Home
HP-500 Manual-OZSL
Contents
1. 1 2m hose to the ozone outlet and a diffuser stone to the other end of hose 4 2 For air treatment it is recommended to run without the hose connecting to the ozone outlet 5 Plug in the power plug into a power outlet WARNING Use only the rated voltage indicated on the product information label The product information label is affixed on the case last set OPERATING THE UNIT Press the power switch to turn the power on The LED Display will indicate a timer time Turning the ozone output adjuster to adjust ozone output The LED Display will indicate Ozone output There are 9 types g 83 0 3 O OD 4 6 0 59 7 9 Ozone m a Output 40 50 80 1 00 1204 140 160e 1807 200 me ihr The minimum ozone level is less than 40 of the max output 3 1 Using the Timer 3 1a 3 1b 3 1c Note Press the 2 key or the key once to either increase or decrease the timer time 01 03 05 10 20 30 40 50 60 70 80 90 Press repeatedly until you reach the desired timer time The maximum timer time is 90 min The minimum timer time is 0 min displaying 00 Press the 2 key to start working The timer time starts blinking and counting down in a l minute interval When the timer time reaches 00 the unit will stop After 3 sec the LED will again indicate the timer time last set To pause timing press the key This will pause working too The LED display will indicate the timer time last shown
2. using a Venturi inlet check for the presence of a vacuum WARRANTY Ozone Solutions warrants the new instruments to be free of defects for a period of one year from the date of shipment Ozone Solutions will repair or replace defective instruments provided it has been properly installed operated and maintained in accordance with this manual The option to repair or replace will be the exclusive decision of Ozone Solutions Damage Caused by Improper or Unintended Use of this Product Will Automatically Void this Warranty MAKING A CLAIM If you believe that this product is not operating satisfactorily you must 1 Contact us by email at support ozonesolutions com 2 Provide us with your name model and serial number and the date of purchase 3 Explain your problem clearly You will be advised by Ozone Solutions if you need to return the unit for servicing Please note that the purchaser is responsible for all return shipping costs Ozone Solutions is not responsible for incoming freight costs Ozone Solutions Inc Address 451 Black Forest Road Hull Iowa 51239 USA Email support ozonesolutions com Website www ozonesolutions com
3. Ozone Solutions CE HP 500 Ozone Generator With proper care and maintenance this device should give you years of trouble free service Please take the time to read this manual so that you may safely operate your ozone generator and utilize the unique properties of ozone SPECIFICATIONS Model Name HP 500 Max Ozone Output 200mg h without connection to air dryer 500mg hr with connection to air dryer Ozone output adjustable Internal Air Pump Output 1 2 L min Wattage 10W Timer 1 3 5 10 20 30 90min timers and constant ON function Pump Pressure 2 3 PSI 14 19Kpa Atmosphere standard 14 50 0 5 PSI 100 4 Kpa Ambient Temperature 0 104F 40 C Relative Humidity lt 80 Ozone Generating Method Corona Discharge Ozone Tube Gas Resource Ambient Air Air inlet Dim 3 16 inch 6mm Outlet Dim 3 16 inch 6mm Power Source AC120 60Hz or a 240V 50Hz model is available Body Size 4 52 x 8 46 x 2 16 inches 115mm x 215mm x 55mm Net Weight 1 63 lbs 750g Power Cable 48 inches 1 2m in length Case Plastic Accessories Included 2 sets of hose amp diffuser stone air dryer SAFETY WARNINGS HEALTH HAZARD WARNING 1 Permissible Exposure Limits The following limits accepted in USA UK and other parts of Europe gt gt 8 hour per day 5 days per week occupational exposure limit 0 1 ppm 15 minute short term exposure limit 0 3 ppm The HP 500 ozone generator 1s capable of d
4. before the pause To resume timing press key again OR To stop working immediately switch the power switch to turn the power off To restart repeat from the stepl When the timer time is set at 00 key is not functioning To adjust the timer time during count down either press on or key To switch to the Constant On mode when it is working under timer mode press 4 and hold the key for 3 sec If the timer was last used before turning the power off after turning the power on the LED will indicate a timer time last set 3 2 Using the Constant ON Mode 3 2a 3 2b Note Press and hold the o Key for 3 sec The LED display will show ON to indicate the unit is in the Constant On mode The unit will start immediately after ON 1s shown To stop working under Constant on mode press the key The LED display will indicate a timer time last set To resume Constant On press o key again and repeat the step 3 2a OR To stop working immediately switch the power switch to turn the power off To restart switch the power switch to turn on the power To switch to the timer mode when it s working under Constant on mode press the O and follow the instruction 3 1 During Constant On Mode the 2 and keys are not functioning If the Constant ON mode was last used before turning the power off after turning the power on the LED will indicate ON The unit will star
