1. l Plunger Knob T Screw Lock T Screw Railing with the hand till the Plunger lock 1 will place on the locking slot the Plunger lock 1 with one hand amp hold the Railing with the other hand Place the Railing downward completely till it rests on the bed Collapsible Type Safety Side Rails with S S Tubes i e Clamp nn 3 Plu L T Screw nger Knob Lock __ T Screw _1 1 Tolock the Railing pull up the Railing with the hand till the Plunger lock 1 will place on the locking slot 2 Tounlock the Railing Pull out the Plunger lock 1 with one hand amp hold the Railing with the other hand Place the Railing downward completely till it rests on the bed Safety side rails shoul dbe fitted and properly secured by atrained technician A Always use the Safety Rails with the mattress of the correct size which is approved for use with this bed for the safety of the patient Donotuse the safety side rails to move or lift the bed TF Cx Series UserManual Rev No 0 Date 23rd Jar 2015 17 Although the safety side railings have been designed to reduce the risk of patient injury the potential exists for patient entrapment particularly in agitated or disoriented patients patients who have cognitive disability or have uncontrolled body movement as well as patients who lack the physical st
2. FootBoards e The foot board is located at the foot end of the bed frame e The foot board protects the patients during transport and room docking e The Foot board can be removed or attached in a single step by extending the equal force with both the hands inthe bracket by ensuring the proper matching of the brackets with board holder fitted on the main frame A Do not hang any heavy items on the Head amp Foot Board Pushing Pulling the Bed from the Head amp Foot Boards may cause play in the Head Foot Board mounting brackets in the long run ES To facilitate easy movement of Overbed Table over the Bed The Conventional and S S Laminated Bows at Foot End are designed with low height The Polymer Moulded Bow at Foot End has to be removed Safety Side Rail Options Swing Down Type Safety Side Rails HH 1 To lock the Railing pull the Railing upwards by extending equal force with both the hands On pulling the Railing completely upwards the Lever 1 will lock the Railing 2 To unlock the Railing pull the Lever 1 with one hand 8 hold the Railing with the other hand On releasing the Lever place the Railing downward TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 Collapsible Type Safety Side R 1 Tolockthe Railing pull up the 2 Tounlock the Railing Pull out ails u s 2
3. Cx4000B Cx4000C Beds User s Manual Index 10 Introduction About this Product Definitions Safety Environmental Specifications Installation Optional Accessories Operation Maintenance amp Cleaning Warranty 8 Service TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 01 01 03 03 04 05 08 12 19 23 INTRODUCTION Aboutthis User Manual This This kind User Manual contains instructions for the proper and safe use of Cx4000B Cx4000C Bed Series Beds and for patient amp user safety and comfort which has to be strictly followed User Manual has to be read and followed by every person using or handling this Bed In case of any query y contact Janak Healthcare Pvt Ltd ABOUT THIS PRODUCT Cx4000B Cx4000C ICU Bed Features These Cx4000B Cx4000C Bed are non invasive medical devices used for resting and treatment of the patients by medical paramedical hospital personnel to help and support the patient in diagnosis prevention monitoring treatment or alleviation of the disease These Cx4000B Cx4000C Bed are patient support and patient rest facility which help medical personnel in carrying out their medical procedures comfortably minimizing the risks while moving and handling the patient These Cx4000B Cx4000C Bed are manufactured and supplied in non sterile condition for use in normal hospital environment These Cx4000B Cx4000C
4. OPTIONAL ACCESSORIES I V Poles Product Specific at Sa cI y E 1 1 vr Heavy Duty I V Pole Utility Pole Telescopic I V Pole These are used to hang I V bags for infusion of liquid substances directly into the vein of patient occupying the bed Do not exceed the load capacity of 20 kgs max Equally distributed on all hooks per I V pole as damage to I V Pole due to overloading may result in personal injury or equipment damage TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 S S Lifting Pole 0553 S S Lifting Pole helps the patient lying on the Bed to lift themselves up on their own by holding the hand grip Moulded Chart Holder 0158A Orthopaedic Traction Pulley 0187 0187A Molded Chart Holder is normally hung on the Foot Board outer side and facilitates placing of patient related documents TF Cx Series UserManual Rev No 0 Date 23rd Jan 2015 Orthopedic Traction Pulley is used in treatment of orthopedic conditions like Prolapsed Lumbar Intervertebral Disc Slipped Disc Oxygen Cylinder Cage 0166 Oxygen Cylinder Cage is placed on the Base Frame of the Bed and used to hold the oxygen cylinder Urine Bag Holder 0156 Urine Bag Holder is u
