1. ees Figure 6 2 PCM 8712 MB Bottom POC W181 User Manual 24 Connector List Top Side No Description CN63 LCD Panel Back Light Connector CN11 LVDS Connector CN66 Back up Battery Connector PCN2 18VDC Input Connector CN3 DVI I Connector CN48 LAN2 Connector CN42 LAN1 Connector CN57 COM1 CN58 COM2 CN54 Speaker R CN55 Speaker L CN24 Internal USB Reserved CN44 External USB w USB Cable CN22 Bluetooth Connector SW1 Power Button DeBug Only Bottom Side No Description CN33 Front Button Board Connector POC W181 CN41 External USB w USB Cable CN23 Internal USB Reserved CN56 COM1 RS232 422 485 Setting Jumper CN60 RTC Battery Connector CN1 Clear CMOS CN2 Clear ME SW3 Panel Type Selection SW2 Panel Type Selection CN65 Back up Battery Signal Connector CN30 Touch Sensor Connector CN17 SATA HDD Signal Connector CN18 SATA HDD Power Connector CN36 Front Button Board Connector POC Cart CN8 System Reset Connector CN45 Touch Sensor Enable Connector Reserved 25 POC W181 User Manual Jumper List MB CN1 Clear CMOS CN2 Clear ME SW2 SW3 VBIOS Setup CN4 ME Manufacturing Mode CN8 System Reset CN56 1
2. Figure 2 2 Rear View of the Point of Care Terminal Figure 2 3 Rear View of Multi I O Ports 1 9 POC W181 User Manual 12 Figure 2 4 Rear View of Multi I O Ports 2 2 2 and 2 3 Rear View pop Se po s 9 10 11 12 mounting 100mmx100mm 75mmx75mm DC IN Jack DVI I port Gigabit Ethernet network ports labeled TCP IP LAN2 Gigabit Ethernet network ports labeled TCP IP LAN1 COM 1 port COM 2 port Dove tail Equipotential terminal USB x2 ports USB x2 ports Dove tail 2 1 3 Bottom View Figure 2 5 Bottom View 13 Smart card reader option 14 Speaker x 2 POC W181 User Manual 10 Note Equipotential terminals need a link to hospital ground earth system before system boot to protect operator and system d 2 2 Installation Procedures 2 2 1 Connecting the Power Cord The POC W181 can only be powered by DC power adapter SINPRO Model no HPU100 107 Be sure to always handle the power cords by holding the plug ends only Follow these procedures in order 1 Connect the female end of the power adapter to the DC jack of the panel PC See Figure 2 7 2 Connect the female end of the power cord to the DC power adapter 3 Connect the 3 pin male plug of the power cord to an electrical outlet Step 1 Separate Purchase en 8 Figure 2 6 Connectin
3. VESA Mounting 75 x 75 mm 100 x 100 mm Figure 1 2 VESA Mounting POC W181 User Manual 4 Warning Use suitable mounting apparatus to avoid risk of injury A Optional Modules Memory 2GB 4GB DDR3 1333 MHz SDRAM HDD 2 5 SATA HDD W Touchscreen Analog resistive Point of Care Terminal Cleaning and Disinfectin During normal use of the POC Point of Care Terminal the device may become dirty and should be regularly cleaned Steps 1 Prepare cleaning agent per manufacturer s instructions or hospital protocol 2 Wipe the POC with a clean cloth that has been moistened in the cleaning solu tion 3 Wipe thoroughly with a clean cloth Cleaning agent list chemical disinfectants which have been tested on the POC z Cleaning Agents Cidex Isopropyl alcohol Green tinctured soap Windex Alcohol Alcohol 70 Chloride 1000PPM Incidin plus Incidin liquid Mikrozid liquid olo NIIAJ BR N e Caution Do not immerse or rinse the POC W181 or its peripherals If you acci dentally spill liquid on the device disconnect the unit from the power A source Contact your Biomed department regarding the continued safety of the unit before placing it back in operation Do not spray cleaning agent on the chassis Do not use disinfectants that contain phenol Do not autoclave or clean the 181 or its peripherals with strong aromatic chlorinated ketone
4. Graphics Controller Integrated Intel amp HD Graphics Expansion Slot Mini PCle 1 x mini PCle Storage HDD 1x2 5 SATA Identification 1x Smart Card Reader option Ethernet Interface 2 x Gigabit Ethernet isolated interface RJ 45 I O Ports 1 x RS 232 isolated and 1 x RS 232 422 485 iso lated serial port 4 x USB 2 0 ports 1 x DVI I port 1 x DC in Jack Speakers 2x2W speakers POC W181 User Manual 2 Display size 18 5 TN Mode LED panel Display Mode TN Normally white Max Resolution 1366 x 768 WXGA Max Colors 16 7M colors RGB 6 bit Hi FRC Display Dot Size mm 0 282 x 0 282 Viewing Angle 170 160 Luminance 250 cd m Backlight LED Contrast Ratio 1000 1 DC Model AC adapter Sinpro Model no HPU101 107 Power Supply Input Voltage 90 260V AC 47 63Hz 1 35 0 5A Output Voltage 18 VDC 5 55 A max 100 watts Battery 352 4200mAH Smart Card Reader supporting ISO IEC 7816 1 2 3 Opti WLAN IEEE 208 11 b g n ptions RFID Supports ISO14443A B and 15693 standard Bluetooth Supports CSR bluetooth 2 0 Enhanced Data Rate EDR Type Analog Resistive Resolution Continuous Optional Light Transmission 80 Touchscreen Controller USB interface Durability 35 million touches EF B d Certifications eee A UL60601 1 EN60601 1 approved Temperature 0 35 C 32 95 F Operating 20 60 C Storage 20 60 C Transportation Hu
