Home

1500eXD/1500eXDPNK dialSpeed™ Instructions

image

Contents

1. 1500eXD 1500eXDPNK dialSpeed Instructions video at www masterlock com TO REMOVE THE PADLOCK FROM THE PACKAGE Pua oo mh z tki e 1 On back of card cut through 2 Cut through tabs at 3 Fold down bottom of drawer 4 Insert thumb into drawer and perforated tabs across the 4 corners on bottom firmly press down on center bottom of package of package black vertical tab il ig TIGA Ti on bafian Krei peice ee05 Rae Primary Code ra fasten Code primaire C digo Principal titel lit E 5 Pull plastic drawer 6 Remove the folded 7 The Primary Code for your lock appears on the user manual as out of the package user manual a series of 5 up down left right arrows like the example above Enter this code on the keypad and pull down on the lock to remove it from the package Store your codes at masterlockvault com Additional instructional videos can be found at www masterlock com QUICK START GUIDE 1 OPEN THE LOCK the first time with the factory set PRIMARY CODE at top of user manual by pressing the 4 corresponding arrow buttons in the sequence shown Do not pull on the shackle when entering the code 2 When the center button lights green open the lock within 5 seconds or it will relock NOTE You can use the PRIMARY CODE as your everyday code or you can change it HOW TO CHANGE THE PRIMARY CODE IMPORTANT READ THOROUGHLY Steps must be performed within 5 seco
2. e Center button flashes red 6 times then sleep mode Arrow Position Deletion Failed Primary After the UP position arrow is selected for deletion Code Center button white Awaiting New Code Entry After center button pressed to enter new code Center button lights white and arrows flash with each press Code Entry During new code entry Center button fades in and out white in 1 second Repeats until any but Awaiting Code Confirmation Waiting for code confirmation entry ton is pressed or timeout is reached Center button green Selected arrow flashes 3 times Arrows with stored Code Accepted When confirmation code matches initial code codes light for 1 second then sleep mode Center button flashes magenta 6 times then sleep mode Code Rejected Invalid When new code is invalid Center button flashes red 3 times then sleep mode Code Rejected Does Not Match When confirmation code does not match initial code This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class B digital apparatus complies with Canadian ICES 003
3. ld the Center Button While continuing to press the Center Button once the arrows fade press the first position in the Code and then release both buttons Continue entering the rest of the code e Total access and programming control Guest Codes o Up to 3 Guest Codes can be set by Primary Code user or Backup Master Code user o No Guest Codes are factory set e Can be stored at the RIGHT DOWN or LEFT arrow positions e No programming control e Must be 4 12 positions in length e For greater security use a longer code with multiple directions NOTE To safeguard programming access for the Primary Code user a Guest Code cannot match or start with the same sequence of the current Primary Code i e if Primary Code is UP DOWN LEFT RIGHT a Guest Code cannot exactly match or start with UP DOWN LEFT RIGHT LOCK STATUS The center button and arrows light to indicate lock status during operation and programming See the LED Display Chart below or www masterlock com for additional information HOW TO OPEN THE LOCK 1 Enter a code by pressing the corresponding arrows Do not pull on the shackle during code entry e All arrows light blue when any arrow is pressed The center button lights blue during code entry If the buttons do not light or if the center button flashes yellow during code entry the battery needs to be replaced e To clear the code entry at any time press the center button Re enter the code from the beginning e Af
4. n step 8 to confirm code 11 Press the center button 12 Repeat steps 2 11 to program additional codes 13 Save your codes below or store them safely at www masterlockvault com HOW TO CHANGE THE BATTERY 1 Unlock the lock and pull the shackle up 2 Pull out the battery drawer and remove the old battery Fig B 3 Install a new CR2032 battery with the positive side facing the cutout in the drawer down 4 Close the battery drawer Fig B Jump Slot Fente de saut Ranura de salto HOW TO USE THE BATTERY JUMP SLOT If battery voltage is insufficient to unlock the lock pull out the battery drawer to expose the battery jump Slot Fig C Do not force the drawer open further It will not extend fully with the lock in the locked position Hold a new CR2032 battery in the jump slot with positive side of battery facing toward the lock face and start at step 1 above Program mode cannot be accessed when the lock is powered by a battery in the jump slot Fig C GENERAL OPERATION LED DISPLAY CHART Arrows and center button on for 1 second Wake Up When in locked sleep mode and center button is pressed First arrow button pressed counts towards code entry Center button lights blue and arrows flash with each press Code Entry When in locked sleep mode and any arrow button is pressed or during code entry to unlock Center button green for 1 second Arrows rotate clockwise twice After valid code is accep