5. Bed are manually operated to provide clinical positions with the help of Screw Mechanisms These Cx4000B Cx4000C Bed are not diagnostic measuring monitoring or a therapeutic device or we say hat it can prevent or alleviate disease These Cx4000B Cx4000C Bed are also useful for intensive care critical care in hospitals and nursing homes CF Please refer Cx4000B Cx4000C catalogues for salient features of these products Technical Data ECF Please refer Cx4000B Cx4000C catalogues for Technical Data of these products Opt ional Accessories EF Please refer Cx4000B Cx4000C catalogues for various accessories available and compatible with these products TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 a JANAK HEALTHCARE Cx 4000B Cx4000C Bed Variants In this Bed Series there are four Screw Mechanisms used to attain the clinical positions of Backrest Upper Leg Height amp Trendelenburg Reverse Trendelenburg This bed is available with removable Head amp Foot boards and 125 mm high grade synthetic castors with two diagonally positioned brakes Cx4000B variant is available with M S top Cx4000C variant is available with M S top 1 1 7 TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 DEFINITIONS Operator Operator is the person appointed by the owner i e clinic hospital management etc wh
6. law and notwithstanding the failure of the essential purpose of any limited remedies In order to maintain functional safety and right to claim under the warranty only original replacements parts may be used For ordering replacement parts customer service request and further question please contact our technical support department DISCLAIMER Every effort has been made to ensure that the informationin this user manual is valid Janak Healthcare Pvt Ltd reserves the right to change the information in this document without prior notice MANUFACTURER S ADDRESS Corporate Office Janak Healthcare Pvt Ltd Unit No 12 1st Floor Kalpataru Point Opp Cinemax Theatre Sion Circle Sion E Mumbai 400022 Tel 91 22 4915 3000 Fax 91 22 4915 3100 www janakhealthcare com Registered Office Janak Healthcare Pvt Ltd Janak House Opp Indian Oil Corp Depot Sheikh Misry Road Wadala E Mumbai 400037 Tel 91 22 2412 0171 2413 0407 Fax 91 22 2413 9870 Toll Free No 1800 22 8020 Email technicalsupport janakhealthcare com ce TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 23 24 Notes TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 Notes TF MB Cx Series U
7. 0C M S Collapsible Safety Side Railings L T Screw Si Clamp Plunger Knob T Screw Loosen the two T Screws provided below the clamp e Fix the Safety Side Railings to the sides of the Bed frame and tighten both the T Screws By holding the Safety Side Railing with both the hands pull out the Plunger Knob and push the Safety Side Railing inside e Press the S S Rod with both the hands and lower the Safety Side Railings for few cycles to check smooth operation of the Safety Side Railings TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 3 0358 ForCx4000B Cx4000C Collapsible Safety Side Railings with S S Tubes e Clamp 3 Fr 0 Aj Plunger Knob _ 48 T Screw e Loosen the two T Screws provided below the clamp e Fix the Safety Side Railings to the sides of the Bed frame and tighten both the T Screws e By holding the Safety Side Railing with both the hands pull out the Plunger Knob and push the Safety Side Railing inside e Press the S S Rod with both the hands and lower the Safety Side Railings for few cycles to check smooth operation of the Safety Side Railings Head amp Foot Boards e Fix Head and Foot Board by extending equal forces with both the hands in the bracket TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 5
8. ECIFICATIONS Usage Storage and Transport Temperature 10 C to 50 C Relative Humidity 0 to 95 non condensing Atmospheric Pressure 800 to 1060 hPa Altitude lt 2000m TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 INSTALLATION 1 Unpackallthe components carefully 2 Ifthe packing is drenched by rain water or other liquids inform this matter to the operator 3 Each Bedis supplied with the following components as per packing list Bed fitted with castors and Screw Mechanism Rubber Buffer with bush Removable Head amp Foot Board Product specific Safety Side Railings Product Specific Polymer Moulded Handle Miscellaneous Items 1No 4Nos 2Nos 1 Set 1No 1 Packet 4 Notify if any damage has occurred during transportation either to the authorized agent or directly to Janak Health Care Pvt Ltd A Installation ofthe Bed should be done only by Janak trained technicians Rubber Buffers Buffer e Fix the rubber buffer in the buffer holder with bush and bolt at all 4 corners TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 lt a JANAK HEALTHCARE 1 0354 For Cx4000B Cx4000C Full length Swing Down Type Safety Side Railings 4 Er This railing comes factory fitted to Bed Lever O y Fri 2 0356A For Cx4000B Cx400
