Home

IM iTM plus adaptor DCM601A52

image

Contents

1. 3 2 1 Removal from DIN rail D Pull down the lever at the lower portion of the iTM plus adaptor and pull the unit body out D toward you English Installation Manual 3P291714 3 23 DCM601A52 iTM plus adaptor 01_EN_3P291714 3 indd 23 D 5 18 2011 12 04 58 PM n 4 1 24 01_EN_3P291714 3 indd 24 Assigning a DIII NET address for each air condi tioner In a DIII NET system there is a management number for identifying each air conditioner This can be referred to as DIII NET address A DIII NET address needs to be assigned manually using the remote controller for each air conditioner There are remote controllers of several types each requiring a different way of assigning a DIII NET address This section describes commonly used two types of remote control lers wired and navigation remote controllers as examples CAUTION e Make sure that the iTM plus adaptor is connected to the intelligent Touch Man ager and that both units are powered on Unless both are powered on you cannot perform DIII NET address assignment for your air conditioners e For how to assign addresses for HRV Heat Reclaim Ventilation equipment and various adapters such as a universal adapter refer to the manual for each product Remote controller buttons and areas
2. Power supply 100 240VAC 50 60Hz Earth Secure cables with cable ties T1 MO Ov gt Location of cable mount Installation Manual 3P291714 3 DCM601A52_ iTM plus adaptor 3 B c 3 A M 8 A a S E amp D TU _ F Cable mount Breaker 19 2 4 2 20 01_EN_3P291714 3 indd 20 e ia Requirements that must be met e Cable type Ordinary tough rubber sheathed cord 60245 IEC 53 equivalent or higher Ordinary polyvinyl tough chloride sheathed cord 60227 IEC 53 equivalent or higher e Core thickness 1 0 2 0 mm e Terminal treatment Use a round crimp type terminal M4 with insulating sleeve e Power supply voltage Single phase 100 to 240 VAC at 50 60 Hz e Voltage fluctuation 10 or less e Electric power consumption 6 W CAUTION e The power supply requires circuit breaker 10A installation and earth wire connection e After installing a circuit breaker be sure to connect only the iTM plus adaptor to it e To prevent accidents due to wire breakage or disconnection secure the power supply cables to the blue resin cable mount with cable ties e Be sure to connect the earth wire e For the earth wire use a green wire with yellow stripes Do not connect the earth wire to gas or water pipes lighting rod or telephone earth wire Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor D 5 18 2
3. plus ADP IF The terminals for connecting an intelligent Touch Manager or iTM plus adaptor installed in parallel DIII The communication line connection terminals for DIII NET which enables communications with DAIKIN s air conditioning equipment Di The terminals for connecting an external signal input device for stopping air con ditioners in an emergency or for connecting electric energy meters for calculating the electricity usage of individual indoor air conditioning units RESERVE No Use POWER The power line connection terminals These terminals are covered with a protective cover A power supply voltage of 100 to 240 VAC at 50 60 Hz is required Near this terminal block there is a blue resin cable mount used for securing the power supply cables with cable ties plus ADP ADDRESS The switch for selecting the address of the iTM plus adaptor For each iTM plus adaptor set a unique number between 2 to 8 TERM The switch used when multiple iTM plus adaptors are connected in parallel for enabling the termination resistor on the furthest iTM plus adaptor from the intelli gent Touch Manager DIII MASTER The switch used when there are two or more DIII NET centralized controllers such as intelligent Touch Managers are connected for distinguishing between the MASTER and the SLAVE controllers RESET The switch for restarting the iTM plus adaptor Tx Green T
4. lt Step 4 gt y gg GROUPE ip OU ta SETTING 5 Press the Timer ON OFF button to make the GROUP indicator stay lit The DIII NET address has been set lt Step 5 gt mn GROUP 7 LILI SETTING 6 Press the Inspection Test Operation button You are now brought back to the screen shown in Step 6 2 lt Step 6 1 gt rir GROUP j 7 LILI SETTING lt Step 6 2 gt 30 Lic 26 Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor 01_EN_3P291714 3 indd 26 D 5 18 2011 12 04 59 PM n E 4 1 2 Procedure for a navigation remote controller The following describes how to assign a DIII NET address when a navigation remote controller is installed NOTE You cannot perform the following procedure when the display backlight is off In this case press any key to turn on the backlight before starting the procedure 1 Press and hold the Cancel button for 4 seconds or more The Field setting menu is displayed lt Step 1 gt 00 00 Set temp Room Cool
