1. You can use this table as a programming record PROGRAMMING USER CODES ASSIGNING EXTRA OPTIONS Each user code has several extra options which can be assigned when programming the code or at any time later In NORMAL USER CODE PROGRAMMING mode Exclude light is off you can do the following Program Keypad Codes see page 14 Program Radio Codes see page 63 Program Access cards see page 65 View radio signal strength see page 60 In EXTRA OPTIONS mode Exclude light is on you can assign several powerful functions to each user code See below To view and program the Extra Options 1 Select a User Code P201 P256E The Exclude light is OFF 2 Press EXCLUDE E 7he Exclude light turns ON The following Extra Options can now be changed 1E AREA 1 CODES Assign remove user codes to Area 1 By default all user codes are assigned to Area 1 2E AREA 2 CODES Assign remove user codes to Area 2 O User codes can be assigned to Area 1 Area 2 both areas or no areas An Area will not arm unless it has one or more zones assigned to it P45E P46E it a code is not assigned to any Area s the code can be used for special functions such as to trigger outputs 3E ARM ONLY User Codes 2 56 can be programmed to Arm but not Disarm the panel See page 14 4E CODE ONLY ARMING Enables selected user codes to allow code only arming Arming can then be done either with or without the
2. Zone 5 Qr Ness control panels are es supplied with 1 tolerance 2K2 Zone 4 L Metal Film end of line r resistors 2200 Ohms ro Colour code Red Red 2K2 Red Zone 3 LQ 2K2 Zone 9 Black Brown Brown SS 22 jZone2 pS 12V DC Power Zone 4 S _____ for detectors No AN DC Power for detectors etc NESS LCD Keypad 100 667 Maximum 3 keypads Up to 2 x Ness 12V Siren 100 172 OR 3 x 12V Screamer 100 238 100 004 Up to 3 x Horn Speaker 8 Ohm NOI 110 E Up to 2 x Strobe Light NOI 300 17V AC Red amp Black EARTH White Ness 17V AC Plug Pack 840 029 Australia only f required Zone Split can be enabled for Zones 1 8 This provides compatibility with previous versions of D16 which did not have physical zone inputs 9 16 Zone Split requires different resistor values for virtual zones 9 16 See Zone Split option page 34 EXTERNAL INTERNAL ALTERNATIVE 12V SIRENS 100 172 Ness 12V Internal Siren 100 238 Top Hat 12V Piezo Screamer 2 RESET act A STR at Sese ee 7 SIREN at 2004 Ness Security Products siren cover The terminal block should be mounted inside the STROBE LIGHT 01300 Ness Panel amp Noise KITS are supplied with the 100 238 Top Hat s
3. 9 5V 14V DC 12 volt 7 0 Amp hour Sealed Lead Acid Operating voltage Rechargeable battery Battery charging current 350mA maximum current limited Dynamic battery test Backup battery is tested under load hourly and on arming FUSOS e 2 Amp auto resetting Siren output amp Reset output 500mA auto resetting 12 volt auxiliary outputs 200 mA auto resetting strobe output 8 or 16 zone inputs 2 x 24hr tamper inputs 2200 Ohms 2K2 Also see Zone Split option for the D16 3 Multi pin connector for the Ness Radio Interface 100 200 Maximum keypads RADIO Header SERIAL Header Serial data port for direct connect programming using NessComms software READER Multi pin port for connecting up to 3 Ness proximity access card readers OUTPUTS e On board siren driver with timed output Maximum 3 x 8 Ohm horn speakers SODE m AAA AA 12V DC timed output Maximum 2 x 1 Watt strobe lights Reset eene 12V DC timed output Maximum 3 x 12V piezo screamers Equipment power output 13 8V DC output for powering detectors and other equipment Maxi mum 500mA AUX Header Multi pin connector provides outputs Aux1 Aux2 Aux3 Aux4 12V DC APPROVALS EMC COMPLIANCE EN 50130 4 1996 Part 4 Electromagnetic compatability Electrostatic Discharge Radiated RF Immunity Electrical Fast Tran
4. PROGRAMMING HEX CLIENT CODES Dialler client codes can now be entered in Hexadecimal Use the following keys to enter the hex digits B C D E or F HEX DIGIT KEY ENTRY DISPLAYED ON LCD DISPLAY B Key 11 ARM Key 12 D MONITOR Key 13 E EXCLUDE Key 14 F MEMORY key 15 TELEPHONE NUMBER 3 TEST CALLS Phone Number 3 is used to send Test Calls If it is not programmed then Test Calls are sent using Telephone No 1 amp 2 PROGRAMMING SEQUENCE P80E existing telephone number is displayed one digit at a time ENTER NEW TELEPHONE E new telephone number is displayed one digit at a time EXAMPLE To program Telephone No 3 to be 03 2468 1234 P80E0324681234E TELEPHONE NUMBER 4 CALLBACK Phone Number 4 is used to prevent unauthorised up download The panel will dial the callback telephone number to commence a NessComms up download session NessComms up download without callback is allowed by turning off option P9OE 8E PROGRAMMING SEQUENCE P81E existing telephone number is displayed ENTER NEW TELEPHONE No E new Telephone No 4 is displayed one digit at a time FOLLOW ME TELEPHONE NUMBER The Follow Me telephone number is only used in Audible Dialling mode If P86E SE 4E 5E or 6E are on The Follow Me telephone number can be programmed in User Program Mode If the Follow Me number is programmed then the primary amp secondary numbers are ignored IF P86E 3E or 4E ARE ENABLED AUDIBLE MONITORING If the
5. D16x ConTROL PANEL INSTALLATION MANUAL EA RE D S Security Products EM Pane NESS D8 CONNECTION DIAGRAM TELEPHONE LEAD Supplied za Connect to Mode3 socket B Lead shown is for Australia only N O TAMPER SWITCH 761 002 Colour BLACK Supplied with Ness siren covers ALTERNATIVE TAMPER SWITCH WIRING For N C Tamper Switches TAMPER SWITCH SWI920 Colour WHITE e cm H ame 2K2 68 a i a Fov E PE aL TELEPHONE 12V DC Power for detectors ett __ le ee ee ee ee eee D8 MAIN BOARD Eze l n Zone 8 EE GO END OF LINE RESISTORS 2K2 Zone 7 Ness control panels are supplied with 2200 Ohm 196 tolerance Metal T Film end of line resistors Colour code Red Red Black Brown Brown LISTEN PINS Lag Diagnostics Connect an 2k2 Zone 6 I zones ZONE WIRING m o M m M Zone A C2 Gb z 24 7 4 NORMALLY CLOSED 2K2 za RECEIVER rT N C DEVICES We LNG z ieir BOX TAMPER amp PROGRAM LINK 9 connecting as Sealed normal state 73 IY Zone 3 ZONES 1 8 lt optional Radio Tamper alarm state NORMALLY OPEN Zone QD ms D Interface Power up with link off to
6. Factory default ON Latched Keyswitch enabled MONITOR ARM CHIRPS BY RADIO KEY This option enables siren chirps when arming and disarming Monitor Mode with a Radio Key OFF No Monitor Arm chirps Factory default ON Monitor Arm chirps enabled RADIO AUX BUTTON ARMS MONITOR MODE This option enables the AUX button on a Ness RK4 Radio Key to arm Monitor Mode When this option is enabled options P122E 3E amp 4E will be disabled AUX button to Aux2 options See page 58 This option is independent of P69E 5E Monitor arming by radio key ON OFF buttons OFF No AUX button Monitor Arm Factory default ON AUX button Monitor Arm enabled KEYSWITCH DISARM ONLY Converts the use of keyswitch operation using P60E 2E and 3E to only DISARM either from Area or Monitor mode Keyswitch operation must first be enabled using options P60E 2E page 22 OFF Keyswitch arms and disarms Factory default ON Keyswitch disarms only KEYSWITCH ARM ONLY Converts the use of keyswitch operation using P60E 2E and 3E to only ARM either from Area or Monitor mode Keyswitch operation must first be enabled using options P60E 2 page 24 OFF Keyswitch arms and disarms Factory default ON Keyswitch arms only SMART BEEPS Smart Beeps are available in Brief Monitor or Brief Day mode to identify zones by keypad beeps When a Monitor zone or Day zone is triggered the zone number is slowly beeped out followed by 2 seconds o
7. S e 9 w 9 ale t Option No Description 1E 2E 3E 4E 5E 6E 7E 8E P87E MISC DIALLING OPTIONS ON ON SPLIT DIAL PRIMARY SECONDARY PHONE NUMBERS This option selects the order in which Telephone numbers 1 amp 2 are dialled PROGRAMMING SEQUENCE P87E 1E toggles the option ON and OFF OFF Alternate Dial Dial Telephone No 1 on the first attempt If no answer dial Telephone No 2 Continue alternating until successful ON Split Dial Dial Telephone No 1 for half of the call attempts If unsuccessful dial Telephone No 2 for the last half of call attempts CHECK FOR DIAL TONE The dialler can be programmed to check for a dial tone before dialling The dialler will still dial out if a dial tone is not detected but this means several seconds will have elapsed Allows use on PABXs with non standard dial tones PROGRAMMING SEQUENCE P87E 2E toggles the option ON and OFF OFF Dial without dial tone ON Dial only with dial tone NUMBER OF DIALLING ATTEMPTS Sets the number of dialling attempts when sending reports OFF sets a maximum 10 dial attempts before a 5 minute sleep and 10 more re tries if unsuccessful ON allows a maximum of 4 dial attempts before a 5 minute sleep and 4 more retries if unsuccessful If all attempts fail the dialler waits for the next trigger event The previously unsuccessful report will be included in the new message When sending Test
8. 1 Area2 open close 5 46 Siren Chirp Flash Options 46 Otlier Xteports c sto nct e eme i 47 Enable Test Calls eene 48 Mains Report 48 Listen in to dialler eeeeeeeennne 48 CONTENTS Swinger Shutdown see 49 Line Fault 49 Remote access options 50 51 Required Rings eene tne 52 No Memory Warning 20 52 SPECIAL FUNCTIONS Send test PA i o e eee et 52 Siren 16Sti a cn Redes 52 Panel fest 2 Lade dit 52 Display software 52 FACTORY DEFAULTS Clear Radio 53 Clear Memory eese 53 Clear Panel Options seen 53 Clear User Codes sse 53 OUTPUT EXPANDER Output Expander 54 55 AUX OUTPUTS Aux1 output options seee nwa 57 AUX2 output options seem m 58 Aux3 output options seem amana 59 Aux4 output options eee mm 59 Enable Disable hardwire 20 60 RADIO
9. AUX3 output pulses AUX4 ARM2 PULSE OUTPUT This option selects the AUX4 output to pulse on for 2 seconds whenever Arming or Disarming of Area2 The AUX4 output normally toggles when arming disarming Note also that when arming with the P60E 8E option selected that the pulse will occur at the end of Exit Time This option only applies when AUX4 output is enabled as Arm2 output P124E 1E on PROGRAMMING SEQUENCE P69E 2E toggles the option ON and OFF OFF AUX4 output toggles ON AUX4 output pulses QUIET MONITOR SIREN This option selects the Quiet Siren sound in Monitor Mode The Quiet Siren sound is a continuous beep beep beep sound rather than the normal siren sound PROGRAMMING SEQUENCE P69E toggles the option ON and OFF OFF Normal siren sound in Monitor Mode ON Quiet Siren sound in Monitor Mode Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL P69E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Keypad gives 3 beeps on Arming NOTES The keypad beeps on Arm Disarm when Arming Disarming by keypad keyswitch or by Radio Key PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Radio Keys cannot Arm Monitor Mode NOTES Radio Key Monitor Arming will work only if one or more zones have been programmed as Monitor Zones P51E When using a Radio Keypad to Monitor arm ensure that the ARM ONLY option is OFF for the USER CODE on the
10. contacts A momentary closed circuit across the resistor will toggle panels modes Open circuit the resistor to trigger Panic if required Panic on this input is disabled if P120E 1E is enabled If P120E 1E is enabled use a latching keyswitch When the resistor is sealed panel is disarmed If the resistor is unsealed either by open circuit or short circuit the panel will arm Area1 Area2 will be ignored KEYSWITCH WIRING A momentary or latching keyswitch can be wired as shown El Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL P60E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Tamper Reset Lockout enabled RELATED OPTIONS P44E Lockout zones PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Reset output on Duress alarm RELATED OPTIONS P75E 1E Enable reporting of Duress P60E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Auto Exclude enabled RELATED OPTIONS P62E 7E Siren burst on Auto Exclude P60E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Display is always ON NOTES The LCD keypad display and display backlighting will turn off but the keys backlighting will remain on The keypad flap can be closed to reduce stray light from the keys P60E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF AUX3 amp AUX4 outputs are instant RELATED OPTIONS P123E 1E AUX3 o
11. presented to a reader twice within 5 seconds PROGRAMMING SEQUENCE P301E 2E toggles the option ON and OFF OFF Do not Arm With Double Read ON Arm With Double Read ARM WITH SINGLE READ AND PUSHBUTTON When this option is enabled the panel will arm if a valid access card is presented to a reader once and zone 8 is unsealed momentarily within 5 seconds This option can be used to prevent accidental arming or disarming by access card PROGRAMMING SEQUENCE P301E toggles the option ON and OFF OFF Do not Arm With Single Read and Pushbutton ON Arm With Single Read and Pushbutton DISARM WITH ACCESS CARD When this option is enabled a valid access card will disarm the panel It will perform the same function as a keypad code E or a radio key off button PROGRAMMING SEQUENCE P301E toggles the option ON and OFF OFF Do not Disarm with access card ON Disarm with access card REQUEST TO EXIT REX INPUTS These options convert zones 5 6 and 7 into Request To Exit REX inputs for access control allowing for push button door exit Connect a N C or N O pushbutton to either open circuit or short circuit the zone resistor The REX zones can also be programmed as Long Response Zones P37E P38E to prevent accidental door opening the REX button must be pressed and held for 1sec or as programmed P301E 5E enables Zone 5 to trigger the AUX outputs assigned to Reader1 P301E 6E enables Zone 6 to trigger the AUX output
12. 2 Listen In disabled ON Method 2 Listen In enabled Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING P89E 4E SWINGER SHUTDOWN Limits the number of calls made by a zone alarm when Multiple Zone Alarms are PROGRAM MODE LEVEL enabled for that zone instaler Remote uy PG If enabled multiple reports are limited to three per zone FACTORY DEFAULT ON Swinger Shutdown enabled PROGRAMMING SEQUENCE NOTES P89E toggles the option ON and OFF This prevents unnecessary multiple OFF No Swinger Shutdown unlimited multiple reports alarms reported to the Central station ON Swinger Shutdown enabled maximum 3 reports per zone in cases for example where a door is swinging in the wind P89E 5E LINE FAULT MONITOR When this option is enabled the telephone line is regularly tested If the telephone line PROGRAM MODE LEVEL is not found the Line light will commence flashing Installer Remote by PC FACTORY DEFAULT PROGRAMMING SEQUENCE OFF No Line Fault Monitor P89E 5E toggles the option ON and OFF RELATED OPTIONS OFF No Line Fault Monitor P122E Line Fault to AUX2 ON Line Fault Monitor enabled P89E 7E INTERNAL TIMING When set ON the Test Report Timer uses the panel s onboard crystal oscillator instead ee RR E of the external mains power supply frequency luu remote by Po Use this option if the mains frequency is not stable over long periods Not necessary FACTORY DEFAULT in Au
13. Calls the time between dialling attempts increases to 60 minutes for the second round of dialling If a Test Call is unsuccessful after the first round of calls are made another call is made after 5 minutes If this call fails then subsequent calls are made every hour up to the maximum number of calls PROGRAMMING SEQUENCE P87E 4E toggles the option ON and OFF OFF Maximum 10 dialling attempts ON Maximum 4 dialling attempts Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING AREA open close report Mi AREA2 open close report Chirp siren on kiss off Flash strobe on kiss off Forced opening report Delay closing report Manual exclude report Auto exclude report A m o m Option No Description z o z P88bE OPEN CLOSE REPORTING OPTIONS ON P88E 1E AREA1 OPEN CLOSE REPORTS Enables or disables sending of AREA1 Open Close reports PROGRAM MODE LEVEL et The User ID of the code used is included in the report Installer Remote by PC Keyswitch arming is identified as User 57 Shortcut arming is identified as User 58 FACTORY DEFAULT OFF No AREA1 Open Close reports PROGRAMMING SEQUENCE P88E 1E toggles the option ON and OFF OFF No AREA1 Open Close reports ON AREA1 Open Close reports enabled P88E 2E AREA2 OPEN CLOSE REPORTS Enables or disables sending of AREA2 Open Close reports PROGRAM MODE LEVEL Installer Remote
14. Codes are automatically Keypad Codes e By factory default all user codes are Keypad Codes When a user code is selected as a Radio Code or Reader Code its Keypad Code if any is automatically deleted The same applies to Radio Codes and Reader Codes their codes are auto deleted when the code is changed to any other type User Code 1 is the Master Code and is always a keypad code and cannot be programmed to be a Radio Code or Reader Code TIP The Ness D8x D16x has 56 user codes which are programmed using a new set of options as per this table Experienced users can still use option numbers P11E P25E but only for programming user codes 1 15 RADIO PROGRAMMING See pages 62 63 USER CODES D8x and D16x version 5 and later have 56 User Codes which are used to operate the panel by a variety of methods Each User Code can be assigned to either a KEYPAD CODE or a RADIO KEY or an ACCESS CARD KEYPAD PIN CODES Up to 56 Keypad Codes can be used at up to wired keypads for control ling all panel functions including Arming Disarming Monitor Mode Panic memory recall and much more Keypad Codes can be 3 to 6 digits in length and can be individually programmed and deleted Keypad Codes can optionally be programmed to be Arm Only codes User Code 1 is also the Master Code which is used to enter Client Program mode All 56 User Codes are Keypad Codes by default User Codes can be p
15. Follow Me number is programmed the primary amp secondary numbers are ignored IF P86E 5E or 6E ARE ENABLED CONTACT ID AUDIBLE The telephone numbers programmed at P70E amp P71E will be used to send the mesage to the central station The message is also repeated in audible format to the telephone number if any programmed at POOE PROGRAMMING SEQUENCE POOE existing telephone number is displayed one digit at a time ENTER NEW TELEPHONE No E new telephone number is displayed one digit at a time Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING ZONES 1 8 D8 amp D16 ZONES 9 16 D16 Option No Description 123 4 5 6 7 849 10 11 12 13 14 15 16 P74E REPORT ZONE ALARMS ONJ ON ON ON ON ON ON ONJON ON ON ON ON ON ON ON P76E REPORT ZONE RESTORALS ONJ ON ON ON ON ON ON ONJON ON ON ON ON ON ON P78bE MULTIPLE ZONE ALARMS P79E ACCOUNT NUMBER 2 ZONES P74E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All zones report Alarms NOTES OE will turn all selections OFF MEMORY E will turn all selections ON P76E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All zones report Restorals NOTES OE will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P82E 1E Send Restoral immediately P82E 2E Send Restoral after siren time P82E Send Restoral on Disarm amp Seal P82E 4E
16. Mode Signal strength of all other Radio Devices is tested in INSTALLER PROGRAM Mode PRESS to test the signal strength of the selected transmitter ONLY Other devices will be ignored PRESS 4E to test the signal strength of ANY Ness transmitter including unpro grammed devices WEAK 1 8 BEST SIGNAL SIGNAL 1 beep 8 beeps PROGRAM ENABLE HARDWIRED ZONES This option allows hardwired zone inputs to be enabled or disabled Disabled zones are ignored and do not need to be terminated with end of line resistors This option has no effect on radio zones PROGRAMMING SEQUENCE P125E 1E 16E toggles the options ON and OFF Zone OFF Output Expander disabled for that zone Zone ON Output Expander enabled for that zone SIGNAL STRENGTH TEST The Signal Strength Test can be used to test the radio signal from any Ness radio device The strength of the radio signal received is displayed on the zone lights 1 8 and beeped by the keypad The higher the number displayed and beepeo the stronger the signal received TEST SEQUENCE Enter the option for the radio device to be tested For Radio Keys options 201 256 For Radio Devices options 101 116 Press Trigger the radio device One of zone lights 1 to 8 will turn ON to indicate the signal strength from the transmitter The Signal Strength display remains on until another command is entered To clear th
17. NERA mane 9 ue 9 6 6 Ness 8 D16x ALARM CONTROL PANEL INSTALLATION amp PROGRAMMING MANUAL Revision 55 A 15 00 Covering D8x D16x firmware versions up to v5 5 Australia s largest designer and manufacturer of high quality security products MADE AUSTRALIA Qo NESS SECURITY PRODUCTS Australian Communications Authority TELECOMMUNICATIONS COMPLIANCE Quality Endorsed Company 1509001 LIC No QEC2074 NSW Hoad Office only Security Products WWW Ress cCon atu Head Office Ness Security Products Pty Ltd ABN 28 069 984 372 4 167 Prospect Hwy Seven Hills NSW 2147 Australia Ph 61 2 8825 9222 Admin Fax 61 2 9838 8508 ness ness com au SYDNEY 4 167 Prospect Highway Seven Hills NSW 2147 Ph 02 8825 9222 Fax 02 9674 2520 sales ness com au MELBOURNE 24 Terracotta Drive Blackburn VIC 3130 Ph 03 9875 6400 Fax 03 9875 6422 nessmelb ness com au BRISBANE Unit 3 471 Lytton Road Morningside QLD 4170 Ph 07 3399 4910 Fax 07 3217 9711 nessbris ness com au PERTH Unit 1 567 Newcastle Street West Perth WA 6005 Ph 08 9328 2511 Fax 08 9227 7073 nessper ness com au ADELAIDE 13 Weaver Street Edwardstown SA 5039 Ph 08 8277 7255 Fax 08 8276 3028 adelaide ness com au D8x D16x INSTALLER MANUAL This revision November 2005 Document revision 5 5 covers D8x D16x firmware versions up to v5 5 Document Part Numbe
18. NES Normally Open N O wiring is possible only on Zones 1 to 8 This is done by splitting the 2 2 resistor into 2x 1K1 resistors joining them in series and then placing the contact across one of the 1K1 resistors Make a 1K1 resistor by wiring 2x 2K2 resistors in parallel Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL P68E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No zone resistors NOTES e The 3K3 zone resistor option is useful when installing the panel in a site pre wired with resistors If Zone 8 is converted to a keyswitch input then a 2K2 monitoring resistor is always used P68E 5E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Radio Key siren warning disabled P68E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No 24hr Fire siren sound NOTES The keypad key sequence for FIRE 3 E always outputs the FIRE siren sound P68E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Quiet Chirps disabled RELATED OPTIONS P64E 4E Radio Key Chirps P69E 5E Monitor Arm by Radio Key P120E 2E Monitor Arm chirps P120E 3E Radio Key AUX button arms Monitor Mode PROGRAMMING G z E Sales b T x z oz E 5 t og T Q N a JE 2 5 c lt
19. ON PROGRAM MODE LEVEL Range 1 24 seconds Installer Remote by PC RELATED OPTIONS PROGRAMMING SEQUENCE P318E P328E P338E P319E P329E or P339E existing Reader Output Time is displayed one digit at a time ENTER NEW VALUE E new value is displayed one digit at a time Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL WIRING A SINGLE READER P301E 1E is OFF Reader addresses not used Connect only 1 reader In this mode the panel is compatible with the 101 091 Ness IDTeck Fingerprint Reader or the 101 014 Ness Ultraprox Weigand Reader For longer cable runs use twisted 3 pair shielded cable with only one end of the shield connected to ground For cable runs exceeding 75m use the Ness Weigand data repeater Connect to READER header on the panel main board Violet not used VIOLET WIRE sets the reader number If P301E 1E is off 101 014 Ultraprox Weigand Reader Optional Reader Interface board this wire is not used Part No 106 012 REQUEST TO EXIT REX USING A KEYPAD CODE ACCESS CONTROL WIRING MULTIPLE READERS P301E 1E is ON Use Reader addresses When multiple readers are used the panel needs to identify the individual readers The 101 014 Ness Ultraprox Weigand Readers can be addressed as Reader 1 2 or 3 by connecting the Violet wire to an appropriate terminal Violet For READER 1 connect Violet
20. PROGRAMMING SEQUENCE P62E toggles the option ON and OFF OFF Siren burst on Auto Exclude disabled ON Siren burst on Auto Exclude enabled EXIT TIME X10 This option multiplies the normal exit time by a factor of 10 PROGRAMMING SEQUENCE P62E 8E toggles the option ON and OFF OFF Exit Time is the time set by P28E ON Exit Time is multiplied by 10 EXAMPLE If P28E 22 seconds then if P62E 8E is ON the exit time is 22 x 10 220 seconds Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL Ed PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E 2E ON 3E 4E OFF RELATED OPTIONS P64E 1E Brief Monitor alarm P63E 5E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 5E 6E ON 7E 8E OFF RELATED OPTIONS P64E 2E Brief Day alarm For ZONE TO OUTPUT MAPPING for armed amp 24hr states see options P54E P59E page 22 23 ia Lr 2 2 8l 11 1 1 8 e e lme el A aa eae S a Ww Lr E gt n 40 2 se 22 sls gt gt gt gt Option No Description 1E 2E 3E 4E 5E 6E 7E 8E P63E MONITOR amp DAY MODE MAPPING ONION ON MONITOR MODE OUTPUT MAPPIN
