esc 3800 leakage detector - Electronic Surveillance Corporation

image

Contents

1. An internal circuit reduces the preset delay times applicable to the body detect leakage path If the leakage detected is just over the preset threshold the full preset time delays are used If the leakage fault causes the full 600V to appear on the coach body the time delays are reduced to near zero A 300V fault will reduce the time delays in half and so on Test Switches Remote Inputs ISO Test and Body Test push button switches are provided on the 3800 2 module to simulate the occurrence of a leakage condition These allow the service technician to activate the timers and test the circuit operation A remote test input is provided that will allow a test to be activated from the dashboard of the vehicle This test input requires a 12 to 24VDC voltage source The remote test input activates both the ISO and Body circuits simultaneously A remote 12 to 24VDC input is also provided for the reset function at the dashboard A remotel2 to 24VDC input is also provided on the 3800 2 that disables the Ground Reference Integrity Monitor This input would be wired to a dashboard switch or a relay that operates when the vehicle is intentionally disconnected from the overhead lines Dashboard Controls The dashboard control switches connect to the 3800 2 module to provide the test reset and ground reference integrity disable functions The lights on the dashboard provide the display of isolated ground warning body ground warning and ground reference i
2. Ref 16 NC Body Leakage Oy fey ein O Integrity Relay Warning Relay A pe so oN 5 Com Gnd Ref 17 Com Body Leakage Integrity Relay Warning Relay l 6 NO Gnd Ref 18 NO Body Leakage E Integrity Relay Warning Relay ERES z 7 Remote Reset Input 19 Gnd Integrity Disable gt Input 8 Remote Test Input 20 Coach Body Ground 9 3800 1 Orange Wire 21 3800 1 Brown Wire 10 3800 1 White Wire 22 3800 1 White Wire for Dual Detection 11 12 24V Power In 23 Negative Power In 12 3800 1 Yellow Wire 24 3800 1 Blue Wire Fig 11 Fig 12 3800 2 Connector Pinout 3800 2 Mounting Footprint 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 12 Dashboard Wiring Diagram 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 13 rera rra rra ES ND es S i i i Lf Lf Lf n O eae eae tales od Io p 3800 1 High Voltage Module 1 l 0010 Me A d LA ES J eee J Fig 13 Operation 3800 2 Module As I mentioned on page 6 our clients have reported that the isolation characteristics are more important than the dual detection feature conseguently our wiring diagrams connect the isolated ground detection circuits to supervise the coach body When adhering to this configuration the yellow
3. body and earth ground A precautionary level of detection is also provided to monitor the voltage that may exist on the isolated ground of a double insulated vehicle The negative overhead rail of the trolley system is earth grounded at each sub station The 3800 detector uses this rail to establish a ground reference point The voltage on the coach body is measured relative to this point When there is a leakage resistance path that causes voltage on the body of the coach to rise above ground a dangerous condition could exist When the level of this leakage exceeds a preset threshold the detector initiates user adjustable timers The timers are used to prevent false alarms from line gaps or momentary power outages It the leakage is still detected upon timer expiry the 3800 will activate audible and visual devices mounted at the driver s console Leakage Path The polarity of the 600VDC in the high voltage area of the trolley coach upstream of the main contactor can change in some instances This could occur if the trolley runs in the opposite direction perhaps in a shunting yard where the left power connection pole connects to the right overhead line For whatever reason the 3800 detector must accommodate this To do so the 3800 1 module contains two high voltage diodes used to establish the ground A simplified sketch of the circuit is shown below Jody of Fig 2 Fig 3 If D1 s cathode connects to negative and D2 s cathode connects