5. DAIKIN Installation Manual ITM plus adaptor Model DCM601A52 Safety Precautions Also see installation manual attached to equipment you connect Please read these SAFETY PRECAUTIONS carefully before installing air condi 01_EN_3P291714 3 indd 2 tioning unit and be sure to install it correctly They both contain important information regarding safety Be sure to observe all precau tions without fail A WARNING Failure to follow these instructions properly may result in personal injury or loss of life Failure to observe these instructions properly may result A CAUTION in property damage or personal injury which may be seri ous depending on the circumstances e After completing installation conduct a trial operation to check for faults and explain to the customer how to operate the air conditioner and take care of it with the aid of the operation manual Ask the customer to store the installation manual along with the operation manual for future reference A WARNING Ask your dealer or qualified personnel to carry out installation work Do not attempt to install the unit yourself Improper installation may result in an electric shock or fire Do not relocate or reinstall the unit yourself Improper installation work may result in an electric shock or fire Ask your local dealer to carry out relocation and reinstallat
6. In a domestic environment this product may cause radio interference In such case the user may be required to take adequate measures Disposal requirements Dismantling of the unit treatment of the refrigerant of oil and of other parts must be done in accordance with relevant local and national legislation To ensure your safety be sure to lock the control enclosure door except during mainte nance Fill the wiring through hole with putty Entry of water or insects may result in electric leakage or malfunction Do not operate with wet hands An electric shocks and malfunction may be caused Do not wash this unit with water An electric shock or fire may be caused Install the indoor and outdoor units power cord and connecting wires at least 1 meter away from televisions or radios This is to prevent picture interference and noise Depending on the incoming signal strength a distance of 1 meter may not be sufficient to eliminate noise Do not install the unit in the following places 1 Where there is a high concentration of mineral oil spray or vapor e g a kitchen Plastic parts will deteriorate parts may fall off and water leakage could result 2 Near machinery emitting electromagnetic radiation Electromagnetic radiation may disturb the operation of the control system and result in a malfunction of the unit 3 Where flammable gas may leak where there is carbon fibre or ignitable dust suspen
7. The names of buttons and areas of a wired remote controller used in this section are shown below lt Wired remote controller gt Address display area Parameter number display area Programming time buttons Temperature setting buttons Timer ON OFF button Inspection Test operation button T1 MO OO WwW gt The names of buttons and areas of a navigation remote controller used in this section are shown below lt Navigation Remote controller gt Display Up button Menu Enter button Right button Cancel button T1 MO OO gt Down button Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor D 5 18 2011 12 04 58 PM n English 01_EN_3P291714 3 indd 25 Procedure for a wired remote controller The following describes how to assign a DIII NET address when a wired remote controller is installed NOTE a Da LE After power on the controller shows the symbol 22 for about 1 minute after displaying all information on its display During this period it may not accept your operation If so a Du 1 try operating the remote controller again after 33 disappears 1 Press and hold the Inspection Test Operation button for 4 seconds or more SETTING appears in the center of remote controller display lt Step 1 gt ee
8. gt West A 001 West 8 001 BS AC 01 AC 01 v West ACO1 Mooc Cooling ae Details GO Start My Setpoint EEE Fan Speed _ A lt Setting Mon 20 Jun AM10 20 Installation Manual DCM601A52 iTM plus adaptor 3P291714 3 C Touch the Out button to go to the area one level above the current area 31 6 3 32 01_EN_3P291714 3 indd 32 Starting stopping an area or management point Top gt 10F gt Office A West ACO1 4 A Q Top 7 in ou Bus D a Lt Ly S A D NS AS S SS Setting AC 01 AC 01 AC 01 AC 01 AC 01 Mer Standard Layou Mon 20 Jun Top gt 10F gt Office A West ACO1 Top 47 in out Bist Sp Poc Al Cooling 001 ao oot oot oot con Sur o1 WestA 001 WestA 001 WestA 001 WestA 001 Setpoint _ katla e on WeskB 001 WestB 001 WestB 001 West 8 001 Fan Speed NS NS S SS 4 A 001 acn acn ACO ACO v S S S ae AC 01 AC 01 AC 01 AC 01 AC 01 Y 7 Standard Tayou Mon 20 Jun A Select the area or management point you want to start or stop B On the On Off combo box select Start or Stop to start or stop the area management point respectively The icon is green or red depending on the system setup when the area management point is started operating and gray when stopped Confirm MBATWET A C e ne Confirm BL