5. covered by warranty DO NOT open temper or try to repair the unit The unit utilizes very high voltages that can result in injury Do not touch an opened or tempered unit while it is working DO NOT operate the unit in humid conditions Relative Humidity gt 80 The suggested minimum room space is 1059 cubic feet 30m3 to avoid very strong smell of ozone when purifying air Keep the unit at a place where the unit is not reachable by children Unplug when you no longer need it DO NOT use unit within an environment with flammable gases or explosive materials DO NOT touch the machine with wet or damp hands Avoid using the unit repeatedly in the warehouse of metals and lactoprene any of several synthetic rubber materials Use only ozone compatible hoses between the ozone generator and the injection point Failure to use the correct materials could result in an undesirable leakage of ozone into the surrounding airspace DO NOT lubricate fittings or hoses with mineral oil or grease DO NOT place the unit on the carpet when using IMPORTANT WARNING Ozone Solutions accepts no liability for any damage or injury caused by this product or damages that may arise through its use by the purchaser or by others The purchaser is responsible for ensuring that the unit is correctly installed operated and properly maintained UNIT DESCRIPTION What Is in The Box 1 HP 500 l Air Dryer 200ml and 1 connecting hose 4 inch 10 cm 2 hoses
6. ea 48 inch 1 2m 2 diffuser stones 1 HP 500 user s manual l Air Dryer user s manual Control Panel bi M Ozone Outlet Air Inlet Power Switch Air Dryer The power switch to turn on the power of the unit is at the right side of the generator The air inlet is at the front side of the generator The ozone outlet is at the left side corner The control panel is on the top side of the unit LED Display Ozone Output ON OFF UP DOWN Adjust Controls Function HT Indicates Ozone output 9 modes LED Display Indicates timer time 00 01 03 05 10 20 30 90 min Indicates Constant ON Mode ON Press it to start working ON OFF Press 1t to stop working Press and hold it for 3 sec to switch to Constant On mode DOWN Each press decreases the timer time by 10 min down to 90 min nn u Each press increase the output from 40mg hr to 200mg hr by 20mg hr up Each press increases the timer time by 10 min up to 90 min BEFORE USE PREPARATION 1 Ensure that all hoses are free from dust or other contaminants before connecting 2 Connect one end of 4 inch 10cm hose to an air inlet either one of Air Dryer 3 Connect the other end of the 4 inch 10cm hose to the air inlet of the unit WARNING Avoid using a hose longer than 4 inches 10cm to make the connection to the Air Dryer as an overly long hose can overload the internal air pump and cause a premature failure 4 1 For water liquid treatments connect the 4 ft
7. elivering up to 200 gram of ozone per hour In an enclosed space the ozone concentration generated by the HP 500 quickly exceeds the 15 minute exposure limit of 0 3 parts per million 2 Toxicology of ozone Above the exposure limit there is risk of inflammation to the respiratory system Ozone has been shown to induce asthma attacks People with history of asthma episodes should not enter a newly ozonized area until all the residual ozone has fully dispersed and the area well ventilated with fresh air Ozone has a distinctive sharp odor and is detectable by smell even at concentrations well below the 15 minute exposure limit Most people can detect the smell of ozone at concentrations around 1 10 of the 15 minute exposure limit A strong smell of ozone normally indicates an ozone concentration that exceeds the 15 minute exposure limit WARNING gt People with smell disorder should not operate this equipment gt Leave some room for the unit when using gt Don t attempt to confirm ozone production by directly smelling the ozone coming out of the unit gt Short term inhalation of high concentrations of ozone and long term inhalation of low concentrations of ozone can cause serious harmful physiological effects Do not directly inhale ozone gas produced by this device GENERAL SAFETY WARNINGS 1 A u a 10 11 12 The unit is not waterproof for indoor uses only DO NOT allow water to enter Water damage is not
8. t working after 3 sec WARNING To avoid overheating when running it for an extended period of time keep the area around the generator free from obstructions to maximize air movement and use an external fan if possible GUIDANCE FOR APPLYING OZONE TREATMENT For any liquid treatment place the unit at least 4 inches 10cm above the liquid s surface to prevent 1t from entering the generator For air treatment it is recommended to run without the hose connecting to the ozone outlet WARNING Place the unit at least 4 Inches 10cm above the liquid s surface to prevent backflow RESERVE The packing product should be reserved under such conditions l Ambient Temperature 0 104F 40 C Relative Humidity 80 Atmosphere standard 14 50 0 5 PSI 10044 Kpa Indoor without corrosive gases and well ventilated u os MAINTENANCE If you only use your ozone generator intermittently you should store the device in a dry place when not in use and protect it from dust with a plastic bag If you choose to use an automated ozone delivery system carry out regular inspections to ensure that your system 1s working effectively Examine all hoses and connections for leaks or damage Check air pump flow rates Examine check valves for effectiveness Replace or clean dirty particulate filters Replace or recharge the Air Dryer for more info please see its user s manual Check the diffuser for an efficient bubble pattern or if
Download Pdf Manuals
Related Search
Related Contents
PEP - Mentor/Educator User Guide thermoregulateur electronique digital avec PAT iFlex5 LMI Service Manual X1 Portable High Resolution Lossless DAP / Music Player Quick Bosch ISN-GMX-W0 mounting kit ー 施工説明書 ー PASSEO SL2 La biodiversité - Ministère de l`écologie, du développement durable White Rabbit PTP Core User's Manual fx2n-10pg pulse generator block installation manual Copyright © All rights reserved.
Failed to retrieve file