Home

Sprinter 150/150M/250M User Manual

image

Contents

1. 8 3 Optical Collimation Reticle Ad justment o Step Description Lk Level instrument 2 Turn instrument by 180 3 Center bubble if it extends beyond the centering circle 4 Correct half of the error with the Allen key CS Repeat steps 1 to 4 until the circular level bubble is centered at any random telescope pointing Step Description 1 Turn Allen key until design value is reached 2 Check collimation If the collimation error exceeds 3 mm over 60 m distance the colli mation needs to be adjusted Check amp Adjust 17 O Sprinter 150 150M 250M 1 0 0en 9 Error Messages No Error message Counter measure causes E99 System Error Contact Hardware faults or file errors or adjustment errors or setting errors rendering instrument not working prop Services erly E100 Low Battery Change to new or freshly charged batteries E101 Point No Not Incre Change the POD Max PtID is 99999999 and do not end any 8 characters string with an alphabet char mented acter E102 Too Bright Darken staff or reduce lighting on staff or shade the objective telescope E103 Too Dark Light up staff uniformly E104 No Staff Check targeting E105 Invalid Entry Check the entry input E106 Out Of Level Level the instrument E107 Memory Full Set internal memory to OFF and continue m
2. Operation e a Sprinter 150 150M 250M 1 0 0en Step Key Screen Description 6 5 BF Line Levelling Measurement we A Initialize the BIF method Step Key Screen Description L bel A Initialize the BF method 2 O Initiate measurement to Benchmark 3 Backsight measurement displayed 4 menu Measure to the foresight staff lt 5 Foresight measurement displayed 6 O System refreshes a standby display for measurement to the backsight of next change point 2 O Initiate measurement to Benchmark 3 Backsight measurement displayed 4 menu To start Intermediate sight measurement go to menu set Intermediate Sight to ON or press Height amp Distance key 5 Intermediate sight measurement lt H displayed 6 menu Ge Go to menu set Intermediate Sight to OFF or press Height amp Distance key then measure to the foresight staff 7 Foresight measurement displayed 8 System refreshes a standby display for measurement to the backsight of next change point Operation oa Sprinter 150 150M 250M 1 0 0en 6 6 BFFB Line Levelling Measurement Step Key Screen Description Step Key Screen Description 1 Initialize the BFFB method 9 Backsight second sighting measure menu a Me Ge lt H ment displayed lt System displ t Ch
3. non standard cables or external batteries Safety Directions a Sprinter 150 150M 250M 1 0 0en Precautions Use only the eguipment and accessories recommended by Leica Geosystems When combined with the product they meet the strict requirements stipulated by the guidelines and standards When using computers and two way radios pay attention to the informa tion about electromagnetic compatibility provided by the manufac turer CAUTION Disturbances caused by electromagnetic radiation can result in erroneous measurements Although the product meets the strict regulations and standards which are in force in this respect Leica Geosystems cannot completely exclude the possibility that the product may be disturbed by very intense electromagnetic radiation for example near radio transmitters two way radios or diesel generators Precautions Check the plausibility of results obtained under these conditions WARNING If the product is operated with connecting cables attached at only one of their two ends for example external supply cables inter face cables the permitted level of electromagnetic radiation may be exceeded and the correct functioning of other products may be impaired Precautions While the product is in use connecting cables for example product to external battery product to computer must be connected at both ends 12 7 FCC Statement Applicable in U S WARNING This equipment has been tested and found t
4. or carry the tripod with its legs splayed across your shoulder keeping the attached product upright Transport in a road vehicle Never carry the product loose in a road vehicle as it can be affected by shock and vibration Always carry the product in its transport container and secure it Shipping When transporting the product by rail air or sea always use the complete original Leica Geosystems packaging transport container and cardboard box or its equivalent to protect against shock and vibration Shipping transport of batteries When transporting or shipping batteries the person in charge of the product must ensure that the applicable national and international rules and regulations are observed Before transportation or ship ping contact your local passenger or freight transport company Field adjustment After transport inspect the field adjustment parameters given in this user manual before using the product 11 2 Storage Product Respect the temperature limits when storing the equipment partic ularly in summer if the equipment is inside a vehicle Refer to 13 Technical Data for information about temperature limits Field adjustment After long periods of storage inspect the field adjustment parame ters given in this user manual before using the product If the equipment is to be stored for a long time remove the alkaline batteries from the product in order to avoid the danger of leakage 11 3 Cleani