9. list format This chapter describes how to start stop the areas and management points registered with the intelligent Touch Manager and display their information quickly For detailed oper ation procedures refer to the users manual 5 Top gt 10F gt Office A Top 47 in out A 001 001 om 001 ot 001 West A 001 WestA 001 West A001 West A 001 001 West B 001 WeskB 001 WestB 001 West B 001 SS SNS RS 001 AC 01 AC 01 AC 01 AC 01 Ss S AS SN N AC 01 AC 01 AC 01 AC 01 AC 01 D West ACO1 SS 2B TES Cooling ae Detaiis e rl Setpoint 24 ia Fan Speed _ a MA Setting Mon 20 Jun AM10 20 Top gt 10F gt Office A Top uni Az out Type indoor Een D anna Cooling coo Coating ccce Cooling po Cooino Eeee J bio FFFF Auto FFF Auto FFFF au FFFF Aut 10 C 20 C Af Bich ae Bl Auto al Low B AM Hoh AM Mice AH Mice Al Hot AHL Hoh Af Hon a Setting Mon 20 Jun AM10 20 A Touch the List button B The screen changes to the list view where the name operation mode set tempera ture and fan speed of all areas and indoor units are listed Viewing target areas and management points Too gt 10F gt Otfice A Top AY o B us oot 001 oo 001 oot oot West A001 WestA 001 West A 001 WestA 001 001 West B 001 West 00
10. A WARNING e Be sure to perform this procedure with the power supply turned off Doing so may cause an electric shock e Do not clamp the cables with high current lines such as a power cable NOTE Power distribution is available for a maximum of 64 air conditioners indoor units per DIII NET port Installation Manual 3P291714 3 17 DCM601A52 iTM plus adaptor D 5 18 2011 12 04 56 PM r 2 3 1 Terminals location and conceptual connection diagram Use the terminals located under the label Di to connect the pulse signal line The iTM plus adaptor accepts four types of signals through its four channel terminals Di1 Di2 Di3 and Di4 and two COM terminals ground lt Conceptual drawing of Di connec tion gt NOTE The COM terminals are all connected internally So you can use either of them However you can connect up to two wires simultaneously to each COM terminal Di1 Di2 COM Di3 Di4 COM 2 3 2 Requirements that must be met e Cable type CPEV cable e Core thickness 0 75 1 25 mm e Cable length 200 meters or less lt Pulse width gt e Pulse width 20 to 400 ms Pulse interval 100 ms or more A JL lL gt B A Pulse width 20 to 400 ms B Pulse interval 100 ms or more CAUTION e The contact connected to the contact input terminal must be capable of han dling 10 mA at 16 VDC e If an instan
11. CO aA 0 0 a Je lo 2 Using the Temperature Setting buttons change the value shown in the parameter num ber display area to OO In the address display area the current address setting is displayed This area will show if no address is set lt Step 2 gt O GROUP rae SETTING NOTE by The parameter number cannot be changed to uu when the intelligent Touch Manager is not powered on Power on the intelligent Touch Manager and wait for a while before trying to operate the by remote controller You cannot change the parameter number to uu also when the intel ligent Touch Manager is not communicating with the indoor units normally Make sure that the cables are connected correctly 3 Press the Timer ON OFF button to make the GROUP indicator blink You are now ready to change the DIII NET address lt Step 3 gt L Ivy ay GROUP VS FU sernne Installation Manual 3P291714 3 25 DCM601A52 iTM plus adaptor D 5 18 2011 12 04 58 PM 4 Using the Programming time buttons select the address you want to set
12. adaptor 2 3 English os 01_EN_3P291714 3 indd 17 lt DIII MASTER gt To set the iTM plus adaptor to SLAVE use the DIII MASTER switch located under the front slide cover Placing the switch in the upper position labeled as SLAVE changes it to a SLAVE To install multiple centralized controllers set only the highest priority controller to MAS TER and all other controllers to SLAVE according to the following order of priority 1 Interface for use in BACnet High 2 Interface for use in LONWORKS 3 intelligent Touch Manager MASTER iTM plus adaptor MASTER Priority 4 Central Remote Controller MASTER 5 intelligent Touch Manager SLAVE iTM plus adaptor SLAVE 6 Central Remote Controller SLAVE Low 7 ON OFF Controller MASTER 8 ON OFF Controller SLAVE ee eee ee e CALCULATE UNIT e intelligent Processing Unit e Parallel Interface e Intelligent Touch Controller e iTM plus adaptor e Residential Central Remote Controller e Schedule Timer e Electrical Appendices Connecting contact or pulse input equipment such as elec tric energy meters The iTM plus adaptor can be connected with an external signal input device for stopping air conditioners in an emergency or with electric energy meters for calculating the elec tricity usage of individual air conditioners when power distribution is enabled
13. adaptor with intelligent Touch Manager DIII NET compatible air conditioning devices and other equipment In addition to air conditioners the iTM plus adaptor can be connected and work with a wide range of equipment However the required connection procedures vary depending on the equipment to be connected e 2 1 Connecting intelligent Touch Manager e 2 2 Connecting DIII NET compatible air conditioning equipment e 2 4 Connecting power supply e 2 3 Connecting contact or pulse input equipment such as electric energy meters WARNING e Do not turn the power supply on until all connections are made Doing so may cause an electric shock e After completing connections check again that all wires are connected cor rectly before turning on the power supply CAUTION Provide a cable trap before the terminal block and perform wiring to prevent water entry Water splashing onto the terminal block may result in an electric shock or fire A Terminal block B With trap C Without trap Installation Manual 3P291714 3 11 DCM601A52 iTM plus adaptor D 5 18 2011 12 04 55 PM n 2 1 Connecting intelligent Touch Manager The iTM plus adaptor is a device that enables you to control more air conditioners with the intelligent Touch Manager It needs to be connected to an intelli