4. if desired 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 7 Installer s Test Calibration Tests or adjustments should be made under controlled conditions and with a known overhead line voltage Dangerous voltages are deliberately placed on the coach body to verify the operation of the detector Skilled and gualified technicians only should do the tests and the coach should be cordoned off to prevent danger to observers Stray leakage resistances from the high voltage line to the coach body must not be present Also leakage resistances from vehicle chassis to earth through the tires must not be present We suggest that the vehicle be positioned such that it s tires rest on clean plexiglass plates to provide an insulation barrier between coach body and earth Failure to observe these reguirements could result in calibrating the detector in the presence of a fault and thereby de sensitizing the detector to a dangerous level To verify or adjust the detector with the isolated ground circuit being used to monitor coach body a 500K ohm 1W resistor should be placed between the 600V overhead line and the coach body The detector should inherently compensate for the catenary voltage and the detector should generate an alarm The voltage on the coach body can be monitored with a digital voltmeter and should fall in the range between 36 and 58V depending on the catenary volt
5. is at its expected maximum value of 720VDC To limit the danger the 3800 detector has an input resistance only to the negative overhead rail of 43K By doing this the detector limits the voltage on coach body with 500K leakage to 720Vx43K 543K 57V Any lower leakage resistance causes a higher voltage to appear on the coach body and would be detected by the 3800 even at its least sensitivity setting The 3800 2 module has only one isolated power supply for the detection circuitry intended to monitor the isolated ground The main detection circuitry must be powered externally If the coach battery supplies the power to the main detection circuits an optional internal 47K resistor would connect the coach battery to the body of the vehicle When the detector is wired in this manner it would still pass the flash test criteria stating that when 750VAC a 50HZ is applied for 1 minute the current flow must not exceed 15 milliamps If this resistive connection is not permitted you have 2 options You may either provide an isolated 12 or 24 volt source to power the detector consult factory or if willing to sacrifice the dual detection feature you may use the isolated ground detection circuit to monitor the coach body Since our clients have been more concerned with the isolation characteristics of the detector and have not needed the dual detection feature we have incorporated a compensation feature 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Te
6. to positive a leakage current from 600VDC can only flow through D1 D2 is reversed biased Fig 2 Conversely if D2 s cathode connects to negative and D1 s cathode connects to positive a leakage current from 600VDC can 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 5 only flow through D2 D1 is reversed biased Fig 3 For the sake of clarity all further discussions will assume the polarity of the overhead rails to be that of Fig 2 The detector monitors leakage both to the coach body and to the isolated ground The detection circuits are independent of each other but share the common ground reference point Fig 4 should clarify this Fig 4 Isolation Characteristics In order for any kind of detection circuit to ascertain if the coach body has a foreign voltage on it a ground reference point must be provided The vehicle runs on rubber tires which do not have an electrical connection to the ground Dragging a chain or ground strap will undoubtedly wear out and can never guarantee electrical contact The only reliable ground reference point available exists on the overhead lines If the coach body has no resistive connection to ground then any leakage at all between the overhead positive rail and coach body will result in the coach body immediately jumping up to that voltage This is obviously dangerous particularly when the catenary voltage
7. wiring harness A six pin terminal strip or a six wire in line weatherproof connector may be used The choice of connector is left up to the vehicle manufacturer Five 8 clearance holes are provided in the 3800 1 module The four corner holes are generally used for new installations however a fifth hole has been provided so that the mounting pattern matches the triangular footprint of the mounting holes used on ESC s previous product Model 4804 The wiring schematics and mounting footprints are shown in Figs 10 and 11 The dimensions shown are inches Fusing The high voltage wires provided are 18 gauge teflon jacketed wire rated to 2000 VAC and are 24 inches in length A suitable fuse is too large to embed in the epoxy module and should be provided by the vehicle manufacturer The fuse is required to prevent short circuits resulting from a failure of the high voltage diode within the 3800 1 module This would be a highly unlikely condition because the diodes used are overrated by at least a factor of 10 The circuit path within the high voltage module that must be protected is shown in Fig 7 DI 3800 1 Module HV Lead lt 600V gt RS HS a To 3800 2 Module HV Lead KOVD KI Da Fig 7 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 9 The polarity of the high voltage leads can be either direction ie D1 or D2 can be connected