5. 1 2 System Reset No Connect Normal Operation Default POC W181 User Manual COM 1 Jumper setting RS 232 RS 422 RS 485 RS 485 2 Wires type RS 422 4 Wires type 28 Chapter 1 Front Bezel Button 7 1 Introduction The POC W181 front button function description Front button map b Button description Power button Press this button to power on off system When system this icon will become Green color LED is off when system is off Reduce volume B Press this button to reduce speaker and headphone volume Increase Volume eb Press this button to increase speaker and headphone vol ume Touch disable Press this button to disable enable touch function With touch function enabled this icon will become green With touch function disabled this LED will be off Read light Press this button to enable disable read light Reduce brightness Press this button to reduce LCD backlight brightness Increase brightness Press this button to increase LCD backlight brightness Combination button Backlight off is a special function When you press both reduce brightness and increase brightness buttons for half second LCD backlight will be turned off And pressing both buttons for half a second again will turn on the LCD backlight When backlight is off tte POC W181 system is still running The backlight does not impact any programs
6. POC181 W7 Onekey Installation The Install dialog will appear Step 2 Please follow the instruction to install drivers POC 127 User Manual 18 Chapter 4 Utilities and Hot fixes 4 1 4 2 4 2 1 Introduction The POC W181 system needs specific utilities or hot fixes to support special func tions Wakeup by External USB Device at S3 Resume Wakeup POC W181 supports three different sleep suspend modes they are 1 S1 Power On Suspena system will stop the clock turn off LCD backlight but keep all power on User can press any key mouse or keyboard to wakeup sys tem S3 Suspend to RAM system will stop the clock turn off most power rails but not power to memory power All necessary information will be saved to memory In this sleep mode Windows XP system needs a hot fix to wakeup the system by USB mouse or keyboard S4 Suspend to Disk Hibernation system will stop the clock turn off most power including power to memory All necessary information will be saved to Hard Disk In this sleep mode user needs to press the power button to wakeup the system Installation for Windows XP This utility is an optional tool Only install it when USB wakeup up function is needed Only WIN XP needs this utility Please don t install it on WIN7 OS Step 1 Double click the USBRG REG in Driver DVD Drivers and Utilities POC181 XPP OnekeylnstallationUSB folder Step 2 Click Yes to install this regist
7. RS232 422 485 output type setting 3 0 CN1 Clear CMOS Description Clear CMOS Setup Setting Function 1 2 Clear CMOS Setup No Connect Normal Operation Default 2 0 CN2 Clear ME Description Clear ME Setup Setting Function 1 2 Clear ME Setup No Connect Normal Operation Default POC W181 User Manual 26 Panel Resolution Select sw2 Hi LT Lo n EF Lo SW3 Hi Lo Hi Lo GPIO39 GPIO48 GPIO34 Panel Resolution Select SW2 1 SW2 2 SW3 1 Hi OFF Lo ON Lo ON 24 bit single channel 1024x768 Lo ON Hi OFF Lo ON 24 bit dual channels 1280x1024 Lo ON Lo ON Lo ON 24 bit dual channel 1680x1050 Hi OFF Hi OFF Lo ON Manual setting Hi OFF Lo ON Hi OFF 24 bit dual channels 1920x1080 Lo ON Hi OFF Hi OFF 24 bit single channels 1366x768 Default Lo ON Lo ON Hi OFF TBD Hi OFF Hi OFF Hi OFF TBD SW3 Hi Lo Hi Lo SW3 2 Main Display Setup Description Select boot main display setting Setting Function Lo Set VGA as main display at bootup Hi Set LVDS as main display at bootup CN4 ME Manufacturing Mode Description ME Manufacturing Mode Setting Function 1 2 ME Manufacturing Mode No Connect Normal Operation Default 27 POC W181 User Manual 2 e CN8 System Reset Description System Reset Setting Function
8. assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance The model POC W181 uses RF energy only E for its internal function Therefore its RF emis RF emissions Group 1 sions are very low and are not likely to cause CISPR 11 _ any interference in nearby electronic eguip ment RF emissions Class B The model POC W181 is suitable for use in all CISPR 11 emissions establishments including domestic establish Class A ments and those directly connected to the pub IEC 61000 3 2 lic low voltage power supply network that Voltage fluctuations supplies buildings used for domestic pur flicker emissions Not applicable poses IEC 61000 3 3 Recommended separation distances between portable and mobile RF communications equipment and the model POC W181 Model POC W181 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the model POC W181 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the model POC W181 as rec ommended below according to the maximum output power of the communications equip ment Rated Separation distance according to frequency of transmitter maximum m output power of 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5
9. ether or Esther solvents sharp tools or abrasives Never immerse electrical connectors in water or other liquids 5 POC W181 User Manual POC W181 User Manual Chapter 2 System Setup 2 1 A Quick Tour of the POC W181 Before you start to set up the POC W181 take a moment to become familiar with the locations and purposes of the controls drives connections and ports which are illus trated in the figures below When you place the POC W181 upright on the desktop its front panel appears as shown in Figure 2 1 2 1 4 Front View VATI 2 3456 77 Figure 2 1 Front View of the Point of Care Terminal 2 1 Front Bezel view LCD panel with Touchscreen option Power button w indicator light Power on Green light Volume control Read light Touchscreen control w indicator light Read light control Brightness control NOaRWN gt POC W181 User Manual 8 2 1 2 Rear View When you turn the Point of Care Terminal around and look at its rear cover the sunken I O section is at the bottom of the panel PC as shown in Figure 2 2 Figure 2 and Figure 2 4 The I O section includes various I O ports including serial ports DVI port the Ethernet port USB ports and so on
