Data Sheet DB EN IB IL 24 DI 16-ME

image

Contents

1. Definition of switching thresholds Maximum low level voltage Minimum high level voltage Common potentials Nominal input voltage Uj Permissible range Nominal input current for UIN Delay time Permissible cable length to the sensor Use of AC sensors IB IL 24 DI 16 ME 16 According to EN 61131 2 Type 1 UL max 5v Unmin gt 15 V Segment supply ground 24 V DC 3 V Uy lt 30 V DC 3 mA minimum None 30 m to ensure conformance with EMC directive 89 336 EEC AC sensors in the voltage range lt Uyy are limited in application corresponding to the input design Characteristic Curve Current Depending on the Input Voltage and the Ambient Temperature TA Supply Input Current Voltage 18 V 24 V 30 V Input Current for t gt 20 s For Ta 25 C For Ta 55 C 2 9 mA 2 5 mA 3 8 mA 3 5 mA 4 2 mA 3 0 mA The current is reduced depending on the ambient temperature T4 and the number of inputs that are switched on internal terminal temperature Power Dissipation Formula to Calculate the Power Dissipation of the Electronics 16 Prop 0 525 W X Un x 0 003 A n 1 Where Pro7 Total power dissipation in the terminal n Index of the number of set inputs n 1 to 16 Uinn Input voltage of input n Power dissipation of the housing Phou Limitation of Simultaneity Derating Derating Safety Equipment Overload in segment circuit Surge voltage Polarity reversal 7444 en 00 2 8 W maximu
2. 1 Local diagnostic and status indicators Function Identification Dark blue 4 14 2 4 3 4 4 4 5 4 64 7 4 8 4 4 ee lee eoeci 1444A002 Figure 2 Terminal point numbering Local Diagnostic and Status Indicators D Green Diagnosis For Each Connector 1 2 3 4 Status indicators of the inputs Terminal Assignment per Connector Signal input IN Segment voltage Us for 2 and 3 wire termination S Ground contact GND for 3 wire termination Signal input IN PHOENIX CONTACT 5 7444 en 00 IB IL 24 DI 16 ME Internal Circuit Diagram Local bus U 7444A006 Figure 3 Internal wiring of the terminal points Protocol chip bus logic including voltage conditioning Other symbols used are explained in the IB IL SYS PRO UM E user manual or the system LED Key manual for your bus system x Optocoupler d Digital input Electrically isolated area 7444 en 00 PHOENIXCONTACT 6 IB IL 24 DI 16 ME Connection Notes and Connection Example N Please note that the terminal must be provided with supply voltage Us as it is used internally as the auxiliary supply When connecting the sensors observe the assig
3. IB IL 24 DI 16 ME Inline Terminal With 16 Digital Inputs SS 4 S d i AUTOMATIONWORX 70 Data Sheet 7444 en 00 PHOENIX CONTACT 11 2006 7444001 Description The terminal is designed for use within an Inline station It is used to acquire digital input signals Features Connections for 16 digital sensors Connection of sensors in 2 and 3 wire technology Maximum permissible load current per sensor 250 mA Maximum permissible load current from the terminal 4 0 A A Diagnostic and status indicators 35 This data sheet is only valid in association with the IB IL SYS PRO UM E user manual or the Inline system manual for your bus system 35 Make sure you always use the latest documentation It can be downloaded at www download phoenixcontact com A conversion table is available on the Internet at www download phoenixcontact com general 7000 en OO pdf D OGD OO GD GD 0 GD OO 05 Likontacr 0 GDC INSPIRING INNOVATIONS Ordering Data Products Description Terminal with 16 digital inputs including connectors with consecutive numbering and labeling fields Documentation Description Configuring and Installing the INTERBUS Inline Product Range user manual Accessories Description Terminal for potential distribution 24 V including connector and labeling field Terminal for potential distribution GND including connector and labeling field Technical Data Genera
