Home

USER MANUAL WEIGHT INDICATOR

image

Contents

1. ran rd 1 or rd br1 rd 6 or rd br 6 KEY none MODE FUNCTION MODE FUNCTION MODE FUNCTION TARE DISABLED TARE TARE ZERO DISABLED TARE ZERO MODE DISABLED TARE MODE PRINT DISABLED TARE ENTER PRINT C DISABLED TARE C Fn DISABLED TARE Fn In this configurations it s necessary to link the remote contol to the instrument rd br x All supplied radio remote controls function with the instrument In the rd 1 and rd 6 configurations it s possible to combine 3 remote controls It s possible to link a new remote control with TARE key and ZERO key pressed at length 3 seconds When the instrument displays aut rd by pressing ENTER key of the keyboard the new remote control is linked With C key of the keyboard if the serial number exists the remote control is removed In the multifunction configuration by pressing at length the C key it s possible to put the instrument in stand by by pressing C on the keyboard or any key on the remote control one returns to the weighing mode 9 9 DATE TIME ADJUSTMENT OPTIONAL OR INCLUDED DEPENDING ON THE MODEL The indicator can be fitted with the date time board optional or included depending on the model in this case the CLoCk message is shown when instrument is turned on To set the date time follow the procedure below Turn on the scale press the TARE key while the firmware version is displayed the display shows the tyPE menu
2. Press ZERO many times to scroll ahead through the parameters or TARE to scroll backwards until one finds the F ModE parameter Press ENTER PRINT to enter the menu Scroll through ZERO or TARE keys to find the CLoCk parameter Confirm with ENTER PRINT in this order one will be asked to enter the day month year hour and minutes The entry of each parameter must be confirmed with ENTER PRINT Press the C key many times until the message SAVE appears on the display Press ENTER PRINT to confirm the changes made or another key to not save NOTES With the 17 key indicator it is possible to programme the date and time during the weighing pressing in sequence the F and 8 keys lf the supplied cable is disconnected or the battery has been replaced the indicators supplied with a date time board can keep the date time for 5 minutes The CLoCk parameter is displayed if there is the date time option 34 DFW series indicators DFW_03 12 07 EN U 9 10 SCREEN SAVER FUNCTION OPTIONAL OR INCLUDED DEPENDING ON THE MODEL If the indicator is fitted with the date time function optional or included depending on the model it is possible to enable the Screen Saver after a programmable time from 1 to 255 minutes with the scale unloaded the time is shown on the display in the HH MM SS format and the clock symbol is enabled As soon as a weight variation is detected or a key
3. The indicator has an auto zero at start up function in other words it means that if at start up a weight within 10 of the capacity is detected it will be zeroed if the weight is not within this tolerance with a non approved instrument the display shows the present weight after a few instants while with an approved instrument ZEro is shown continuously on the display until the weight does not re enter within this tolerance the auto zero function at start up may be disabled in the set up environment only with non approved instrument see SEtuP gt gt ConFiG gt gt PArAM gt gt Auto 0 parameter TECH MAN REF By pressing the ZERO key for an instant while the version is shown in the LED display the indicator will show the following in this order MAStEr if the MAStr functioning mode has been selected or riPE if the rEPE functioning mode has been selected CLoCk if date and time is detected XX YY in which XX indicates the instrument type YY indicates the metrological software version XX YY ZZ is the installed software version XXXXXX is the name of the installed software bt XXX in which XXX is a number from 0 to 100 which indicates the battery level if present K X YY in which K identifies the type of keyboard K 0 5 key keyboard K 1 17 key keyboard X YY is the installed software version After this it shows the programmed capacity and the minimum division hi rES in case of NOT ap
4. In the automatic one there is the automatic acquisition of the stable weight therefore the display of the totAL message on the display and then the printing of the data n WEiGh SHOWS THE NUMBER OF THE WEIGHINGS AND THE TOTAL WEIGHT AFTER EVERY TOTAL OPERATION This step allows or not to show after each totalization the number of current weighing n X and the total accumulated until this moment FrZ tot FREEZING ON THE DISPLAY THE GENERAL TOTAL This step allows or not to freeze the displayed value of the general total of the weight totalized at the end of all totalizations until it goes under lt lt Min WGt gt gt orwhen the weight returns to Zero WAit St TIME TO WAIT BEFORE REACHING THE STABILITY AND TOTALIZE THE WEIGHT lt lt tot Mod gt gt MANUAL In this step is required insert a time seconds that is the maximum time to wait before reach stability and accept the totalizations CPS tAr COMPULSORY TARE BEFORE TOTALIZE only the first time This step allows the compulsory tare before execute a total TOTALISATION OPERATIONS In order to carry out the totalisation it is necessary to load the weight on the scale and press the MODE key if the automatic totalisation has not been set the weight is accumulated in two total levels a partial total and a general total The totals and the number of weighs are zeroed when the instrument is turned off it s possible to store permanently these data if the instrument is fit
5. With the DFWLID DFWLIDCC if you activate the tolerance check CHEK F ModE gt gt Funct gt gt Check RIF MAN T TECH MAN REF you have the option to choose the color for each threshold of Check under ok and over PROCEDURE After having entered the activation threshold the target and the tolerance values put the weight on the scale if the target is greater than 0 the display shows at regular intervals if the weight is within the entered tolerances Scale Display View Enable Relay Display Color DFWLID Weight lt thrESh White Weight lt Target t Min _undEr reL b 1 Yellow Target t Min lt Weight _oK X reL b 2 Green Weight Target 0K reL b 2 Green Weight lt Target t MAX OK X reL b 2 Green Weight gt Target t MAX oVEr reL b 3 Red Weight 2 thrESh reL b 4 NOTE X is the difference 1 digit between the weight on the scale and the target ACOUSTIC SIGNAL It is possible to enable an acoustic signal beep for the control of tolerance in two different mode b SeNS that is emitted when the weight is greater than the enabling threshold the frequency with which the acoustic signal is emitted increases when the weight approaches the target and vice versa When the weight reaches the target the indicator emits a different acoustic signal b out that is emitted when the weight is less than Target t Min or greater than Target t MAX To enable this function press the keys F and 6 in se
6. YES in the step SEtuP gt gt d SALE TECH MAN REF The tare operations will have the following specifications SCALE FUNCTIONING CAPACITY SEtuP gt gt d SALE gt gt rEM dSP gt gt no SEtuP gt gt d SALE gt gt rEM dSP gt gt yES no remote display for the visualization of the remote display for the visualization of the tare tare lt 100kg All the tare functions are disabled The SEMIAUTOMATIC TARE value can not be modified with a manual tare or from database The manual tare or from database can be entered or modified only with an UNLOADED scale and tare equal to zero It s possible to cancel the tare value only with an UNLOADED scale by pressing the ZERO key or by entering a manual tare equal to zero The SEMIAUTOMATIC TARE value can not be The SEMIAUTOMATIC TARE value can not be gt 100kg modified with a manual tare or from database modified with a manual tare or from database The manual tare or from database can be The manual tare or from database can be entered or modified only with an UNLOADED entered or modified only with an UNLOADED scale and tare equal to zero scale and tare equal to zero It s possible to cancel the tare value only with an It s possible to cancel the tare value only with UNLOADED scale by pressing the ZERO key an UNLOADED scale by pressing the ZERO key or by entering a manual tare equal to zero key or by entering a manual tare equal to ze
7. In the 17 key indicator during the weighing it is possible to view at any time the number of weighs and the accumulated net weight in the totals By pressing in sequence the F and 7 keys the following will be displayed in this sequence n x in which x is the number of weighs made totAL followed by the accumulated PARTIAL NET TOTAL By pressing in sequence the F and 6 keys the following will be displayed in sequence n x in which x is the number of weighs made totAL followed by the accumulated GENERAL NET TOTAL MEMORY STORAGES only for 17 key indicator It is possible to memorize the weigh totalisation in one of nine memory storages identified from 1 to 9 Press in sequence the F and 5 keys the display shows rn n Enter the desired storage number from 1 to 9 Now all the made totalisations are stored in the storage number just entered To change the storage repeat the same operations To recall or zero the PARTIAL TOTAL of a storage it is necessary to recall first its identifying number as previously described however the GRAND TOTAL s not available for each storage 56 DFW series indicators DFW_03 12 07 EN U NOTES The selected storage remains active for all the following totalizations until it is substituted with another All the values accumulated in the single storage numbers are automatically zeroed each time the instrument is turned off it s possible to store permanently these
8. It is possible to store a list that can contain up to 487 values of weight If the MAStr functioning mode and the EXtEnd protocol have been selected in the FunCt gt gt MAStr gt gt nuMSL gt gt ProtoC gt gt t KEyb gt gt WGh LSt step one can enable or disable the list of weighs no list disabled yES yES dir list enabled with access to the management menu of the list list enabled with direct access to the PC connection in this case the serial port selected for the communication with the PC PC SEL step TECH MAN REF is exchanged with the other available serial port for the downloading of the list on PC If the list of weighs is enabled in the FunCt gt gt MAStr gt gt nuMSL gt gt CLoS LS step one can enable or disable the closure of the list no closure of the list disabled yES closure of the list enabled Initialization of the memory For the functioning of the list of weighs with a new memory one has to execute the initialization of this device if the yES parameter has been set in the WGh LSt step it is necessary to enter in the dEL LSt step of the menu of the list the ErASE message is displayed and press ENTER PRINT to confirm the dEL message is displayed if the yES dir parameter has been set in the WGh LSt step one has to connect the indicator to the PC and execute the initialization through the Delete List function of the WeighConsole softwar
9. 39 11 3 SET POINT ON THE GROSS WEIGHT SIPO suoie lea 39 11 4 SET POINT ON THE NET WEIGHT GIP sustos ra dana 40 AF SIMU OUT RT INOU in ecb aeea a a eli E alia 40 11 6 SINGLE MULTISCALE REPEATER MAS scie Noe 42 116 1 LISTEN ONLY MASTER 2 ga arie nali niente Delirio ar I 42 110 2 MASTER CONFIGURATION Sc cl ao dt tear 42 116 3 UNCTONINOS rt ones pia aii 43 DFW series indicators DFW_03 12 10 EN U T 60 4EXEGUTIONOETHEPRINTOUTS called 44 11 6 5 LIST OF WEIGHS DFWPM10USB MODEL orrido 45 11 6 6 TURN OFF THE MASTER AND THE SLAVES cnica le n iii 47 11 7 ALIBI MEMORY ALibi OPTIONAL sole 47 11 8 TOLERANGEGHECK GAEGK li elise eleonora 50 11 9 SAMPLE WEIGHT PERCENTAGE PE 51 11 10 SINGLE SCALE REPEATERMEPE corna E Ee EAA sd erica 52 11 11 DISPLAY WITH SENSITIVITY X 10 ViSS TO BE USED IN TESTING DURING THE CALIBRATION 53 11 12 HOLD FREEZING THE WEIGHTON THE DISPLAYNLIE rara 53 11 A3 WEIGHT PEAKS DETEGTION PEA ssaa eee eda 53 11 14 HORIZONTAL TOTALIZER Sum of lots O a e 54 11 15 VERTICAL TOTALIZER Sum by recipe PS td data 57 11 16 PIECE COUNTING GOUN heron reina AR ARAE R ee iaia ata 57 12 INDICATOR CONNECTED TO PRINTER FUNCTIONING BY BATTERY M rien 58 13 INSTRUMENT MESSAGES WHILE IN USE oscilar 59 DECLARATION OF CONFORMITY sia ai 61 WARRAN Tina 61 DFW series indicators DFW_03 12 07 EN U 1 INTRODUCTION The purpose of this manual is to help the user get to know the weight ind
10. DEL and numeric keys To choose this type of remote control follow the below procedure Turn on the scale press the TARE key while the firmware version is displayed the display shows the typE menu Press ZERO many times to scroll ahead through the parameters or TARE to scroll backwards until one finds the F ModE parameter Press ENTER PRINT to enter the menu Scroll until one finds the ir ConF parameter and select it With the ZERO or TARE keys select the possible options none disabled remote control ir 19 19 key remote control is enabled All other options refer to other types of remote controls Confirm with ENTER PRINT Press the C key many times until the message SAVE appears on the display Press ENTER PRINT to confirm the changes made or another key to not save The remote control keys repeat the keys functions both the ones obtained with a SHORT pressing as well as those with a LONG pressing and they correspond to the following indicator keys KEY none MODE FUNCTION ir 19 MODE FUNCTION ZERO DISABLED ZERO TARE DISABLED TARE MODE DISABLED MODE PRINT DISABLED ENTER PRINT C DISABLED C NUMERIC KEYS DISABLED Numeric keys F1 DISABLED Fn F2 DISABLED Not managed F3 DISABLED Not managed By pressing at length the C key it s possible to put the instrument in stand by by pressing C on the keyboard or any key on t
11. Precision defined by the OIML to represent 3000 divisions TECH MAN REF means that an advanced function is being described therefore for the technical personnel which will be further explained in the corresponding technical manual DFW series indicators DFW_03_12 07_EN U 4 INSTALLATION Depending on the model the digital weight indicator can have a stainless steel case or in ABS whose external dimensions are shown in the figures below It is quite easy to use on a tabletop while if a fixed support is desired mounting on a rack shelf or column is relatively simple NOTE When the identification plate is supplied separately therefore not attached to the front panel it is advisable to attach it in the appropriate space on the indicator so that it can be identified 4 1 DFW METAL OR STAINLESS STEEL VERSIONS 1 Power supply input 2 PC connection input PC RS232 RJ45 DFW series indicators DFW_03_12 07_EN U 4 2 DFW ABS VERSION 1 Power supply input 2 PC connection input PC RS232 RJ45 DFW series indicators DFW_03_ 12 07 EN U 4 3 DFWL VERSION 1 PC connection input PC RS232 RJ45 2 Battery box for 4 AA batteries 3 Power supply input DFW series indicators DFW_03 12 07 EN U 4 4 DFWLB VERSION 1 Power supply input 2 PC connection input PC RS232 RJ45 DFW_03_12 07_EN_U DFW series indicators 4 5 DFWLI DFWLKI DFWLI