10. operating This backlight off function can be used in a hospital environment If the operator needs to check X Rays in a dark room turning off the backlight quickly will prevent interference in the dark room Operator can turn off backlight at night to prevent interfering with patient s sleep POC W181 User Manual 30 POC W181 Advanced BIOS Functions 8 1 Introduction This section Introduces the advanced functions in the POC W181 BIOS menu Power Button Function Enable Disable You can enable disable power button function in BIOS menu If you disable the power button in SO System ON status the power button will not work So the user cannot turn off the system via the power button In this case the user needs to use software to turn off system This function can pre vent touching the power button by mistake resulting in a system shutdown BIOS Menu location BIOS Menu Advanced Embedded Controller Configuration Power Button Function BEnable Power button function works when system in SO System ON status Default Disable Power button function does not work when system is in SO System ON status User needs to press power button 5 seconds or more to trigger power button Brightness Button Control You can enable disable LCD Backlight button function in BIOS menu If you disable the LCD Backlight button this button will not work So the user cannot adjust LCD backlight luminance by this button This funct
11. 2 General Information 1 Introduction 2 Specification S EE 2 Table 1 1 Specifications 2 Figure LT DIMENSIONS ebd n ener d 4 Figure 1 2 Mounting 4 System Setup 7 A Quick Tour of the POC W181 sssssssssseeem em 8 242 JEFODEVIGW 2a ae 8 Figure 2 1 Front View of the Point of Care Terminal 8 2 1 2 Rear VIGW 4 te ec tne Se ER Pe rb 9 Figure 2 2 Rear View of the Point of Care Terminal 9 Figure 2 3 Rear View of VO 1 9 Figure 2 4 Rear View of Multi VO 2 10 2 1 9 Bottom View rd dede 10 Figure 2 5 Bottom View 10 Installation 1 1 44 414 2 4 11 2 2 1 Connecting the Power 11 Figure 2 6 Connecting the Power Cord 11 2 2 2 Connecting the Ground Pin 12 Figure 2 7 POC W181 Equipotential Terminal Pin 12 Figure 2 8 Grounding Cable with Connector 12 2 2 3 Switch on the Power 13 Figure 2 9 Press the Power Button to Boot System 13 Running the BIOS Setup 13 Installing
12. GHz transmitter 4 1 2 4 1 2 d 2 3 F W 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended sepa ration distance d in meters m can be estimated using the equation applicable to the fre quency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people vii POC W181 User Manual Information on potential electromagnetic interference and advice on how to avoid or minimize such interference IEC EN 60601 1 2 2007 Guidance and manufacturer s declaration electromagnetic immunity Model POC W181 is intended for use in the electromagnetic environment specified below The customer or the user of the model POC W181 should assure that it is used in such an environ ment 60601 test Compliance Electromagnetic environment guid Immunity test level level ance Electrostatic Floors should be wood concrete or discharge 6 kV contact 6 kV contact ceramic tile If floors are covered with ESD 8 kV air 8 KV air synthetic material the relative humidity IEC 61000 4 2 sho
13. POC W181 Intel i7 Processor 2610UE Point of Care Terminal with 18 5 TFT LCD AD ANTECH Enabling an Intelligent Planet Instructions for User This document combines text and illustrations providing a comprehensive overview of the system The information is presented as sequential steps of action allowing the user to learn directly how to use the device The text provides explanations and instructs the user step by step in the practical use of the product with short clear instructions in easy to follow sequence Definitions Warning A WARNING statement provides important information about a poten tially hazardous situation which if not avoided could result in death or A serious injury Caution A CAUTION statement provides important information about a poten tially hazardous situation which if not avoided may result in minor or A moderate injury to the user or patient or in damage to the equipment or other property Note NOTE provides additional information intended to avoid inconve niences during operation Part No 2008018110 Edition 1 Printed in Taiwan July 2012 POC W181 User Manual ii Safety Instructions Strictly follow these Instructions for Use please read these safety instructions care fully Keep this User s Manual for later reference Any use of the product requires full understanding and strict observation of all portions of these instructions Observe all WARNINGS and CAUTIONS as render