4. l Data Order designation Order No Housing dimensions width x height x depth Weight Operating mode Transmission speed Connection method for sensors Permissible temperature operation Permissible temperature storage transport Permissible humidity operation storage transport Permissible air pressure operation storage transport Degree of protection Protection class Interface Local bus Power Consumption Communications power Current consumption from the local bus Power consumption from the local bus Segment supply voltage Us Nominal current consumption at Us Type Order No IB IL 24 DI 16 ME 2897156 Type Order No IB IL SYS PRO UME 2743048 Type Order No IB IL PD 24V PAC 2862987 IB IL PD GND PAC 2862990 IB IL 24 DI 16 ME 2897156 48 8 mm x 120 mm x 71 5 mm 122 g without connectors Process data mode with 1 word 500 kbaud 2 and 3 wire technology 25 C to 55 C 25 C to 85 C 10 to 95 according to DIN EN 61131 2 70 kPa to 106 kPa up to 3 000 m above sea level IP20 according to IEC 60529 Class 3 in acc with VDE 0106 IEC 60536 Via data routing 7 5V 60 mA maximum 0 45 W maximum 24 V DC nominal value 4 A maximum Supply of the Module Electronics and I O Through Bus Terminal Power Terminal Connection method 7444 en 00 Through potential routing IB IL 24 DI 16 ME Pcs Pck 1 Pcs Pck 1 Pcs Pck 1 PHOENIXCONTACT 2 Digital Inputs Number Input design
5. m within the permissible operating temperature No limitation of simultaneity no derating No Protective elements of the power terminal Protective elements of the power terminal PHOENIX CONTACT 3 IB IL 24 DI 16 ME Electrical Isolation Isolation of the Voltage Areas To provide electrical isolation between the logic level and the I O area it is necessary to supply the station bus terminal and the digital input terminal described here via the bus terminal or a power terminal from separate power supply units Interconnection of the power supply units in the 24 V area is not permitted See also user manual Common Potentials The 24 V main voltage 24 V segment voltage and GND have the same potential FE is a separate potential area Separate Potentials in the System Consisting of Bus Terminal Module Power Terminal and I O Terminal Test Distance Test Voltage 5 V supply outgoing remote bus 7 5 V supply bus logic 500 V AC 50 Hz 1 min 5 V supply outgoing remote bus 7 5 V supply bus logic 500 V AC 50 Hz 1 min 7 5 V supply bus logic 24 V supply I O 500 V AC 50 Hz 1 min 24 V supply I O functional earth ground 500 V AC 50 Hz 1 min Error Messages to the Higher Level Control or Computer System None Approvals For current approvals please refer to www download phoenixcontact com 7444 en 00 PHOENIXCONTACT 4 IB IL 24 DI 16 ME Local Diagnostic and Status Indicators 7444A005 Figure
6. nment of the terminal points to the process data see page 9 IB IL 24 DI 16 ME IB IL PD 24V IB IL PD GND 7444A003 Figure 4 Typical sensor connections A 3 wire termination B 2 wire termination 7444 en 00 PHOENIXCONTACT 7 IB IL 24 DI 16 ME The sensors can also be connected via external busbars Ensure that the sensors and Us are supplied from the same voltage supply 35 Ensure that the Inline system ground is reference for at least the ground when using external busbars external 24 V external 7444A004 Figure 5 Typical connection of sensors when using external busbars 7444 en 00 PHOENIXCONTACT 8 IB IL 24 DI 16 ME Programming Data Configuration Data INTERBUS Other Bus Systems BEhex 190dec For the programming data of other bus Length code systems please refer to the corresponding Process data channel 16 bits electronic device data sheet GSD EDS Input address area 2 bytes Output address area Parameter channel PCP 0 bits Register length bus 2 bytes Process Data 35 For the assignment of the illustrated byte bit view to your INTERBUS control or computer system please refer to the DB GB IBS SYS ADDRESS data sheet Order No 9000990 For the assignment of the ill
7. ustrated byte bit view to control systems of other bus systems please refer to the AH IB IL 24 DI DO 16 ADDRESS document Order No 9014124 Assignment of the Terminal Points to the IN Process Data 35 The following table applies to the IB IL 24 DI 16 ME terminal with the original connector set Word bit Word 0 view w tw w m um u vo e s 7 e6 s 4 3 2 9 8yte bit view Byte 7 T A a EAS educ Terminal point 7 4 7 1 3 1 signal Terminal point 8 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 24 V Terminal point 8 3 7 3 6 3 5 3 4 3 3 3 2 9 1 3 GND Status indicator PHOENIX CONTACT 11 2006 7444 en 00 PHOENIX CONTACT GmbH amp Co KG 32823 Blomberg Germany 9 HE Phone 49 52 35 30 0 Fax 49 0 5235 3 4 12 00 www phoenixcontact com

Download Pdf Manuals

image

Related Search

Related Contents

  4K放送用フィールドズームレンズ UHD DIGISUPER 86 UJ  Manuale dell`utente di Symantec™ Deployment Solution 7.5 SP1  Manuale dell`utente (IT)  Mode d`emploi Béton Ciré  Trotec LD6000 Operating Manual  CH260, CH270, CH395, CH440 Manual del usuario  Uniden EXP4241 Owner's Manual  Nortel Networks 2300 Switch User Manual  Magnum ES42 Edge Switches Installation and User Guide  