Home

DL1A and CBD4, CBD5, CBD6 systems

image

Contents

1. Page 20 of 24 DECLARATION OF CONFORMITY LINAK A S Smedeveenget 8 DK 6430 Nordborg hereby declares that LINAK Actuator System composed of Control Box s CBD4 CBD5 CBD6 And Linear Actuator s 31xxxH xxxxx50S DB4 DB5 DB6 DB7 DB9 DB14 DB16 and or Lifting Column s DL1A DL2 DL4 DL5 DL6 DL7 DL8 DL9 DL10 DL11 DL14 DL15 DL16 And Desk Panel s DP1C DP1K DPT DPB DPF DPBK DP1L DP1V DPA DPH WDPL1 and or Handset s HB2xxF2 00003 complies with the EMC Directive 2004 108 EC according to following standards EN 61000 6 1 2001 EN 61000 6 3 2001 EN 55022 1998 A2 Class B and complies with Low Voltage Directive 2006 95 EC according to the standard EN 60335 1 2002 A1 2004 A11 2004 A12 2006 A2 2006 A13 2008 and complies with Machinery Directive 2006 42 EC according to the standard EN 13849 1 2008 SRP CS Cat B PL b and SRESW PL b And Controls RF transmitter HB1XRFXXXX and or RF transmitter HB2XRFXXXX and or RF receiver RFRL complies with the Radio equipment and Telecommunications terminal equipment Directive 1999 5 EC EN 300220 2 2006 EN 61000 6 1 2007 EN 61000 6 3 2007 EN 60335 1 2002 A1 2004 A11 2004 A12 2006 A2 2006 A13 2008 EN 62311 2008 Nordborg 2011 05 25 Diu Chr LINAK A S John Kling B Sc E E Certification and Regulatory Affairs Authorized to compile the relevant technical documentation Original Declaration Page 21 of 24 LINAK APPLICATION POLICY
2. Moreover children must be under surveillance to ensure that they do not play with the product It is the operator s responsibility to ensure that there is tree space for the application to move without risk for the operator or bystanders before operating the application Misuse Do not overload the actuators this can cause danger of personal A injury and damage to the system Do not use the actuator system for lifting persons Do not sit or stand on a table while operating risk of personal injury Do not use the system in environments other than the intended indoor use Page 7 of 24 Repairs In order to avoid the risk of malfunction all DESKLINE repairs must only be carried out by authorised LINAK workshops or repairers as special tools must be used and special gaskets must be fitted Lifting units under warranty must also be returned to authorised LINAK workshops Warning If any of the DESKLINE products are opened there will be a risk of subsequent malfunction Warning The DESKLINE systems do not withstand cutting oil DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY LINAK A S Smedeveenget 8 DK 6430 Nordborg Name and address of the person authorized to compile the relevant technical documentation John Kling Group Headquarters Guderup DK 6430 Nordborg email jklI linak com Herewith declares that LINAK Actuators and Actuator Systems comply with the following parts of the Machinery Directiv
3. DLIA ciasssrenccivettnomnencisccnnnsxvenenedetelaeacsintaaditsieteasaseasnsveedusnd dasnnciiie eames 9 Mounting guidelines CBD4 CBD5 CBD6 cess tnndacceiacevedesnonsesanesbusedhineelacadetse vec deanunsaseodbracssenntansectesbedecdemencasse 11 Electrical connection of the DL1A SVSt6 i x cnnicciuacasatniaesetenoysscouseennbeenulsdadnasinieleaiiestanawsntacenudiomenseelcatidearss 12 Initialisation of the DESKLINE DL1A parallel systems 20 00 00 ceccccceceeeeeeeeeeceeeeeneeeeeeeeeeeeeceetsaseeeeeeeeeseeeeeneaees 13 Accessories and repair tiie etec dascessesiataseroncsateonpoulssies ends donssoansiaanioncustenbanuewexeeddudcenmnpiiatananstcccdemmabadeeemnvedddceeseneennes 14 Disposal of MIN TAN QCM products oaunuununuuunnunniuuiiiiiiiiiiiiiiiii kiitti 11111111111 EErEE EEEE EEEEE AEAEE EEEE EEEE EEEn E nnne E nnee nErenn 15 Labels ii cacsnnccasesdannecantnoandvaniassncesnesnindannaaveseslensdonsgheniias tea 11E EEE EEE EEEEEEEELEEELEEEELEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE PEERAA EEE EEEE 17 Drawing appendiX ae een ee meee ane Meee ee ee Cee aE re terete eee ee mere EEEE NEA EEE enn ee ee etre a 18 Addresses aes snd cs cece cece sc pcan en tee cece esas oes chiens ene cescours E E 24 Page 3 of 24 Preface We are delighted that you have chosen a product from LINAK A S LINAK systems are high tech products based on many years of experience in the manufacture and development of actuators electric control boxes controls and chargers
