1. 18 months when stored at 4 C 8 C 12 months when stored at room temperature Do not freeze Product use For research use only not intended for diagnostic use EZ PAGE User Manual Getting Started You Will Need EZ PAGE cassette at room temperature EZ PAGE Electrode Cap purchased separately Cat No E303 includes pre installed electrodes and two color coded cables Electrophoresis power supply any power supply can be used Sample loading buffer any sample loading buffer can be used use EZ PAGE Sample Loading Buffer for best results Cat No LB1 Protein molecular weight markers if using protein molecular weight markers are available from EZBiolab Cat No MKPOO1 Preparing Your Samples For best results use sample loading buffer from EZBiolab Other common sample loading buffers such as the Laemmli buffer can also be used Prepare samples according to standard protocols for SDS PAGE EZ PAGE User Manual Opening the EZ PAGE Cassette 1 Remove the seal Place the gel cassette straight up on a lab bench Remove the top seal slowly to avoid spilling the running buffer Remove the top sealing film Top view 2 Open the buffer dam The buffer dam is the top part of the central panel in the running cassette During storage it separates the gel matrix from the cathode buffer The dam needs to be opened to allow the cathode buffer to connect with the top of the gel matrix for electrophoresi
2. EZ PAGE Electrophoresis System USER MANUAL EZBiolab EZ PAGE User Manual Table of Contents Safety Information gjaiccssasvaiassnscsharcirsdausrdnwriadderiennraie Kot opa relin eundi 2 Product Descriptio M TT 2 Product Contents cose maed ia qU OT IR EUR DR TE IDA UC E VER ee 3 Specifications amp Storage Conditions esssss 3 Prod ct USe TETTE 3 Getting Started What You Need sssssssnssssossenessesseeesensreesresesrersereseseernsresseeseeesese 4 Preparing Your Samples eese 4 Preparing for Electrophoresis Opening the EZ PAGE cassette essse ener 5 Loading Your Samples rennen oed ve i ense nen 6 Installing the EZ PAGE Electrode Cap amp Cables 7 Running the EZ PAGE Gel or rone raa Ca i RS Hd Mn HENTAI RUN Ru 8 Retrieving the EZ PAGE Gel sese enn 8 Downstream Processing s sees ennn en ene nenne 9 Disposing of the EZ PAGE Cassette Components 9 Troubleshooting amp Technical Support sees 10 Related Products condere nie octatieenub Fiesta tdem pu debe R ERO ME Um EE 11 Warranty EMEN m 11 EZ PAGE User Manual Safety Information Always wear protective clothing when performing laboratory experiments Wear gloves and eye protection use all proper safety precautions when handling the gels staining destai
3. Z PAGE Electrode Cap and the male end into one of the appropriate slots in your power supply Running the EZ PAGE Gel Run the gels at a constant voltage The recommended voltage is 120 V with a run time of 40 minutes The voltage should not exceed 150 V Retrieving the EZ PAGE Gel 1 When the electrophoresis is complete turn off the power remove the EZ PAGE Electrode Cap and pour out the buffer 2 To release the gel sandwich tip the support bars toward the middle of the cassette and remove the gel Release the gel sandwich 3 To release the gel use an item such as the comb to loosen one corner of the gel sandwich and separate the glass plates Retain the gel and the EZ PAGE Electrode Cap EZ PAGE User Manual Downstream Processing The gels are ready for staining or for blotting using standard protocols Disposing of the EZ Gel Cassette Components Once the gel has been removed from the glass plate dispose of all remaining glass and plastic components except the EZ PAGE Electrode Cap and color coded cables These can be reused for your next electrophoresis run All plastic and glass parts are made from recyclable materials Please recycle them Dispose of the buffer appropriately EZ PAGE User Manual Troubleshooting amp Technical Support Problem A white precipitate is observed in the buffer tank when the gel cassette is removed from the refrigerator Running buffer was spilled during gel set up m
4. ge and use conditions until the product expiration date If the product proves defective during this period EZBiolab Inc will repair or replace it at our option free of charge This warranty does not cover damage in transit damage caused by carelessness misuse or neglect normal wear through frequent use damage caused by solvent corrosion damage caused by improper handling or user alteration nor unsatisfactory performance as a result of conditions beyond our control EZBiolab Inc shall in no event be liable for incidental nor consequential damages including without limitation lost profits loss of income loss of business opportunities loss of use and other related damages however caused nor any damage arising from the incorrect use of the product 11 EZBiolab Inc 1033 3rd Avenue SW Room 215 Carmel IN 46032 USA Email service ezbiolab com Phone 317 691 9450 FAX 317 663 0721 Website www ezbiolab com For research use only not intended for diagnostic use All trademarks are marks of the EZBiolab Group or its affiliates 2013 EZBiolab Inc All rights reserved Rev 12 31 13