14. System Software 13 Installing the Drivers aria ape 14 Table 2 1 File Directory on Drivers and Utilities DVD 15 Troubles Noong rss ee 16 Driver Installation 17 INTFOQUETION PERRO E EET RIT 18 Automatic Driver Installation s 18 Utilities and Hot fixes 19 neuesten 20 Wakeup by External USB Device at S3 Resume Wakeup 20 4 2 4 Installation for Windows XP e 20 Operation and Safety information 21 General Safety Guide 22 II 22 PCM 8712 Connector Map and Table xiii POC W181 User Manual Chapter 7 7 1 Chapter 8 8 1 POC W181 User Manual 23 Figure 6 1 PCM 8712 MB 24 Figure 6 2 PCM 8712 MB Bottom 24 Front Bezel Button 29 Introduction nee ea eu eu 30 POC W181 Advanced BIOS Functions 31 Introduction EORR T 32 xiv Chapter 1 General Information 1 1 Introduction The POC W181 is a multimedia Intel Core i Series Mobility processor based com puter that is designed to serve as a Point of Care terminal POC It is a PC based system with 18 5 wide screen TFT LCD display Single DVI I Port HDMI Dual on board 10 100 1000 PCI E Ethernet controller one LAN port
15. ed throughout this manual and on labels on the equipment Repair of the device may only be carried out by trained service personnel Advantech recommends that a service contract be obtained with Advantech Service and that all repairs also be carried out by them Otherwise the correct functioning of the device may be compromised Warning Because of the danger of electric shock never remove the cover of a device while it is in operation or connected to a power outlet If one of the following situations arises have the equipment checked by service per sonnel a The power cord or plug is damaged b Liquid has penetrated into the equipment c The equipment has been exposed to moisture d The equipment does not work well or you cannot get it to work according to the user s manual e The equipment has been dropped and damaged f The equipment has obvious signs of breakage Disconnect this equipment from any AC outlet before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning and keep this equipment away from humidity Caution To avoid short circuiting and otherwise damaging the device do not allow fluids to come in contact with the device If fluids are accidentally A spilled on the eguipment remove the affected unit from service as soon as possible and contact the service personnel to verify that patient safety is not compromised Put this equipment on a reliable surface during installation Drop
16. ety Collateral standard Electromagnetic compatibility Requirements and tests SSIF a le C US XXXX Medical Equipment With Respect To Electric Shock Fire And Mechanical Hazards Only In Accordance With ANSI AAMI ES60601 1 CAN CSA C22 2 No 60601 1 Accessory equipment connected to the analog and digital interfaces must be in com pliance with the respective nationally harmonized IEC standards i e IEC 60950 for data processing equipment IEC 60065 for video equipment IEC 61010 1 for labora tory equipment and IEC 60601 1 for medical equipment Furthermore all configura tions shall comply with the system standard IEC 60601 1 1 Anyone who connects additional equipment to the signal input part or signal output part is configuring a medical system and is therefore responsible that the system complies with the requirements of the system standard IEC 60601 1 1 The unit is for exclusive inter connection with IEC 60601 1 certified equipment in the patient environment and IEC 60XXX certified equipment outside of the patient environment If in doubt consult the technical services department or your local representative Caution Use suitable mounting apparatus to avoid risk of injury A Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked Hospital Only or Hospital Grade Use a power cord that matches the voltage of the power outlet which has been approved and comp
17. g the Power Cord 11 POC W181 User Manual 2 2 2 Connecting the Ground Pin Step 1 System ready Find the Equipotential Terminal on rear side of POC An Equipotential Terminal is provide to optionally connect to a hospital ground earth system Equipotential Terminal Figure 2 7 POC W181 Equipotential Terminal Pin Step 2 Prepare the Grounding cable and the other terminal link to hospital ground earth system 27 4 s Figure 2 8 Grounding Cable with Connector Step 3 Grounding cable plug with POC W181 Equipotential Terminal See Figure 2 8 POC W181 User Manual 12 2 2 3 Switch on the Power 2 3 2 4 Switch on the reset switch on the front cover See Figure 2 11 Figure 2 9 Press the Power Button to Boot System Running the BIOS Setup Program Your POC W181 has been properly set up and configured by your dealer prior to delivery You may still find it necessary to use the BIOS Basic Input Output System setup program to change system configuration information such as the current date and time or your type of hard drive The setup program is stored in read only mem ory It can be accessed either when you turn on or reset the panel PC by pressing the F2 or Del key on your keyboard immediately after powering on the computer The settings you specify with the setup program are recorded in a special area of memory called CMOS RAM This memor
