1. Q 4 PAURAGE RE NEE 5 6 APPLICATION DIAGRAM 00 0 cece eee eee eee nee eee t ee eaaees 7 PARTS amp FUNCTIONS COLOR IR CAMERA OUTDOOR STATION nsaisan 1 9 PARTS amp FUNCTIONS COLOR MONITOR INSIDE STATION 10 11 PARTS amp FUNCTIONS AUDIO PHONE SET sesssssmmmIee 11 WIRING CONNECTION SYSTEM DIAGRAM sme 12 INSTALLATION 1 14 OPERATION T 15 17 CODE ACCESS e RK EE 18 19 SPECIFIOSTIONS ee 19 20 LIMITED WARRANTY GE 20 9 Ni LEE 21 KEE RO BUC EE 21 23 3 24 SERIES FEATURES Color IR Camera Outdoor Stations NC DS2 1 3 CCD 420 TVL 0 05 Lux 120 sec Communication Duration Duplex Communication Type Recessed Mounting IP55 Rating 12V 14 5V DC 200mA 5 91 x 9 06 x 1 69 175mm x 230mm x 43mm NC DS2 SLIM 1 3 CCD 420 TVL 0 05 Lux 3 6mm Lens Hands free Talking 120 sec Communication Duration Duplex Communication Type Surface Mounting IP55 Rating 12V 14 5V DC 100mA 2 17 x 5 12 x 1 54 55mm x 130mm x 39mm Color Monitor Inside Stations NC MON4 Main 7 Screen 2 min Talking Time Dual Transmission Mode Surface Mounting 12V 14 5V DC 800mA 50 60Hz Stand by 50mA 9 45 x 6 89 x 1 5 240mm x 175mm x 38mm Inside Audio Station NC APS Surface Mounting 12V 14 5V DC 3 0 x 9 06 x 2 31 76mm x 230mm x 58mm NC DS2 ST 1 3 CCD 420 TVL
2. NC MON4 amp NC MON4 SUB Hole Plastic 145cm Hamulus Instructions 1 System Cable Non STP core cable wire gt 0 5mm from Outdoor Station to the farthest monitor 200ft 70m 2 Each monitor should be paralleled One Main monitor can extend up to 3 Sub monitors One Main monitor can connect to a maximum of 2 Outdoor Stations 3 The handset monitor only has 2 function buttons 4 Each Video Door Phone is 12V DC 14 5V DC 1 3A 14 NC MON4 SUB N CN4 CN3 DIAG M DI SNO Connected Connected with last with next indoor monitor extension indoor monitor l red 2 blue 3 yellow 4 white 5 red 6 black 1 AUDIO 2 GND 3 V 4 VIDEO 5 POWER 6 POWER GND AUDIO PHONE SET PARTS amp FUNCTIONS NC APS CC S LL red 2 blue 4 3 yellow 4 white Calling 8 Connected with D the CN3 of master indoor monitor WIRING CONNECTION SYSTEM DIAGRAM Sub 1 Sub 2 Sub 3 EEN i Boorkoek po mc EET H 1 RE EE 1 RE OF 1 RE i o 2 BL I 2 BL i 2 BL 04 3 YE 1 o m 3 YE 04 r 3 YE 1 64 4 WH Io A WH 9j L WH l je CN3 CN3 CN3 PE o Lo To L r O i oO 2 CN4 CNA i s i i i Extension Unit 2 Extension Unit 3 Audio Phone Set 1 o e e e 1 oa i e a o l e i ital i T VG i oe Audio Pf ne Set 2 9000 Power Supply 2000 Power Supply 1 pou Voice 1234 for Lock 4321 for Lock 2 Blue Grou
3. 3 Hangot 9 Brightness 4 a DoorLock Releasing 10 Chrome Contrast m 1 SmemTemma 5 4 Taking e moer w Gm NC MONA Main Ka N Connected I J3 Connected with with extension LI J1 outdoor station2 indoor monitor A m d Cu Short circuitJ3 BIEN CN CNA Night light of outdoor station CNI CN3 Short circuitJ1 Ringing output TT T ILI Short circuitJ2 Connected with Connected Coax outdoor stationl with audio l red 2 blue 3 yellow 4 white 5 red 6 black 1 AUDIO 2 GND 3 V 4 VIDEO 5 POWER 6 POWER GND 10 OPERATION 1 Visitor Call The visitor press The visitor press A view of the front door can be seen thecall e thecall anytime the entrance button is pressed button on Ky button on and a dialogue can be made with anyone outdoor lir outdoor cj tthe front door gtation 1 gtation 2 F at the ITO oor achime wr a W achime The visitor image appears on the monitor LU pe l ue i fA Dialogue begins f a i sei Dialogue duration as Is up to 120 C d i seconds at a time Tocheck W y Openthedoor Door release function l o operates but when the i visitor s image Is still pil displayed on the screen SEN Lech Press the TALKING button T 1 or hang up the handset J p Ends the call NC DS2 KP Screws Al Water cover UI Te RK ba B Gu e det fom Oei EI
