Home

Controls/Handsets

image

Contents

1. Desk User III Position Position I is flashing digits counting from 117 to 88 When the desk has reached the new height position I it will stop flashing If the buttons are not activated for 15 sec the clock function will appear in the display Page 33 of 44 Disposal of LINAK s products As LINAK s customers often ask us how our products can be disposed of or scrapped we have prepared this guidance that enables a classification to different waste fractions for recycling or combustion Guidance We recommend that our products be disassembled as much as possible and divided into different waste groups for recycling or combustion For example waste can be sorted into metals plastics cable scrap combustible material and recoverable resources Some of these main groups can be further divided into subgroups e g metal can be divided into steel aluminium copper and plastic can be divided into ABS PA PE PP As an example the table below breaks down the different components in LINAK products to various recycling groups Product Components Recycling group Handset Control Plastic housing Plastic recycling or combustion Cable Cable scrap or combustion PCB board Electronics scrap By now almost all our casted plastic parts are supplied with an interior code for plastic type and fibre contents if any Main groups of disposal Product main Metal Cable Electronics Plastic recycling or Co
2. WE IMPROVE YOUR LIFE MA M9 02 350 G LINAK A S reserve the right to make technical alterations Copyright O LINAK 2015 10
3. 0288 Fax 65 6844 0070 E mail servodynamics servo com sg www servo com sg SOUTH AFRICA Industrial Specialised Applications CC Phone 27 11 312 2292 or 27 11 2077600 Switch Board Fax 27 11315 6999 E mail gartht isagroup co za www isaza co za UNITED ARAB EMIRATES Mechatronics Phone 971 4 267 4311 Fax 971 4 267 4312 E mail mechtron emirates net ae www mechatronics ae Page 44 of 44 USA LINAK U S Inc North and South American Headquarters Phone 1 502 253 5595 Fax 1 502 253 5596 E mail info linak us com www linak us com NORWAY LINAK Norge AS LINAK AG Phone 47 32 82 90 90 Phone 41 43 388 31 88 Fax 47 32 82 90 98 Fax 41 43 388 31 87 E mail info linak no E mail info linak ch www linak no www linak ch SWITZERLAND POLAND TAIWAN LINAK Polska LINAK A S Taiwan Representative Office Phone 48 22 500 28 74 Phone 886 2 27290068 Fax 48 22 500 28 75 Fax 886 2 27290096 E mail dkreh linak dk Mobile 886 989292100 www linak pl E mail michael chenQlinak com tw www linak com tw TURKEY LINAK ith ihr San ve Tic A S REPUBLIC OF KOREA LINAK Korea Ltd Phone 82 0 2 6231 1515 Fax 82 0 2 6231 1516 Phone 90 312 4726338 E mail scullyQlinak kr Fax 90 312 4726635 www linak kr E mail info linak com tr RUSSIAN FEDERATION Mk 000 LINAK UNITED KINGDOM Phone 7 495 280 14 26 LINAK UK Limited Fax 7 495 687 14 26 Phone 44 0 121 544 2211 E mail infoBlinak
4. A S Smedev nget 8 DK 6430 Nordborg Name and address of the person authorized to compile the relevant technical documentation John Kling Group Headquarters Guderup DK 6430 Nordborg email jklQlinak com Herewith declares that LINAK Actuators and Actuator Systems comply with the following parts of the Machinery Directive 2006 42 EC ANNEX I Essential health and safety requirements relating to the design and construction of machinery 1 5 1 Electricity supply Directive 2006 95 EC on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 1 5 10 Radiation 1 5 11 External radiation Directive 2004 108 EC on the approximation of the laws of the Member States relating to electromagnetic compatibility The relevant technical documentation is compiled in accordance with part B of Annex VII and that this documentation or part hereof will be transmitted by post or electronically to a reasoned request by the national authorities This partly completed machinery must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of this Directive where appropriate Date 2010 01 01 Signature John Kling Certification and Regulatory Affairs Page 7 of 44 Misc on the DESKLINE system Warranty 60 months on DESKLINE NEW This will be valid for all DESKLINE products produced after the 1
5. Liaison Office Phone 91 120 4393335 Fax 91 120 4273708 E mail info linak in www linak in IRELAND LINAK UK Limited Ireland Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 44 0 796 855 1606 UK Mobile SLOVAKIA LINAK Slovakia s r o Phone 421 51 75 63414 Fax 421 51 75 63 410 E mail jp linak sk www linak com ITALY LINAK Italia S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it JAPAN LINAK K K Phone 81 45 533 0802 Fax 81 45 533 0803 E mail linak linak jp www linak jp MALAYSIA LINAK Actuators Sdn Bhd Phone 60 4 210 6500 Fax 60 4 226 8901 E mail info linak asia com www linak my NETHERLANDS LINAK Actuator Systems B V Phone 31 76 5 42 44 40 Fax 3176542 6110 E mail info linak nl www linak n NEW ZEALAND LINAK New Zealand Ltd Phone 64 9580 2071 Fax 64 9580 2072 E mail nzsalesQlinak com au www linak co nz 35 387 634 6554 Republic Of Ireland Mobile E mail sales linak co uk www linak co uk INDONESIA Pt Himalaya Everest Jaya Phone 6 221 544 8956 8965 Fax 6 221 619 4658 1925 E mail hejplastic div centrin net id www hej co id IRAN Bod Inc Phone 98 2188998635 6 Fax 98 2188954481 E mail info bod ir www bod ir RUSSIAN FEDERATION 000 FAM Phone 7 812 3319333 Fax 7 812 3271454 E mail purchase fam drive ru www fam drive ru SINGAPORE Servo Dynamics Pte Ltd Phone 65 6844
6. Recognized Component mark for Canada and United States Intertek RECOGNIZED OMPONENT EI Conforms to ANSI AAMI Std ES60601 1 Poa EE Cert to CSA Std 22 2 No 60601 1 ETL Recognized Component mark for Canada and United States Intertek RECOGNIZED COMPONENT Ti C N 4008623 EI Conforms to ANSI AAMI Std ES60601 1 Cert to CSA Std C22 2 No 60601 1 ETL Recognized Component mark for Canada and United States Intertek Page 8 of 44 RECOGNIZED GQ a ETL Recognized Component mark for Canada and United States Intertek RECOGNIZED COMPONENT Ti C N 4008838 EI Conforms to ANSI AAMI Std ES60601 1 o Cert to CSA Std C22 2 No 60601 1 il ETL Recognized Component mark for Canada and United States RECOGNIZED COMPONENT pp A e mtertek ETL Recognized Component mark for Canada and United States RECOGNIZED COMPONENT Tl C N 9901916 y Conforms to ANSI AAMI Std ES60601 1 CNG EJ US Cert to CSA Std C22 2 No 60601 1 Intertek ETL Recognized Component mark for Canada and United States 18 Page 9 of 44 Overview of the DESKLINE Controls product range The desk panel is used to operate the DESKLINE system The desk panel product range consists of number of desk panels with different functions For single parallel drive without memory DPA DPB DP1K DP1V DPF1K DPH and DPF1D DPA Desk Panel DPB Desk Panel DP1K Desk Panel DPH Desk Panel For single parallel drive with mem
