Home

User Manual for CORDON

image

Contents

1. The Russian Federation 124489 Tel 7 495 638 88 00 7 499 940 95 75 Cell 7 903 530 10 01 7 909 638 88 00 Fax 7 499 735 04 91 E mail support ts market com www ts market com 16
2. Producer reserves the right to make changes to the device design without notice which does not worsen its technical characteristics CORDON s appearance Telescopic antenna Sensitivity adjusting knob ON OFF and volume knob Antenna jack Display Button for measur ing signal level and frequency in microphone Button for switch eee meee ing operation modes Button for switch ing frequency range Backlight ON OFF button Pic 1 Controls and appearance of the CORDON field analyzer Display Indicator of Operation mode frequency Indicator range Signal fred Signal level Sensitivity bar Signal graph level bar graph Pic 2 Display of the CORDON field analyzer On the upper side of the device are VOL ON OFF and volume knob SENS sensitivity adjusting knob ANT antenna jack On the side of the device are see pic 3 Network adapter charger jack Headphones jack Headphones jack AC DC adapter charger jack Pic 3 Jacks for headphones and AC DC adapter On the backside there are Built in speaker Batteries compartment cover Operation Preparation for operation includes charging batteries and connecting antenna to the device e To start operation turn switch on the VOL knob The device automatically enters the search mode in the 50 800 MHz frequency range LOW frequency range Use telescopic
3. a wide band receiver designed for search and location of low power sources of electromagnetic radiation in 50 8000 MHz frequency range CORDON allows not only detecting operating 4 transmitter illegally installed in premises but also measuring its frequency and evaluating level of electromagnetic radiation in place of reception The device identifies mobile devices operating on the following standards EGSM900 GSM1800 DECT Bluetooth amp IEEE802 11b g Wi Fi also localize devices which use channels of mobile communication for information transfer Technical Characteristics Operating frequency range MHz 50 8000 Range of input signal measurement dB not less than 55 Sensitivity at measuring signal level search mode mV not worse than 50 4000 MHz 4000 8000 MHz Sensitivity at measuring signal frequencies in frequency ranges mV not worse than 50 800 MHz 5 800 4000 MHz 15 4000 8000 MHz 20 D Current consumption mA no more than at search mode 150 at mic excitation effect mode 350 Power supply voltage built in battery V 4 8 Sensitivity of identification channel of mobile communications signals not worse than mV 5 Time of continuous operation from built in batteries not less than hour at search mode 5 at mic excitation effect mode 2 Charging time hour 6 Dimensions without antenna mm 179 x 67 x 30 Weight kg 0 35 The
4. CORDON Electromagnetic field analyzer OPERATION MANUAL Version March 2013 TS Market Contents Introduchon 3 Pr cautions rsin nen 3 Description and specifications 4 Overlook Ge 4 Technical Characteristics 5 CORDON s appearance 7 ONS DAY ninnaa 8 Operation 10 Search mode A 10 e ue 12 Power supply nessis 13 ID e GE 14 SPORE arene oe 14 Transportation kreier 15 CORDON Electromagnetic field analyzer Introduction User manual for CORDON electromagnetic field analyzer It is recommended to read this Manual carefully before operating the device Precautions Prevent the device from water and dust Do not place the device near heating appliances Do not leave the device in places where temperature can exceed 60 C for example under direct sunlight Do not place the device on vibrating surfaces Avoid strong electrostatic environment Do not touch metal constructions PC casings window curtains with the device antenna Do not open the device case Do not let foreign objects inside the device case When unplugging network adapter do not pull by the cable Do not touch network adapter cable with wet hands The device repairs must be done only by the qualified personnel of the Producer Disregard of these requirements deprives the User of the warranty Description and specifications Overlook The CORDON electromagnetic field analyzer is
5. device works in Bluetooth IEEE802 11b g standard in broadband data transfer mode In these cases the display shows absence of signal frequency or abrupt change of signal level When there is powerful source of electromagnetic field electromagnetic radiation capacity is more than 1mW 0dBm beside false response of analyzer is possible But the analyzer is able to detect and locate hidden devices Audio mode Press the MODE button to enter the audio mode microphone excitation mode Set maximum volume by the VOL knob Search for the threat It is possible to measure level and frequency of the signal in this mode To do it press and hold the MEAS button For batteries saving do not hold the button for a long time 12 Power supply As a power supply source rechargeable battery assembly is employed It consists of four Ni MH batteries During operation batteries charge level is displayed as a three segment symbol of a battery When the batteries are fully discharged the display shows LOW POWER In this case it is necessary to charge rechargeable batteries with network adapter charger The adapter 9 V stabilized 0 5 A is employed for charging batteries It is connected to the DC jack During charging the display shows corresponding symbol of charging Time of full charge is 6 8 hours To charge rechargeable batteries use network adapter included in the complete set ONLY Do not use adapter if t
6. here is mechanical damage on case wall plug or lead In box CORDON field analyzer Telescopic antenna for 50 800 MHz frequency range Wideband antenna for 800 8000 MHz frequency range Headphones Network adapter User manual Storage Storage conditions Ambient temperature from 10 C to 50 C Relative humidity 80 by 30 C Air pressure from 630 to 880 millimeters of mercury Absence of acid alkali and admixture vapor in the premises Transportation Transportation of the device should be conducted in a shipping container by any kind of transport provided the protection from atmospheric precipitation When transporting prevents the device from falling and sharp blows they can cause mechanical damage Warranty The manufacturer guarantees no failure operation and all operating characteristics during 1 one year after the date of shipment by the producer provided the customer follows all the rules stipulated in the documentation Mechanical damage deprives the user of the warranty In case the manufacturer is responsible for malfunction or failure of the device it is guaranteed to be fixed or exchanged for free during 30 days after the date of receiving faulty item Warranty does not cover batteries Repairs or replacement of the device in the post warranty period is to be made according to the additional greement TS Market Ltd Building 10 1 Sosnovaya Alleya Zelenograd Moscow
7. rod antenna in this frequency range To make the device enter the 800 8000 MHz frequency range HIGH frequency range press the BAND button and connect wideband antenna to the ANT jack of the device Search mode e Adjust sensitivity level of the device by the SENS knob Recommended level 2 3 clicks per second To adjust clicks volume use the VOL knob e To search for concealed transmitters in premises slowly move the device near places where threats can be placed furniture household items walls etc Search the premises consecutively in both frequency ranges When approaching sources of electromagnetic radiation repetition rate of clicks increases When detecting suspicious source of radiation repetition rate of clicks increases it is necessary to locate the source Measurement of the signal level is made in the 50 8000 MHz frequency range For frequency measurement choose corresponding frequency range by the BAND button When there is movable communication in the search area they are identified Information about communication type is represented on the display When detecting hidden devices which use EGSM900 GSM1800 DECT Bluetooth amp IEEE802 11b g standards of mobile communication liquid crystal display shows type of communication standard The hidden devices can t be located in the following cases 1 two or more devices work simultaneously in the same frequency range 2 when

Download Pdf Manuals

image

Related Search

Related Contents

Curriculum Vitae Europass  Manual de Usuario, Instalación y Configuración  エレベーター [階段室型共同住宅用エレベーター (単体)] 性能表示  VM-DV137 Manual de usuario User Manual Manual de    Polar LOOK Kéo Power  FP1800MBNC Users Manual - Richardson Electronics  Scarica qui il numero della Rivista in PDF!  Samsung RH56J6917SL Manuel de l'utilisateur  NLPプラクティショナーコース “先着12名限定”  