4. SENTRY 4T www SentryUS com FARFID www ZRFID com Additional Technology Security Inc dba Sentry US 5500 Stewart Avenue Fremont CA 94538 E mail info SentryUS com Tel 1 800 916 8783 International 510 279 9992 ZRFID is an affiliate of Sentry US Specialized in Access Control Products Copyright 2010 2012 24 R201205 V02 SENTRYAED Operation amp Installation Manual Color IR Camera amp Video Intercom System 24 Series Camera Video 2 NC MON4 NC APS gt NC DS2 NC MON4 NC DS2 ST Main SUB NC DS2 SLIM NC DS2 KP Camera Color IR Camera Outdoor Stations Max 2 Standard Slim Type With Keypad NC DS2 NC DS2 ST NC DS2 SLIM NC DS2 KP 5911W x906 H XL69 D 354 Wo6 21H L69 D 2 1 1Wp612 H 1541D 2 Wx7 48 H xL 77D Recessed Surface Surface Surface Color Monitor Inside Stations Video Video Audio Inside Inside Main Monitor Sub Monitor Audio Phone Set NC MON4 NC MON4 SUB NC APS 9 45 W x 689 1H x 15D 9 45 tW x 6 89 1H x 15D 3 0 W x 9 06 H x 2 31 D Surface Surface Surface FC CE RoHS R201205 V02 Copyright 2010 2012 All rights reserved www sentryUS com AN Please read the Manual before attempting to use this product CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT OPEN COVERS OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL W Disposal of Old Electrical amp
5. 4 Objects and liquid entry Never push objects of any kind into this product as this may touch dangerous voltage points of short out parts that could result in a fire or electric shock Never spill any kind of liquid on the indoor products 5 Servicing Do not attempt to service this product by yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all service to qualified servicing personnel 24 SERIES FEATURES Color IR Camera Outdoor Stations NC DS2 e 1 3 CCD 420 TVL 0 05 Lux 120 sec Communication Duration Duplex Communication Type Recessed Mounting IP55 Rating 12V 14 5V DC 200mA 5 91 x 9 06 x 1 69 175mm x 230mm x 43mm NC DS2 SLIM 1 3 CCD 420 TVL 0 05 Lux 3 6mm Lens Hands free Talking 120 sec Communication Duration Duplex Communication Type Surface Mounting IP55 Rating 12V 14 5V DC 100mA 2 17 x 5 12 x 1 54 55mm x 130mm x 39mm Color Monitor Inside Stations NC MON4 Main 7 Screen 2 min Talking Time Dual Transmission Mode Surface Mounting 12V 14 5V DC 800mA 50 60Hz Stand by 50mA 9 45 x 6 89 x 1 5 240mm x 175mm x 38mm Inside Audio Station NC APS Surface Mounting 12V 14 5V DC 3 0 x 9 06 x 2 31 76mm x 230mm x 58mm NC DS2 ST 1 3 CCD 420 TVL 0 05 Lux 3 6mm Lens Hands free Talking 120 sec Communication Duration Duplex Communication Type Surface Mounting IP55 Rating 12V 14 5V DC 100mA 3 54
6. 0 05 Lux 3 6mm Lens Hands free Talking 120 sec Communication Duration Duplex Communication Type Surface Mounting IP55 Rating 12V 14 5V DC 100mA 3 54 x 5 12 x 1 69 90mm x 130mm x 43mm NC DS2 KP code only 1 3 CCD 420 TVL 0 05 Lux 3 6mm Lens Hands free Talking 120 sec Communication Duration Duplex Communication Type Personal Password Door Release Surface Mounting IP55 Rating 12V 14 5V DC 100mA 2 95 x 7 48 x 1 77 75mm x 190mm x 45mm NC MON4 SUB T Screen 2 min Talking Time Dual Transmission Mode Surface Mounting 12V 14 5V DC 700mA 50 60Hz Stand by 70mA 9 45 x 6 89 x 1 5 240mm x 175mm x 38mm OPTIONS A Electric Door Strikes for Metal Door P kl D 3 5 e i h e Jaw Strength 2000 Ibs e e 12V DC B Electric Door Strikes for Wood Door O i e Jaw Strength 2000 Ibs oi e 12V DC C Buzzer Buzzer Connection 1 Connect the buzzer positive to AP lock strike positive 2 Connect the buzzer negative to i e 5 14V DC power negative RELATED PRODUCTS from www ZRFID com Stand Alone Access Control Keypads Stand Alone Access Control Keypads w Built in EM 125KHz Reader ACSK EM Outdoor IP 65 12V 15V DC m 11 6cm 4 Stand Alone Access Control Slim Type Keypad w Built in EM 125KHz Reader ACS45K EM Outdoor IP 65 12V 15V DC 21 7 COLOR MONITOR INSIDE STATION PACKAGE CONTENTS Model NC M