21. Send Restoral on Disarm always P78E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No zones report Multiple Alarms NOTES Only zones that have previously sent an Alarm will send a Restoral OE will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P89E 4E Swinger shutdown P79E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT none REPORT ZONE ALARMS This option selects which zone inputs will send Alarm reports to the Central Station PROGRAMMING SEQUENCE P74E Zone No E toggles the option ON and OFF Zone No E OFF Alarm reporting disabled for that zone Zone No E ON Alarm reporting enabled for that zone REPORT ZONE RESTORALS This option selects which zone inputs will send Restoral reports to the Central Station Only zones that have previously sent an Alarm will send a Restoral PROGRAMMING SEQUENCE P76E Zone No E toggles the option ON and OFF Zone No E OFF Restoral reporting disabled for that zone Zone No E ON Restoral reporting enabled for that zone REPORT MULTIPLE ZONE ALARMS Zones selected for Multiple Zone Alarms will report each time the zone alarms and without a restore being sent The number of reports is a maximum of 15 The number of alarms sent for each Multiple Zone Alarm can be reduced to 3 by using the swinger shutdown option P89E 4E Zones not selected report only once until reset by an opening or a valid code PROGRAM
22. Zone Split D16 only 3K3 Zone Resistors not used not used Radio Arming unsealed warning 24hr Zone Fire Siren sound not used Quiet chirps on radio Arm Disarm ARM1 output pulses ARM output pulses Quiet Monitor Siren 6 beeps on Arming Monitor arm by radio key ON OFF buttons Disable Mains Fail Alarm not used 6E Delayed Closing Reports not used Manual Exclude Reports 8bE Auto Exclude Reports Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL 73 DESCRIPTION ENABLE TEST CALLS DEFAULT Mains Report Delay 1 hour Listen In to Dialler Swinger shutdown Line Fault Monitor not used Use Internal Timing Enable Remote Access Enable First Call Mode Enable Remote Arming Enable Remote Disarming Enable Remote AUX control OPTION P123E 1E 6E 8E DESCRIPTION Area 1 armed output to AUX3 Page 3 of 3 DEFAULT Enable telephone remote control of AUXS Reader x output pulses AUX3 Area 2 armed output to AUX4 Enable Extension Sonalert Enable AUX4 as Fail To Communicate o p Enable telephone remote control of AUX4 Reader x output pulses AUX4 Enable hardwired zones Real Time Clock set MINUTES Enable Remote Status report Real Time Clock set HOURS Enable Remote Event Report
23. a Medical Alarm If P75E 2E must be enabled for the Medical alarm to be reported PROGRAMMING SEQUENCE P64E 8E toggles the option ON and OFF OFF No Keypad Medical Alarm ON Keypad Medical Alarm enabled Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING ZONES 1 8 D8 amp D16 ZONES 9 16 D16 Option No Description 123 4 5 6 7 8 9 10 11 12 13 14 15 16 P65E SUPERVISED ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all OFF No Supervision zones NOTES OE will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P66E 1E 4E Supervision Alerts P66E 5E Wired Zone Supervision P67E Zone Supervision Time P92E 4E D8 Report Supervision P75E 12E D16 Report Supervision P66E 1E 8E P67E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 24 hours or 24 minutes NOTES A setting of less than 3 hours for radio supervision is not recommended Supervision time must be 2 minutes or greater for correct operation The Supervision timer is reset on exit from Installer Program Mode and on Arm or Disarm RELATED OPTIONS P65E Supervised Zones P66E 1E 4E Supervision Alerts P66E 7E 8E Supervision Time Speed up SUPERVISED ZONES Any zone 1 8 or 1 16 can be a Supervised Zone In operation a Supervised Zone is subject to the Supervision Time P67E If the zone s has
24. be ON P86E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES Only one option in the range P86E 1E 6E is allowed to be ON The panel reports alarms to the Central Station using Contact ID dialler format The message format is fixed as shown in the Contact ID Codes Table THE MESSAGE TAKES THE FORM OF SSSS Account Number Q Event qualifier 1 New Event or Open 3 Restore or Close XYZ Alarm type GG Group or Area designation CCC Alarm number dd User ID 1 to 56 zz Zone ID 1 to 16 aa 01 Area 1 aa 02 Area 2 aa 01 Monitor area aa 00 24 Hr Area K Checksum 0 to Of hex CONTACT ID AUDIBLE DTMF FORMAT For simultaneous Central Station and Audible Monitoring The alarm message will be sent to the Central Station on the Primary telephone number and then in audible DTMF format to the Follow Me telephone number PROGRAMMING SEQUENCE P86E 5E turns the option ON ON Contact ID Audible DTMF format enabled CONTACT ID AUDIBLE PULSE FORMAT For simultaneous Central Station and Audible Monitoring The alarm message will be sent to the Central Station on the Primary telephone number and then in audible PULSE format to the Follow Me telephone number PROGRAMMING SEQUENCE P86E 6E turns the option ON ON Contact ID Audible PULSE format enabled CONTACT ID REPORTS TABLE REPORT NAME SSSS XYZ GG CCC SUFFIK Zone 1 Zone 16 Alarm ssss 18 001 016 Duress
25. digit at a time ENTER NEW TIME E new time is displayed one digit at a time EXAMPLE To program Entry Delay Time2 to be 600 seconds P27E 60E EXIT DELAY TIME The Exit Delay Time is the time given to secure and depart the premises after the Panel is Armed All zones except 24hr zones are inactive during the Exit Delay time The Exit Delay Time setting is from 1 to 99 seconds PROGRAMMING SEQUENCE P28E existing time is displayed one digit at a time ENTER NEW TIME E new time is displayed one digit at a time EXAMPLE To program Exit Delay to be 85 seconds P28E 85E SIREN RESET TIME The Siren Reset Time sets the duration of the Siren and Reset outputs The Siren Reset Time setting is from 1 to 99 minutes PROGRAMMING SEQUENCE P29E existing time is displayed one digit at a time ENTER NEW TIME E new time is displayed one digit at a time EXAMPLE To program Siren Time to be 4 minutes P29E 4E n Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL P30E P36E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Normal sensitivity P30E all zones ON NOTES Sensitivity can be individually programmed for each zone Zones are allocated to one sensitivity level at any one time Turning a zone ON in a sensitivity level turns the zone OFF in any other sensitivity level To revert zone sensitivity back to Normal turn on the required zone s at PSOE Sensitivity Level Extreme P31E is provi
26. enabled for that user code Extra Option 4E to DISARM To disarm and or reset Present a Card or Fob alarms Press User Cope WA once if P301E 4E is on Press the OFF button once to arm MONITOR MODE Press E The panel must initially be If the Monitor Suonrcur is enabled P62E disarmed See page 20 for more Press either the OFF Or press the AUX button information on arming button or the ON button once If P120E SE is on Monitor Mode twice within 4 seconds RK4 radio key only or press User Cope E P69E 5E must be on Radio Key Monitor Arm chirps can be enabled by option P120E 2E off by default PANIC alarm E Press QD Cx star keys together or press D User Cope E or press Cx E Press and hold the PANIC button for at least 4 sec If Panic is enabled P62E 4E KEYPAD DURESS Press 5 6 8 on 9 User Cope Keypad Duress allows Add one these digits in front of a user code when disarming the user to send a silent This sequence will disarm the panel and send a Duress report by duress report while dialler to the central station disarming if the system is being monitored by a Report Duress must be enabled P75E 1E central station EXCLUDE ZONES Press E EXCLUDE E can only If the ExcLube SHortcut is enabled P62E 2E b d when th li warmed then Zone No E Zone No Ente
27. enter 2K2 Zone 2 N 0 DEVICES cD DAD installer program mode 2 AUX 2K2 one Tom Aux outputs 14 QD iN DC Power for detectors etc SERIAL a NESS LED Keypad Connection for 100 192 NESS LCD Keypad direct up download BOX TAMPER Ch 100 667 using NessComms SWITCH figs software N C Contacts xr READER WHITE D HN 3 keypads E Connection for QD Up to 2 x Ness 12V Siren 100 172 2 up to 3 Ness OR 3 x 12V Screamer 100 238 100 004 m Weigand readers P HEARTBEAT LED G5 og 1 Up to 2 x Strobe Light NOI 300 Constantly flashes BATTERY LEADS le C Up to 3 x Horn Speaker 8 Ohm NOI 110 supplied 9 BLACK 17V AC Red amp Black d eee ai Pack 840 029 2 EARTH White lt O O L HEATSINK BATTERY CONNECTION For 12V 7Ah backup OPTIONAL ACCESSORIES D8 amp D16 NESS RADIO INTERFACE i i NESS RELAY BOARD OUTPUT EXPANDER i ACCESS CONTROL WEIGAND READERS Part No 100 200 i Part No 106 013 Part No 106 011 Un E To J5 Header i To READER i header Optional Reader Interface board Part No 106 012 TO RECEIVER HEADER Gf OL NNNM ifa NOCNC NOCNC NOCNC NOCNC AUX1 AUX2 AUX3 AUXA additional expander Connect up to one The Relay Board provides 4 relay outp
28. monitoring resistor is always used and Zone Splitting is not available on the Z8 input no Zone8 Zone16 Zone8 20 16 are still available as RADIO ZONES however See Keyswitch Operation page 24 N O contacts can be used only on zones 1 to 8 END OF LINE RESISTOR NOTES NESS supplies 196 tolerance metal film resistors for the end of line termination These are accurate value resistors and they stay accurate long term Avoid using carbon film or 5 tolerance resistors especially when zone splitting Problems may not become evident until some time after the installation due to resistor aging moisture or dust build up Ifa particular zone will not seal then check the resistance of BOTH the low zone and high zone cabling i e if zone 1 will not seal then also check zone 9 wiring The resistance checks should be done after removing the cabling from the D16 terminals and separating into their individual wires A2K2 monitored line should measure between 2100 Ohms minimum and 2400 Ohms maximum A 4K7 monitored line should measure between 4600 Ohms minimum and 4950 Ohms maximum INPUT TABLE ZONE 2 2 10 3 3 11 4 4 12 5 5 13 6 6 14 7 7 15 8 8 16 ZONE SPLIT IS ONLY AVAILABLE D16 CONTROL PANELS NOTE 1 The D16 panel has 16 physical zone inputs so Zone Split is usually not required although you may want to use Zone Split in cases where Retro fitting an
29. o SZ gs tu Zio 2 91 Option Description 1E 2E 3E 4E 5E 6E 7E 8E P68E MISC OPTIONS 3K3 ZONE RESISTORS Setting this option ON changes the Zones 1 8 monitoring resistor from 2K2 to 3K3 External Tamper input always uses a 2K2 resistor PROGRAMMING SEQUENCE P68E 2E toggles the option ON and OFF OFF 3K3 zone resistors disabled ON 3K3 zone resistors enabled RADIO KEY ARMING UNSEALED ZONE WARNING Setting this option ON allows a 2 second SIREN warning if there is an unsealed zone in an Area Armed by a Radio Key PROGRAMMING SEQUENCE P68E 5E toggles the option ON and OFF OFF Radio Key arming siren warning disabled ON Radio Key arming siren warning enabled 24HR ZONE FIRE SIREN SOUND This option changes the siren sound when a 24hr zone is triggered PROGRAMMING SEQUENCE P68E 6E toggles the option ON and OFF OFF Fire siren sound disabled ON Fire siren sound enabled QUIET CHIRPS ON ARM DISARM This quietens the siren chirps that are made whenever keyswitch or radio key Arming or Disarming is used Arm Disarm Chirps must be enabled at P64E 4E PROGRAMMING SEQUENCE P68E 8E toggles the option ON and OFF OFF Quiet Chirps disabled ON Quiet Chirps enabled Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF ARM1 output toggles NOTES This is useful
30. on Aux2 Factory default 7E ON DOTL alert turns on Aux2 READER OUTPUT TO AUX2 This option enables an access control reader to pulse Aux2 when a valid access card is presented Set the reader using P318E P328E or P338E 8E OFF No reader output to Aux2 Factory default 8E ON Reader output to Aux2 Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL 106 013 Relay Board AUX header AUXI AUX2 AUX3 AUX4 NOCNC NOCNC NOCNC NOCNC Separate Power Supply Diode is required to prevent spikes not supplied DOOR STRIKE Power To Open Recommended wiring of an electric door strike using a relay and separate power supply PROGRAM MODE LEVEL Installer Remote by PC NOTES This option makes Aux3 act like the Arm1 output on previous versions of D8 D16 RELATED OPTIONS P90E 5E Enable remote Aux control RELATED OPTIONS P318E P328E P338E P319E P329E P339E PROGRAM MODE LEVEL Installer Remote by PC NOTES This option makes Aux4 act like the Arm2 output on previous versions of D8 D16 NOTES The extension beeper can either be a standard 12V sonalert or wire directly to the Ness Quantum Sonic as shown Keypad beeps will be heard at low volume from the Quantum Sonic s onboard siren Normal siren sound is unaffected 12V Sonalert EO Connects to PROGRAMMING AUX3 OUTPUT OPTIONS 5 25 Sets the behaviour of
31. or Area modes P117E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Output Exclude PROGRAMMING DAY ZONE FOLLOWER This option allows Day zones to appear on the Zone Outputs In Day mode the Zone Output will follow the state of any active Day zone This occurs independently of the Program Zone selections P118E Output Expander Zone Follower and P119E Output Expander Zone Latch PROGRAMMING SEQUENCE P117E toggles the option ON and OFF OFF No Day Zone Follower ON Day Zone Follower enabled OUTPUT EXCLUDE This allows zones selected for Manual Exclusion not Auto Exclusion to also Exclude the Expander Zone outputs With this option ON and if a zone has been manually excluded then it will not signal an alarm on the Expander PROGRAMMING SEQUENCE P117E 4E toggles the option ON and OFF OFF No Output Exclude ON Output Exclude enabled ZONES 1 8 D8 amp D16 ZONES 9 16 D16 Option No Description 123 4 5 6 7 849 10 11 12 13 14 15 16 P118E OUTPUT EXPANDER ZONES P119E OUTPUT EXPANDER ALARM ZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All OFF No Output Expander zones NOTES Selecting a zone in both P118 amp P119 options effectively gives pulsed outputs whenever that zone alarms PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Output Expander zone latch OUTPUT EXP
32. panel Otherwise further MONITOR E keypresses on the Radio keypad could AREA arm the panel RELATED OPTIONS P51E Program Monitor zones P63E Monitor Mode output mapping P64E 1E Brief Monitor alarm P64E 3E Monitor zones have Entry Delay2 P64E 4E Radio Key Chirps P69E 3E Quiet Monitor siren P69E 5E Monitor Arm by Radio Key P120E 2E Monitor arm chirps by radio key P120E 3E Radio Key AUX button arms monitor mode P120E 6E Smart Beeps for Monitor and Day zones P69E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Mains Fail alarm normal NOTES This does not affect Dialler mains fail reporting or saving to the History memory or operation of the Mains Fail output on the Output Expander PROGRAMMING 6 BEEPS ON ARMING Normally the keypad s onboard SONALERT gives 3 beeps when the panel is armed Turning this option ON will give 6 keypad beeps when Arming PROGRAMMING SEQUENCE P69E toggles the option ON and OFF OFF Keypad gives 3 beeps on Arming ON Keypad gives 6 beeps on Arming MONITOR ARMING BY RADIO KEY ON OFF BUTTONS Setting this option on allows MONITOR Mode arming by Radio Key ON or OFF buttons Note This is independent of Monitor arming by AUX button if using the RK4 radio key PROGRAMMING SEQUENCE P69E 5E toggles the option ON and OFF OFF Radio Key Monitor Mode Arming disabled ON Radio Key Monitor Mode Arming enabled OPERATION Panel version 4 Press the Radio Key OF
33. set to dial in PULSE Decadic or DTMF dialling or auto selct depending on dial tone Factory default is DTMF dialling This option should not be changed for use in Australia New Zealand or Europe PROGRAMMING SEQUENCE P85E 1E 3E turns the option ON 1E ON Auto Select Dialling PULSE or DTMF 2E ON Pulse Dialling always 3E ON DTMF Dialling always m Ness D8x D16x Control PANEL INSTALLATION MANUAL P86E 1 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Off dialler enabled NOTES This option is useful for temporary disabling of the dialler without affecting other dialler options Only one option in the range P86E 1E 6E is allowed to be ON P86E 2 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Contact ID format enabled NOTES Only one option in the range P86E 1E 6E is allowed to be ON P86E 3E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES Only one option in the range P86E 1E 6E is allowed to be ON P86E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES Only one option in the range P86E 1E 6E is allowed to be ON This is the best option to select for Audible Monitoring PROGRAMMING Disable Dialler Contact ID Format Audible DTMF format Audible PULSE format Contact ID Audible DTMF Contact ID Audible DTMF N m m A m m o m Option No Description 7
34. the Aux3 output E 3 3 S Only one option can be selected E c 35 lt Iy 25 Oo 0 8 oz o lt SE 3 lt 5 8 Option Description 1E 2E 3E 4E 5E 6E 7E 8E P123E AUX3 OUTPUT OPTIONS ON PROGRAMMING SEQUENCE P123E 1E 8E Turns an option on Only one option can be on AREA1 ARMED OUTPUT TO AUX3 When this option is enabled Aux3 will turn on and off when Area1 is armed and disarmed 1E OFF Areal armed output does not turn on Aux3 1E ON Area armed output turns on Aux3 Factory default ENABLE TELEPHONE REMOTE CONTROL OF AUX3 Enables Aux3 output to be controlled by telephone remote control PSOE 5E must also be enabled After establishing telephone control of the panel use telephone key 5 to toggle the output on and off 6E OFF Aux3 cannot be controlled by telephone Factory default 6E ON Aux3 can be controlled by telephone READER OUTPUT TO AUX3 This option enables an access control reader to pulse Aux3 when a valid access card is presented Set the reader using P318E P328E or P338E 8E OFF No reader output to Aux3 Factory default 8E ON Reader output to Aux3 x m AUX4 OUTPUT OPTIONS x 25 c Sets the behaviour of the Aux4 output E 2x 8 2 Only one option can be selected a sles 95 Oo 2 99 orlec Gc e E re S co 5 o Ta Option No Description 1E 2E 4E 5E 6E 7E 8b P124E
35. to STROBE output Keypad Panic to Sonalert Keypad Panic to SIREN output Options marked u can be programmed in User Program Mode All options can be programmed in Installer Program Mode Ness D8x D16x Control PANEL INSTALLATION MANUAL Page 2 of 3 OPTION DESCRIPTION DEFAULT OPTION DESCRIPTION DEFAULT Shortcut Memory display TELEPHONE NO 1 Primary Shortcut Zone Exclude Telephone No 2 Secondary Shortcut Monitor Mode ACCOUNT NO 1 0000 Shortcut Keypad Panic Account No 2 0000 S hortcut 1 Arming REPORT ZONE ALARMS All zones Shortcut Area 2 Arming P75E 1 Report DURESS alarms Brief warning on Auto Exclude D8 amp D16 2 Report MEDICAL alarms Exit Time x10 Report keypad amp Keyswitch PANIC Monitor alarms to RESET output Report FIRE alarms Monitor alarms to STROBE 5E Report PANEL TAMPER alarms Monitor alarms to SONALERT 6E Report EXTERNAL TAMPER alarms Monitor alarms to SIREN 7 Report KEYPAD TAMPER alarms Day Mode to RESET output 8E Report EXIT FROM INSTALLER mode Day Mode to STROBE pie bose JE Report RADIO TAMPER Day Mode to keypad SONALERT bie Pree iE Report RADIO PANIC by User ID Day Mode to SIREN pie bos tig Report RADIO LOW BATTERY by device Brief Monitor Alarm bie prse1ze Report ZONE SUPERVISION FAIL Brief Day Alarm 0108 225 8 Report PANEL LOW BATTERY Monitor zones Entry Delay2 Report MAINS FAIL Radio Key SIREN CHIRPS Report Zone Restorals 50Hz Mains F
36. use of the arm key on the keypad in the case of radio codes the radio key OFF button will toggle the armed state of the area assigned to the radio key If the User code is assigned to both AREA 1 and AREA 2 If AREA 1 is already armed then entering the code will disarm AREA 1 but arm AREA 2 If the intention is to either ARM or DISARM both areas using this code then ARM code must be used first to arm both areas Once both are armed they can be disarmed it in Monitor mode then the action is to exit Monitor mode Codes selected for Code Only Arming and not assigned to any areas are automatically REX codes See page 69 5E RADIO CODE Enables selected user codes as Radio Codes for operation by Ness Radio Key or Radio Keypad Page 63 how to program Radio Codes 6E READER CODE 1 Enables user codes as Access Control codes assigned to Reader 1 Page 65 Access Cards 7E READER CODE 2 Enables user codes as Access Control codes assigned to Reader 2 Page 65 Access Cards 8E READER CODE 3 Enables user codes as Access Control codes assigned to Reader 3 Page 65 Access Cards A user code can be assigned to any one two or all three access control readers Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 20 seconds NOTES Programmable from 1 99 seconds P27E PROGRAM MODE LEVEL User Insta
37. walk tested without waiting for the 4 minute re transmit timer to expire If the TEST link is left on the PIR will automatically revert to normal mode after 30 minutes The Ness R12 and R15 Radio PIRs have a TEST link which disables the re transmit TEST mode can be re started by briefly removing then replacing the battery E Ness D8x D16x PANEL INSTALLATION MANUAL USER CODE OPTIONS OPTIONS TABLE USER CODE 1 Master MODE Exclude Light is on 5E RADIO CODE OPTION NO A 100 664 100 067 Ness RK3 Ness RK4 Q Radio Key Radio Key RADIO CODES NESS RADIO 100 001 Ness RKP Radio Keypad Each of the 56 User Codes except for the Master Code can be programmed to be Radio Codes This allows up to 55 Ness Radio Keys to be used for Arming and Disarming of the panel The Ness RKP Radio Keypad can also be used with the D8 D16 see the RKP installer manual The optional 100 200 Ness Radio Interface is required for radio operation PROGRAMMING RADIO KEYS Use the Extra Options programming mode to enable selected user codes as Radio Codes When a user code is enabled as a Radio Code its Keypad Code if any is automatically deleted PROGRAMMING SEQUENCE In Installer Program Mode enter
38. 1E TELEPHONE NUMBER 2 SECONDARY P80E TELEPHONE NUMBER TEST CALLS P81E TELEPHONE NUMBER 4 CALLBACK FOR UPLOAD POOE FOLLOW ME TELEPHONE NUMBER For audible dialling P72E ACCOUNT NUMBER 1 0000 P73E ACCOUNT NUMBER 2 0000 TELEPHONE NUMBERS 1 amp 2 The panel can dial up to 2 phone numbers when an event is to be transmitted to a central monitoring station or other location Telephone numbers may be up to 30 digits in length PROGRAMMING SEQUENCE P70E existing telephone number is displayed one digit at a time ENTER NEW TELEPHONE E new telephone number is displayed one digit at a time EXAMPLE To program Telephone No 1 to be 03 1234 1234 P 70 E 0312341234 E SPECIAL FUNCTIONS FOR ALL TELEPHONE NUMBERS TO CLEAR A TELEPHONE NUMBER To clear a telephone number enter the MEMORY key in place of the telephone number Example to clear a Telephone Number 1 press P7OE MEMORY E SPECIAL CHARACTERS Applies to all telephone Numbers Pauses star or hash VF digits can be included in the dialling sequence by using the keys in the table below SPECIAL CHARACTER KEY ENTRY DISPLAYED ON LCD DISPLAY PAUSE 1 6sec ARM Key 12 Star MONITOR Key 10 Hash EXCLUDE Key 11 ACCOUNT NUMBER 1 amp 2 Account numbers for identifying the panel to the Central Station Area 1 Open Close reports will report on Account No 1 and Area 2 Open Close reports will report on Account No 2 Zone Alarms can be
39. 29E P339E PROGRAMMING AUX1 OUTPUT OPTIONS x 2 x es 2 Sets the behaviour of the Aux1 output ES a 2 m 2 Only one option can be selected 2 51025 E 5 18 9T T EIS S 5g amp uj 9 S9 sg 0 lt m o Eegen 5 5 5 59180 85 8 N us A lt Option Description 1E 2E 4E 5E 6E 7E 8E P121E AUX1 OUTPUT OPTIONS ON PROGRAMMING SEQUENCE P121E 1E 8E Turns an option on Only one option can be on ZONE ALARMS TO AUX1 With this option ON zones selected in P58E will turn on Aux1 when they go into alarm The Aux1 output turns off when the panel is disarmed reset 1E OFF Zone Alarms do not turn on 1 1E ON Zone Alarms turn on Aux1 Factory default ZONE SUPERVISION ALARMS TO AUX1 Setting this option turns the AUX1 output ON when a SUPERVISED RADIO alarm is triggered The Aux1 output turns off when the panel is disarmed reset 2E OFF Zone Supervision Alarms do not turn on Aux1 Factory default 2E ON Zone Supervision Alarms turn on Aux1 RADIO KEY PANIC TOGGLE When this option is on Radio Key s Panic button will TOGGLE the Aux1 output The Aux1 output will operate independently of the panel s armed status ie disarming does not turn Aux1 off OFF Radio Key Panic does not Toggle Aux1 Factory default ON Radio Key Panic Toggles Aux RADIO KEY PAN