5. nds of each other or lock will time out and go into sleep mode 1 With the lock open press and hold center button for 2 seconds Center button will light white indicating the lock is in program mode The UP arrow will light indicating a Primary Code is stored there SEN 2 Press the UP arrow The UP arrow is the only position in which you can program and store the Primary Code 3 Press the center button The UP arrow will blink twice indicating the PRIMARY CODE is ready to be changed 4 Enter a new code as a sequence of arrows letters or numbers by pressing the corresponding buttons The sequence must be at least 4 and no more than 12 positions in length 5 Press the center button It will flash white 6 Re enter the code entered in step 4 to confirm 7 Press the center button It will light green to indicate you have successfully changed the PRIMARY CODE Store your code at www masterlockvault com CODE TYPES Primary Code Factory set code as shown at top of user manual e Stored at the UP arrow position e Can be changed but not deleted e Total access and programming control e Must be 4 12 positions in length e For greater security use a longer code with multiple directions Backup Master Code e Visit masterlockvault com and enter Vault Product Code shown at top right of user manual e Factory set code unique to this lock cannot be changed or deleted e When entering your Backup Master Code press and ho
6. ted shackle can be pulled open Center button blue Arrows flash twice After center button is pressed to clear a code entry Center button flashes red 3 times After 12 arrow button presses are made Center button green for 1 second Arrows rotate counter clockwise twice After shackle is closed Center button fades in and out red in 1 second then off for 2 seconds Lockout 3 Incorrect Code Entries After 3rd incorrect code entry Pressing center button during code entry to clear Repeats for 1 minute the lock counts as incorrect entry Center button red for 1 second then sleep mode 5 seconds after last button press in locked mode 5 second time out no lights on Time Out Lock Not Opened 5 seconds after unlocking without raising the shackle Lock relocks Center button flashes yellow for 4 seconds Low Battery After first button press from locked sleep mode if battery voltage low PROGRAM MODE LED DISPLAY CHART Center button white Each arrow with a stored code lights until button is Stored Code Positions After pressing center button 2 seconds to enter Program Mode pressed Center button white Selected arrow position flashes twice then all ar Arrow Position Selection After pressing an arrow followed by the center button rows off Center button green Selected arrow flashes 3 times Arrows with stored Arrow Position Deletion After pressing and holding the selected arrow position for 5 seconds codes light for 1 second then sleep mod
7. ter three consecutive incorrect code entry attempts the lock times out and center button fades in and out red for one minute e When the proper code is entered the center button lights green and the arrows light clockwise twice 2 After the center button lights green open the lock within 5 seconds or lock will relock HOW TO ADD CHANGE OR DELETE CODES IMPORTANT Steps must be performed within 5 seconds of each other or lock will time out and go into sleep mode Primary Code is always stored in the UP arrow position and can only be changed not deleted Guest Codes can Fig A only be stored in the RIGHT DOWN or LEFT arrow positions and can be changed or deleted Fig A 1 Open the lock using the Primary or Backup Master Code 2 Press and hold the center button for 2 seconds Center button lights white indicating program mode 3 Each arrow position with a stored code lights blue 4 Press the arrow where a new code will be stored or an existing code will be changed or deleted 5 Press the center button The selected arrow from step 4 blinks twice 6 If adding or changing a code If deleting a Guest Code Vv 7 Select a new code between 4 12 positions in length Press and hold the selected arrow for 5 seconds until center using directions letters or numbers Fig A button lights green Code deletion is complete 8 Enter that code by pressing the corresponding arrows 9 Press the center button 10 Re enter the code entered i

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisation : M  Explosion Protection  Ventless Ethanol Fireplace User`s Manual Installation  Cond Gén 1 3009  AWモルタル - ショーボンド化学  MODELES TCM (PRESENTOIR POLYVALENT)  Canon EOS 350D 18-55 Kit  平成26年3月号  Operation Manual - Scandec Systemer  Apple ZM034-4941-A User's Manual  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.