7. 1 year period the product is returned prepaid with proof of purchase date and a description of the problem This warrant excludes and there is disclaimed liability for labor for removal of this product or reinstallation This warranty is void if this product is installed improperly or in an improper environment overloaded misused opened abused or altered in any manner or is not used under normal operating conditions or not in accordance with any labels or instructions There are no other implied warranties of any kind including merchantability and fitness or a particular purpose but if any implied warranty is required by the applicable jurisdiction the duration of any such implied warrant including merchantability and fitness of or a particular purpose is limited to one 1 year Manufacturer is not liable for incidental indirect special or consequential damages including without limitation damage to or loss of use of any equipment loss sales or profits or delay or failure to perform this warranty obligation The remedies provided therein are the exclusive remedies under this warranty whether based on contract tort or otherwise nm 20 5 NC MON4 Delete All Settings e One 1 NC MON4 1 Enter programming mode o One 1 Metal Mounting Bracket 2 Press the button and the unit will beep two Di Di sounds as a reminder men o Two 2 Short Mounting Screws 3 Press the button again and two additional beeps will s
8. Capture the image to send to the monitor 4 Speaker Sound from the monitor is delivered Call the indoor phone to communicate Calling Button Delivers and sound voice when communication Microphone l with the indoor phone T 8 Name Plate Show residential name 9 Connection Wiring Connection with the monitor NC DS2 NC DS2 SLIM 90 Indoormonitor 1 red 2 blue 3 yellow 4 white 5 black Indoormonitor 1 red 2 blue 3 Communication Among The Optional Monitors amp Audio li Call from the master monitor S j A beepwill Pressthe be heard call button Gp The Dialogue fromthe ny p begins master 5 W Call to master monitor from the audio Pick up the Pressagainthe handset and ES talking button pressthe i J gt TheDislogue We fromte ep call master Fy begins masterto ff li Conversation among the monitors and outdoor station A visitor calls d SOM Remus SE Adi Q p from all of the p The Dialogue gt s monitor and begins Afh audio eg gf can be performed if the monitor or audio are in talking status at the same m time U gt o Press the TALKING T Open the door gt button or hang up thehandset v End the dialogue Dialogue among the monitors outdoor stations and audio is possible only when the image of the visitor is displayed on the moni
9. Electronic Equipment Applicable in the European Union and other European countries with separate collection EN systems This symbol on the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product CAUTION 1 Handle this product with care Avoid any shock or bumping of the product Improper handling could damage the product 2 Requires a proper operating environment The main and sub monitors are designed for indoor use The allowable temperature range for operation of this product is between 14 F 131 F 10 C 55 C The camera outdoor stations are designed for outdoor use The allowable temperature range for operation of this product is between 4 F 131 F 20 C 55 C 3 Check the power source voltage The power source voltage should be within the specified range Product must meet the specifications
10. ON4 NC MON4 SUB Foi ij SE Voltage 12V 14 5V DC 50 60Hz we Ditonenee o One 1 Flush Mounting Back Cover o Four 4 Long Mounting Screws o One 1 Allen Wrench o One 1 Manual Working Current 800mA TalkTime Time amin amin LN 14 F 131 F 10 C 55 C NC DS2 ST One 1 NC DS2 ST Mounting Type o Three 3 Short Mounting Screws cim o Three 3 Wall Anchors 9 45 x 6 89 x 1 5 240mm x 175mm x 38mm xin o One 1 Allen Wrench rr H 7 o One 1 Manual Specifications are subject to change without notice AUDIO PHONE SET Voltage 12V 14 5V DC NC DS2 SLIM Stand by 70mA Working Current 100mA NC DS2 KP e One 