4. mail dkreh linak dk www linak pl REPUBLIC OF KOREA LINAK Korea Ltd Phone 82 0 2 6231 1515 Fax 82 0 2 6231 1516 E mail scully linak kr www linak kr RUSSIAN FEDERATION 000 LINAK Phone 7 495 280 14 26 Fax 7 495 687 14 26 E mail info linak ru www linak ru SPAIN LINAK Actuadores S L u Phone 34 93 588 27 77 Fax 34 93 588 27 85 E mail linakact linak es www linak es SWEDEN LINAK Scandinavia AB Phone 46 8 732 20 00 Fax 46 8 732 20 50 E mail info linak se www linak se SWITZERLAND LINAK AG Phone 41 43 388 31 88 Fax 41 43 388 31 87 E mail info linak ch www linak ch TAIWAN LINAK A S Taiwan Representative Office Phone 886 2 27290068 Fax 886 2 27290096 Mobile 886 989292100 E mail michael chen linak com tw www linak com tw TURKEY LINAK ith ihr San ve Tic A S Phone 90 312 4726338 Fax 90 312 4726635 E mail info linak com tr www linak com tr UNITED KINGDOM LINAK UK Limited Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail sales linak co uk www linak co uk Terms of use The user is responsible for determining the suitability of LINAK products for specific application LINAK takes great care in providing accurate and up to date information on its products However due to continuous development in order to improve its products LINAK products are subject to frequent modifications and changes without prior notice Therefore LINAK cannot guarante
5. 0 744615 E mail info linak de www linak at BELGIUM amp LUXEMBOURG LINAK Actuator Systems NV SA Phone 32 0 9 230 01 09 Fax 32 0 9 230 88 80 E mail info linak be www linak be BRAZIL LINAK Do Brasi Phone 55 11 2832 7070 Fax 55 11 2832 7060 E mail info linak com br www linak com br CANADA LINAK Canada Inc Phone 1 502 253 5595 Fax 1 416 255 7720 E mail info linak ca www linak us com CZECH REPUBLIC LINAK C amp S S R O Phone 420581741814 Fax 420581702452 E mail ponizil linak cz www linak cz DISTRIBUTORS ARGENTINA Novotec Argentina SRL Phone 54 11 4303 8900 54 11 4303 8989 Fax 54 11 4032 0184 E mail info novotecargentina com www novotecargentina com AUSTRALIA Ballarat Industrial Supplies www ballind com au BL Shipways amp Co www bishipway com au Gas Strut Marine and Industrial www gasstrutmarine com au Prime Motion amp Control www primehyd com au West Vic Industrial Supplies www westvicindustrial com au COLOMBIA MEM Ltda Phone 57 1 334 7666 Fax 57 1 282 1684 E mail servicioalcliente memltda com co www memltda com co INDONESIA Pt Himalaya Everest Jaya Phone 6 221 544 8956 6 221 544 8965 6 221 619 4658 6 221619 1925 E mail hejplastic div centrin net id www hej co id Fax Com rcio De Atuadores Ltda DENMARK LINAK A S Group Headquarters Guderup Phone 45 73 15 15 15 Fax 45 7
6. 4 45 80 48 Fax 45 73 15 16 13 Sales E mail info linak com www linak com DENMARK LINAK Danmark A S Phone 45 86 80 36 11 Fax 45 86 82 90 51 E mail linak linak silkeborg dk www linak dk FINLAND LINAK OY Phone 358 10 841 8700 Fax 358 10 841 8729 E mail linak linak fi www linak fi FRANCE LINAK France E U R L Phone 33 0 2 41 36 34 34 Fax 33 0 2 41 36 35 00 E mail linak linak fr www linak fr GERMANY LINAK GmbH Phone 49 6043 9655 0 Fax 49 6043 9655 60 E mail info linak de www linak de INDIA LINAK A S India Liaison Office Phone 91 120 4393335 Fax 91 120 4273708 E mail info linak in www linak in IRELAND LINAK UK Limited Ireland Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 44 0 796 855 1606 UK Mobile SLOVAKIA LINAK Slovakia s r o Phone 421 51 75 63 414 Fax 421 51 75 63 410 E mail jp linak sk www linak com ITALY LINAK Italia S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it JAPAN LINAK K K Phone 81 45 533 0802 Fax 81 45 533 0803 E mail linak linak jp www linak jp MALAYSIA LINAK Actuators Sdn Bhd Phone 60 4 210 6500 Fax 60 4 226 8901 E mail info linak asia com www linak my NETHERLANDS LINAK Actuator Systems B V Phone 31 76 5 42 44 40 Fax 31 76 5 42 61 10 E mail info linak nl www linak nl NEW ZEALAND LINAK New Zealand Ltd Phone 64 9580 2071 Fax 64 95
