Home
GSM-21T
Contents
1. Others Unknown code X zone or user number Programming mode 1 Disconnect the GSM module from the power supply both mains supply and 12V battery if it was previously loaded 2 Disconnect the GSM phone from the GSM module JR1 3 Deactivate the PIN code according to the phone user manual 4 Enter the GSM phone programming mode Messages menu then Send new Example for Ericsson A2628s Buttons and gt are for scrolling command menus and sub menus on the same level Button Yes is used for entering the submenus of the current command menu Button No is used to exit the current menu and return to the main menu Keys Yes and No are for positive or negative answers to current questions that the GSM phone user is asked press keys C then Yes to unlock the keypad if there is the case press key twice Messages menu shows up 19 7 19 press key Send new menu shows up press key Yes Send new submenu shows up 11 5 in this case a configuration SMS will be created having the next structure enter indicative CF1 comma code generated by phone line loss 2 HEX digits comma code generated by phone line restoring 2 HEX digits comma code generated by activation ground connecting of the first communicator input 2 HEX digits comma code generated by deactivation of t
2. Messages menu shows up press key Yes Select option Send new Press key Yes edit the configuration message and press key Yes if option Message type shows up select text and press key Yes select activated for option Reply and press key Yes press No for option Number press No until reaching the main menu 7 Connect the phone to the GSM module JR1 8 Mount a by pass wire between the IN1 and ground 9 Power on the GSM module 220Vac mains and 12V battery 10 After the green LED turned off twice stop powering the module 11 Remove the by pass wire the module is ready to operate GSM phone from Ericsson family in accordance to the technical specifications is not for delivery purposes It can be acquired from the GSM network distributors agreed by the beneficiary Each user can choose the favorite type of subscription and GSM network 27 29 Calimachi St 72266 Bucharest AC Tel 021 204 47 00 Fax 021 242 20 30 a ZZ E mail sales roel ro www roel ro Romano Electro In l sa PE sj life 14
3. i core GSM communicator for Ericsson 2628 Hook up Installation and Programming Manual Doc 10112 septembrie 2002 version 1 0 Contents GENERAL FEATURES asi sscasyavieresnudon aoe eseder ais eeeaseied Reia Applications of the GSM 21T communicator cccceeeeeeeeeeeeeeeeees Functions of GSM 21T communicator ccccccccccceceeeeeeeeeeeeeeeeseeeeees Functioning modes of the GSM 21T communicatotr ccceeeeseeeeees TECHNIC Aly PEAR ES ses essestanosinias eects aretsvaraetennseeedeaneee DTMF communication formats of the alarm control panel Available inputs and Outputs 200 0 ceccccccccccccccceeseseececceeeceaeeeeeeeeeseeeenaas PUnC HONING dicato Sacce ora ieee Nene oe eae eee OMS MEAP ONS iio cece sutcoscecursaiasoutcsonedes A A T GSM network specifications wcacectssseatidivwetessiendsemaataayaaswikeniiwdeetss INSTALLATION renere r E rS 7 GSM r iG taal e teacateavedsleended iehoteesadetnanieinawcbavenielatehotenetsess FSA FPA MG BE programini NS eae to oS eee eT GENERAL FEATURES GSM 21T is a GSM communicator mounted in a metallic case Inside the case there is a 220V transformer a back up battery and a compartment where the mobile phone from Ericsson family see Usable GSM phones is to be placed allowing the antenna to get out of the case GSM 21T communicator can be used as an accessory for a burglary control panel with digital communicator or as a stand alone alarm uni
4. For the owner s phones use MOB indicative followed by a figure from 1 to 4 As for the monitoring station phone numbers the figure makes the difference among the 4 phone numbers which can be associated to the owner Example if the second mobile phone number of the beneficiary is to be programmed enter name MOB2 followed by the number of the respective phone at the name section in the phone book Name MOB2 phone number 0721567829 If the control panel is partitioned then the monitoring station phone numbers 1 and 3 as well as those of the alarm system owner are reserved for the first partition while 2 and 4 are reserved for the second one Events occurred in the first partition are transmitted only to numbers 1 and 3 while events occurred in the second one are transmitted to numbers 2 and 4 Events occurred at the communicator are transmitted to all numbers IDs are also set in the phone book For the first partition the name begins with PNR and continues with the account number Example PNR3421 where 3421 is the account number of the corresponding partition being set in the burglary control panel For the phone number corresponding to that name add 6 zeros Name PNR3421 Number 000000 For the second partition the name begins with SNR and continues with the account number Example SNR9832 where 9832 is the account number of the second partition being set in the burglary control panel For the phone number corresponding to that