12. another key to not save NOTE If there is a printer once the functioning mode is selected the relative printout is automatically enabled depending on the type of printer selected in the SEtuP gt gt SEriAL gt gt CoM Prn gt gt Pr ModE TECH MAN REF 11 1 UNIT OF MEASURE POUNDS CONVERSION Std By pressing the MODE key the weight conversion between the scale unit of measure and lb is made and vice versa NOTES The conversion takes place for any unit of measure set during the calibration With APPROVED instrument the weight in pounds is displayed for 5 seconds after which the display goes to the scale unit of measure During the viewing in pounds it is not possible to print the weight when pressing ENTER PRINT the message ConV is shown and an acoustic signal is emitted 11 2 NET GROSS SWITCH ntGS If a tare is set by pressing the MODE key for about 3 second interval the gross weight is displayed NOTE While the gross weight is being viewed it is not possible to print 11 3 SET POINT ON THE GROSS WEIGHT StPG By selecting this functioning mode in the normal scale status one enables the function of the relays on the GROSS weight with the optional boards it is possible to use up to 4 relays In the outPut menu of the SET UP environment TECH MAN REF one sets the functioning mode for each relay used none with hysteresis enabling and disabling set point without hysteresis single set point Furthermore it i
13. cable 17 DFW series indicators DFW_03 12 07 EN U 5 3 DFWPM POWER SUPPLY The instrument can be powered with 4 AA rechargeable or not rechargeable batteries which are in the extractable battery box It is also possible to power the indicator with a 5 Vdc voltage supplied by the USB port connected to the PC depending on the indicator model NOTE if the AA rechargeable batteries are used not supplied the recharge MUST be made separately using the proper battery charger not supplied TO INSERT OR REMOVE the AA batteries pull out the battery box which is found on the upper side of the instrument chapter INSTALLATION remove the discharged batteries and insert the new ones according to the shown polarity then insert the battery box again TO POWER the instrument using USB PC port connect the USB port placed on the upper side of the instrument chapter INSTALLATION to the PC USB port through a standard USB cable 5 4 TURNING ON OFF THE INSTRUMENT TO TURN ON the instrument press the C key until the indicator turns on then release The display shows XX YY is the installed software version The instrument turns on all the display segments and symbols MAX XXX XXX capacity of channel 1 or MASTEr if the MAStr functioning mode has been selected or riPE if the rEPE functioning mode has been selected bt XXX in which XXX is a number from 0 to 100 which indicates the percentage of battery level if present
14. e a weight of 100 divisions below the gross zero if the instrument is approved is blinking notified through this message and by an acoustic signal oVEr the weight in overload i e a weight of 9 divisions greater than the capacity is notified through this message blinking and by an acoustic signal ECo X It is displayed for an instant if the master can connect to the slave X if the connection is not possible the message remains fixed and the master emits an acoustic signal 60 DFW series indicators DFW_03 12 07 EN U DECLARATION OF CONFORMITY This device conforms to the essential standards and norms relative to the applicable European regulations The Declaration of Conformity is available in the web site www diniargeo com WARRANTY The TWO YEARS warranty period begins on the day the instrument is delivered It includes spare parts and labour repair at no charge if the INSTRUMENT IS RETURNED prepaid to the DEALER S PLACE OF BUSINESS Warranty covers all defects NOT attributable to the Customer so are not included in the warranty failures resulting from improper use and NOT caused during transport If on site service is requested or necessary for any reason where the instrument is used the Customer will pay for all of the service technician s costs travel time and expenses plus room and board if any the Customer pays for the transport costs both ways if the instrument is shipped to DEALER or man
15. function of the operating mode set in the set up environment In the numeric input phase it confirms the entry made In the SET UP it allows to enter a step or to confirm a parameter within a step It transmits the data from the serial port dedicated to the printer Cli It turns the instrument on and off In the numeric input phase it quickly zeros the present value In the SET UP it allows to exit a step without confirming the change made in the 5 key indicator Allows viewing the scale s metric information capacity division minimum weigh for each configured range 23 DFW series indicators DFW_03_12 07_EN_U 7 FRONT PANEL KEYS AND INDICATORS 17 key version The front panel of the indicator is designed for quick and simple weighing applications It consists of an LCD display with 6 digits 25 mm in height 7 LED indicators depending on the model and a water proof film keyboard with 17 numeric and function keys If the indicator has an LCD display while weighing various multifunction symbols indicating the functioning status will turn on see section SYMBOLS ON THE LCD DISPLAY DFWLKI DFWK 24 DFW series indicators DFW_03_12 07_EN_U Cle CC ClO Ore ZERO TARE MODE DFWR Indicates the presence of power supply Sensor for the reception of the remote control signal Indicates that the weight detected by the weighing system is close to zero within of the d
16. is pressed the indicator returns to view the current weight To set the function Turnon the scale press the TARE key while the firmware version is displayed the display shows the tyPE menu Press ZERO many times to scroll ahead through the parameters or TARE to scroll backwards until one finds the F ModE parameter Press ENTER PRINT to enter the menu Scroll to find the SCr SAV parameter and select it With the ZERO or TARE key select the possible options no disabled YES enabled Confirm with ENTER PRINT if one has selected yES one is asked to enter the number of minutes after which the indicator should show the time enter a number between 1 and 255 using the MODE key to select the digit to be modified and the ZERO TARE keys to decrease increase it and confirm with ENTER PRINT Press the C key many times until the display shows the message SAVE Press ENTER PRINT to confirm the changes made or another key to not save NOTE the SCr SAV parameter is shown if there is the date time option 9 11 KEYBOARD LOCK It is possible to disable the keyboard functions in order to avoid accidental pressing of the keys The keyboard can be disabled enabled by setting the corresponding parameter in the F ModE gt gt LCk kEy step of the setup environment TECH MAN REF if the on parameter is selected in the this step after 15 seconds of keyboard inactivity in the wei
17. is zeroing the weight AL Err It is displayed when one selects the alibi memory functioning mode and upon start up the alibi memory is not connected or there are communication problems between the indicator and the board The unit of measure pounds conversion functioning is automatically set but not saved in the set up environment Er i b X A function has been linked to input X from 1 to 4 and this is not present see the InPutS parameter of the set up environment TECH MAN REF Er r b X In a set point functioning mode the relay X has been set from 1 to 4 and this is not present see the outPut parameter of the set up environment TECH MAN REF buSy Print under way PRN serial port is occupied or indicator waiting to transmit a printing to a PC unStAb One is trying to print with an unstable weight un oVEr One is trying to print with the weight in underload or in overload in other words with a weight of 9 divisions greater than the capacity or of 100 divisions below the gross zero LoW Weight less than the minimum weight provided for the printing the totalisation or the transmission of the string standard or extended upon pressing of the print key no 0 unS Weight not passed by net 0 or by instability ConV In standard mode with approved instrument one is trying to print while the instrument is converting the unit of measure no in In the input output mode set as in out one is trying to acquire a se
18. more LISTEN ONLY MASTER having the sole function of repeating the weight 11 6 1 LISTEN ONLY MASTER One can also add other masters see next paragraph which must be set as weigh repeater The keys pressed on these masters are not repeated on the slaves When the listen only master is turned on it displays the weight of the slave or automatically selects the sum of the weights if there are more slaves connected to the master If there are more slaves the listen only master can display the sum of weights if it is selected on the listen only master and also on the master the sum is displayed the SuM message is displayed every 10 seconds the weight of the selected slave if the master displays the weight of the same slave or the sum of weights the SCA n message is displayed n is the number of the selected slave If it is not possible to set the communication the listen only master displays the central segments alternated to the messages SCA n or SuM NOTE this type of master works if there is at least one master in no listen mode 11 6 2 MASTER CONFIGURATION In the MASTER by selecting with ENTER PRINT in this operating mode one is asked to enter the number of the SLAVES which one wants to use for an instant nuMSL is displayed then one enters the number between 01 and 32 one is asked to select the listen only mode or not one is asked to select the enable print on the master or not must be
19. shows the tyPE menu Press ZERO many times to scroll ahead through the parameters or TARE to scroll backwards until one finds the F ModE parameter Press ENTER PRINT to enter the menu the display shows the FunCt menu Press ENTER PRINT to enter the parameter With the ZERO or TARE keys select the possible options MAStr Single multiscale repeater rEPE Single scale repeater NOTE The above parameters are only displayed if the firmware the instrument is MASTER type Std Unit of measure pounds conversion ntGS Net weight gross weight conversion StPG Set point on the GROSS weight StPn Set point on the NET weight inout Input output weighing ALibi Alibi memory ChECk _ Tolerance Check PErC Sample weight percentage ViSS Sensitivity times ten hLd Hold PEAk Peak detector toto Horizontal totalizer tot S Vertical totalizer Coun Counting NOTE The above parameters are only displayed if the firmware the instrument is STANDARD type 38 DFW series indicators DFW_03_12 07_ EN U Confirm with ENTER PRINT if one has selected the inout MAStr ChECk PErC tot o tot S or Coun mode one will be asked to select one or more operating parameter refer to the specific functioning mode section for the relative description The instrument automatically goes to the following step Press many times the C key until the display shows the message SAVE Press ENTER PRINT to confirm the changes made or
20. the capacity is equal or less than 100 kg 220 Ib 11 12 HOLD FREEZING THE WEIGHT ON THE DISPLAY hLd By pressing MODE the value of the weight is held on the display and the display shows hoLd alternately with the held weight value every 5 sec To release the weight value on the display press MODE key again the norMAL message is displayed By pressing MODE at length it is possible to enter in a menu for the selection of the type of functioning StAtiC static functioning previously described hoLd 0 hoLd 5 dynamic functioning for weighing of moving objects for example animal weighing the higher the numeric parameter greater is the intervention of the HOLD function Press ZERO or TARE key to change the parameter and ENTER PRINT to confirm Then press MODE to enable the selected functioning by pressing again the MODE key the function is disabled 11 13 WEIGHT PEAKS DETECTION PEAk It is possible to use the instrument to store the maximum weight value measured during the weigh PEAK useful to measure for example the breaking load of the materials By pressing the MODE key the peak mode is enabled on the LED display the maximum weight reached will be displayed alternated with the message PEAk every 5 sec The test terminates by pressing the MODE key again or when the weight peak surpasses the maximum capacity of the instrument for an instant PEAk oF is displayed and the indicator returns to stan
21. the display the net weight expressed as a percentage comparing it with a reference weight which has been previously linked to a percentage When the functioning mode is selected one is asked to set of WAit t sampling interval Setting of the sampling time in seconds with a decimal greater is the time set and more precise will the sampling be e Set the desired time e Confirm with ENTER PRINT e Press many times the C key until the display shows the message SAVE With the indicator fitted of a 17 key keyboard by pressing the F and 7 keys it s possible to change the sampling time SI DFW series indicators DFW_03_12 07_EN_U also in the weighing mode If the entered value is confirmed it will substitute the one in the set up environment PROCEDURE 1 Place the empty container on the scale and press TARE to tare it 2 Check that the zero is on the display and press MODE 3 The display suggests a percentage the possible options are 100 0 200 0 5 0 10 0 20 0 30 0 40 0 50 0 60 0 75 0 4 Press ZERO or TARE several times to reach the desired sample size 5 Put the reference weight on the scale and press ENTER PRINT to confirm or C to cancel the operation and return to weighing 6 Press ENTER PRINT the display will show SAMPL After a few instants the display will show the selected percentage put on the platform 7 Add the quantity to be measured on the scale and the value will appear on t
22. the parameters or TARE to scroll backwards until one finds the F ModE parameter Press ENTER PRINT to enter the menu Scroll until one finds the ir ConF parameter and select it With the ZERO or TARE keys select the possible options none disabled remote control ir 18 18 key remote control is enabled All other options refer to other types of remote controls Confirm with ENTER PRINT Press the C key many times until the message SAVE appears on the display Press ENTER PRINT to confirm the changes made or another key to not save The remote control keys repeat the keys functions both the ones obtained with a SHORT pressing as well as those with a LONG pressing and they correspond to the following indicator keys 32 DFW series indicators DFW_03_12 07_EN_U KEY none MODE FUNCTION ir 18 MODE FUNCTION ZERO DISABLED ZERO TARE DISABLED TARE MODE DISABLED MODE PRINT DISABLED ENTER PRINT Fn DISABLED Fn C DISABLED C NUMERIC KEYS DISABLED Numeric keys By pressing at length the C key it s possible to put the instrument in stand by by pressing C on the keyboard or any key on the remote control one returns to the weighing mode 9 8 3 NINETEEN KEY IR REMOTE CONTROL NOTE indoor use only If the model is provided for the 19 key remote control it is possible to remotely use the functionality of the ZERO TARE MODE ENTER PRINT Fn C
23. 0 To carry out a new reference operation press at length the MODE key and repeat the operations as describe in point 3 NOTE If the number of calculated pieces is greater than 999999 the display shows just the first 6 digits on the right 57 DFW series indicators DFW_03 12 07 EN U PIECE COUNTING IN EXTRACTION 1 Load a FULL container on the scale and press TARE to tare it 2 Press MODE The display suggests various REFERENCE QUANTITIES 5 10 20 30 40 50 60 75 100 200 3 Press ZERO or TARE various times until the chosen quantity is displayed 4 From the container take off the same number of pieces and press ENTER PRINT to confirm The display shows SAMPL while the indicator calculates the Average Piece Weight The display shows in negative the quantity extracted 5 Continue the counting in extraction Er Mot ERROR DUE TO WEIGHT INSTABILITY DURING THE SAMPLING It may happen that during the sampling phase the weight is unstable and therefore it is not possible to correctly calculate the APW The Er Mot is shown remaining for about three seconds One should therefore repeat the sampling operation MINIMUM WEIGHT OF THE SAMPLE It is advisable to use a reference quantity equal or greater than 0 1 of the scale capacity In any case the weight of the reference quantity should not create an APW lower than the two internal points of the converter intrinsic limit of the instrument if this condition takes place
