Home

USER MANUAL

image

Contents

1. This warranty gives you specific legal rights and you may also have other rights which vary from place to place NOTE All products returned to Kramer for service must have prior approval This may be obtained from your dealer This equipment has been tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Residential commercial and light industry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and light industry environment CFR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION E Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment E Use the supplied DC power supply to feed power to the machine E Please use recommended interconnection cables to connect the machine to other components FCC and CE approved using STP cable for twisted pair products For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com Disconnect the unit from the powe
2. in Central Europe and France you should order country specific sockets instead Not compatible with South African plugs USA 100 240V AC 50 60Hz 5A nan perp t Germany and EU 100 240V AC 50 60Hz 5A poem smn perp tt Belgium and France 100 240V AC 50 60Hz 5A Pere smn a t South Africa 100 240V AC 50 60Hz 5A pees wna persone oa Australia 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Legrand manufactured 100 240V AC 50 60Hz 5A sockets for various Maximum 5A per power outlet countries Mosaic Series perp FUSE RATING T 6 3A 250V OPERATING TEMPERATURE 5 to 45 Deg Centigrade RANGE OPERATING HUMIDITY 10 to 90 RHL non condensing RANGE STORAGE TEMPERATURE 20 to 70Deg C RANGE STORAGE HUMIDITY RANGE 5 to 95 RHL non condensing DIMENSIONS WEIGHT ACCESSORIES OPTIONS 250 2mm x 137 5mm x 65mm 9 85 x 5 41 x 2 56 W D H 0 4kg 0 88lbs approx Power cord self locking ties wood screws Passive wall plates and interfaces power socket kits power cord Specifications are subject to change without notice at http www kramerelectronics com LIMITED WARRANTY We warrant this product free from defects in material and workmanship under the following terms HOWLONGIS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase WHOIS PROTECTED Only the first purchase customer may enforce this warranty WHAT IS COVERED AND WHAT
3. IS NOT COVERED Except as below this warranty covers all defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by us or which is not purchased from an authorized Kramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the Web site www kramerelectronics com 2 Any product on which the serial number has been defaced modified or removed or on which the WARRANTY VOID IF TAMPERED sticker has been torn reattached removed or otherwise interfered with 3 Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not authorized by Kramer iv Any shipment of the product claims must be presented to the carrier v Removal orinstallation of the product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removalor installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming T
4. KRAMER ELECTRONICS LTD USER MANUAL MODEL MODULAR UTBUS 1 Under the Table Connection Bus P N 2900 3000 76 Rev 1 UTBUS 1 Quick Start Guide This page guides you through a basic installation and first time use of your UTBUS 1 For more detailed information see the UTBUS 1 user manual You can download the latest manual at http www kramerelectronics com Step 1 Check what s in the box A UTBUS 1 Under the Table Connection Bus A 1 Quick start guide 4 mounting wood screws 1 User Manual 6 self locking ties Step 2 Connect the wall plate items Remove Screw Remove Blank Plate Remove Screw E M I a aa ais Rep S Step 3 Install the cables Connect the cables to the inside of the UTBUS 1 and secure them with the self locking ties Step 4 Install the UTBUS 1 to the table Replace Screw Contents 1 Introduction 2 Getting Started 2 1 Achieving the Best Performance 2 2 Glossary 3 Overview 4 Your UTBUS 1 Enclosure 4 1 Power Socket Options 4 2 Power Cord Options 5 Installing the UTBUS 1 5 1 Installing the Required Wall Plate Inserts 5 2 Installing the Cables 5 3 Connect the Kramer TOOL or Pico TOOL Optional 5 4 Securing the UTBUS 1 Enclosure to the Table 6 Technical Specifications of the Assembled UTBUS 1 Figures Figure 1 UTBUS 1 under a Table Figure 2 UTBUS 1 Under the Table Connection Bus Figure 3 Installing a Kramer TOOL Figure 4 Securing the UTBUS 1
5. gh the tie holes to secure the cables to the inside walls of the enclosure Connect the Kramer TOOL or Pico TOOL Optional You can install a Kramer TOOL or Pico TOOL as illustrated in the example in Figure 3 To connect the Kramer TOOL to the UTBUS 1 1 Connect the mounting brackets to the Kramer TOOL as described in the Bracket Installation Kit Instructions 2 Insert the four 4x3 8 screws into the four TOOL mounting holes and fasten the Kramer TOOL to the inside floor of the UTBUS 1 Figure 3 Installing a Kramer TOOL UTBUS 1 Installing the UTBUS 1 5 4 Securing the UTBUS 1 Enclosure to the Table To install the UTBUS 1 underneath the table as illustrated in Figure 4 do the following 1 Place the unit to the underside of the table and mark the correct location 2 Insert the four M4 2X16 wood screws into the four rim screw holes and fix the UTBUS 1 to the table Figure 4 Securing the UTBUS 1 to the Underneath of the Table The UTBUS 1 is ready for use 6 Technical Specifications of the Assembled UTBUS 1 POWER SOURCE AC power limits Power Socket Assemblies Universal 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Fully compatible with power plugs in the UK India Italy and Denmark as well as with the 2 prong Europlug Partially compatible if the polarity is reversed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs
6. hese costs are the responsibility of the Kramer dealer from whom the product was purchased 3 Shipping charges HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized Kramer service center 2 Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OF DAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss of time commercial loss or 2 Any other damages whether incidental consequential or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you