7. SM Label for DPF3K LINKE AP WE IMPROVE YOUR LIFE Item DPF3K00 010006 P O 123456 0001 ASSEMBLED IN CHINA m DRAWING APPENDIX DESKLINE DPA DPB with drawer Sy OFS TR V DP1C Desk Panel vik DP1CS Desk Panel DPF1K Desk Panel Page 37 of 44 DPF2K Desk Panel E oEOEESC DPF3K Desk Panel DPF1M Desk Panel DPF1C Desk Panel with display 93 5 Page 39 of 44 DPFAT Desk Panel 50000 DPH Desk Panel ECTION A A DPT Desk Panel WDP WDP fitting for desk Page 41 of 44 DECLARATION OF CONFORMITY LINAK A S Smedeveenget 8 DK 6430 Nordborg hereby declares that LINAK Actuator System composed of Control Box s CBD4 CBD5 CBD6 And Linear Actuator s 31xxxH xxxxx50S DB4 DB5 DB6 DB7 DB9 DB14 DB16 and or Lifting Column s DL1A DL2 DL4 DL5 DL6 DL7 DL8 DL9 DL10 D
8. box The WDPL will also work on a CBD4 CBD5 with mains cut off The clock will only be shown if you have battery backup The cable from the WDPL is connected to the control box under your table Control box Wired WDPL WDP fitting for desk Figure 11 Display layout WDPL Flashing when activated Error Squeeze Store inch sign sa ao zj mode PMi C T C 4 digits for height Desk III User III Position III and clock mode Active in clock and height mode Page 29 of 44 Calibrating the WDPL For the WDPL to function correctly you have to calibrate your system This has to be done before using the WDPL You only have to do this once Action Display view 1 Switch between cm and inch Press and hold and then press 6 G A CO Desk I User 2 Measure the height from desk to floor If only one desk is connected go to point 4 3 Press esi and then press Q or to select desk If only one desk is connected it is not possible to select Desk II or III 4 Press and hold and then press Ne W to adjust the height in the display Example The display will switch from e g 68 to 69 70 71 etc when is pressed and held and then is pressed and e g 68 to 67 66 etc when is pressed and held and then W is pressed 5 When the wanted height is shown in the display press and hold and then pes The reference height of the desk will now be stored in the control bo
9. close to the tabletop Example 3 Article number 914760 The panel is mounted with a 45 bracket and placed at the edge of the tabletop To mount the panel Just click the panel into the bracket and it is fixed Example 2 Article number 914757 The panel is mounted with a 90 bracket and place with a distance to the tabletop Example 4 Article number 914785 The panel is mounted with a 45 bracket and placed on a tabletop with angled front Drawings of the mounting brackets Article number 914759 Article number 914757 T Article number 914760 Article number 914785 ee o o v V 34 34 Page 25 of 44 Operation of the DPT For safety reasons the DPT has a locking function ud If the DPT is locked only a bar is lightning in the display To unlock the control press S for 1 sec When SO the DPT is unlocked the height will be shown in the display Now the DPT is active for 2 5 seconds When pressing one of the keys you can do your adjustment Hereafter the DPT will be active for 5 seconds but when there are no activations made within the mentioned time slot the DPT will go in to locking mode again Also if you press S for unlocking too long the DPT will unlock but immediately lock again The Touch Desk Panel is used to operate the DESKLINE systems The DPT is divided into parallel and memory drive The two arrow buttons are used for parallel drive and the last four butt
10. height can be adjusted the display will show three minuses hereafter the display will revert to showing the height The height can then be adjusted by either A or V until the desired height has been reached The system will return to normal operation and give a short blink after 5 seconds of inactivity on the keys The feature can be disabled via configuration in which case pressing the A and V keys at the same time will be considered an illegal keypress Switch between cm and inch Switching between cm and inch can only be done via the DPF configurator Adjusting the light intensity of the LED display Possible settings are Off 6 12 19 25 37 50 75 and 100 The adjustment can only be done via the DPF configurator Adjusting the light timeout Possible settings are 0 15 seconds and Off The adjustment can only be done via the DPF configurator Error codes Below please find the possible error codes that can be displayed The error codes will only be displayed when a button is pressed The display will blink while showing the error code The E16 error will overrule any other errors as the detection is registered only in the display and no message is send to the control box Error no Description E01 The desk has an unknown position and needs to be initialised E02 Overload in upward direction has occurred E03 Overload in downward direction has occurred E16 Illegal keys are pressed Page
11. ru Fax 44 0 121 544 2552 www Ilinak ru E mail sales linak co uk SPAIN www linak co uk LINAK Actuadores S L u Phone 34 93 588 27 77 Fax 34 93 588 27 85 E mail linakact linak es www linak es SWEDEN LINAK Scandinavia AB Phone 46 8 732 20 00 Fax 46 8 732 20 50 E mail info linak se www linak se For contact details on other countries please visit www linak com or contact LINAK INTERNATIONAL Phone 45 73 15 15 15 Fax 45 74 45 90 10 Fax 45 73 15 16 13 Sales E mail info linak com www linak com Terms of use The user is responsible for determining the suitability of LINAK products for specific application LINAK takes great care in providing accurate and up to date information on its products However due to continuous development in order to improve its products LINAK products are subject to frequent modifications and changes without prior notice Therefore LINAK cannot guarantee the correct and actual status of said information on its products While LINAK uses its best efforts to fulfil orders LINAK cannot for the same reasons as mentioned above guarantee the availability of any particular product Therefore LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK All sales are subject to the Standard Terms of Sale and Delivery for LINAK For a copy hereof please contact LINAK LINAK E