14. l 30 c 30 c 2 Using the Up Down buttons select Group No setting and press the Menu Enter but ton The Group No setting menu is displayed lt Step 2 gt Field setting Test operation ON OFF Register Service Contract D Field setting list D Group No setting Indoor unit Airnet No set Error record a Return Setting NOTE The Group No setting menu is not displayed when the intelligent Touch Manager is not powered on Power on the intelligent Touch Manager and wait for a while before trying to operate the remote controller The Group No setting menu is not displayed also when the intelligent Touch Manager is not communicating with the indoor units normally Make sure that the cables are connected correctly 3 Using the Up Down buttons select Group No setting Group and press the Menu Enter button The current address setting is displayed lt Step 3 gt Group No setting Group No setting Group Group No setting Unit ENE A OReturn Setting English Installation Manual 3P291714 3 27 DCM601A52 iTM plus adaptor 01_EN_3P291714 3 indd 27 D 5 18 2011 12 04 59 PM n 4 Press the Menu Enter button to release the current address setting The mode indication changes from Setting to Release You are now ready to change the DIII NET address lt St
15. met iii 12 2 1 3 Address setup and termination resistor eee cececeeneeeeeeeeneeeeeeeeneeeeeeeeeaeeeeeeeenaeeeeeeeaes 13 2 2 Connecting DIII NET compatible air conditioning equipment 14 2 2 1 Terminals location and conceptual connection diagram eeeeeeeeeeeneeeeeeeetteeeeeeeeaes 15 2 2 2 Requirements that must be met iii 16 2 2 3 Precautions for using multiple centralized Controllers ccceeeeeeeeeeeeeeneeeeeeeeneeeeeeeeaes 16 2 3 Connecting contact or pulse input equipment such as electric energy meters 00eee 17 2 3 1 Terminals location and conceptual connection diagram cccceceeeeeeeeeeeeeetteeeeeeeees 18 2 3 2 Requirements that must be Met iii 18 2 4 Connecting power SUPPLY iii 19 2 4 1 Terminals location and conceptual connection diagram eceeeeeeeeeeeeeeeeeneeeeeeeenaeees 19 2 4 2 Requirements that must be met iii 20 3 1424 ELLE LA Le PRE AR RE RER 21 3 1 Screw mounting to control enclosure is 21 9 1 1 Dimensions OT iTM plus adaptor ss seu username nee aineuneniinns 21 3 122 Installation proc dure assassin a stone nent en nie bbb asada 22 92 DIN alll MOUNTING 2586228888 ne etre need Nate trente ten etes den nd it ee 22 3 2 1 Removal from DIN rail ss dass nt sn et era ie nf mantieet ani mn dtuiens 23 4 Assigning a DIII NET address for each air conditioner sseeeeeeeeeeeeeees 24 4 1 Remote controller buttons And areas 24 4 1 1 Procedure for a wired rem
16. total wire length must be kept to 1500 meters or less Precautions for using multiple centralized controllers Equipment that controls multiple air conditioners is referred to as centralized controller DAIKIN s product portfolio includes a wide range of centralized controllers suited to differ ent applications or target sizes which can be used in combination to construct an optimal air conditioning system There is one thing you should be aware of when installing two or more centralized control lers in DIII NET That is you must establish a MASTER to SLAVE relationship among those controllers to prevent confusion in interpreting instructions to air conditioning equip ment The MASTER authority may be assigned to one controller only The remaining controllers must be set to SLAVE The iTM plus adaptor is set to MASTER by default Change the setting to SLAVE in any of the following cases e Where Interface for use in BACnet is installed in parallel e Where Interface for use in LONWORKS is installed in parallel e Where there is an intelligent Touch Manager that is set to MASTER which serves as the master of this iTM plus adaptor e Where there is another iTM plus adaptor that is set to MASTER which serves as the master of this iTM plus adaptor Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor D 5 18 2011 12 04 56 PM n Centralized con trollers that cannot D be installed in parallel with iTM plus
17. 011 12 04 55 PM n 2 2 1 English 01_EN_3P291714 3 indd 15 Terminals location and conceptual connection diagram To connect the DIII NET communication line use the two terminals F1 and F2 under the label DII which have no polarity These 2 terminals have no polarity An example of con necting more than 2 air conditioning devices is shown in the following conceptual connec tion diagram CAUTION Make sure that the wires you are connecting to the F1 and F2 terminals are not power wires Inadvertently connecting power wires to these terminals results in a failure of the air conditioner or iTM plus adaptor lt Conceptual connection diagram with air conditioning equipment gt A B Cc F1 F2 F1 F2 D D D D D F1 F2 P1 P2 F1 F2 P1 P2 F1 F2 P1 P2 F1 F2 P1 P2 F1 F2 P1 P2 a a E E ean ee E rene ee ee T1 M OO OO WwW gt Outdoor unit OUT OUT IN OUT Indoor unit A maximum of 16 indoor units can be connected per remote controller group A maximum of 64 remote controller gr