1 NC DS2 KP o Three 3 Short Mounting Screws o Three 3 Wall Anchors uu o One 1 Allen Wrench fiel o One 1 Manual e One 1 NC DS2 SLIM o Two 2 Short Mounting Screws o Two 2 Wall Anchors o One 1 Manual 3 0 x 9 06 x 2 31 76 x 230 x 58 mm Specifications are subject to change without notice LIMITED WARRANTY LIMITED ONE 1 YEAR WARRANTY AND EXCLUSIONS Manufacturer warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Manufacturer is free of defects in materials and workmanship under normal and proper use for one 1 year from the purchase date Manufacturer s only obligation is to correct such defects by repair or replacement at its option if within such one
11. ed 3 Input the 4 digit code If the unit beeps two sounds it is unsuccessful If it beeps three sounds then the User Code is successfully set 4 Press the a button to quit Delete User Codes 1 Enter programming mode 2 Enter one of the code groups from 01 to 40 3 Press the button to delete the codes of which position you just inputted E g input 01 means delete the codes on the position 01 4 The code is successfully deleted when the unit beeps three Di Di sounds as a reminder 5 Press the X button to quit Delete a Code Directly Enter programming mode Press the button the unit will beep two Di Di sounds as a reminder Input the 4 digit code that you want to delete It is successfully deleted after the unit beeps three sounds Press the Ge button to quit Qr dum 18 APPLICATION DIAGRAM Camera Video Video Audio NC APS inside Inside Inside max 1 ur PEE dl 2 i NC MON4 NC MON4 SUB NC MON4 SUB AC 4C 4C 2C 2G ai 2C Power Power Power AC POWERDC AC POWERDC AC POWERDC AC POWERDC Power Supply for Lock A Power Supply for Lock A E Se Door Lock Door Lock A Door lock requires a seperate power supply NOTE Power supply AC POWERDC sold separately PARTS amp FUNCTIONS COLOR IR CAMERA OUTDOOR STATION we Name Description Protect the camera from outside water 2 LED Assistant Provide lighting during night time for better visibility CCD Camera
12. nd Li ch D 73 r 3 Yellow Power HH F3 12V DC o 4 White Video Outdoor Doar Look Outdoor Doar Look Station 2 Station 1 4 Requires a separate power supply Note Socket CN 1 is just retained for outdoor station in alone system like as an outdoor unit is matched with an indoor unit Please recheck the polarity of CN1 and have the 4 wire connected as per the enclosed label 12 INSTALLATION NC DS2 Recessed mounting Back cover NC DS2 ST NC DS2 SLIM
13. ny component is missing damaged IMPORTANT NOTE The Main monitor NC MON4 and Sub monitor NC MON4 SUB must be used with Sentry US s 14 5V DC power supply AC POWERDC and each monitor requires its own power supply CODE ACCESS FOR NC DS2 KP The original factory defaulted Programming Master Code is 1234 Input a 4 digit password to have the door strike or the lock unlocked Change the Master Code 1 Shutdown the power of the unit by pressing down and holding the X button 2 Press the X button again to turn on the unit a long continuous tone will sound 3 When the tone stops another tone will beep Enter the new 4 digit Master Code Entering Programming Mode 1 Press the X button plus enter your 4 digit Master Code 2 You have successfully entered the programming mode when the unit beeps three sounds and the LED is flashing 3 Press the E button to quit Set the Unlocking Time Factory default setting is 5 seconds 1 Enter programming mode 2 Enter 00 this is a special code group the unit will beep two Di Di sounds as a reminder 3 Enter a 2 digit desired lock delay operation time 01 to 99 seconds 4 Press the a button to exit Add User Codes 1 Enter programming mode There are 40 group codes to choose from 01 to 40 It should be inputted in front of the 4 digit codes from 31 to 40 group codes Input once 4 digit codes to open the door for a long time until twice the same code to have it clos