12. the display shows the actual height of the desk Switch between cm and inch Switching between cm and inch can only be done via the DPF1C configurator Page 26 of 44 Error Codes The DPT has capability of displaying error codes for diagnostic feedback Below are possible feedback errors which can be displayed by the DPT The error codes will only be displayed when a button is touched in unlocked mode The display will blink while showing the error E16 overrules any other error since the detection is registered only in the display and no message is sent to the control box For detailed error description and codes please see the appropriate CBD software description Error no Description E01 The desk has an unknown position and needs to be initialised E02 Overload in upwards direction has occurred E03 Overload in downwards direction has occurred E16 Illegal keys are pressed Page 27 of 44 Mounting of the DPT The hole in the tabletop has to be made according to the drawing The DPT is mounted in the hole and the two screws on the backside are fastened with a maximum torque of 40 Ncm If you do not have a torque screw driver please tighten gently and not more until you can feel a slight resistance Do not use electrical tool Please note i A 3 Mounting the DPT into the tabletop should be done at the end user so the product will not be exposed to any stress which can destroy the product w
13. these instructions can result in the product being quo damaged or being destroyed Safety instruction N General Safe use of the system Is possible only when the operating instructions are read completely and the instructions contained are strictly observed Failure to comply with instructions marked with the NOTE symbol may result in serious damage to the system or one of its components It is important for everyone who Is to connect install or use the A systems to have the necessary information and access to this User Manual Follow the instructions for mounting risk of injury if these instructions are not followed AN The appliance Is not intended for use by young children or infirm persons without supervision N If there is visible damage on the product it must not be installed N Note that during construction of applications in which the actuator is to be fitted there must be no possibility of personal injury for example the squeezing of fingers or arms net Assure free space for movement of application in both directions to 7 avoid blockade Page 5 of 44 Only for EU markets This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the app
14. 16 of 44 Remote control HB10RF HB20IR Operation of the system The HB21 IR transmitter is a simple up down control with gt a button for the up activation and a button for the down r activation of 1 reference on the CBD The HB22 is a two channel controller for controlling two references on the CBD For activation of the control box point with the HB20 at the DP1V or the extension eye Press the button up or down The operation range for the HB20 is approx 6 m Drawings DP1V Position of the internal eye Connector for extension eye IR extension eye article number 0964571 2000 530 16 12 The IR extension eye is for mounting in a 12 mm hole The eye has a 2000 mm cable with a mini Jack plug which is to be plugged into the DP1V Page 17 of 44 Activating the learning mode Activate the reset key on the RFR by using a pen or similar to keep the button pressed e Keeping the reset key activated the RF handset must be activated by pressing a random key on the RF handset The RF handset IDs are stored in the memory and at the same time previous RF handset IDs are erased e After having activated the RF handset keys the reset key must be released If no RF handset keys are activated during the matching procedure no changes are made in the ID memory e Please be aware that other equipments as e g doorbells which use the 433 MHz can disturb the RF signal Every RF handset has its own 32
15. 2 MADE BY LINAK A S DENMARK S Wor DAM W O 41234967 0001 NOT TO BE OPENED BY UNAUTHORIZED PERSONNEL Label for DP1CS LINAK 3 heana LO HEADQUARTERS WE IMPROVE YOUR LIFE SMEDEVAENGET 8 DESIGNED IN DENMARK DK 6430 NORDBORG Item DP1CS00 100006 IPXO Date 2015 10 23 S W 0077025 rev 1 10 gt ASSEMBLED IN CHINA NOT TO BE OPENED BY UNAUTHORIZED PERSONNEL amp MOA ADA p 0 123456 0001 A C amp Label for DPF1D LINAK d HEAD OUARTERS lt i gt WE IMPROVE YOUR LIFE SMEDEVAENGET 8 DESIGNED IN DENMARK DK 6430 NORDBORG C Item DPF1D00 012006 S W 0077025 rev 1 10 ON P O 123456 0001 ASSEMBLED IN CHINA A Label for DPF1K LINAK E CAD WE IMPROVE YOUR LIFE Item DPF1K00 010006 P O 123456 0001 ASSEMBLED IN CHINA ra Label for DPH DPH1K10 200006 P O 191107 Label for DPT 0077022 Ver 1 02 P 0 123456 0001 Label for WDPL LINAK G WE IMPROYE YOUR LIFE Item WDPL 1000 000001 IP40 Date 2006 05 09 P O 123456 0000 S W P N 0077006 Ver B1 11 MADE BY LINAK AS DENMARK NOT TO BEOPENED BY UNAUTHORI ZED PERSONNEL Label for DPF2K Label for DPF EN cego hen LINAK E c A 0 WE IMPROVE YOUR LIFE Item DPF2K00 010006 P O 123456 0001 ASSEMBLED IN CHINA Page 35 of 44 The label is printed directly on the DPB KR NN DPBK06 PO 299218 Label for DPF1C EN cea
16. 5 of May 2015 Products produced before 1 of May 2015 will still be covered by 36 months Products used in DESKLINE application If these products are used in another application they will be covered by 18 months warranty If there is any doubt that returned products are within the warranty period it is to be treated as if they are covered by the warranty We recommend that you use the date of the Control box or actuator as reference if possible We will have our purchase no printed on the label Maintenance Clean dust and dirt on the outside of the system at appropriate intervals and inspect for damage and breaks Inspect the connections cables and plugs and check for correct functioning as well as fixing points vg The cleaners and disinfectants must not be highly alkaline or acidic pH value 6 8 ETL marking Due to space limitations the complete ETL marking demands are not represented on the marking plates The full ETL Recognized Component markings are shown here RECOGNIZED COMPONENT am 2 Cert to CSA Std C22 2 No 60601 1 ETL Recognized Component mark for Canada and United States Intertek RECOGNIZED COMPONENT 4 C N 4008003 EI Conforms to ANSI AAMI Std ES60601 1 sore Cert to CSA Std C22 2 No 60601 1 ETL Recognized Component mark for Canada and United States Intertek RECOGNIZED COMPONENT Ti C N 4008004 EI Conforms to ANSI AAMI Std ES60601 1 ware Cert to CSA Std C22 2 No 60601 1 ETL
