Home
Bullard T4MAX Thermal Imager User Manual www.bullard.com
Contents
1. o a Sullar d Bullard T4MAX Thermal Imager User Manual Congratulations Congratulations on the purchase of your new advanced Bullard T4MAX Thermal Imager The Bullard T4MAX combines advanced thermal imaging technology with our expertise in high heat impact resistant engineered polymers to bring you the most durable thermal imager on the market The T4MAX s innovative compact design and logical easy to use interface presents a truly personalized thermal imaging tool to today s firefighters The benefits of using thermal imaging technology as a firefighting tool encompass nearly every aspect of a firefighter s job Thermal imaging is not however a technology designed to replace current firefighting tactics Rather it is a tool that allows the firefighter to be more effective and make better decisions Some of the many uses for your Bullard T4MAX Thermal Imager include Search and rescue Scene assessment Locating the seat of the fire Determining the spread of the fire Locating hot spots Identifying potential flashover situations Determining ventilation points Determining entry and exit points Overhaul e Hazmat e Wildland firefighting e Incident investigation Training NOTE To ensure that we are able to reach you with any product or software updates please fill out the warranty card enclosed with your Bullard T4MAX Thermal Imager A WARNING Read all instructions and w
2. seconds to calibarate from initial startup During this short startup period the Electronic Thermal Throttle or Digital Zoom will not engage Digital Zoom Feature The T4MAX enables magnification of far away scenes at both 2x and 4x zoom With one simple push of the black Z button located next to the power button under the LCD display the 2x zoom is enabled Figure 2 A second push of the button activates the 4x zoom A third pushofthe 4 button disables the zoom function The Digital Zoom feature also works seamlessly with Electronic Thermal Throttle and Super Red Hot Using the Battery Charger The battery should be charged in the battery charger using either the AC or DC adapter provided Figure 3 To charge a battery insert it into the charger so that the metal contacts on the battery are aligned with the metal contacts in the charger A red light will illuminate on the charger to indicate that the battery is charging When the light on the charger turns to green the battery is fully charged You may leave the battery in the charger indefinitely as the battery will not overcharge and the charger will initiate a trickle charge to maintain the battery s charge For maximum battery life and performance you should remove the battery from the charger and discharge it completely on a monthly basis 1 NOTE Tf you do not see the red LED illuminate when you place a battery into the charger the battery is not charging
3. HI The RHI will indicate the approximate temperature of the object viewed within the crosshairs shown in the middle of the screen The accuracy of the indicators is dependent on numerous factors including the distance from the object being viewed and its emissivity which is the object s ability to radiate heat Units are calibrated with a preset emissivity corresponding with normal construction materials Objects with emissivities that vary greatly from this such as metals and shiny objects will reduce the accuracy of the temperature indication Additionally temperature measurement accuracy decreases as the distance from the object in the crosshairs increases NOTE The RHI provides a quick reference to compare objects of similar emissivities to serve as a guide to pinpoint intense heat sources Due to the inherent issues with accuracy use this feature with caution and verify indicated heat levels through traditional means whenever possible Super Red Hot Feature The T4MAX features Super Red Hot high heat colorization With the Super Red Hot feature heat levels are identified by various color hues Starting at 500 degrees heated objects are tinted yellow and gradually transition to orange and then solid red as heat levels rise The Super Red Hot feature identifies specific heat layers alerting firefighters to areas of intense heat This feature provides an enhanced visual awareness of the hottest objects in a scene Electronic