8. A 4 rated polycarbonate box complete with a 24 pin dust and moisture resistant automotive style connector The 3800 1 high voltage module is cast in epoxy and is completely waterproof e Additional Isolation Level with Failsafe Operation The output circuits leading to the drivers display console are wired through dry contacts of relays that de energize in the event of a power failure to ensure failsafe operation A permanently operated remote reset switch does not prevent audible or visual alarm indicators e Ground Reference Integrity Monitor The connections to the overhead rails are monitored and will cause an alarm if disconnected This ensures that the detector has a ground reference point in order to measure leakage current A relay output is provided to light an indicator at the driver s 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 2 console and an input is provided to disable this monitor when the trolley is running on battery power e Isolated Ground Leakage Monitor To accommodate double insulation requirements of new vehicles an additional detection circuit to monitor the intermediate ground is provided Separate sensitivity and time delay adjustments are provided e Compensation Feature The trip level of the detector varies to compensate for voltage drops occurring on the overhead lines e Power On Indicator A power indicator as well a
9. Electronic Surveillance Corporation ESC 3800 LEAKAGE DETECTOR USER MANUAL a THU ll howe L eM ait 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Table of Contents INACIO 1 DESCRIPTION FFYN HF RR Y HY EN HF RR RH A HF FF RT FY FF HYR 2 ENHANCED FEATURES sscssccccssccscscciscissscssssesecdssccsecoscsscoscecsecosvocsesoesensescouooseccascvacsoasessescesecnasvesosesscesesoesovses sesdeccssecesv ess 2 SENIOR 3 BLOCK DIAGRAM wis svsscsssssssscsessescctecsecessecvesesseceascesesesoete pas e iasoer e obeas oraes kes Ces Ssu K sbstoeseseancebesvavessoseeuossessevesvasseuoosesseseese 4 THEORY OF OPERATION sssssssessssesscscscossessiecsecosssessssesececosvssedesencacoeeseseessssesscosssoasessssesessassessensssedbsccesessssodss n du dr d nov 56 sess 5 Ne e e FA RE FD FFF Re RO 5 INSULATION CHARATERISTIOS 4 vis is otit GYN K nd ik od ini duhur FI dur dhanore dan n d odave ri ero 6 SENSITIVITY ai tin dk O YO Y dhi d SF nat RR an ura le elsa 7 TNSTALLER S TEST CALTBRATION as 8 INSTALLATION INSTRUCTIONS vescuvosceusecovesssuanveceeeesseseuscseve se see vd End dor s es 9 3800 1 HIGH VOLTAGE MODULE aaa aaa aaa nan nese nen nene renie ee bene rere e tete peer eee eee eee tee teen tee tete pene tee tete teperta tete 9 BUSING nd 9 USE RATING nen TY CF CY NF y GY E 10 3800 2 DETECTOR MODULE cccccccncncnnncnononnnonononononononononononononononon
10. ISO Detect led indicates the existence of a leakage condition that has caused the voltage on the body of the vehicle to rise above a preset level set with the P7 adjustment Disabling the dual detector feature renders the yellow Body Detect led circuitry unnecessary These display leds have no built in timers or latching capabilities They act as status indicators to provide an immediate indication of the existence of leakage and are intended for use during maintenance service or calibration Rouge faults due to noise or static electricity may cause these leds to light momentarily and therefore cannot be relied on as the sole indication of leakage These leds are not displayed on the dashboard Should a genuine fault occur it must remain for a preset time before an indication will appear on the red warning leds P3 sets the delay time that must expire before an indication will appear in the ISO Warning led and P4 sets the Body Warning led delay The internal warning led circuits also drive relays whose contacts are wired to create similar indications on the dashboard of the vehicle When either warning led lights the latching delay timer starts The latching delay time is set by PS Should the fault disappear before the latching delay timer expires the warning led will extinguish and the timers will be reset If a warning led remains lit for the duration of the latching timer the Latching Alarm led will light Both lights will remain light until ma
