclosed by the door Control function in the AUTOMATIC and SHOP CLOSING TIME operating modes The contactor does not have any function in the NIGHT OFF operating mode Outside contactor KA Button switch or movement detector for controlling the door drive The contactor is located outside
21. tzerland GEZE Schweiz AG E Mail schweiz ch geze com www geze ch Turkey GEZE Kap ve Pencere Sistemleri E Mail office turkey geze com www geze com Ukraine LLC GEZE Ukraine E Mail office ukraine geze com www geze ua United Arab Emirates GCC GEZE Middle East E Mail gezeme geze com www geze ae United Kingdom GEZE UK Ltd E Mail info uk geze com www geze com Der MaBstab DIN ISO 9001 unseres Handelns

Download Pdf Manuals

image

Related Search

Related Contents

Nikon SK-9 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file