18. 011 12 04 57 PM 3 1 English 01_EN_3P291714 3 indd 21 Installation The iTM plus adaptor can be installed in the following two ways e Screw mounting to control enclosure e DIN rail mounting Screw mounting to control enclosure Dimensions of iTM plus adaptor The figure below shows the dimensions of the iTM plus adaptor A E E E g S TS v A Installation Manual 3P291714 3 21 DCM601A52 iTM plus adaptor D 5 18 2011 12 04 57 PM 3 1 2 Installation procedure Secure the iTM plus adaptor to the control enclosure using the supplied round head wood screws When done remove the blue protective film from the upper portion of the unit body lt Mounting to control enclosure gt 3 2 DIN rail mounting The iTM plus adaptor can be mounted to a 35 mm DIN rail lt Mounting to DIN rail gt Do not use screws to secure the iTM plus adaptor onto the DIN rail 22 Installation Manual 3P291714 3 English DCM601A52_ iTM plus adaptor 01_EN_3P291714 3 indd 22 D 5 18 2011 12 04 57 PM Place the iTM plus adaptor over the top of the DIN rail so that the upper hook 1 on the rear face is hooked and push it in direction 3 until the lower hook 2 snaps into the DIN rail When done remove the blue protective film from the upper portion of the unit body n
19. 1 West B 001 West 8 001 DS D SN D oot AC 01 Ac 01 AC 01 AC 01 D gt N D N A gt AC 01 AC 01 AC 01 AC 01 AC 01 ae West ACO1 Details Store ENCRES CLS Top gt 10F gt Office A Top 47 in Ay out Bust D oot o o 001 001 o1 WestA 001 WestA 001 WestA 001 WestA 001 o1 WestB 001 WestB 001 Wesk8 001 West B 001 gt S NS gt ont Acao ACO Aco ACO S S S AC 01 AC 01 aco ACO co lw West ACO1 gt Poc cooing ee Ono Start a Fe Fan Speed _ A a Ww Setting Mon 20 Jun AM10 20 Hs et Mon 20 Jun AM10 20 ment points in it A You can check the hierarchy level of the current area or indoor unit B Touch the In button to go to the area being selected and view the areas and manage Top gt 10F gt Office A 001 001 ont 001 001 ial Zon ama C 001 WestA001 WestA001 West A 001 WestA 001 001 West B 001 WestB 001 West B 001 West B 001 D SN SS SN 001 AC 01 AC 01 AC 01 AC 01 DS D gt AS gt DS AC 01 AC 01 AC 01 AC 01 AC 01 nue West ACO1 p MES Cooling 8 Details Store EE PER CES ES WestA 001 West A D01 Top gt 10F gt Office A Top Z In Az out 001 001 001 West A 001 001 West 8 001 oot ACO S SN Acao AC 01 WestB 001 West B D01 S NS AC 01 AC 01 D gt AC 01 ACO Est
20. EU ET AD C Le nl C When Confirmation Dialog is set to Enabled in the system setup the corresponding message appears Select the Yes button to confirm the Start Stop operation Installation Manual 3P291714 3 DCM601A52 iTM plus adaptor English 5 18 2011 12 05 01 PM 00_CV_3P291714 3 indd 2 3P291714 3 EM11A029 104 mT 5 13 2011 11 45 45 AM
21. V cable e Core thickness 0 65 0 9 mm e Cable length 50 meters or less in total for overall plus ADP IF wiring 12 Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor _____ 01_EN_3P291714 3 indd 12 D 5 18 2011 12 04 55 PM n English a 01_EN_3P291714 3 indd 13 Address setup and termination resistor You need to assign a unique address to each of your intelligent Touch Manager and the iTM plus adaptors connected to it Because the address of the intelligent Touch Manager is fixed to 1 each iTM plus adaptor must be given an address between 2 and 8 Turn the plus ADP ADDRESS switch located on the front face of each iTM plus adaptor to set a unique address You also need to enable the termination resistor on the furthest iTM plus adaptor from the intelligent Touch Manager This termination resistor setting is done using the TERM switch located on the front face of the iTM plus adaptor lt plus ADP ADDRESS switch and TERM switch gt NOTE If the two LEDs CPU ALIVE and ALARM both light up during power on after installa tion there is a possibility of a problem with the address assignment e An invalid address is set 0 1 and 9 are not allowed e A duplicate address is used You must assign a unique address between 2 and 8 for each iTM plus adaptor Power o
22. a mounting direction as described below e Installation place Indoor inside control enclosure which must be lockable or designed to be opened only with a special tool e Mounting direction Vertical only 1 4 2 Required space To install the iTM plus adaptor the following space is required Also note the following e Make sure that there is a minimum clearance of 20 mm between each unit and wiring ducts e When installing two or more units side by side they can be arranged without clearance in the horizontal direction Required installa tion space 149 2mm A Wiring duct English Installation Manual 3P291714 3 DCM601A52 iTM plus adaptor 01_EN_3P291714 3 indd 9 D 1 4 3 Environmental conditions The installation environment must meet the following conditions e Ambient temperature 10 to 50 C e Ambient humidity 85 RH or less without condensation 10 Installation Manual 3P291714 3 DCM601A52 iTM plus adaptor 01_EN_3P291714 3 indd 10 D English 5 18 2011 12 04 55 PM n Required proce dures Equipment spe cific procedures English 01_EN_3P291714 3 indd 11 Connection This chapter describes the procedure for connecting the iTM plus