5. Pont 2 Initiate measurement to Benchmark 10 Measurement repat Press ENTER kej to accept the result 3 Backsight measurement displayed 11 System refreshes a standby display for lt O measurement to the backsight of next change point 4 Measurement to foresight bel O Ce Mean average of height difference in double Fred BE sighting of backsight and foresight for BFFB line d H 5 Foresight measurement displayed levelling method lt 6 Measure to the foresight staff second 6 7 Timer Measurement i sighting resig Set measurement time interval 00 hr 00 min in Menu Settings Timer Press and hold measuring key for 3 seconds ohti to start timer measurement Timer icon will be shown at the top left i q rores ie nd sighti g measure of LCD display to indicate current measurement mode To stop timer measurement press and hold measuring key for 3 seconds 8 Measure to the backsight staff second sighting Operation 14 Sprinter 150 150M 250M 1 0 0en Wi Data Transfer DataLoader Double left click on the Sprinter_Dataloader exe setup launcher by default the DataLoader will be installed in C Program files Leica Geosystems 2 Connect the USB cable with phone jab to the connector port which is located in the battery compartment of the instrument and USB jab to the USB port at the PC 3 Power On the instrument wait for the double beeps and USB icon will be shown on the L
6. gt gt gt gt gt La 2135m Target prompted D a 3m 5 O Again press measure key to start measure Prompt message leasuring in leasurement to ment wiih reference to target point measure to target progress target displayed 6 The following results are displayed accord ingly target reduced level RL target height difference dH with respect to the reference staff height and distance of target point Operation mg Sprinter 150 150M 250M 1 0 0en Wie e Bim Je Bae Iw wee RfID BM1 RfID BM1 2 BM 100 038m BM 100 03am RAD BM D Elv 0 000m D Elv 100 500m ER 1 235m Meas Reference MeasReference gt 4 5 68m Change RAD BM amp Change RID BM amp ES D Elv goto menu D EWv goto menu leasure to Bench Goto menu update Measurement to mark with prompt Design Elevation Benchmark message displayed e BR m e KSE PHD SLAB1 Meas Target EN 99563m gt Lat 1710m A 0g37m Prompt message leasurement to measure to target target displayed Cut amp Fill Measurement internal Memory active Step Key Screen Description 1 Press Menu key and select Cut amp Fill applica menu tion in the Program sub menu lt 2 A message Meas Reference with input Benchmark reduced level value and Design Elevation is displayed 3 Press measuring key to initiate measurement with respect to the Reference staff Bench mark 4 Reference
7. risk of severe injury and rendering the environment liable to contamination Precautions The product must not be disposed with household waste Dispose of the product appropriately in accordance with the national regulations in force in your country Always prevent access to the product by unauthorized personnel Product specific treatment and waste management information can be downloaded from the Leica Geosystems home page at http www leica geosystems com treatment or received from your Leica Geosystems dealer WARNING Only Leica Geosystems authorized service workshops are entitled to repair these products 12 6 Electromagnetic Compatibility EMC Description The term Electromagnetic Compatibility is taken to mean the capability of the product to function smoothly in an environment where electro magnetic radiation and electrostatic discharges are present and without causing electromagnetic disturbances to other equipment WARNING Electromagnetic radiation can cause disturbances in other equipment Although the product meets the strict regulations and standards which are in force in this respect Leica Geosystems cannot completely exclude the possibility that other equipment may be disturbed CAUTION There is a risk that disturbances may be caused in other equipment if the product is used in conjunction with accessories from other manufacturers for example field computers personal computers two way radios
8. the product are responsible for developing implementing and commu nicating safety concepts for their products and are also responsible for the effectiveness of those safety concepts in combination with the Leica Geosystems product Person in charge of the product The person in charge of the product has the following duties To understand the safety instructions on the product and the instructions in the user manual To be familiar with local regulations relating to safety and acci dent prevention To inform Leica Geosystems immediately if the product and the application becomes unsafe WARNING The person responsible for the product must ensure that it is used in accordance with the instructions This person is also accountable for the training and the deployment of personnel who use the product and for the safety of the equipment in use 12 5 Hazards of Use WARNING The absence of instruction or the inadequate imparting of instruction can lead to incorrect or adverse use and can give rise to accidents with far reaching human material financial and envi ronmental consequences Precautions Allusers must follow the safety directions given by the manufacturer and the directions of the person responsible for the product CAUTION Watch out for erroneous measurement results if the product has been dropped or has been misused modified stored for long periods or transported Precautions Periodically carry out te