40. 7 D16 as supplied All inputs must be sealed with an EOL resistor unless disabled by option P125E For wiring details of Keypads Keyswitches Panic Buttons and Warning devices see the wiring diagrams in the wiring section of this manual TAMP Tamper Input The TAMP input must also be sealed with a 2K2 end of line resistor This input is always a 24hr input AC INPUT TERMINALS These terminals are for the connection of the Ness plugpack The Ness D8 D16 requires an AC transformer rating of 1 4 Amps 17 V AC minimum Ness Part No POW215 BATTERY These terminals are for the connection of a sealed lead acid rechargeable 12Volt battery Charge current is limited to 350mA The charge voltage is factory preset at 13 8V and does not need changing Note A 12 Volt sealed lead acid rechargeable battery must be connected for correct panel operation Observe correct polarity when connecting the battery Ness Part Number BAT210 12V 7Ah battery EARTH For maximum protection against damage caused by lightning strikes connect a good earth to this terminal Alternatively use the Earth lead from the plug pack PROG TAMP Program Link amp Internal Tamper Input The PROG TAMP link appears on the two pin J1 header The PROG TAMP link has two purposes 1 To enter Installer Program Mode on initial power up Power up with the PROG link OFF The PROG link or Box Tamper lead must be ON in operating mode 2 Box Tamper When used wi
41. 9E Zone toggles the options ON and OFF unwanted alarms from zones in harsh environments such as sheds and garages Zone No OFF The zone is not a Double Trigger zone Zone No ON The zone is a Double Trigger zone OE will turn all selections OFF MEMORY E will turn all selections ON AA NSTANT ZONES PROGRAM MODE LEVEL Instant Zones operate only in the Armed state When Armed at the expiry of exit time Installer Remote by PC Instant Zones will activate assigned outputs immediately when triggered FACTORY DEFAULT P40E Zone turns the options ON D8 3E 8E ON Zones 3 8 are Instant Zone No ON The zone is an Instant Zone D16 3E 16E ON Zones 3 16 are To deselect the option select a different zone type in the DELAY GROUP Instant NOTES When a zone is selected for this type it is automatically deselected from any other zone type in the DELAY GROUP a ENTRY DELAY1 ZONES PROGRAM MODE LEVEL Entry Delay1 zones operate only in the Armed state When Armed at the expiry of exit Installer Remote by PC time these zones will activate the Entry Delay Timer1 P26E when they are triggered If the panel is not disarmed before the expiry of the Entry Delay Timer1 the alarm FACTORY DEFAULT outputs will be activated 1E ON Zone 1 has Entry Delay1 P41E Zone NoJE turns the options ON NOTES Zone No ON The zone is an Entry Delay1 zone The keypad sonalert will beep during To deselect the option selec
42. ACTORY DEFAULT no zones selected NOTES OE will turn all selections OFF MEMORY E will turn all selections ON NO MEMORY WARNING ZONES Select zones that do not flash the Memory indicator on the keypad s The alarm still goes into memory and can be seen when reviewing PROGRAMMING SEQUENCE P94E 1E 16E toggles the option ON and OFF Zone No E OFF Memory Warning operates normally for that zone Zone ON Memory Warning is disabled for that zone SPECIAL FUNCTIONS SEND DIALLER TEST REPORT Send a Dialler Test Report to the telephone numer programmed at P70E This test operates only in User program mode 66666666 eight 6 s Triggers dialler and sends test report to Central Station SIREN TEST Turn the Siren Reset and Strobe Outputs On Pressing P E will stop the Siren Test and also exits Program Mode This test operates in User and Installer program mode P77777777E eight 7 s Triggers Siren Reset Strobe PANEL RESET This function resets the microprocessor The effect is the same as powering down and powering up again Panel Reset operates in User and Installer program mode P88888888E eight 8 s Panel Reset PANEL SOFTWARE VERSION This function displays the panel software version when in program mode Displayed in decimal format by the zone LEDs Example version 5 4 is displayed by flashing 5 followed by 4 This test operates in User and Installer program mode P999999999E eight 9 s Displays
43. ADIO EMERG BUTTON RSM RADIO SMOKE DETECTOR ARM DISARM 100 001 15 User IDs 100 665 100 664 ON OFF buttons 100 067 ON OFF buttons 100 691 100 663 100 662 100 527 100 283 100 203 ALARM yes yes yes RESTORAL yes PANIC star buttons PANIC button PANIC button PANIC button AUX yes yes LOW BATT yes yes yes yes yes yes yes yes TAMPER yes SUPERVISION yes yes yes yes PANIC button NESS RADIO INTERFACE The Ness Radio Interface 100 200 is the optional radio receiver required to enable all radio functions Connection to the control panel is via a 4 wire loom and plug supplied with the Ness Radio Interface If the Ness Radio Interface is correctly installed the keypad will flash the RADIO light ON when any radio signal is detected from both programmed and non programmed radio devices NESS RADIO INTERFACE Part No 100 200 NESS D8 OR D16 CONTROL PANEL RECEIVER J2 NOTES The Ness Radio Interface is normally installed inside the control panel box n cases where radio reception needs to be improved the optional 100 200 Radio Interface can be installed up to 50 metres away from the control panel Use 14 0 20 SHIELDED cable or equivalent The shield can either be connected to the EARTH connection or left unconnected Leave the shield unconnected at the receiver end e f the Radio Interface must be installed inside a metal
44. AMMING SEQUENCE P66E 5E toggles the option ON and OFF OFF Radio Zone Supervision enabled ON Wired Zone Supervision enabled SUPERVISION TIME SPEEDUP X6 Setting this option speeds up the Supervision Time by 6 For instance if P67E is set to 1 hour 60 minutes then this option will reduce it to 10 minutes i e 60 divided by 6 PROGRAMMING SEQUENCE P66E 7E toggles the option ON and OFF OFF Supervision Time normal as set by P67E ON Supervision Time speedup x6 SUPERVISION TIME SPEEDUP X10 Setting this option speeds up the Supervision Time by 10 For instance if P67E is set to 1 hour 60 minutes then this option will reduce it to 6 minutes i e 60 divided by 10 PROGRAMMING SEQUENCE P66E 8E toggles the option ON and OFF OFF Supervision Time normal as set by P67E ON Supervision Time speedup x10 NOTE If both P66E 7E and 8E are both ON then the Supervision time is sped up by 60 For instance if P67E is set to 1 hour 60 minutes then this option will reduce it to 1 minute i e 60 divided by 60 SUPERVISION TIME page 31 Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING P68E 1E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No zone split NOTES Zone Split is required when zones 9 16 are used as hardwire zones Zone Split does not have to be enabled to use zones 9 16 as RADIO zones If Zone 8 is converted to a Keyswitch Input then a 2K2
45. ANDER ZONES This selects the zones that will be output whenever the zone is unsealed When the zone reseals the output automatically goes off Additionally if a zone is also selected in P119 to zone latch then an output will only occur whenever a zone is in alarm and is also unsealed In this case when the zone reseals the output automatically goes off again A further zone unseal will turn the zone Expander output On again PROGRAMMING SEQUENCE P118E 1E 16E foggles the options ON and OFF Zone No E OFF Output Expander disabled for that zone Zone No E ON Output Expander enabled for that zone OUTPUT EXPANDER ALARM ZONES This selects the zones that will be output whenever the zone is latched into alarm The output goes off only when the alarm system is reset Additionally if a zone is also selected in P118 to zone follow then an output will only occur whenever a zone is in alarm and is also unsealed See P118 above PROGRAMMING SEQUENCE P119E 1E 16E toggles the option ON and OFF Zone No E OFF Output Expander zone alarm disabled for that zone Zone No E ON Output Expander zone alarm enabled for that zone Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL Ea PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC RELATED OPTIONS P60E 2E 3E Keyswitch options NOTE This option enables Radio Key Monitor Arming chirps regardless of the state of P64E 4E Radio Key siren itis Q n NOT
46. AUX4 OUTPUT OPTIONS ON AREA2 ARMED OUTPUT TO AUX4 When this option is enabled Aux4 will turn on and off when Area2 is armed and disarmed 1E OFF Area2 armed output does not turn on Aux4 1E ON Area2 armed output turns on Aux4 Factory default ENABLE EXTENSION SONALERT Enables the Aux4 output to duplicate all keypad beeps including keypress beeps This is useful in cases where for example entry beeps or other keypad beeps need to be heard in more than one location on the premises Adding an additional keypad would achieve the same effect 2E OFF Extension sonalert disabled Factory default 2E ON Extension sonalert enabled gt D8 D16 AN Reset output Reset O Reset Quantum Sonic Siren input AcL v 0000 wmDuDikComoPen imums Wen Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING NOTES P87E 4E should be OFF to enable 10 dialling attempts This will allow the dialler to communicate via the alternative pathway on the 5th dialling attempt Assuming AUXA has already triggered the backup communications device THIS OPTION IS AVAILABLE IN D8X D16X V5 5 AND LATER RELATED OPTIONS P90E 5E Enable remote Aux control P124E 8 RELATED OPTIONS P318E P328E P338E P319E P329E P339E FAIL TO COMMUNICATE OUTPUT When this option is enabled AUX4 will turn on at the start of the fourth dialout attem
47. DE E enters Extra Options mode enables the Arm Only option then EXCLUDE E toggles back to normal user code program mode When the code is viewed in program mode the ARMED icon is briefly displayed before the digits of the code To disable the Arm Only feature for a keypad code simply enter the option for that code press EXCLUDE E to view Extra Options then press 3 E without re entering a new code This retains the existing code and toggles off the Arm Only feature The Arm Only feature also applies to Radio Keys and Access Cards Arm Only codes can also arm the panel directly from Monitor Mode Normally user codes can arm the panel only if it is fully disarmed Arm Only codes can also arm Monitor Mode as normal Radio Keys programmed as an Arm Only can toggle the armed disarmed state of the panel using the OFF button on the radio key 14 Ness D8x D16x Control PANEL INSTALLATION MANUAL USER CODE OPTIONS TABLE USER OPTION NO EXCLUDE E toggles EXTRA OPTIONS MODE The Exclude light indicates this mode is on off Installer Program mode only 7E AREA AREA ARM CODE RADIO Reader Reader Reader KEYPAD 1 2 ONLY ONLY CODE Code 1 Code 2 Code 3 CODE CODE ARM 1 Master
48. E 8E P86E REPORTING FORMATS 2 DISABLE DIALLER This option disables the dialler even if telephone numbers and other dialler options are programmed Up download or remote telephone access remain enabled PROGRAMMING SEQUENCE P86E 1E turns the option ON ON Dialler disabled CONTACT ID FORMAT This option enables the reporting of alarms to a Central station via telephone numbers 1 amp 2 using Contact ID format PROGRAMMING SEQUENCE P86E 2E turns the option ON ON Contact ID format enabled AUDIBLE DTMF FORMAT For Audible Monitoring to any telephone or mobile phone The last digit of the Account number and the zone alarm are sent in Audible DTMF format The message is repeated for 45 seconds or until kissed off by the receiving telephone PROGRAMMING SEQUENCE P86E turns the option ON ON Audible DTMF format enabled AUDIBLE PULSE FORMAT For Audible Monitoring to any telephone or mobile phone The last digit of the Account number and the zone alarm are sent in Audible PULSE format The message is repeated for 45 seconds or until kissed off by the receiving telephone PROGRAMMING SEQUENCE P86E 4E turns the option ON ON Audible PULSE format enabled Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING P86E 5E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES Only one option in the range P86E 1E 6E is allowed to
49. E This option enables Radio Key Monitor Arming chirps regardless of the state of P64E 4E Radio Key siren chirps RELATED OPTIONS P69E 5E Radio key Monitor arm by ON OFF buttons RELATED OPTIONS P120E 1E Latched Keyswitch P60E 2E 3E Keyswitch options RELATED OPTIONS P120E 1E Latched Keyswitch P60E 2E 3E Keyswitch options z m o The zone causing the event is saved and can be identified by viewing MEMORY Only one of the same consecutive zone warnings is saved although the MEMORY display will flash each time unless disabled by P94E option Smart Beeps work in addition to any other outputs mapped to Monitor and Day alarms as programmed by options P63E 1E 8E Smart Beeps work in conjunction with any other Monitor and Day mode outputs as set by options 6 1E 8E 2 15 gt 5 5 v lt lt n 2 8 5 2 5 ESE E I e s e o 2 Secs E Slo eese Jf Option No Description 1E 2E 3E 4E 5E 6E 7E 8E P120E OTHER OPTIONS PROGRAMMING SEQUENCE 120 1 Turns options on or off LATCHED KEYSWITCH This option enables the use of a latched 2 position on off keyswitch Keyswitch operation must first be enabled using options P60E 2 page 24 NOTE ENABLING LATCHED KEYSWITCH DISABLES ALL OTHER METHODS OF ARMING AND DISARMING KEYPAD RADIO KEY CARD OFF No Latched Keyswitch
50. E 4E toggles the option ON and OFF 1E ON Send Restoral immediately 2E ON Send Restoral after siren time 3E ON Send Restoral on Disarm amp seal 4E ON Send Restoral on Disarm always Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 84 168hrs 7 days NOTES Enter a value from 1 to 99 RELATED OPTIONS P89E 1E Enable Test Calls P84E Time Before Next Test Call P84E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 6 12hrs NOTES 1 Enter a value from 1 to 99 2 If Test Calls are to start immediately then the value is set to 0 3 The Time Before Next Test Call is constantly updated When viewed the current value will be displayed not the initially entered value RELATED OPTIONS P89E 1E Enable Test Calls P83E Test Call interval PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 3E ON DTMF Dialling always NOTES Only one option is allowed to be ON THE DECADIC OR PULSE DIALLING ON THIS DEVICE IS UNSUITABLE FOR USE ON THE TELECOM NETWORK IN NEW ZEALAND Option No Description Default Note P83E TEST CALL INTERVAL 84 x2 168hrs P84E TIME BEFORE FIRST TEST CALL 6 x2 12hrs TEST CALL INTERVAL Test calls to the Central Station can be sent at intervals between 2 and 198 hours in 2 hour increments Programmable from 2 to 198 Hours Enter a value be
51. E 7E DOTL Alerts to Aux2 RELATED OPTIONS P117E 1E Enable Output Expander DOOR OPEN TOO LONG DOTL ZONES This selects the zones that will generate a DOTL alert if the zone is unsealed for longer than the time set by P304E The types of alerts are set by P121E 7E P122E 7E and P305E PROGRAMMING SEQUENCE 1E 16E toggles the options ON and OFF OFF DOTL is disabled for that zone ON DOTL is enabled for that zone Option No Description Default Note P304E DOTL TIME 20 01 99 seconds DOTL TIME Sets the delay time in seconds before a DOTL zone generates a DOTL alert Enter a value between 01 and 99 PROGRAMMING SEQUENCE P304E existing DOTL time is displayed one digit at a time ENTER NEW VALUE E new value is displayed one digit at a time 5 9 5 gt ane 2g 3x 8 amp x Su S iiu 30 Sales 28 5EBS 53 ao af Option No Description 1E 2E 4E 5E 6E 7E 8b DOTL ALERTS PROGRAMMING SEQUENCE P305E 1E 8E toggles the options ON and OFF DOTL OUTPUT LATCHES With this option on DOTL alerts will either follow the sealed unsealed state of DOTL zones or latch the Aux output s which have been programmed for DOTL alerts 1E OFF DOTL Outputs follow the state of DOTL zones set by P303E Factory default 1E ON DOTL Outputs latch on until reset by disarming the panel DOTL ALERTS TO OUTPUT EXPANDER With this option
52. E LEVEL Installer Remote by PC FACTORY DEFAULT all ON All zones trigger Strobe output NOTES OE will turn all selections OFF MEMORY E will turn all selections ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All ON All zones sound the Keypad Sonalert NOTES OE will turn all selections OFF MEMORY E will turn all selections ON ZONE TO OUTPUT MAPPING When zone alarms it can turn on any or all of the following 6 outputs Sonalert Strobe Siren Reset AUX1 AUX2 The programming is selected with options 54 P59E Simply set the zone number to the output to select it The zone LED will indicate if the zone is selected The Tamper Input and the Keypad Panic can be programmed to turn on the Reset Strobe Sonalert and Siren by using option P61E MAPPING ZONES TO OUTPUTS ZONES 1 8 D8 amp D16 ZONES 9 16 D16 Option No Description 123 4 5 6 7 8 9 10 11 12 13 14 15 16 P54E RESET Zones ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON P55E STROBE Zones ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON P56E SONALERT Zones ONJ ON ON ON ON ON ON ONJ ON ON ON ON ON ON ON ON P57E SIREN Zones ONJ ON ON ON ON ON ON ONJON ON ON ON ON ON ON ON P58E AUX1 Zones P59E AUX2 Zones RESET OUTPUT ZONES Selects the zones to trigger the Reset output PROGRAMMING SEQUENCE P54E Zone No E toggles the options ON and OFF Zone No OFF T
53. Enable Callback Mode Real Time Clock set DAY Required rings to answer Report Misc Alarms 9 14 D8 only Report Misc Restorals 9 14 D8 only No Memory Warning zones CLEAR RADIO DEVICES CLEAR MEMORY Real Time Clock set MONTH Real Time Clock set YEAR CLEAR PANEL OPTIONS restore Factory Defaults P99E P101E P116E P117E 1E 2E 3E CLEAR User codes Radio Keys Access Cards Program the INSTALLER CODE PROGRAM RADIO DEVICES 1 8 or 1 16 Enable Output Expander 000000 none Alternate Expander Format Day Zone Follower Real Time Clock set DAY OF WEEK ACCESS CONTROL OPTIONS P301E 1E 2E 3E 4E 5E 6E 7E 8E DEFAULT ALL ACCESS CONTROL OPTIONS Use reader addresses Arm with double read Arm with single read and pushbutton Disarm with access card REX Input 1 Zone 5 input REX Input 2 Zone 6 input REX Input 3 Zone 7 input Strobe Flash on Arm Disarm by Reader DOTL zones Output Exclude Output Expander zones DOTL time Output Expander alarm zones Latched keyswitch input Monitor Arm Chirps Radio Key AUX arms Monitor mode Keyswitch DISARM ONLY Keyswitch ARM ONLY Smart Beeps Brief Monitor amp Day modes Zone alarms to AUX1 P58E selects zones Zone Supervision alarms to AUX1 Radio key Panic TOGGLE Radio key Panic PULSE not used Enable telephone remote control of AU
54. F button twice within 4 seconds Panel version 4 5 and later Press the Radio Key OFF button twice within 4 seconds Press the Radio Key ON button twice within 5 seconds See page 20 for Monitor operation DISABLE MAINS FAIL ALARM When set ON a Mains Fail alarm is 1 Not displayed on the keypad 2 Does not give warning beeps 3 Is not saved to MEMORY and the MEMORY display does not flash PROGRAMMING SEQUENCE P69E GE toggles the option ON and OFF OFF Mains Fail alarm operates normally ON Mains Fail alarm is disabled Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL 37 PROGRAMMING 7 P71E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No telephone numbers NOTES If telephone number 2 is disabled all calls are made on telephone number 1 and the setting of P87E 1E has no effect If telephone number 3 is disabled all test calls are made on telephone number 182 Any keypress will stop the telephone number display sequence RELATED OPTIONS P87E 1E Alternate Primary Secondary telephone numbers P86E 1E Disable dialler still allows remote up download if programmed P72E P73E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT P72E Account No 1 0000 P73E Account No 2 0000 RELATED OPTIONS P79E Account No 2 zones Also see page 39 Hex Client Codes Option No Description Default P70E TELEPHONE NUMBER 1 PRIMARY P7
55. FF The zone will not trigger the Siren output Zone No ON The zone will trigger the Siren output AUX1 OUTPUT ZONES Selects the zones to trigger the AUX1 output on the main board This option selects which zones trigger AUX1 Use P121E to enable the ouput Once turned on by a zone alarm the output will remain on until the panel is reset disarmed PROGRAMMING SEQUENCE P58E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger the AUX1 output Zone No ON The zone will trigger the AUX1 output AUX2 OUTPUT ZONES Selects the zones to trigger the AUX2 output on the main board This option selects which zones trigger AUX2 Use P122E to enable the ouput Once turned on by a zone alarm the output will remain on until the panel is reset disarmed PROGRAMMING SEQUENCE P59E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger the AUX2 output Zone No ON The zone will trigger the AUX2 output Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL E3 PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Entry Beeps ON NOTES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No keyswitch enabled P60E SE 4E off P120E 1E off NOTES The keyswitch always Arms Area only The keyswitch always Disarms both Area1 and Area2 RELATED OPTIONS P120E 1E Latched Keyswitch P120E 4E Keyswitch Disarms only P120E 5E Keyswitch Ar
56. G This option selects which outputs are triggered by alarms in Monitor Mode PROGRAMMING SEQUENCE 6 1E 4E toggles the options ON and OFF 1E ON Monitor Mode to Reset output 2E ON Monitor Mode to Strobe output 3E ON Monitor Mode to Keypad Sonalert output 4E ON Monitor Mode to Siren output DAY MODE OUTPUT MAPPING This option selects which outputs are triggered by alarms in Day Mode PROGRAMMING SEQUENCE P63E 5E 8E toggles the options ON and OFF 5E ON Day Mode to Reset output 6E ON Day Mode to Strobe output If Brief Day Alarm is enabled P64E 2E then this option sends day alarms to the AUX2 output 7E ON Day Mode to Keypad Sonalert output 8E ON Day Mode to Siren output Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Brief Monitor Alarm disabled RELATED OPTIONS P51E Set Monitor zones P63E 1E 4E Monitor Mode output mapping PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Brief Day Alarm disabled RELATED OPTIONS P53E Assign Day zones 6 5E 8E Day Mode output mapping PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Monitor zones all have Entry Delay 2 RELATED OPTIONS P27E Entry Delay Time 2 P51E Assign Monitor zones P63E 1E 4E Monitor Mode output mapping P64E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No siren chirps
57. IC PULSE When this option is on Radio Key s Panic button will PULSE the Aux1 output on for 2 sec 4E OFF Radio Key Panic does not Pulse Aux1 Factory default 4E ON Radio Key Panic Pulses Aux1 ENABLE TELEPHONE REMOTE CONTROL OF AUX1 Enables Aux1 output be controlled by telephone remote control PSOE 5E must also be enabled After establishing telephone control of the panel use telephone key 3 to toggle the output on and off 6E OFF Aux cannot be controlled by telephone Factory default 6E ON Aux1 can be controlled by telephone DOOR OPEN TOO LONG DOTL ALERTS TO AUX1 This option enables DOTL zones P303E to turn on Aux1 when the DOTL Time P304E expires TE OFF alert does not turn on Aux1 Factory default TE ON DOTL alert turns on 1 READER OUTPUT TO AUX1 This option enables an access control reader to pulse Aux1 when a valid access card is presented Set the reader using P318E P328E or P338E 8E OFF No reader output to Aux1 Factory default 8E ON Reader output to Aux Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING 106 013 Relay Board ov Saw Connects to AUXI AUX2 va AUX header JJ NOCNC NOCNC NOCNC NOC NC Separate Power Supply Diode is required to prevent spikes not supplied DOOR STRIKE Power To Open Recommended wiring of an electric door strike using a r
58. LAY 2 Monitor zones can either have the delay types set by options 40 or they can all be assigned to have Entry Delay 2 This allows all Monitor zones to be programmed with the same entry delay time PROGRAMMING SEQUENCE P64E toggles the option ON and OFF OFF Monitor zones behave as programmed by P40E P43E ON Monitor zones all have Entry Delay 2 ARM DISARM CHIRPS If this option is selected the Siren output will Chirp when the panel is armed and disarmed with the Keyswitch input prox cards or Radio Keys This option applies to siren chirps the strobe output always flashes when arming disarming by the above methods Monitor arming chirps are enabled separately by option P120E 2E The siren output will make 1 Chirp on Arming and 3 Chirps on Disarming PROGRAMMING SEQUENCE P64E toggles the option ON and OFF OFF No Arm Disarm siren chirps ON Siren amp Strobe outputs will chirp on arm disarm Ness D8x D16x Control PANEL INSTALLATION MANUAL 29 PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON 50Hz mains frequency NOTES P64E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Double key Keypad Panic enabled NOTES The Ness LCD keypad has two buttons labelled 0 RELATED OPTIONS P62E 4E Shortcut Keypad Panic P64E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Keypad Fire Alarm RELATED OPTIONS
59. MING SEQUENCE P78E Zone No E toggles the option ON and OFF Zone No E OFF Multiple Zone Alarms disabled for that zone Zone No E ON Multiple Zone Alarms enabled for that zone ACCOUNT NO 2 ZONES Zones selected to be Account No 2 zones will report their Alarms Restorals and Excludes on Client code 2 PROGRAMMING SEQUENCE P79E Zone No E toggles the option ON and OFF Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL P75E P92E REPORT MISCELLANEOUS ALARMS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT see table NOTES OE will turn all selections OFF MEMORY E will turn all selections ON P77E P93E REPORT MISCELLANEOUS RESTORALS PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT see table P82E 1E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 4E ON Always send Restoral on Disarm RELATED OPTIONS P76E Report zone restorals PROGRAMMING ALARM RESTORAL D8 01 6 DEFAULT PERAULT ALARM RESTORAL ALARM RESTORAL Duress ON P75E 1E P77E 1E P75E 1E P77E 1E Medical ON P75bE 2E P77E 2E P75E 2E P77E 2E KP Panic amp KS Panic ON ON P75E P77E SE P75E SE P77E Fire ON P75E 4E P77E 4E P75E 4E P77E 4E Panel tamper ON ON wage 7 External tamper ON ON P75E 6E P77E 6E P75E 6E P77E 6E Keypad Tamper ON ON P75E 7E P77E 7E P75E 7E P77E 7E Exit Insta