17. DESKLINE IMPROVING ERGONOMICS Controls Handsets LINAK E WE IMPROVE YOUR LIFE To learn more about LINAK please visit Page 1 of 44 Page 2 of 44 Contents PP LL 4 Safety INSTrUCTIONS es ces oiro Rise DOSES DID OO EEE TO EAE AEAEE E DEAR 5 FNS NN 7 Manufacturer s declaration annan vnr vnr vnr anna enna 7 Misc on the DESKLINE system soausiiannesssaeia nas esa AT SSD ERRER EEEE EErEE EE 8 WAIN ee E E E E RR RR 8 WAERED E E ERE EE RE TE ERE EE 8 SE 4 EEE EEE EN EE 8 Overview of the DESKLINE Controls product range mmnrnrrsavrrrnnrrrrrrnrnnrrrrrrvnrnnrrrrrnnnnrrnrrnnnnrrrrrrnnnnrnrrrnnnn 10 Mounting guidelines for DPA DPB rrrrnrrnnrrrrrrnrnrnnnnnnnnnrrrrrrrrrnnnnnnnnrrnerrsrrsnnnnnnnnnrenerrrrrrnnnnnnnnrnrrrrrrrnnnnnnnnn 11 Mounting guidelines for DPH mrrrrsarsrrnrrrrrnrrrrrrrarrrrnrrnnnnrrrrrsrrnnnnnnnnnnrenerrsrrnn an nnnnnnrrnersrrdnn an nnnnnnrnnerrrrrnnnnnnnnn 11 PTE 11 Operation of the simple desk panels cc aeee 12 Operation OF the DPIC Lv442asaremsssnmesearenTTGNALGGETGL akten a 13 PTE Sv 15 Remote control HBTORF HBZOIR si sssianisnana sos iss gaga EEan EErEE 17 Activating the learning TONS ERE EEE SR ui dd 18 Operation of the DPF aeee aaa aerea era eae errar 19 MN 19 AGE aro EG 51 REE EE coer 19 FN A peut E 19 Operation of the DPF1C one reference oo cc LLL errar 20 Operation of the PFIN esparsa 21 Operation of the DPF4T mu
18. L11 DL14 DL15 DL16 And Desk Panel s DP1C DP1K DPT DPB DPF DPBK DP1L DP1V DPA DPH WDPL1 and or Handset s HB2xxF2 00003 complies with the EMC Directive 2004 108 EC according to following standards EN 61000 6 1 2001 EN 61000 6 3 2001 EN 55022 1998 A2 Class B and complies with Low Voltage Directive 2006 95 EC according to the standard EN 60335 1 2002 A1 2004 A11 2004 A12 2006 A2 2006 A13 2008 and complies with Machinery Directive 2006 42 EC according to the standard EN 13849 1 2008 SRP CS Cat B PL b and SRESW PL b And Controls RF transmitter HB1XRFXXXX and or RF transmitter HB2XRFXXXX and or RF receiver RFRL complies with the Radio equipment and Telecommunications terminal equipment Directive 1999 5 EC EN 300220 2 2006 EN 61000 6 1 2007 EN 61000 6 3 2007 EN 60335 1 2002 A1 2004 A11 2004 A12 2006 A2 2006 A13 2008 EN 62311 2008 Nordborg 2011 05 25 e doa LINAK A S John Kling B Sc E E Certification and Regulatory Affairs Authorized to compile the relevant technical documentation Page 42 of 44 LINAK APPLICATION POLICY The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware software technical advice etc related to an existing or new customer application LINAK products as defined above are applicable for a wide range of applications within the Medical Furniture Desk and Industry areas Yet LINAK
19. The feature can be disabled via configuration in which case pressing the A and V keys at the same time will be considered an illegal keypress Switch between cm and inch Switching between cm and inch can only be done via the DPF1C configurator Adjusting the light intensity of the LED display Possible settings are Off 6 12 19 25 37 50 75 and 100 The adjustment can only be done via the DPF1C configurator Adjusting the light timeout Possible settings are 0 15 seconds and Off The adjustment can only be done via the DPF1C configurator Page 23 of 44 Error codes Below please find the possible error codes which can be displayed The error codes will only be displayed when a button is pressed The display will blink while showing the error code The E16 error will overrule any other errors as the detection is registered only in the display and no message is send to the control box Error code Description EQT The desk has a unknown position and needs to be initialised E02 Overload in upwards direction has occurred E03 Overload in downwards direction has occurred E16 Illegal keys are pressed Mounting of all DPF versions The DPF must be mounted via a mounting bracket The mounting bracket comes in 4 different versions de pending on how the panel should be mounted Below are some examples on ways to mount Example 1 Article number 914759 The panel is mounted with a 90 bracket and placed
20. The function is only activated when holding down the button Store memory 5 e Pushi S e Within two sec push either EN 2 or 3 Choice of user U only DP1N Two persons can store 2 memory positions each Select user 1 or user 2 e Push U e Within two sec push either or 2 Store memory S e Pushi S e Within two sec push either 1 or 2 Memory drive 1 2 3 Memory 1 2 and 3 start a memory drive the channel s DPH Desk Panel drive to a preprogrammed position GI Page 12 of 44 Operation of the DP1C The DP1C cannot be used on the CBD4 with mains cut off Description The DP1C is equipped with display and memory and is compatible with CBD4 Advanced software 077402 ver 1 66 or later The DP1 is only available as a 1 channel version for operation of the parallel channels up and down The actual height of the desk is shown in the display The display is of the LED type with a yellow light and 10 mm high digits PAN Desk up Desk down Store memory 1 U S Vv S 1 Memory 1 2 3 Memory 2 Memory 3 Normal operation To run the desk up or down press the UP or DOWN button and keep it pressed until the desk reaches the desired height The display will count up or down while running and after stop it
21. arallel drive and the last four buttons for memory drive storing memory A Parallel up V Parallel down S Store memory ad Memory 1 ee Memory 2 eee Memory 3 Parallel drive AV The arrow buttons start parallel drive The function is only activated when holding the button down Store memory e Press S button e Within two seconds press one of the small buttons with dots and the position will be stored at this button Memory drive small buttons with dots Press one of the memory buttons and the system will start driving to the pre programed memory position Keep the button pressed until the position is reached Page 19 of 44 Operation of the DPF1C one reference DPF1C Desk Panel A Parallel up V Parallel down S Store memory Memory 1 ee Memory 2 eee Memory 3 Up and down A V Just activate either the up or down button for parallel drive and the system will drive until the button is released again or the system reaches end position Memory The four small buttons are used for memory drive storing memory Store memory e Press S button the display will flash for 2 seconds e Within these two seconds press one of the small buttons with dots and the position will be stored at this button e The panel will acknowledge by showing 1 2 or 3 in the display depending on chosen position Memory drive small buttons with dots Press one of the