7. 80 2072 E mail nzsales linak com au www linak co nz 35 387 634 6554 Republic Of Ireland Mobile E mail sales linak co uk www linak co uk IRAN Bod Inc Phone 98 2188998635 6 Fax 98 2188954481 E mail info bod ir www bod ir PERU Percy Martin Del Aguila Ubillus Phone 51 99 883 9879 RUSSIAN FEDERATION 000 FAM Phone 7 812 3319333 Fax 7 812 3271454 E mail purchase fam drive ru www fam drive ru SINGAPORE Servo Dynamics Pte Ltd Phone 65 6844 0288 Fax 65 6844 0070 E mail servodynamics servo com sg www servo com sg SOUTH AFRICA Industrial Specialised Applications CC For contact details on other countries please visit www linak com or contact LINAK INTERNATIONAL Phone 45 73 15 15 15 Fax 45 74 45 90 10 Fax 45 73 15 16 13 Sales E mail info linak com www linak com Phone 27 11 312 2292 or 27 11 2077600 Switch Board Fax 27 11315 6999 E mail gartht isagroup co za www isaza co za UNITED ARAB EMIRATES Mechatronics Phone 971 4 267 4311 Fax 971 4 267 4312 E mail mechtron emirates net ae www mechatronics ae Page 24 of 24 USA LINAK U S Inc North and South American Headquarters Phone 1 502 253 5595 Fax 1 502 253 5596 E mail info linak us com www linak us com NORWAY LINAK Norge AS Phone 47 32 82 90 90 Fax 47 32 82 90 98 E mail info linak no www linak no POLAND LINAK Polska Phone 48 22 500 28 74 Fax 48 22 500 28 75 E
8. DESKLINE IMPROVING ERGONOMICS DL1A and CBD4 CBD5 CBD6 systems WE IMPROVE YOUR LIFE Page 2 of 24 Contents Preface oe reenn e eneret aert EEE EEE EERE EERE EERE EEE EEE EEE EEE OIL OL Lo oii EEEE EEEn E nnana 4 Important information eee men ease ene eme ent mnnnnte St Sean e een srr rime tener 1 1111 EEEE EE Aannite reeen eet nn te rene eter emer Tr ne 5 Safety INsStrUctiO NS re cee crete peso nese sseesg cianitbbunnmstuedrencopecesemesstivseestiepnouiaash ecole evenancayeseesseaeeeaeapacemeeaecntcemescpaeyees 5 Before installation re installation or troubleshooting 0 cece cc cece cee eeeee cece eeeeeeeeeeeeeaaeeeeeeeeeeeeeeeeaes 5 Before Start Up 2 0 0 0 LIL ELI ELL LOLI O LOLI OUI I SUI oii nnn inna eaaaaaaaaaaeaeaaaaaaaawaaawees 5 D ring Operati m eroi Re ctee i reatn Meese ee Ment Mere E E E cre eter ere ee errr eer ae nie eee rrr Te er 6 FR US erecta cs pene ence cece ee een ce dem enececte E E 6 Manufacturer s declaration isa scsctisiccieccsnssscxcsadeeeeenieee sie eeeenanne eset se ewes ke sda eae 6 Misc on the DESKLINE DL1A system 0 000000 cccccccccccee cece cece ee cee tee eeeeeeeeeeeceteeeeeeeeeeeeeecsteetnteeeeeeseeeesenneeaes 7 Warranty cage aeons ee ec E E eee 7 Maintenance e a EE ee E E eee deromsecopeeees 7 Description of the DESKLINE DL1A System o 2c cece cece tiin eee ee ttit EEEE teas aeeeeeeeeeeeeeeeeeeeeeeeseeeeeensieaes 8 Mounting guidelines for the DESKLINE
9. E BY LINAK A S DENMARK Label for CBD4 LINK 0w WE IMPROVE YOUR LIFE i DESIGNED IN DENMARK item CBDSP00020A 109 Date YYYY MM DD Ulin 120V 60 Hz re Pin 400W U Out 12 24 V KAJ File Etsites Op 10 Max 2 min 18 min S W P N 0077432 Ver 1 22 OPODASKEE DOUBLE INSULATED WHEN SERVISING USE ONLY IDENTICAL REPLACEMENT PARTS NOT TO OPENED BY UNAUTHORIZED PERSONNEL LINAK G U Out 12 24 V Op 10 Max 2 min 18 min CHOOASES CAUTION WE IMPROVE YOUR LIFE DESIGNED IN DENMARK Item CBD4P00020A4 009 Date YYYY MM DD Uin 230V 50Hz Pin 400W S W PIN 0077432 Ver 1 22 DOUBLE INSULATED WHEN SERVISING USE ONLY IDENTICAL REPLACEMENT PARTS NOT TO OPENED BY UNAUTHORIZED PERSONNEL P O xxxxxx ASSEMBLED IN XX YY P O xooxxxx Label for CBD5 Label for CBD6 Page 18 of 24 DRAWING APPENDIX DL1A lifting unit LINAK A S DL1001A CBD4 Page 19 of 24 CBD5 CBD6
10. The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware software technical advice etc related to an existing or new customer application LINAK products as defined above are applicable for a wide range of applications within the Medical Furniture Desk and Industry areas Yet LINAK cannot know all the conditions under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humidity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK product LINAK shall be responsible solely that the LINAK products comply with the specifications set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specific LINAK product can be used for the application in question Page 22 of 24 Page 23 of 24 FACTORIES CHINA LINAK Shenzhen Actuator Systems Ltd Phone 86 755 8610 6656 Fax 86 755 8610 6990 E mail sales linak cn www linak cn SUBSIDIARIES AUSTRALIA LINAK Australia Pty Ltd Phone 61 3 8796 9777 Fax 61 3 8796 9778 E mail sales linak com au www linak com au AUSTRIA LINAK Reprasentanz Osterreich Wien Phone 43 1 890 7446 Fax 43 1 89