9. CD of the instrument 4 Start the DataLoader from default C Program files Leica Geosystems 5 Left click on USB Connect button in the DataLoader and all info relevant to instrument will be displayed 6 Left click on Data Listing Field Book button in the Data Export window to download the data from the instrument to PC in Window Ms Excel Ce For further DataLoader details and RS232 data transfer instructions please refer to the Sprinter CD ROM Data Transfer DataLoader si Sprinter 150 150M 250M 1 0 0en 8 Check 8 Adjust 8 1 Electronic Collimation Adjustment A A 15m 15m B To activate Adjustment program go to Menu Adjustment Step 1 Aim at Staff A and press MEAS key Measurement display press ENTER key to accept Step 2 Aim at Staff B and press MEAS key Measurement display press ENTER key to accept Now shift the Sprinter towards staff A and set it up at about 3 m to staff A 3m Step 3 Aim at Staff B and press MEAS key Measurement display press ENTER key to accept Step 4 Aim at Staff A and press MEAS key Measurement display press ENTER key to accept The new electronic collimation error is displayed To accept new correction press ENTER key otherwise press ESC key to decline adjustment result Cer Optical collimation error can be corrected by adjusting the reticle Check amp Adjust 16 Sprinter 150 150M 250M 1 0 0en WEG Circular Level
10. IP55 IEC 60529 tions Protection against Humidity Up to 95 humidity no condensation The effects of condensation are to be effectively counteracted by periodically drying out the product Dimensions Instrument e Length incl front of lens tube to fully extended eyepiece 219 mm e Width from the external face of focusing drive to the external side of circular bubble holder 196 mm e Height incl hand grip base fully extended 178 mm Container Length 400 mm Width 220 mm e Height 325 mm Weight 2 55 kg including 4 AA batteries Technical Data Sprinter 150 150M 250M 1 0 0en 14 International Warranty Soft ware Licence Agreement International Warranty The International Warranty can be downloaded from the Leica Geosystems AG home page at http Awww leica geosystems com internationalwarranty or received from your Leica Geosystems dealer Software Licence Agreement This product contains software that is preinstalled on the product or that is supplied to you on a data carrier medium or that can be downloaded by you online pursuant to prior authorization from Leica Geosystems Such software is protected by copyright and other laws and its use is defined and regulated by the Leica Geosystems Software Licence Agreement which covers aspects such as but not limited to Scope of the Licence Warranty Intellec tual Property Rights Limitation of Liability Exclusion of other Assur ances Governi
11. ON OFF Electronic tilt warning setting Backlight ON OFF Backlight setting Averaging Input number of measurement for averaging of measurements Language List of interface language selections Interface language setting Timer Input measurement time interval 00 hr 00 min applicable to Ht Dist application only Ce Press height distance or dH or backlight or menu key A message stop Tracking will be displayed User Interface na Sprinter 150 150M 250M 1 0 0en SS Set of Characters Benchmark Elevation BM Design Elevation D Elv BM and Design elevation numeric input consists of 0 9 space decimal Ft in 1 16 inch separator the and signs Point ID POD Point ID alphanumeric input consists of a z 0 9 and space Accepting character in the existing value If there is no change for any particular character in the existing entry field press ENTER key to accept the old entry Clearing all the existing entry field Highlight the first entry field with SPACE character and press ENTER key to clear the entire last input value To discard entry Press ESC key to discard entry and restore old value Point ID increment Point ID will be automatically incremented by 1from the last point ID if point ID input field is not updated manually 6 Operation Height and Distance measurement electronic Example of an electronic measurement E gt Always aim at the center o
12. Sprinter 150 150M 250M User Manual Version 1 0 e EN DE FR ES IT PT NL when it has to be right Seica NO SV FI DA Geosystems User Manual Gebrauchsanweisung Manuel d utilisation Manual del usuario Manuale d uso Manual de Opera o Gebruiksaanwijzing Brukerhandbok Handbok K ytt j n k sikirja Brugervejledning lot Wl User Manual English 1 Introduction Purchase Congratulations on the purchase of a new Leica Geosystems elec tronic level It is designed to make levelling works easier and quicker on any construction site Product This manual contains important safety direc A Pa tions as well as instructions for setting up the product and operating it Refer to 12 Safety Directions for further information Read carefully through the User Manual before you use the product Product identification The model and the serial number of your product are indicated on the type plate Enter the model and serial number in your manual and always refer to this information when you need to contact your agency or Leica Geosystems authorized service workshop Type Serial no Validity of this manual This manual is valid for Sprinter 150 150M 250M C amp gt Sections only valid for Sprinter 150M 250M are marked accordingly with an asterisk Trademarks All trademarks are the property of their respective owners Available documentation Name Description Sprinter All instructions