4. Loading Unloading the Battery Loading and unloading the battery on the Bullard T4MAX is straightforward Figure 4 To install a battery slide the battery into the groove on the bottom of the unit and ensure that the battery is properly seated To remove a battery depress both battery locking buttons simultaneously and slide the battery out of the unit Since it can only be loaded one way the battery is easily replaced in the dark Additionally as with all batteries your Bullard rechargeable battery will experience a slow drain of its charge during storage The amount of drain varies widely based on storage conditions For best performance charge each of your batteries every two weeks Power Button Zoom Button Figure 2 Figure 3 Battery Locking Buttons AWARNING Do not allow the metal contacts on the label side of the battery to come in contact with a conductive surface such as a metal table or another battery This can complete the battery circuit and cause the battery to overheat or melt Failure to observe this warning may result in permanent battery damage property damage and or serious injury NOTE Fully charged NiMH batteries will provide a run time of more than three hours This run time will be less in extreme heat or extreme cold conditions and or if the transmitter is in use To extend the potential lifespan of your batteries fully drain and recharge each battery monthly To help extend the life
5. Thermal Throttle The T4MAX incorporates a highly useful and unique feature the Electronic Thermal Throttle The Thermal Throttle is ideal for pinpointing hot spots during overhaul searching for overheated electrical equipment or clarifying objects in ambient temperature situations To activate the Thermal Throttle option locate the two black buttons on the top of the T4MAX Figure 1 Press the down button the button closer to the front of the imager to activate the Thermal Throttle The Electronic Thermal Throttle will automatically sense the hottest area in the scene and color it blue Continuing to press the down button or holding it down will further engage the Thermal Throttle and will color more of the scene blue eventually coloring even the coolest objects blue NOTE As the throttle engages more of the scene the blue will become lighter in hue to help differentiate objects in the scene As you cycle through the scene you ll see the symbol TT and a corresponding number in the bottom left corner of the display The TT indicates Thermal Throttle mode The number 0 100 is a point of reference to indicate the level of Thermal Throttle engagement by itself it has no specific meaning To lessen the amount of blue in the scene press or hold the up button Alternatively pressing both buttons simultaneously for one second will deactivate the Thermal Throttle NOTE The T4MAX Thermal Imager takes approximately eight
6. arnings before using this product Your thermal imager is like any other tool It must be used properly and safely All users should be trained on the proper and safe use of thermal imaging prior to using the T4MAX Thermal Imager This is especially important for users who may use the T4MAX Thermal Imager in hazardous or IDLH immediately dangerous to life and health environments Failure to follow this information could result in death or serious injury Bullard T4MAX Thermal Throttle Rear Boot LCD Screen Lens Bezel Zoom Button Lens E Power Button Side Strap Battery Figure 1 www bullard com aSullard Use and Operation Power To turn on your Bullard T4MAX Thermal Imager depress and release the large red power button under the LCD display Figure 2 Upon pressing the power button the thermal imager will display the Bullard logo and initiate a calibration sequence The thermal image will appear within four seconds To turn off power depress and hold the power button for three seconds and release NOTE You will periodically observe a momentary freeze in the image This is normal and is a function of the self calibration shutter The shutter will activate every 30 seconds to three minutes depending on the environment Relative Heat Indicator RHI The T4MAX is equipped with temperature measurement capability The right side of the display will show a bar graph or Relative Heat Indicator R
7. cover display Store your thermal imager in the optional truck mount or in the delivery case provided All thermal imagers should be maintained using a proper program Cleaning the Lens The Bullard T4MAX lens is recessed in an impact resistant bezel The lens can be cleaned with a soft cloth and soapy water as required Replacing the Video Display Cover Window The display cover Figure 7 has a scratch resistant hard coating to minimize marring However if heavy scratching or gouging does occur the cover window can be replaced To do this simply remove the six screws along the top bottom and sides of the window Remove the plastic display cover window and replace with a new one part number T4WINDOW making sure that the countersink slots around the mounting holes are facing outward Do not over tighten Sa Figure 7 CAUTION Do not use solvents or paint thinners to clean your Bullard T4MAX Thermal Imager as they could permanently mar the surface or degrade the protective properties of the casing Do not intentionally submerge the unit underwater or subject the unit to high pressure water Follow care instructions described above Failure to observe these instructions may result in product damage Any damage caused by improper care is not covered under warranty AWARNING Do not attempt to disassemble the Bullard T4MAX Thermal Imager If the unit is not functioning promptly return it to Bullard for evaluati