60. OF 5 sg 2 a 3 E mE P29E SIREN RESET TIME Minutes lt ce 62285 me a G PEO g Z gt amp PIR Reed Do D D D ZONES DEVICE TYPE witch etc DESCRIPTION Entrance bedroom ete X F amp F F D P D D D k D8 amp D16 ileliej o o on 5 o w 2 E Extra Options Assigned Extra Options Assigned Extra Options Assigned OPTION No E g Radio Code USER OPTION No E g Radio Code OPTION No E g Radio Code Arm Only etc CODE Arm Only etc Arm Only etc 1 Master Code Ness Security Products
61. OPTIONS Signal strength test 60 Ness Radio 61 Radio Devices 61 RADIO DEVICE PROGRAMMING 62 RADIO KEY 63 Real Time Clock 64 ACCESS CONTROL OPTIONS PROGRAMMING ACCESS CARDS 65 Access Control 65 68 Weigand Reader wiring diagram 69 REMOTE OPERATION Monitoring operation 70 Remote operation by telephone 71 PROGRAMMING OPTIONS SUMMARY 72 74 Operation summary essen 75 Installation Record 76 L FEATURES 8 or 16 alarm zones Supports up to 3 remote LCD or LED keypads 56 user codes can be programmed to operate by keypad PIN radio key or access card Optional Ness Radio Interface for fully integrated wireless security Programmable 2 Area partitioning can split the panel into two independent areas plus a common area Monitor Mode allows partial arming eg permieter security overnight Day Mode feature allows daytime monitoring of fire doors coolrooms etc Temporary Day Zone feature allows
62. P68E 6E Fire Siren sound P75E 4E Report Fire Alarms P64E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Keypad Medical Alarm RELATED OPTIONS P75E 2E Report Medical Alarms 50Hz MAINS FREQUENCY Selects either 50Hz or 60Hz mains power frequency operation Leave the factory default for use in Australia and New Zealand Users in North America should select 60Hz mains frequency Required for the accurate timing of dialler test reports if programmed It has no effect on local or other dialler operations PROGRAMMING SEQUENCE P64E 5E toggles the option ON and OFF OFF 60Hz mains frequency ON 50Hz mains frequency DOUBLE KEY KEYPAD PANIC This option allows the Keypad Panic alarm to be triggered by pressing both 2 Panic buttons together NOTE lt gt User Code always triggers Keypad Panic PROGRAMMING SEQUENCE P64E GE toggles the option ON and OFF OFF No double key Keypad Panic ON Double key Keypad Panic enabled KEYPAD FIRE ALARM This option enables the Keypad Fire Alarm Pressing 3 and then E triggers the siren using the Fire Alarm siren sound If P75E 4E is enabled the fire alarm is reported by dialler to the central station PROGRAMMING SEQUENCE P64E 7E toggles the option ON and OFF OFF No Keypad Fire Alarm ON Keypad Fire Alarm enabled KEYPAD MEDICAL ALARM This option enables the Keypad Medical Alarm Pressing 2 and then E activates the dialler and reports
63. P94E P99E P117E P125E 1 135 P281E P287E P301E P303E P304E P305E P311 P319E P321E P329E P331 P339E This includes all options except User Codes Radio Codes amp Radio Devices PROGRAMMING SEQUENCE P97E Restores Factory Defaults CLEAR USER CODES This option clears all User Codes this means all Keypad Codes Radio Keys and Access cards and restores User Code 1 to the factory setting of 123 P201E P256E are defaulted User Codes 1 56 PROGRAMMING SEQUENCE P98E Clears User Codes PROGRAM THE INSTALLER CODE Programs the installer code This code can be 3 to 6 digits long Factory default installer code is 000000 PROGRAMMING SEQUENCE P99E Enter new code E Enter new code again E Unlike User Codes the installer code is not displayed when programming For a complete list of factory default values see the Programming Options Summary on pages 72 74 Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING Output Expander 106 011 gt a o M o o a e x 117 1 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Output Expander NOTES Up to 2 Output Expander boards can be used per D8 or D16 panel P117E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Alternate Format NOTES The 2nd Expander plugs into the 6 way header on the 1st Expander This 6 way header on the Expander can
64. RELATED OPTIONS P68E 8E Quiet Chirps P69E 5E Monitor Arm by Radio Key P120E 2E Monitor Arm chirps P120E SE Radio Key AUX button arms Monitor Mode PROGRAMMING a gt G a gt 2 5 ui amp E E 8 esie eria es E Sie a Slelelelel amp leleals x o eS E3554 ES o3 ec A N a 3 zm a a oc LO a gt Pa Option No Description 1E 2E 3E 4E 5E 6E 7E 8E P64E MISC OPTIONS ON ON ON BRIEF MONITOR MODE ALARM Alarms in Monitor Mode can either activate the programmed outputs for Siren Time duration P29E or they can activate the outputs for 2 seconds only NOTE If Brief Monitor alarm is enabled then Monitor alarms will not be reported by dialler PROGRAMMING SEQUENCE P64E 1E toggles the option ON and OFF OFF Monitor Mode outputs have normal time as set by P29E ON Monitor Mode outputs are ON for 2 seconds only BRIEF DAY ALARM Alarms in Day Mode will activate the programmed outputs while the zone is unsealed or they can activate the outputs for 2 seconds only This option also enables the TEMPORARY DAY ZONE feature See page 20 PROGRAMMING SEQUENCE P64E 2E toggles the option ON and OFF OFF Brief Day Alarm disabled Day alarm outputs are ON while the zone is unsealed ON Brief Day Alarm Enabled Day alarm outputs are ON for 2 seconds only MONITOR ZONES ENTRY DE
65. RY DEFAULT all OFF No Day zones RELATED OPTIONS P63E 5E 8E Day zone output mapping P64E 2E Brief Day Mode alarm P120E 6E Smart Beeps for Monitor and Day zones TYPICAL USES FOR DAY ZONES Instant alert when a delivery door is opened doorway alert for a shop PROGRAMMING ASSIGNING USER CODES TO AREAS Options P201E P256E are now used for assigning user codes to areas Experienced users can still use options PA7E P50E for this function but only up to user code 15 MONITOR ZONES Monitor zones allow you to Arm selected zones while others are ignored Typically used for perimeter zones such as windows and doors while you are at home For example upstairs zones are Disarmed while downstairs zones are Armed in Monitor mode PROGRAMMING SEQUENCE P51E Zone No E toggles the options ON and OFF P51E Zone No E OFF The zone is not a Monitor zone P51E Zone No E ON The zone is a Monitor zone NOTE Zones selected to Report Zone Alarms P74E will by default report alarms in Monitor Mode if the dialler is enabled The Brief Monitor Alarm option 64 1E when enabled prevents monitor alarms from reporting See page 20 for Monitor operation 24hr ZONES 24hr Zones operate at all times regardless of the mode of panel operation i e Armed Disarmed or Monitor When alarmed these zones will activate assigned outputs immediately To reset those alarms a valid user code must be entered Selecting a zone as 24hr wil
66. SUPERVISED SIGNALS have also been successfully recognised the TAMPER light will turn ON EXAMPLE To program a Radio PIR on zone 1 P101E 1E Trigger the Radio PIR or simply connect the battery PROGRAMMING SEQUENCE WITH RESTORALS Suitable for 100 662 Radio Reed Switch Alarm the reed switch ie move the magnet away from the switch Leave the reed switch in the alarm condition and wait until radio transmission has stopped Select a zone using P101E P116E The ARMED light will be ON if a Radio Device is already programmed to the zone Press OE to delete Press 1E The READY light will turn ON to indicate that the zone is ready to accept the Radio Device Restore the reed switch place the magnet next to the switch A If the Radio Device is accepted the READY light will turn off the ARMED light will turn on and 3 beeps will sound B The MEMORY light will turn on to indicate that this device sends Restorals C If the READY light stays on and a warning beep sounds the Radio Device is already assigned to another zone and must be cleared from that zone first D If SUPERVISED SIGNALS have also been successfully recognised the TAMPER light will turn ON EXAMPLE To program a Radio Reed Switch with Restorals on zone 2 Alarm the reed switch P102E 1E Restore the reed switch DELETING A RADIO DEVICE Use P101E to P116E to select the zone Press OE to clear the device 3 beeps will sound timer allowing the detector to be
67. Time Normal Zone Sensitivity all zones Master P31E 36E Vibration Sensitivity High Low none P37E Long Response Zones 1 second none P38E Long Response Zones 3 seconds Double Trigger zones Instant zones none zones 3 ENTRY DELAY 1 zones Zone 1 HANDOVER zones Zone 2 Entry Delay 2 zones none Lockout zones RESET output AREA 1 zones All zones All zones P51E AREA 2 zones MONITOR MODE zones none none See page 2 0 for information on Area operation Monitor mode amp Temporary Day Zones P52E 24hr zones none P53E Day Mode zones none P54E RESET output zones All zones P55E STROBE zones All zones P56E Keypad Sonalert zones All zones P57E SIREN zones All zones P58E Aux1 zones none P59E EB Aux2 zones Entry Beeps none Keyswitch Monitor Disarm Keyswitch Arm Disarm Tamper Siren lockout Duress to RESET output Auto Exclude zones Auto keypad display off Delayed Aux3 Aux4 outputs Tamper to RESET output Tamper to STROBE output Tamper to Keypad Sonalert Tamper to SIREN output Keypad Panic to RESET output Keypad Panic
68. USER CODE ASSIGNMENT A User Code assigned to an Area can arm and disarm only that Area User Codes as signed to both Areas will operate both Areas simultaneously OPERATION Arming and disarming is carried out as normal from a single keypad or separate keypads installed in both areas or by Radio Key Area operation only applies to zones when they are in the armed state This means that Day zones and 24hr zones are independent of area operations TEMPORARY DAY ZONES The Temporary Day Zone feature allows easy and flexible Day Zone selection and operation While remaining in normal operating mode the user can add and remove Temporary Day Zones and enable disable day zone operation using simple key strokes TO ENABLE TEMPORARY DAY ZONES To enable Temporary Day Zone selection and operation the Brief Day Alarm feature installer option 64 2E must be ON If P64E 2E is OFF the Temporary Day Zone feature will be unavailable but Permanent Day Zones will still operate and will sound the programmed output while the zone is unsealed P64E 2E is OFF by default USER COMMANDS In normal Operating Mode P E Selection Mode Enter P followed by E when in operating mode to enter Temporary Day Zone selection mode Zone No E Zone Selection To select or deselect zones to be Temporary Day AREA PARTITIONING amp MONITOR MODE The panel can be armed in MONITOR mode if Area2 is already armed on these conditi
69. Use the E button preferably PROGRAMMING SEQUENCE P60E 7E toggles the option ON and OFF OFF Display is always on ON Display will blank after 4 minutes DELAYED AUX3 amp AUX4 OUTPUTS The AUX3 and AUXA outputs can be programmed to turn on when Areas 1 and 2 are armed These outputs can be programmed to turn on instantly or at the end of Exit Time This option only applies when AUX3 and AUX4 outputs are enabled as Arm1 and Arm2 outputs P123E 1E on and P124E 1E on PROGRAMMING SEQUENCE P60E 8E toggles the option ON and OFF OFF AUX3 amp AUX4 outputs turn on instantly Default ON AUX3 amp AUX4 outputs turn on at the end of exit time Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL E3 PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E 4E ON Tamper alarm triggers all outputs NOTES A Tamper Alarm can be caused by the TAMP input or by removing the the J1 PROG TAMP link on the main board P61E 5E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 5E 8E ON Panic alarm triggers all outputs NOTES A Keypad Panic Alarm can be caused by the PANIC keys on the keypad E or together depending on Option P64E6E Tamper to keypad SONALERT KP Panic to RESET output m KP Panic to keypad SONALERT m Tamper to RESET output m Tamper to STROBE output m Tamper to SIREN output m Option No Description KP Panic to STROBE outp
70. X1 Door Open Too Long DOTL alarm to AUX1 Reader x output pulses AUX1 Zone alarms to AUX2 P59E selects zones DOTL output LATCHES DOTL outputs to Output Expander not used not used DOTL zone flashes on keypad AUX OUTPUTS Ultraprox Reader1 to AUX1 Ultraprox Reader1 to AUX2 Ultraprox Reader1 to AUX3 Ultraprox Reader1 to AUX4 Ultraprox Reader1 output TIME Ultraprox Reader2 to AUX1 Ultraprox Reader2 to AUX2 Ultraprox Reader2 to AUX3 Ultraprox Reader2 to AUX4 Zone Supervision alarms to AUX2 Radio key Aux Button TOGGLE Radio key Aux Button PULSE Telephone Line fault to AUX2 Ultraprox Reader2 output TIME Ultraprox Reader3 to AUX1 Ultraprox Reader3 to AUX2 Ultraprox Reader3 to AUX3 Ultraprox Reader3 to AUX4 Enable phone remote control of AUX2 Door Open Too Long DOTL alarm to AUX2 Reader x output pulses AUX2 Ultraprox Reader3 output TIME 74 Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL OPERATION SUMMARY OPERATION by KEYPAD by RADIO KEY by ACCESS CARD or FOB to ARM Press E Present a Card or Fob The panel must initially be If the SHorrcur is enabled P62E 5E twice if P301E 2E is disarmed on or press User Cope Or present a Card or Fob once press button if P301E 3E is on or press User Cope If Cope AnuiNG has been
71. Zones Monitor 20 Zone To Output 22 23 Various Options 24 25 Tamper Keypad Panic Output Mapping 26 System Operation 27 Monitor mode output 28 Day mode output 28 Miscellaneous Options 29 30 Zone Supervision 31 33 Zone Split D16 34 MISC 35 37 DIALLER OPTIONS TELEPHONE NUMBERS 38 39 Account 38 Report zone 40 Report zone 40 Report multiple zone 40 Account No 2 zones ssessse ee 40 Report Miscellaneous alarms 41 Report Miscellaneous Restorals 41 Test Call options sme 42 Dialler format 43 44 CONTACT ID REPORTING CODES 44 Dialling options 45
72. are displayed Zone No E EXAMPLE To program zones 2 and 3 to be Medium sensitivity P34E 2E the keypad display will show zone lights 2 amp 3 on ZONES 1 8 D8 amp D16 ZONES 9 16 D16 Option No Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 P30E NORMAL ON ON ON ON ON ON ON ON ON ON ON ON P31E Vibration EXTREME P32E Vibration HIGHEST P33E Vibration HIGH P34E Vibration MEDIUM P35E Vibration LOWER VIBRATION OPTIONS P36E Vibration LOWEST 1 second ZONES P38E 3 second ZONES Extreme sensitivity P31E should not be used It is provided as a guide only Ness NESSENSOR Vibration Sensor Part No VIB100 In addition to zone sensitivity adjustment the overall sensitivity of the Nesssensor can be adjusted by rotating the body of the Nesssensor within its bracket 9 9 6 N C Tamper Lasso PN Sa The Nessensor bracket Gee must always be mounted H 2x 3mm holes Y horizontally and the arrow tus EGE mustpoint up for any required setting RED Vibration I DE BLUE J contacts 20mm L S YELLOW LONG RESPONSE ZONES Long Response Zones are normal alarm zones with a long reaction time Individual zones can be programmed to have either a 1 second response P37E or 3 second response P38E This is useful where zones 5 6 or 7 have be
73. as a Smoke Detector reset output with an optional external relay RELATED OPTIONS P60E 8E Delay ARM1 ARM2 outputs P123E 1E AUX3 output when Areat armed PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF ARM2 output toggles NOTES This is useful as a Smoke Detector reset output with an optional external relay RELATED OPTIONS P60E 8E Delay ARM1 ARM2 outputs P124E 1E AUX4 output when Area2 armed PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Normal siren sound in Monitor Mode NOTES This does not affect the RESET output o gt 5 5 E a 5 T e le amp 2 o s 2 Pas o 6 6 0 o c S amp 15 1 2 fr fey SS gt N alale rala sS tc oc 3 Q oO o Gio cra Option No Description 1E 2E 3E 4E 5E 6E 7E 8E 69 MISC OPTIONS 2 AUX3 ARM1 PULSE OUTPUT This option selects the AUX3 output to pulse on for 2 seconds whenever arming or disarming of Area1 The AUX3 output normally toggles when arming disarming Note also that when Arming with the P60E 8E option selected that the pulse will occur at the end of Exit Time This option only applies when AUX3 output is enabled as Arm1 output P123E 1E on PROGRAMMING SEQUENCE P69E 1E toggles the option ON and OFF OFF AUX3 output toggles ON
74. assigned to report on either Account Number as set by Option P79E All miscellaneous events eg Tampers Mains Fail will report on Account No 1 PROGRAMMING SEQUENCE P72E or P73E existing account number is displayed one digit at a time ENTER NEW ACCOUNT No E new account number is displayed one digit at a time EXAMPLE To program Account No 1 to be 1239 P72E1239E Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL HEX CLIENT CODE NOTES Note 1 If using the Ness LED keypad for programming the Hex digits will not be displayed but are still programmed Note 2 Hex digit A is not allowed Note 3 Entering Hex digits by keypad applies to D16 V4 6 and later Previous 016 versions by using NessComms Up download software V4 62 or later P80E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No telephone numbers RELATED OPTIONS P89E 1E Enable test calls P83E Test call interval P84E Test call start delay PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No telephone numbers RELATED OPTIONS P90E 8E Enable Callback PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT No telephone numbers NOTES If the Follow Me telephone number is disabled all audible format calls are made on telephone numbers 1 amp 2 RELATED OPTIONS P86E Audible DTMF format P86E 4E Audible Pulse format P86E 5E Contact ID Audible DTMF P86E 6E Contact ID Audible Pulse
75. attery or open the RADIO link Remember to enable all the devices when programming is completed 100 527 100 662 Ness Universal Ness Radio 100 691 100 663 Transmitter Reed Switch Ness R12 Radio PIR Ness R15 Radio PIR RADIO DEVICE PROGRAMMING Each of the zones of the D8 or D16 can be a radio zone Once programmed zones can accept both radio devices and normal zone inputs simultaneously The optional 100 200 Ness Radio Interface is required for radio devices to operate A radio device is any type of Ness transmitter including Radio PIR Radio Reed Switches Radio Smoke Detector PROGRAMMING RADIO DEVICES Up to 8 or 16 radio devices can be assigned to the D8 and D16 one per zone PROGRAMMING SEQUENCE NO RESTORALS Suitable for 100 663 R15 Radio PIR 100 691 R12 Radio PIR 100 665 Radio Pendant 100 203 Radio Smoke Detector Select a zone using P101E P116E options P109E P116E apply to 016 only The ARMED light will be ON if a Radio Device is already programmed to the zone Press OE to delete Press 1E The READY light will turn ON to indicate that the zone is ready to accept the Radio Device Trigger the Radio Device A If the Radio Device is accepted the READY light will turn off the ARMED light will turn on and 3 beeps will sound B If the READY light stays on and a warning beep sounds the Radio Device is already assigned to another zone and must be cleared from that zone first C If
76. by PC PROGRAMMING SEQUENCE FACTORY DEFAULT P88E 2E toggles the option ON and OFF OFF No AREA2 Open Close OFF No AREA2 Open Close reports ON AREA2 Open Close reports enabled P88E 3E SIREN CHIRP ON KISS OFF Selects a 2 Second Siren burst on a successful Closing report This is used to give PROGRAM MODE LEVEL audible indication that the dialler has successfully sent the Arming report Installer Remote by PC FACTORY DEFAULT PROGRAMMING SEQUENCE OFF No Siren Chirp on kiss off P88E toggles the option ON and OFF OFF No Siren Chirp on kiss off Ce ON Siren Chirp on kiss off enabled P88E 4E Flash Strobe on kiss off P88E STROBE FLASH ON KISS OFF Selects a 2 Second Strobe on a successful Closing report This is used to give visual PROGRAM MODE LEVEL indication that the dialler has successfully sent the Arming report Installer Remote by PC FACTORY DEFAULT PROGRAMMING SEQUENCE OFF No Strobe Flash on kiss off P88E toggles the option ON and OFF OFF No Strobe Flash on kiss off RELATED OF LIONS ON Strobe Flash on kiss off enabled P88E 3E Siren Chirp on kiss off 46 Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL P88E 5E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Forced opening Reports enabled NOTES This option is used to indicate to the Central Station that an alarm has been reset by a valid user Usually used in cases where Open Close reports are n
77. ccount Number P72E is known The panel answers on the 2nd incoming call WITH CALLBACK The panel will answer the 2nd call verify the caller hang up and then make the Callback using Telephone Number 4 PROGRAMMING SEQUENCE P90E 8E toggles the option ON and OFF OFF No Callback ON Callback Mode enabled 000 wxDmMD amp CeePe hwmw 0 4T Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1 NOTES The Australian double ring tone is counted as one ring RELATED OPTIONS P90E 1E to 8E Remote Access options Option No Description Default Note P91E REQUIRED RINGS TO ANSWER 1 1 to 24 rings REQUIRED RINGS Sets the number of rings before an incoming call is answered This is used for remote access of the panel either by NessComms software or user operation by telephone Remote Access can work in First Call or Second Call modes see option P9OE 2E Programmable from 1 to 24 rings Enter a value between 1 and 24 PROGRAMMING SEQUENCE P91E existing Required Rings value is displayed one digit at a time ENTER NEW VALUE E new Required Rings value is displayed one digit at a time ZONES 1 8 D8 amp D16 ZONES 9 16 D16 Option No Description 123 4 5 6 7 8 9 10 11 12 13 14 15 16 P94E NO MEMORY WARNING ZONES PROGRAM MODE LEVEL Installer Remote by PC F
78. creamer Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL KEYPAD D8 amp D16 KEYPADS The Ness LED or LCD keypad provides important visual and audible indication of the system status and is the main interface for controlling the many powerful features of the system DISPLAY TEST LCD KEYPAD ONLY To display all the keypad icons press and hold the button for at least 2 seconds All the icons will be on whilst the E button is held down Display Test can be activated at any time either in operating mode or any program mode NUMBER OF KEYPADS Up to 3 LED and or LCD keypads can be connected to the D8 panel Up to 3 LCD keypads can be connected to the D16 panel CABLE LENGTH The maximum allowable cable length is 100m total cable length to all keypads 91 KEYPAD INSTALLATION Unclip the top half of the keypad housing by pushing the top clips down with a small screwdriver and pulling the housing forward Screw the base of the keypad housing to the wall using the 4 mounting holes provided Bring the 4 connecting wires to the termi nal block on the PCB on the rear of the keypad housing Connect the wires to the screw terminals as per the wiring diagram shown in this manual Clip the top half onto the base by first en gaging the bottom clips and swinging the top closed Push hard to ensure the clips engage Attach the Zone list label on the inside of the lid n Nes
79. ction for zo vO WIYAS C BATTERY CONNECTION For 12V 7Ah backup direct up download using NessComms SWITCH software N C Contacts READER WHITE m Connection for up to 3 Ness co Weigand readers ww HEARTBEAT LED Constantly flashes BATTERY LEADS supplied I BLACK RED O HEATSINK battery BAT210 SIREN WIRING D8 amp D16 NESS D8 D16 CONTROL PANEL TAMP rov 12V 7 7 8 T T NIN T N O wo lt 1 Ld SSS OSS eeeeeeceee LoJ g N O TAMPER SWITCH TELEPHONE LEAD Supplied Connect to Mode3 socket Lead shown is for Australia only N O TAMPER SWITCH 761 002 Colour BLACK NESS D16 CONNECTION DIAGRAM ALTERNATIVE TAMPER SWITCH WIRING For N C Tamper Switches Supplied with Ness siren covers N C TAMPER SWITCH 511920 Colour WHITE n ee DKS cil 7 XO x 2V DC Power for detectors etc WIRING ZONE INPUTS ZONES 9 16 2K2 Zone 8 Physical zones 9 16 are wired the same as zones 2K2 Zone7 1 8 using a 2 2 resistor on each zone Oe If Zone Split is enabled these zone inputs are disabled ge REIN 2K2 Zone 6 OIE non L END OF LINE RESISTORS a 2K2
80. d then call the number again within 50 seconds 3 The panel will answer the second call immediately sound a beep for 2 seconds then after a pause it will sound a lower frequency tone The panel is now ready to receive telephone commands 4 Press the 0 button on the telephone This tells the panel that telephone commands will follow The panel will respond with either 3 beeps if all OK One long beep means try again 5 Now enter a valid User Code that is normally used for Arming or Disarming the panel followed by the button The panel will respond with 3 beeps if it recognises the code or 1 long beep to signal the code was invalid and to try again 6 Enter the required command See Summary Of Telephone Commands 7 Press to finish This tells the panel to hang up Also hang up your telephone Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL ul USER CODE OPTIONS TABLE EXCLUDE E toggles Extra Options mode Installer Program mode only PAGE 14 15 Pge 63 Page 65 2E 4E 5E 6E 7E OPTION POOE DESCRIPTION Follow Me Telephone Number ENTRY DELAY Time 1 Page 1 of 3 DEFAULT none AREA AREA ARM CODE RADIO Reader Reader Reader USER OPTION kEvPAD 1 2 ONLY ONLY Code Code 1 Code 2 Code 3 Entry Delay Time 2 CODE NO I PN code code ARM EXIT DELAY Time REX CODE 1 P30E SIREN RESET