13. Symbols Measurement averaging activated PtID RfID Point ID Reference Benchmark ID dj Measured staff height BM Benchmark elevation d m Measured distance dH Height Difference dH Mean height difference in BFFB Elv Elevation A Fill raise height to reach design elevation D Elv Design Elevation aw Cut lower height to reach design elevation User Interface a oa Sprinter 150 150M 250M 1 0 0en EN Menu Setting Menus Selections sub selections Descriptions 1 Program Line Levelling BIF BF BFFB Select line levelling method CE Sighting and measurement sequence in line levelling is indicated with highlighted alphabet of the respective line levelling icons Cut Y amp Fill A Cut amp Fill application 2 Intermediate ON OFF Enable disable Intermediate Sight in BIF line levelling Sight 3 Input PtID Input user point ID 4 Input BM Input Reference Benchmark elevation 5 Input D ELV Input design elevation in Cut amp Fill application 6 Data View Data Viewing recorded data deleting of a recorded data by pressing ENTER key Manager Download Data GSI ASCII Transferring of recorded data to PC via RS232 in GSI 8 or ASCII format Delete All Data Deleting of all recorded data in the on board internal memory 7 Recording Memory Measurement recorded to on board internal memory C amp P In line levellin
14. Transfer DataLoader Design Elevation D Elv E Electronic Collimation Adjustment nab Error Messages s is Eyepiece 2 F Ha UL pia UWAWA AAA 2 G GUNSIGNE EE 2 H Height and Distance Mezeurement 9 Height Difference and Reduced Level Measurement 10 Input BM Input D ELV Input PtID Intermediate Sight Inverse Staff L Language LCD display Levelling footSCreW e tdiedte eietegbete gege eieetes degt 2 Index m a Sprinter 150 150M 250M 1 0 0en Measurement Display Symbols Measurement Mode MENU Menu Setting Modes o Operation Operation Messages i elei OT E 17 P Point UD AA Point ID increment Power ON PI Ia 7 R Recordi UA AAA Reticle Adjustment Rounding EE Sel Of Characters ia kaa 9 GEES H Set up Instrument Eyepiece Adjustment Levelling Target Image Focusing Storage Symbols T Timer Measurement Transport Index a OE Sprinter 150 150M 250M 1 0 0en
15. a in the internal memory is deleted Can t Delete Reference Benchmark and line levelling measurement not allowed to be deleted by single data deletion method Change BM Are You Sure Question to prompt user if changing of Reference Benchmark elevation to confirm Change Design Elevation Are You Sure Question to prompt user if changing of Design elevation to confirm Wait File System Clean Up Cleaning up of temporary files system files Shut Down System is switching OFF Sand Clock Icon Please wait System task is in progress Meas Target Aim to target staff and press measuring button Setting System parameter setting in progress Change Point not completed Quit Application Prompt message to quit application during line levelling process Complete current line levelling change point measurements then leave the application program Pressing ENTER key to quit application otherwise press ESC key to return to current application Quit This Application Prompt message to quit current application pressing ENTER key to quit application otherwise press ESC key to return to current application Operation Messages a a Sprinter 150 150M 250M 1 0 0en ST Care and Transport 11 1 Transport Transport in the field When transporting the eguipment in the field always make sure that you e either carry the product in its original transport container
16. easurement without recording OR download stored data to an external device and continue measurement with internal memory ON after deleting all recorded data in the internal memory E108 Data File Error Data file error E109 Low Memory Prepare to download data to external device in order to continue further measurement with recording ON after deleting all recorded data in the internal memory E110 Target Too Close Move staff or instrument further apart E111 Target Too far Move staff or instrument closer together E112 Too Cold Stop working external temperature is outside the instrument operating temperature E113 Too Hot Stop working external temperature is outside the instrument operating temperature Error Messages a Sprinter 150 150M 250M 1 0 0en HES No Error message Counter measure causes E114 Invalid Measurement Make another measurement If further measurement proved to be futile check staff position and Inverse Staff setting check the lighting condition at the staff and stray light check focusing and targeting check if sufficient length of barcode in the field of view E115 Temperature Sensor Cover the objective telescope with a hand and switch ON the instrument Hardware communication failed Error E116 Adjustment Error Carry out the adjustment with guided steps make sure instrument is level and staff is truly vertical in normal position Collimation is out of correc
17. eceived including inter ference that may cause undesired operation ST 3 Technical Data Height measurements Standard deviation per km double run ISO 17123 2 Electronic measurement with Sprinter aluminum barcode staff 1 0 mm Sprinter 250M 1 5 mm Sprinter 150 150M Optical measurement with standard aluminum E scale Numeral staff 2 5 mm Standard Deviation for single staff reading 0 6 mm electronic and 1 2 mm optical at 30m Distance Accuracy 10 mm for D lt 10 m Standard Deviation Distance in m x 0 001 for D gt 10 m Range fae measuring range for electronic measurements with standard aluminum barcode staff 2 m to m Optical Shortest focusing 50 cm distance Measuring time single Typically 3 seconds and less in normal daylight condition needs longer measuring time in uniform dim measure Electronic light condition 20 lux Circular Bubble Circular Bubble Sensitivity 1072 mm Compensator Magnet damped pendulum compensator with electronic range monitoring Tilt Warning Range Electronically 10 Compensator range Mechanically 10 Setting accuracy 0 8 max Standard Deviation Magnetic field sensitivity lt 10 Line of sight difference in horizontal constant magnetic field at a field strength of up 5 Gauss RS232 Port For RS232 cable connection to external battery and communication to PC data collector Phone Jab Port For USB cable connec