24. 350 Ohms 6 wires CELL1 with Remote Sense 4 wires CELL 2 3 4 without Remote 6 DFW series indicators DFW_03 12 07 EN U Sense I O SECTION DFW 1 RS232 TTL input output configurable for connection to PC PLC or WEIGHT REPEATER 1 RS232 input output for connection to printer DFWL DFWLB DFWLI DFWLIB DFWLKR DFWLID 1 RS232 TTL input output 1 RS232 485 input output Configurable for connection to PC PLC WEIGHT REPEATER or PRINTER DFWLKRF 868Mhz integrated radio modem for communication with the scale 1 RS232 input output for connection to printer DFWPM 868Mhz integrated radio modem for communication with the scale USB port DFWPM10USB model DFWLAP 868Mhz integrated radio modem for communication with the scale CLOCK DFW optional with battery DFWL DFWLB DFWLI DFWLIB DFWLKR DFWLKRF DFWPM DFWLID DFWLIDCC fitted internally date and time stored for 5 minutes in case of power supply disconnection or battery replacement or external optional with battery THE PARTS OF THE INSTRUMENT CONTAINING DANGEROUS ELECTRICAL TENSION ARE ISOLATED AND INACCESSIBLE TO THE USER UNLESS IT HAS BEEN DAMAGED OPENED OR ALTERED 3 SYMBOLS To call the attention of the user the following symbols are used both in the manual and on the instrument itself A WARNING This operation must be performed only by qualified personal Conforms to the standards of the European Union CID Identifies the Class Of
25. B VERSION DFWLKI DFWLI 101 _ LD i CLORCEORS 243 A 1 Power supply input 2 PC connection input PC RS232 RJ45 DFW series indicators DFW_03_12 07_EN U 4 6 DFWLID DFWLIDCC VERSION 1 Power supply input 2 PC connection input PC RS232 RJ45 DFW series indicators DFW_03_12 07_EN U 4 7 DFWPM VERSION 4 i A ca LL EAS rie ON ES y aa rali A N O O 0 O 0 os ae se e No UL A DAR L L Y Y L 178 a dA i un z A NA DZ 1 1 USB input with PC 5V power supply input 2 Battery box for 4 AA batteries DFW series indicators DFW_03_12 07_EN U 4 8 DFWLKR DFWLKRF VERSIONS 1 Power supply input 2 PC connection input PC RS232 RJ45 3 Load cells connection 12 PIN cable DFW series indicators DFW_03_ 12 07 EN U 4 9 DFWLAP VERSION 1 Power supply input DFW series indicators DFW_03 12 07 EN U 5 POWER SUPPLY AND START UP 5 1 DFWLKR DFWLKRF DFWLAP POWER SUPPLY The instrument can be powered with a 6 Vdc tension supplied from an AC DC external adapter which should be connected t
26. BLING THE PRINTOUTS AND THE INDICATOR FUNCTIONS The tare operations are DISABLED 41 DFW series indicators DFW_03_12 07_EN U 11 6 SINGLE MULTISCALE REPEATER MAStr MAStEr nuMSL 1 01 32 gt LiStEn 1 no yES Ed Print gt no yES ExtEnd gt ProtoC 8 gt norMAL kb dFW kb dFkr tkEyb kb dGt kb CPWE kb 3590 no yES gt WGh LSt gt yES dir CLOS LS gt no yES SuM PAr gt SuM dEC 1 0 3 y SuM diV gt 1 200 gt SuM MAX 1 0 999999 y SuM uM 8 gt 1 kg g Ib t The system is made up of one or more indicators up to 32 called SLAVES connected to one or more weighing system which communicate with another indicator called MASTER which acts as weight repeater on which it is possible to view or printed if the printer is provided the weight of each single scale or the sum of the weighs detected by the single scales Slave can be connected to up to 4 platforms with dependent or independent channels Slaves also repeat some of the keys pressed on the master such as tare or zero NOTE It is possible to achieve a network with a MASTER which remotely performs the functions of the scales connected and one or
27. EAK The PEAK function is enabled 21 HOLD The HOLD function is enabled 22 SP1 The relay nr 1 optional has been enabled SP2 The relay nr 2 optional has been enabled SP3 The relay nr 3 optional has been enabled SP4 The relay nr 4 optional has been enabled 28 DFW series indicators DFW_03 12 07 EN U 9 BASIC FUNCTIONS 9 1 ZERO SCALE By pressing the ZERO key it is possible to zero a gross weight value which is within 2 of the capacity after the zeroing the display shows 0 weight and the relative pilot lights are turned on 9 2 TARE OPERATIONS SEMI AUTOMATIC TARE By pressing the TARE key any weight value present on the display is tared the display shows tArE for an instant and then 0 net weight the pilot lights turn on NOTE The semiautomatic tare will be acquire only if the weight is AT LEAST A DIVISION STABLE instability led off and VALID in other words the OVERLOAD condition must not be created ENTERING THE MANUAL TARE FROM KEYBOARD With the 5 key indicator Press TARE for a few seconds the display shows tM and then 000000 Enter the desired value using the following keys ZERO decreases the blinking digit TARE _ increases the blinking digit MODE selects the digit to be modified blinking the scrolling of the digits takes place from left to right C if pressed for an instant it quickly zeros the present value if pressed at length it allows to return to weig
28. INALDLOK lt CR o CRLF gt if the cancellation has been effective INALDLNO lt CR o CRLF gt if the cancellation has not worked NOTE During the cancellation the display shows WAit and all the indicator functions are frozen The commands are ignored if one is not in the alibi memory functioning mode 11 8 TOLERANCE CHECK ChECk In this functioning mode the instrument commands the functioning of the SP1 SP2 SP3 and SP4 icons of the LCD display and the functioning of the 4 relays of the 2 expansion boards optional on the basis of a freely programmed TARGET WEIGHT a LOWER TOLERANCE value an UPPER TOLERANCE value and an ENABLING threshold It is possible to carry out a check on the gross weight or the net weight in the TECHNICAL set up after the selection of the Check mode one is asked to select GroSS gross weight or nEt net weight The selection of the check type net or gross causes the configuration of the relay s relative default parameters By setting the threshold for activating the functioning mode if the weight is under the set threshold no check on the weight is made if instead the weight reaches or surpasses the threshold the check on the tolerances is enabled ENTERING THE ACTIVATION THRESHOLD TARGET AND THE TOLERANCES Press the MODE key the instrument first shows ArGEt then 000000 or the target previously used With the keyboard enter the desired target with C one quic
29. REF but not in the MASTER itis possible to execute the printout configured in the SLAVE 44 DFW series indicators Examples of printout 2 slaves connected to the master TPR printer Slave 1 SCALE 1 MASTER LINE 1 MASTER LINE 2 MASTER LINE 3 MASTER LINE 4 SLAVE 1 LINE 1 SLAVE 1 LINE 2 SLAVE 1 LINE 3 SLAVE 1 LINE 4 GROSS 5 848 kg TARE 0 800 kg NET 5 888 kg NOTES Slave 2 SCALE 2 MASTER LINE 1 MASTER LINE 2 MASTER LINE 3 MASTER LINE 4 SLAVE 2 LINE 1 SLAVE 2 LINE 2 SLAVE 2 LINE 3 SLAVE 2 LINE 4 GROSS 1 743 kg TRRE 0 008 kg NET 1 743 kg Master MASTER MASTER MASTER MASTER SCALE SCALE PT SUM ASAS NN LINE LINE LINE LINE 1 2 CO PD If the printer has been selected in the MASTER but not in the SLAVE it is not possible to print If more than one SLAVE is present the number of the SLAVE from which the weight comes from will be added on each printout on the MASTER If enabled the master inserts the header If enabled the master adds at the end of the format the ticket number and date amp time ASAS AI NI NAI NAI NIN NNN NN 743 kg DFW_03_12 07_EN_U 080 kg 743 kg BAB kg ASAS NN On the MASTER it is also possible to display and print the sum of the weights of a number of SLAVES lower than the value programmed in the FunCt gt gt MAStr gt gt nuMSL step by turning off the SLAVES that are not used 11 6 5 LIST OF WEIGHS DFWPM10USB MODEL
30. THE NET WEIGHT StPn By selecting this functioning mode in the normal scale status one enables the function of the relays on the NET weight the entry of the SET POINTS and the functioning notes are the same as the gross weight mode 11 5 INPUT OUTPUT inout Simple display functioning mode with in out weighing function the indicator acquires two weight values through the confirmation of the operator and calculates the difference automatically printing the data if the presence of a printer has been configured Once the in out mode has been selected the message tyPE is shown and one is asked to select with ENTER PRINT the printing mode of the acquired data G t gross tare GROSS Greater weight with unit of measure TARE Lesser weight with unit of measure NET Difference between GROSS and TARE with unit of measure 1st 2nd first weigh second weigh WEIGH 2 Second weight with unit of measure NET Difference without sign between WEIGH 1 and WEIGH 2 with unit of measure 40 DFW series indicators DFW_03 12 07 EN U in out input output INPUT First weight with unit of measure OUTPUT Second weight with unit of measure NET Zero weight with unit of measure gt gt if WEIGH 1 WEIGH 2 INPUT NET gt gt if WEIGH 1 gt WEIGH 2 Difference without sign between INPUT and OUTPUT with unit of measure OUTPUT NET gt gt if WEIGH 1 lt WEIGH 2 Difference without sign between INPUT and OUTPUT with unit of measure PROCED
31. URE With the MODE key of the 5 key indicator or keys F 1 of the 17 key indicator one acquires the first weight on the display is shown 1 accompanied by a prolonged beep By pressing again the MODE key of the 5 key indicator or keys F 2 of the 17 key indicator one acquires the second weight and on the display is shown 2 accompanied by a prolonged beep NOTE The acquisition of the second weight is made only if the setting of the rEACt parameter in the set up environment has been respected passage by zero of the weight instability or always see the section REENABLING THE PRINTOUTS AND THE INDICATOR FUNCTIONS When the second weight is acquired the data printout is commanded It is possible to interrupt the weighing cycle by pressing the ENTER PRINT key in the 5 key indicator or C in the 17 key indicator after the acquisition of the first weight on the display the message CLEAr is shown accompanied by a prolonged beep Press ENTER PRINT to confirm the cancelling of the first acquired weight or another key to not confirm NOTES The weight is acquired if With a NON APPROVED scale one has a STABLE weight and GREATER than 0 With an APPROVED scale one has a STABLE weight and GREATER than 20 divisions If the setting of the rEACt parameter in the set up environment has been respected passage by zero of the weight instability or always see the section REENA
32. USER MANUAL WEIGHT INDICATOR DFW INDICATOR REPEATER TRANSMITTER OF WEIGHT DFW_03_12 10 EN U DFW series indicators DFW_03 12 10 EN U INDEX INTRODUCTION ulcera 4 2 MAIN TECHNICAL SPECIFICATIONS cion amarse dnd aii 6 S SYMBOL AA A Patch cadens ts a Aaa A ast ceca ETa aa LAAI Ea AAS aca ranba K aN NH Anaa ARa To popi 7 A INSTALLATION celata 8 4 1 DFW METAL OR STAINLESS STEEL VERSIONS nai dd dass patito 8 4 2 DFEWABS VERSION scialli iaia 9 43 DEWEVERSION dreien inte hans E E E EE A ES 10 4 4 DIE WEB VERSION release 11 4 5 DFWLI DFWEKI DFEWLIB VERSION iia ap ire dt 12 4 6 DFWLID DFWLIDCC VERSION 0 td LI i E neri 13 4 T DFWPM VERSION ee nina 14 AO DEWLKRA DEWERRE VERSIONS cutre ada 15 4 9 DFWLAP VERSION contenidas tit data riada 16 9 POWER SUPPLY AND START UP anae e ala iaia 17 5 1 DFWLKR DFWLKRF DFWLAP POWER SUPPLY arl alii as ulcer dk ae ali a 17 5 2 DFW DFWLI DFWLIB DFWL DFWLB DFWLID DFWLIDCC POWER SUPPLY 17 0 3 DFWPM POWER SUPPLY terra leleine ail 18 5 4 TURNING ON OFF THE NSTROMEN apt ae e e do 18 6 FRONT PANEL KEYS AND INDICATORS 5 key Version ssssssssesessessseeeeeseeneieassesnenesseeeeeeeeeeeeeneeaneneneeseneneeeeees 19 7 FRONT PANEL KEYS AND INDICATORS 17 key Version sssssscsssssssseeeseseseeieseseesensneseeeeeseeenenneaneneneneeeseneeeees 24 8 SYMBOLS ON THE LOD DISPLAY srl lilla da ii aaa 27 9 BASIC FUNCTION S our A A iia 29 o PIETA o LO O A E 29 9 2 TARE OPERATIONS r
33. ach time ENTER PRINT is pressed while either weight or pieces are displayed one prints the data programmed in the SEtuP gt gt SEriAL gt gt CoM Prn gt gt Pr ConF of the set up environment TECH MAN REF for example GROSS weight TARE weight NET weight Quantity of PIECES PCS on the scale in that moment calculated APW expressed in the set unit of measure with three decimal digits 12 INDICATOR CONNECTED TO PRINTER FUNCTIONING BY BATTERY In a system made up of an indicator connected to a printer in which both are battery powered the printer normally in STAND BY will be powered only when one prints When the printing is finished the printer returns to STAND BY automatically This functioning is useful to reduce the energy absorbed from the battery when the printer is not used In this configuration if one has the need to maintain the printer powered in order to replace the paper and for other operations Press the ZERO key for a few seconds On the display the blinking onPri message will appear 58 DFW series indicators DFW_03 12 07 EN U Press any key to exit NOTE it is not possible to turn on the printer with the ZERO key in the REPEATER IN RADIO FREQUENCY functioning mode The printer is now on carry out the desired operations 13 INSTRUMENT MESSAGES WHILE IN USE MESSAGE DESCRIPTION ZEro The scale
34. arts working when the instrument s inclination is greater than 2 for the pallet truck application or 5 for application on lift trucks The tilt message the weight value are alternately shown on the display The activation of the tilt alarm has a delay of about three seconds from the detection of the exceeding inclination See the electrical connection scheme TECH MAN REF for the connection of the device 9 7 MULTI RANGE FUNCTIONING for legal for trade approved instruments The multi range functioning allows to subdivide the scale capacity in two or three ranges each which is up to 3000 divisions improving in this way the first range division in the dual range and the first two ranges in the triple range For example with a 30 kg cell platform it is possible to approve the weighing system with A single range 6 kg capacity and 2 g division 3000 div Dual range 6 3 kg capacity and 2 1 g division 3000 3000 div Triple range 15 6 3 kg capacity and 5 2 1 g division 3000 3000 3000 div NOTES For the approval of the weighing system in dual and triple range the cell must have better technical features in comparison to the cell used for the approval in a single range The multirange functioning is shown by the turning on of the relative LED which identifies the range in which one is operating by passing to the second range the second range division is enabled by passing to the third range the third range d
35. ayed press the ENTER PRINT key to confirm the LiSt message is displayed or the C key to exit from the step without printing If one confirms with ENTER PRINT but the list is empty the EE EMP message is displayed dEL LSt List deletion from the memory by pressing the ENTER PRINT key the ErASE message is displayed press the ENTER PRINT key to confirm the dEL message is displayed or the C key to exit from the step without deleting the memory n SLAVE Selection of one slave or the sum by pressing the ENTER PRINT key the display shows the S xx message it is possible to insert the number of the slave or the value 00 to select the sum of the weights The step is displayed only if more than one slave are set in the nuMSL step oFF MSt It allows to turn off only the master by pressing the ENTER PRINT key Direct access to the PC connection The PC WAit message is displayed it is possible to download the list on PC with WeighConsole see the manual of the DiniTools software or one can send serial commands to the indicator to manage the memory see section FORMAT OF THE SERIAL COMMANDS TECH MAN REF if the list is empty the message EMPTY is displayed and the indicator is not connected to the PC 46 DFW series indicators DFW_03 12 07 EN U By pressing any key the connection is disabled the next step in the menu is displayed to reactivate it one has to select the PC C