18. hnician Please contact the ser vice technician or your retailer if you need this service Detailed operating procedures are specified in Appendix A CLASSIFICATION M Supply Class I adapter No applied part IPX1 Continuous Operation Not AP or APG category Warning This device is not suitable for use in the presence of flammable anes thetic mixtures with air oxygen nitrous oxide or for life support sys tems Maintenance To properly maintain and clean the surfaces use only the approved products or clean with a dry applicator Caution When servicing the device always use replacement parts that are quali fied to Advantech standards Advantech Medical cannot warrant or A endorse the safe performance of third party replacement parts for use with our medical devices Make sure the user does not allow contact between SIP SOPs and the patient at the same time POC W181 User Manual iv When networking with electrical devices the operator is responsible for ensuring that the resulting system meets the requirements set forth by the following standards EN 60601 1 IEC 60601 1 Medical electrical equipment Part 1 General requirements for safety EN 60601 1 1 IEC 60601 1 1 Medical electrical equipment Part 1 1 General requirements for safety Collateral standard Safety requirements for Medical electrical systems EN 60601 1 2 IEC 60601 1 2 Medical electrical equipment Part 1 2 General requirements for saf
19. in BIOS menu When you press F12 key in bootup BIOS will display a bootable device menu and you can select the proper boot device that you want BIOS Menu location BIOS Menu Boot Setup Popup Menu F12 BEnable Press F12 key at bootup displays popup menu Default Disable Press F12 key at bootup does not display popup menu 33 POC W181 User Manual AD ANTECH Enabling an Intelligent Planet www advantech com Please verify specifications before guoting This guide is intended for reference purposes only All product specifications are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2012
20. ion can prevent touching the LCD backlight button by mistake and adjusting the LCD backlight luminance BIOS Menu location BIOS Menu Advanced Embedded Controller Configuration Brightness But ton Control BEnable Front bezel LCD Backlight adjust button control function works Default BDisable Front bezel LCD Backlight adjust button control function does not work Volume Button Control You can enable disable Front volume button function in BIOS menu If you disable the Front volume button this button will not work So the user can not adjust speaker volume by this button This function prevents touching the front volume button by mistake and adjusting the speaker volume BIOS Menu location BIOS Menu Advanced Embedded Controller Configuration Volume Button Control BEnable Front bezel volume adjust button control function works Default Default Disable Front bezel volume adjust button control function does not work EC Beep Function You can enable disable EC beep function in BIOS menu If you disable the EC beep function EC will not generate beep sound when you press front bezel button POC W181 User Manual 32 BIOS Menu location BIOS Menu Advanced Embedded Controller Configuration EC Beep Func tion BEnable Beep sound when front bezel button pressed Default BDisable No beep sound when front bezel button pressed SETUP POPUP MENU F12 You can enable disable F12 key Setup popup menu
21. ivers for Windows 7 64 bit OS please visit and download from Advantech Support Portal 15 POC W181 User Manual 2 6 Troubleshooting When system runs abnormally such as 1 2 3 4 Fail to power on Fail to power off Power LED ON but no DC power output AC power in and all switches ON but system doesnt power on Contact your distributor sales representative or Advantech s customer service cen ter for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc A complete description of the problem The exact wording of any error messages Symptom photo or video if available POC W181 User Manual 16 Chapter 3 Driver Installation 3 1 Introduction The POC W181 supports one key driver installation User can click one button to install all drivers Warning Please use clean OS to perform this auto installation otherwise it might N cause un expect error 3 2 Automatic Driver Installation Windows XP 32 Bit Step 1 Double Click setup exe in DVD Drivers and Utilities POC181 XPP Onekey Installation The Install dialog will appear Step 2 Please follow the instruction to install drivers Windows XP 32 Bit Step 1 Double Click setup exe in DVD Drivers and Utilities
22. k of the POC W181 functions as a cooling surface that transfers heat from inside the computer to the cooler air outside Do not block this heatsink by any soft material Warning Your AC cord came equipped with a three wire grounding plug a plug that has a third grounding pin This plug will fit only a grounded AC out A let If you are unable to insert the plug into an outlet because the outlet is not grounded contact a licensed electrician to replace the outlet with a properly grounded outlet Do not defeat the purpose of the grounding plug Warning Never push objects of any kind into this product through the openings in the case Doing so may be dangerous and result in fire or a dangerous A electric shock Never place anything on the system case before turning off computer Never turn on your computer unless all of its internal and external parts are in place Operating the computer when it is open or missing parts can be danger ous and can damage your computer POC W181 User Manual 22 PCM 8712 Connector Map and Table 3 6 Fe Gi zi AD ANTECH CEX CN24 E SWI gondh 9 O L CN66 0 4 2 CN42 0000 neces O 0000 O O 0000 O J Bee