18. f bar code staff and focus the staff image for accurate meas urement E ES 6 1 Height and Distance Measurement lo aa di gt gt gt gt a S d gt gt gt gt Reif 5 68m Measurement leasuring in Measurement with Standby Mode progress height and distance Step Key Description Press to switch on the instrument Leica logo is displayed follow by the default measure ment standby mode Ia Aim at staff and focus Lightly trigger the measurement key to activate measurement 3 Height and distance measurement is displayed Set of Characters aaa a Sprinter 150 150M 250M 1 0 0en 6 2 Height Difference and Reduced Level Measurement internal Memory not HM active dH He MEAS Em dH Bm Step Key Screen Description ME Lai S35 Press key to start height diff d a 1 235m 1 ress key to start height difference an Fees reduced level function Wa rr wes gt a 56n ui ponme 2 A message Meas Reference with input easure to Bench Measuring in leasurement to reduced level is displayed mark with prompt progress SC 3 Press measuring key to initiate measurement message Isplaye with respect to the Reference staff Bench dH Em f Em dH Em mark Meas Target Be Elv 99138m 4 Reference height and distance measurement i i dH dH 0900m is displayed follow by a message Meas gt a
19. fication or conversion of the product Use after misappropriation Use of products with obviously recognizable damages or defects Safety Directions ae Sprinter 150 150M 250M 1 0 0en Use with accessories from other manufacturers without the prior explicit approval of Leica Geosystems Inadequate safeguards at the working site for example when measuring on roads e Aiming directly into the sun WARNING Adverse use can lead to injury malfunction and damage It is the task of the person responsible for the equipment to inform the user about hazards and how to counteract them The product is not to be operated until the user has been instructed on how to work with it 12 3 Limits of Use Environment Suitable for use in an atmosphere appropriate for permanent human habitation not suitable for use in aggressive or explosive environments DANGER Local safety authorities and safety experts must be contacted before working in hazardous areas or in close proximity to electrical installations or similar situations by the person in charge of the product 12 4 Responsibilities Manufacturer of the product Leica Geosystems AG CH 9435 Heerbrugg hereinafter referred to as Leica Geosystems is responsible for supplying the product including the user manual and original accessories in a completely safe condition Manufacturers of non Leica Geosystems accessories The manufacturers of non Leica Geosystems accessories for
20. g application recording mode has to be set prior to first backsight measurement Off Measurement not stored Ext Measurement recorded to external device in GSI 8 format via RS232 cable 8 Adjustment Adjustment program 9 Inverse Staff ON Inverted OFF Upright AUTO Recognition mode setting of staff orientation Auto recognition of staff orientation User Interface aol Sprinter 150 150M 250M 1 0 0en Menus Selections sub selections Descriptions 10 Settings Contrast 10 levels LCD display contrast setting Unit M Int ft US ft Ft in 1 16 inch Unit setting AutoOff ON 15 min OFF ON 15 min instrument will be switched off about 15 minutes after the last key press OFF the instrument will not auto switch off Rounding Standard Precise Minimum reading display setting In metric Standard 0 001m for height and 0 01m for distance Precise 0 0001 m for height and 0 001m for distance In Ft Int and US ft Standard 0 01 ft for height and 0 1 ft for distance Precise 0 001 ft for height and 0 01 ft for distance In Ft in 1 16 inch Precise amp Standard ft inch 1 16 inch for height and distance Beep ON OFF Trigger key acoustic signal setting RS232 Baudrate 1200 2400 4800 9600 19200 38400 Parity None Odd Even Stop Bit 1 2 Data Bit 7 8 Communication settings for RS232 interface Tilt Warning
21. he risk of being struck by lightning Precautions Do not use the product in a thunderstorm ob CAUTION During the operation of the product there is a hazard of squeezing extremities or entanglement of hairs and or clothes by rotating parts Precautions Keep a safe distance of the rotating parts WARNING If you open the product either of the following actions may cause you to receive an electric shock Touching live components Using the product after incorrect attempts were made to carry out repairs Precautions Do not open the product Only Leica Geosystems authorized service workshops are entitled to repair these products WARNING Batteries not recommended by Leica Geosystems may be damaged if charged or discharged They may burn and explode Precautions Only charge and discharge batteries recommended by Leica Geosystems WARNING Using a battery charger not recommended by Leica Geosys tems can destroy the batteries This can cause fire or explosions Precautions Only use chargers recommended by Leica Geosystems to charge the batteries CAUTION During the transport shipping or disposal of batteries it is possible for inappropriate mechanical influences to constitute a fire hazard Precautions Before shipping the product or disposing of it discharge the batteries by running the product until they are flat When transporting or shipping batteries the person in charge of the product must ensure that the appl