5. ion of electrode wires in the EZ PAGE Electrode Cap Check to ensure the connection of each cable to the power supply is correct The band will not affect the results because it runs faster than protein bands The band can be avoided by using EZ PAGE Loading Buffer from EZBiolab The band will not be observed if the electrophoresis is run for 60 minutes For technical support contact EZBiolab service ezbiolab com 10 Related Products EZ PAGE Products EZ Agarose Products EZ PAGE Gel Cassettes EZ Agarose Gel Cassettes EZ PAGE Electrode Cap EZ Agarose Electrode Cap EZ PAGE Sample Loading Buffer 4x LB1 EZ Agarose Sample Loading Buffer 4x LB2 Precise Protein M W Marker unstained MKPO001 100 bp DNA M W Marker MKD005 Low Range Protein M W Marker unstained MKP002 250 bp DNA MW Marker MKD004 Pre stained Protein M W Marker MKP003 1 Kb Plus DNA M W Marker MKDOO1 Warranty amp Liability This product was produced utilizing the highest practical standards of materials workmanship and design EZBiolab Inc warrants that the product has been tested and will meet or exceed published specifications This warranty is valid only if the product has been operated and maintained according to the instructions provided EZBiolab warrants EZ PAGE and EZ Agarose Electrode Caps for one year from the date of shipment and the disposable products to be free from defects in materials and workmanship under recommended stora
6. ning and drying the gels Please read the Material Safety Data Sheet MSDS for this product prior to use Product Description EZBiolab s EZ PAGE Electrophoresis System is an innovative product designed to simplify electrophoresis The system integrates running buffer with a precast gel to form a ready to use pre fabricated single disposable unit Because the buffer is preloaded and the gel is precast you only need to load your samples to start a gel electrophoresis run EZ PAGE gels eliminate the tedious steps of system assembling buffer preparation and gel casting and can be run using any power supply Compact All components including precast gel amp running buffer are integrated into a single disposable unit Convenient EZ PAGE gels are ready to use just load your samples Fast EZ PAGE gels can be run at lower voltage and electrophoresis is fast Long shelf life Gels are stable up to 18 months Compatible EZ PAGE gels are compatible with most common loading buffers staining techniques and standard blotting methods EZ PAGE User Manual Contents Each package includes 10 gel cassettes Each cassette contains running buffer and a precast EZ PAGE gel in a disposable tank 1 Buffer dam opener Specifications amp Storage Conditions Gel thickness 1 5mm Number of Wells 12 Stacking Gel 1 polyacrylamide Running Gel 8 12 or 6 18 polyacrylamide Maximum loading volume 30 uL Shelf Life
7. ore than 50 of the buffer remains in the tank Running buffer was spilled during gel set up less than 50 of the buffer remains in the tank There is no current during an electrophoresis run The tracking dye in the loading buffer runs up instead of down A broad blue band is observed at the electrophoresis front during arun This precipitate forms when the gels are stored below 4 C The cable connections to the EZ PAGE Electrode Cap or to the power supply may be loose Electrophoresis is running in the opposite direction The power cables were not correctly connected Although EZ PAGE gels are compatible with most commonly used loading buffers this band is observed with some loading buffers The band is due to the tracking dye in the loading buffer Solution The precipitate consists of crystals of SDS which will dissolve at room temperature If any crystals remain once the gel cassette is at room temperature they will not affect the electrophoresis run Up to 50 of the original buffer volume can be replaced with distilled water The gel will run normally under this condition but the run time will be longer than 40 minutes EZ PAGE Buffer A and Buffer B are available from EZBiolab Fill the anode side with Buffer A and the cathode side with Buffer B Ensure that the cables are firmly connected to the EZ PAGE Electrode Cap and the power supply If this does not solve the problem check the connect
8. s The dam has been scored for easy opening A special tool the buffer dam opener is included in each package to facilitate this process Insert the buffer dam opener so that the dam is placed between the two blades of the opener Firmly but slowly rotate the opener towards the cathode buffer side opposite side of the gel to snap the buffer dam Once the dam is broken stop the rotation EZ PAGE User Manual Buffer dam is broken Rotate firmly but slowly Note The bottom of the buffer dam will probably be connected to the central panel and hang in the cathode buffer reservoir This will not interfere with electrophoresis Proceed to the next step Alternatively the buffer dam can be opened by hand Loading Your Samples Remove the comb and load your samples A sample loading guide is built in for easy identification of the sample wells Remove the comb Load Samples EZ PAGE User Manual Installing the EZ PAGE Electrode Cap amp Cables 1 Slowly place the EZ PAGE Electrode Cap which contains the electrode wires on the top of the cassette this will result in the electrodes being inserted into the buffer Be careful not to spill the buffer Make sure the cap is firmly positioned on the top of the cassette Cover the running cassette with the EZ PAGE electrode cap The electrode rods are located in the cap Buffer dam 2 Insert the female end of each color coded cable into one of the two slots on the E
Download Pdf Manuals
Related Search
Related Contents
Standard Version Client Software Manual Tacens Ixion ECO Setting Manual -TSP100IIU- - STAR Invacare® Cadiz General Cleaning After Use Manual PDF Samsung SF-560R multifunctional MODE D`EMPLOI POUR RÉUSSIR SES PROJETS 取扱説明書 - 瀧住電機工業株式会社 L`entreprise fait partie d`IDENTEC GROUP, regroupant plus Guia de LAN Sem Fios Copyright © All rights reserved.