9. and approved for use with the Bed e Ensure that the Bed is assembled and installed in accordance with the instructions given in this User Manual Restrict child visitors without proper attendants Supervision is necessary to avoid any mishap due to unintended movement ofthe Bed e Persons with reduced physical or mental abilities 8 children must not be allowed to use amp handle the Bed without proper supervision Donotallow any visitor to sit on the Bed as it may cause overloading Refer section Operation e Accessories or any devices used along with the Bed should be as per its intended use specified and approved by Janak Healthcare Pvt Ltd e The Bed should always be kept and used in normal indoor hospital environment Donotkeep any articles below the bed main frame It can damage the Linkages and Screw Mechanisms e Ensure that the bed is moved on a smooth stepless floor without any obstructions in its path to prevent any damage to the undercarriage of the bed e Keep some gap between walls and Bed while in stationary position and also while moving from one place to another e Keep the User Manual handy with the Operator User for ready reference Always use a mattress of the correct size and type with this bed Before operating the Bed make sure the patient is safely positioned on the mattress to avoid any inadvertent entrapment or imbalance A Use of water mattress is prohibited on this bed ENVIRONMENTAL SP
10. and not overloaded to avoid any personal injury or equipment damage gt TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 OPERATION e Before putting the Bed into use for the first time ensure that all the transport securing devices and packing film are removed e Clean and disinfect the Bed prior to the first time use e The Bed should be used on a flat floor The force required to move the Bed from one place to another with without patient may vary depending on the flooring conditions e Check ifall the operations are functioning properly This Bed should be operated only by an authorized and trained person who has knowledge of its operation A Donotload the Bed more than the Safe Working Load as mentioned above TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 Castors 8 Braking Mechanism Adjusting the Trendelenburg Reverse Trendelenburg Tilt Product Specific Trendelenburg Reverse Trendelenburg gt The Cx4000B Cx4000C Bed is equipped with four 125 mm High Grade Synthetic Castors two diagonally opposite castors are with brakes To lock the Castors press the latch andto unlock release the latch Adjusting Height Product Specific Height Adjustment To adjust the Height first insert the handle on the respective crank mechanism and turn the handle anti clockwise or clockwise to ra
11. anties shall not apply if the Product has been subjected to a physical abuse misuse abnormal use or use not consistent with Janak Healthcare Pvt Ltd s published directions b any modification by anyone other than Janak Healthcare Pvt Ltd or third parties designated by Janak Healthcare Pvt Ltd or c fraud tampering negligence or accidents depending upon the nature of the products Limitation Of Liability In no event shall Janak Healthcare Pvt Ltd be liable or obligated to the end user in any manner for any special non compensatory consequential indirect incidental statutory or punitive damages of any kind including without limitation for injury or loss of life lost profits lost sales lost revenue loss of any software or data or loss of use of any hardware software or data regardless of the form of action whether in contract tort negligence strict product liability or otherwise even if Janak Healthcare Pvt Ltd has been informed of or is aware of the possibility of any such damages in advance Janak Healthcare Pvt Ltd s total aggregate liability under this agreement and in relation to anything which Janak Healthcare Pvt Ltd has done or not done in connection with this agreement shall be limited to the price of the products purchased and paid for by the end user during the period in which such liability arises The limitations set forth above shall be deemed to apply to the maximum extent permitted by applicable
12. astening Damage Missing Sign Result of inspection Date TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 21 22 Trouble Shooting Guide Problem Possible Causes Remedy Castors not working e Castors are damaged e Replace the Castors Castors are not locking e Check the Locking Lever for any damage 8 replace the Castor Abnormal sound vibrations during any operation Linkages are tight e Lubricate the Linkages from its joints Nut Bolts are loosened Tighten the bolts Railing not locking in raised position 0360 Gas Spring is not working due to Oil leakage 0354B check the locking lever and the locking spring tension 0356B Check plunger knob and hole alignment plunger knob broken plunger knob spring defective e Check amp replace the Gas Spring e Replace the lever spring Replace plungerknob spring Screw Mechanism not working Mechanism is jam very tightto rotate Mechanism is bent or broken e Check do little oiling or greasing e Replace the screw mechanism TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 WARRANTY amp SERVICE Janak Healthcare Pvt Ltd warrants solely to the end users of this product that for a period specified in the warranty certificate such product shall perform as per its intended use The foregoing warr