36. been made the quantity percentile is not printed 11 10 SINGLE SCALE REPEATER rEPE The system is made up of one or more indicators named REPEATERS which receive the data of the display or of the weight from another indicator or from a PC PLC named TRANSMITTER and which therefore act as repeaters In the REPEATERS once this functioning mode has been set one should configure the rEPE 6 rEPE dC Pr1577 or W rEPE parameter in the communication mode of the PC serial port SEtuP gt gt SEriAL gt gt CoM PC step TECH MAN REF For further configuration and functioning details refer to the technical manual SEtuP gt gt SEriAL gt gt CoM PC step and section SERIAL PORT TRANSMISSION MODES TECH MAN REF If rEPE 6 rEPE dC or Pr1577 communication protocol has been set in the REPEATER one will need to set the rEPE 6 communication protocol in the TRANSMITTER on the desired port If W rEPE communication protocol has been set in the REPEATER one will need to set the protocol of the continuous weight transmission on the desired port of the TRANSMITTER For further configuration details refer to the technical manual of the connected indicator 52 DFW series indicators DFW_03 12 07 EN U FUNCTIONING When the indicator is turned on it waits for the data if it does not receive a correct communication string the communication parameters are wrong or it does not receive any character it remains in the te
37. cond time the input weight no out In the input output mode set as in out one is trying to acquire a second time the output weight no 1 In the input output mode set as G t or 1st 2nd one is trying to acquire a second time the input weight no 2 In the input output mode set as G t or 1st 2nd one is trying to acquire a second time the output weight Er Mot Unstable weight Error In the counting mode the sampling has not been made because one should use a higher reference quantity In the equalization procedure the cell that is being equalized is not the cell with the greater weight Eq Err It is displayed if it was not possible to perform the equalization StorE It is displayed when data is stored in the permanent storage of the instrument setpoint tares etc Err CLk Communication problems with the date time of the indicator check the F ModE gt gt CLoCk step of the set up TECH MAN REF SEt CLk Date time not set check the F ModE gt gt CLoCk step of the set up TECH MAN REF PrEC It is displayed if one tries to calibrate the zero point without first having confirmed the number of calibration points ErPnt During the acquisition of a calibration point a null value has been read by the converter Err rF Selecting the MASTER functioning mode this message is show when it s enabled the radio and enabled the energy saving mode it is displayed when the indicator doesn t detect the SLAVE
38. connected to a printer NOTE Only one master can have the print option set to YES if listen mode no one is asked to enter the protocol type 42 DFW series indicators DFW_03 12 07 EN U if listen mode no one is asked to enter the SLAVE keyboard type kb dFW for DFW type instruments kb dFkr for DFWKR type instruments kb dGt for DGT type instruments kb CPWE for CPWE 3590E type instruments kb 3590 for 3590 type instruments inthe DFWPM10USB model if the extended protocol EXtEnd has been selected one is asked to disable the list of weighs or to enable it in one of the two available functioning modes if the list of weights is enabled must be set the close list parameter CLoS LS if two or more slaves are set the menu SuM PAr for the setting of the parameters of the sum is displayed press ENTER PRINT to access to the parameters SuM dEC number of decimals between 0 and 3 SuM uM unit of measure one can select kg g Lb or t SuM diV minimum division the possible values are 1 2 5 10 20 50 100 200 SuM MAX maximum value displayed between 100 and 999999 without decimals if the sum of the weights has a value of more of 9 sum divisions SuM diV greater than the value set in this step the message oVEr is alternated to the display of and an acoustic signal is emitted The 0
39. dard operation SETTING SAMPLING TIME It is possible to set the minimum time period of the peak impulse beyond which the measuring is accepted This time is set by keeping ENTER PRINT pressed for a few seconds when the indicator is not in the peak mode the message tP appears on the display followed by a number which corresponds to the minimum time length of the impulse expressed in hundredths of seconds By pressing ZERO or TARE the following settable values are proposed 1 2 3 4 5 10 20 50 100 and 127 press ENTER PRINT to confirm the desired value the indicator will return to weighing The default value is 2 53 DFW series indicators DFW_03_ 12 07 EN U TABLE OF OPERATING PARAMETERS IN PEAK MODE LENGTH SAMPLINGS PER SECOND ACQUIRED VALUES MEDIATED VALUES 1 400 1 1 2 200 1 1 3 100 1 1 4 100 4 2 5 50 4 2 10 25 4 2 20 12 4 2 50 6 4 2 100 6 8 2 127 6 12 2 When enabling the PEAK mode it s possible that the displayed weight isn t really the one on the scale Greater the number of samplings per second and greater is the weight that can be shown on the display E g if 0 000Kg is on the scale and the sampling time is equal to 1 when the PEAK mode is enabled 0 034Kg could be displayed 11 14 HORIZONTAL TOTALIZER Sum of lots tot 0 Once the totalizer operating mode is selected both horizontal tot 0 and vertical tot S is asked to set th
40. data if the instrument is fitted with the date time board When turned on the indicator automatically goes to storage nr 0 if the instrument is fitted with the date time board when the indicator is turned on it goes to the last storage selected Storage nr 0 is considered to be the basic one in which non addressed weights are accumulated 11 15 VERTICAL TOTALIZER Sum by recipe tot S Like the horizontal totaliser but with each pressing of MODE the indicated weight is totalised and automatically tared in this way it is possible for example to fill a container with various products Note At the end of the totalisation operations if one wants to view the gross weight on the scale one should press the C key 11 16 PIECE COUNTING Coun In this functioning mode it is possible to carry out the reference operations in order to use the scale for counting pieces When the functioning mode is selected one is asked to set some parameters uM APW unit of measure of the average piece weight APW Press ENTER PRINT to enter the step With the ZERO or TARE keys select the unit of measure g kg t Lb Confirm with ENTER PRINT Press many times the C key until the display shows the message SAVE e Press ENTER PRINT to confirm the changes made or another key to not save Independently from the selected unit of measure the APW has always three fixed decimals WAit t sampling interval Setting of the sampling time in seconds
41. disabled when the list of weighs is enabled Avalaible data in the list of weighs The data stored in the list of weighs include progressive number of the weigh number of the scale or indication of the text SUM indication of the closure of the list in the printing of the list it is marked with an asterisk next to the number of the scale or next to the text SUM in the last weigh stored date and time net weight equal to the gross weight also if the tare has been executed The tare value stored in the list of weighs is always equal to zero Steps of the management menu of the list PC Conn PC connection step by pressing the ENTER PRINT key the connection is activated the PC WAit message is displayed it is possible to download the list on PC with WeighConsole see the manual of the DiniTools software or one can send serial commands to the indicator to manage the memory see section FORMAT OF THE SERIAL COMMANDS TECH MAN REF if the list is empty the message EMPTY is displayed and the indicator is not connected to the PC Prn LSt List printing on the printer serial port the printed data are the same of the list that can be downloaded on PC through serial commands but without checksum for the description of the transmitted data see Command for reading the complete list of weighs stored in the memory TECH MAN REF By pressing the ENTER PRINT key the Print message is displ
42. during the sampling the display will indicate for an instant Error and the quantity put on the plate will not be accepted One should therefore use a higher reference quantity VARIABLE SAMPLE SIZE REFERENCE QUANTITY only for 17 key indicator It is possible to insert directly by keyboard any reference quantity up to 999999 not only the quantities proposed by the MODE key With the scale at zero after having stored a tare press F 5 the display will indicate n S and then 0 ora quantity already stored Modify and or enter the quantity up to 999999 using the numeric keys Follow the operations describe in point 5 in the COUNTING PROCEDURE section DISPLAY AND MODIFICATION OF THE AVERAGE PIECE WEIGHT only for 17 key indicator It is possible to view or enter a known Average Piece weight using the keyboard This can significantly speed up the reference operations With the scale at zero after having stored a tare press F 6 or the ENTER PRINT key at length The display will indicate APW and then 000 000 or a previously entered value expressed with three decimal digits in the programmed unit of measure Enter the APW value with the keyboard or leave the one present and press ENTER PRINT to confirm Example Unit of measure of the APW in g 000 000 means 000 000 g for example APW 001 050 1 05 g PRINTING IN THE COUNTING MODE If the presence of a printer has been configured e
43. e see the corresponding manual Notes If the memory is not initialized and one presses ENTER PRINT to store the weight the message Err Chk is displayed Date and time have to be set in the F ModE gt gt CLoCk step of the setup environment see the section DATE TIME ADJUSTMENT OPTIONAL OR INCLUDED DEPENDING ON THE MODEL 45 DFW series indicators DFW_03 12 07 EN U Storing of the weight and management of the list by pressing the ENTER PRINT key the current weight value is stored in the list it is also possible to store the sum of the weighs by pressing at length the ENTER PRINT key it is possible to access to the management menu of the list of weighs if the YES mode has been selected or one can directly activate the PC connection if the yES dir mode has been selected if the list closure is enabled and there is an open list of weighs by pressing at length the ENTER PRINT key the CLOSE message is displayed Press ENTER PRINT to confirm the display shows the totAL message and then the sum of the previous weights stored blinks for five seconds the instrument returns to weighing mode after these visualizations By pressing C the list is not closed and the next step of the menu is displayed itis possible to import the list of weights in WeighConsole see the manual of the DiniTools software which will display the list Note the printing function of the ENTER PRINT key is
44. e display the weigh information in sequence and scroll through it with the ZERO key ahead or the TARE key backwards e ch x in which x is the scale number always 1 e um yy in which yy is the unit of measure kg g to lb e gross weight for about a second the message GroSS appears and then the gross weight value e Tare weight for about a second the message tArE appears or tArEpt if it is a manual tare then the tare value appears Press C to return to weighing NOTES The alibi memory can store up to 131072 weighs then the rewriting takes place from the beginning If the alibi memory is empty when the MODE key is pressed the message EMPTY appears for about a second an error acoustic signal is enabled and one returns to weighing If the entered ID is not valid in other words if there is no stored weigh relative to the entered ID the message no id appears and an error acoustic signal is enabled and one returns to weighing INITIALISATION OF THE ALIBI MEMORY It is possible to cancel all the weighs made initialising the alibi memory this operation can be made directly on the indicator see the parameter SETUP gt gt ini AL of the set up environment TECH MAN REF or through the serial command see SERIAL COMMANDS below NOTES 48 DFW series indicators DFW_03 12 07 EN U It is not possible to just cancel a single weigh The initialisation is possible only with a non appro
45. e follows parameters toto tot S gt Min WGt 000 000 D a MAX WGt 1 000 000 y MAX tot x 00 D Tot Mod ae MAnuAL gt gt Auto D N WEiGh C 1 no D Lp 1 Yes gt gt FrZ tot gt no Yes D Wait St 1 000 D p CPS tAr gt C 1 no pC 1 Yes Min WGt MINIMUM WEIGHT TO ACCEPT FOR TOTALIZE Minimum weight that must be present over the load receptor in order to totalize MAX WGt MAXIMUM WEIGHT TO ACCEPT FOR TOTALIZE Maximum weight that must be present over the load receptor in order to totalize MAX tot NUMBER OF CONSECUTIVE TOTALISATIONS AFTER WHICH THE TOTAL IS AUTOMATICALLY PRINTED AND RESET After having carried out the set weighs the accumulated general total is printed and reset set a value between 0 and 63 NOTE the value 0 disables the function tot Mod TYPE OF TOTALISATION MANUAL or AUTOMATIC This step allows to set the type of totalization manual MAnuAL or automatic Auto with ZERO or TARE one changes the parameter with ENTER PRINT one confirms In the manual totalisation for each accumulation operation there is the display of the totAL message and then of the 54 DFW series indicators DFW_03 12 07 EN U weigh number and the net weight total before the printing of the data
46. e is a gross weight if the German French or Spanish language is selected in the print configuration 7 HAM Indicates the battery charge level see the section LOW BATTERY WARNING 8 MAX When viewing the metric information it identifies the indicated capacity range MIN When viewing the metric information it identifies the indicated minimum weigh range e When viewing the metric information it identifies the indicated division range 9 LT The locked tare is enabled 10 PT The manual tare is active 11 WI The instrument is in the first weighing range W2 The instrument is in the second weighing range W3 The instrument is in the third weighing range 12 Tetazzizaziza Indicate the number of the slave being displayed when in the SINGLE MULTISCALE REPEATER functioning mode In the other functioning modes scale nr 1 is always shown 27 DFW series indicators DFW_03_12 07_EN_U 13 PCS The number of pieces is being displayed 14 kg Indicates the unit of measure in use kg for kilogram g for gram 15 Indicates the percentage of the weight on the scale Sample Weight Percentile functioning mode 16 t Indicates the unit of measure in use tons 17 LB Indicates the unit of measure in use pounds 18 a These are displayed around the digits with higher sensitivity when viewing the weight x 10 19 Indicates that a key has been pressed 20 P
47. e serial port dedicated to the printer It turns the instrument on and off In the numeric input phase it quickly zeros the present value In the set up environment it allows to exit a step without confirming the change made F Fn It allows to select the desired function see section ADDITIONAL FUNCTIONS OF THE 17 KEY INDICATOR If pressed at length it allows to set the display intensity TECH MAN REF L int parameter The i key allows to view the scale s metric information capacity division minimum weigh for each configured range In the numeric input phase it allows to enter the decimal point NUMERIC KEYBOARD In the numeric input phase it allows to enter the desired value 26 DFW series indicators DFW_03_12 07_EN_U 8 SYMBOLS ON THE LCD DISPLAY The LCD display has symbols which show the indicator s functioning status you will find the description for each symbol below NUMBER SYMBOL FUNCTION 1 DIE The weight detected on the weighing system is near zero within the interval of 1 4 1 4 of the division 2 The weight is unstable 3 Ae The time is being shown on the display in the HH MM SS format 4 NET The displayed weight is a net weight 5 G The displayed value is a gross weight if the Italian or English language is selected in the print configuration 6 B The displayed valu
