Home

Electronic Keypad Lever Installation Instr.

image

Contents

1. KEYPAD ELECTRONIC LEVER amp KNOB INSTALLATION INSTRUCTION The BACKSET is the distance between the center of cross bore and edge bore of the door Adjustable latch fits both BACKSET of 2 3 8 60mm and 2 3 4 70mm Please follow the steps shown below for BACKSET adjustment a The backset shown on the left is 60mm 2 3 8 b Pull the cam toward right to extend the backset to 70mm 2 3 4 c The backset shown in figure C is 70mm 2 3 4 Pull the cam back to left will return the backset to 60mm 2 3 8 Note The shape of cam should be square a b c q 7 ry g re 2a 1 Mark The Door With Template Select the height and backset as desired on the door face use the TEMPLATE as an indication to mark the center of the circle on the door face and the center of the door edge 2 Drill Holes Using the marks as a guide to drill a hole 2 1 8 54mm through the door face for the lockset then a hole of 1 25 4mm for latch M QO DoC Oo 3 Identify Door Handing Face the door from outside the door is left handed if the hinge is on the left hand side of the door whereas the door is right handed if the hinge is on the right hand side of the door Interior Door Hinge t e n Left Handed Exterior Right Handed 4 Install Latch a Insert the latch and lay the faceplate against the door edge Use a pe
2. a za nS TI Os L A O fa a ON TE t D gt A 253 Qo Q 33 aa 7 3 ga o foc T 2 w A 8 Z WWO9 1ISXDV4 HOS abpa 100p uo asay I4 Z b E Z WWOL 1ISXDY4 HOS l ALVIdINAL u8 L Z WSS Limited Warranty Statements 1 Warranty Tong Lung Metal Industry Co Ltd hereafter TL warrants the Product to be free from defects in material and workmanship for a period of 12 months from the original date of purchase If you discover a defect in the Product covered by this warranty we will repair or replace the item at our option using new or refurbished components 2 Exclusions This warranty covers defects in manufacturing discovered while using the Products as recommended by TL rather than occurred by the act of God and damages caused by misuse abuse and unauthorized modification 3 Limited of Liability TL will not be held liable for incidental or consequential losses or damages to any act of God 4 Reminder Service requirement shall subject to the presentation of this warrant card and defective parts to the manufacture TL The warranty card will not be reissued if lost Product KEYPAD ELECTRONIC KNOB amp LEVER LOCK Purchase Date Name amp Address of Distributor KEYPAD ELECTRONIC KNOB amp LEVER LOCK USER MANUAL a Attention Please do not use the electronic screwdriver for installation
3. b Remove the cylinder from lever and insert it into opposite lever Then install the levers and make sure the small hole on the neck of lever aligns over the catch perfectly Rotate the levers to see if it operates well Programming Button Programming Button is for entering codes clearing errors and setting function It s also a lock button Number Buttons nput the user codes each user code is 4 10 digits in length 3 Cylinder Lock Unlock the lockset from exterior Gasket Prevent water permeating into lockset Battery Lid Slide the lid to change the batteries Battery Holder Four AA 1 5V Alkaline batteries R Button Reset Restore default setting Turn Button Lock Unlock the lockset from interior Cylinder E Specification Function 1 Power 6V four AA 1 5V Alkaline batteries 2 Low Battery 2 1 The batteries should be changed immediately once you see button flashes in red and hear 10 rapid beep sounds when press programming button 2 2 All settings are retained in the memory and will not be affected even if the battery is completely dead 2 3 The lock still can be operated by key even there is a power outage 3 1lluminated Indicator 3 1 Button1 flashes in green once when successful operation 3 2 Button flashes in green twice when successful programming 3 3 Button flashes in red 3 times when there is an operation error 3 4 Button flashes in red 5 times wh
4. through cam of the latch Tailpiece D HO Ax Tailpiece should be turned to vertical Outside Knob b Pass the IC wire over the latch to the interior side of door 7 Install Inside Mounting Plate Pass the IC wire through the wire hole on the mounting plate and fix the mounting plate with screws If outside lock assembly is lopsided please loosen the screws to adjust it s position and tighten the screws again 8 Install Receiver Module a Remove the battery cover push it up and pull it out b Connect the IC wire and ensure the turn piece is horizontal so that the tailpiece is able to engaged with the inside lever knob Then attach receiver module to the door with screws It s optional to use the attached wood screw Wood screw only for wood door b Battery wood screw a Cover o fi j i i screws Hs ilk ba Receiver 1 Module co c Insert 4 AA 1 5V alkaline batteries and put the battery cover back to the receiver module c Inside Lever Inside Knob 9 Change Lever Handing a Be sure the levers are unlocked Insert the provided pin wrench into the small hole on the neck of lever and apply pressure to depress the catch and pull out the lever from the stem Follow the same steps to remove interior lever and exchange the position of inside and outside levers