11. N Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 1 ESC Model 3800 Leakage Detector 3800 1 Module 3800 2 Module Description The model 3800 leakage detector is a safety device that is intended to be installed in electric vehicles such as trolley busses that run on rubber tires and are powered from 600VDC overhead lines Its purpose is to generate a warning to the driver when the integrity of the double insulation reguirements of the vehicle has been compromised It can be used in new or upgrade installations The model 3800 provides additional safety and failsafe features and can be used as an electrical replacement for ESC models 4804 3614 and 3624 The detector consists of 3 main components the 3800 1 high voltage module the 3800 2 detector module and a remote control display panel that is provided by the vehicle manufacturer Enhanced Features e 2 Module Construction Splits the high voltage and low voltage circuitry This allows the 3800 2 module containing setup service adjustments to be installed in a low voltage compartment of the vehicle and the high voltage module may be located on the roof near the base of the overhead poles e Small Size The 3800 2 detector module measures only 3 7 x 7 1 x 2 3 The 3800 1 high voltage module measures 5 5 x 4 5 x 0 8 e Weatherproof Housing and Wiring Harness Connector The 3800 2 detector module is encased in a NEM
12. a Page 8 If you have wired the detector s power source to an isolated 12V to 24V source and are using the dual detection features the body ground detection level does not track catenary line voltage changes The trip level of this detection circuit is user adjustable between 20 and 65 volts as indicated by the blue and green lines and has been factory set to maximum P2 can be used to adjust this trip threshold Installation Instructions 3800 1 High Voltage Module A general practice is to keep all 600VDC wiring physically separated from the 12 or 24V wiring The reason for this is to decrease the danger to service technicians The 3800 1 high voltage module completely cast is epoxy and therefore its totally waterproof It is intended to be mounted in the high voltage area of the trolley bus This is generally on the roof of the trolley at a location near the base of the poles that extend up to the overhead power rails Since this product is generic and is provided to many trolley manufacturers ESC leaves it up to the individual manufacturer to provide a suitable location and provide mounting holes to accommodate the module The 3800 1 module needs to have connections to the overhead rails upstream of the main contactor This allows the leakage detector to operate even when the vehicle is parked and powered down Six low voltage wires connect the 3800 1 high voltage module to the 3800 2 detector module These wires should be included in the vehicles
13. age If the detector fails to detect an alarm a slight adjustment of P1 will reduce the threshold voltage of the detection circuit and should correct the problem If not or if a radical re adjustment is reguired then something is wrong and needs further investigation The detection threshold level can be set to detect leakage resistances from 500K ohms to as high as 6 megohms Fig 6 indicates how the detection threshold varies with changes in catenary line voltage If you calculate the voltage that would appear on the coach body as a result of a 500K ohm resistance you would find that it follows the isolated ground detection threshold as indicated by the red line This is the factory setting of the detector Should you wish to calibrate the detector to be more sensitive you should select the desired leakage resistance between 500K and 6 Meg ohms and connect this resistor between the 600V line and the coach body With this resistor connected adjust PI until the yellow LED lights Isolated Gnd V Detect Max 50 500K leakage resistance Isolated Gnd V Detect Min 6meg leakage resistance 30 Body V Detect Max Body V Detect Min Voltage Resulting from Leakage Resistance co al o o o o o o o o VO SS N O o o YN FT O o O A Y Y Y Y 0 O 0 0 O o 0 Catanery Voltage 640 660 680 700 720 Fig 6 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance c