22. bit unique address and the RF protocol contains a check sum which ensures that only the handset that has been activated during the learning process can activate the system No noise signal from other RF equipment can activate the system but might prevent it from running depending on the signal strength of the noise signal The operation range for the HB10 is approx 6 m but depending on the surroundings where it is mounted it can be less E g if the receiver is mounted in a cabinet along with other equipment The RF uses the frequency 433 MHz Page 18 of 44 Operation of the DPF K version DPF1K Desk Panel Just activate either the up or down button for parallel drive and the system will drive until the button is released again or the system reaches end position 2K version Just activate either the up or down button and the system will drive until the button is released again or the system reaches end position Each set of up down buttons refers to a reference You can only drive one reference at a time The desk panel can have up to 2 references 3K version Just activate either the up or down button and the system will drive until the button is released again or the system reaches end position Each set of up down buttons refers to a reference You can only drive one reference at a time The desk panel can have up to 3 references M version The DPF is divided into parallel and memory drive The two arrow buttons are used for p
23. cannot know all the conditions under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humidity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK product LINAK shall be responsible solely that the LINAK products comply with the specifications set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specific LINAK product can be used for the application in question Page 43 of 44 FACTORIES CHINA LINAK Shenzhen Actuator Systems Ltd Phone 86 755 8610 6656 Fax 86 755 8610 6990 E mail sales linak cn www linak cn SUBSIDIARIES AUSTRALIA LINAK Australia Pty Ltd Phone 61 3 8796 9777 Fax 61 3 8796 9778 E mail sales linak com au www linak com au AUSTRIA LINAK Repr sentanz sterreich Wien Phone 43 1 890 7446 Fax 43 1 890 744615 E mail info linak de www Ilinak at BELGIUM amp LUXEMBOURG LINAK Actuator Systems NV SA Phone 32 0 9 230 01 09 Fax 32 0 9 230 88 80 E mail beinfo linak be www linak be BRAZIL LINAK Do Brasil Com rcio De Atuadores Ltda Phone 55 11 2832 7070 Fax 55 11 2832 7060 E mail infoQlinak com br www linak com br CANADA LINAK Canada I
24. eat every 100 msec Releasing all buttons stores the new setting Errors Below please find the possible errors that can be displayed The errors will only be displayed when a button is pressed The display blinks while showing the error E16 overrules any other error as the detection is registered only in the display and no message is sent to the control box Diagnostic errors The CBD4 version 1 86 or later can send up to 6 different diagnostic error codes at the same time The diagnostic error codes will overrule error states except E16 Diagnostic errors will only appear as long as the button is pressed The display will blink EXX and will toggle through the diagnostic errors and send them to the LINBUS in the CBD For detailed error description and codes please see the appropriate CBD software description Only working with DP1C from production date 1 february 2006 and onwards Error no Description E01 The desk has an unknown position and needs to be initialised E02 Overload upwards has occurred E03 Overload downwards has occurred E16 Illegal keys pressed Page 14 of 44 Operation of the DP1CS Description The DP1CS is equipped with display and memory and is compatible with DESKLINE control boxes The DP1CS is available as a 1 channel version for operation of the parallel channels up and down The actual height of the desk is shown in the display The display is of the LED type with a yellow ligh
25. eep the button pressed until the position is reached The display will show the actual height during the memory run Adjust the display to show the correct height It may be necessary to adjust the display due to different thicknesses of desktops etc when the DP is delivered from the factory The DP will show 68 cm or 24 5 inches default setting height of the desk At the same time press the Store button and step UP or DOWN until the display shows the correct height Adjusting the light intensity of the LED display Possible light settings are O off 25 25 50 50 75 75 100 100 Adjustment procedure Press the 1 button and at the same time either desk up or desk down this will adjust the light intensity Initial press will show the current setting Keep the 1 button pressed during the whole sequence while adjusting up or down Keep a button pressed for more than 800 msec then the button will auto repeat every 100 msec Releasing all buttons stores the new setting Page 13 of 44 Adjusting the light timeout Possible light timeouts are 0 15 sec and off Adjustment procedure Press the 3 button and at the same time either desk up or desk down this will adjust the light timeout Initial press will show the current setting Keep the 3 button pressed during the whole sequence while adjusting up or down Keep a button pressed for more than 800 msec then the button will auto rep
26. hen transported For countersink versions the technician must ensure that the acrylic plate is not put under pressure which will push the acrylic plate out of place The screws which are delivered with the product must be used If they have gone lost there should not be chosen new screws which are longer than 12 mm otherwise top and bottom will disconnect If the product has visible damages it should not be mounted The product is IP30 the customers can be sure that fluids dust will not enter the product The front itself is closed by the acrylic plate s adhesive foil Cable release is specified for max 5 kg Remember to remove the protection foil Frame Countersink SECTION A A n 5 45 SECTION A A Page 28 of 44 Operation of the WDPL The batteries Wired WDPL Install 3 x 1 5 V batteries type AA The batteries are used as a backup of the clock function if the CBD is disconnected from the mains Figure 9 When the batteries are mounted the display will show the clock function in hh mm The clock has to be adjusted See adjusting the clock on page 22 Low battery Change batteries at weak contrast in the display or when the display shows strange symbols misinformation This does not influence the function of the WDPL it is exclusively a sign that the batteries are to be replaced The WDPL will also work without batteries because it will be powered by the control