23. anual An insufficient power supply capacity or improper electrical construction may lead to electric shocks or fire When wiring the power supply and connecting the remote controller wiring and trans mission wiring position the wires so that the electric parts box lid can be securely fas tened Improper positioning of the electric parts box lid may result in an abnormal heat build up electric shock or fire Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor D 5 18 2011 12 04 54 PM n A WARNING Be sure to earth the unit Do not earth the unit to a utility pipe lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or fire Do not change the protective equipment settings Otherwise a short circuit may occur in a pressure switch temperature switch or other protective equipment forcing the unit to operate unexpectedly In addition use of parts other than those specified by DAIKIN may result in firing Install an earth leakage breaker as required Failure to install an earth leakage breaker may result in electric shocks or fire CAUTION Be very careful about product transportation Safely dispose of the packing materials Tear apart and throw away plastic packaging bags so that children will not play with them If children play with a plastic bag which was not torn apart they face the risk of suffoca tion This unit is a class B product
24. ep 4 gt Group No setting Group Group No Set 1 00 Return Release 5 Using the Up Down buttons select the address you want to set lt Step 5 gt Group No setting Group Group No Release 1 00 Return Change kg 6 Press the Menu Enter button The DIII NET address has been set lt Step 6 gt Group No setting Group Group No Set 1 03 Return Release 7 Press the Cancel button three times You are now brought back to the screen shown in Step 7 2 lt Step 7 1 gt Group No setting Group Group No Set 1 03 Return Release p 00 00 Set temp lt Step 7 2 gt Cool a 30 c Room 30c 28 Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor 01_EN_3P291714 3 indd 28 D 5 18 2011 12 05 00 PM n English 01_EN_3P291714 3 indd 29 ns Setting an unique address to each unit when power distribution is enabled When power distribution is enabled you need to set a unique address for each unit For how to set an address refer to the commissioning manual Installation Manual 3P291714 3 29 DCM601A52 iTM plus adaptor D 5 18 2011 12 05 00 PM pae 5 1 30 a 01_EN_3P291714 3 indd 30 ie Outdoor Unit Address Setup For the intelligent Touch Manager to identify each outdoor unit you need t
25. ff the unit once check and correct the address and then turn it on again Check the status of the two LEDs CPU ALIVE and ALARM Installation Manual 3P291714 3 13 DCM601A52 iTM plus adaptor D 5 18 2011 12 04 55 PM 2 2 14 01_EN_3P291714 3 indd 14 Connecting DIII NET compatible air conditioning equipment DIII NET is a unique air conditioning equipment communication capability developed by DAIKIN Using DIII NET you can centrally control multiple DIII NET compatible air condi tioning devices by connecting them to your intelligent Touch Manager The iTM plus adaptor allows you to connect additional 64 groups of air conditioners per unit Considering that the intelligent Touch Manager can be connected with a maximum of seven iTM plus adaptors you can control a total of 512 groups of air conditioners at a maximum using a single intelligent Touch Manager N WARNING e Be sure to perform this procedure with the power supply turned off Doing so may cause an electric shock Do not clamp the cables with high current lines such as a power cable NOTE Each air conditioner controlled via an iTM plus adaptor is also assigned a DIII address between 1 00 to 4 15 From the intelligent Touch Manager it is recognized as 2 1 00 3 1 02 or the like with the DIII NET port number prefixed Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor D 5 18 2
26. gent Touch Manager to provide this capability 2 1 1 Terminals location and conceptual connection diagram Connect the terminals located in the plus ADP IF section of the iTM plus adaptor to the corresponding terminals located in the plus ADP IF section on the rear face of your intel ligent Touch Manager Note that these terminals have polarity Be sure to connect the positive wire to the terminal and the negative wire to the terminal respectively In addition the intelligent Touch Manager must be connected as a terminal to the wiring lt Terminals location and conceptual connection diagram gt Qala 9 Oa A _ intelligent Touch Manager Rear face B iTM plus adaptor C plus ADP IF intelligent Touch Manager D plus ADP IF iTM plus adaptor E iTM plus adaptor on which termination resistor must be enabled 2 1 2 Requirements that must be met e Cable type CPEV or FCPE