48. e to transmit the functionality of the ZERO TARE ENTER PRINT and C keys to the SLAVES If the connection is lost with the SLAVE which is acting as a repeater the MASTER will try to reconnect it if after about a second this does not happen it connects with the following SLAVE lf the connection is lost with a SLAVE in the sum mode the MASTER tries to reconnect it if this happens it remains in the sum mode otherwise it passes to the repeater mode of the following SLAVE 11 6 4 EXECUTION OF THE PRINTOUTS If there is a printer on the master the printer has to be selected both in the SLAVE and in the MASTER SEtuP gt gt SEriAL gt gt CoM Prn gt gt Pr ModE parameter TECH MAN REF it s possible to direct on it the printouts and the heading configured in the active slave by pressing on the MASTER or on the SLAVE the dedicated key depending on the selected function on the SLAVE In order to configure this format refer to section PROGRAMMING THE PRINTOUTS TECH MAN REF by pressing the ENTER PRINT key when the sum is displayed it is possible to execute a printout with the weighs of all the detected scales and their sum In order to configure this format refer to section PROGRAMMING THE PRINTOUTS TECH MAN REF the heading is the one programmed in the MASTER If there is a printer on a slave the printer has to be selected in the SLAVE SEtuP gt gt SEriAL gt gt CoM Prn gt gt Pr ModE parameter TECH MAN
49. eight present on the detected scales In the display of the sum The reference unit of measure is the one set in the SuM uM step If the sum of the weights is greater than 999999 the segments in the upper part of the display are turned on If the sum of the weights is less than 99999 the segments in the lower part of the display are turned on If the sum of weights is not valid because one or more slaves is in underload or overload the segments in the central part of the display are turned on and an acoustic signal is emitted It is possible to execute the manual or the semiautomatical tare of the sum in both cases the PT symbol on the LCD display is activated O If the MASTER indicator has a 17 key keyboard the functioning is the same as the preceding one Furthermore by pressing the numeric keys if just one slave is configured this is repeated also on the active slave in that moment if are configured from 2 to 9 slaves it is possible to directly select the desired SLAVE through the relative numeric key of the keyboard 1 E MASTER gt press the 1 key selection of SLAVE 1 if are configured 10 or more slaves it is possible to select the desired SLAVE by entering the corresponding number through the numeric keys and then pressing the ENTER PRINT key 1 E MASTER gt press the 1 key gt press the 0 key gt press ENTER PRINT gt selection of SLAVE 10 if has been set the value kb dFkr keyboard for DFWKR
50. en o do 29 9 3 LIMITATION OF THE TARE FUNCTIONS coi 30 OA RUTO POWER OFF FUNCTION clone ilari 30 9 5 LOW BATTERY WARNING ini ati olii ari ii ie 31 GUT DE WAC E E EET a ei ale ale an e a ie e E TT 31 9 7 MULTI RANGE FUNCTIONING for legal for trade approved instruments iii 31 9 9 REMOTE CONTROLA TON ds 32 9 8 1 FOUR KEY IR REMOTE CONTROL co cinaiainpeio 32 9 8 2 EIGHTEEN KEY IR REMOTE CONTROL cosita e tes 32 9 8 3 NINETEEN KEY IR REMOTE CONTROL pas o dedo elos ae 33 9 8 4 SIX KEY IRD REMOTE CONTROL le oca rara 33 9 9 DATE TIME ADJUSTMENT OPTIONAL OR INCLUDED DEPENDING ON THE MODEL 34 9 10 SCREEN SAVER FUNCTION OPTIONAL OR INCLUDED DEPENDING ON THE MODEL 35 Odds WE BOARD LOCK wee sussidio pesante 35 9 I2 PRINTING ta 35 9 13 REENABLING THE PRINTOUTS AND THE INDICATOR FUNCTIONS occicicccocccocoocococcononococncncocococonononncncni nana 36 914 DISPLAY OP METRIC DATA INFO cotarro todas 36 10 ADDITIONAL FUNCTIONS OF THE 17 KEY INDICATOR ccssssssssssssseseeeeeseeeeeeseeneneneesseneeeeeeeeeneneaeaneneneaeaseneneeeeas 37 10 1 STORED TARE MEMORY VALUES 5 Guia learned 37 10 2 ENTERING THE IDENTIFICATION CODE ss a ccrecta estirada rod 37 10 3 REPETITION OF THE LAST PRINTOUT MADE scroll patente bul ati alla AE 38 11 SELECTABLE OPERATING MODES _lcli allea 38 11 1 UNIT OF MEASURE POUNDS CONVERSION Std scat ote is s ccderalseucss eceeumtau aaa 39 TI ZNETNGROSS SWITCH GUS Ss a
51. ended string via the printer port ALL Std ALL EXt or PrPC Std PrPC EXt in Pr ModE parameter Executing printouts with NON approved scales In order to print with non approved scales the following conditions must exist the weight must be stable the gross weight must be gt 0 the printout is always active 35 DFW series indicators DFW_03 12 07 EN U NOTE In the totaliser mode in order to print the totalised weight the following must take place the weight must be stable the net weight must be gt of a division with normal or fast totalisation the net weight must be gt of 10 divisions with automatic totalisation the printing is reactivated depending on how the rEACT parameter has been set in the set up environment passage by zero of the NET weight weight instability or always see section REENABLING THE PRINTOUTS AND THE INDICATOR FUNCTIONS Legal for Trade scale printing In order to be able to print with a legal for trade scale the following conditions must exist the weight must be stable the net weight must be gt the minimum weight minimum of 20 divisions the printing is reactivated depending on how the rEACt parameter has been set in the set up environment passage by zero of the NET weight weight instability or always see section REENABLING THE PRINTOUTS AND THE INDICATOR FUNCTIONS Notes The printing is confirmed by the indication on the disp
52. ered as improper use of the equipment 4 DFW series indicators DFW_03_12 07_EN U The crossed out wheeled bin on the product means that at the product end of life it must be taken to separate collection or to the reseller when a new equivalent type of equipment is purchased The adequate differentiated refuse collection in having the product recycled helps to avoid possible negative effects on the environment and health and supports the recycling of the materials of which the equipment is made The unlawful disposal of the product by the user will entail fines foreseen by the current regulations DFW series indicators DFW_03_12 07_EN_U 2 MAIN TECHNICAL SPECIFICATIONS POWER SUPPLY MAXIMUM POWER OPERATING TEMPERATURE DISPLAYED DIVISIONS MAXIMUM INPUT SIGNAL MINIMUM VOLTAGE PER DIVISION RESOLUTION IN CALCULATION KEYBOARD PROTECTIVE CASE TARE FUNCTION AUTO POWER OFF LOW BATTERY WARNING BATTERY RECHARGE TIME LOAD CELL POWER SUPPLY LOAD CELL CONNECTIONS DFW 12Vdc trough 110 240 Vac 50 60Hz adapter and rechargeable battery 6 V 4 5 Ah DFWL 12Vdc through 110 240 Vac 50 60Hz adapter or 4 AA batteries not included DFWLB internal rechargeable battery nichel metal hydride 6 V 4 5 Ah recharger included DFWPM 4 AA batteries or trough PC with standard USB connector DFWLI 12Vdc trough 110 240 Vac 50 60Hz adapter DFWLIB internal rechargeable battery nichel metal hydride 6 V 4 5 A
53. f SEMIAUTOMATIC TARE the net weight before unloading the scale may also be 0 In case of MANUAL TARE or FROM DATABASE the net weight before unloading the scale must be greater than 2 divisions and stable To set the type of tare Turn on the indicator press the TARE while the firmware version is displayed the display shows the tyPE menu Press ZERO many times to scroll ahead through the parameters or TARE to scroll backwards until one finds the F ModE parameter 29 DFW series indicators DFW_03 12 07 EN U Press ENTER PRINT to enter the menu until one finds the tArE parameter and select it With the ZERO or TARE keys select the possible options LoCK locked tare unLoCK unlocked tare diSAb disabled tare Confirm with ENTER PRINT Press the C key many times until the display shows the message SAVE Press ENTER PRINT to confirm the changes made or another key for not saving In the 17 key indicator it is possible to carry out the selection also during the weighing if the tare has not been disabled by pressing in sequence the F 2 keys the display shows tA L LOCKED TARE is selected by pressing the same keys again the display shows tA U UNLOCKED TARE is selected The indicator stores the last selection made also after it is turned off 9 3 LIMITATION OF THE TARE FUNCTIONS With approved instrument it is possible to limit the tare functions by setting
54. for more than 60 seconds This message is shown for 3 seconds after that the instrument is turn off Er 11 Calibration error a too small sample weight has been used it is advisable to use a weight equal to at least half of the scale capacity Er 12 Calibration error the acquired calibration point tP1 o tP2 o tP3 is equal to the zero point tP0 Er 37 The number of converter points per scale division is less than two Carry out again the calibration with special attention to the capacity and the division Er 39 It is displayed when the instrument has not yet been calibrated and initialized Press the TARE key when the instrument displays Er 39 to enter the technical set up environment Carry out the initialization of the indicator dEFAu parameter and the selection of the type of keyboard kEyb parameter and finally the programming of all the parameters of the set up environment and the calibration 59 DFW series indicators DFW_03 12 07 EN U Er 85 It is displayed when the instrument has been initialized but not yet been calibrated Press the TARE key when the instrument displays Er 85 to enter the technical set up environment and carry out the calibration C Er 36 During the calibration some internal negative points have been calculated the calibration point is less than the zero point the signal is negative check the connections undEr the weight in underload i
55. gain without having reenabled the totalisation with the normal totalizer one can temporarily view on the display the number of weighs carried out and the PARTIAL NET TOTAL accumulated until that moment Subtotal if the accumulated digit is more than 5 digits the visualisation takes place in two stages with the fast totalizer the no 0 unS error message is displayed By pressing at length the MODE key one can display the partial net total the display shows the number of weighs the totAL message and then the total weight NOTE If the indicator is in the under load or over load status by pressing the MODE key the display shows the totAL message If the indicator remains in these conditions for 10 seconds the un oVEr error message is displayed if the weight reaches a value valid for the totalisation within 10 seconds the totalisation is executed 55 DFW series indicators DFW_03_12 07_EN U Inweighings mode not in SETUP environment it is possible modify quickly the following steps by pressing twice consecutively the MODE key toto tot S gt Min WGt gt 000 000 D gt MAX WGt At 000 000 D Ly MAX tot J gt 1 00 After having set these parameters by pressing ENTER PRINT into it to confirm the new value by pressing the C key it returns in the weighings mode status The values edited out the SETUP environment aren t s
56. ghing phase the keyboard is locked the LoC kEy message is displayed In this case it s only possible to turn off the instrument by pressing the C key for about 10 seconds and turn on the instrument By pressing the ZERO and ENTER PRINT keys in succession the keyboard is unlocked the unL kEy message is displayed If instead a different key is pressed the message PrESS ZEro to unLoCk is displayed when the ZERO key is pressed the message noW PrESS Print to unLoCk is displayed NOTE The keyboard may be disabled also by closing an input if programmed of the optional expansion board refer to the inPutS parameter of the set up environment TECH MAN REF in this case however when the keys are enabled or disabled the message LoCkEd does not appear on the display and upon pressing a key the display shows LoCkin for an instant 9 12 PRINTING If a printer is connected it is possible to print the programmed weight data for example 4heading lines of 24 characters GROSS weight TARE weight NET weight ticket number date and time optional or included depending on the model a CODE 39 bar code both with the LP542PLUS labeller as well as the TPR thermal printer Besides the generic printing described above each single functioning mode will have some specific printouts which are described in the operating mode It is also possible to send weigh data to the PC with standard or ext
57. h recharger included DFWPM 4 batterie tipo AA oppure tramite PC con connettore USB standard DFWLKR DFWLKRF internal rechargeable battery 6 V 1 3 Ah recharger included 230 Vac 50Hz 7 2 Vdc DFWLAP internal rechargeable battery 6 V 4 5 Ah recharger included 110 240 Vac 50 60 Hz 6Vdc DFWLID internal rechargeable battery nichel metal hydride 6 V 4 5 Ah recharger included 110 240 Vac 50 60 Hz 6Vdc DFWLIDCC 12Vdc tramite alimentatore 110 240 Vac 50 60Hz NOTE recharge the battery using ONLY the charger provided 5 VA From 10 to 40 C 14 to 104 F with even temperature 10000e 3X3000e for legal for trade use expandable to 800 000 for internal use with minimum signal coming from the 1 6mV V cell 6 mV V 0 3 uV approved instrument 0 03 uV non approved instrument 1 500 000 points with signal in input equal to 3mV V DFW water resistant polycarbonate membrane keys with tactile and acoustic feedback DFWL DFWLI DFWLIB DFWLKR DFWLKRF DFWPM DFWLAP DFWLID DFWLIDCC water resistant polycarbonate mechanic keys with tactile and acoustic feedback ABS console IP 65 protection for DFW IP 67 for DFWLAP IP 54 for DFWL STAINLESS STEEL console IP 68 protection for DFWLB DFWLI DFWLID and DFWLIDCC Available on the entire capacity Programmable from 1 to 255 minutes or disinserted Low Batt will appear on the display 12 hours 5Vdc 5 120Ma max 8 cells of
58. he data of the second and third range appear only if actually configured 10 ADDITIONAL FUNCTIONS OF THE 17 KEY INDICATOR 10 1 STORED TARE MEMORY VALUES It s possible to store up to 30 tare memory values identified by the location numbers 1 to 30 which the user can recall when needed To insert or modify a tare value press the keys F 9 in sequence the display will indicate t nn in which nn is the storage number to be entered For example by pressing 01 and then ENTER PRINT the display will indicate 00000 or any value that already exists in the tare memory location 01 Insert the tare value with the numeric keyboard with the C key one quickly zeros the entered value and press ENTER PRINT Repeat the sequence for the following memory positions The value must be entered as a multiple of the scale s minimum division RECALLING STORED TARE VALUES To recall a stored value Press the keys F 1 in sequence The display will indicate t nn in which nn is the storage number to be entered Press the keys corresponding to the desired tare value location in memory 01 30 and then ENTER PRINT the tare will be enabled 10 2 ENTERING THE IDENTIFICATION CODE It is possible to insert 2 numerical codes of up to 10 digits in length maximum to use as a reference during printing Press the F 3 keys in sequence The display will indicate Ild n in which n identifies the code