22. height and distance measurement is displayed follow by a message Meas Target prompted 5 Again press measure key to start measure O ment to target point 6 The following results are displayed accord ingly target reduced level RL Elevation height of target point and cut fill value at target point with respect to the Design reduced level Design Elevation Operation nu Sprinter 150 150M 250M 1 0 0en 6 4 DIE 58m PtD 1 Elv 420000m Meas to backsight gt To change Elv amp PtID igoto menu Measure to backsight with prompt message Measure to next interme diate sight with prompt message Backsight measurement displayed with prompt message Go to menu set Interme diate Sight to OFF OR press Height amp Distance key measure to foresight BI Bm PtID 2 Ess m Kar ui m gt ae m B F Menu Measure to foresight with prompt message PED 2 Foresight measurement displayed with prompt message BIF Line Levelling Measurement internal Memory active BIF iam PtiD RD1 Eege m E Ke m gt E Lee m BIF Menu Go to menu set Interme diate Sight to ON OR press Height amp Distance key measure to interme diate sight Measure to backsight of next change point with prompt message RD1 119 317m 2 100m 30 617m Accept Intermediate sight measurement displayed with prompt message
23. icable national and international rules and regulations are observed Before transportation or ship ping contact your local passenger or freight transport company WARNING High mechanical stress high ambient temperatures or immersion into fluids can cause leackage fire or explosions of the batteries Precautions Protect the batteries from mechanical influences and high ambient temperatures Do not drop or immerse batteries into fluids WARNING Short circuited battery terminals can overheat and cause injury or fire for example by storing or transporting in pockets if battery terminals come in contact with jewellery keys metallized paper or other metals Precautions Make sure that the battery terminals do not come into contact with metallic objects Safety Directions ees Sprinter 150 150M 250M 1 0 0en CAUTION Long term storage may reduce lifetime or damage the battery Precautions During long term storage maintain battery life by periodic re charge WARNING If the product is improperly disposed of the following can happen If polymer parts are burnt poisonous gases are produced which may impair health If batteries are damaged or are heated strongly they can explode and cause poisoning burning corrosion or environ mental contamination By disposing of the product irresponsibly you may enable unau thorized persons to use it in contravention of the regulations exposing themselves and third parties to the
24. l Data jab interface for USB cable h LCD display 14 International Warranty Software c Ge i Pase pale A Licence Agreement 32 d Gunsig j Levelling foot e Focusing knob screw dr Mde ait Niii iise elei tie Micaphlbies 33 Container Contents Sprinter batteries 4x allen key user manual strap CD ROM incl DataLoader USB cable Instrument Components aa Sprinter 150 150M 250M 1 0 0en Accessories Tripod aluminum staff region dependant fibre glass staff to achieve 0 7 mm accuracy with Sprinter 250M Optional sunshade 4 rechargeable batteries and charger 3 Measurement Preparations 3 1 Change Battery Insert 4 AA dry cells according to the positive and negative signs as indicated on the holder gt Always replace with a complete battery set Ce Do not use old and new batteries together Ce Do not use batteries from different manufacturers or batteries of different types 3 2 Set up Instrument Levelling Setup the tripod Extend the legs to a suitable length and ensure that the tripod head is approximately level Tread the tripod shoes firmly into the ground to ensure stability Mount the instrument on the tripod by screwing the tripod screw onto the base of the instrument Use the three levelling foot screws to center the circular bubble in order to level the instrument Eyepiece Adjustment Point the telescope to a uniform light surface such as a wall or a piece of paper Turn the eyepiece u
25. ng Law and Place of Jurisdiction Please make sure that at any time you fully comply with the terms and conditions of the Leica Geosystems Software Licence Agreement Such agreement is provided together with all products and can also be found at the Leica Geosystems home page at http Awww leica geosystems com swlicense or your Leica Geosystems dealer You must not install or use the software unless you have read and accepted the terms and conditions of the Leica Geosystems Software Licence Agreement Installation or use of the software or any part thereof is deemed to be an acceptance of all the terms and condi tions of such licence agreement If you do not agree to all or some of International Warranty Software Sprinter 150 150M 250M 1 0 0en Licence Agreement the terms of such licence agreement you may not download install or use the software and you must return the unused software together with its accompanying documentation and the purchase receipt to the dealer from whom you purchased the product within ten 10 days of purchase to obtain a full refund of the purchase price 15 Index A Accessories Adjustment Mode AutoOff Averaging B Backlight Base plate Battery Battery compartment Change Battery Baudrate BF Check amp Adjust Circular Level Cleaning and Drying Components Container Contents Contrast Cut amp Fill D Data Display Symbols Data Manager Data