27. he indicator that indicates when on that data is being sent to the intel ligent Touch Manager Rx Orange The indicator that indicates when on that data is being received from the intelligent Touch Manager DIII MONITOR Yellow The indicator that indicates when on that data is being com municated with DIII NET CPU ALIVE Green The LED that indicates that the CPU is operating normally For the relationship between the LED status and the unit s operating condition refer to the LED status and operation table below ALARM Red The LED that turns on or blinks in the event of an error For the rela tionship between the LED status and the unit s operating condition refer to the LED status and operation table below Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor D 5 18 2011 12 04 54 PM n The table below shows the status of the CPU ALIVE ALARM LED when the iTM plus adaptor is operating normally or failed NOTE LED status and operation table Operating condition CPU ALIVE Normal Blink Hardware failure Off Address failure On plus ADP IF communication failure On 1 4 Determining installation place Be sure to install the iTM plus adaptor in a place that meets the conditions described in 1 4 1 through 1 4 3 1 4 1 Installation place and mounting direction Note that the iTM plus adaptor must be installed in a place and in
28. ion of the unit Install the unit in accordance with the instructions in this installation manual Improper installation may result in an electric shock or fire Be sure to use only the specified accessories and parts for installation work Failure to use the specified parts may result in the unit falling an electric shock or fire amp Install the unit on a foundation strong enough to withstand the weight of the unit A foundation of insufficient strength may result in the equipment falling and causing injury Always perform installation work with the power supply shut off Touching energized electric parts causes an electric shock Do not disassemble modify or repair the unit An electric shock or fire may be caused Make sure that all wiring is secured that the specified wires are used and that there is no strain on the terminal connections or wires Improper connection or securing of wires may result in abnormal heat build up or fire The choice of materials and installations must comply with the applicable national and international standards Carry out installation work taking earthquakes into account Failure to do so during installation work may result in the unit falling and causing acci denis Make sure that a separate power supply circuit is provided for this unit and that all elec trical work is carried out by qualified personnel according to local laws and regulations and this installation m
29. o set a unique address for it Follow the setup procedure described in this chapter Procedure To set the address of an outdoor unit use push buttons provided on the unit s printed cir cuit board The current setting or operating status of an outdoor unit is indicated by the on blink or off of its LEDs Mode indicator LED 8 8 8 8 8 8 878 H1P H2P H3P H4P H5P H6P H7P H8P BS1 BS2 BS3 BS4 BS5 B Microcomputer operation monitor Mode switch 1 Press the BS1 button for 5 seconds or more The H1P LED lights up 2 Press the BS2 button 13 times This causes each LED on the printed circuit board to be in the following state which indicates that you are in the address setup mode H1P H2P H3P H4P H5P H6P H7P OL e o o e o O On Off 3 Press the BS3 button You can now find out the current address setting by the blinking LED 4 Press the BS2 to change to the desired address The default setting is O 5 Press the BS3 twice to fix the address setting 6 Press the BS1 button once to return to the normal mode Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor D 5 18 2011 12 05 00 PM n 6 1 6 2 English 01_EN_3P291714 3 indd 31 Quick Operation Guide Viewing target area and management point information i
30. ote controller eee eeeeeeeeeeeeneeeeeeeeneeeeeeeeeaeeeeeeeetaeeeeeeeaes 25 4 1 2 Procedure for a navigation remote controller 27 4 1 3 Setting an unique address to each unit when power distribution is enabled 29 4 Installation Manual 3P291714 3 English 01_EN_3P291714 3 indd 4 DCM601A52 iTM plus adaptor D 5 18 2011 12 04 54 PM n 5 Outdoor Unit Address Setup 5 1 6 Quick Operation Guide 6 1 6 2 6 3 English 01_EN_3P291714 3 indd 5 Viewing target areas and management points Starting stopping an area or management point Viewing target area and management point information in list format Installation Manual 3P291714 3 DCM601A52 iTM plus adaptor 1 1 a 01_EN_3P291714 3 indd 6 Before Installation Before you start installing the iTM plus adaptor complete the following checks e Check that the iTM plus adaptor comes with all accessories e Understand where the terminals and switches of the iTM plus adaptor are located e Make sure that an appropriate space for installing the iTM plus adaptor is available Checking that all accessories are included Based on the following accessory list check that all accessories for the iTM plus adaptor are included Should there be any missing or defective parts contact your dealer lt Accessories included with iTM plus adaptor gt a 1 iTM plus ada