59. he display 8 By pressing the MODE key one switches from the display of the percentage to the display of the net weight and vice versa 9 Tocarry out a new sampling press at length the MODE key and repeat the operations as describe in point 3 Er Mot ERROR DUE TO WEIGHT INSTABILITY DURING THE SAMPLING It may happen that during the sampling phase the weight is unstable the Er Mot is shown remaining for about three seconds One should therefore repeat the sampling operation MINIMUM WEIGHT OF THE SAMPLE It is necessary to use a net weight greater than 0 VARIABLE PERCENTAGE QUANTITY only for 17 key indicator It is possible to insert directly by keyboard any percentage different from the ones proposed by the MODE key With the scale at zero after having stored a tare press F 5 the display will indicate n S and then 0 ora quantity already stored Modify and or enter the quantity max 3000 0 using the numeric keys Follow the operations describe in point 5 in the PROCEDURE section PRINTING If the presence of a printer has been configured each time ENTER PRINT is pressed while either weight or percentage are displayed one prints the data programmed in the SEtuP gt gt SEriAL gt gt CoM Prn gt gt Pr ConF of the set up environment TECH MAN REF for example GROSS weight TARE weight NET weight Percentage quantity on the scale in that moment NOTE If the sampling has not
60. he paragraph TILT DEVICE The storage of the weigh by pressing a key is possible only if the function is active net weight passed from 0 or weight instability or always depending on how the F ModE gt gt rEACt step has been configured in the technical set up TECH MAN REF the net weight is at least of 20 divisions with approved instrument If these conditions are not respected in the response to the PID serial command one has NO in the place of the ID there is no transmission if ENTER PRINT has been pressed When the weight is transmitted with the ID following the pressing of the ENTER PRINT key the display shows for about 2 seconds the message tr id and the transmitted string is the following lt ESC gt II PIDSS B LLLLLLLLLLUU YYTTTTTTTTTTUU ID NO lt STX gt See the following section Serial commands for the string description NOTES With approved or not approved instrument the storage of the weigh through the PID serial command is always possible for all the weighs from 0 to full range value READING OF THE WEIGHS CARRIED OUT In order to read the information relative to the weighs carried out Press the MODE key The message rew id appears now one should enter the rewriting number from 00000 to 00255 and press ENTER PRINT The message id appears now one should enter the weigh number from 000000 to 131072 and press ENTER PRINT Now it is possible to view on th
61. he remote control one returns to the weighing mode 9 8 4 SIX KEY RD REMOTE CONTROL If the model is provided for the 6 key remote control it is possible to remotely use the functionality of the ZERO TARE MODE ENTER PRINT C DEL and Fn keys To choose this type of remote control follow the below procedure Turn on the scale press the TARE key while the firmware version is displayed the display shows the typE menu Press ZERO many times to scroll ahead through the parameters or TARE to scroll backwards until one finds the F ModE parameter Press ENTER PRINT to enter the menu 33 DFW series indicators DFW_03_12 07_EN U Scroll until one finds the ir ConF parameter and select it With the ZERO or TARE keys select the possible options none disabled remote control rd 1 and rd br 1 all the remote control keys function as the TARE key or rd 6 and rd br6 the remote control keys functions as ZERO TARE MODE ENTER PRINT C DEL and Fn All other options refer to other types of remote controls Confirm with ENTER PRINT Press the C key various times until the message SAVE appears on the display Press ENTER PRINT to confirm the changes made or another key to not save The remote control keys repeat the keys functions both the ones obtained with a SHORT pressing as well as those with a LONG pressing and they correspond to the following indicator keys
62. hing without saving the changes made Confirm with the ENTER PRINT key the value will be subtracted from the weight present on the plate and the relative pilot lights will turn on With the 17 key indicator 1 type in the desired value through the numeric keys depending on the model press i or to enter the decimal point NOTE In the MASTER press the numeric 0 key and digit the desired value through the numeric keys 2 confirm with TARE key NOTE If the entered value is not a multiple of the scale s minimum division it will be rounded off CANCELLING A TARE One can manually cancel the tare value in different ways unload the scale and press the TARE only if the net weight is equal to zero and not negative or ZERO key carry out the tares in subtraction partially unloading the scale and and press TARE to zero the display press C without unloading the scale enter a manual tare equal to 0 NOTE it is possible to automatically cancel the tare value see the following section LOCKED UNLOCKED DISABLED TARE SELECTION Normally when a tare value is entered automatic manual or from storage by unloading the scale plate the display shows the tare value with a negative sign LOCKED TARE For one s convenience it is also possible to choose that the tare value cancels itself automatically each time that the scale is unloaded UNLOCKED TARE or disable the tare functions With the UNLOCKED tare In case o
63. icates d1 L CODE 1 LOCKED Repeat the same operations for CODE 2 10 3 REPETITION OF THE LAST PRINTOUT MADE Press in sequence the F and PRINT keys the last printout made by the indicator will be repeated NOTES By turning off the instrument the information relative to the last printout made will be lost therefore this function is not enabled until the first printout is made This function is avalaible only in the DFW type indicators 11 SELECTABLE OPERATING MODES In addition to the STANDARD weighing mode with TARE subtraction and transmission of data the indicator can carry out one of the following functions UNIT OF MEASURE POUNDS CONVERSION NET GROSS SWITCH SET POINT ON THE GROSS WEIGHT SET POINT ON THE NET WEIGHT IN OUT SINGLE MULTISCALE REPEATER ALIBI MEMORY TOLERANCE CHECK SAMPLE WEIGHT PERCENTAGE SINGLE SCALE REPEATER DISPLAY WITH SENSITIVITY X 10 FREEZING OF THE WEIGHT ON THE DISPLAY PEAK DETECTOR HORIZONTAL TOTALIZER VERTICAL TOTALIZER PIECE COUNTING If using the DFWPM version one should set the SINGLE MULTISCALE REPEATER functioning mode Each functioning mode foresees the turning on of various function pilot lights described in detail in the sections KEYS AND INDICATORS OF THE FRONT PANEL and SYMBOLS ON THE LCD DISPLAY To set the operating mode carry out the following procedures Turn on the scale press the TARE key while the firmware version is displayed the display
64. icator s various functioning modes the keys functions and the display indications It is possible that one may incur into the phrase TECH MAN REF this means that an advanced function is being described therefore for the technical personnel and which is further explained in the corresponding technical manual We advise to carefully follow the instructions for programming the weight indicator by taking actions not indicated this manual one could cause the scale to not work properly In addition to having all the characteristics of a high precision scale the indicator has the unit of measure pounds conversion function the gross weight net weight conversion set point on gross weight or net weight in out weigh single multiscale repeater alibi memory tolerance check sample weight percentage freezing the weight on the display peak detector weighs totaliser and piece counter The indicator adapts itself to normal weighing applications in either industrial settings such as during factory production processes or that of commerce such as legal for trade applications also satisfying the frequently needed ability to transmit and print the data through its two bidirectional serial ports This manual has been made as carefully and exactly as possible in any case your suggestions are always A N WARNING IN Any attempt to repair or alter the unit can expose the user to the danger of electric shock and it will void our warrant
65. instruments in the step FunCt gt gt MAStr gt gt nuMSL gt gt t KEyb by pressing the numeric keys it is possible to select the corresponding scale if the sum of weights is displayed select the corresponding platform if the weight of a slave is displayed 43 DFW series indicators NOTE the functionality of the MODE key is the same as the preceding way DFW_03_12 07_EN_U MASTER KEY MAP Pressed key 3590 key CPWE key DGT key ZERO ZERO F6 ZERO TARE TARE TARE TARE MODE RIGHT ARROW FQ MODE ENTER ENTER ENTER ENTER C C C C 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 0 0 0 0 POINT SHIFT POINT NA FN F1 F1 F NA not available key WARNING To carry out the weight repeater function it is enough that just one SLAVE instrument in the system be turned on When turned on the MASTER places itself automatically on the first turned on SLAVE lowest 485 address if all the instruments are off or if the radio signal does not reach the MASTER on the same display the ECo n message is displayed in which n is the address of the SLAVE with which one is trying to communicate If there are various slaves it isn t possible to transmit the functionality of the MODE key to the active slave To carry out the sum function it is necessary to have a connection with at least two SLAVES Inthe sum mode it isn t possibl
66. is the rewriting number 5 digits from 00000 to 00255 and YYYYYY is the weigh number 6 digits from 000000 t0 131072 dd mm yy Date in the dd mm yy format only with PIDD command bb 2 space characters 32 decimal ascii character only with PIDD command hh mm ss Time in the hh mm ss format only with PIDD command In the case in which the gross weight is negative or unstable the weight is transmitted but not the ID NO is in its place In these cases there is no storage in the alibi memory In the case in which the date time is not detected or set the weight is transmitted but not the date and time NO DATE TIME is in its place WEIGH READING Command INALRDXXXXX YYYYYY lt CR o CRLF gt In which II 485 address only when transmitting in 485 mode XXXXX rewriting number from 00000 to 00255 YYYYYY weigh number from 000000 to 131072 49 DFW series indicators DFW_03 12 07 EN U Instrument response IB LLLLLLLLLLUU YYTTTTTTTTTTUU lt CR o CRLF gt In which II 485 address only when transmitting in 485 mode B scale number always 1 LLLLLLLLLL gross weight on 10 digits UU unit of measure YY spaces in the case of null or semiautomatic tare PT in the case of manual tare TTTTTTTTTT tare weight on 10 digits ALIBI MEMORY CANCELLATION only with non approved instrument Command INALDL lt CR o CRLF gt In which II 485 address only when transmitting in the 485 mode Instrument response
67. ivision Indicates that the weight is unstable Indicates that the displayed value is a net weight Indicates the unit of measure in use and that one is in the first weighing range Indicates the unit of measure in use and that one is in the second weighing range Indicates that a specific function of the indicator is active 25 DFW series indicators DFW_03_12 07_EN_U SCALE KEY FUNCTION ZERO Zeros the displayed gross weight if it is within 2 of the total capacity Cancels the negative tare value When entering numbers it decreases the digit to be modified TARE If pressed for an instant it carries out the semiautomatic tare If pressed at length it allows entering the manual tare from keyboard Cancels the negative tare value In the numeric input phase it increases the digit to be modified MODE It carries out a specific function of the operating mode set in the set up environment In the numeric input phase it selects the digit to be modified from left to right In totalizator modes if pressed twice consecutively it allows to enter in a specific menu to set the parameters of the totalizations ENTER PRINT It carries out a specific function of the operating mode set in the set up environment In the numeric input phase it confirms the entry made In the SET UP it allows to enter a step or to confirm a parameter within a step It transmits the data from th
68. ivision is enabled At this point the first range division is restored only by passing by the gross zero of the scale The selection of the range number with multirange functioning is made during the indicators calibration TECH MAN REF 31 DFW series indicators DFW_03_12 07_EN U 9 8 REMOTE CONTROL OPTIONAL If the model is supplied for the remote control it is possible to remotely control the instrument through four different remote controls 4 key infrared ir remote control 18 key infrared ir remote control 19 key infrared ir remote control or 6 key radio rd remote control 9 8 1 FOUR KEY IR REMOTE CONTROL NOTE indoor use only If the model is supplied for the 4 keys remote control it is possible to remotely use the functionality of the ZERO TARE MODE ENTER PRINT keys or just the TARE key To choose which type of functioning follow the below procedure Turn on the scale press the TARE key while the firmware version is displayed the display shows the typE menu Press ZERO many times to scroll ahead through the parameters or TARE to scroll backwards until one finds the F ModE parameter Press ENTER PRINT to enter the menu Scroll until one finds the ir ConF parameter and select it With the ZERO or TARE keys select the possible options none disabled remote control ir 1 all the remote control keys function as the TARE key or ir 4 the remote control keys function
69. kly zeros the entered value by pressing C again one cancels the entry and returns to weighing Confirm with ENTER PRINT the display shows first t Min then 000000 or the T1 lower tolerance previously used With the keyboard enter the desired lower tolerance with C one quickly zeros the entered value by pressing C again one cancels the entry and returns to weighing Confirm with ENTER PRINT the display shows first t MAX then 000000 or the T1 upper tolerance previously used With the keyboard enter the desired upper tolerance with C one quickly zeros the entered value by pressing C again one cancels the entry and returns to weighing Confirm with ENTER PRINT the display shows first thrESh and then 000000 or the enabling threshold used previously Through the keyboard enter the desired enabling threshold by pressing C one quickly clears the entered value while by pressing again C one cancels the entry and returns to the weighing mode Confirm with ENTER PRINT the display shows StorE for an instant after this it returns to weighing NOTES If the entered value is wrong i e tolerance value greater than the target or target greater than the scale capacity the indicator emits a prolonged sound and zeros the entered value furthermore if a value different than the scale division is 50 DFW series indicators DFW_03 12 07 EN U entered it is rounded off to the nearest minimum division multiple
70. lay functioning mode has not been configured the prolonged pressure of the ENTER PRINT key has no effect The DISABLING SET POINT must be equal or less than the ENABLING one if in the DISABLING SET POINT one enters and confirms a value greater than the ENABLING one the instrument will automatically set the same value in the ENABLING step and the anomaly is indicated through the ModiFy message at the exit of the configuration MENU of the SET POINTS If in the ENABLING SET POINT one enters a value lower than the DISABLING one the instrument does not allow to confirm if one enters a set point with a number of divisions not coherent with the set minimum division it will be rounded up to the multiple of the minimum division closest to it The 0 value is valid for the enabling and the disabling of set points and just the set points greater or equal to zero are accepted The check of the weight remains active on the present value even during the modification of the SET POINT until the new value is confirmed At start up the relays are managed from when the weight is displayed and these take on the configuration set in the set up environment These are not managed inside the technical set up The tare operations are active MODE WITHOUT HYSTERESIS It is the same as the functioning mode with hysteresis except that one enters just one SET POINT value therefore the enabling threshold coincides with the disabling threshold 11 4 SET POINT ON