14. ate of purchase due to DEFECTS IN MATERIAL OR WORKMANSHIP the unit must be returned to the dealer from whom it was purchased and the ELECTRONIC SURVEILLANCE CORPORATION will at its option either repair or replace the unit without additional charge to the customer This guarantee does not apply in the event of damage however sustained or tampering or servicing by unauthorized service agencies or misuse or abuse EXCLUSION of WARRANTIES The foregoing warranty is the sole warranty offered by the Electronic Surveillance Corporation hereby disclaims any implied warranty or fitness for any particular purpose In no event will the Electronic Surveillance Corporation be responsible for conseguential damages resulting from the use of this product 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 16 Specifications Electrical Operational Characteristic Specification Normal Operating Voltage Range low voltage power 10 to 35VDC a lt 200 ma using LED s amp Piezo Audible HV Operating Current from Overhead Lines lt 2 ma a 600 VDC Voltage Sensitivity Referenced to Earth Ground 18 amp 23 to 77 VDC default 40V User adjustable sec Page 7 Detection Levels Resistive 665Kohms to 6 5 Megohms User adjustable sec Page 7 Isolation Resistance HV lead to Coach Body gt 800 Megohms a 750VDC HV lead Positive Is
15. eillance ca Page 15 using a high voltage meg ohmeter megger The 3800 1 high voltage module can be left connected through out these tests however the 3800 2 module should be unplugged to protect internal circuitry Repair The smallest replaceable components consist of e The 3800 1 module This module is cast in a potting compound and cannot be repaired There is provision for a factory adjustment The module has proven to be very reliable and to date we ve had no failed modules Please return any suspect modules to ESC for analysis e The 3800 2 module The cabling harness to this module can easily be unplugged and the module is readily replaced There are no user replaceable parts Suspect modules must be returned to ESC for repair e Wiring harness connector Packard Electric Systems a division of Delphi Automotive Systems manufacture these connectors This connector is widely used by General Motors for their ignition modules There can be a long lead time to acquire small quantities of connectors e Connector assembly too part 12125080 Bench Testing Bench testing serves no purpose The user cannot repair either module The detector s functionality can be checked in the field Bench repair requires custom made test equipment and in depth knowledge of the design and operation of the product ESC is the only qualified repair depot Warranty In the event that your ESC product fails to function within 1 one year from the d
16. ference Integrity circuits will cause an alarm because they rely on full continuity through the diode establishing the ground reference Should D2 fail open the Ground Reference Integrity circuit would cause an alarm Should D1 fail open it would not be detected nor would it effect the operation of the 3800 This failure would be detected when the polarity of the overhead rails change Fuse Rating The maximum operating current that would flow through this fuse during the worst case leakage condition is 5 6 ma A fuse rating anywhere from 50 ma to 5 amps would be okay Should a fault occur within the 3800 1 module the maximum current that could flow would be limited by the resistance of 4 feet of 18 gauge wire This sets the interrupt rating of the fuse to gt 50000 amps therefore any fuse with a higher interrupt rating would be fine The fuse is in series with the 600 VDC overhead rails and when blown must block electrical transients that are reported to be as high as 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 10 1800V This sets its voltage rating ESC leaves the choice of fuse and fuse holder up to the vehicle manufacturer 3800 2 Detector Module The 3800 2 detector module is a low voltage device It may be mounted in any low voltage area of the vehicle The vehicle manufacturer must provide a suitable location and provide mounting holes to accommodate t
17. he module Four 10 clearance holes are provided in the corners of the box Access to these mounting holes is obtained by removal of the transparent lid Optional brackets are also available for more mounting flexibility Wire lead locks can be installed through cover screws A single 24 pin weatherproof header connector is provided on the module The mating connector can be supplied to connect to the vehicles wiring harness The connector contains the wires leading to the 3800 1 high voltage module and to the driver s console display on the dashboard All relay contacts have been terminated in the header connector to allow the vehicle manufacturer more flexibility in the way he may have to wire the audible or visual devices on the driver s display console The wiring diagrams mounting footprints and pinouts are shown in Figs 9 to 13 The dimensions shown are inches Driver s Console Dashboard Indicator and audible devices as well as test reset and ground reference disable switches are chosen by the vehicle manufacturer so that the appearance of the controls can be made to conform with other dashboard components The 3800 outputs are form C relay contacts providing normally open and normally closed contacts that could be wired in any manner the vehicle manufacturer chooses One client uses the latching alarm relay to trigger the vehicle s main contactor to open ESC suggests the use of light emitting diodes as indicators because of low current req