27. liance Cleaning and user maintenance shall not be made by children without supervision Only for Non EU markets Persons who do not have the necessary experience or knowledge of the product products must not use the product products Besides persons with reduced physical sensory or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who Is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product Misuse Do not overload the actuators this can cause danger of personal A injury and damage to the system Do not use the actuator system for lifting persons Do not sit or stand on a table while operating risk of personal injury Do not use the system in environments other than the intended indoor use Page 6 of 44 Repairs In order to avoid the risk of malfunction all DESKLINE repairs must only be carried out by authorised LINAK workshops or repairers as special tools must be used and special gaskets must be fitted Lifting units under warranty must also be returned to authorised LINAK workshops Warning If any of the DESKLINE products are opened there will be a risk of subsequent malfunction Warning The DESKLINE systems are not resistant to cutting oil DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY LINAK
28. ltiple references 22 Other functions common for DPFIG and DPRAI aiii ennicarir topos didi iiiaaao dois sakeencabiubed did skeib annen 23 Mounting OF all DPF versions nu 52d midlet nddtsis sne 24 Drawings erverver 25 Operation OF the DPI sssiiiiisiaassbiiiibninDo nesidiaa ani dd da EEEEEEEEEEEE EEr 26 Mounting of the DPT ii creseccoonsssssesnnessansmesiesees enbechannpmennaaase chop seaddnnclsensdonne Sasbaenmadgaaas eonensdacadexeseadgnnssanoneumednsegsienses 28 Operation of the WUD PU oo eia 29 Calibrating tne WDP aac DOR ene sence RR SR DRDS RR URU RR E 30 NENNE 31 TNT 31 Store a memory os aa EE ESTE EE EE RENNENE 32 Switch to a stored memory 10S TOI EEE RN ee 33 Disposal of LINAK s products ee 34 Disposal of ba css hac creates ais Ra dO 34 LADEIRA E 35 Drawing appendix error EnEn EEEE een aaa aaa na aaa aaa nana anna anna aan aa nana anna anna na EEEE EEn 36 rs RER EEE EEE 44 Page 3 of 44 Preface Dear User We are delighted that you have chosen a product from LINAK LINAK systems are high tech products based on many years of experience in the manufacture and development of actuators electric control boxes controls and chargers This User Manual does not address the end user It is intended as a source of information for the manufacturer of the equipment or system only and it will tell you how to install use and maintain your LINAK electronics It is the responsibility of the manufacturer of the end use p
29. memory buttons and the system will start driving to the pre programmed memory position Keep the button pressed until the position is reached Display function Shows the actual height in either cm or inch Page 20 of 44 Operation of the DPF1D Display and up down drive DPF1D Desk Panel Parallel up G 3 Parallel down 4 N Ve CYC Function Compared to a standard DPF1C the DPF1D has no memory positions The panel is a simple one that will show the height when adjusting and error codes when needed Up and down V You just either have to activate the up or down button for parallel drive and the system will drive until releas ing the button again or when the system reaches end position Display function Shows the actual height in either cm or inch and can display error codes Page 21 of 44 Operation of the DPF4T multiple references DPF4T Desk Panel A Parallel up V Parallel down WN Store memory Toggle button N amp ths ee Memory I ee Memory 2 Function Compared to a standard DPF1C the first memory button on the DPF4T is replaced by a toggle button i e that the panel has 2 memory buttons instead of 3 memory 1 and memory 2 Besides the toggle button the DPF4T works like the DPF1C Up and down AV You just either have to activate the up or down button for parallel drive and the system will drive until releasing the b
30. mments groups Scrap scrap scrap combustion DPXX X X X WDPL X X X Disposal of batteries Details regarding safe disposal of used and leaking batteries Batteries should be disposed in accordance with appropriate federal state and local regulations LINAK recommends that used or leaking batteries are disposed through local recycling system Please do not throw used or leaking batteries in normal household waste or in nature This will cause damage to the enviroment How to deal with leaking batteries Leaking batteries should be disposed as described above If leaking batteries are discovered in the product the batteries must be removed at once to minimise damage to the product If leaking batteries are left in the product it become defective It is recommended to use plastic gloves when handling leaking batteries The contents of a leaking batteries can cause chemical burns and respiratory irritation If exposed to the contents of a leaking battery please wash with soap and water If irritation persists please seek medical attention In case of eye contact please flush eyes thoroughly with water for 15 minutes and seek medical attention Page 34 of 44 Labels Label DPA Label for DPB The label is printed directly on the DPA Label for DP GROUP NAK b HEADQUARTERS SM WE IMPROVE YOUR LIFE SMEDEVAENGET 8 DESIGNED IN DENMARK DK 6430 NORDBORG Item DP1000 000001 IPXO K Date 2015 10 2
31. nc Phone 1 502 253 5595 Fax 1 416 255 7720 E mail info linak ca www linak us com CZECH REPUBLIC LINAK C amp S S R O Phone 420581741814 Fax 420581702452 E mail ponizil linak cz www linak cz DISTRIBUTORS ARGENTINA Novotec Argentina SRL Phone 54 11 4303 8900 8989 Fax 54 11 4032 0184 E mail info amp novotecargentina com www novotecargentina com AUSTRALIA Ballarat Industrial Supplies www ballind com au BL Shipways amp Co www bishipway com au Gas Strut Marine and Industrial www gasstrutmarine com au Prime Motion amp Control www primehyd com au West Vic Industrial Supplies www westvicindustrial com au COLOMBIA MEM Ltda Phone 57 1 334 7666 Fax 57 1 282 1684 E mail servicioaldiente amp memltda com co www memltda com co DENMARK LINAK A S Group Headquarters Guderup Phone 45 73 1515 15 Fax 45 74 45 80 48 Fax 45 73 15 16 13 Sales E mail info linak com www linak com DENMARK LINAK Danmark A S Phone 45 86 80 36 11 Fax 45 86 82 90 51 E mail linak linak silkeborg dk www linak dk FINLAND LINAK OY Phone 358 10 841 8700 Fax 358 10 841 8729 E mail linak linak fi www linak fi FRANCE LINAK France E U R L Phone 33 0 2 41 36 34 34 Fax 33 0 2 41 36 35 00 E mail linakDlinak fr www linak fr GERMANY LINAK GmbH Phone 49 6043 9655 0 Fax 49 6043 9655 60 E mail info linak de www linak de INDIA LINAK A S India