26. ng and Drying Product and Accessories Blow dust off lenses e Never touch the glass with your fingers Use only a clean soft lint free cloth for cleaning If necessary moisten the cloth with water or pure alcohol Do not use other liquids these may attack the polymer compo nents Damp products Dry the product the transport container the foam inserts and the accessories at a temperature not greater than 40 C 104 F and clean them Do not repack until everything is completely dry Care and Transport oa Sprinter 150 150M 250M 1 0 0en 12 Safety Directions 12 1 General Introduction Description The following directions should enable the person responsible for the product and the person who actually uses the eguipment to anticipate and avoid operational hazards The person responsible for the product must ensure that all users understand these directions and adhere to them 12 2 Intended Use Permitted use Measuring distances Recording measurements Electronic and optical height measurements to a staff Optical height readings Optical distance measuring with stadia readings Data communication with external appliances Adverse use Use of the product without instruction Use outside of the intended limits Disabling safety systems Removal of hazard notices Opening the product using tools for example screwdriver unless this is specifically permitted for certain functions Modi
27. ntil the cross hairs are sharp or distinct Target Image Focusing Use the gunsight to aim the objective lens at the staff Turn the hori zontal fine motion screw until the staff is nearly centered in the field of view and then turn the focusing knob to focus on the staff Ensure that staff image and reticle are sharp or distinct Power ON The instrument is ready to measure C Technical hints First check and adjust the electronic and optical line of sight errors then the circular level on the instrument and then the staff before starting work in the field after long storage periods after long transportation Keep the optics clean Dirt or condensation on the optics can limit measurements e Before starting work let the instrument adjust to the ambient temperature approx 2 minutes per C of temperature differ ence Avoid measuring through window panes Staff sections have to be fully extended and properly secured Touching the upper third of the tripod can damp vibrations at the instrument due to wind Use the lens hood to cover the objective when backlight disturbs Evenly illuminate the measuring area of the staff with a flashlight or spotlight in darkness Measurement Preparations R Sprinter 150 150M 250M 1 0 0en 4 User Interface 270 Tevel functions b MEAS O Key Symbol 1 level functions a On Off ER Power On or Off switch NONE d Meas
28. o comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communication However there is no guarantee that interference will not occur ina particular installation If this equipment does cause harmful interference to radio or televi sion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARNING Changes or modifications not expressly approved by Leica Geosystems for compliance could void the user s authority to operate the equipment Safety Directions is Sprinter 150 150M 250M 1 0 0en Labelling This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harm ful interference and 2 this device must accept any interference r
29. re of the existing dangers WARNING Inadequate securing of the working site can lead to dangerous situations for example in traffic on building sites and at industrial installations Precautions Always ensure that the working site is adequately secured Adhere to the regulations governing safety and accident prevention and road traffic Safety Directions IM Sprinter 150 150M 250M 1 0 0en WARNING If computers intended for use indoors are used in the field there is a danger of electric shock Precautions Adhere to the instructions given by the computer manufacturer with regard to field use in conjunction with Leica Geosystems products CAUTION If the accessories used with the product are not properly secured and the product is subjected to mechanical shock for example blows or falling the product may be damaged or people may sustain injury Precautions When setting up the product make sure that the accessories are correctly adapted fitted secured and locked in position Avoid subjecting the product to mechanical stress CAUTION When using a vertical staff supported by one brace there is always the danger of falling for example by wind gusts and therefore danger of damage to equipment and danger of personal injuries Precautions Never leave a vertical staff supported by a brace unsupervised person at the staff WARNING If the product is used with accessories for example masts staffs poles you may increase t
30. required in order to operate the Manual 150 150M product to a basic level are contained in this User 250M User Manual Provides an overview of the system together with technical data and safety directions Symbols The symbols used in this Manual have the following meanings DANGER Indi icates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indi use which icates a potentially hazardous situation or an unintended if not avoided could result in death or serious injury CAUTION Indi use which icates a potentially hazardous situation or an unintended if not avoided may result in minor or moderate injury and or appreciable material financial and environmental damage C amp gt Important paragraphs which must be adhered to in practice as hey enable the product to be used in a technically correct and efficient manner Introduction as a Sprinter 150 150M 250M 1 0 0en Table of Contents 2 Instrument Components EN INtrOGUCHION eege EC Instrument Components Measurement Preparations User Interface Set of Characters Operation Data Transfer DataLoader Check amp Adjust Error Messages 10 Operation Messages Care and Transport 12 Safety Directions Oo So NO E ZS ON a Horizontal fine motion screw f Handle b Battery compartment incl phone g Eyepiece h 13 Technica
