Home
User Advice - (118.63 KB , PDF) - Intertrade Security Distributors
Contents
1. MAKE THE GATE ALARM DELAYED GATE 1 ae LU 1 ee GDC Enter your PIN and push the key enter the digit 4 followed by the digit 1 then push the key The control panel will beep twice to confirm that the gate 1 alarm is delayed The default delay time is 4 minutes PDD Jw 78e Ju Wu Jw Enter your PIN and push the key enter the digit 2 followed by the digit 4 followed by the digit 1 then push the key The control panel will beep twice to confirm that the gate 1 alarm is delayed The default delay time is 4 minutes MAKE THE GATE ALARM DELAYED GATE 2 Ec cM VIRILI Enter your PIN and push the amp key enter the digit 4 followed by the digit 2 then push the key The control panel will beep twice to confirm that the gate 2 alarm is delayed The default delay time is 4 minutes CDCI CD COD FD PDC QED Enter your PIN and push the key enter the digit 2 followed by the digit 4 followed by the digit 2 then push the key The control panel will beep twice to confirm that the gate 2 alarm is delayed The default delay time is 4 minutes BYPASS THE GATE ALARM GATE 1 amp 2 UC 0C C 28 amp Enter your PIN and push the key then push the key The control panel will beep 3 times and the GATE ALARM and GATE 1 amp 2 lights will start flashing slowly to confirm that the gate 1 amp 2 alarms are bypassed To cancel the bypass repeat the
2. digit 2 followed by the digit 2 then push the key The control panel will beep 3 times and the GATE ALARM and GATE 2 lights will start flashing slowly to confirm that the gate 2 alarm is bypassed To cancel the bypass repeat the same sequence of keys TURN THE GATE CHI ME ON OFF GATE 1 amp 2 Push the key then push the key The control panel will beep twice to confirm that the gate chime is turned off and three times if it s turned on If the chime is on the control panel will beep twice if gate 1 or 2 closes and three times if it opens Push the key enter the digit 2 then push the key The control panel will beep twice to confirm that the gate chime is turned off and three times if it s turned on If the chime is on the control panel will beep twice if gate 1 or 2 closes and three times if it opens TURN THE GATE CHI ME ON OFF GATE 1 Push the key enter the digit 1 then push the key The control panel will beep twice to confirm that the gate chime is turned off and three times if it s turned on If the chime is on the control panel will beep twice if gate 1 closes and three times if it opens 06 2098 206 7 Push the key enter the digit 2 followed by the digit 1 then push the key The control panel will beep twice to confirm that the gate chime is turned off and three times if it s turned on If the chime is on the control panel will beep twice if gate 1 closes and
3. same sequence of keys edic a Enter your PIN and push the key enter the digit 2 then push the key The control panel will beep 3 times and the GATE ALARM and GATE 1 amp 2 lights will start flashing slowly to confirm that the gate 1 amp 2 alarms are bypassed To cancel the bypass repeat the same sequence of keys MERLIN Electric Fence Control Panel User Manual BYPASS THE GATE ALARM GATE 1 ae ee ae ee e Enter your PIN and push the key enter the digit 1 then push the key The control panel will beep 3 times and the GATE ALARM and GATE 1 lights will start flashing slowly to confirm that the gate 1 alarm is bypassed To cancel the bypass repeat the same sequence of keys WIR JA JA 2 79 Ju Jw 7 Enter your PIN and push the key enter the digit 2 followed by the digit 1 then push the key The control panel will beep 3 times and the GATE ALARM and GATE 1 lights will start flashing slowly to confirm that the gate 1 alarm is bypassed To cancel the bypass repeat the same sequence of keys BYPASS THE GATE ALARM GATE 2 CUL UC UC Enter your PIN and push the key enter the digit 2 then push the key The control panel will beep 3 times and the GATE ALARM and GATE 2 lights will start flashing slowly to confirm that the gate 2 alarm is bypassed To cancel the bypass repeat the same sequence of keys JU UC JC 78 76 DRO Enter your PIN and push the key enter the