32. ons for memory drive Desk up Es Desk down S Store memory 1 Memory 1 2 Memory 2 3 Memory 3 Normal operation To run the desk up or down press the a or v button and keep it pressed until the desk reaches the desired height The display will count the height as the table is moving and will continually show the height of the desk after stopping Storing a memory position Touch the S button and the display will flash S for 3 sec While the S is displayed touch the memory button 1 2 or 3 The display will acknowledge by showing S1 S2 or S3 for 1 sec To abort a store sequence press the A or v button while the S is flashing or wait the 3 seconds until the display automatically returns to show the height of the desk Drive to a stored position Press memory button 1 2 or 3 and the system will start driving to the desired memory position Keep the button activated until the position is reached The display will count the height as it is driving to the memory position Customising the DPT digital display Adjust the display to show the correct height The DPT will show 68 cm or 24 5 inches as the height of the desk as the default setting It may be necessary to adjust the displayed height due to different thicknesses of desktops etc when the DPT is delivered from the factory To adjust the display touch the S button and the aor v button at the same time until
33. ory DP1N DP1U DP1CS DPF1C DPF1M and DPT DP1N Desk Panel DP1U Desk Panel DP1CS Desk Panel For drive of more references DPFAT DPF2K and DPF3K DPFAT Desk Panel DPF2K Desk Panel DPF3K Desk Panel Page 10 of 44 Mounting guidelines for DPA DPB The DPA DPB can be mounted on the desktop so that the keys are either facing upwards or outwards Alternatively the DPA can be mounted flat under the desktop with the keys facing downwards Operation of the DPA DPB in connection with DESKLINE systems not CBD2N The Desk Panel is used to operate the DESKLINE system The two arrow buttons are used for parallel drive Parallel drive AV The arrow buttons start parallel drive The function is only activated when holding the button down vg The mounting screws on the DP DPA or DPB must be fastened with a max torque of 1 Nm Mounting guidelines for DPH SECTION A A a o A TAS Min dd vg The hole in the tabletop must be in accordance with this drawing Page 11 of 44 Operation of the simple desk panels Here you find the guide on how to operate the DPA DPB DP1K DP1N DP1U DP1V DPH and DP1CS Desk up DPA Desk Panel Desk down Store memory User memory Memory 1 Memory 2 wlis ella lt gt Memory 3 Single parallel drive 4 J The arrow buttons start the DESKLINE lifting column
34. roduct to provide a User Manual where relevant safety information from this manual is passed on to the end user We are sure that your LINAK product system will give you many years of problem free operation Before our products leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local dealer LINAK subsidiaries and some distributors situated all over the world have authorised service centres which are always ready to help you LINAK provides a warranty on all its products This warranty however is subject to correct use in accordance with the specifications maintenance being done correctly and any repairs being carried out at a service centre which is authorised to repair LINAK products Changes in installation and use of LINAK products systems can affect their operation and durability The products are not to be opened by unauthorised personnel The User Manual has been written based on our present technical knowledge We are constantly working on updating the information and we therefore reserve the right to carry out technical modifications LINAK A S Page 4 of 44 Important information Important information on LINAK products can be found under the following headings AN Warning Failure to comply with these instructions may result in accidents involving serious personal injury ud Failing to follow
35. t and 10 mm high digits Parallel up gt Parallel down nd NO D0000 ese 2 Memory 2 3 Memory 3 S Store memory Up and down AV You just either have to activate the up or down button for parallel drive and the system will drive until releasing the button again or when the system reaches end position Memory The four small buttons are used for memory drive storing memory Store memory e Press S button the display will flash S for 2 seconds e Within these two seconds press one of the small buttons with numbers 1 2 or 3 and the position will be stored at this button e The panel will acknowledge by showing 1 2 or 3 in the display depending on the chosen position Memory drive Press one of the memory buttons and the system will start driving to the pre programmed memory position Keep the button pressed until the position is reached Display function Shows the actual height in either cm or inch and can display error codes Page 15 of 44 Other functions Adjusting initial height lt may be necessary to adjust the displayed height due to different thicknesses of desktops etc The DP1CS will as standard show either 68cm or 24 5 inch as the default desk height Procedure Press A and V keys at the same time and keep them pressed for 5 seconds This allows the initial height to be adjusted Until the initial