11. We are also constantly improving our products to meet customer requirements This User Manual will tell you how to install use and maintain your LINAK DESKLINE products We are sure that the DESKLINE products will give you many years of problem free operation Before our products leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your systems you are always welcome to contact our service departments or service centres LINAK subsidiaries and distributors all over the world have authorised service centres which are always ready to help you LINAK provides a warranty on all its products This warranty however is subject to correct use in accordance with the specifications maintenance being done correctly and any repairs being carried out at a service centre which is authorised to repair LINAK products Changes in installation and use of LINAK systems can affect their operation and durability Changes must therefore only be made by agreement with LINAK A S and are made at your own risk LINAK A S Page 4 of 24 Important information Important information on LINAK products can be found under the following headings A Warning Failure to comply with these instructions may result in accidents involving serious personal injury ud Failing to follow these instructions can result in the product being D damaged or being destroyed Safety instruction AN General Sa
12. be disconnected at replacement if any The mounting screws on the control box must be fastened with a max torque of 1 Nm The mounting surface to which the control box is attached should have a surface evenness of better than 0 5 mm CBD6 bottom with cable grooves The bottom of CBD6 is equipped with two cable grooves improving the cable management when mounting The grooves can be used to bypass the CBD for both motorcables and the mains cable EU version only from one side to the other giving a cleaner design all No Remember to lead the cables through the grooves before mounting the control box For mounting and operation of the desk panel please see the separate user manual for desk panels Page 13 of 24 Electrical connection of the DL1A system The DESKLINE DL5 DL6 system is to be connected as shown on figure 4 Each DL5 DL6 Is to be connected to the sockets on the control box by means of the motor cables which have an 6 pin plug in each end Finally the mains cable is to be mounted and power switched on t3 Please note that the control box must only be connected to the voltage stated on the label CBD4 CBD5 CBD6 with earth The CBD4 CBD5 CBD6 earth cable to be mounted on the desk construction typically the top frame in a way that ensures good electrical contact The function of the earth cable is to earth the desk and ground static electricity The earth connection does not protect other electri
13. cal products If the power cable is damaged it has to be replaced by an authorized LINAK service centre to avoid f CBD4 CBD5 with mains cut off non ZERO models any danger DL1A cable Hook for cable relief Mains cable DL1A Figure 7 Page 14 of 24 Initialisation of the DESKLINE DL1A parallel systems To obtain parallel operation of a DESKLINE system it is necessary that the system at first activation drives the lifting units DL1 in end stop position bottom Thus the control box registers the bottom position for each lifting unit If an extra actuator apart from the DL1 is connected to the system this actuator must also be initialised Drive the actuator to inner posistion and then to outer position Besides the system has to be initialised when exchanging the lifting units or the control box Page 15 of 24 Accessories and repair Ordering accessories Order from your nearest LINAK dealer or subsidiary Accessories Please contact your nearest LINAK dealer for information Repairs Systems should only be repaired by an authorised LINAK service centre or engineer Systems to be repaired under warranty must be sent to an authorised LINAK service centre Warning By unauthorised opening of the system there is a risk that it may malfunction at a later date Spare parts Please contact your nearest LINAK dealer for information on spare parts Page 16 of 24 Disposal of LINAK s products As LINAK s customers of