81. ded as a guide to the upper limit and should NOT BE USED For compatibility with existing installations the sensitivity levels P31E to P36E are identical to previous versions of D8 D16 o ADJUSTING NESSENSORS Nessensors are sensitive to high frequencies and insensitive to low frequencies Therefore it is not necessary to apply much force to the protected structure rather a very rapid succession of blows The sensitivity has been correctly adjusted when a single blow applied with a soft object e g by hand does not cause an alarm whereas a rapid series of blows using a metal object such as a screwdriver blade will cause an alarm P37E P38E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all off NOTES A Long Response Zone cannot be a Normal Zone or Vibration zone at the same time To convert zone s back to a Normal Zone turn on the required zone s at PSOE RELATED OPTIONS P301E 5E 7E Request To Exit REX PROGRAMMING VIBRATION SENSITIVITY Each zone has individually adjustable sensitivity for connection of Nessensor Vibration Sensors Zone sensitivity is adjusted by toggling zones ON in options P30E to P36E is Normal Sensitivity vibration analyser disabled This is used for normal alarm devices Zone response time 200ms P31 36E are the options for the 6 levels of vibration sensitivities P31E is the most sensitive setting PROGRAMMING SEQUENCE P 30 38 E zones
82. delayed by 1 minute El Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL P66E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Supervision Siren output disabled RELATED OPTIONS P65E Supervised Zones PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Radio Zone Supervision enabled RELATED OPTIONS P65E Supervised Zones P66E 1E 4E Supervision Alerts P66E 5E Wired Zone Supervision P67E Zone Supervision Time P92E 4E D8 Report Supervision P75E 12E D16 Report Supervision THIS OPTION IS AVAILABLE IN D8X D16X V5 2 AND LATER P66E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Supervision Time normal RELATED OPTIONS P67E Supervision Time P66E 8E Supervision Time speedup x10 P66E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Supervision Time normal RELATED OPTIONS P67E Supervision Time P66E 7E Supervision Time speedup x6 P67E PROGRAMMING ZONE SUPERVISION ALERTS SIREN OUTPUT Setting this option turns the Siren output ON when a SUPERVISED ZONE alert occurs The Siren output will remain ON for the duration of the ALARM TIME Set by Option P29E PROGRAMMING SEQUENCE P66E toggles the option ON and OFF OFF Supervision Siren output disabled ON Supervision Siren output enabled ENABLE WIRED ZONE SUPERVISION This option enables Wired Zone Supervision or Radio Zone Supervision PROGR
83. e display and re test the transmitter simply press 3E again or 4E to test any other transmitter Ness D8x D16x Control PANEL INSTALLATION MANUAL RADIO DEVICES OPERATION ALARM Any Ness radio device can operate on any zone Hardwired zones continue to operate in parallel Radio Keys can also operate on radio zones for special purposes but they should normally be used as Radio Codes KEYSWITCH INPUT A Radio Device pro grammed to Zone 8 will still work as an alarm even if the Zone 8 input operation has been changed to Keyswitch operation The P60E 2E and 3E options only affect the Zone 8 terminal inputs VIBRATION Radio device zone signals IGNORE the P30E P38E vibration sensor settings TAMPER REPORT Radio Device Tamper operation depends on the Armed State of the control panel RADIO TAMPER causes the keypad to con tinuously beep and also to flash the RADIO TAMPER and the ZONE identifying the detec tor lights Pressing any key on the keypad or sending a TAMPER RESTORE will clear this warning LOW BATTERY REPORT A low battery gives 10 beeps and flashes the RADIO amp the BATTERY light The ZONE light identifying the radio device is also ON The flashing lights stop when any key on the keypad is pressed or a detector code with no low battery is received Low Battery generates HISTORY and DIALLER reports ONCE only until the low battery is fixed and a restore report is received SUPERVISION If a z
84. ea 1 or Area 2 P318E 1E P328 2E P338 3E are programmed to set reader output to selected Aux output P121E 8E P122E 8E P123E 8E are programmed to set AUX outputs to reader Operation Example Code 1555 activates door associated with AUX 1 READER 1 Code 2555 activates door associated with AUX2 READER 2 Code 3555 activates door associated with AUX3 READER 3 Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL CENTRAL STATION MONITORING MONITORED PREMISES MONITORING STATION TELEPHONE LINE AUDIBLE MONITORING MONITORED PREMISES 1 TELEPHONE LINE ANY TELEPHONE 1 AUDIBLE MONITORING REPORTING FORMAT TABLE DIGIT DIGIT A B ALARM Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 Duress Keyswitch Tamper Panic Keypad Panic Radio Panic Medical alarm Fire alarm Exit from installer program mode External Tamper Internal Panel Tamper Keypad Tamper Radio Tamper Mains Fail Panel Battery Fail RADIO Battery Fail AJA allu CO CO NININININI NIN e Sf st Ll A OO pO PO olal A SINI Hs NI OD on Aoa po DM oy RADIO Supervision Fail CENTRAL STATION MONITORING The Ness D8 and D16 co
85. easy enabling disabling of Day Mode Keypad Panic feature Keypad Duress feature Two button arming feature Fire Alarm feature with different siren tones Highly flexible zone to output mapping Onboard Vibration Sensor Analyser with programmable sensitivity Use with Nessensor vibration sensors Siren chirp and strobe flash on arming with radio key Quiet chirps option on arm disarm by radio key True Dynamic Battery Test actively tests the battery under load every hour 4 programmable auxiliary outputs Automatic reset fuses Programmable siren reset lockout 80 event memory from keypad Standard defaults to suit most applications Easy programming by keypad or NessComms software All programming data is permanently stored in a non volatile memory All inputs and outputs are heavily protected against lightning and high voltage supply transients Optional output expander DIALLER Full remote upload download by PC and modem using NessComms software Remote control of outputs via telephone Contact ID Format Two 14 digit phone numbers plus one follow me number Audible format feature Phone line monitoring activates output Dialler Listen in option for installers Auto Test calls Pulse or DTMF dialling True dial tone detection Hex programmable client codes RELEASE NOTES D8x D16x v5 5 November 2005 Teleph
86. ed OFF 1 short beep SUMMARY OF TELEPHONE COMMANDS 0 Prepare receive commands 1 st Arm Areas 2 Disarm Areas 3 Turn Aux 1 Output ON or OFF 4 Turn Aux 2 Output ON or OFF 5 Turn Aux 3 Output ON or OFF 6 fs Turn Aux 4 Output ON or OFF amp Finished hang up OPERATING THE PANEL BY TELEPHONE The D8 D16 will allow a user to call in to the panel using a standard DTMF telephone and remotely Arm or Disarm all areas and also turn on or off Aux outputs 1 2 3 or 4 To maintain panel security remote operations can only be activated after entering a valid user code To operate the panel by telephone you need a DTMF capable telephone a valid user code and you must know the telephone number of the line to which the panel is connected NOTES e f the panel does not receive commands for periods longer than 10 seconds it will assume that the call is finished and it will hang up f an alarm occurs which requires the panel to dial out while attempting remote control the Panel will treat the alarm as a priority give a constant tone as a warning and then hang up When all remote control commands are finished press to force the panel to hang up SEQUENCE OF OPERATION 1 Phone the panel telephone number and listen for the required number of rings ring ring ring ring and then hang up 2 Wait 10 seconds an
87. elay and separate power supply PROGRAM MODE LEVEL Installer Remote by PC RELATED OPTIONS P59E Aux2 zones RELATED OPTIONS P65E P66E P67E Radio Supervision RELATED OPTIONS P90E 5E Enable remote Aux control P122E 7E RELATED OPTIONS P303E DOTL zones P304E DOTL timer RELATED OPTIONS P318E P328E P338E P319E P329E P339E AUX2 OUTPUT OPTIONS a n x 5 Sets the behaviour of the Aux2 output 8 9 JE y Only one option be selected 2 5 8 c 8 p 5 a a eee ces lee o FAES 2 3 IS 5 lt lt lt 5 65 o 2 E12 zoz T3 Es E 2 o o x Y 5 o 5 2 00 lou loa c ca oOo o jax E o le alealea e 5 O e S lt lee Option Description 1E 2E 3E 4E 5E 6E 7E 8E P122E AUX2 OUTPUT OPTIONS ON PROGRAMMING SEQUENCE P122E 1E 8E Turns an option on Only one option can be on ZONE ALARMS TO AUX2 With this option ON zones selected in P59E will turn on Aux2 when they go into alarm The Aux2 output turns off when the panel is disarmed reset 1E OFF Zone Alarms do not turn on Aux2 1E ON Zone Alarms turn on Aux2 Factory default ZONE SUPERVISION ALARMS TO AUX2 Setting this option turns the AUX2 output ON when a SUPERVISED RADIO alarm is triggered The Aux2 output turns off when the panel is disarmed reset 2E OFF Zone Supervision Ala
88. en programmed as REX inputs for access control purposes P301E 5E 7E To prevent accidental door opening the REX button then must be pressed and held for 1sec or 3sec as programmed PROGRAMMING SEQUENCE P37E or P38E Zone No E toggles zones ON and OFF Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL 17 PROGRAMMING ZONES 1 8 D8 amp D16 ZONES 9 16 D16 Option No Description 12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 P39E DOUBLE TRIGGER zones P40E INSTANT zones ON ON ON ON ON ON ON ON ON ON ON ON ON ON ZONE DELAY TYPES PA1E ENTRY DELAY 1 zones ON Only one option per zone can be selected For example a zone cannot P42E HANDOVER zones ON be instant and delayed at the same PASE ENTRY DELAY 2 zones P44E LOCKOUT zones Reset O P ON ON ON ON ONJ ON ON ON ON ON ON ON ON ON P45E AREA 1 zones ONJ ON ON ON ON ON ON ONJON ON ON ON ON ON ON ON P46E AREA 2 zones P51E MONITOR zones P52E 24HR zones P53E DAY zones TRIGGER ZONES PROGRAM MODE LEVEL Zones programmed to Double Trigger will recognise an alarm condition if Installer Remote by PC The zone has been triggered twice within a 4 minute period FACTORY DEFAULT ia 2 d Ee each trigger once All OFF No Double Trigger zones e zone is left unsealed for longer than 15 seconds NOTES PROGRAMMING SEQUENCE Double Trigger is useful for preventing P3
89. enclosure the antenna wire should protrude outside the enclosure For best performance the antenna wire should be kept straight and not coiled shortened or extended Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL Gi NESS RADIO P101E P116E PROGRAM MODE LEVEL Installer FACTORY DEFAULT No Radio Devices programmed NOTES Radio Device programming is done by learning the code by radio Radio Devices codes can only be deleted by keypad Some Ness Radio Devices send separate Alarm and Restore signals For special purposes radio zones can be also programmed to accept radio keys In this case the zone can not also be programmed to accept a radio device Late model Ness Radio PIRs 100 663 and Radio Reed Switches 100 662 send Supervision signals SUPERVISION RELATED OPTIONS P65E Supervised Radio Zones P66E Radio Supervision Alerts P67E Radio Supervision Time P75E 12E Radio Supervision Fail Report RADIO DEVICES OPTION TABLE Zone 1 P101E Zone 2 P102E i Zone 3 P103E A 20 4 P104E s Zone 5 P105E gt Zone 6 P106E Zone 7 P107E Zone 8 P108E Zone 9 P109E Zone 10 P110E Zone 11 P111E Zone 12 P112E Zone 13 P113E Zone 14 P114E Zone 15 P115E Zone 16 P116E TIP To prevent conflicting radio signals when programming Radio Devices disable each device once you have finished programming it Remove the b
90. er 1 Ore 2 E Enter the telephone number 30 digits maximum followed by E 8 P72E Selects the option for Account Number 1 10 vo E Enter the Account number 4 digits maximum The account followed by E number is supplied by your central monitoring station 11 PE To exit program mode Program light will turn off 12 Ness D8x D16x Control PANEL INSTALLATION MANUAL PROGRAMMING Power up with Program Link OFF Usually on first time installation FACTORY DEFAULTS Master Code 123 Installer Code 000000 we PROGRAM light ds FLASHING INSTALLER PROGRAM Mode PROGRAM PROGRAM LIGHT IS FLASHING INSTALLER PROGRAM MODE Installer Program Mode allows access to ALL program options Note The panel will remain in Installer Program Mode indefinitely PROGRAM light ooh USER PROGRAM Mode PROGRAM PROGRAM LIGHT IS ON INSTALLER CODE CE Factory default Installer Code 000000 USER PROGRAM MODE CP MASTER CODE E User Program Mode allows the Factory default Master Code 123 owner to program All User Codes Entry Exit Times NORMAL OPERATING Mode Follow Me Telephone number PROGRAM LIGHT IS OFF Note The panel will automatically drop out of User Program Mode to Operating Mode if no keypad buttons are pressed for 4 PROGRAM MODE LEVELS TABLE 4 FLOW CHART HOW TO ENTER PROGRAM MODE METHOD 1 FIRST TIME PROGRAMMING FROM POWER UP 1 Power up with the PROG li
91. existing D16 installation where 4K7 resistors have been used on zones 9 16 It may be more convenient to use Zone Split to avoid running extra cables for zones 9 16 Zone Split allows 2 zones to work on 1 zone input NOTE 2 If Zone Split is enabled physical zone 9 16 inputs cannot be used They will become inactive ZONE SPLIT This option splits zone inputs 1 8 into 16 zones using pairs of zones so that there are 16 wired zones available When Zone Split is enabled the physical zone inputs 9 16 are ignored by the panel Zones 1 8 use 2K2 end of line resistors on the Z1 Z8 inputs Zones 9 16 use 4K7 end of line resistors on the Z1 Z8 inputs with Zone 9 connected to the Z1 input etc The monitoring resistors must be wired in parallel making this zone splitting arrangement suitable for Normal Closed N C detectors PROGRAMMING SEQUENCE P68E 1E toggles the option ON and OFF OFF No Zone Split ON Zone split enabled CONNECTION DIAGRAMS EXAMPLE 1 Normally Closed Devices EXAMPLE 3 Normally Closed Devices NESS D16 ZONE 1 DEVICE NESS D16 ZONE 1 DEVICE N C Contacts N C Contacts 22 gt 2K2 gt E NC Contacts Sb AKT gt EXAMPLE 2 Normally Open Devices EXAMPLE 4 Normally Open Device Zone 1 ONLY NESS D16 ZONE 1 DEVICE NESS D16 ZONE 1 DEVICE N O Contacts N O Contacts 2x 2K2 ele B I Sl gn B B 2x22 ZONE 9 DEVICE N C Contacts QD E
92. f dialler test calls to the Central station PROGRAMMING SEQUENCE P89E 1E toggles the option ON and OFF OFF No Test Calls ON Test Calls enabled MAINS REPORT DELAY This option allows Mains Fail reports to be delayed by one hour if the mains power has been off continuously for that time This avoids mains fail reports being sent to the Central Station in the event of brief power failures PROGRAMMING SEQUENCE P89E 2E toggles the option ON and OFF OFF Mains Fail reports immediately ON Mains Fail report is delayed by 1 hour LISTEN IN TO DIALLER This is a diagnostic feature to allow the installer to hear the dialler message and other telephone tones through a horn speaker There are 2 methods of listening to the dialler METHOD 1 Temporarily connect a horn speaker to the LISTEN pins on the main board This method required no programming options to be set the LISTEN pins are always active METHOD 2 This method requires option P89E to be turned on Listen In is enabled for a minimum of 4 minutes after exiting Program Mode During Method 2 Listen In the dialler message and other telephone tones can be heard through the Siren output at low volume while the dialler is sending reports The 4 minute period is restarted whenever any key on the keypad is pressed To turn Listen In off go back into Installer Program mode and toggle the option OFF PROGRAMMING SEQUENCE P89E toggles the option ON and OFF OFF Method
93. f silence This is repeated 3 times and can be stopped by another beep such as keypress If the zone has entry delay you will hear the Smart Beeps sequence once when the zone is triggered and again at the end of entry delay If Entry Beeps are disabled P60E 1E Smart Beeps will only be heard at the end of entry delay Smart Beeps use the keypad s onboard sonalert so option P63E 3E and or 7E must be on to enable the sonalert output for Monitor alarms and Day alarms OFF Smart Beeps disabled Factory default ON Smart Beeps enabled Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL 106 013 Relay Board Connects to AUX header AUXI Separate Power Supply Diode is required to prevent spikes not supplied DOOR STRIKE Power To Open Recommended wiring of an electric door strike using a relay and separate power supply PROGRAM MODE LEVEL Installer Remote by PC RELATED OPTIONS P58E Aux1 zones RELATED OPTIONS P65E P66E P67E Radio Supervision NOTES When this option is enabled the Radio Key s Panic button will no longer sound alarms or report to the dialler NOTES When this option is enabled the Radio Key s Panic button will no longer sound alarms or report to the dialler RELATED OPTIONS P90E 5E Enable remote Aux control P121E 7E RELATED OPTIONS P303E DOTL zones P304E DOTL timer RELATED OPTIONS P318E P328E P338E P319E P3
94. he end of the dialling of the last digit it will wait for 5 seconds and then commence the audible message the audible message will continue to repeat for 45 seconds or until it is kissed off by a DTMF tone If there is more than one alarm message to transmit then after it has received the Kiss off Acknowledge tone it will commence transmission of the next message The panel will continue to do this until all alarm messages are transmitted and Kissed off ACKNOWLEDGE TONE The person receiving the call can then acknowledge the alarm by pressing the st key on their telephone Press the key for 2 seconds during pauses in the audible message On mobile phones press the st key in short bursts Many mobile phones enter sub menus if the key is pressed continuously If the alarm is not acknowledged the keypad s LINE light will flash continuously until the panel is next armed ALARM EVENTS SENT The Reporting Format Table identifies the alarm events which can be programmed to be sent in Audible Format Open Close reports Restorals and Exclusions Isolates are NOT sent in Audible Format even if selected on ul Ness D8x D16x Control PANEL INSTALLATION MANUAL AUDIBLE FEEDBACK JJJ The User Code is valid 3 beeps Successful Arming or Disarming An Auxiliary output has been turned ON Panel is already Armed JI L 1 long beep Invalid code Try again J An Auxiliary output has been turn
95. he zone will not trigger the Reset output Zone No ON The zone will trigger the Reset output STROBE OUTPUT ZONES Selects the zones to trigger the Strobe output PROGRAMMING SEQUENCE P55E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger the Strobe output Zone No ON The zone will trigger the Strobe output KEYPAD SONALERT ZONES Selects the zones which will sound the Keypad Sonalert beeper PROGRAMMING SEQUENCE P56E Zone No E toggles the options ON and OFF Zone No OFF The zone will not trigger the Keypad Sonalert Zone No ON The zone will trigger the Keypad Sonalert A Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL P57E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All ON All zones trigger Siren output NOTES OE will turn all selections OFF MEMORY E will turn all selections ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All OFF No zones trigger AUX1 NOTES OE will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P121E 5E 8E Day zone output mapping PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All OFF No zones trigger AUX2 NOTES OE will turn all selections OFF MEMORY E will turn all selections ON PROGRAMMING SIREN OUTPUT ZONES Selects the zones to trigger the Siren output PROGRAMMING SEQUENCE P57E Zone No E toggles the options ON and OFF Zone No O
96. ht stays on and a warning beep sounds the access card is already assigned to another user code and must be cleared from that user code first Once a card is programmed to a user code it can be used to ARM THE PANEL To allow arming with a double read enable option P301E 2E To allow arming with a single read and pushbutton enable option P301E SE Both methods can be enabled at once DISARM THE PANEL To allow disarming single read enable option P301E 4E This option can be enabled if necessary A user may be allowed to arm by access card but not disarm or vice versa OPERATE AUX OUTPUT S To allow the operation of panel AUX outputs by access card the reader to which the card is assigned must be programmed to operate one of the four AUX outputs First enable one or more AUX outputs to be a Reader output P121E 8E P122E 8E P123E 8E and P124E 8E Next assign which reader will trigger which AUX output Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL ACCESS CONTROL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Use one reader NOTES When using multiple readers this option must be enabled before programming any access cards to avoid losing card programming when the option is enabled PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES When this option is enabled z
97. ice number is indicated by zone lights OPERATION SUMMARY OPERATION by KEYPAD by RADIO KEY by ACCESS CARD or FOB to ARM Press E Present a Card or Fob The panel must initially be If the Armine Sronrcur is enabled P62E 5E twice if P301E 2E is disarmed P on or press User Cope E Or present a Card or Fob once press E button if P301E is on or press User Cope If Cope AnuiNG has been enabled for that user code Extra Option 4E to DISARM To disarm and or reset 1 Present a Card or Fob alarms Press User Cope E WA once if P301E 4E is on to arm MONITOR MODE Press E Areal must initially be If the Monitor Suonrcur is enabled 62 disarmed Monitor Mode Gani be Press either the OFF Or press the AUX button used if the panel is fully button or the ON button once If P120E 3E is on disarmed or if only Area2 twice within 4 seconds RK4 radio key only is armed see page 20 for PG9E 5E must be on more information OF press User Cove u Radio Key Monitor Arm chirps be enabled by option P120E 2E off by default PANIC alarm NS Press QD C xD star keys together or press D User Cope E or press D E Press and hold the PANIC button for at least 4 sec If KevPApD Panic is enabled P62E 4E KEYPAD DURESS Press 5 6 8 on 9 User Cove Keypad Duress allows Add one these digit
98. ight will turn off QUICK START 2 STEP KEYSTROKES DESCRIPTION COMMENT 1 123 Enters User Program Mode Program light will turn on P000000E Enters Installer Program Mode Program light will flash P201E Selects the option for User Code 1 The existing code will be displayed on the keypad one digit at a time 4 zo Enter your new PIN code followed Keypad codes can be 3 to 6 digits by E in length 5 7 2 iB Enter your new PIN code again The new code will be displayed on the keypad one digit at a time P86E4E Turns on option P86E 4E Enables Audible Monitoring P70E Selects the option for Telephone Number 1 8r iMi zi c m E Enter the telephone number 30 digits maximum followed by E 9 PE To exit program mode Program light will turn off QUICK START 3 STEP KEYSTROKES DESCRIPTION COMMENT 1 P123E Enters User Program Mode Program light will turn on P000000E Enters Installer Program Mode Program light will flash P201E Selects the option for User Code 1 The existing code will be displayed on the keypad one digit at a time 4 SE Enter your new PIN code followed Keypad codes can be 3 to 6 digits by E in length 5 Enter your new PIN code again The new code will be displayed on the keypad one digit at a time P86E2E Turns on option P86E 2E Enables Contact ID format P70E Selects the option for Telephone Numb
99. is disarmed P62E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Siren burst on Auto Exclude enabled RELATED OPTIONS P6OE 6E Auto Exclude zones P62E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Exit Time x10 disabled RELATED OPTIONS P28E Exit Time PROGRAMMING gt o a 2 a DEOS E o I lt 5 tc O Q lt lt 5 llela 8 616 sg a NI lalz A cS cH elella r t pel Tem t e S Silalelelelsl lele llls o o o o o o N Option No Description 1E 2E 3E 4E 5E 6E 7E 8E P62E OPERATION SHORTCUTS ETC SYSTEM OPERATION SHORTCUTS Some keypad operations can be programmed to operate with or without a User Code PROGRAMMING SEQUENCE P62E 1E 6E 1000 65 the options ON and OFF 1E ON Memory Display shortcut 2E ON Zone Exclude shortcut 3E ON Monitor Mode shortcut 4E ON Keypad Panic shortcut 5E ON Area1 Arming shortcut 6E ON Area2 Arming shortcut OPERATING EXAMPLES Arming without shortcut User Code Arming with shortcut E Keypad Panic without shortcut 2 User Code Keypad Panic with shortcut Cx E SIREN BURST ON AUTO EXCLUDE This option allows the disabling of the 2 second siren burst at the end of Exit Time which indicates a zone s has been Auto Excluded