71. lay of the Print message or tot in case of totalisation If the printout is not reenabled the display shows the no 0 unS message With the weight unstable the display shows the unStAb message If the gross or net weight is less than the requested minimum weight by pressing the ENTER PRINT key the display shows the LoW error message If the indicator is in under load or over load status by pressin the ENTER PRINT key the display shows the un oVEr error message To configure the printouts go to the section PROGRAMMING THE PRINTOUTS in the technical manual TECH MAN REF 9 13 REENABLING THE PRINTOUTS AND THE INDICATOR FUNCTIONS While using the indicator it is possible to incur into the no 0 unS error shown on the display along with an acoustic signal this means that the printing or the function which one wants to carry out must be reenabled in order to avoid unwanted executions It is possible to set the reenabling in different ways passage by zero of the net weight weight instability or always Follow the procedure below Turn on the scale press the TARE key while the firmware version is displayed the display shows the tyPE menu Press ZERO many times to scroll ahead through the parameters or TARE to scroll backwards until one finds the F ModE parameter Press ENTER PRINT to enter the menu Scroll until one finds the rEACt parameter and
72. n battery depending on the instrument model 6V RECHARGEABLE BATTERY FEATURES Material Lead Power 4 5Ah Output 6V For DFWLB DFWLIB DFWLID 6V RECHARGEABLE BATTERY FEATURES Material NiMH Power 4 3 Ah Output 6V THE BATTERY MUST ONLY BE REPLACED WITH AN ORIGINAL FROM THE MANUFACTURER In order TO POWER the instrument through the 110 240Vac mains or TO RECHARGE the 6V battery e EXTERNAL power adapter insert the plug end of the AC DC power adapter into the socket or terminal board in the back of the instrument chapter INSTALLATION and the adapter in your main current source e INTERNAL power adapter insert the power supply cable in your main current source The DFWL model can be powered also with 4 AA rechargeable or not rechargeable batteries which have to be inserted in the extractable battery box NOTE if the AA rechargeable batteries are used not supplied the recharge MUST be made separately using the proper battery charger not supplied TO INSERT OR REMOVE the AA batteries pull out the battery box which is found on the upper side of the instrument chapter INSTALLATION remove the discharged batteries and insert the new ones according to the shown polarity then insert the battery box again If the instrument has been powered correctly the power on led on the front panel turns on Do not connect other equipment to the same socket as the one that the adapter is in Do not step on or crush the power supply
73. number which one wants to enter Press 1 or 2 the display will show 00000 or the last entered value Enter the code through the numeric keyboard and confirm with ENTER PRINT or press C to exit without saving the modifications During the entry just the last 6 digits entered will be displayed in any case it is possible to scroll all the digits using the MODE key After its entry the code will automatically be printed with its abbreviation ID1 or ID2 in each printing that will be made The non significant zeros are not printed It is also possible to set the automatic cancellation of the code after the printing is made IN ANY CASE the stored codes are cancelled when the instrument is turned off NOTES The values between 0 000 000 001 and 9 999 999 999 are valid by entering 0 000 000 000 the code is cancelled Inthe TOTALIZER functioning mode the codes will be printed only in the printing of the total LOCKED UNLOCKED CODE SELECTION Normally the code is LOCKED in other words once it is set it remains stored and therefore printed until it is cancelled or 37 DFW series indicators DFW_03 12 07 EN U until the instrument is turned off In any case it is possible to make it so the code is cancelled as soon as it is printed UNLOCKED CODE Press the keys F 4 in sequence the display indicates Mld n Press 1 the display indicates ld1 U CODE 1 UNLOCKED Press the same keys again the display ind
74. o the 110 240 Vac mains voltage Safety norms must be respected for the connection to the mains voltage including the use of a line which has to be free from noise generated by other electronic equipment It is also possible to power through a rechargeable built in battery depending on the instrument model 6V RECHARGEABLE BATTERY FEATURES Material Lead Power 1 3 Ah DFWLKR DFWLKRF 4 5 Ah DFWLAP Output 6V THE BATTERY MUST ONLY BE REPLACED WITH AN ORIGINAL FROM THE MANUFACTURER In order TO POWER the instrument through the 110 240Vac mains or TO RECHARGE the 6V battery insert the plug end of the AC DC power adapter into the socket or terminal board in the back of the instrument chapter INSTALLATION and the adapter in the mains If the instrument has been powered correctly the power on led on the front panel turns on Do not connect other equipment to the same socket as the one that the adapter is in Do not step on or crush the power supply cable 5 2 DFW DFWLI DFWLIB DFWL DFWLB DFWLID DFWLIDCC POWER SUPPLY The instrument can be powered with a 12 Vdc tension supplied from an AC DC external or internal adapter depending on the model which should be connected to the 110 240 Vac mains voltage Safety norms must be respected for the connection to the mains voltage including the use of a line which has to be free from noise generated by other electronic equipment It is also possible to power through a rechargeable built i
75. onn step and press ENTER PRINT Example of connection to the PC DFWPM10USB MASTER connected to PC PC SEL parameter set to 2 TECH MAN REF If the yES mode has been selected the indicator communicates by radio with the PC on the serial port 2 in this case a radio module has to be connected to the PC If the yES dir mode has been selected the indicator communicates with the PC on the serial port 1 the connection between indicator and PC has to be made directly through a USB cable 11 6 6 TURN OFF THE MASTER AND THE SLAVES If the MASTER displays the sum of the weights by pressing at length the C key on the MASTER it is possible to turn off only this indicator by pressing at length the C key on a SLAVE itis possible to turn off only that indicator after a few instants the MASTER displays the ECo n message in which n is the number of the SLAVE that has been turned off and then the weight transmitted by the next detected SLAVE If the MASTER displays the weight transmitted by a SLAVE by pressing briefly the C key on the MASTER this is repeated on the active SLAVE by pressing the C key on the MASTER until the OFF message is displayed it is possible to turn off the active SLAVE the OFF message is displayed on the MASTER for a few seconds then it displays the ECo n message in which n is the number of the SLAVE that has been turned off and then the weight transmitted by the
76. possible next detected SLAVE Note while the OFF message is displayed it is possible to turn off the MASTER by pressing again at length the C key by pressing the C key on the MASTER until the OFF message is displayed for the second time it is possible to turn off only the MASTER indicator by pressing at length the C key on the active SLAVE it is possible to turn off only that indicator the MASTER displays the OFF message and then the ECo n message in which n is the number of the SLAVE that has been turned off then the MASTER displays the weight transmitted by the possible next detected SLAVE by pressing at length the C key on a SLAVE that is not active it is possible to turn off only that indicator It is also possible to turn off only the MASTER indicator while it displays the ECo n message by pressing at length the C key If the auto off is set on MASTER indicator it works only while the MASTER indicator displays the ECo n message 11 7 ALIBI MEMORY ALibi OPTIONAL The alibi memory allows to store the transmitted weight values in the computer for data processing and or integration The stored values may then be recalled from the PC serial line or directly on the indicator s display for a following check The storage of a weigh takes place either following the reception of the serial command or following the pressure of the ENTER PRINT key the indicator transmits on the PC serial line the gro
77. proved instrument or LEGAL in case of approved instrument the g gravity value and finally it executes a countdown self check TO RESTART the instrument keep the C key pressed for 8 seconds long the indicator will turn off then release the key and the indicator will automatically turn on TO TURN OFF the instrument keep the C key pressed until the OFF message appears on the display then release the key DFW series indicators DFW_03_12 07_EN U 6 FRONT PANEL KEYS AND INDICATORS 5 key version The front panel of the indicator is designed for quick and simple weighing applications It consists of a display with 6 digits 25 mm in height 7 LED indicators depending on the model and a 5 key water proof film keyboard If the indicator has an LCD display while weighing various multifunction symbols indicating the functioning status will turn on see section SYMBOLS ON THE LCD DISPLAY DFW LCD DISPLAY VERSION de aN aN a FUN LI DO DFW LED DISPLAY VERSION DFW series indicators DFW_03_12 07_EN_U a w e kay e DFWLI DFWLIB PLAY MOBILE DINI ARGEO YOO DFWPM 20 DFW series indicators DFW_03_12 07_EN_U DFWLAP 2 Me e a lt DFWL DFWLB 21 DFW series indicators DFW_03_12 07_EN_U GIO CIO COs VN e E G DFWLID DFWLIDCC Indicates the presence of power supply Sensor for the reception of the remote control signal Indicates that the weight detec
78. quence in the 17 key indicators or the key MODE in the 5 key indicator the display shows b SeNS b out and then StorE to disable the function press again the keys F and 6 or MODE in sequence the display shows MutE and then StorE TECHNICAL NOTES The 0 value is valid for the tolerances and for the activation threshold as well By setting the target at 0 the weight check is disabled If the printer has been configured and a target greater than 0 has been set the target tolerances and check result will be printed The check of the weight is active also during the modification of the target and the tolerances according to the last confirmed values The new entered values start working after having been confirmed The 4 relays of the 2 expansion boards optional are automatically enabled depending on the mode selection and may be used to manage external signals which show the operator whether the weight on the scale is INSUFFICIENT CORRECT ABUNDANT in comparison to the TARGET WEIGHT Furthermore it is not possible to set the functioning mode of the relays but just the status NO NC and the type of check direct or upon stability Itis possible to set the target the tolerances and the activation threshold through the serial line see section FORMAT OF THE SERIAL COMMANDS TECH MAN REF 11 9 SAMPLE WEIGHT PERCENTAGE PErC In this operating mode the instrument shows on
79. ro With approved instrument the d SALE and rEM dSP steps are read only 9 4 AUTO POWER OFF FUNCTION It is possible to automatically turn off the indicator from 1 to 255 minutes or disable it the auto power off takes place when with unloaded scale the weight has not been moved or a key has not been pressed for the time set the display shows the oFF blinking message and an acoustic signal is emitted after this the indicator turns off For the setting follow the procedures below Turn on the scale press the TARE key while the firmware version is displayed the display shows the tyPE menu Press ZERO many times to scroll ahead through the parameters or TARE to scroll backwards until one finds the F ModE parameter Press ENTER PRINT to enter the menu Scroll until one finds the En SAVE parameter and select it Scroll until one finds the AutoFF parameter and select it With the ZERO or TARE keys select the possible options diSAb auto switch off disabled EnAb auto switch off enabled Confirm with ENTER PRINT if EnAb has been selected one will be asked to enter the number of minutes after which 30 DFW series indicators DFW_03 12 07 EN U the indicator should turn off enter a number between 1 and 255 using the MODE key to select the digit to be modified and ZERO TARE to decrease increase it and confirm with ENTER PRINT Press many times the C key until the di
80. s as ZERO TARE MODE and ENTER PRINT All other options refer to other types of remote controls Confirm with ENTER PRINT Press the C key many times until the message SAVE appears on the display Press ENTER PRINT to confirm the changes made or another key to not save In the multifunction configuration the remote control keys repeat the keys functions both the ones obtained with a SHORT pressing as well as those with a LONG pressing and they correspond to the following indicator keys KEY none MODE FUNCTION ir 1 MODE FUNCTION ir 4 MODE FUNCTION ZERO DISABLED TARE ZERO TARE DISABLED TARE TARE F1 MODE DISABLED TARE MODE F2 PRINT DISABLED TARE ENTER PRINT In the multifunction configuration by pressing at length the ZERO key it s possible to put the instrument in stand by by pressing the C key on the keyboard or by pressing at length any key on the remote control one returns to the weighing mode 9 8 2 EIGHTEEN KEY IR REMOTE CONTROL NOTE indoor use only If the model is provided for the 18 key remote control it is possible to remotely use the functionality of the ZERO TARE MODE ENTER PRINT Fn C DEL and numeric keys To choose this type of remote control follow the below procedure Turn on the scale press the TARE key while the firmware version is displayed the display shows the typE menu Press ZERO many times to scroll ahead through
81. s possible to set the status of the relays normally open or normally closed or the type of check direct or weight stability MODE WITH HYSTERESIS One enters two SET POINTS for each relay a DISABLING one which when the gross weight is lower than it it disables the concerned relay and an ENABLING one which when the gross weight is equal or greater than it it enables the concerned relay By keeping the ENTER PRINT key pressed for about 3 seconds one enters the DISABLING and ENABLING SET POINT values only for the configured relays The display shows S1 oF DISABLING relay 1 SET POINT press ENTER PRINT to enter the step Use the MODE key to choose the digit to be increased BLINKING DIGIT the scrolling of the digits goes from left to right Decrease or increase the value using the ZERO or TARE keys When finished entering the values confirm with ENTER PRINT The display shows S1 on ENABLING relay 1 SET POINT enter the weight value like in the preceding SET POINT and confirm with ENTER PRINT With the C key one quickly zeros the set point value Inthe same way go ahead with the Sb2 0F Sb2 on Sb3 0F Sb3 on Sb4 0F Sb4 on if present Once finished the programming of the set points one should exit with the C key to return to weighing 39 DFW series indicators DFW_03 12 07 EN U RELAY 1 STATUS ENABLED DISABLED NOTES Sb1 0F Sb1 0n GROSS WEIGHT If the re