14. e 2006 42 EC ANNEX Essential health and safety requirements relating to the design and construction of machinery 1 5 1 Electricity supply Directive 2006 95 EC on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 1 5 10 Radiation 1 5 11 External radiation Directive 2004 108 EC on the approximation of the laws of the Member States relating to electromagnetic compatibility The relevant technical documentation is compiled in accordance with part B of Annex VII and that this documentation or part hereof will be transmitted by post or electronically to a reasoned request by the national authorities This partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of this Directive where appropriate Date 2010 01 01 Signature John Kling Certification and Regulatory Affairs Page 8 of 24 Misc on the DESKLINE DL1A system This system is a DESKLINE system developed for desks and for indoor use in offices Do not use it in industrial kitchens or in other enviroments that have to be cleaned with aggressive detergents Do not bolt the legs to the floor so that free movement is prevented This could cause serious damage to the legs in fault situations Warranty There is a 36 months warranty on the DESKLINE products against manufacturing faults fro
15. e the correct and actual status of said information on its products While LINAK uses its best efforts to fulfil orders LINAK cannot for the same reasons as mentioned above guarantee the availability of any particular product Therefore LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK All sales are subject to the Standard Terms of Sale and Delivery for LINAK For a copy hereof please contact LINAK LINAK amp WE IMPROVE YOUR LIFE LINAK AVS reserve the right to make technical alterations Copyright LINAK 2013 03 MA M9 02 408 C
16. eduction of the life of the system Maximum load for each DL1A 1600 N Maximum load for a system with CBD4 400 W 3200 N Maximum load for a system with CBD4 600 W 4800 N Maximum load for a system with CBD5 500 W 3200 N Maximum load for a system with CBD6 375 W 2400 N Page 10 of 24 Mounting guidelines for the DESKLINE DL1A The lifting units are normally mounted with the motor housings upwards and pointing towards each AN other see figure 2 The aluminium motor housing is supplied with 6 pcs of M6 threaded holes meant for mounting on the desk frame The threaded holes are rolled into the aluminium housing 6 x M6 Max thrust moment 7 5 Nm Figure 1 A It is recommended to use all 6 M6 threaded holes As the tabletop amplifies the sound we advise you 13 to place a vibration shockabsorbing material between the tabletop and the table frame V ZZZ 2 Absorbing material tion Min desk height Height of the DL1 in the lowest pos fe Floor level Figure 2 A suitable desk height in the lowest position can be obtained by mounting the lifting unit on a 6 8 mm bottom plate by means of 4 pcs of M6 countersinked screws We recommend you to use screws of min quality 8 8 The thrust moment must not exceed 10 Nm in the bottom plate thread Page 11 of 24 Mounting bracket Cross bar Figure 3 Example of how to mount a 2 parallel DESKLINE DL1A system for the mounting bracket and the su
17. fe use of the system is possible only when the operating instructions are read completely and the instructions contained are strictly observed Failure to comply with instructions marked with the NOTE symbol may result in serious damage to the system or one of its components It is important for everyone who is to connect install or use the A systems to have the necessary information and access to this User Manual Follow the instructions for mounting risk of injury if these instructions are not followed A The appliance is not intended for use by young children or infirm persons without supervision AN If there is visible damage on the product it must not be installed N Note that during construction of applications in which the actuator is to be fitted there must be no possibility of personal injury for example the squeezing of fingers or arms net Assure free space for movement of application in both directions to 7 avoid blockade Page 5 of 24 Before installation re installation or troubleshooting e Stop the DL1A e Switch off the power supply and pull out the mains plug e Relieve the DL1A of any loads which may be released during the work Before start up e Make sure that the system has been installed as instructed in this User Manual e Make sure that the voltage of the control box is correct before the system is connected to the mains e System connection The individual parts must be connected befo