100. l override any other zone type setting such as Instant Delayed or Handover 24hr zones are independent of Area operation All other zone types must be assigned to at least one Area to become active PROGRAMMING SEQUENCE P52E Zone No E toggles the options ON and OFF Zone No OFF The zone is not a 24hr zone Zone No ON The zone is a 24hr zone DAY ZONES Day Zones operate when the panel is fully disarmed i e when Area 1 Area 2 and Monitor are all off When alarmed these zones will activate their assigned outputs instantly The outputs mapped to the Day Zone will turn on while the zone is unsealed Turn P64E 2E on to limit Day Zone alarms to 2 seconds The Temporary Day Zones feature allows day mode to be easily enabled disabled and day zones added removed by the user from any keypad PROGRAMMING SEQUENCE P53E Zone No E toggles the options ON and OFF Zone No OFF The zone is not a Day zone Zone No ON The zone is a Day zone See page 20 for information on TEMPORARY DAY ZONES Ness D8x D16x Control PANEL INSTALLATION MANUAL PROGRAMMING Zone To Output Mapping applies to zones when the panel is in the Armed or 24hr state For MONITOR and DAY mode Output Mapping see Option 6 1E 8E page 28 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All ON All zones trigger Reset output NOTES OE will turn all selections OFF MEMORY E will turn all selections ON PROGRAM MOD
101. led See page 20 for more information on Temporary Day Zones Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL ul PROGRAMMING QUICK START 1 LOCAL SYSTEM Quick Start 1 shows you how to change User Code 1 the Master Code QUICK START 2 AUDIBLE MONITORING Quick Start 2 shows you how to change User Code 1 the Master Code enable Audible Monitoring and program a telephone number This will enable the dialler to report alarms to any telephone including mobile phones QUICK START 3 CENTRAL STATION MONITORING Quick Start 3 shows you how to change User Code 1 the Master Code enable Central Station Monitoring and program one telephone number This will enable Default Master Code is 123 Default Installer Code is 000000 QUICK START PROGRAMMING Use one of these programming summaries for fast setup of your Ness D8 or D16 control panel as a Local Audible Monitored or Central Station Monitored system QUICK START 1 STEP KEYSTROKES DESCRIPTION COMMENT 1 123 Enters User Program Mode Program light will turn on 2 P201E Selects the option for User Code 1 The existing code will be displayed on the keypad one digit at a time 3 Enter your new PIN code followed Keypad codes can be to 6 digits by E in length 4 Enter your new PIN code again The new code will be displayed on the keypad one digit at a time 5 PE To exit program mode Program l
102. ller Remote by PC FACTORY DEFAULT 60 seconds NOTES Programmable from 10 990 seconds PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT 6 60 seconds NOTES Programmable from 1 99 seconds RELATED OPTIONS P62E 8E Exit Time x10 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 5 minutes NOTES Programmable from 1 99 minutes Siren times of longer than 5 minutes are contrary to noise pollution regulations in most areas Option No Description Default Note P26E ENTRY DELAY TIME 1 20 seconds P27E ENTRY DELAY TIME 2 6 X10 60seconds 28 EXIT DELAY TIME 60 seconds P29E SIREN RESET TIME 5 minutes ENTRY DELAY TIME1 The Entry Delay Time 1 is the time given to Disarm the Panel after a Entry Delay 1 zone is unsecured The Entry Delay Time1 setting is from 1 to 99 seconds PROGRAMMING SEQUENCE P26E existing time is displayed one digit at a time ENTER NEW TIME E new time is displayed one digit at a time EXAMPLE To program Entry Delay Time1 to be 30 seconds P26E 30E ENTRY DELAY TIME2 The Entry Delay Timez is the time given to Disarm the panel after an Entry Delay2 zone is unsecured The Entry Delay Time2 setting is from 10 to 990 seconds 1 99 Note The Entry Delay Time2 is set 10 second increments so that a value setting of 6 means a 60 seconds delay PROGRAMMING SEQUENCE P27E existing time is displayed one
103. ller Mode ON P75E 8E P77E 8E P75E 8E P77E 8E Radio Tamper ON ON P92E 1E 9 1E P75E 9E P77E 9E Radio Panic ON ON P92bE 2E P93E 2E P75E 10E P77E 10E Radio Battery ON P92E P93E P75E 11E P77E 11E Supervision fail ON P92E P93E 4E P75E 12E P77E 12E Panel battery ON P92E 5E P93E 5E P75E 13E P77E 13E Mains fail ON P92E 6E P93E 6E P75E 14E P77E 14E not used ON P92E 7E P93E 7E P75E 15E P77E 15E not used ON P92E 8E P93E 8E P75E 16E P77E 16E REPORT MISCELLANEOUS ALARMS REPORT MISCELLANEOUS RESTORALS These options select which Miscellaneous alarms will trigger the dialler to send Alarm reports and Restoral reports to the Central Station Alarms if enabled are sent on activation Restorals if enabled are sent on Opening Mains Fail and Low Battery Restorals are sent when the power has been restored Note the different program option numbers for the D8 and D16 PROGRAMMING SEQUENCE PxxE 1E 8E or 1E 16E toggles the option ON and OFF m Send immediately Send after siren time Send after disarm amp seal N m e m Option No Description 5E 6E 7E 8E Send after disarm always P82E ZONE RESTORAL REPORTING OPTIONS RESTORAL REPORTING OPTIONS This option selects when the dialler sends zone Restoral reports Only one of the following options may be selected Restoral reporting options also apply to 24hr zones PROGRAMMING SEQUENCE P82E 1
104. method of programming user codes for easier assignment of options to user codes Each user code can be assigned to Area1 Area2 Code Only Arming Arm Only Keypad Code Radio Code Access Code Reader1 2 or 3 Automatic Memory Mode exit after 4 minutes without a keypress Same as User Program mode and Exclude mode Monitor Mode can now be armed when Area2 is armed Monitor Mode is still unavailable when Area1 is armed The Keyswitch input can now use a latching 2 position keyswitch or momentary action keyswitch Keyswitch input can also be programmed to Arm Only or Disarm Only Siren can be enabled to chirp when Monitor arming with a Radio Key as well as chirp when full arming with a Radio Key Arming of Monitor Mode with the AUX button on a RK4 Radio Key Monitor Mode alarms are mapped to RESET and STROBE outputs by default Real Time Clock onboard with programmable Minutes Hours Day Month Year Day Of Week Any zone can be a Long Response Zone with an input delay of 1sec or 3sec Replaces vibration sensitivities 7 amp 8 Vibration sensitivity settings are now 6 levels per zone previously 8 New Enable Hardwire Zones option allows zone inputs to be disabled if unused The Ness Output Expander is now also an option for the D8 control panel Previously D16 only The D16 now has 16 physical zone inputs using 2K2 resistors Zone Split is still available as a programmable option If Zone Split i
105. ms only E 2 a b Se g o Q o 3 N 5 amp lsels litizis amp slsls zz prm ese naja ol 2a o0 2 o o9 ae Se e 53 298 Sed SIS EM 2e e g amp leololo s 5 a a ES 2 2 eee el w l olals e lala NC E r a lt Option Description 1E 2E 3E 4E 5E 6E 7E 8E P60E VARIOUS OPTIONS ON ON ON ENTRY BEEPS The sonalert will beep during Entry Delay PROGRAMMING SEQUENCE P60E 1E toggles the option ON and OFF OFF Entry Beeps OFF ON Entry Beeps ON KEYSWITCH OPERATION An externally fitted normally open momentary Keyswitch can be used to Arm Disarm or arm the Monitor mode The keyswitch is wired to zone 8 zone 8 is then no longer available as a normal alarm input but is still available for use as a Radio Zone PROGRAMMING SEQUENCE P60E 2E or toggles the option ON and OFF 2E amp 3E OFF No keyswitch operation Zone 8 is a normal alarm input 2E ON Keyswitch cycles between Monitor and Disarm 3E ON Keyswitch cycles between Arm and Disarm 2E amp 3E ON Keyswitch cycles between Arm Monitor and Disarm C oy ee Momentary Momentary Momentary Latching Keyswitch Keyswitch Keyswitch Keyswitch P60E 2E is ON P60E is ON P60E 2E is ON P120E 1E is ON P60E is ON KEYSWITCH WIRING If PGOE or 4E are enabled use a momentary action keyswitch with normally open
106. n sends day alarms to the AUX 2 output P63E 7E Day Mode to Sonalert P63E 8E Day Mode to Siren output P53E Permanent Day Zone selection Temporary Day Zone selections will be lost if the panel is powered down or reset but are not affected by arming disarming or entering program mode Ej Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL P47E P48E P49E P50E See page 14 15 programming User Codes PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT all OFF No Monitor zones NOTES By default all Monitor zones have Entry Delay2 see P64E 3E If this option is off Monitor zones have normal entry delay attributes set by options PAOE P42E RELATED OPTIONS P63E Monitor Mode output mapping P64E 1E Brief Monitor alarm P64E 3E Monitor zones have Entry Delay2 P69E 3E Quiet Monitor siren P69E 5E Radio Key ON or OFF button arms Monitor Mode P120E 2E Monitor arm chirps by radio key P120E 3E Radio Key AUX button arms monitor mode P120E 6E Smart Beeps for Monitor and Day zones PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All OFF No 24hr zones NOTES The Tamper input is always a 24hr zone For silent 24hr zones deselect the zone s from options P54E P57E Reset Strobe Sonalert amp Siren To change a 24hr zone to any other zone type the zone must also be re assigned to an AREA P45E or P46E PROGRAM MODE LEVEL Installer Remote by PC FACTO
107. ne type in the DELAY GROUP ENTRY DELAY2 ZONES When an Entry Delay2 zone is triggered it has entry delay as set by the Entry Delay Time2 P27E PROGRAMMING SEQUENCE P43E Zone NoJE turns the options ON P43E Zone ON The zone is an Entry Delay2 zone To deselect the option select a different zone type in the DELAY GROUP RESET LOCKOUT ZONES All zones and tamper input can be programmed to Lockout i e cause the RESET OUTPUT to sound only once whilst the panel is armed The RESET OUTPUT is then locked out for that alarmed zone until entering a valid code has reset the panel If using area partitioning disarming either partition resets the zone lockout for both partitions PROGRAMMING SEQUENCE P44E Zone toggles the options ON and OFF P44E Zone OFF The zone is not a Lockout zone P44E Zone ON The zone is a Lockout zone ASSIGNING ZONES TO AREAS ZONES 1 8 D8 amp D16 ZONES 9 16 D16 Option No Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 P45E AREA 1 ZONES ON ON ON ON ON ON ON ONJON ON ON ON ON ON P46E AREA 2 ZONES ASSIGNING ZONES TO AREAS Assign or remove zones that will operate in Area 1 and or Area 2 P45E P46E PROGRAM MODE LEVEL Installer Remote by PC PROGRAMMING SEQUENCE P45E Zone toggles the options ON and OFF for 1 ie ea Aria Zone No OFF The zone is not in 1 9 Z
108. necting Ness sirens piezo sirens or relays etc This output will reset at the end of siren time P29E or whenever the panel is reset whichever comes first A maximum of 3 x 12V piezo screamers Ness Part No 100 238 100 004 or 2 X Ness Piezo Part No 100 172 can be connected to this output This output is protected by an Automatic Reset fuse AUX HEADER The Aux outputs are open collector outputs switch negative which can supply a maximum of 100mA Each Aux output can be programmed to perform one of several different functions Aux1 Programmed by option P121E 1E 8E Aux2 Programmed by option P122E 1E 8E Aux3 Programmed by option P123E 1E 8E Aux4 Programmed by option P124E 1E 8E 12V 12V DC output Maximum current draw 100mA OV 12V ground OUTPUT FUSING The 12V outputs Siren Reset and Strobe outputs are protected by Automatic Reset elec tronic fuses These outputs will automatically reset once the overload is removed BACKUP BATTERY A properly charged battery must be installed to ensure the Siren Strobe and Reset outputs operate correctly SIREN LOAD A maximum output of 2 0A continuous is available from the SIREN and RESET outputs and 200mA from the STR output Recommended maximum power load 3 x Horn speakers SIREN output 2 x Strobe lights STR output 2 x Ness Internal Sirens 100 172 RESET output Note This assumes no more than 500mA is being drawn from the 12V device outputs Ness D8x
109. nk OFF The PROG link or Box Tamper lead must be ON in Operating Mode d METHOD 2 USING THE KEYPAD TO ENTER PROGRAM MODE QQ 7S BIO The panel must be Disarmed 9 0 1 Press P MASTER CODE The keypad will respond with 3 beepselele This is User Program Mode PROGRAM light is ON 2 Press P INSTALLER cone CE The keypad will respond with 3 4 This is Installer Program Mode PROGRAM light is FLASHING HOW TO EXIT PROGRAM MODE 1 Press P then Exits directly to Operating Mode PROGRAM light is OFF Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL 13 PROGRAMMING P101E P116E P201E P256E PROGRAM MODE LEVEL User Installer Remote by PC except radio keys and access cards FACTORY DEFAULT User Code 1 123 All other codes blank NOTES 1 To clear all codes except the Installer Code enter P98E in Installer Program mode This also defaults user code 1 to 123 See Page 51 2 Open Close reports are identified by user number when the control panel is base station monitored RELATED OPTIONS Installer Code See Page 13 How To Enter Program Mode Page 53 Programming The Installer Code Installer Code default 000000 RELATED OPTIONS Programming Radio Codes page 62 IMPORTANT NOTES O A User Code can bea Keypad Code Radio Code or Reader Code but only one type at any one time Any user codes not assigned to be Radio Codes or Reader
110. not be used for any other purpose IF ALL 16 ZONES D16 and the AUX outputs are required then 2 Expanders are needed in which case select this option so that it best suits the installation wiring Output Expander Output Expander 106 011 16 15 14 13 12 11 109 8 7 6 5 4 3 2 112V E Eo oc Ac ICE 2I 3 4c E A Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL Q Re S fio 5 fg S io 10 2 2 a aE TNI g oO gt e c 2 lt Option Description 1E 2E 3E 4E 5E 6E 7E 8E P117E OUTPUT EXPANDER OPTIONS ENABLE OUTPUT EXPANDER Selecting this option enables the optional 106 011 Output Expander When this option is enabled the J5 connector on the main board will only drive the Output Expander All AUX outputs are available on the Output Expander See the table below for a description of each output PROGRAMMING SEQUENCE P117E 1E toggles the option ON and OFF OFF No Output Expander ON Output Expander enabled ALTERNATE EXPANDER FORMAT Selecting this option changes the alarms on the 1st and 2nd Output Expander With the option OFF Zone 1 to Zone 16 are on the 1st Expander The AUX ARM and other outputs are on the 2nd Expander Use this option when only Zone outputs are required and only one Expander is used With the option ON Zones 1
111. not sealed or unsealed during the Supervision Time then the programmed alerts will turn on as programmed by P66E 1E 4E P92E 4E or P75E 12E Zone Supervision can be used as an inactivity monitor to sound an alert or send a dialler report if a zone has had no activity during a set period of time For example to monitor an aged person s home Azone which is permanently in a sealed or unsealed state for the duration of Supervision Time will be treated as a Supervision alarm If P66E 5E is on Zone Supervision acts on wired zones If P66E 5E is off Zone Supervision acts on radio zones Each Supervised zone has its own supervision timer Zone Supervision is independent of the armed state of the panel Zone Supervision can be temporarily disabled by Excluding the zone s The zone which caused the Supervision alarm flashes on the keypad Entering a valid code E will reset Supervision alarms e If Radio Supervision is enabled P66E 5E off then radio zones are supervised for the absence of a supervision signal as opposed to inactivity of a zone in Wired Supervision mode P66E 5E on PROGRAMMING SEQUENCE P65E Zone No E toggles the options ON and OFF Zone No E OFF The zone is not a Supervised Zone Zone No E ON The zone is a Supervised Zone ZONE SUPERVISION ALERTS SUPERVISION TIME SPEEDUP See pages 32 33 SUPERVISION TIME SUPERVISION TIME sets the time interval before an inactive Supervised Zone triggers a Super
112. ns Power is off The panel s backup battery is low Normal EXCLUDE Normal TAMPER Normal Memory Mode selected New alarms in memory Zones are excluded Tamper alarm Indicates that a Radio Key A RADIO Normal Receiving radio signal other radio device has a low battery Phone line fault or LINE Normal PROGRAM Normal failure to communicate Not Ready Dialler is on line User Program Mode Installer Program Mode Ready to Arm Not ready to Arm MEMORY MODE EVENTS INDICATED BY KEYPAD LIGHTS LIGHT MEMORY EVENT Zone lights 1 8 or 1 16 Zone alarm no lights Panel Disarmed ARMED Panel Armed or Area 1 Armed ARM Area 2 Armed MAINS c ne Mains power failure BATTERY sese Low Battery TAMPER ertt Tamper alarm Siren cover panel etc Panic alarm AI ice res Telephone line fail RADIO EXCLUDE Radio Key Panic alarm RADIO BATTERY ZONE Radio Device battery low Device number is indicated by zone lights RADIO BATTERY ARM Radio Key battery low Radio Key number is NOT indicated RADIO TAMPER ZONE RADIO MONITOR ZONE Radio Supervision alarm Device number is indicated by zone lights MONITOR ZONE Wired Zone Supervision alarm Zone number is indicated by zone lights Radio Device tamper alarm Dev
113. ntrol panels have an on board digital dialler which can send detailed alarm messages to a central monitoring station The digital messages can include information about the zone s which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who arm and disarm the system Central station monitoring is highly recommended and is the most effective method of monitoring your alarm system Installers are welcome to contact Ness for further information about monitoring AUDIBLE MONITORING While Central Station Monitoring is recommended the panel can also send audible alarm reports to any DTMF capable telephone The types of alarms sent are listed in the Reporting Format Table The basic audible message takes the form of N pause A pause B pause N The first digit of the Account Number P72E can be the digits 1 9 If P72E starts with O N is not sent A First digit of the Alarm identifier See Reporting Format Table B Second digit of the Alarm identifier See Reporting Format Table MESSAGE EXAMPLE AUDIBLE PULSE FORMAT P86E 4E If the Account Number is 1234 and zone 5 alarm is reported beep pause beep beep beep beep beep 1 Beep 5 Beeps zone 5 1st digit of the account number REPORTING SEQUENCE When triggered by an alarm event the panel will call the Primary Telephone Number or the Follow Me Telephone Number if programmed and at t
114. o Manual Exclude Reports ON Manual Exclude Reports enabled AUTO EXCLUDE REPORT Enables Auto Exclude Reports for Zones Zones not sealed on arming will be reported as Auto Excluded PROGRAMMING SEQUENCE P88E 8E toggles the option ON and OFF OFF No Auto Exclude Reports ON Auto Exclude Reports enabled Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING P89E 1E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Test Calls enabled RELATED OPTIONS P83E Test Call Interval P84E Time before next Test call P87E 4E Number Of Dialling Attempts P89E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Mains Fail report is delayed P89E 3E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Listen In NOTES Use METHOD 1 if you already have the panel box open and have a spare horn speaker on hand Use METHOD 2 if the box is closed and you need to quickly listen in to the dialler Keep in mind that the dialler tones will be heard via any horn speaker s connected to the Siren output P ssl cee 218 12 Kom BN Sca E e e 4s Es 3 1 s o e D LL fe mos RE 8 mj ale a Option No Description 1E 2E 3E 4E 5E 6E 7E 8E P89E MISC REPORTING OPTIONS ON ON ENABLE TEST CALLS This option enables the reporting o
115. of assigning any access reader to any Aux output for operating door strikes magnetic locks etc Readers can be assigned to multiple outputs Always use an external relay board 100 719 on each Aux output if connecting devices which draw more than 100mA P318E 1E 4E P318E 1 4 Toggles the options 1E ON Reader 1 output to 1 P121E 8E must also be on RELATED OPTIONS 2E ON Reader 1 output to Aux2 P122E 8E must also be on P121E 8E P122E 8E P123E 8E 3E ON Reader 1 output to Aux3 P123E 8E must also be on P124E P319E P329E 4E ON Reader 1 output to Aux4 P124E 8E must also be on P328E 1E 4E P328E 1b 4E Toggles the options 1E ON Reader 2 output to 1 P121E 8E must also be on P123E 8E 2E ON Reader 2 output to Aux2 P122E 8E must also be on P124E 8 E za Sa 5 E 3E ON Reader 2 output to Aux3 P123E 8E must also be on 124E 8E P319E 29 P339E 4E ON Reader 2 output to Aux4 P124E 8E must also be on P338E 1E 4E P338E 1E 4E Toggles the options 1E ON Reader output to 1 P121E 8E must also be on ETE pA le P123E 8E 2E ON Reader 3 output to Aux2 P122E 8E must also be on P124E 8E P319E P329E P339E 3E ON Reader 3 output to Aux3 P123E 8E must also be on 7 4E ON Reader 3 output to Aux4 P124E 8E must also be on P319E P329E P339E READERS 1 3 OUTPUT TIME This sets the time that the outputs selected by P318E P328E and P338E are
116. oid electrostatic build up 1 Use a foot strap a wrist strap or a grounding mat The aim is to connect the body to earth to discharge static before it builds up The connection is a high resistance for personnel safety If the above is not available then it is advisable to wear clothing that will minimise the build up of static Handle circuit boards by the edges Avoid touching any components on the board as the integrated circuits in particular are not guaranteed by their manufacturers to be safe from ESD To minimise the build up of static avoid walking around as much as possible while working on the installation Touch an earthed object to discharge any static before working on the installation RADIO RECEPTION In cases where radio reception needs to be improved the optional 100 200 Radio Interface can be installed up to 50 metres away from the control panel Use 14 0 20 SHIELDED cable or equivalent The shield can either be connected to the EARTH terminal or left unconnected Leave the shield unconnected at the receiver end INSTALLATION PROCEDURES The location of the main panel housing and all keypads should be in an area that is within the protected area of the premises A linen closet or cupboard are good examples as these are generally located in the centre of the premises Positioning of the movement detectors should be considered as the incorrect position may cause unwanted alarms Remove the ho
117. on DOTL alerts will be sent to the optional Output Expander on the same output number as the DOTL zone number P305E 1E settings apply 2E OFF No DOTL Alerts to the Output Expander Factory default 2E ON DOTL Alerts sent to the Output Expander DOTL ALERTS TO KEYPAD With this option on DOTL alerts will SLOWLY Flash the corresponding zone light on the keypad P305E 1E settings apply 5E OFF No DOTL Alerts to the Keypad Factory default 5E ON DOTL Alerts slow flash zone lights on the Keypad Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL ACCESS CONTROL READER 1 to Aux1 READER 1 to Aux2 READER 1 to Aux3 READER 1 to Aux4 READER 2 to Aux READER 2 to Aux2 READER 2 to Aux3 READER 2 to Aux4 m N m m A m Option No Description m N m m A m Option No Description P318E READER 1 TO AUX OUTPUTS P328bE READER 2 TO AUX OUTPUTS READER 8 to Aux1 READER to Aux2 READER 3 to Aux3 READER 3 to Aux4 Option No Description Default Note P319E READER 1 OUTPUTTIME 5 01 24 sec Option No Beseription AEN Ee SES P329E READER2OUTPUTTIME 5 01 24 sec P338E READER 3 TO AUX OUTPUTS P339E READER 3 OUTPUTTIME 5 01 24 sec PROGRAMMING SEQUENCE P338E 1E 4E toggles the options ON and OFF PROGRAM MODE LEVEL Installer Remote by PC READERS 1 3 to AUX OUTPUTS 1 4 These options give the flexiblity
118. one 8 is automatically disabled as an alarm zone PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON 1 5 7 PROGRAM LEVEL Installer Remote by PC FACTORY DEFAULT OFF NOTES When one of these options is enabled that zone is automatically disabled as an alarm zone The zone must reseal before another Request To Exit can occur i e If the zone is left unsealed the door will not be left unlocked RELATED OPTIONS P37E P38bE Long Response Zones P318E P328E P338E P121E P124E Programming of Readers to Aux outputs lez 2 33 Got sa 99 Eg Eg S8222 Option No Description 1E 2E 4E P301E ACCESS CONTROL OPTIONS ON USE READER ADDRESSES If ON then all readers connected to the D8x D16x must have set addresses of 1 2 or 3 The data is then sent in an extended format that includes the reader address Use up to three Ness prox readers The reader s address is determined the connection of the violet wire See the wiring diagram on page 69 If this option is off one standard Weigand 26bit reader can be used The reader s actions are determined by the P318E P319E Reader 1 options PROGRAMMING SEQUENCE P301E 1E toggles the option ON and OFF OFF Do not use Reader addresses ON Use Reader addresses ARM WITH DOUBLE READ When this option is enabled the panel will arm if the same valid access card is