4. the key The control panel will beep twice and the GATE ALARM and GATE 1 lights will start flashing very slowly every 5 seconds to confirm that the gate 1 alarm is immediate MAKE THE GATE ALARM I MMEDI ATE GATE 2 ea Xu 7g Je UE J Enter your PIN and push the key followed by the digit 7 followed by the digit 2 then push the key The control panel will beep twice and the GATE ALARM and GATE 2 lights will start flashing very slowly every 5 seconds to confirm that the gate 2 alarm is immediate C JUL UC 267 e Je e e Enter your PIN and push the key enter the digit 2 followed by the digit 7 followed by the digit 2 then push the key The control panel will beep twice and the GATE ALARM and GATE 2 lights will start flashing very slowly every 5 seconds to confirm that the gate 2 alarm is immediate 3 MERLIN Electric Fence Control Panel User Manual MAKE THE GATE ALARM DELAYED GATE 1 amp 2 We NE e u Jw Enter your PIN and push the key enter the digit 4 then push the key The control panel will beep twice to confirm that the gate 1 amp 2 alarms are delayed The default delay time is 4 minutes Wu ld we We C a Enter your PIN and push the key enter the digit 2 followed by the digit 4 then push the key The control panel will beep twice to confirm that the gate 1 amp 2 alarms are delayed The default delay time is 4 minutes
5. three times if it opens MERLIN Electric Fence Control Panel User Manual TURN THE GATE CHI ME ON OFF GATE 2 Push the key enter the digit 2 then push the key The control panel will beep twice to confirm that the gate chime is turned off and three times if it s turned on If the chime is on the control panel will beep twice if gate 2 closes and three times if it opens Push the key enter the digit 2 followed by the digit 2 then push the key The control panel will beep twice to confirm that the gate chime is turned off and three times if it s turned on If the chime is on the control panel will beep twice if gate 2 closes and three times if it opens BYPASS THE SERVI CE ALARM 4X 4X 7 7 Ww 7g NE J Enter your PIN and push the key enter the digit 9 then push the key The control panel will beep 3 times and the SERVICE ALARM light will start flashing slowly to confirm that the service alarm is bypassed To cancel the bypass repeat the same sequence of keys STANDBY BATTERY TEST x 6 e Push the key enter the digit 6 then push the key The control panel will beep twice and start testing the battery The default battery test duration is 5 minutes CHANGI NG A USER PIN ou ou oU cU ew Cae Master PIN Ce User 1 6 ae WE ae CN New PIN WE IW Ge Ge New PIN Enter your master PIN push the key enter the digit 0 then push the key Enter the user num
6. LOW Service alarm is SERVI CE BYPASS FLASH switched off ALARM MEMORY ON ON ON Old alarm condition NEMTEK GROUP OUTLETS RANDBURG EDENVALE Tel 27 0 11 462 8283 Tel 27 0 11 453 1970 Fax 27 0 11 462 7132 Fax 27 0 11 453 1858 Web site http www nemtek com E mail nemtek nemtek co za MANUFACTURED IN SOUTH AFRI CA
7. NEMTEK qs GROUP OF COMPANIES MERLI N M SERI ES Electric Fence Control Panel USER MANUAL FENCE GATE SERVICE DUAL ZONE M28 M25 MERLIN Electric Fence Control Panel User Manual SWITCH THE FENCE ON OFF ee See WS Ce To switch the fence On or Off enter your four digit PIN followed by the key The control panel will beep twice to confirm that the fence is off and three times when the fence is turned on e If the red ON light is lit or flashing the fence is energized e Don t pause for more than 5 seconds while entering the digits or the control panel will reject your PIN number e f you make a mistake while entering your PIN press the key and start again e An incorrect PIN will cause the control panel to beep 5 times e The default master PIN is 1 2 3 4 AFTER AN ALARM OCCURS GNU NE EU a Cae Enter your PIN and push the key This will silence the buzzer and siren It will not switch the fence off One of the ALARM lights will flash or stay lit to indicate the type of alarm Investigate the cause of the alarm and correct it After the ALARM light stops flashing enter your PIN and push the key to clear the alarm memory CHANGE THE VOLTAGE ON THE FENCE uL UNA ZW e Enter your PIN and push the key enter the digit 3 then push key The control panel will beep three times to confirm the fence is in low voltage mode When the fence is on and in low voltage mode the red ON light w