18. ic recycling or combustin DLIA X CBD4 CBD5 CBD6 X DPXX X Comments Disposal of batteries Details regarding safe disposal of used and leaking batteries Batteries should be disposed in accordance with appropriate federal state and local regulations LINAK recommends that used or leaking batteries are disposed through local recycling system Please do not throw used or leaking batteries in normal household waste or in nature This will cause damage to the enviroment How to deal with leaking batteries Leaking batteries should be disposed as described above If leaking batteries are discovered in the product the batteries must be removed at once to minimise damage to the product If leaking batteries are left in the product it might become defect It is recommended to use plastic gloves when handeling leaking batteries The contents of a leaking batteries can cause chemical burns and respiratory irritation If exposed to the contents of a leaking battery please wash with soap and water If irritation persists please seek medical attention In case of eye contact please flush eyes thoroughly with water for 15 minutes and seek medical attention Page 17 of 24 Label for DL1A DENMARK Item No DL1A501A00500645 Prod Date 2011 05 13 Max Load 1600 N Power Rate 18 V Max 10 Amp Duty Cycle 10 Max 2 min 18 min NOT TO BE OPENED BY UNAUTHORIZED PERSONNEL N COR P O MAD
19. m the production date of the individual products see label LINAK A S warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with Furthermore the system must not be exposed to violent treatment In the event of this the warranty will be ineffective invalid For further details please see LINAK A S ordinary conditions of sale Maintenance Clean dust and dirt on the outside of the system at appropriate intervals and inspect them for damage and breaks Inspect the connections cables and plugs and check for correct functioning as well as fixing points Service of double insulated products Class Il A Class Il or double insulated electrical appliance is one which has been designed in such a way that it does not require a safety connection to electrical earth US ground The basic requirement is that no single failure can result in dangerous voltage becoming exposed so that it might cause an electric shock and that this is achieved without relying on an earthed metal casing This is usually achieved at least in part by having two layers of insulating material surrounding live parts or by using reinforced insulation There is no earthing grounding means provided on the product and no earthing grounding means is to be added to the product In Europe a double insulated appliance must be labelled Class insulation symbol a square inside another square Servicing a double i
20. nsulated product requires extreme care and knowledge of the system and is to be done only by qualified service personnel Replacement parts for a double insulated product must be identical to the parts they replace W H 1 double insulated or bear the double Wg The cleaners and disinfectants must not be highly alkaline or acidic pH value 6 8 Page 9 of 24 Description of the DESKLINE DL1A system Each DESKLINE DL1A actuator is equipped with a motor and parallel memory drive is ensured by means of software in the CBD4 CBD5 CBD6 that also takes account of oblique load on the desk Soft start and stop are also part of this software which ensures a soft start and stop when adjusting the desk The DESKLINE DL1A system range contains the following products e 1 control box CBD4 CBD5 CBD6 1 single DL1A or 2 3 or 4 parallel 1 exchangeable mains cable 1 2 3 or 4 motor cables 1 DP1U DPF1M if memory function is required DP1C WDPL DPT DPF1C if memory function and display is required or 1 DPA DPB DP1K DP1V DPF1K if only up down Is required Options e Possibility of running extra actuators LA31 with hall Application of the DESKLINE DL1A system Irrespective of the load the duty cycle 10 6 min hour or max 2 min at continuous use stated in the data sheets must NOT be exceeded as this will result in a superheating of the motor the brake and the spindle nut Exceeding the duty cycle will result in a dramatic r