82. select it With the ZERO or TARE keys select the possible options ZEro passage by zero of the net weight nSt instability ALWAYS Confirm with ENTER PRINT Press the C key many times until the message SAVE is shown on the display Press ENTER PRINT to confirm the changes made or another key to not save 9 14 DISPLAY OF METRIC DATA inFO The indicator is fitted with a function named INFO thanks to which it is possible to view the configuration metric data With the 5 key indicator keep the C key pressed until the display shows inFO and release or press the keys MODE C keys in sequence With the 17 key indicator depending on the model press the key i once or press the keys MODE C keys in sequence or keep the C key pressed until the display shows inFO and release 36 DFW series indicators DFW_03 12 07 EN U The capacity value of the first range will appear Press the ZERO key to scroll the following data in this order Capacity 1 range gt Minimum weigh 1 range gt Division 1 range gt Capacity 2 range gt Minimum weigh 2 range gt Division 2 range gt Capacity 3 range gt Minimum weigh 3 range gt Division 3 range gt Capacity 1 range gt Press the TARE key to scroll backwards the metric data Press the C key to return to weighing NOTES The minimum weigh corresponds to 20 net weight divisions T
83. splay shows SAVE Press ENTER PRINT to confirm the changes made or another key for not saving NOTE If the indicator is in master mode the autoff parameter only works when the display shows eco n 9 5 LOW BATTERY WARNING DFW model The indicator is able to recognize whether it is powered from the mains or through a battery DFWL DFWLB DFWLI DFWLIB DFWLID DFWPM DFWLKR DFWLKRF and DFWLAP models One should set the supply mode setting the step SEtuP gt gt ALiM If the indicator has the LCD display the charge level is shown in the weighing phase through the battery symbol man battery is charged m gt battery is partially charged 17 battery is discharged connect the indicator to the mains in order to recharge the battery if supplied or replace it Furthermore for a few seconds the Low bat message appears on the display minimum level voltage When recharging the battery if supplied the indicator shows the recharging phase below RECHARGING PHASE _ gt S gt Milli RECHARGE IS COMPLETED Al NOTES While recharging the instrument can be used as usual The instrument automatically turns off when the voltage goes below the minimum level It s possible to view the recharge percentile of the battery by pressing the ZERO key upon start up see the section POWER SUPPLY AND START UP 9 6 TILT DEVICE The TILT is a device which inhibits the indicator s weighing system and st
84. ss and tare weights and an ID which clearly identifies the weigh The ID has the following format lt Rewriting number gt lt Weigh number gt Rewriting number number of 5 digits which may go from 00000 to 00255 it indicates the number of complete rewritings of the alibi memory Weigh number number of 6 digits which may go from 00000 to 131072 it indicates the weigh number in the current rewriting of the alibi memory With each storage the weigh number is increased of 000001 when this reaches the 131072 value it restarts from 000000 and the rewriting number increases of 00001 Therefore the weigh relative to an ID may be verified just if it has a rewriting number equal to the current one of the alibi memory and a weighing number equal or less than the last value received with the PID command it has a rewriting number equal or greater than zero but less than 1 in comparison to the current value of the alibi memory and a weigh number greater than the last value received with the PID command 47 DFW series indicators DFW_03 12 07 EN U Example If the stored weigh is the following PIDST 1 1 000kg 1 000kg 00126 131072 and the following will be PIDST 1 1 000kg 1 000kg 00127 000000 The storage of a weigh is possible only if the weight is stable and valid in other words not in underload nor in overload if the gross weight is equal or greater than zero and without the TILT alarm see t
85. st condition in other words with all the central segments of the display turned on When the serial string of the connected instrument is identified the indicator repeats the data of the display or the weight string of the instrument to which it is connected CAREFUL The keys pressed in the REPEATER are not repeated on the TRANSMITTER and vice versa The indicator acts as a simple weight repeater only the C ON OFF key is enabled for turning on off Example of Dini Argeo REPEATER TRASMITTER configuration FunCt PCModE bAud bit REPEATER rEPE rEPE 6 9600 n 8 1 TRANSMITTER rEPE 6 9600 n 8 1 all functions except MAStr 11 11 DISPLAY WITH SENSITIVITY X 10 ViSS TO BE USED IN TESTING DURING THE CALIBRATION By pressing the MODE key one switches from the weight display with normal sensitivity to a sensitivity ten times greater in fact one will note that the last digit on the right of the display will have a sensitivity equal to the scale s division divided by 10 The printout can only be done when the indicator has the standard sensitivity TAKE NOTE In case the instrument is LEGAL FOR TRADE when MODE is pressed the sensitivity times 10 is displayed for five seconds after which the instrument returns to standard weight displaying Furthermore if the direct sales has been configured in the SEtuP gt gt d SALE parameter TECH MAN REF this displaying is possible only with if
86. ted by the weighing system is close to zero within of the division Indicates that the weight is unstable Indicates that the displayed value is a net weight Indicates the unit of measure in use and that one is in the first weighing range Indicates the unit of measure in use and that one is in the second weighing range Indicates that a specific function of the indicator is active SCALE KEY FUNCTION Zeros the displayed gross weight if it is within 2 of the total capacity ZERO Cancels the negative tare value When entering numbers it decreases the digit to be modified It allows scrolling ahead inside the menu steps or in the parameters within a step If pressed for an instant it carries out the semiautomatic tare TARE If pressed at length it allows entering the manual tare from keyboard Cancels the negative tare value In the numeric input phase it increases the digit to be modified It allows scrolling backwards in the menu steps or in the parameters within a step 22 DFW series indicators DFW_03_12 07_EN_U MODE It carries out a specific function of the operating mode set in the set up environment In the numeric input phase it selects the digit to be modified from left to right In totalizator modes if pressed twice consecutively it allows to enter in a specific menu to set the parameters of the totalizations ENTER PRINT It carries out a specific
87. ted with the date time board To totalize the net weight must be at least 1 division with non approved instrument and with normal or fast totalisation at least 10 division with non approved instrument and with automatic totalisation at least 20 divisions with approved instrument In normal and fast totalisations when the MODE key is pressed and the weight is not stable the blinking totAL message is displayed and the totalisation remains pending if the weight reaches the stability within 10 seconds the totalisation is executed otherwise the totalisation is aborted and the display shows the Error and unStAb messages in succession Furthermore also when the MODE key is pressed and the gross or net weight is less or equal to zero the blinking totAL message is displayed if the weight reaches a value valid for the totalisation within 10 seconds the totalisation is executed otherwise the display shows the Error and LoW messages in succession To avoid undesired accumulations the MODE key is active just once it reactivates depending on the setting of the rEACt parameter in the SET UP environment in other words either after passing by the net zero of the scale by instability or always see section REENABLING THE PRINTOUTS AND THE INDICATOR FUNCTIONS If the presence of a printer has been configured the MODE key causes also the printing of the weight values By pressing the MODE key a
88. tored permanently in the memory so if you want to store these values in the memory of the indicator you have to change they in the SETUP mode TOTALISATION WITH PRINTING If the presence of a printer has been configured upon each pressing of MODE one prints the data programmed in step SEtuP gt gt SEriAL gt gt CoM Prn gt gt Pr ConF of the set up environment TECH MAN REF for example Weigh number GROSS weight TARE weight NET weight PRINTING AND ZEROING OF THE TOTALS The instrument has two different total levels a partial total and a general total which increase upon each totalisation these may be printed and zeroed independently from each other To print and zero the PARTIAL TOTAL one should press for an instant the ENTER PRINT key depending on the type of totalisation various messages will be displayed With normal totalisation the number of weighs and the accumulated total will be displayed With fast or automatic totalisation the message totAL will be displayed The number of weighs made and the NET WEIGHT PARTIAL TOTAL are printed To print and zero the GENERAL TOTAL one should press for a few seconds the ENTER PRINT key With normal totalisation the G totAL message and then the number of weighs and the accumulated total will be displayed The number of weighs made and the NET WEIGHT GENERAL TOTAL are printed NOTE the data in any case may be printed until the following totalization
89. ufacturer for repair The WARRANTY is VOIDED if any of the following occurs repairs or attempted repairs are made by unauthorised personnel connected to equipment installed by others or is incorrectly connected to the power supply or instrument has defects or damage due to carelessness or failure to follow the guidelines in this instruction manual This warranty DOES NOT provide for any compensation for losses or damages incurred by the Customer due to complete or partial failure of instruments even during the warranty period AUTHORIZED SERVICE CENTRE STAMP 61
90. value disables this function In the SLAVES instead one needs enter a code between 01 and 32 to identify each single SLAVE in the step SEtuP gt gt SEriAL gt gt CoM PC gt gt PCModE gt gt 485 see set up environment TECH MAN REF 11 6 3 FUNCTIONING When turned on the MASTER predisposes itself for the connection to the SLAVES present ECo n message appears in which n is the SLAVE number which is to be detected if it has detected more than one SLAVE it shows the SuM message and then the sum of the weights of all the detected SLAVES if only one SLAVE is detected it positions itself on that scale a If the MASTER indicator has a 5 key keyboard by pressing the MODE key if just one slave is configured this is repeated also on the active slave in that moment if various slaves are configured one goes from SLAVE to SLAVE in order by 485 addresses the display shows SCA n in which n is the SLAVE number after this the weight transmitted by the selected SLAVE is displayed By pressing the ZERO TARE and ENTER PRINT keys on the MASTER these are repeated also on the active SLAVE in that moment It is possible to view the sum of weights present on all the detected scales also if lower than the number set in the F ModE gt gt FunCt gt gt MAStr gt gt nuMSL step as long as it is greather than 1 by pressing the MODE key pressed for a few seconds the display shows SuM and then the sum of the net w
91. ved instrument SERIAL COMMANDS Besides the commands described in the section FORMAT OF THE SERIAL COMMANDS TECH MAN REF in this functioning mode also the commands below are available WEIGH STORAGE Command INPID lt CRLF gt or lt ESC gt II PID lt STX gt INPIDD lt CRLF gt or lt ESC gt II PIDD lt STX gt in which Il 485 address lt ESC gt 27 ascii decimal character lt STX gt 2 ascii decimal character Instrument response to the II PID lt CRLF gt command IPIDSS B LLLLLLLLLLUV YYTTTTTTTTTTUU ID NO lt CRLF gt Instrument response to the lt ESC gt II PID lt STX gt command lt ESC gt II PIDSS B LLLLLLLLLLUU YYTTTTTTTTTTUU ID NO lt STX gt Instrument response to the II PIDD lt CRLF gt command IPIDSS B LLLLLLLLLLUV YYTTTTTTTTTTUU ID NO dd mm yybbhh mm ss NO DATE TIME lt CRLF gt Instrument response to the lt ESC gt II PID lt STX gt command lt ESC gt II PIDSS B LLLLLLLLLLUV YYTTTTTTTTTTUU ID NO dd mm yybbhh mm ss NO DATE TIME lt STX gt In which 1 485 address only when transmitting in 485 mode SS OL weight in overload or UL weight in underload or ST stable weight or US unstable weight or TL TILT input closed B scale number always 1 LLLLLLLLLL gross weight on 10 digits UU unit of measure YY 2 spaces in the case of null tare or semiautomatic tare PT in case of manual tare TTTTTTTTTT tare on 10 digits ID XXXX YYYYYY in which XXXXX
92. with a decimal greater is the time set and more precise will the calculated APW be e Press ENTER PRINT to enter the step e Set the desired time e Confirm with ENTER PRINT e Press many times the C key until the display shows the message SAVE Press ENTER PRINT to confirm the changes made or another key to not save COUNTING PROCEDURE 1 Place the empty container on the scale and press TARE to tare it 2 Check that the zero is on the display and press the MODE button the counting function is enabled 3 The display suggests a REFERENCE QUANTITY The possible options are 5 10 20 30 40 50 60 75 100 200 4 Press ZERO or TARE the number of times needed to reach the desired sample size 5 Put the quantity of pieces chosen for the SAMPLE on the scale and press ENTER PRINT to confirm or C to cancel the operation and return to weighing 6 Press ENTER PRINT the display will indicate SAMPL and the indicator will calculate the Average Piece Weight APW After a few instants the display will indicate the quantity selected put on the platform 7 Add the rest of the items to count in the container and whose value will appear on the display 8 Unload the scale the APW will remain stored in memory for the next counting of similar pieces without having to repeat the REFERENCE operation 9 By pressing the MODE key one switches from the display of the number of pieces to the display of the net weight and vice versa 1
93. y This instrument is covered under warranty provided that IT HAS NOT BEEN OPENED BY THE USER for any reason If any welcome problem with the unit or system has been experienced please notify the manufacturer or the dealer from which the instrument was acquired With the 6V rechargeable battery option it has to be completely recharged 12 hours in the first installation of the instrument we RECOMMEND disconnecting the battery if the instrument is not going to be used for more than 30 days In order to avoid the deterioration of the rechargeable battery In standard conditions never leave the battery partially or completely uncharged at least once a week recharge it completely In case the instrument is not used for a long period one needs to completely recharge the battery before the system is switched off for the last time recharge completely every 3 months Do not pour liquids on the indicator Do not use solvents to clean the indicator Do not expose instrument to either direct sun light or any heat sources Always mount the indicator and platform in a vibration free setting Read carefully amp apply what described in the POWER SUPPLY amp START UP section Do not install in an environment with any risk of explosion All the connections of the indicator have to be made respecting the rules applicable in the zone and in the installing environment Everything not expressly described in this manual has to be consid