18. l 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 6 into the isolated ground detection circuit As a result our recommended wiring abandons the use of the dual detection feature Sensitivity The 3800 detector monitors the voltages that appear from isolated ground to the overhead negative coach body to the overhead negative and the catenary voltage as seen at the vehicle s location The level of sensitivity varies in accordance with the variation in the catenary voltage This is referred to as the compensation feature of the detector and is incorporated into the isolated ground detection circuitry only As the catenary voltage decreases due to loading effects of other trolleys the trip level of the detector decreases to offset the positive shift in the ve overhead rail being used as the earth ground reference See Figure 5 below Fig 5 The calibration of the detector has been set to create an alarm at both extremes of the overhead line voltage when a 500K ohm leakage condition exists The voltage on the coach body resulting from this 500K leakage resistance would range from 57V when catenary is at 720V to 33V with catenary a 420V The alarm detection threshold level tracks the catenary voltage User adjustments have been provided to control the threshold voltage and have been factory set at maximum This sets the detector s minimum sensitivity and can be increased by the user
19. ntegrity The audible alarm function is provided at the dashboard by a piezo electric buzzer These controls wire to the remote inputs and outputs of the 3800 2 module and function in the same manner as described above Note there is only one test switch that activates both the ISO Warning and the Body Warning function Servicing Operational Testing The driver through the use of the test and reset switches provided on the dashboard can check the basic operational functionality of the detector To confirm operation of the ground reference integrity monitor you can lower the overhead poles and verify that an alarm sounds Refer to page 12 for a description of the dashboard controls and their expected operation Some vehicles are equipped with an interlock feature that stops the traction motor in the event of an alarm The driver may press the test switch to cause a test alarm and then verify that the interlock works Calibration and sensitivity testing requires a qualified service technician and the procedure has been covered on page 6 Isolation Testing The transit authority stipulates that the vehicle must periodically pass a series of insulation breakdown tests ESC cannot define these procedures because they involve testing of the traction motor inverter and all other electrical equipment on the vehicle The tests are normally performed 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurv
20. nually reset The Latching Alarm led also drives a relay to operate the audible device on the dashboard of the vehicle The Ground Reference Integrity Monitor monitors the voltage on the overhead lines to ensure that the negative power connection alias the leakage ground reference point exists This circuit has a built in 45 second timer that starts when the voltage disappears and resets when the voltage is present When the time delay expires the red GND Integrity led lights the ground reference integrity monitor relay operates and the Latching Alarm circuit will be triggered to cause an audible alarm at the dashboard Pressing the manual Resef button acknowledges receipt of alarm will cause the Latching Alarm led to extinguish and allows the warning led to reset when the fault condition no longer exists While any warning led remains lit additional faults will not cause the alarm audible The sensitivity adjustments P7 and P2 are user adjustable and have been factory calibrated as discussed on page 7 The time delay adjustments P3 and P4 are factory calibrated to 5 seconds PS is set to 3 seconds and each offers a user adjustable range from approximately 0 5 to 20 seconds The adjustments once set are locked in place by the lock nut provided on the calibration potentiometers 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 14 Adaptive Threshold Trip Level