8. eturn authorization number Tf the return is a non warranty repair a Bullard Customer Service Representative or your local distributor will provide you with a repair invoice estimate To authorize repair you must provide a purchase order to your distributor for the amount of the estimate Once Bullard receives authorization from your local distributor we will issue you a return authorization number so that you can return the unit to Bullard Bullard will repair the unit and ship it from our factory within 48 business hours If the cost of repairs exceeds the stated quote by more than 15 or by more than 100 a Bullard representative will re estimate your repair and your local distributor will contact you for authorization to complete repairs After repairs are completed and the goods have been returned to you your distributor will invoice you for the actual repair amount NOTE Do not attempt to disassemble the sealed case of your Bullard Thermal Imager If the unit is not functioning properly return it to Bullard as described in the Service section for evaluation Disassembling the unit voids all warranties Prior to returning your Thermal Imager decontaminate and clean your Thermal Imager to remove any hazardous or contaminated materials that may have settled on the product during use Laws and or shipping regulations prohibit the shipment of hazardous or contaminated materials Products suspected of contamination will be profess
9. ionally decontaminated at the customer s expense Returned products will be inspected upon return to the Bullard facility If the repair is under warranty Bullard will repair the unit and ship it from our factory within 48 business hours aSullard Warranty Bullard warrants to the original purchaser that the Bullard T4MAX and all features accessories installed in the unit are free of defects in materials and workmanship under intended use and service for a period of one 1 year from date of manufacture Bullard s obligation under this warranty is limited to repairing or replacing at Bullard s option articles that are returned within the warranty period and that after examination are shown to Bullard s satisfaction to be defective subject to the following limitations a Article must be returned to Bullard with shipping charges prepaid b Article must not be altered from its original configuration c Article must not have been misused abused or damaged in transport d Maintenance and field replaceable items if defective are covered under warranty for a ninety 90 day period These items include Batteries Straps Display covers AC DC adapters All accessories except transmitter and Mobile Link or Mobile Command Center remote receivers Bullard provides a limited lifetime warranty on the TAMAX outer shell This warrants that the outer shell is free of defects in materials and workmanship under intended u
10. of the rechargeable batteries and prevent unexpected instances of uncharged batteries develop a clear formalized plan for maintaining charging and replacing your batteries Bullard provides an optional AA Alkaline battery case which can be used as an alternative to the standard 10 V NiMH rechargeable batteries The AA alkaline battery case requires eight AA alkaline batteries Once the batteries are installed the case loads into the unit in the same manner as the standard NiMH battery Due to the unique way that alkaline batteries disperse power to the unit the LED indicators will report battery levels that are not necessarily indicative of the battery s actual remaining charge Fully charged AA Alkaline batteries will typically operate a Bullard TAMAX Thermal Imager for two hours Do not insert the AA Alkaline battery case into any Bullard battery chargers including the Powerhouse Bullard T4MAX Thermal Imager User Manual A WARNING The T4MAX thermal imager is extremely sensitive to intense radiant heat sources Never point the T4MAX at the sun or any other source of extreme radiant heat as this could severely damage the thermal imager Strap Assemblies Side Straps The side straps are designed to be field replaceable Users can order replacements and install them without having to return the thermal imager to the factory Removing Installing the Side Straps To remove either of the right or left side straps loosen the s