13. ise or lower the height respectively Remove the handle and keep it safely under the mattress TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 To adjust the Trendelenburg position or Reverse Trendelenburg position first hold the main frame firmly with one hand and insert the handle into the respective crank mechanism as shown in the figure above Raise or lower the frame by rotating the handle to the desired tilt position Remove the handle and keep it safely under the mattress Adjusting Backrest 1 Backrest 1 Adjusting Br To adjust the Backrest first insert the handle on the respective crank mechanism and turn the handle anti clockwise or clockwise to raise the Backres respectively Remove the handle and keep it safely under the mattress Adjusting the Legrest Section Product Specific 7 Legrest Adjusting To adjust the legrest section first insert the handle on the respective crank mechanism and turn the handle anti clockwise to lower or clockwise to raise the leg rest section respectively Remove the handle and keep it safely under the mattress To attain the Calf Elevation position the Lower Leg Section can be adjusted manually Lower Leg Section Product Specific Lower Leg Section gets raised simultaneously when raising the Upper Leg Section through electrical control To attain the Calf Elevation position
14. ng the upper sections of the Bed amp work along all horizontal surfaces Work methodically towards the lower sections of the Bed Take extra care to clean areas that may trap dust or dirt All detachable accessories and its component can be cleaned separately Do not expose the Bed to excessive moisture as corrosion may cause personal injury or equipment damage Disposal Product and its defective parts especially elements made of plastic steel and rubber material should be disposed off in accordance with the statutory rules and regulations prevailing for such disposal The user is advised to contact Janak Healthcare Pvt Ltd for further assistance TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 JANAK HEALTHCARE Routine Inspection Check List Inspection By The User Recommended Freguency Every new allotment but not later than one month Checks Observation OK Description of faults Visual check of the mechanical components Main Frame Damage Deformation Rod with Clamp Optional Damage Bent Mattress Damage Screws and Rivets Performance check of all mechanical Loosened Missing components Screw Mechanism Smooth movement Detachable Head amp Foot Boards Secure retention Castors Locking Release mobilization Safety Side Railings Locking Un locking Secure fastening Legrest Accessories Engagement F
15. nt free indoor environment on a flat surface with gradient not more than 5 degrees the Bed is not in use for long term it is necessary to conduct a test to check for functioning and any mechanical damage that may have been caused Depending on the usage certain moving parts may require replacement due to wear amp tear We recommend imely replacement with original spares for safety and trouble free operation TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 20 Cleaning 8 Disinfecting The Bedis not suitable for machine wash or steam cleaning Do not use water jet for cleaning The Bed cannot tolerate the influence of strong solvent basic or alkaline liquids amp caustic agents The cleaning agents must not contain any substances which bring about any change in the structure or adhesive property of the plastic The Bed should be properly cleaned and disinfected to avoid infection and stains before allotment to a new patient Immobilize the Bed amp remove all the detachable accessories and components before cleaning Any prolonged contact of urine or acid on mild steel can corrode the surface Keep the surface dry at all times Wearing suitable protective clothing clean the surface with a disposable cloth soaked in a neutral detergent and hot water We recommend use of approved disinfectant and cleaning agents to clean the Bed e g Bacillocid or other similar agents Start by cleani
16. o will be responsible for the safe operation of this Bed User User is a person who is capable of assessing clinical condition of patient e g specialist medical personnel doctors nursing staff attendants etc On the basis of their training experience or through the instructions they are entitled to operate the Bed on their own responsibility or to carry out work on it and are able to recognize and control possible risks to the patient as well as the Bed Patient The patient is a person who is ill infirm disabled or in need of care amp occupying this Bed Each time the Bed is allotted to a new patient it is recommended that the patient is instructed by the operator or the user about the functions important for his her comfort and safety SAFETY Inthis User Manual the following safety symbols are used a Danger This symbol will appear wherever safety instructions are designed to protect people from physical harm The symbol stands for imminent danger of death or serious injury A Caution This symbol will appear where situations are described which might be dangerous and which might inflict slight injuries U Advice This symbol will appear in front of additional helpful pieces of advice Adotin front of the text implies the action that is required to be taken TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 Safety Instructions Always use original accessories that have been designed