7. ou can order any of the following power cords to use with the UTBUS 1 Power Cord Type Description P N 220V Israel 220V Israel AC POWER CORD 6ft UK 250V UTBUS 1 Your UTBUS 1 Enclosure 5 Installing the UTBUS 1 This section describes how to e Install the required wall plate insert items see Section 5 1 e Install the cables see Section 5 2 e Connect the Kramer TOOL or Pico TOOL optional see Section 5 3 e Secure the unit under the table see Section 5 4 5 1 Installing the Required Wall Plate Inserts By default the mounting surface includes a power socket opening and four blank plates for optional video audio and network connectors Each blank plate can be removed and replaced with a Kramer passive wall plate insert or connector module for interfacing A V type signals if required To install a wall plate insert or connector module do the following Remove Screw Remove Blank Plate 1 Unscrew the two screws that attach the blank plate to the connecting surface and remove the blank plate save the two screws 2 Place the required wall plate insert item over the opening H L AYM UTBUS 1 Installing the UTBUS 1 9 2 5 3 3 Reinsert the two screws to affix the wall plate insert in position and tighten them Replace Screw Installing the Cables To install the cables do the following 1 Connect the cables to the inside of the unit 2 Insert the self locking ties throu
8. r SAFETY WARNING supply before opening and servicing
9. rictions in Section 6 or Legrand type power sockets for use with Legrand s white Mosaic series only Order the power sockets separately from Kramer Electronics e Lets you install a Kramer TOOL or Pico TOOL inside the body of the UTBUS 1 Figure 1 UTBUS 1 under a Table 4 Your UTBUS 1 Enclosure VS ZH 09 05 OVA OF2 001 O OO OO OO O 0 e e Feature Function 1 Blank Plates Four blank covers that can be replaced with wall plate inserts as required see Section 5 1 2 Computer Graphics 15 pin For pass through computer graphics signals HD female female Connector 3 5mm stereo Audio For pass through audio signals Female Female Connector 4 Universal Power Socket Suitable for international power requirements available with other types of power sockets For mounting under the table TOOL Mounting Holes 8 Screw in the appropriate holes to install a Kramer TOOL or Pico TOOL 7 Tie Holes 12 Insert the self locking tie through the holes to fix the pass through cables to the inside walls of the UTBUS 1 Rim Screw Holes 4 For fixing the UTBUS 1 under the table including two open screw holes 4 1 Power Socket Options A choice of one or more power sockets per inner frame is available in several versions including power sockets for the USA Germany the Europlug Belgium France Italy and Australia A Universal socket for general use is also available see the compatibilit
10. to check if firmware upgrades are available where appropriate 2 1 Achieving the Best Performance To achieve the best performance e Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position your Kramer UTBUS 1 away from moisture excessive sunlight and dust 2 2 Glossary Legrand socket For use with Legrand s white Mosaic series only Universal socket The Universal socket fits almost all power cords worldwide The insert is fitted in the inner frame Go to our Web site to check for a variety of single and dual sized inserts Overview The UTBUS 1 is a furniture mounted connection bus that is easily installed underneath a wooden table or podium top The unit is sturdy cost effective and easy to install In addition the UTBUS 1 e Includes two permanent components suitable for connecting a PC one 15 pin HD connector and one stereo audio 3 5mm mini jack e ls modular in design letting you install up to four wall plate inserts according to your requirements e Power socket openings that are suitable for any of the following power sockets for the USA Germany the Europlug Belgium France Italy Australia Universal for use anywhere see compatibility rest
11. to the Underneath of the Table _ _ OOONN OORA WO NNN OO RW Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Products Thank you for purchasing the Kramer UTBUS 1 which is ideal for boardrooms conference and training rooms 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performance high resolution cables Go to http www kramerelectronics com to check for up to date user manuals a complete list of Kramer wall plates and module connectors application programs and
12. y restrictions in the table below as well as Legrand manufactured sockets the Mosaic series only which comes in white that are suitable for various countries Single Power Socket Assemblies Power Specs Universal TBUS PS UNIV 80 000899 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Fully compatible with power plugs in the UK India Italy and Denmark as well as with the 2 prong Europlug Partially compatible if the polarity is reversed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs in Central Europe and France you should order country specific sockets instead Not compatible with South African plugs USA TBUS PS US 80 000999 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Germany and EU TBUS PS DE 80 001299 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Belgium and France TBUS PS FR 80 001399 100 240V AC 50 60Hz 5A Maximum 5A per power outlet TBUS PS ITALY 80 001499 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Your UTBUS 1 Enclosure Single Power Socket Assemblies Power Specs Australia i TBUS PS AUS 80 001599 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Legrand manufactured sockets for various TBUS PS LEGRAND 80 001799 countries For example the Legrand assembly with a UK power socket 100 240V AC 50 60Hz 5A Maximum 5A per power outlet 4 2 Power Cord Options Y

Download Pdf Manuals

image

Related Search

Related Contents

BEDIENELEMENTE - Harley  edison meter catalog - Everchamp Tools And Equipment  MAPublisher 8.0 User Guide  MVI94-DNP User Manual  Installation and Operation Manual  Samsung TC241W User Manual  Samsung SP-F011GR User Manual  Server/Loader User Manual  none 664X Instructions / Assembly  3. Drücken Sie die  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.