5. longer assured The mobile phone of the communicator is recommended to be used for this application exclusively Its client number must not be disclosed as someone could call it However if the phone must be used for an emergency the phone should be programmed as the client number is not displayed on the called phone display The GSM hardware was designed to allow more developed versions of the software free of charge upgrades in the future These versions will allow implementations of automation commands on the present hardware 6 outputs at the most and remote process supervision 6 inputs at the most The present software version of the GSM communicator allow its usage together with Xwatch DPC 08 monitoring station produced by Romano Electro Int l and SMS message transmission on the mobile phone of the burglary control panel protected objective s owner INSTALLATION The GSM 21T will be connected between the burglary control panel and the GSM phone GSM 21T installation The connectors order from left to right is the next JR1 6 pin connector the cable is connected to the GSM phone DIG_COMM must be connected to the phone line connectors of the burglary control panel 16VAC must be connected to the secondary winding of the power transformer LINE must be connected to the phone dose TRBL output it goes high if telephone line is not OK DO1 DO6 automation outputs upon construction 12VDC 12V
6. name add 6 zeros Name SNR9832 Number 000000 For the communicator the ID is set using the MNR indicative followed by the account number Example MNR5674 where 5674 is the communicator account number Name MNR5674 Number 000000 Events with this ID will be transmitted to all phone numbers in the phone book If messaged are not to be transmitted to certain phone numbers then those numbers will be deleted in phone book If some events are to be transmitted from a single partition onto more phones than those associated to one partition then the same account will be set for both partitions in the phone book on the SIM card Example PNR3490 and SNR3490 Event code programming codes generated for phone line loss and restoring codes generated in order to activate deactivate the communicator s inputs code generated to make the GSM signal weaker code generated for the periodical test periodical test duration in hours Notes 1 SMS messages are implicit and automatically generated Message issuing is not allowed in this software version 2 SMS messages are available only for Ademco Express 4x2 format 3 The meaning of sent codes associated to the events occurred was implemented in this software version of the GSM communicator according to the table below zone user code Event denomination SMS message E9 Restoring Siren restoring FB Trouble Phone line loss EB Restoring Phone line restoring xX
7. generate clear SMS messages Notes In the edit mode digits can be obtained directly by pressing the corresponding keys longer The comma and period can be obtained by successively pressing key 1 Upon editing each key is used for several symbols i e letter C is obtained by successively pressing key 2 for 3 times Press shortly key in order to switch from capital to small letters or vice versa also modifies the last edited character from capital to small letter or vice versa Keys gt and lt are used to move the slide to the right and left within the edited message By long pressing these keys the slide is directly moved to the beginning or end of the edited message Key CLR Clear is used to delete the character on the right or left of the slide 6 Save this SMS with no destination phone number in the phone memory not the card s 13 Example for Ericsson A2628s In the edit mode after the configuration message was edited press key Yes The destination phone number will be answered to with NO If there is the case to modify an existent message answer with key NO to the Store and Erase questions Note There must be only one message stored in the mobile phone that is the configuration SMS message Older messages must be erased press keys C then Yes to unlock the keypad if there is the case press key twice
8. he first communicator input 2 HEX digits comma code generated by activation ground connecting of the second communicator input 2 HEX digits comma code generated by deactivation of the second communicator input 2 HEX digits comma code generated by activation ground connecting of the third communicator input 2 HEX digits comma code generated by deactivation of the third communicator input 2 HEX digits comma code generated by activation ground connecting of the fourth communicator input 2 HEX digits comma code generated by deactivation of the fourth communicator input 2 HEX digits comma code generated by activation ground connecting of the fifth communicator input 2 HEX digits comma code generated by deactivation of the fifth communicator input 2 HEX digits comma code generated by activation ground connecting of the sixth communicator input 2 HEX digits comma code generated by deactivation of the sixth communicator input 2 HEX digits comma code generated by GSM signal weakening 2 HEX digits comma code generated by the periodical test 2 HEX digits comma duration in hours the periodical test is performed at 2 decimal digits period 12 Note all previously defined fields will be filled in the number of commas must be 17 in any circumstance A typical example of a c