17. rength to extract themselves if they get entrapped Users should carefully evaluate the need for safety side rails and periodically check patients in accordance with facility protocols for safe positioning The Safety Side Railings should always be in raised position when attaining lowest height position or when attaining Trendelenburg Reverse Trendelenburg tilt positions If these safety measures are not observed injuries can be caused to hands knees fingers feet legs or other body parts of patient due to unintended and unintentional entrapment In children or weak patients who are less than 146 cms tall non observance of these guidelines may even lead to death TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 MAINTENANCE amp CLEANING Maintenance Each time before putting the Bed into service the user must check that All the functions are in satisfactory working condition before the Bed is allotted to the next patient Lubrication of all the mechanical joints pins moving parts tightening of the bolts should be carried out at east once in three months to avoid unnecessary sound and wear amp tear of the Bed At regular intervals carry out a visual inspection and check for any mechanical damage e g loose missing rivets screws etc any damage or malfunction is observed immediately report this matter to the operator the Bed is not in use it should be stored in a dry and rode
18. sed to hold the urine bag and is hung on any one side of the Bed Frame Mattress Product Specific Any one type as per order Mattress is used for patient comfort Janak Healthcare Pvt Ltd recommends the use of original Mattresses that have been designed amp Tested specifically forthe Cx4000B Cx4000C Beds Ensure Mattress of correct size and firmness to eliminate gaps causing entrapment risk prevent accidental roll over events in case of low height of railing and safe patient transfers in 8 out ofthe bed Mattress impermeability could be affected by needle sticks Users should be instructed to avoid punctures caused by improper use of needle sticks Failure to do so could result in cross infection amp patient injury The mattress should be regularly inspected for punctures rips tears or other such damage 8 replaced with suitable original mattress if reguired gt py TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 Smoking should be prohibited near the mattress with without patient as this is a fire hazards and mattress sheets 8 pillows generally do not have flame retardant properties gt Use the Bed accessories in accordance with the manufacturer s instructions for patient safety and comfort Use recommended spares and accessories of suitable design manufactured by Janak Healthcare Pvt Ltd to eliminate hazards Ensure that the accessories are properly secured
19. serManual Rev No 0 Date 23rd Jan 2015 25 26 Notes TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 2 JANAK EALTHCARE JANAK HEALTHCARE PVT LTD Unit No 12 1st Floor Kalpataru Point Opp Cinemax Theatre Sion Circle Sion E Mumbai 400022 Tel 91 22 4915 3000 Fax 91 22 4915 3100 www janakhealthcare com
20. the Lower Leg Section can be adjusted manually TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 5 To Raise Leg Section Lower part Manually e Firmly hold and lift the Leg Section Lower part with one hand e With the other hand hold the Ratchet Handle to the required inclination e Place the Ratchet Handle in the desired Ratchet Notch to lock the position e Make the patient comfortable by readjusting his position on the Bed To Lower Leg Section Lower part Manually e Firmly hold the Leg Section Lower part with one hand e Pulloutthe ratchet handle from the Ratchet Notch to unlock the position e Carefully place the Leg Section Lower Part on the Main frame N Always observe the correct adjustment sequence e Care should be taken to avoid fingers and hand getting entrapped between the Ratchet and the top frame Head amp Foot Boards Removable Type Head Boards p 0181 Conventional Bow 0183 Polymer Moulded Bow e 56 head board is located at the head end of the bed frame The head board can be removed or attached in a single step by extending equal force with both the hands in the bracket by ensuring the proper matching of the brackets with board holder fitted on the main frame Thehead board can be removed for the ease of access to the patient from head side TF MB Cx Series UserManual Rev No 0 Date 23rd Jan 2015 18

Download Pdf Manuals

image

Related Search

Related Contents

Installation and operating instructions concentric  instructions to authors for the preparation of - Industrial-EKG  Magnese MA-204026W  Outillage de pose - Electrocomponents  Hardware Manual - RTD Embedded Technologies, Inc.  Comunicación serie Zelio Logic Comunicación    

Copyright © All rights reserved.
Failed to retrieve file