DP-200M Quick Guide
Contents
1. For other advanced features please read User s Manual in provided Software CD Note for DP 200M Clinical owner and existing and registered users When you open the DP 200M Clinical software a Patient List window will display with default Activated Patient as Guest Blood pressure measurement CANNOT be saved for the Guest Find a patient name from the Patient List and double click to select it Perform blood pressure measurement as described above Note for Windows Vista 7 and 8 users If DynaPulse program doesn t run correctly use the Program Compatibility Wizard to change the compatibility settings or set DynaPulse program in Properties Compatibility via right click the mouse button on DynaPulse program icon and check select Compatibility Mode Run this program in Compatibility mode for Windows XP Service Pack 2 to resolve the issues 4 Part II DynaPulse online Hemodynamic Analysis Note A current and activated DAC DynaPulse Analysis Center account is required for uploading DP 200M Clinical data and performing DynaPulse online hemodynamic analysis Please contact us at www dynapulse com or call 760 842 8224 for more information Acquire DynaPulse Blood Pressure Data Make sure DP 200M Clinical is working properly do a BP measurement and save the data as described in Part I for a selected Patient If this patient has had BP already been measured and saved in DP 5200A P
2. 1 Quick Guide for DP 200M Clinical USB and Bluetooth compatible Congratulations and thanks for choosing the PC based DynaPulse 200M Clinical DP 200M non invasive blood pressure monitoring and recording system Part I Blood Pressure Measurement Before you start installing DP 200M Clinical hardware and software please check and make sure you have following items ready USB Bluetooth DP 200M Clinical monitor USB communication cable and Bluetooth dongle Blood Pressure cuff assembly Include 3 adult size cuffs AC DC adaptor or optional 4 AA batteries Not included in DP 200M package DP 200M Clinical software for Windows CD Include e Manual User s guide A PC with Windows operation system Windows 2000 XP Vista Win 7 or win 8 and a USB communication port Getting ready with DP 200M Clinical monitor and connect it to a PC Select a power source Plug in the supplied AC DC adaptor 110 Volts AC in USA or install 4 AA batteries into the battery compartment Connect Cuff assembly to DP 200M Use appropriate size cuff for each patient Connect USB cable one end to DP 200M and the other end to PC s USB port Make sure to install the USB driver for Windows System Equipment Layout Shown a Bluetooth DP 200M Clinical monitor battery operation connected with a cuff assembly and to a PC s USB communication port Install DP 200M Clinical software a CD or DVD CD dri
3. athway program go to next step Register a patient and login to DAC clinical server 1 Make sure your PC is online Java Plug in wais installed and Pathway software is open and a patient is added new patient and selected 2 From Main menu click on DAC gt Analysis 3 Check cDAC PulseMetric com is selected fill in your DAC account s User Name and Password and click Login 4 Select and click on a Patient Name 5 Click on Profile and input edit patient profile information Items with must be entered 6 Click Update Server gt OK and Update Local gt OK and Close Upload or Transmit Patient s new Data for Hemodynamic Analysis 1 Following the above Register a patient and login to DAC steps 1 4 check the patient has his her Registered box marked Yes 2 Click on Upload Data Wait for a message reporting success to appear 3 View and Print Hymodynamic Report Now the patient s DynaPulse BP data has been successfully uploaded to DAC server for hemodynamic analysis Only the registered DAC account and its authorized user provided with its User Name and Password can review or print the patient s hemodynamic profile via Internet through www dynapulse com and login to cDAC as described above Note DynaPulse hemodynamic analysis applies the proprietary Pulse Dynamics methodology of SS Chio s invention It analyzes the pulsation signal obtained from a cuff during routine blood pre