5. ar 3 long beeps
6. e mp G Remark Auto locking and Keypad locking function will be invalid when User Codes are deleted The lock can only be operated by key during the time Change Programming Code Enter PC gt MaxGrade gt 4 MaxGrade mp Enter New PC p Maxtirade Toggle Autolock On Off Enter PC gt MaxGrade Remark The preset delay time is 30 seconds you can change the time by following instruction Repeat the steps to cancel the Auto locking function Set Autolock Time Delay Enter Second Enter PC MaxGrade gt ae s Remark 10 99 seconds delay time available 11 Programming Code PC USER Code UC Toggle Mute On Off Enter PC Maxfirade mp Q gt Remark Repeat same steps to turn beeper On Off LED illumination is still functioning when it s in mute But there will be no any warning alarm Enable Disable All User Code Catt Remark Auto locking and Keypad locking function will be invalid when User Codes are disabled The lock can only be operated by key during the time Repeat the steps to enable the User Codes again Create a disposable User Code Enter new Enter PC mp MaxGrade 9 disposable UC Remark Disposable code will be no longer valid once being used Restore all preset lock settings Press R Remark Press R button for over 5 seconds the programming will complete after you he
7. en codes input error the system will shut down for system protection Refer to 17 3 5 Button flashes in orange 3 times when system has been restored to default setting 3 6 Button flashes in orange slowly while in programming mode 4 Audible Indicator 4 1 1 beep sound indicates a successful operation 4 2 2 long beeps indicate a successful programming 4 3 3 beeps indicate an operation error 4 4 3 long beeps indicate that system has been restored to default setting 4 5 5 beeps when codes input error the system will shut down for system protection Refer to 17 4 6 10 rapid beeps indicate the power of battery is low 5 Programming Code 5 1 The preset Programming Code is 0000 Please change it into new one when first time operation 5 2 Only one set of Programming Code for function setting 5 3 Programming Code is only for function setting you can t unlock the lockset by entering Programming Code 5 4 Programming Code is 4 10 digits in length 5 5 Programming Code can be changed anytime if needed 6 User Code 6 1 The preset User Code is 1234 Please delete it and create new one when first time operation 6 2 Up to 6 sets of User Codes can be saved 6 3 User Code is only for unlocking the lock without programming function 6 4 User Code is 4 10 digits in length 6 5 User Code can be deleted or added anytime if needed 7 Delete Individual User Code 7 1 User Codes can be deleted individually You can re set the
8. ncil to mark it s perimeter then take out the latch b Chisel out the portion you ve marked with pencil for about 4mm 5 32 deep Score the area within the borders as clearly and precisely as possible Ensure the plate can fit flush with the door edge surface c Insert the latch and tighten it with screws Be sure the holes for thru bolts next to the adjustable f cam should be horizontally aligned d There is no necessary to chisel the door edge for the faceplate installation if you use the drive in latch You may install it into the edge bore directly but be sure the bevel should face the outside assembly 5 Install Strike Ny BU a a Half close the door to lay the latchbolt against the door frame Mark the position of faceplate as an indication Place the strike against the door frame and mark it s erimeter Be sure the center of strike is perfectly aligned with the center of faceplate b Drill a 25 4mm 1 hole with 13mm 1 2 depth on the center of strike outline Then use the chisel to scrape out the door frame for 1 6mm 1 16 deep within your pencil mark Ensure to chisel deep enough to allow the strike lay flush with the frame surface c Insert the strike and tighten it with screws Note please use tapping screws for metal door 6 Install Keypad Assembly a Place the leverset knobset against keypad with tailpiece in vertical position inserted