23. lies with the safety standard of your particular country V POC W181 User Manual Note Environmental Protection Follow national requirements to dispose of unit Explanation of Graphical Symbols IEC 60878 and ISO 3864 B 3 6 Warning dangerous voltage ISO 7000 0434 Caution consult ACCOMPANYING DOCUMENTS ISO 7000 1641 Follow operating instructions or consult instructions for use IEC 60417 5009 SANDY BY cEPP IEC 60417 5031 Direct current IEC 60417 5021 Equipotentiality Disposing of Old Products Within the European Union A EU wide legislation as implemented in each member state requires that waste electrical and electronic products carrying the mark shown on left must be disposed of separately from normal household waste This includes monitors and electrical accessories such as signal cables or power cords When you need to dispose of your display products please follow the guidance of your local authority or ask the shop where you purchased the product or if applicable follow any agreements made between yourself and the shop The mark on electrical and electronic products only applies to the current European Union member states POC W181 User Manual vi Guidance and manufacturer s declaration electromagnetic emissions Model POC W181 is intended for use in the electromagnetic environment specified below The customer or the user of the model POC W181 should
24. midity 10 95 40 C non condensing Environment 5 95 non condensing Storage 5 95 Transportation Shock Resistance 20G peak acceleration 11ms duration Pressure 700 1013 hPa Operation 375 mmHg to 760 mmHg Storage 375 mmHg to 760 mmHg Transportation Water Dust IPX1 compliant Resistance Dimensions 454 x 304 x56 mm 17 87 x 11 96 x 2 21 Physical WxHxD Characteristics Weight 5 8 kg Platform amp Utilities XP Professional Windows 7 SUSI 3 POC W181 User Manual Unit mm er 3 d en 56 r3 EA a H o 4 al 4 fn Y ET 454 v ui Le A ES 0 1 1 0 a E EH EC
25. n The setup program will guide you through preparation of your hard drive and installation of the operating system Installing the Drivers After installing your system software you will be able to set up the Chipset Graphics Ethernet audio and touchscreen functions by your own external DVD drive All the drivers except the DVD ROM drive driver are stored in a DVD disc entitled Drivers and Utilities The standard procedures for installing the drivers are described in Chapters 3 9 The various drivers and utilities in the DVD disc have their own text files which help users install the drivers and understand their functions These files are a very useful sup plement to the information in this manual For your reference the directory of drivers on the Drivers and Utilities DVD dAdriver folder Note drivers and utilities used for the POC W181 panel PCs are subject Ir to change without notice If in doubt check Advantech s website or con tact our application engineers for the latest information regarding drivers and utilities Windows XP Driver List These drivers located on driver DVD Drivers and Utilities 181 stallation folder Please follow sequence below to install driver Install Folder Name Note sequence 1 Chipset Please install chipset driver first 2 Graphics After graphics driver installation please install Microsoft NET Framework before reboot 3 DotNe
26. people Field strengths from fixed transmitters such as base stations for radio cellular cordless tele phones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the mea sured field strength in the location in which the model POC W181 is used exceeds the applica ble RF compliance level above the model POC W181 should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the model POC W181 b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m ix POC W181 User Manual FCC Class B This equipment has been tested and found to comply with the limits for a Class B dig ital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer ence when the equipment is operated in a residential environment This equipment generates uses and can radiate radio frequency energy If not installed and used in accordance with this user s manual it may cause harmful interference to radio com munications Note that even when this equipment is installed and used in accordance with this user s manual there is still no guarantee that interference
27. ping it or letting it fall may cause damage For plug in eguipment the power outlet socket must be located near the eguipment and must be easily accessible Caution To prevent overheating do not cover the openings and place the device in direct sunlight or near radiant heaters Make sure the voltage of the power source is correct before connecting the equip ment to the power outlet Position the power cord so that people cannot step on it Do iii POC W181 User Manual not place anything over the power cord If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient over voltage Caution Do not leave this equipment in an uncontrolled environment where the storage temperature is below 20 C 4 F or above 60 C 140 F this A may damage the equipment If your computer is noticeably losing time or the BIOS configuration resets to default the battery may not have power Caution Do not replace battery yourself Please contact a qualified technician or your retail A The computer is provided with a battery powered real time clock circuit There is a danger of explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacture Discard used batteries according to the manufacturer s instructions Improper installation of VESA mounting can result in serious personal injury VESA mount installation should be done by professional tec