8. ber 1 6 and push the key User number 1 is the master PIN Enter that user s new PIN and push the key Enter the new PIN again and push the key If the new PIN is accepted the control panel will beep twice If you make a mistake while programming or if the system rejects the new PIN the control panel will beep five times The default master PIN is 12 3 4 KEY DEFINITIONS ue ee ee Four digit Personal Identification Number PIN MERLI N Electric Fence Control Panel User Manual WHAT THE LIGHTS MEAN Condition Power On Gate Service Good Fence Renan Light Light Light Light Light Light FENCE GOOD ON ON OFF OFF aaa opp Fence on working FLASH properly FENCE OFF ON OFF OFF OFF OFF Opr Fence off working properly MAINS FAI LURE OFF System on battery power SLOW BATTERY LOW FLASH Check mains supply SLOW SLOW FAST Check mains call for BATTERY FLAT FLASH FLASH FLASH service SLOW Check fence for FENCE CHECK FLASH OFF OFF vegetation FENCE CHECK ON OFF ofr Check fence for vegetation FENCE ALARM OFF FAST Problem on fence FLASH SLOW Fence in low voltage FENCE LV MODE FLASH mode SLOW Fence alarm switched FENCE BYPASS FLASH off FAST i GATE OPEN FLASH Gate is open SLOW Gate alarm is GATE BYFASS FLASH switched off INSTANT GATE PULSE Instant gate alarm 5 SEC g FAST i SERVI CE ALARM FLASH Call for service S
9. he control panel and the energizer unit will still be active UN BYPASS THE SI REN AND STROBE LI GHT ied EU Enter your PIN and push the key enter the digit 7 then push the key The control panel will beep twice to confirm that the siren and strobe light is NOT bypassed MAKE THE GATE ALARM I MMEDI ATE GATE 1 amp 2 Y YV COD CO B CD amp Enter your PIN and push the key followed by the digit 7 then push the key The control panel will beep twice and the GATE ALARM and GATE 1 amp 2 lights will start flashing very slowly every 5 seconds to confirm that the gate 1 amp 2 alarms are immediate X Ie J wv OD J Enter your PIN and push the key enter the digit 2 followed by the digit 7 then push the key The control panel will beep twice and the GATE ALARM and GATE 1 amp 2 lights will start flashing very slowly every 5 seconds to confirm that the gate 1 amp 2 alarms are immediate MAKE THE GATE ALARM I MMEDI ATE GATE 1 a Se or 7 We y Enter your PIN and push the key followed by the digit 7 followed by the digit 1 then push the key The control panel will beep twice and the GATE ALARM and GATE 1 lights will start flashing very slowly every 5 seconds to confirm that the gate 1 alarm is immediate Ge E WP GN ON CLAN UND Enter your PIN and push the key enter the digit 2 followed by the digit 7 followed by the digit 1 then push
10. ill flash The red ON light will stay lit if the fence is in high voltage mode BYPASS THE FENCE ALARM ZONE 1 amp 2 M WE WE ND Mw m A Enter your PIN and push the key enter the digit 1 then push the key The control panel will beep 3 times and the FENCE ALARM and ZONE 1 amp 2 lights will start flashing slowly to confirm that zone 1 amp 2 are bypassed To cancel the bypass repeat the same sequence of keys BYPASS THE FENCE ALARM ZONE 1 e Liu Wu Ww J Enter your PIN and push the key enter the digit 1 followed by the digit 1 then push the key The control panel will beep 3 times and the FENCE ALARM and ZONE 1 lights will start flashing slowly to confirm that zone 1 is bypassed To cancel the bypass repeat the same sequence of keys BYPASS THE FENCE ALARM ZONE 2 CODCOD COD CO FDTD BD Enter your PIN and push the key enter the digit 1 followed by the digit 2 then push the key The control panel will beep 3 times and the FENCE ALARM and ZONE 2 lights will start flashing slowly to confirm that zone 2 is bypassed To cancel the bypass repeat the same sequence of keys MERLIN Electric Fence Control Panel User Manual BYPASS THE SI REN AND STROBE LIGHT SILENT ALARM EXC Ue de I ae Enter your PIN and push the key enter the digit 4 then push the key The control panel will beep 3 times to confirm the siren and strobe light is bypassed The beeper in t
Download Pdf Manuals
Related Search
Related Contents
ONKYO C-733 User`s Manual - Mr Handsfree Manuel d`installation 1 GY-LS300CH 取扱説明書 追加変更のお知らせ Operating Instructions Sunrise Medical P120 User's Manual SikaFix® Kit fx9860G_Slim_Hard - Support RCA RCRBB04GR User's Manual Pavimentos laminados Pergo Copyright © All rights reserved.