4. creen instructions to put on the cuff and pump up pressure and perform a blood pressure measurement For automatic multiple BP measurements select Cycle to set interval and the total numbers of measurements A successful measurement will display the measured Systolic Diastolic Heart Rate and Pulse waveform etc To keep this measurement go to File and select Save You may enter comments such as before or after lunch for this measurement 3 Blood Pressures Arterial pulse display Systolic Diastolic Mean Heart Rate Systolic Cursor position Mean Diastolic Cuff pressure icon icon icon at cursor position Measurement Timeline 20 30 sec If an ERROR window appears following the instruction go to Measure and adjusting the High or Low Range settings accordingly Click Start to start another measurement Other features for reviewing the recorded blood pressure data The Trend Display and Analysis Go to Options and select Show Trend Window a histogram display of previously recorded blood pressure data will be shown Select Analysis to perform a statistic analysis Go to Record in Main Menu and select Personal Info would allow you to input and record or edit general personal information Go to Record in Main Menu and select Record Table a tabulated display of previously recorded blood pressure measurement data will be displayed
5. o START a blood pressure BP measurement Press START button to begin a BP measurement If failed try again Press STOP to stop if needed BP measurement result display A successful BP measurement when completed readings of Systolic Diastolic and Heart Rate will be displayed automatically with JNC 7 Guideline BP Classifications Save a BP measurement In the BP result display screen press SAVE to save the measurement data After BP data saved use Back key to return to the App Main screen To Exit or Close the DynaPulse Press Back key from the Main screen will end the program and turn OFF the BT DynaPulse monitor Use Home key will exit the App but not end the program and turn OFF the monitor When use batteries always turn OFF the monitor to save power NOTE The BT DP200M supports both Bluetooth and USB communication protocols They allow original DynaPulse software installed in PC with Windows OS to run and measure BP When using old DP200M software it requires manually pump up the cuff pressure with T type cuff connector with pump ball New version DynaPulse DP200M Clinical software with features of Pathway has Auto pump capability
6. ssure measuring cycle from supra systolic to sub diastolic Severe arrhythmia irregular pulses and or artifacts due to arm movement miss place of a cuff etc which affects the accuracy of blood pressure measurement and provides abnormal pulse waveform can result with ERROR or No hemodynamic parameters calculated For further information and references on clinical studies and publications please check our web site www dynapulse com or contact us 5 Part III DynaPulse Android App Quick Guide Download DynaPulse App from Google Play at https play google com store apps details id com dynapulse amp feature nav_result t W251bGwsMSwxLDMsImNvbS5k eW5hcHVsc2UiXQ Install DynaPulse App and Run on an Android based Smart phone or Tablet App compatible with Android 2 3 or higher Set up and pairing Bluetooth 1 Always use the Android smart device Bluetooth Set Up feature to initiate and pairing with Bluetooth DynaPulse monitor The code for paring DynaPulse monitor is 0000 2 For some smart device users may also pair it from DynaPulse App by a Select and press Bluetooth setup button in DynaPulse App Main screen b Turn ON the BT DynaPulse monitor and Press Scan in DynaPulse Bluetooth setup page When found Serial Port Device or Unknown at first time will be displayed c Select the showed Serial Port Device or Unknown and it will go back to the DynaPulse App Main screen The Bluetooth is paired and ready to use T
7. ve is required Insert DP 200M Clinical software CD to CD DVD drive and closed Following the on screen instruction select correct Window version to install USB driver and DP 200M Clinical software for blood pressure measurement When use Bluetooth built in or dongle paring is required USB Cuff PC with Windows OS 2 Note Bluetooth pairing use code 0000 and select available COM 1 through COM15 for Outgoing port First time installation of DP 200M software an automatic COM check window will appear click Continue to find and select an available COM port A complete e Manual Manual or UsersManual file is included in the DP 200M Clinical CD Use MS Word and or PDF reader to open the e manual file provided in the CD You may print out a copy for future reference This manual provides detail instructions of using operating and the features of DP 200M Clinical the Pathway features Install Java Plug in software for access to www dynapulse com web site and DynaPulse Analysis Center DAC server for hemodynamic analysis Optional service available to DP 200M Clinical user with active DAC account only Contact us for more information Ready and getting start with a blood pressure measurement Go to Patient in Main Menu select Add for first time or a new user and input patient s Name and ID Go to Measure in Main Menu select Start and following the on s