28. rect functioning of the device may be compromised POC W181 User Manual x Additional Information and Assistance Contact your distributor sales representative or Advantech s customer service cen ter for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc B Acomplete description of the problem The exact wording of any error messages B This equipment is a source of electromagnetic waves Before use please make sure that there are not EMI sensitive devices in its surrounding which may mal function therefore Environmental Protection Follow national requirements to dispose of unit Contact Information Manufacturer Advantech Co Ltd No 1 Alley 20 Lane 26 Reuiguang Road Neihu District Taipei Taiwan 114 R O C TEL 02 27927818 Distributed in European by Advantech Europe GmbH Kolberger Strape 7 D 40599 Dusseldorf Germany Tel 49 211 97477350 Fax 49 211 97477300 Visit the Advantech websites at www advantech com or www advantech com tw if you need more information xi POC W181 User Manual POC W181 User Manual xii Contents Chapter Chapter Chapter Chapter Chapter Chapter 1 zz ox Ni 2 1 2 2 2 3 2 4 2 5 2 6 3 1 3 2 4 1 4 2 5 1 5
29. ry information Step 3 Click OK to close the successfully installation information window POC 127 User Manual 20 Operation and Safety information 5 1 5 2 General Safety Guide For your own safety and that of your equipment always take the following precau tions Disconnect the power plug by pulling the plug not the cord from your computer if any of the following conditions exists The power cord or plug becomes frayed or otherwise damaged You spill something into the case Your computer has been dropped or the case has been otherwise damaged You suspect that your computer needs service or repair You want to clean the computer or screen You want to remove install any parts Protecting Your Optical Drive To keep your optical drive working properly W Position your computer so that the drive tray doesn t bump into anything when it opens W Close the drive when you re not using it Do not put anything on the drive tray when it is open W Donottouch the optical drive lens with your fingers Do not wipe the lens with a paper towel or other abrasive surface Thermal The vent hole of the POC W181 rear cover functions as a cooling air flow inlet and outlet These air inlets and outlets transfer heat from inside the computer to the cooler air outside Do not block these holes vents by any soft material When using your POC W181 system it is normal for the rear metal heatsink to get warm The rear metal heatsin
30. support Intel AMT7 0 function Dual COM ports Quad USB 2 0 ports and a 24 bit stereo audio controller With a 2 5 SATA HDD drive optional the POC W181 is an user friendly computer For system integrators this highly integrated multimedia system lets you easily build a Point of Care Terminal into your applications The POC W181 makes it an ideal and safe point of care solution for patients and hospital practitioners The POC W181 is specially designed to resist spills and water damage and ensures dust resistance with its protected LCD and sealed ports The POC W181 is a reliable solution to your application s processing requirements Intended use The POC W181 is intended to serve as a Point of Care terminal POC for integration with hospital system POC W181 medical computing is designed for general purpose for hospital environment For data collection and dis play for reference It shall not be used as a life supporting system The latest version of user s manual is available to be downloaded from http support advantech com tw support 1 2 Specifications Chipset Intel QM67 CPU Intel Core i7 2610UE Processor 4M Cache 1 5GHz or Intel Core i3 2340UE Processor 3M Cache Computing 1 3GHz System Memory Up to 16GB DDR3 1333 MHz SDRAM Remark Due to standard PC architecture a cer tain amount of memory is reserved for system usage and therefore the actual memory size is less than the stated amount
31. t Dot Net Framework 3 5 LAN Onboard Ethernet Controller 5 Audio Realtek HD Audio POC W181 User Manual 14 6 AMT Intel Active Management Technology LAN1 7 Touch Please install internal resistive touch controller to USB 8 USB Please refer to Chapter 4 9 CardReader Optional Smart Card Reader 10 RFID Optional RFID Module 11 WLAN Optional Wireless LAN Card These Windows XP drivers are all for 32 bit version Windows 7 32 Bit Driver List Note a These drivers located on driver DVD Drivers and Utilities POC181 W7 Onekeyln stallation folder Please follow sequence below to install driver Install Folder Name Note sequence 1 Chipset Please install chipset driver first 2 Graphics After graphics driver installation please install Microsoft NET Framework before reboot 3 LAN Onboard Ethernet Controller 4 Audio Realtek HD Audio 5 AMT Intel Active Management Technology LAN1 6 Touch Please install internal resistive touch controller to USB 7 CardReader Optional Smart Card Reader 8 RFID Optional RFID Module 9 WLAN Optional Wireless LAN Card Note These Windows 7 drivers all 32 bit version D Note The drivers and utilities used for the POC W181 panel PCs are subject B to change without notice If in doubt check Advantechs website or con tact our application engineers for the latest information regarding drivers and utilities About dr