9. he phone programming mode These events generated by the GSM communicator are transmitted through GSM irrespective of the phone line status TECHNICAL FEATURES DTMF communication formats of the alarm control panel ADEMCO Express 4x2 Contact ID PID Available inputs and outputs 6 inputs with programmable codes for activation and deactivation 6 open collector outputs used for automations upon construction Functioning indicators The module has got a green signaling LED indicating GSM phone presence and proper functioning Consumption supply voltage mains 220Vac 12V 4A rechargeable battery maximum current consumption 12Vac including GSM phone loading 500mA average current consumption 12Va_ loaded GSM phone 40mA Note The GSM phone connected to the GSM module is loaded from the module GSM network specifications can be used in any GSM authorized network Usable GSM phones Ericsson A2628 A2618 T20 T28 R320 T29 T39 T65 Other technical features average duration of GSM communication 8s active inputs by GND maximum current at open collector outputs 500mA WARNING For this present version the software in the GSM communicator does not allow using the GSM phone connected to the GSM module in function for vocal phone communications Hence if this GSM phone is used simultaneously for conversations the proper functioning of the GSM communicator is no
10. ions of the GSM 21T communicator GSM 21T communicator was designed to be used in one or several situations below an alarm system with a digital communicator can function more securely if a GSM 21T module is added This module notices if the phone line is missing by accident or intentionally from the alarm system takes the control panel s events and drives them to one or several GSM monitoring stations phone line back up Thus the alarm system is never vulnerable and will transmit any event to the monitoring station in real time an objective protected by an alarm system with digital communicator for which a phone line is not available remote villas depots can report system events to one or several monitoring stations up to 4 and intervention for a lower cost compared to the radio monitoring an application for event transmission regarding some inputs status when no alarm system is needed panic buttons etc an application for output remote control using the own mobile phone turning on central heating light etc under construction Note for the first 3 cases the respective events can be transmitted to 4 monitoring station numbers at most and optionally explicit sms messages can be transmitted to 4 phone numbers at most whose owner could be the beneficiary himself The next image describes functions of this communicator Connection of GSM 11T communicator in the alarm system Programmable outputs k k
11. k The phone of the alarm systern s Owner alarm GSM control panel communicator Inputs with programmable codes Phone line from Rom Telecom control panel GSM monitoring station Functions of GSM 21T communicator The digital GSM communicator performs several functions detects loss and restoring of the phone line which the burglary control panel is connected to and forwards these events supervises the phone line in case that one gets faulted the communicator will generate the line tone taking the events occurred at the control panel and retransmitting them through the GSM network in digital format to one or several GSM interface monitoring stations optionally clearly as SMS messages onto a different mobile phone i e on the mobile phone of the burglary control panel protected objective s owner provides 6 individual inputs to which sensors can be connected burglary fire etc allowing the independent usage of the GSM communicator when the burglary control panel is missing transmits a periodical test with a programmable period transmits a code in case of weak GSM signal detects mobile phone shutting down and commands its turning on 4 Functioning modes of the GSM 21T communicator GSM 21T communicator can function in 3 ways it transmits events occurred at the objective protected by the burglary control panel only to one to four GSM monitoring station Xwatch DPC 08 it tra
12. nsmits events occurred at the objective protected by the burglary control panel only as SMS messages to the mobile phone of the objective s owner it transmits events occurred at the objective protected by the burglary control panel both to one to four monitoring station and as SMS messages as well to one to four phones of the objective s owner In order to select the functioning mode define in the phone book on the SIM card the monitoring station and or mobile phone numbers whose owner can be the alarm system beneficiary himself Definitely 4 phone numbers can be configured for the monitoring station phones 1 and 3 corresponding to the first partition while phones 2 and 4 to the second one 4 phone numbers can be similarly configured for the owner as well meaning phones 1 and 3 corresponding to the first partition while phones 2 and 4 to the second one Events generated by the burglary control panel are taken by the communicator only if the ground phone line is cut off or unavailable and retransmitted further on to the stations monitoring the corresponding partition The communicator can transmit explicit SMS text messages to the alarm system owner s phones The events generated by the communicator are phone line loss restoring communicator s local inputs activation deactivation weak GSM signal and periodical test A 4 HEX digit account number should be defined for these events in the phone book on the SIM card according to t