31. st measurements and perform the field adjustments indicated in the user manual particularly after the product has been subjected to abnormal use and before and after important measurements DANGER Because of the risk of electrocution it is very dangerous to use staffs in the vicinity of electrical installations such as power cables or electrical railways Precautions Keep at a safe distance from electrical installations If it is essential to work in this environment first contact the safety authorities respon sible for the electrical installations and follow their instructions CAUTION Strong magnetic fields in the immediate vicinity e g trans formers melting furnaces may influence the compensator and lead to measuring errors Safety Directions Sas Sprinter 150 150M 250M 1 0 0en Precautions When measuring near strong magnetic fields check results for plausibility CAUTION Be careful when pointing the product towards the sun because the telescope functions as a magnifying glass and can injure your eyes and or cause damage inside the product Precautions Do not point the product directly at the sun WARNING During dynamic applications for example stakeout proce dures there is a danger of accidents occurring if the user does not pay attention to the environmental conditions around for example obstacles excavations or traffic Precautions The person responsible for the product must make all users fully awa
32. tion range E117 BM Change Not Allowed Exit to default measurement mode by pressing HEIGHT DISTANCE key and change the Benchmark elevation in the INPUT BM menu mode E119 Staff Blocked Not enough barcode length for measurement E120 Image sensor Error Contact services E121 Adjustment Inverse Staff Check the staff orientation and staff setting Not Allowed E123 PD Change Not Allowed Exit the message by pressing ESC key 10 Operation Messages Operation message Counter measure remark Start Tracking Tracking mode starts Stop Tracking Tracking mode stops Tracking Hold Press measure key for 3 seconds to restart tracking mode Tracking will hold after 10 unsuccessful meas urements Abort Measurement Current measuring process is terminated Downloading Data Downloading of data from the internal memory to an external device is in progress Operation Messages Im Sprinter 150 150M 250M 1 0 0en Operation message Counter measure remark Download Completed System is successfully downloaded the internal memory data to an external device No Data In Memory No data is stored in the internal memory Delete Are You Sure Questionnaire prompted user to confirm the deletion of a data in View Data mode all the data in Delete All Data mode in the internal memory Data Deleted System confirmation a data or all the dat
33. tion to communication to PC Technical Data e ae Sprinter 150 150M 250M 1 0 0en Internal Memory Storage Capacity up to 1000 points Data Transfer Program To DataLoader via USB to Leica Geo Office and HyperTerminal via RS232 on PC using a Windows application Power Supply Sprinter 150 internal battery Sprinter 150M 250M internal battery and external via RS232 port Battery Power Battery internal AA dry cells 4 x 1 5 V powered via RS232 port Nominal voltage 12 V voltage range 4 xx V GEV71 power cable to a 12 V car battery current rating max 300 mA LCD Type Monochrome display with backlight capability Dimensions 128 x 104 pixels Telescope agnification Optical 24 x Free objective diameter 36 mm lear Objective Aperture 2 ultiplication constant 100 Addition constant 0 CH Hz Circle Circle Engraving Plastic horizontal circle of 360 400 gon Graduation and numerals scale resolution at 1 upper scale and at 50 gon intervals lower scale Side Drive Movement amp Play in side drive Continuous horizontal dual drive System MMI capability Measuring applications Keyboard 5 rubber keys Temperature Range Operating Temperature 10 C to 50 C Storage Temperature 40 C to 70 C Technical Data a e Sprinter 150 150M 250M 1 0 0en Environmental Specifica Protection against water dust and sand
34. uring trigger key Press and hold for 3 seconds to start and stop tracking measurement timer measurement c Height Zl Distance ZA Alternating between Height and Distance display Cursor up in Menu Settings mode Switch between intermediate sight and foresight F in line leveling program BIF Sprinter 150 150M 250M 1 0 0en User Interface Key Symbol 715 level functions 279 Tevel functions d dH Height Difference and Elevation meas Cursor down in Menu Settings mode urement v e MENU wenu Activation and Selection of settings ENTER key for confirmation purpose ES f Backlight LCD backlight illumination ESC key to decline termination of program application or to exit setting ECH in Menu Settings mode ESC Modes Measurement Mode BF line levelling MEAS EF Bal j MENU BFFB line levelling MENU FFB BRFB BFRB DEER BFFB Adjustment Mode BIF line levelling i gr BF BE i Trackin Cut amp Fill i e Settings Height Difference SET dH s Measurement interval timer acti vated User Interface ees Sprinter 150 150M 250M 1 0 0en Vly LCD backlight ON Battery icon at various capacities K TEDO Upright staff measuring mode Data stored to internal memory Tilt warning OFF RO H Inverted staff measuring mode Er External power connected Measurement and Data Display

Download Pdf Manuals

image

Related Search

Related Contents

Jean-Louis Soulier - Saint-Quentin-en  septembre – décembre 2010  Jean-Pierre Lachaud  Interquartz 9281B3 telephone  SMART NS Hand SMART NS Foundry SMART NS Arc  Carnet de voyage pour les 6-12 ans - Albert Kahn - Hauts-de  ProScan PLT1077-G (BT-512-8GB) User's Manual  EZPAD 910C USER MANUAL.pub  Massive Cucina Other 33452/17/10  iLuv iMM190  