32. tic immunity Model POC W181 is intended for use in the electromagnetic environment specified below The customer or the user of the model POC W181 should assure that it is used in such an environ ment 60601 test Compliance Electromagnetic environment guid Immunity test level level ance Portable and mobile RF communica tions equipment should be used no closer to any part of the model POC W181 including cables than the recom mended separation distance calculated from the equation applicable to the fre quency of the transmitter Recommended separation distance 1 2 P 1 2 80 MHz to 800 MHz 3 Vrms d 22 34P 800 MHz to 2 5 GHz 61000 46 19092080 Sy 75 MHz where is the maximum output power rating of the transmitter in watts W according to the transmitter manufac 3 V m turer and d is the recommended separa Radiated RF 3 IEC 61000 4 3 en to 2 5 tion distance in meters m Field strengths from fixed RF transmit ters as determined by an electromag netic site survey should be less than the compliance level in each frequency range gt Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and
33. uld be at least 30 96 2 kV for power 2 kV for power supply lines supply lines Mains power quality should be that of a typical commercial or hospital environ 1 kV for input 1 kV forinput ment Electrical fast transient burst IEC 61000 4 4 output lines output lines 1 kV line s to 1 kV line s to Surge line s line s Mains power quality should be that of a typical commercial hospital environ 2 kV line s to 2 kV line s to ment earth earth lt 5 UT lt 5 UT gt 95 dip in UT gt 95 dip in UT for 0 5 cycle for 0 5 cycle Lu 0 i i 0 i variations on 90 ment If the user of the model POC for 5 cycles for 5 cycles power supply W181 requires continued operation dur input lines 6 8 ing power mains interruptions it is rec LM ommended that model POC W181 30 dip in UT 30 dip in UT 61000 4 be powered from an uninterruptible for 25 cycles for 25 cycles 11 power supply or a battery lt 5 UT lt 5 UT gt 95 dip in UT gt 95 dip in UT for 5 sec for 5 sec Power fre quency Power frequency magnetic fields should 50 60 Hz 3 Alm 3 Alm be at levels characteristic of a typical magnetic field location in a typical commercial or hos pital environment IEC 61000 4 8 NOTE UT is the A C mains voltage prior to application of the test level POC W181 User Manual viii Guidance and manufacturer s declaration electromagne
34. will not occur If this equip ment is believed to be causing harmful interference to radio or television reception this can be determined by turning the equipment on and off If interference is occur ring the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna B Increase the separation between the equipment and receiver u Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning Any changes or modifications made to the equipment which are not expressly approved by the relevant standards authority could void your A authority to operate the equipment List of Accessories Before installing your Point of Care Terminal ensure that the following materials have been received POC W181 series Point of Care Terminal B Accessories for POC W181 DVD disc Drivers User s manual and Utilities Mounting kits and packet of screws VESA mounting note x 1 China RoHs note x 1 Warning No user serviceable parts inside refer servicing to qualified personnel Only the accessories indicated on the list of accessories above have A been tested and approved to be used with the device Accordingly it is strongly recommended that only these accessories be used in conjunc tion with the specific device Otherwise the cor
35. y is backed up by a battery so that it will not be erased when you turn off or reset the system Whenever you turn on the power the system reads the settings stored in CMOS RAM and compares them to the equipment check conducted during the power on self test POST If an error occurs an error message will be displayed on screen and you will be prompted to run the setup program Installing System Software Recent releases of operating systems from major vendors include setup programs which load automatically and guide you through hard disk preparation and operating system installation The guidelines below will help you determine the steps necessary to install your operating system on the panel PC hard drive 13 POC W181 User Manual 2 5 Note Some distributors and system integrators may have already pre E installed system software prior to shipment of your panel If required insert your operating system s installation or setup diskette into the exter nal diskette drive until the release button pops out The BIOS supports system boot up directly from the CD ROM drive You may also insert your system installation CD ROM disk into your external CD ROM drive Power on or reset the system by pressing the F2 or Del keys The Point of Care Terminal will automatically load the operating system from the diskette or CD ROM If you are presented with the opening screen of a setup or installation program follow the instructions on scree
Download Pdf Manuals
Related Search
Related Contents
Istruzioni d`uso VEGABAR 51 MANUAL DO UTILIZADOR DE SOFTWARE Max Kn。bー0ch 取扱説明書 NEC PA272W-BK-SV Installation and Setup Guide Not for Reproduction article - Revue suisse de viticulture arboriculture Copyright © All rights reserved.
Failed to retrieve file