31. oups 128 indoor units can be connected A maximum of 64 indoor units can be connected when power distribution is enabled Installation Manual 3P291714 3 15 DCM601A52 iTM plus adaptor D 5 18 2011 12 04 56 PM n 2 2 2 Cable specifica tions Precautions 2 2 3 16 01_EN_3P291714 3 indd 16 NOTE m What s a remote controller group A single remote controller can simultaneously control a maximum of 16 indoor units This capability is referred to as group control A remote controller group is a group of indoor units controlled under the same remote controller Conceptual drawing of a remote controller group A Fi F2 P1 P2 Fi F2 Be F1 F2 Ea Fi F2 be a A Max 16 units Requirements that must be met e Cable type 2 core vinyl insulated vinyl sheathed cable vinyl cabtyre cable or 2 core shielded cable e Core thickness 0 75mm 1 25mm e Terminal treatment Use a round crimp type terminal M3 with insulating sleeve e Do not use multicore cables with three or more cores e When using a shielded cable connect only one end of each steel wire to the ground e Keep the DIII NET communication wiring at least 50 mm away from power supply wir ing e The maximum wire distance must be kept to 1000 meters or less The total wire length must be limited to 2000 meters except when using a shielded cable whose
32. ptor body 1 pc b 1 Round head wood screw 3 5x16 4 pcs c 1 Cable tie 1 pc d 1 Installation manual This manual 1 pc d 2 Manual CD 1 pc 00 gt Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor D 5 18 2011 12 04 54 PM n 1 2 1 3 1 3 1 English 01_EN_3P291714 3 indd 7 Understanding external dimensions e iTM plus adaptor body 136mm 149 2mm Understanding where terminals are located Understand the arrangement of terminals and switches on the unit and draw up an effi cient work plan For connection details including the cable type terminal size and wiring precautions refer to 2 Connection Front face of iTM plus adaptor All the terminals used during installation are located on the front face of the iTM plus adaptor Note that only the power terminals are covered with a terminal cover for safety You can remove this cover by loosening a single screw In addition to these terminals several switches and LEDs are also located on the front face of the iTM plus adaptor Installation Manual 3P291714 3 7 DCM601A52 iTM plus adaptor D 5 18 2011 12 04 54 PM 01_EN_3P291714 3 indd 8 lt Front face of iTM plus adaptor gt
33. sions in the air or where volatile flammables such as paint thinner or gasoline are handled Operating the unit in such conditions may result in fire 4 High temperature area or directly flamed point Abnormal heat build up or firing may be caused 5 Moist area or place where may be exposed to water If water enters inside the unit an electric shock and malfunction may be caused English Installation Manual 3P291714 3 3 DCM601A52 iTM plus adaptor _____ 01_EN_3P291714 3 indd 3 D 5 18 2011 12 04 54 PM n Contents 1 Before Installation sscccsrornnnanensessennnnnnnrrersnsennueaantannssnsnsn nenennns 6 1 1 Checking that all accessories are included 6 1 2 Understanding external dimensions 0 0 0 0 eee eect eee etee eter eettae eee eeeeaeeeeeeenaeeeeeeenaeeeeeeeneeeeess 7 1 3 Understanding where terminals are located ccccceeeeenceeeeeseeceeeeeteeeeeeeesneeeeeeeeseeeeeeneneeeneeeees 7 1 3 1 Front face of iTM plus adaptor eee eee e ence eee eeeee eset eeanee eee teaeeeeeeeeeeeeeetenaeeeeeeeeaaees 7 1 4 Determining installation place generee A E 9 1 4 1 Installation place and Mounting direction 2 0 eee inusisa aa 9 1 4 2 Required Space iii 9 1 4 3 Environmental conditions ss 10 2 Connection naine annee Eana a aa N E aE aE a 11 2 1 Connecting intelligent Touch Manager ii 12 2 1 1 Terminals location and conceptual connection diagram ceeeeeeeeeeneeeeeeeetteeeeeeeeaes 12 2 1 2 Requirements that must be
34. taneous contact is used for triggering an emergency stop use one that has an energization time of 200 ms or more e Do not clamp the cables with high current lines such as a power cable 18 Installation Manual 3P291714 3 English DCM601A52 iTM plus adaptor 01 _EN_3P291714 3 indd 18 D 5 18 2011 12 04 56 PM 2 4 2 4 1 English 01_EN_3P291714 3 indd 19 Connecting power supply Connect the iTM plus adaptor to an AC power supply WARNING an electric shock The following procedures must be carried out with the power supply shut off Do not turn the power supply on until all connections are made Doing so may cause Terminals location and conceptual connection diagram For safety reasons power connection terminals are covered with a protective cover Remove this cover before you start connecting the power supply You can do so by loosening a single screw using a Phil lips screwdriver The terminal cover must be replaced where it was before when you finish connecting the power supply lt Removing terminal cover gt g o gt xe ZA f f Next connect the power supply to the three terminals L Live N Neutral and ground in the POWER section Be sure to ground the ground terminal Remember to secure the power cables to the blue resin cable mount with cable ties when power connections are made lt Connecting power supply gt