Home

Frozen fat dissolving instrument

image

Contents

1. to 3 months can reduce the redundant fat layer thickness after two times of treatment can enhance the frozen fat dissolving operation but 1s not recommended for multiple randomized treatments 4 Frozen fat dissolving therapy is mainly directed against the local hypertrophy fat accumulation zone to design the physical health of people but not for the overall obesity mainly used for the treatment of a particular part such as the fat in the waist abdomen and back and other local fat Its treatment is not omnipotent not the treatment of obesity 1t cannot replace liposuction or other invasive treatment Substantial weight reduction should by eating a balanced diet and regular exercise frozen fat dissolving therapy can only carry extra fat elimination Skin antifreeze Treatment process in the application of qualified antifreeze when the temperature 1s lowered to 0 to 40 degrees to avoid frostbite consumables buy their own The treatment process 1 Treatment testing to see whether it 1s normal heart rate 50 100 2 Check the thickness of fat 3 Clean the treatment area area of hair removal treatment 4 Marking the treatment zone size 5 In the treatment of areas with antifreeze 6 At the treatment site paste antifreeze membrane 7 Patients undergoing treatment should sit so that the upper torso and thigh was 90 degrees 8 The cooling device to gently suck into the treatment site and setting the vacuum suctio
2. Frozen fat dissolving instrument WL 8039 The principle Frozen fat dissolving technology 1s gradually absorbed the subcutaneous fat calories Fat cells temperature are reduced to zero degrees Fahrenheit or they will be frozen Low temperature in the killing of fat cells without affecting the skin or muscle The death of fat cells followed by the liver is discharged in vitro Technology background Too much fat can influence a person s appearance and movement ability May also lead to various diseases Too much fatty tissue located in various parts of the body including the legs buttocks abdomen knee back arms and the other areas An excess of adipose tissue into cells may cause unsightly appearance Excess body fat was also associated with significant health risks have direct relation so we need effective methods to control or eliminate excess body fat Liposuction 1s a removing excess fat deposition of cosmetic operation process it can be a method to remove excess fat these treatments shortcomings that may be invalid or even in localized plastic slim Usually made of plastic surgery or dermatology special operation equipment to liposuction with an invasive method to the removal of subcutaneous adipose tissue Other non invasive manner such as by drugs diet exercise or a combination of these some cases is not possible to do For example when a person 1s injured or sick you cannot choose the regular exercise Similar
3. ly when weight loss pills or topical drug allergy or adverse reaction in addition the use of physical or system approach to weight loss you can eliminate the designated area of the fat body The cooling process using frozen fat dissolving operation is fundamentally different from other or minimally invasive manner and was approved as the most effective way to reduce fat This is a revolutionary new method since being put into use the fat reduction has been recognized as an important technical progress For those dieting exercise regularly but still need to eliminate local fat people frozen fat dissolving skill is definitely a great gift The fat concentration positions and less fat parts like love processing both sides and back fat the subtraction buttock top sides of the waist fat abdominal and back fat frozen fat dissolving operation can produce amazing results Especially in the low temperature fat 1s the triglyceride will be transformed into solid It uses advanced cooling technology through a gradual process of selective targeting of fat bulges and remove the fat cells this process can not harm the surrounding tissue reduce the redundant fat as the fat cells blasting of cooling will gradually reduce the thickness of a layer of fat forming a natural elimination process treatment of regional fat cells will slowly through the normal human the new supersedes the old To eliminate so as to remove excess fat Vacuum ha
4. n strength 9 Regulate the suction strength to the appropriate time maintain a constant suction suction can according to customer s ability to accept appropriate adjustment At the same time to meet the suction massage mode 10 Treatment of 25 30 minutes press the stop control keys stop suction screening and adding antifreeze 11 Repeat steps 10 to 11 until the completion of course again power off by pressing the start button After treatment After treatment of the skin may appear slight injury frostbite pigment careful nursing The matters needing attention 1 The equipment must be operated by professionals 2 Do not use without antifreeze 3 Patients with the use of the following medical electronic equipment cannot be used by the device The implantation of a pacemaker or other implantable electronic device To preserve the life of the artificial heart lung machine Portable electrocardiogram measuring equipment 4 Following patients in the use of machine before the professional doctor agree Patients with acute diseases Malignant tumor Patients with infectious diseases Pregnant women Patients with heart disease Patients whit a fever Being treated or those with physical anomalies in patients 5 Patients following the use of this device should be careful For babies and toddlers Sensory or physically impaired person Contraindications Liver problems Raynaud s di
5. ndle suction diagram Hole fore water outpute spillway hole gt a Fuse 4DKcavitation output Cryolipolysis Suction head Output 5Mhz RF outpu Hole fore water input Operation steps Step1 5Mhz multipolar RF set the working time about 10 15 minutes Choose the best RF intensity depends on the client s feelings Press the start and start get in the RF treatment Operated over return the main interface choose next function Step2 operate the cavitation handle set the working time about 10 15 minutes Choose the best intensity depends on the client s feelings Press the start and start get in the cavitation treatment Operated over return the main interface choose next function Cryolipolysis suction head Cryolipolysis suction head operate Hold the freezing film Gap along the bags open with her hands freezing film Operation steps S _ _ _ _ gt gt _ gt A gt d Cryotherapy Vacuum 7 nnn 40K Cavitation RF System E J Timer Intensity i W 7 F a Mode Intensit 2 RF System UP Timer Intensity Treatment set l Each part needs 30 60 minutes depending on the fat thickness and health 2 Only a portion of a part of the treatment of fat for example to eliminate the fat in the waist you need to complete a few courses 3 After a course of treatment and another one of the cooling process in the same position for 2
6. sease severe cold urticaria cold globulin hematic disease cold fiber hypoalbuminemia severe burns severe diabetes and older adults children frail and very resistant to freezing Technical parameters The host display 8 TFT color touch screen Power 500W Vacuum 650mmHg Pump flow 60L min Vacuum pressure 0 100Kpa Refrigeration temperature 0 C 5 degrees C 10 degrees C Burst fat frequency 35 40K Frequency 5MHz Working voltage AC220 230V 50Hz AC110 120V 60Hz Packing size 78 51 49CM Product introduction Security warning signs External identifier pause A Pause working A High voltage danger Electric flag ge A I Thank you for purchasing this product please read the user manual carefully before you use notes and keep for viewing at any time

Download Pdf Manuals

image

Related Search

Related Contents

GBC PB2600 User's Manual  Manuel d`utilisation    Microsoft Word - Service manual for LENNOX GC_H_M  SkyTraq GPS Viewer Software User's Guide  Sony VAIO VPCSA43FX  ViewSonic VS12618 User guide  sur votre propriété sur votre propriété sur votre propriété  MANUAL DE INSTRUCCIONES    

Copyright © All rights reserved.
Failed to retrieve file