14. ound on o Two 2 Wall Anchors 4 Continuously press the button seven times to delete all settings Unlocking n t o One 1 Power Connector Cable time turns to one second The Admin Codes are same as before After 5 o Two 2 4 wire Connector Cables seconds all settings will set back to default e Oe Mama 5 Press the X button to quit NC DS2 KP works with code only No EM Card NC MON4 SUB e One 1 NC MON4 SUB SPECIFICATIONS One 1 Metal Mounting Bracket Two 2 Short Mounting Screws COLOR IR CAMERA OUTDOOR STATION 2 Two 2 Wall Anchors Model NC DS2 NC DS2 ST NC DS2 SLIM NC DS2 KP One 1 Power Connector Cable Standard Standard Sim With K d Two 2 4 wire Connector Cables Ha ud d One 1 Manual Power 12V 14 5V DC Electric Image 1 3 CCD 420 TV Lines Camera Lens 72 ken 3 6mm Lens OQ OQ 0 O O Q Illumination 0 05 Lux Communicatio NC APS Communicatio e One 1 NC APS n Method Duplex communication type o One 1 Mounting Plate Working m Two 2 Wall Anchors One 1 4 wire Connector Cables AN AN e e L E O O O OQ df One a L 9 06x5 91x1 69 in 3 54x5 12x1 69 in 2 17x5 12x1 54 in 2 95x7 48x1 77 in 230x150x43 mm 90x130x43 mm 55x130x39 mm 75x190x45 mm Specifications are subject to change without notice For any returns please include all components listed above with original packaging in Resalable Condition Absolutely No Returns will be accepted if a
15. tor screen 17 2 Monitor NC DS2 KP Pass Code ls m d This function is to see the image of RED o ress the MONITOR entrance Additional Audio Phone Set 1 button Jmm A Light Sensor e E B LED Indicator C Keypad Access WHITE o L 2 z x Lu Push to make o FOR EXIT Press once Press twice Uia l switch for exit F 7 7 k OOOO v 36 40 UT Outdoor station Outdoor station2 i Normal Open view view Normal Closed E um The LEDG is The LED is Se le lighting in blue lighting in blue La bel color color 4 5S felt li Uu UM KI D i Ss i T ai T 12V DC power supply Press the cancelling U PO button only when N M the slave monitor ege is in monitor RED lp k situation J v BLUE E3 From Monitor CN1 EX Power Supply YELLOW for Video amp Audio Plug in to Monitor End the monitor WHITE Al Do not use D Power Supply to Power the Keypad EGR D Must provide power to the Keypad separately ov 6 L1 B Power Supply For Keypad amp Lock if the lock requires 12V DC Dr Fail Safe gt NC H Strike Lock e Fail Safe to e Fail Security to 4 Requires a separate power supply 16 9 PARTS amp FUNCTIONS COLOR MONITOR INSIDE STATION NC MON4 amp NC MON4 SUB LOTS Inno SER et HHHHHHHHHHHHI T EE a n Microphone SE ole wem 5 reem
16. x 5 12 x 1 69 90mm x 130mm x 43mm NC DS2 KP code only 1 3 CCD 420 TVL 0 05 Lux 3 6mm Lens Hands free Talking 120 sec Communication Duration Duplex Communication Type Personal Password Door Release Surface Mounting IP55 Rating 12V 14 5V DC 100mA 2 95 x 7 48 x 1 77 75mm x 190mm x 45mm NC MON4 SUB 7 Screen 2 min Talking Time Dual Transmission Mode Surface Mounting 12V 14 5V DC 700mA 50 60Hz Stand by 70mA 9 45 x 6 89 x 1 5 240mm x 175mm x 38mm Access Control Readers Proximity ID Reader Mifare IC Reader ACR EM26SA ACR MF26SA 125 kHz 9V 15V DC 13 56 MHz 9V 15V DC E Wiegand 26 IP 65 Wiegand 26 IP 65 2 Current 35mA avg 100mA peak Current 35mA avg 100mA peak x 46mm 2 99 j Proximity ID Reader Mifare IC Reader ACR EM26STA ACR MF26STA 125 kHz 9V 15V DC 13 56 MHz 9V 15V DC io E Wiegand 26 IP 65 Wiegand 26 IP 65 v Current 35mA avg 100mA peak Current 35mA avg 100mA peak i 6mm 4 99 Proximity ID Reader Mifare IC Reader 6 ACR EM26STB ACR MF26STB 125 kHz 9V 15V DC 13 56 MHz 9V 15V DC n E Wiegand 26 IP 65 Wiegand 26 IP 65 y Current 35mA avg 100mA peak Current 35mA avg 1 81 Proximity ID Reader Mifare IC Reader GEES ACR EM26STC ACR MF26STC 125 kHz 9V 15V DC 13 56 MHz 9V 15V DC Wiegand 26 IP 65 Wiegand 26 IP 65 E Current 35mA avg 100mA peak Current 35mA avg 5 100mA peak ra t A me 22 INDEX FPERTORE