36. tes All actuator ports must be used If you create a 2 reference system 2 parallel singles and only use three ports on a 4 channel control box the desk panel will show 723 You will be able to select reference three even through it is not connected The multi controller must not be used in combination with CBD4 software with the impulse drive feature There is a risk that the used software initiate impulse movement toggle to the next reference and therefore cannot stop the movement until it is back at the reference with impulse Memory positions 1A The memory position will be for all references When using memory one or two reference one will first drive to its memory position followed by reference two and so on Other functions common for DPF1C and DPF4T Adjusting initial height It may be necessary to adjust the displayed height due to different thicknesses of desktops etc The DPF1C will as standard either show 68 cm or 24 5 inch as the default desk height Procedure Press and V keys at the same time and keep them pressed for 5 seconds This allows the initial height to be adjusted Until the initial height can be adjusted the display will show three minuses hereafter the display will revert to showing the height The height can then be adjusted by either A or V until til desired height has been reached The system will return to normal operation and give a short blink after 5 seconds of inactivity on the keys
37. tton button combination Page 31 of 44 Store a memory position 3 users can store 3 memory posistions each The connected desks max 3 are to be adjusted individually one at a time Quick setup On the back of the WDP you will find a quick guide for storing a memory position Example Action Display view Desk User rm Flashing Ie Desk User If only one desk is connected go to point 4 1 Press 2 Press Q or until the wanted desk is shown in the display 3 Press 4 Press or 1 until the wanted user is shown in the display 5 Press No W until the wanted height is obtained 1 Desk User 6 Press and then Q or 1 Flashing Desk User Po The position is now stored in the control box To store a new memory position on the same desk go through points 3 to 6 again If the buttons are not activated for 15 sec the clock function will appear in the display Page 32 of 44 Switch to a stored memory position Quick setup On the back of the WDP you will find a quick guide for storing a memory position Example Action Display view 1 Press 2 Press Q or 1 until the wanted user is shown in the display 3 Press and hold OQ or ow all desks have reached their memory position The display will show the height of the moving desk for about 15 sec ti Desk User III Flashing 60
38. utton again or when the system reaches end position Memory The four small buttons are used for toggle function memory drive and storing memory Store memory e Press S button the display will flash for 2 seconds e Within these two seconds press one of the small buttons with dots and the position will be stored at this button 1A e The panel will acknowledge by showing 1 or 2 in the display depending on the chosen position Memory drive small buttons with dots Press one of the memory buttons and the system will start driving to the pre programmed memory position Keep the button pressed until the position is reached Display function Shows the actual height in either cm or inch Page 22 of 44 Toggle function Operation Press the Toggle button to toggle through all reference choices and make a selection to which reference you would like to use For example the display may show 123 press one more time and 234 is shown Since 3 is the bolded number you have now selected reference 3 and the up down buttons are running reference 3 up down When activating the up down button it first displays the reference number shortly for 4 sec then the actual height Reference setup is set in the CBD4 using the configuration software The DPF will automatically find out how the system Is configured One two three or four references If only two references exist 121 212 is shown in the display Important no
39. will continually show the current height of the desk Changing between cm and inches Keep the S button pressed for approx 4 sec and the reading will change from the current setting The default setting depends on the type chosen Store a memory position When pressing the store button the display will flash S for 3 sec Within the 3 sec press memory button 1 2 or 3 The display will acknowledge by showing S1 S2 or S3 for 1 sec To abort a store sequence press the UP or DOWN button while the S is flashing or wait the 3 sec until the display automatically returns to show the height of the desk Drive to a stored position Version with GO memory Press memory button 1 2 or 3 The display will flash GO1 GO2 or G03 for 3 sec Within the 3 sec press the UP or DOWN button and keep it pressed until the desk stops in the stored position Both the Up and the Down button will activate memory drive Although e g the memory position is higher than the actual height it will drive upwards when you press the Down button While running to a memory position the display will show GO1 GO2 or GO3 and when it stops in the stored position the height of the desk will be shown Releasing the UP or DOWN button will abort the memory drive The display will show the height of the desk Version with standard memory Press memory button 1 2 or 3 and the system will start driving to the wanted memory position K
40. x When the reference height is stored the digits will be switched off for 1 sec and back on again Store Desk I User I 6 6 If the buttons are not activated for 15 sec the clock function will appear in the display It is not necessary to repeat the calibration when changing batteries Page 30 of 44 Adjusting the clock Example Action Display view 1 Press the clock button using a ball pen US time mode Changing time mode Press N or W 2 Press No vJ adjust hh 3 Press the clock button again to confirm hh 4 Press N or Wvo adjust mm 5 Press the clock button again to confirm mm Press the clock button again to confirm time mode using a ball pen 24hr mode European time mode is default can be changed to 12hr mode C4Hhr Flashing lehe Flashing 001 hh is flashing m OO ft Switches to PM if hh gt 11 PE m 801 mm is flashing m 838 The clock is now activated Troubleshooting WDPL If errors occur the error code appears in the display The error segment flashes 1 Hz Description of the error Troubleshooting Position lost Initialise Overload in upward direction Remove heavy objects from the desk Overload in downward direction Remove objects that prevent downwards operation Illegal push on key Release all buttons and activate valid bu

Download Pdf Manuals

image

Related Search

Controls/Handsets controls and settings

Related Contents

Foucault et la folie - Espace culture de l`université de Lille 1  DG834v2  Alginet tissus  - NComputing  ダウンロード - Fishtail Studio[フィッシュテイル・スタジオ]    Manual del Usuario - porta gfe  Installation Guide - Everest Refrigeration  小 彡へッ ドセッ ト 取扱説明書 ・ LSHP  Philips Bulb 929689883505  

Copyright © All rights reserved.
Failed to retrieve file