119. one No ON The zone is 1 NOTES P46E Zone toggles the options ON and OFF for Area2 Zone No OFF The zone is not in Area2 Zone No ON The zone is in Area2 EXAMPLE To program zones 1 4 for Area 1 and zones 1 5 8 for Area 2 If no Area operation is required assign In this example we have assigned zone 1 to both areas so it becomes a Common all zones to Area 1 This is also the Zone factory default For options P45E and P46E Zone No E toggles the selection ON and OFF Zones assigned to BOTH areas become Common zones P45E use the Zone No E sequence to turn ON only zones 1 4 P46E use the Zone No E sequence to turn ON zone 1 and zones 5 8 Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING AREA PARTITIONING DEFINITION Area Partitioning allows the control panel zones to be split into two partitions Area1 and Area2 The panel then effectively oper ates as two separate systems sharing only the siren outputs and dialler COMMON AREA ZONES Zones assigned to both Areas are armed only when Area1 and Area2 are both armed This allows the Common Area zone s to be shared by both Areas For example Office A and Office B operate as separate areas but the entrance foyer used by both offices is assigned to both areas meaning it will automatically arm when both Areas have armed The Common Area then automatically disarms when either Area1 or Area2 disarms
120. one has the P65E option ON and a radio code has been programmed for that zone then the supervision is active This means that the radio detector does not need to have its SUPER enabled via header link for the SUPERVISED timeout to occur Useful as an inactivity alarm A zone supervision failure always flashes the identifying ZONE light and the RADIO light RADIO SUPERVISION The purpose of Radio Supervision is to verify the correct operation of Ness Radio PIRs The Supervision signal from the Radio PIR tells the panel that the device has not been removed from radio range and is in working order Non SUPERVISION Radio PIRs can also be programmed and used with the SUPERVI SION TIMERS A non SUPERVISION enabled Radio PIR will transmit signals to the panel only when it has detected an event Obviously there is no guaranteed signal period In either case when the allowed time limit is exceeded then a WARNING is first given if programmed by P66E 3E and then after 1 minute the programmed RADIO SUPERVI SION ALERTS are generated by the panel NOTE Manually Excluding a Supervised Zone will also disable Radio Supervision for that zone NESS RADIO DEVICES Radio Events Table SIGNAL TYPE RKP RADIO KEYPAD O oo LS 2 Z RK1 RADIO KEY PENDANT RK3 RADIO KEY 3 BUTTON NESS RADIO RK4 RADIO KEY 4 BUTTON R12 RADIO PIR R15 RADIO PIR ta m RR1 RR2 RADIO REED SWITCH RPB R
121. one numbers can now be up to 30 digits in length previously 15 digits New option P124E 5E enables AUXA as Fail To Communicate output to trigger backup communications devices such as GSM D8x D16x v5 3 amp v5 4 September 2005 REX User Codes Enabling a user code to Code Only Arm allows the code to be used as a Request To Exit code for access control P64E 4E Radio Key Siren Chirps will now also chirp siren on Monitor disarm P301E 8E new option to enable disable strobe flash on arming disarming by access control Reader previously this function was always on e or 0 E will now delete codes in User Program Mode This previously functioned only in Installer Program Mode Changed operation of event memory Normal Arming Disarming events are not repeated in memory to prevent memory being filled with identical arm disarm events D8x D16x v5 2 June 2005 All user codes are now allocated to Area 1 by default User codes can be allocated to Area 2 as required Area 2 only User codes do not turn off Monitor mode Previously any user code would disarm Monitor mode This allows Area 2 to be armed disarmed without affecting Monitor arming New option P66E 5E enables Wired Zone Supervision Useful as an Inactivity Monitor See page 33 Radio zones will reseal in the presence of high frequency radio interference D8x D16x v5 November 2004 The number of User Codes has been increased to 56 New
122. ons Area 1 must be OFF Area 2 must be armed first and then Monitor armed not the reverse Zones assigned to both Monitor mode P51E and to Area 2 P46E will act as Monitor zones when both Area 2 and Monitor are armed Zones must be assigned to P51E to allow Monitor arm Note Monitor arming when AREA 2 is armed cannot be done by Radio Key double OFF button or by keyswitch Note Monitor Mode is not available when Area 1 is armed Zones The selected zones are indicated by the corresponding zone number Permanent Day Zones set by installer option P53E are not displayed in selection mode Permanent Day Zones can be selected as Temporary Day Zones but this has no effect as those zones are already day zones E Saves changes and returns to normal operating mode 0 Enables and Disables Day Mode This enables disables both Temporary and Permanent Day Zones When Day Mode is enabled any unsealed day zone will sound the programmed output for 2 seconds When Day Mode is disabled an unsealed day zone will simply be indicated on the keypad as an unsealed zone Note The keypad does not indicate if Day Mode is enabled or disabled AUX 2 OPTION When the Temporary Day Zone feature is enabled the installer option P63E 6E selects Aux 2 output instead of the strobe output This allows a remote warning MONITOR MODE Monitor Mode or Home Mode allows selected zones to be armed whilst the s
123. ormally selected OFF P88E 6E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Closing Reports sent on Arming RELATED OPTIONS P88E 1E AREA1 Open Close reports P88E 2E AREA2 Open Close reports P88E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Manual Exclude Reports enabled RELATED OPTIONS P88E 8E Auto Exclude Reports P88E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Auto Exclude Reports enabled RELATED OPTIONS P88E 7E Manual Exclude Reports PROGRAMMING FORCED OPENING REPORT If Forced Opening Report is selected ON when an alarm has been reset by a valid User Code or Radio Key the dialler will send an Opening report along with a restoral report for the zone or miscellaneous input which caused the alarm PROGRAMMING SEQUENCE P88E 5E toggles the option ON and OFF OFF No Forced opening Reports ON Forced opening Reports enabled DELAY CLOSING REPORT If selected ON Closing reports if enabled are sent at the end of Exit Time Normally Closing reports are sent immediately on arming PROGRAMMING SEQUENCE P88E 6E toggles the option ON and OFF OFF Closing Reports sent on Arming ON Closing Reports sent at end of Exit Time MANUAL EXCLUDE REPORT Enables Manual Exclude Reports for zones Exclude Reports for 24hr zones are sent on exiting EXCLUDE mode PROGRAMMING SEQUENCE P88E toggles the option ON and OFF OFF N
124. ote by PC FACTORY DEFAULT OFF No Remote Status Reporting P90E 7E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Remote Event Reporting 9 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Callback RELATED OPTIONS P90E 1E Enable Upload Download P81E Telephone Number 4 Callback PROGRAMMING REMOTE DISARMING Allows the remote Disarming of the control panel using a standard DTMF telephone or mobile phone from anywhere in the world PROGRAMMING SEQUENCE P90E 4E toggles the option ON and OFF OFF No Remote Disarming ON Remote Disarming enabled REMOTE AUX CONTROL Enables the remote turn ON OFF of the AUX1 2 3 and 4 outputs using a standard DTMF telephone or mobile phone from anywhere in the world PROGRAMMING SEQUENCE P90E 5E toggles the option ON and OFF OFF No Remote AUX control ON Remote AUX control enabled REMOTE STATUS REPORTING Enables Remote Status Reporting PROGRAMMING SEQUENCE P90E 6E toggles the option ON and OFF OFF No Remote Status Reporting ON Remote Status Reporting enabled REMOTE EVENT REPORTING Enables Remote Event Reporting PROGRAMMING SEQUENCE P90E 7E toggles the option ON and OFF OFF No Remote Status Reporting ON Remote Status Reporting enabled CALLBACK MODE Enables two methods of connecting by computer for remote upload download NO CALLBACK Allows remote access by computer as long as the panel s A
125. pt This can be used as Fail To Communicate output to trigger backup communications devices such as GSM The AUX4 output is automatically turned off on the next successful communication attempt or when the panel is next disarmed 5E OFF 4 is not a FAIL TO COMMUNICATE output Factory default 5E ON Aux4 is a FAIL TO COMMUNICATE output ENABLE TELEPHONE REMOTE CONTROL OF AUX4 Enables Aux4 output to be controlled by telephone remote control PSOE 5E must also be enabled After establishing telephone control of the panel use telephone key 6 to toggle the output on and off OFF Aux4 cannot be controlled by telephone Factory default 6E ON Aux4 can be controlled by telephone READER OUTPUT TO AUX4 This option enables an access control reader to pulse Aux4 when a valid access card is presented Set the reader using P318E P328E or P338E 8E OFF No reader output to Aux4 Factory default 8E ON Reader output to Aux4 ZONES 1 8 D8 amp D16 ZONES 9 16 D16 Option No Description 123 4 5 6 7 849 10 11 12 13 14 15 16 P125E ENABLE HARDWIRED ZONES ON ON ON ON ON ON ON ONJON ON ON ON ON ON ON ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All on NOTES THIS OPTION APPLIES ONLY TO WIRED ZONES AND HAS NO EFFECT ON RADIO ZONES NESS RADIO NOTES Signal strength of Radio Keys can be tested in USER PROGRAM Mode or INSTALLER PROGRAM
126. r 890 007 For products 106 000 D8x Control Panel with LED keypad 106 001 D8x Control Panel with LCD keypad 106 004 D16x Control Panel with LCD keypad COPYRIGHT NOTICE All rights reserved No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Ness Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2005 Ness Security Products Pty Ltd ABN 28 069 984 372 INSTALLATION Product features nete iet 4 Specifications and 5 Installation 6 Inputs and 7 CONNECTION 8 9 Keypad eire toner Rer 10 OPERATION Operation Summary 11 HOW TO PROGRAM Quick start Programming sse 12 How to enter Program Mode 13 GENERAL OPTIONS User CodeS uim Bt 14 15 TIME S n ees A heed 16 Vibration Sensitivity eee 17 Zone ASIA ME wi 18 19 Definitions Day Zones Temp Day
127. r the zone disarmed EXCLUDE CODE E number s to be excluded care User then press E to exit Exclude mode The Exclude light flashes constantly while zones are excluded Excluded zones are automatically Included next time the panel is disarmed f a user code is assigned to a radio key and has Extra Option 4E enabled Cope armine then pressing OFF toggles the panel arm disarm state TEMPORARY DAY ZONE 02 operation While remaining in normal operating mode the user can add and remove Temporary Day Zones and enable disable day zone operation The panel must initially be Press P E To enter TDZ Selection Mode disarmed then press Zone No E select one or more zone to be Temporary Day Zones P64E 2E must be on to enable the use of then press E To save changes and exit TDZ Selection Mode Temporary Day Zones Press 0 E To enable disable TDZ operation Note The keypad does not indicate if TDZ is enabled or disabled See page 20 for more information on Temporary Day Zones INSTALLATION RECORD DATE PURCHASED DATE INSTALLED INSTALLATION COMPANY D e D 16 TELEPHONE MONITORING COMPANY NESS D8 ALARM CONTROL PANEL TELEPHONE Ness D16 ALARM CONTROL PANEL P26E ENTRY DELAY TIME 1 Seconds ZONE ASSIGNMENT 2 P27E ENTRY DELAY TIME 2 Seconds gt gt gt A 25 lt 155 Lf E P28E EXIT DELAY TIME Seconds m
128. remote access PROGRAMMING SEQUENCE P90E 1E toggles the option ON and OFF OFF No Remote Access ON Remote Access enabled ENABLE FIRST CALL MODE For remote access the panel can answer incoming telephone calls on either the First or Second Call First Call Mode The panel answers a telephone call after the number of Rings set by P91E Used if the panel has the telephone line exclusively or distinctive telephone ring signal is being used Second Call Mode The panel answers on the second telephone call The first telephone call must ring for at least the number of rings set by P91E The second call to the panel must be made after a wait of between 10 and 50 seconds Second Call mode is used to stop other equipment such as fax machines from answering the call PROGRAMMING SEQUENCE P90E 2E toggles the option ON and OFF OFF Second Call Mode enabled ON First Call Mode enabled REMOTE ARMING Allows the remote Arming of the control panel using a standard DTMF telephone or mobile phone from anywhere in the world PROGRAMMING SEQUENCE 9 toggles the option ON and OFF OFF No Remote Arming ON Remote Arming enabled Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL P90E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Remote Disarming PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Remote AUX control 9 6E PROGRAM MODE LEVEL Installer Rem
129. requency Report Misc Restorals Double Key Keypad Panic Report Multiple Zone alarms Keypad FireAlarm Account No 2 zones Keypad Medical Alarm Tel No 3 for Test Calls Supervised zones NONE Tel No 4 Callback Zone Supervision alarm to RESET OFF P82E 1E Send RESTORAL report immediately Zone Supervision alarm to STROBE OFF 2 Send RESTORAL after siren time Zone Supervision alarm to SONALERT OFF SE Send RESTORAL after Disarm amp seal 4E Send RESTORAL after Disarm always Zone Supervision alarm to SIREN OFF Enable WIRED ZONE supervision OFF TEST CALL Interval E dong not used OFF Time before FIRST TEST CALL 6 12hrs Zone Supervision speedup x 6 OFF P85E 1E Auto Dialling Pulse amp DTMF 2 DTMF Dialling Decadic always DTMF Dialling always P86E 1E Disable Dialler 2 CONTACT ID FORMAT Audible DTMF format Audible PULSE Format Contact ID Audible DTMF 6E Contact ID Audible PULSE P87E 1E Split dial Primary Secondary numbers 2E Check for Dial Tone not used 4E 4 Dialling attempts P88bE 1 Send AREA 1 OPEN CLOSE REPORTS 2E Send AREA 2 Open Close reports Siren Chirp on Kiss off 4E Flash Strobe on Kiss off Forced Opening report Zone Supervision speedup x10 OFF Zone Supervision Time 24 hours Enable
130. rms do not turn on Aux2 Factory default 2E ON Zone Supervision Alarms turn on Aux2 RADIO KEY AUX BUTTON TOGGLE When this option is on Radio Key s AUX button will TOGGLE the Aux2 output The Aux2 output will operate independently of the panel s armed status ie disarming does not turn Aux2 off 3E OFF Zone Supervision Alarms do not turn on Aux2 Factory default 3E ON Zone Supervision Alarms turn on Aux2 RADIO KEY AUX BUTTON PULSE When this option is on Radio Key s AUX button button will PULSE on for 2 sec the Aux2 output 4E OFF Radio Key AUX button does not Pulse Aux2 Factory default 4E ON Radio Key AUX button Pulses Aux2 TELEPHONE LINE FAULT TO AUX2 When this option is enabled a telephone line fault condition will turn on the Aux2 output Aux 2 will turn off when the telephone line is restored 5E OFF No telephone line fault to Aux2 Factory default 5E ON Telephone line fault to Aux2 ENABLE TELEPHONE REMOTE CONTROL OF AUX2 Enables Aux2 output to be controlled by telephone remote control 9 5E must also be enabled After establishing telephone control of the panel use telephone key 4 to toggle the output on and off 6E OFF Aux2 cannot be controlled by telephone Factory default 6E ON Aux2 can be controlled by telephone DOOR OPEN TOO LONG DOTL ALERTS TO AUX2 This option enables DOTL zones P303E to turn on Aux2 when the DOTL Time P304E expires TE OFF DOTL alert does not turn
131. rogrammed to be Radio Codes or Access Cards as required NOTES 1 Keypad Codes beginning with 0 zero can be programmed but they will not operate the panel This is an alternative method for disabling user codes The MEMORY E function is recommended for deleting user codes eee 2 All codes must be unique to each other Codes are rejected if already used Some codes that are similar to existing codes may also be rejected PROGRAMMING KEYPAD CODES Press P 201 256 E The existing code is displayed one digit at a time Press NEW CODE E NEW CODE AGAIN E The new code is displayed Example To program the Master Code to be 1234 Press P201E 1234E beep 1234E beeps When re programming a Keypad Code the old code does not need to be deleted first The new code will overwrite the old code DELETING KEYPAD CODES To delete a User Code without programming a new code press the MEMORY key in place of the code Example To delete User Code 2 press P202bE MEMORY E A keypad code only needs to be deleted if you re not replacing it with a new code ARM ONLY CODES Arm Only is an extra option for user codes See next page for further information User Codes 2 56 can optionally be programmed as Arm Only Codes which can Arm but cannot Disarm the panel Used for cleaners temporary staff etc Example To program User Code 2 to be 1234 and an Arm Only code Press P202E EXCLUDE E 3E EXCLUDE E 1234E 1234E EXCLU
132. s D8x D16x ConTROL PANEL INSTALLATION MANUAL NESS LED KEYPAD 100 192 NESS D816 LCD KEYPAD 100 667 D8 PANEL ONLY D8 OR D16 PANEL 105mm 4 90mm 4 LED KEYPAD T LCD KEYPAD Backlit LCD H1 2 3 4567 8 icon display 9 10 11 12 13 14 15 16 Armed vf amp mM Sanka lodi ame dub Exclude oL E SA WON OA BATTERY MANS EXCLUDE PROGRAM UNE Not Ready light PANIC buttons MEMORY button ARM button PANIC buttons ARM button AW Maca MONITOR button MONITOR button C42 C EXCLUDE button EXCLUDE button MEMORY button PROGRAM button j COD PROGRAM button ENTER button ENTER button Protective flap not shown Protective flap not shown The Not Ready light is on when the panel is not ready to Arm i e a zone is unsealed there may still be movement in the premises or door or window left open KEYPAD ICON KEYPAD ICON STATUS DISPLAY OC FLASHING ZONES 1 16 Zone is sealed Zone is unsealed Zone alarm Zone is unsealed or Power fault or System is Armed READY or phone line fault a Monitor Mode 1 ARMED Disarmed Armed AREA 1 LED Keypad only ARM2 Disarmed A Disarmed di MAINS Normal BATTERY Normal Ready to Arm Armed AREA 2 Monitor Mode Mai
133. s assigned to Reader2 P301E 7E enables Zone 7 to trigger the AUX outputs assigned to Reader3 PROGRAMMING SEQUENCE P301E 5E 6E or 7E toggles the option ON and OFF OFF The zone is a normal alarm zone ON The zone is a REX input Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL EP Niess Bax D16x Conso Pah WSTALION Mawa 0000000000 P301E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON THIS OPTION IS AVAILABLE IN D8X D16X V5 3 AND LATER ACCESS CONTROL STROBE FLASH ON ARM DISARM BY READER This option enables strobe flash when arming and disarming by Reader D8x D16x versions prior to V5 4 had strobe flash permanently enabled PROGRAMMING SEQUENCE P301E 8E toggles the option ON and OFF OFF Strobe flash disabled ON Strobe flash enabled ZONES 1 8 D8 amp D16 ZONES 9 16 D16 Option No Description 123 4 5 6 7 849 10 11 12 13 14 15 16 P303E DOTLZONES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All OFF No DOTL zones NOTES Zones can be assigned as DOTL zones in addition to normal alarm functions Therefore DOTL zones can operate as alarm zones when armed and DOTL zones when disarmed Day Zone programming still applies PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 20 seconds PROGRAM MODE LEVEL Installer Remote by PC RELATED OPTIONS P121E 7E DOTL Alerts to Aux1 P122
134. s enabled all 16 zones wire into physical inputs 1 8 using 2K2 and 4K7 resistors and physical zone inputs are 9 16 are no longer used New Aux output functions Aux1 2 3 and 4 can be individually programmed to perform one of many functions such as zone alarm output zone supervision alarm output radio key output pulse or toggle telephone remote control and access control output New SERIAL port for connection to future accessories Fast up download from PC by direct connect to the panel s serial port In Installer Program mode Option to allow the panel to answer incoming phone calls in either First Call or Second Call modes New access control features including a Reader input for connection of up to 3 access control proximity Weigand readers Part No 106 015 Each access control reader s output can be programmed to any Aux output for powering of electric door locks and other accessories Zones 5 6 amp 7 can be converted into Request To Exit REX inputs for access control purposes Up to 55 user codes can be programmed as access codes to allow arming and disarming using proximity access cards or fobs New LISTEN pins on the main board allows the installer to listen in to dialler tones for diagnostic purposes Dialler Listen in via the Siren output is also available New main board design using a faster new microprocessor with Flash Memory and enhanced RAM and EEPROM capacity New Nesscomms soft
135. s in front of a user code when disarming the user to send a silent This sequence will disarm the panel and send a Duress report by duress report while dialler to the central station disarming if the system is being monitored by a Report KevPAp Duress must be enabled P75E 1E central station EXCLUDE ZONES Press E EXCLUDE E can only If the ExcLubE Suonrcur is enabled P62E 2E b d when th li warmed then Zone No E Zone No Enter the zone disarmed EXCLUDE CODE E number s to be excluded ENSE oh UA then press to exit Exclude mode The Exclude light flashes constantly while zones are excluded Excluded zones are automatically Included next time the panel is disarmed f a user code is assigned to a radio key and has Extra Option 4E enabled Cope armine then pressing OFF toggles the panel arm disarm state TEMPORARY DAY ZONE TDZ operation While remaining in normal operating mode the user can add and remove Temporary Day Zones and enable disable day zone operation The panel must initially be Press P E To enter TDZ Selection Mode disarmed then press Zone No E To select one or more zone to be Temporary Day Zones P64E 2E must be on to enable the use of then press E To save changes and exit TDZ Selection Mode Temporary Day Zones Press 0 E To enable disable TDZ operation Note The keypad does not indicate if TDZ is enabled or disab
136. se station monitored If Open Close reports are enabled RELATED OPTIONS P101E P116E Programming Radio Devices TO DELETE A RADIO CODE Any Radio Code can be deleted if necessary lost radio key or if programming a radio key over an old one And a Radio Code is automatically deleted when the user code type is changed to keypad code or reader code EXAMPLE To delete Radio Code 56 In Installer Program Mode Press P256E OE Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL F3 PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC NOTES These options are dynamically updated When the program option is entered the keypad display will show the current value Option No Description Default Note P130E REAL TIME CLOCK SET MINUTES 00 00 59 minutes P131E REAL TIME CLOCK SET HOURS 00 00 23 hours 00 midnight P132E REAL TIME CLOCK SET DAY 01 01 31 days P133E REAL TIME CLOCK SET MONTH 01 01 12 months P134E REAL TIME CLOCK SET YEAR 04 00 63 2000 2063 P135E REAL TIME CLOCK SET DAY OF WEEK 1 1 7 1 Sunday 7 Saturday REAL TIME CLOCK PROGRAMMING P130E Real Time Clock MINUTES Enter a value between 00 and 59 Default 00 minutes P131E Real Time Clock HOURS Enter a value between 00 and 23 Default 00 hours P132E Real Time Clock DAY OF THE MONTH Enter a value between 01 and 31 Default 01 1st day of the month Ensure that the setting does not exceed the days in the curren
137. sient burst Surge Immunity Conducted RF Immunity Voltage Dips and Interruptions Mains Supply Variations AS NZ CISPR 22 2002 Class B Electromagnetic Radiation Terminal Disturbance Voltage EN61000 6 3 2001 Harmonic Current Emissions Voltage fluctuations and Flicker TELECOM TBR21 EU PTC200 NEW ZEALAND TELECOM AS ACIF S002 AUSTRALIA SAFETY EN60950 2000 inc Country Deviations Safety of Information Technology Equipment AS NZ3260 1993 incl AMDTS 1 2 3 84 T8001 1997 ACA Australian Communications Authority N55 A Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL BH INSTALLATION WARNING THIS EQUIPMENT MUST ONLY BE INSTALLED AND MAINTAINED BY SERVICE PERSONNEL ESD WARNING Electrostatic Discharge Once properly installed Ness control panels are well protected from ESD However take note of the following precautions during installation The human body can generate static electricity when it is insulated from earth for instance by walking over carpet ESD occurs and a small shock is sometimes felt if an earthed metal object is then touched The installer should be aware that if he generates static electricity while installing the panel and then discharges this static electricity into the internal components on the main D8 D16 circuit board or the keypad board then ESD damage may occur The circuit board should not be unwrapped until it is actually ready to be installed Methods to av