13. onfiguration SMS message CF1 FB EB 00 01 02 03 04 05 06 07 08 09 0B 0C 0D 90 10 Upon phone line loss and phone line restoring respectively the communicator will generate codes FB and EB having the account number specified in the phone book Upon activation deactivation of the 6 inputs of the communicator codes 00 02 04 06 08 OB and 01 03 05 07 09 and OC with account number specified in the phone book Upon GSM signal weakening the interface will transmit code OD settled in the configuration SMS to the monitoring station The interface transmits code 90 for the periodical test The duration for the periodical test performing is 10 hours Note Changing codes associated to events in the configuration SMS will trigger the appropriate interpretation of events associated to these codes For example if the 6th parameter is programmed 38 instead of 00 then upon activation of the first communicator input an Alarm on zone 8 SMS type will be transmitted instead of TRIG1 ON while the monitoring station will consider the event of the same type Any change of the configuration SMS is accompanied by a restart of the GSM module Note Format DTMF 4x2 describes events in such a manner that necessary information is presented by means of 6 HEX digits AAAAEZ where AAAA is the client s account number E is the event code Z is the zone user number For format Ademco PID the interface will not
14. output IN1 IN6 automation inputs Installatin 1 program the GSM phone using the software in case the phone programming kit or the manual according to the section refering to phone programming 2 check if the configuration sms can be read 3 enter a by pass wire between Int 1 and ground in order to reset and reprogram GSM 21 Tmodule 4 connect the cable to the GSM phone and JR1 5 power the module from the Ac power supply or the battery 6 wait until the green LED turns off twice 20 30 seconds 7 cut the GSM 21T module power supply off both from the mains and thee 12V battery 8 remove the by pass wire from between the Int 1 and ground 9 power the GSM 21T module again After the green LED turned off twice the module is ready to work Note If the green LED does not turn on or the GSM communicator is supposed not to function do the next 1 shut the GSM module down both mains supply and 12V battery and disconnect the GSM phone JR1 shut the GSM phone down wait for at least 10 seconds restart the GSM phone connect the phone to the GSM module connector JR1 and power on the GSM module The green LED should turn on After the green LED turned off twice the module is ready to work O A WwW N STATUS LED 12Vdc D01 D06 OUTPUTS TRBL TROUBLE LINE to the phone dose 16Vac to the secondary winding of the power transformer DIG_COMM to the
15. phone line connectors of the burglary control panel Lu pa H GSM phone connection Connection Scheme for GSM 21T GSM 21T programming Note Before programming the GSM module program the burglary control panel to phone line transmit events in DTMF formats Ademco Express or Ademco PID to the monitoring station Using the GSM phone keypad all module parameters will be programmed these being 4 monitoring station numbers 4 mobile phone numbers for explicit SMSs for the data format Ademco Express 4x2 Ids of the two partitions and the communicator ID Codes of events monitored by the GSM communicator Phone number and ID programming Phone numbers are programmed in the phone book on the SIM card Before starting phone number programming track if there are one of the following numbers in the book DSP1 DSP2 DSP3 DSP4 MOB1 MOB2 MOB3 MOB4 PNR SNR MNR In case one of these numbers exists it will be deleted as it will be reprogrammed later Monitoring station numbers have the DSP indicative next to the name followed by a figure from 1 to 4 thus making the difference between the 4 phone numbers associated to one or several monitoring stations As an example the third monitoring station number is thus set Name DSP3 phone number 0723471891 For option name set DSP3 For option phone number set the mobile phone number where information must be transmitted to
16. t GSM 21T communicator can be connected to a burglary control panel as backup for the telephone line in case it is faulted or directly in case of missing telephone line Thus the communicator provides a higher security level for objectives protected by burglary alarm systems In case the control panel transmits events in DTMF formats the GSM module receives and codifies them while the GSM phone transmits them to the GSM monitoring station which must have a GSM interface This GSM interface decodes the signal transmitted by the communicator GSM phone The GSM interface is produced by Romano Electro Int Company as an accessory for the Xwatch DPC 08 monitoring station The owner of the burglary alarm system can optionally get SMS formatted event description on his her own GSM phone The communicator transmits the events to at most 4 monitoring station numbers and it can additionally send the text messages to other 4 phone numbers GSM 21T communicator can be used in all GSM telephone networks selected through the acquired SIM card GSM 21T communicator is totally compatible with the burglary control panels in Cerber XL Paradox families etc Parameter programming is performed by means of the GSM phone In case the installer acquires the programming kit PC cable and a CD containing the installation kit the SetConfig software running under Windows 95 can be used for a smart programming of the module parameters Applicat
Download Pdf Manuals