11. on Disassembling the unit voids all warranties Like all thermal imagers sold at the time of this printing the Bullard T4MAX is not certified as intrinsically safe Do not attempt to remove the lens gasket or the rear boot These parts provide sealing and removal will break the seal exposing the unit to potential water damage Failure to follow these instructions could result in death serious injury and or product damage Thermal Imaging is not a technology designed to replace current fire fighting tactics Rather it is a tool that allows the firefighter to be more effective and to make better decisions Firefighters cannot stop using basic firefighter safety tactics All firefighters should receive proper training on how thermal imagers work the uses and limitations of thermal imagers image interpretation and the safety considerations for thermal imaging use Service Tf your Bullard Thermal Imager is not performing properly please contact Bullard Customer Service at 877 BULLARD 285 5273 Outside the US amp Canada call 1 859 234 6611 Describe the problem to the Bullard representative as completely as possible For your convenience your representative will try to help you diagnose or correct the problem over the phone Before returning your Bullard Thermal Imager you should verify with your representative that the product should be returned to Bullard Bullard Customer Service will provide you with written permission and a r
12. plus one additional year This warranty can be purchased through any authorized Bullard distributor For accessories upgrades and replacement parts visit www bullard com call 877 BULLARD or contact your local Bullard distributor Americas E D Bullard Company 1898 Safety Way Cynthiana KY 41031 9303 Toll free 877 BULLARD 285 5273 Tel 859 234 6616 Fax 859 234 8987 www bullard com Europe Bullard GmbH Lilienthalstrasse 12 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 www bullardextrem com Asia Pacific Bullard Asia Pacific Pte Ltd LHK Building 701 Sims Drive 04 03 Singapore 387383 Tel 65 6745 0556 Fax 65 6745 5176 www bullard com ISO 9001 certified 2009 Bullard All rights reserved Super Red Hot Relative Heat Indicator and T4MAX are trademarks of Bullard 60500591494 1109
13. se and service for the original purchaser Bullard s obligation under this warranty is limited to repairing or replacing at Bullard s option articles that after examination are shown to Bullard s satisfaction to be defective subject to the following limitations L Article must not be altered from its original configuration 2 Article must not have been misused abused or damaged in transport 3 When the outer shell is obsolete and Bullard no longer stocks the part the limited lifetime warranty will be terminated In no event shall Bullard be responsible for damages loss of use or other indirect incidental consequential or special costs expenses or damages incurred by the purchaser notwithstanding that Bullard has been advised of the possibility of such damages Any implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to one 1 year from the date of manufacture of this Some states do not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state Extended Warranty The extended warranty has all the same terms and conditions as the one year warranty except it is for a period totaling two years standard one year warranty
14. trap and pull it through the strap loop located on either side of the LCD display Figure 5 Remove the screw that holds the strap to the imager To install fasten the strap to the unit using the screw provided Do not over tighten Feed the strap through the strap loop and adjust to the desired length Adjusting the Side Straps To adjust a side strap loosen the hook and loop and set to the desired length Combination Strap The combination strap Figure 6 can be used either as a wrist strap to keep the imager from falling if it should slip from your hand or as a gear strap hooked directly onto your turnout gear or SCBA As a wrist strap the adjustable strap fits over the sleeve of your turnout gear and can adjust to any size wrist The strap can be easily attached to either D ring located on the thermal imager As a gear strap the strap can be attached to a D ring on your turnout gear or SCBA and to a D ring on the thermal imager A quick release buckle serves as a Safety release mechanism in case the thermal imager ever becomes lodged inhibiting movement Simply depress the buckle and the thermal imager releases from the strap Figure 6 Care Instructions The Bullard T4MAX Thermal Imager requires little maintenance For best results after each use Clean the outside of the unit with mild soap or detergent Wipe the lens with a soft cloth Clean the display with a soft cloth e Check screw tightness on side straps and
Download Pdf Manuals
Related Search
Related Contents
EVGA GeForce GTX 285 GeForce GTX 285 1GB ProSystem fx® Electronic Filing How to Set Up - Support LG New Wide Wired Remote Controller ALMA 24/28 MB W TOP - Certificazione Energetica ガンコなシミや腐食の原因になります。 modelo: serie 1203 manual del propietario Installationsanleitung Ryobi P780 Use and Care Manual 9000XLoad User Manual Copyright © All rights reserved.