138. software version Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL These options allow selective restoring of various factory defaults For example you can default clear all the User Codes without affecting any other programmed options PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT not applicable NOTES P98E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT User Code 1 123 All other codes blank NOTES This option DOES NOT clear the Installer Code PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 000000 PROGRAMMING Option No Description P95E CLEAR RADIO DEVICES P96E CLEAR MEMORY P97E CLEAR PANEL OPTIONS RESTORE FACTORY DEFAULTS P98E CLEAR USER CODES P99E PROGRAM INSTALLER CODE CLEAR RADIO DEVICES This option clears all Radio Devices assigned to zones 1 8 or 1 16 This option does not clear User Codes PROGRAMMING SEQUENCE P95E Clears Radio Device Codes CLEAR MEMORY Enter P96E when in Installer Program mode to clear all events in the Alarm memory display PROGRAMMING SEQUENCE P96E Clears Alarm Memory display CLEAR PANEL OPTIONS This option restores panel program options to their factory default values Defaults the options POOE P26E
139. ssss 18 030 Keyswitch Panic ssss 18 031 Keypad Panic ssss 18 Radio Key Panic ssss 18 Medical Alarm ssss 18 Fire ssss 18 Exit Install mode ssss 18 External Tamper ssss 18 Internal Tamper ssss 18 Q q 1 1 1 1 1 1 1 q q Keypad Tamper ssss18 q q q q q q 1 1 3 1 q q Radio Sensor Supervision ssss 18 Radio Sensor Tamper ssss 18 Radio Sensor Low Battery 5555 18 Mains Fail ssss 18 Panel Battery Fail ssss 18 Open ssss 18 Force Open Cancel ssss 18 Odd Close ssss 18 Odd Test Report ssss 18 063 001 016 001 016 Zone 1 16 Manual Exclude ssss 18 Zone 1 16 Auto Exclude ssss 18 Keyswitch arming is identified as User 57 Shortcut arming is identified as User 58 m Ness D8x D16x Control PANEL INSTALLATION MANUAL P87E 1E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Alternate Dial RELATED OPTIONS P87E 4E Number of Dialling attempts P87E 2E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON Dial only with dial tone P87E 4E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON 4 dialling attempts NOTES Sets the total number of dialling attempts E g If 4 dialling attempts is selected this means 2 attempts per telephone number RELATED OPTIONS P87E 1E Alternate dialling PROGRAMMING e c Io 2
140. stralia and New Zealand OFF Clock uses mains frequency timing PROGRAMMING SEQUENCE P89E 7E toggles the option ON and OFF OFF Clock uses mains frequency timing ON Clock uses internal timing Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Remote Access RELATED OPTIONS P91E Required Rings PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Second Call Mode enabled NOTES If Callback is enabled P9OE 8E is on then First Call mode is disabled RELATED OPTIONS P91E Required Rings PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Remote Arming NOTES Remote Access must also be enabled RELATED OPTIONS P90E 1E Enable Upload Download See page 71 for details on Remote Operation by telephone NE z RS olg o t SE eu es Wee EAE Equus x tt s Online 5 15121215 lels 8 Ela lelelelelele c oO we um eq we ge we pe Option No Description 1E 2E 3E 4E 5E 6E 7E 8E P90E UPLOAD DOWNLOAD OPTIONS REMOTE ACCESS When selected On this option allows the panel to be remotely upload downloaded by a remote computer or controlled by a remote telephone When the option is Off the panel will not answer incoming telephone calls preventing any type of
141. t a different zone type in the DELAY GROUP Entry Delay as a reminder to disarm the panel Entry beeps can be disabled by program option P60E 1E When a zone is selected for this type it is automatically deselected from any other zone type in the DELAY GROUP n Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 2E ON Zone 2 is a Handover zone NOTES When a zone is selected for this type it is automatically deselected from any other zone type in the DELAY GROUP PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All OFF No zones have Entry Delay2 NOTES PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT ON All zones are Lockout zones NOTES The SIREN output always locks out OE will turn all selections OFF MEMORY E will turn all selections ON RELATED OPTIONS P60E 4E Tamper Reset Lockout P78E Multiple alarm reports AREA PARTITIONING PROGRAMMING HANDOVER ZONES Handover zones are delayed only if entry is made through an Entry Delay zone first If a Handover zone is triggered first the zone behaves as an instant zone Normally the point of entry zone should be Delay zone with any other zones in the entry path programmed as Handover zones PROGRAMMING SEQUENCE P42E Zone turns the options ON P42E Zone ON The zone is a Handover zone To deselect the option select a different zo
142. t month The panel does not cross check this setting P133E Real Time Clock MONTH Enter a value between 01 and 12 Default 01 January P134E Real Time Clock YEAR Enter a value between 00 and 63 2000 2063 Default 04 2004 P135E Real Time Clock DAY OF THE WEEK Enter a value between 1 and 7 1 Sunday Default 1 Sunday PROGRAMMING SEQUENCE P130E P135 existing value is displayed one digit at a time ENTER NEW VALUE E new value is displayed one digit at a time E Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAM MODE LEVEL Installer If connecting multiple readers the option to enable multiple readers P301E 1E should be turned on before programming any access cards Enabling P301E 1E erases existing card programming If P301E is enabled momentary push button can be wired to zone 8 as shown For example this option allows the reader output to operate a door lock during the day by presenting your card Then at the end of the day press the push button within 5 seconds of presenting the card and the panel will arm NORMALLY OPEN Zone 8 Input Momentary pushbutton 28 NS A NORMALLY CLOSED Zone 8 Input Momentary pushbutton 78 c 2K2 ACCESS CONTROL Option No Description P300E DEFAULT ALL ACCESS CONTROL OPTIONS DEFAULT ALL ACCESS CONTROL OPTIONS Enter P300E in Installer program mode to return all access control programs to factory defa
143. th the Internal Tamper Lead supplied PROG TAMP serves as the 24hr tamper input for the panel s internal tamper switch Replace the PROG Link with the Box Tamper Lead Connect the Internal Tamper Lead spade terminals directly to the terminals of the internal tamper switch supplied An end of line resistor is NOT required on this input When PROG TAMP is used for Internal Tamper powering up with the panel s cover open will enter Installer Program Mode OUTPUTS 12 VOLT OUTPUT A regulated 13 8 VDC output is available to power detectors and other equipment This output is available from two sets of terminals marked 12V and OV This output is protected by Automatic Reset fuse A maximum load of 500mA may be connected to these terminals SIREN The on board siren driver will drive a maximum of 3 x 8 ohm horn speakers Ness Part No NOI110 or 100 171 Internal Siren The output will reset at the end of siren time P29E or whenever the panel is reset whichever comes first This output is protected by an Automatic Reset fuse STR A latched 12VDC output for connecting strobe lights This output will reset after 72 hours 3 days or when the panel is disarmed D8 D16 versions prior to V4 5 allow indefinite strobe operation until the panel is reset A maximum of 2 x 1 Watt Strobes Ness Part No NOI300 can be connected to this output This output is protected by an Automatic Reset fuse RESET A 12V DC output for con
144. the option number for the user code which will be become a radio code P202E P256E Press EXCLUDE E to enter Extra Options mode The Exclude light is on Press 5E to enable that user code as a Radio Code Light 5 is on Press EXCLUDE E to exit Extra Options mode The Exclude light is off Press 1 The READY light will turn ON to indicate that the User Code is ready to accept the Radio Key If a code is already programmed the READY light will not turn on and a warning beep will sound To clear the code press OE then go back to step 5 OE clears any existing codes Press the OFF button on the Radio Key to be programmed If the Radio Key is accepted the READY light will turn off and 3 beeps will sound If the READY light stays on and a warning beep sounds the Radio Key is already assigned to another User Code and must be cleared from that User Code first EXAMPLE To enable User Code 56 as a Radio Code and program a Radio Key In Installer Program Mode Press P256E EXCLUDE E 5E EXCLUDE E 1E then press the OFF button on the Radio Key 201 P256E PROGRAM MODE LEVEL Installer FACTORY DEFAULT No Radio Codes all code are keypad codes NOTES User Code 1 Master Code is always a Keypad Code Radio Codes can be deleted by keypad in the case of a lost Radio Key Radio Keys are assigned to User Codes so that Open Close reports are identified by user number when the control panel is ba
145. to Green 101 014 Ultraprox Weigand Reader Blu Grn Connect to READER header on the panel main board 101 014 Ultraprox Weigand Reader Violet For READER 2 connect Violet to White 101 014 Ultraprox Weigand Reader Violet For READER 3 connect Violet to Black Optional Reader Interface board Part No 106 012 If using multiple Weigand readers they must be either ALL addressable or ALL non addressable That is use either three Ness 101 014 addressable Weigand readers or three generic Weigand readers Codes selected for Code Only Arming can be used as REX codes for access control functions That is the code can operate an output instead of arming disarming the panel There are two conditions needed to make the code operate as a REX code It is assigned to CODE ONLY ARM and it is not assigned to either Area 1 or Area 2 The first digit of the user code determines which AUX output is operated by the REX code That is a REX code in the format 1xxx operates AUX1 2xxx operates AUX2 and 3xxx operates AUX3 Notes 1 Reader 1 can also use codes starting with 4 9 if only one exit point is used 2 Set P318E P328E P338E options to select appropriate AUX outputs 3 Set corresponding P121E P122E P123E P124E options to 8E Setup Example User Codes 1555 2555 3555 are programmed to be Code Only Arm and are not assigned to Ar
146. to Zone 8 are on the 1st Expander The AUX ARM and other outputs are on the first Expander Zones 9 to Zone 16 are on the 2nd Expander Use this option when a variety of outputs are needed using only one Expander PROGRAMMING SEQUENCE P117E 2E toggles the option ON and OFF OFF No Alternate Format ON Alternate Format enabled Alternate format disabled Alternate format enabled P117E 2E OFF P117E 2E ON OUTPUT EXPANDER 1 EXPANDER 2 OUTPUT EXPANDER 1 EXPANDER 2 Or if only using Or if only using one expander one expander 1 Zone 1 User Code 9 1 Zone 1 User Code 9 2 Zone 2 User Code 10 2 Zone 2 User Code 10 3 Zone 3 User Code 11 3 Zone 3 User Code 11 4 Zone 4 User Code 12 4 Zone 4 User Code 12 5 Zone 5 User Code 13 5 Zone 5 User Code 13 6 Zone 6 User Code 14 6 Zone 6 User Code 14 7 Zone 7 User Code 15 7 Zone 7 User Code 15 8 Zone 8 Tel Line Fail 8 Zone 8 Tel Line Fail 9 Zone 9 Aux 3 9 Arm Area 1 Zone 9 10 Zone 10 Aux 4 10 Arm Area 2 Zone 10 11 Zone 11 Aux 1 11 Aux 1 Zone 11 12 Zone 12 Aux 2 12 Aux 2 Zone 12 13 Zone 13 Arm Monitor 13 Arm Monitor Zone 13 14 Zone 14 Mains Fail 14 Mains Fail Zone 14 15 Zone 15 Battery Fail 15 Battery Fail Zone 15 16 Zone 16 Ext Tamper 16 Ext Tamper Zone 16 P117E 3E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF No Day Zone Follower NOTES Day zone outputs are turned off when the D16 is in Monitor
147. tween 1 and 99 This is automatically multiplied by 2 Test Calls must be enabled by option P89E 1E PROGRAMMING SEQUENCE Press P83E The existing Test Call Interval time will be displayed Press NEW TIME E The new Test Call Interval time will be displayed EXAMPLE To program daily test calls Press P83E12E TIME BEFORE FIRST TEST CALL This option sets the time before the first Test Call and is used to set the preferred time for Test Calls Programmable from 2 to 198 Hours Enter a value between 1 and 99 This is automatically multiplied by 2 EXAMPLES A New Installation Set the time before the first test call E g If you are programming the panel at 5pm and you want test calls to be sent at 1am Enter P84E 4E 4 x 2 8hrs Therefore 5pm 8hrs 1am B Existing Installation To reset the time that test calls are sent E g Our example panel is sending test calls at 1am and you want to change it to 2am If you are programming the panel at 6pm enter P84E 4E 4 x 2 8hrs Therefore 8hrs 2am PROGRAMMING SEQUENCE Press P84E The existing Time Before First Test Call will be displayed See note 3 Press NEW TIME E The new Time Before First Test Call will be displayed L a S 1212 S os amp APA pss 2 2 6 Option No Description 1E 2E 3E 4E 5E 6E 7E 8E P85E DIALLING METHOD ON DIALLING METHOD The dialler can be
148. ult values PROGRAMMING ACCESS CARDS If the panel has 1 2 or 3 Weigand proximity readers connected up to 55 of the panel s user codes can be programmed as Reader Codes This allows arming disarming by access card and operation of AUX outputs to open electric door strikes Use the Extra Options programming mode to enable selected user codes to Readers 1 2 or 3 When a user code is enabled as a Reader Code its Keypad Code if any is automatically deleted A user code enabled as a Reader Code cannot also be a Keypad Code or Radio Code PROGRAMMING SEQUENCE In Installer Program Mode enter the option number for the user code to be programmed 202 256 Press EXCLUDE E to enter Extra Options mode Exclude light turns on Press 6E 7E or 8E to assign the user code to Reader 1 2 or 3 Keypad light 6 7 or 8 will turn on Press EXCLUDE E to exit Extra Options mode Exclude light turns off Q Press 1E The keypad READY light will turn ON to indicate that the user code is ready to accept an access card If a code is already programmed the READY light will not turn on and a warning beep will sound To clear the code press OE then go back to step 5 OE clears any existing codes Q Present a valid access card to the reader If the access card is of the correct type the reader s orange light will turn on If the access card is accepted the keypad READY light will turn off and 3 beeps will sound If the READY lig
149. using lid Remove the battery from the base Securely mount the rear panel housing to a secure location Run all cabling needed for the installation Before removing the circuit board from its protective wrapping Insert the PCB stand offs in the panel and then plug the circuit board onto the stand offs 7 Wire to the circuit board terminal blocks as per the wiring instructions shown in this installation manual 8 Replace the battery 9 Insert the panel tamper bracket as shown below 10 Close the lid and program the panel as required o gp omr NESS EB04 ENHANCED HOUSING Removable lid Clip this side first then secure the lid with screws provided Backup battery holder Fits up to 12V 7Ah battery Secure and easy to fit standoffs for the main board Tamper switch on Provision for Rear cable entry for lid protects lid and slide in accessory cavity walls Top amp box rear boards bottom knock outs for conduit entry Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL INPUTS MONITORED ZONES The Ness D8 D16 has multiple monitored inputs 8 or 16 fully programmable zone inputs Monitored by end of line resistor 1 x 24 hour External TAMP input Monitored by end of line resistor 1 x 24 hour Box Tamper input Normally Closed input Resistor is not required ZONE INPUTS Each zone input must be terminated with a 2K2 2200 ohm resistor or 2K2 and 4K
150. ut 2 2 KP Panic to SIREN output P61E TAMPER amp PANIC ALARM MAPPING 2 TAMPER ALARM OUTPUT MAPPING This option selects which outputs will trigger when a Tamper Alarm occurs PROGRAMMING SEQUENCE P61E 1E 4E 1000 65 the options ON and OFF 1E ON Tamper Alarm to Reset output 2E ON Tamper Alarm to Strobe output 3E ON Tamper Alarm to Keypad Sonalert output 4E ON Tamper Alarm to Siren output KEYPAD PANIC ALARM OUTPUT MAPPING This option selects which outputs will trigger when a Keypad Panic alarm occurs PROGRAMMING SEQUENCE P61E 5E 8E oggles the options ON and OFF 5E ON Keypad Panic Alarm to Reset output 6E ON Keypad Panic Alarm to Strobe output TE ON Keypad Panic Alarm to Keypad Sonalert output 8E ON Keypad Panic Alarm to Siren output Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 1E ON Memory Display shortcut enabled 2E ON Zone Exclude shortcut enabled 3E ON Monitor Mode shortcut enabled 4E OFF Keypad Panic disabled ON 1 Arming shortcut enabled 6E OFF Area2 Arming shortcut disabled NOTES A Tamper Alarm can be caused by the TAMP input or the J1 link Allocate a User Code to Area2 before programming Area2 shortcut arming If Area 2 is shortcut armed then it will always remain armed This will bar entry into program mode until Area 2
151. utput m Supervision alarms to STROBE output ae Supervision alarms to SONALERT output A Supervision alarms to SIREN output m Supervision speedup x6 2 Supervision speedup x10 Option No Description 5E 6E P66E ZONE SUPERVISION ALERTS ZONE SUPERVISION ALERTS RESET OUTPUT Setting this option turns the Reset output ON when a SUPERVISED ZONE alert occurs The Reset output will remain ON for the duration of the ALARM TIME Set by Option P29E PROGRAMMING SEQUENCE P66E 1E toggles the option ON and OFF OFF Supervision Reset output disabled ON Supervision Reset output enabled ZONE SUPERVISION ALERTS STROBE OUTPUT Setting this option turns the Strobe output ON when a SUPERVISED ZONE alert occurs The Strobe output will remain ON until the panel is disarmed PROGRAMMING SEQUENCE P66E 2E toggles the option ON and OFF OFF Supervision Strobe output disabled ON Supervision Strobe output enabled ZONE SUPERVISION ALERTS KEYPAD SONALERT Setting this option turns the Keypad Sonalert ON when a SUPERVISED ZONE alert occurs The Keypad Sonalert remains ON until any keypad key is pressed Also turning this option ON makes all Supervision outputs delayed by one minute PROGRAMMING SEQUENCE P66E toggles the option ON and OFF OFF Supervision Keypad Sonalert disabled and all Supervision outputs trigger instantly ON Supervision Keypad Sonalert enabled and all Supervision outputs are
152. utput when 1 armed P124E 1E AUX4 output when Area2 armed PROGRAMMING TAMPER SIREN LOCKOUT This option programs the Tamper input to Lockout i e cause the Siren amp Reset outputs to sound only once whilst the panel is armed PROGRAMMING SEQUENCE P60E toggles the option ON and OFF OFF Tamper Reset Lockout disabled ON Tamper Reset Lockout enabled DURESS TO RESET OUTPUT Keypad Duress is normally a silent alarm This option makes the Duress alarm trigger the Reset output To Disarm with Duress add any of the digits 5 6 8 or 9 in front of the user code when Disarming PROGRAMMING SEQUENCE P60E 5E toggles the option ON and OFF OFF No Reset output on Duress alarm ON Duress alarm triggers Reset output AUTO EXCLUDE ZONES If a zone is unsealed at the end of Exit Time the panel can either Exclude ignore that zone or immediately alarm The panel will give a 2 second Siren burst at the end of Exit Time to indicate that the panel is armed with a zone s Auto Excluded The 2 sec Siren burst can be disabled by option 62 7E PROGRAMMING SEQUENCE P60E GE toggles the option ON and OFF OFF Auto Exclude disabled instant alarm if unsealed at end of Exit Time ON Auto Exclude enabled zone is excluded if unsealed at end of Exit Time DISABLE THE DISPLAY The LED indicators on the keypad can be programmed to blank after 4 minutes of no keypad use Any action that causes a beep will restore the display
153. uts Plugs into the J5 AUX header on the main board One non addressable Weigand reader can be plugged directly into the READER header on the panel main board The Output Expander provides 16 programmable open collector outputs Plugs into the J5 AUX header on the main board See page 54 55 16 15 14 13 12 11 10 9 87 6 5 4 8 2 1 12VIn Up to 3 addressable Weigand readers Ness 101 014 can connect via the optional 3 way Reader Interface FULL CONNECTION DIAGRAM ON PAGE 69 The Relay Board and the Output Expander Board connect to the J5 header on the D8 D16 main board but you cannot 2004 Ness Security Products connect both at the same time If required the Relay Board can be driven by outputs from the Output Expander H Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL INEZ Security Products ED D16 MAIN BOARD TELEPHONE LISTEN PINS D 16 DIALLER SECURITY ALARM PANEL Diagnostics Connect 8 Ohm horn speaker to N listen to dialler tones ZONES 9 16 amp GR rc a OTs N m J1 PROG TAMP LINK FA Connect internal tamper G5 5 E RECEIVER lead or leave linked with z m Header tor the supplied jumper FA m Siora Pad Power up with the link m insi off to enter Installer ji Program Mode o AUX1 DE AUK Aux outputs dra AUX4 1 4 S 12V D t SERIAL E 3 Conne
154. vision alarm The SUPERVISION TIME setting is from 01 to 24 hours For timing up to 24 minutes set P66E 7E 7 8E on For timing up to 24 hours set P66E 7E 7 8E off PROGRAMMING SEQUENCE P67E existing time is displayed one digit at a time ENTER NEW TIME E new time is displayed one digit at a time EXAMPLE To program SUPERVISION TIME to 4 hours P67E 04E RADIO SUPERVISION OPERATION The purpose of Radio Supervision is to verify the correct operation of Ness Radio PIRs The Supervision signal from the Radio PIR tells the panel that the device has not been removed from radio range and is in working order A non SUPERVISION enabled Radio PIR will transmit signals to the panel only when it has detected an event Obviously there is no guaranteed signal period Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL E PROGRAMMING PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Supervision Reset output disabled RELATED OPTIONS P65E Supervised Zones PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Supervision Strobe output disabled RELATED OPTIONS P65E Supervised Zones PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT OFF Supervision Keypad Sonalert disabled NOTES When this option is turned ON it delays the operation of all other selected Supervision outputs by one minute RELATED OPTIONS P65E Supervised Zones m Supervision alarms to RESET o
155. ware for easier remote programming with fast up download Even more events saved in memory for access by NessComms New polycarbonate housing with ample provision for the main board slide in accessory boards and backup battery New slide fit accessory boards with removable terminal blocks 106 011 Output Expander provides multiple outputs for various alarms amp user codes 106 012 Reader Interface Board provides for connection of up to 3 weigand readers 106 013 Relay Output Board provides 4 x C O relays for door strikes etc Combined installation and user manuals for both D8x and D16x models EZ Ness D8x D16x ConTROL PANEL INSTALLATION MANUAL NESS D8 AND D16 CONTROL PANELS PACKING LIST 1 D8 or D16 Main board 1 Housing 1 Ness LED keypad 100 192 or Ness LCD keypad 100 667 1 17VAC plug pack 1 12V 7Ah battery optional 1 Dialler telephone lead 1 User manual 1 Installer manual 9 or 17 End Of Line resistors 2K2 D8 D16 1 Lead assembly for battery 1 Lead assembly for internal tamper 1 Zone list label 2 Housing cover screws 4 Circuit board standoffs 106 000 D8x Panel with LED keypad 106 001 D8x Panel with LCD keypad 106 004 D16x Panel with LCD keypad Ness D8x SPECIFICATIONS Box dimensions 235W x 300h x 90d mm Ness D1 6x Plug pack 240V AC output 17V AC 21 4A Power supply 13 8V DC 9 800mA CONTROL PANELS Quiescent current draw 80mA with 1 keypad
156. ystem is disarmed For example this is often used to arm door and windows sensors overnight while allowing free movement within the house Monitor Mode will not work if Area 1 is armed Zones which are to be armed in Monitor Mode are selected using option P51E Monitor Mode can be armed by Keypad MONITOR code E or MONITOR E Radio Key See option P69E 5E Access Card Audible outputs in Monitor Mode set by options 6 1E 4E are independent of audible outputs in fully armed mode If dialler reporting is enabled Monitor Mode alarms will be reported as normal providing that a The zone s are selected to report alarms by option P74E b Options P64E 1E amp are off Brief Monitor Alarm Monitor Entry Delay2 Zones selected to be Entry Delay1 zones also have entry delay in Monitor Mode If Monitor Zones Entry Delay2 P64E SE is enabled then a Monitor zones will have entry delay as set by P27E Monitor Mode will not arm if there are no Monitor zones programmed P51E device such as a buzzer to be connected for day zone warning This may be needed if an additional audible day zone warning is needed although the keypad sonalert 6 7E is more than adequate in most cases RELATED OPTIONS P64E 2E Brief Day Alarm Turn this option onto enable Temporary Day Zones Factory default OFF P63E 5E Day Mode to Reset output P63E 6E Day Mode to Strobe output If P64E 2E is ON then this optio