21. olation Resistance HV lead to Isolated Ground gt 800 Megohms a 750VDC HV lead Positive HV Lead Maximum Operating Voltage 2 0 KVAC 70 C Transient Performance Immunity gt 15KV for 8 3ms 25 C Voltage Flash Test HV Lead to Vehicle Body lt 12ma 3500VAC 60Hz for 1 Minute Output Relay Contact Rating 10A a 250 VAC 10A a 30VDC Relay Contact Life Expectancy electrical operations 105 at 20 cpm Resistive Load Warning amp Alarm Time Delay Range Approx to 20 seconds default 3 amp 5 user adjustable Ground Reference Integrity Delay Approx 45 seconds Factory Set Remote Inputs 10 to 35VDC 15ma maximum Mechanical Environmental Characteristic Specification Shock Resistance Functional Min 98 m s 10 G Vibration Resistance Functional Approx 98 m s 10 G 10 to 55Hz double amplitude of 1 6mm Pp Size 3800 1 4 5 x 5 5 x 0 75 inches 3800 2 7 75 x 3 75 x 2 25 inches Weight 3800 1 440 grams approx 3800 2 510 grams approx Temperature Range 3800 1 30 C to 60 C Operating 40 C to 90 C Storage Temperature Range 3800 2 0 C to 60 C Operating 40 C to 70 C Storage Humidity 75415 750430 mm Hg 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 Page 17 info electronicsurveillance ca
22. ono nono nonnnonn nono nono nono nono nono nono nono nono nono nono nono nora nora nonnnnnnnnnnns 11 DRIVER S CONSOLE DASHBOARD occccccccccnnononnnononnnnonnononenenocnnnnnnn nn re ses vese nn nn ee ses vese eeeeee teve eee eee nn narra LLAD DD WN 11 WIRING DIAGRAMS ies iccsdsdecisisiccsccnsevececisticdisssecsicavedscacessesedeshsvesicsedecesccsnvesscsssavs e od san r 12 OPERATION NO 14 3800 2 AAA 14 ADAPTIVE THRESHOLD TRIP LEVEL aa aa aa va ca ca ca ea ea enes enes enes enes ee es es enen enes ALI A es es enes III enes enes es enes es IL DH 15 TEST SWITCHES REMOTE INPUTS sa au au aaa na aa aa an au nu nane se ee enen pere ee sete nese eeee recete veme LLAC teze ve vese meme te see eee eee eteseveveserereeee LD WN 15 DASHBOARD CONTROL AAA 15 SER AAA sosveesesoeuocsssoesessesceueecesoossesesssueedesseses 15 OPERATIONAL TESTING isis k sos dum s dhe sxcesavexsuscutseaeseue sxeuscunsveuseuesuswscuusyGessevsxsuscunsvewssunesewscusexcuseuesseuseenssenecensvenscubexceseencses 15 ISOLATION TESTIN G cis iss sete cats ha is 15 REPAIRS uu dd h dh ate 16 BENCH TESTING 1 Y GU ise oes idaw vax dd ea a oe th eevee 16 WARRANTY SA 16 SPECIFICATIONS NN HEFFER EE RR NE RA RHED 17 ELECTRICAL OPERATIONAL coincida adi daj s es iia WN dd d 17 MECHANICAL ENVIRONMENTAL cccccccssssccecsssceceessccecesssecccsececeesseeecesssececsseecsessececesssececseeecsesseeccnsssseeensseeceesaseecsnaaecs 17 Documentation Rev 4 1 90 Nolan Court Unit 34 Markham O
23. s all alarm and fault lights are including in the 3800 2 detector module and may be viewed through a tinted black transparent lid Standard Features e Extended Operating Voltage The 3800 leakage detector operates in vehicles with either 12 or 24 volt battery systems e Remote Display Outputs and Remote Test and Reset Inputs The vehicle manufacturer wires his dashboard controls and indicators to these points e Status Indicators Test and Reset Buttons The 3800 2 detector module includes 7 indicator lights and 3 test buttons The indicators show instantly if a leakage a warning or an audible alarm condition exists The test and reset buttons allow a field service technician to test and calibrate the delay times of the detector e Alarm Response Delay Adjustments Individual delay adjustments are provided for both alarm warning circuits and for the audible device located at the driver s console e Sensitivity Adjustments In field calibration adjustments are provided to set the sensitivity of the leakage detection circuits for both the coach body detector and the isolated ground detector e Delay Reduction Circuitry Preset alarm response time delays are reduced based on the severity of leakage that exists on the coach body 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 3 e Block Diagram A simple block diagram of the 3800 Leakage Detector i
24. s shown in Fig 1 600V Overhead Lines Dashboard Ground Reference gt Overhead Voltage Isolated Ground gt Isolated Ground Teale tore Steering Circuit Monitor Foult Level Warning Delay and Don trol r gt Detector Timer Display Indicator Sensitivity Display Indicator Adjustment and Timer and Service Adjustment Test Switch Display Indicator Sensitivity Display Indicator gt Dashboard Dashboard 3800 1 Module Adjustment and Timer Indicator Controls J and Service Adjustment Relays i a y Test Switch Ls Coach Body Ground Coach Body Ground Latching Alarm Reset Button Foult Level Warnin 9 Delay Delay Timer ond Reno Detector Timer Reset Circuitry Timer Duration Display Indicator Reduction Circuitry ond Tiner Adjustment Power Supply Regulators F Logic Circuits 3800 2 Module Fig 1 The 3800 1 is an epoxy module that is located on the vehicle s roof near the base of the poles that connect to the overhead rails The insulation qualities of the module meet and exceed the requirements of IEC 77 for 1 level insulation voltage withstand i e a flash test voltage of 3 5KV 50Hz for 1 minute The 3800 2 module is housed in a polycarbonate box that may be located in any low voltage area of the vehicle This mod