9. same number as code even it s deleted before 7 2 Programming Code is needed when deleting individual User Code 8 Delete All User Codes At Once 8 1 All the User Codes can be deleted at once You can still reset the same numbers as codes even they re deleted before 8 2 Auto locking and Keypad locking function will be invalid after deleting all User Codes and the lock can only be operated by key These functions will be restored when recreate new User Codes 8 3 Programming Code is needed when deleting all User Codes 9 Temporarily Disable All User Codes 9 1 Auto locking and Keypad locking function will be invalid when User Codes are temporarily disabled The lock can only be operated by key during the time 9 2 Repeat the programming steps again to restore the auto locking keypad locking function and User Codes 10 Create a Disposable User Code 0 1 Disposable User Code will be no longer valid once being used 0 2 You can reset same number as Disposal User Code again 0 3 Programming Code is needed when creating a Disposable User Code 11 Restore Preset Factory Code 1 1 You can restore Preset Factory Code by pressing R button on the interior receiver module when you forget Programming Code or you want to cancel all previous setting 1 2 After restore the Programming Code would be 0000 the User Code would be 1234 again 12 Unlock the door 12 1 The lockset will be unlocked by key or pressing User Code on ke
10. unction set up when first time operation base on safety consideration 3 LED flashes orange slowly while programming LED flashes green twice with 2 long beeps when correct input LED flashes red 3 times with 3 beeps when incorrect input You need to wait for 6 seconds or press programming button when incorrect input then the system will be operative again 4 Each programming step should be done within 6 seconds 5 You can lock unlock this product by either key or keypad Please refer to the following programming table for function set up E Remark 1 We recommend to use alkaline battery in order to stabilize the power supply 2 Do not mix alkaline battery with regular zinc carbon ones or mixed brands 3 Do not use any chemical liquid or lubricating oil with additives to clean the lock body it will damage the surface or even mainboard 4 If there is any problem of the product please contact your local retailer and send back the product to us for repair or replacement Programming Code PC USER Code UC E Function Programming Add New User Code Enter PC m gt MaxGrade gt gt MaxGrade Enter New uc MaxGrade Remark Up to 6 sets of User Code can be saved User Code should be 4 10 digits in length Delete An Existing User Code Enter the UC Enter PC mp MaxGrade B gt youwantto gt delete Delete All User Code At once Enter PC MaxGrad
11. ypad from outside or by interior turn button 12 2 To unlock the door on the keypad enter the User Code and then press the Programming Enter button 13 Lock the door The lockset will be locked by key or pressing Programming Button on keypad from outside or by interior turn button 14 To Activate Deactivate Auto Locking Function 14 1 The lockset will automatically lock itself within 10 99 seconds when this function is programmed 14 2 This function is not preset at the beginning it can be set if needed 14 3 The preset delay time is 30 seconds you can adjust the period as you want 14 4 Please repeat the same programming steps to cancel Auto Locking function when needed 15 Toggle Mute On Off 5 1 You will hear beep sounds when pressing keypad programming or operating errors It can be turned off if needed 5 2 LED Illumination is still functioning when it s in mute For there will be no any warning alarm we suggest not to mute the beeper if it s not necessary 5 3 Motor operating sound cannot be muted 16 Code Protection Function The system will shut down if entering unauthorized codes over 5 times The System will be operative again after 45 sec 17 1llumination The LED Keypad will light up when pressing any button for ease of operating in the dark E Pass Code amp Function Set up 1 It should be under unlock status while programming 2 Please change default Programming Code 0000 and User Code 1234 before

Download Pdf Manuals

image

Related Search

Related Contents

EZ Zone PM User Manual  DScan User Manual Version 1.1 - us dental depot supply miami  Cobra Electronics 6000 Pro HD Quick Start Guide  pj x3131 pj wx3131 pj x3241 datenprojektor  (D) Bedienungsanleitung  Marquant MMP4-20  Appendice alla tastiera CS5500  Paxos compact Montageanleitung franz.sisch 302.535.42  

Copyright © All rights reserved.
Failed to retrieve file