21. re the control box is connected to the mains See the User Manual for LINAK actuators If necessary During operation e f the control box makes unusual noises or smells switch off the mains voltage immediately e Take care that the cables are not damaged e Unplug the mains cable on mobile equipment before it is moved e The products must only be used in an environment that corresponds to their IP protection Misc The actuator system has a sound level below 55dB A in typical applications Updated manuals and declarations can always be found here www linak com deskline Page 6 of 24 Only for EU markets This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have given Supervision or instruction concerning use of the appliance in a sate way and understand the hazards Involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Only for Non EU markets Persons who do not have the necessary experience or knowledge of the product products must not use the product products Besides persons with reduced physical sensory or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons
22. rface of the lifting unit see figure 1 The use of any longer screws will come into contact with the inner parts This will result in an irregular operation or even damage the lifting unit To avoid damage of the lifting unit there must be min 1 mm space between the end of the screw ll fie The DESKLINE DL1A system can only be used in push applications with the motor housing mounted upwards D Placement of a monitor directly above the motor housing may cause malfunction of the monitor TE Magnets inside the motor may interrupt the picture on the monitor depending on the distance and type of monitor If this is the case the problem may be solved by placing an iron plate tube or another magnetic material somewhat larger than the motor housing between the motor and the tabletop Page 12 of 24 Mounting guidelines CBD4 CBD5 CBD6 The control box is to be fastened with 4 screws 3 screws for CBD5 and CBD6 with a head diameter between 8and 10mm Out of regard for the tension surface 10 mm is preferable See drawing appendix for placing of mounting holes and the space the CBD takes up CBD4 Control box CBD5 Control box CBD6 Control box The CBD must not be packed in heat insulating material but must be placed so that it can emit waste heat into the surroundings There are no ventilation holes to consider the CBD emits heat through the surface The plug must be visible when the CBD is mounted so that the supply to the CBD can
23. ten ask us how our products can be disposed or scrapped we have prepared this guidance that enables a classification to different waste fractions for recycling or combustion Guidance We recommend our products to be disassembled as much as possible and divided into different waste groups for recycling or combustion For example waste can be sorted into metals plastics cable scrap combustible material and recoverable resources Some of these main groups can be further divided into subgroups e g metal can be divided into steel aluminium copper and plastic can be divided into ABS PA PE PP As an example the table below breaks down the different components in LINAK products to various recycling groups Product Components Recycling group Columns Actuator Spindle and motor Plastic housing Scrap Plastic recycling or combustion Cable PCB board Cable Cable scrap or combustion PCB boards Electronics scrap Control Box PCB boards Electronics scrap Plastic housing Plastic recycling or combustion Cable Cable scrap or combustion Transformer Metal scrap Handset Control Plastic housing Plastic recycling or combustion Cable scrap or combustion Electronics scrap By now almost all our casted plastic parts are supplied with an interior code for plastic type and fibre contents if any Main groups of disposal Product main groups Metal scrap Cable scrap Electronics scrap Plast

Download Pdf Manuals