25. to either the 600V overhead line or the negative overhead line For the purpose of discussion this manual assumes that D1 connects to 600V If D2 fails short there would be no indication on the 3800 detector because the negative rail is inherently used as the reference point of the leakage detector The only danger that may exist on the coach body would be from possible transients or voltage drops that occur along the length of the overhead wires on the street resulting from other vehicles sharing the lines This danger is limited because the coach body is isolated from the overhead rails by R5 This resistor limits any possible current that could flow to a safe value Under this condition the sensitivity of the detector would increase because the forward voltage drop across D2 would drop from 10V to zero Should D1 fail short D2 would be forward biased and a potential fire hazard exists A single fuse inserted in series with either DI or D2 would protect against this condition Fig 8 The fuse is shown here on the negative side Fig 8 Assuming D1 connects to 600V and has failed short D2 becomes forward biased and the fuse F1 would blow At this time the coach body would be raised through R5 to 600V Again RS limits the available current flow to a safe level Since the detector has lost it s ground reference point the leakage detection path cannot be completed and the detector will not detect the leakage condition however the Ground Re
26. uirements and nothing to burn out The current limiting resistor can be mounted externally or can be included within the device as in the IDI model 1091M1 24V The audible device could be a Mallory Sonalert model SC628 however the choice is open The selection criterion is based on operating voltage sound frequency amp pressure and mounting amp wiring requirements The test and reset switches must be momentary and must have normally open contacts The ground reference integrity monitor disable input could be a toggle switch or could be relay contacts from other equipment that provide a closed circuit when the overhead power poles are lowered A possible wiring configuration is shown in Fig 13 Alternate wiring configurations can be discussed upon request 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 11 Wiring Diagrams Fig 9 a OTOR ooa 2 3800 1 Wiring Diagram Fig 10 3800 1 Mounting Footprint Pin Connection Pin Connection 1 NC Isolated Gnd 13 NC Latching Alarm Warning Relay Relay Audible 2 Com Isolated Gnd 14 Com Latching Alarm Warning Relay Relay Audible 3 NO Isolated Gnd 15 NO Latching Alarm Warning Relay Relay Audible i 1 4 NC Gnd
27. ule forms the heart of the detector It consists of integrated circuits transistors relays etc and is powered by the vehicle s low voltage supply 12 to 24VDC The module provides the control circuitry to activate timers and drive relays that cause an indication on the dashboard in the event of a fault condition The dashboard controls consist of warning and alarm indicators usually light emitting diodes a latching audible device sonalert or pieso electric device and test and reset switches 90 Nolan Court Unit 34 Markham ON Canada L3R 4L9 Tel 905 479 7116 Fax 905 477 2826 info electronicsurveillance ca Page 4 Theory of Operation In electric vehicle systems i e trolley coaches oil dirt and moisture can accumulate on insulators that separate the overhead power lines from the coach body This accumulation is electrically represented as a resistance This resistance can cause an unwanted leakage current to flow from the 600VDC overhead power line to the coach body thereby creating a potential shock hazard to passengers boarding the vehicle In double insulated vehicles two levels of insulation exist Both levels of insulation would have to be compromised before any human shock hazard could exist The purpose of the 3800 leakage detector is to alert the bus driver if the body of the coach has become electrically charged to a dangerous level To do this the leakage detector monitors the voltage that may exist between the coach