Home

in.k600 for in.xe with streamlined interfaces QRC

image

Contents

1. Quick Reference Card Please consult your spa user manual for complete info on the features of your spa system in k600 with in xe Compact full function keypads for in xe spa systems Aeware s advanced in k600 keypad features a low profile with a large LCD display streamlined interface and raised keys that let users easily control all in xe functions and programming directly from spa side creating a true and unique user experience ninata fi Plus Key Blower icon Ok Key Program Key Pump icons Light Key Function Description Time temperature amp message digits Program icon Heating icon Filtering icon Smart winter mode icon AM PM F C Set point icon Service icon Pump Keys Left Key Minus Key Standby Key Right Key Spa Functions On Off key Depending on the spa manufacturer this key may have one or acombination of the following functions Standby and or On Off and or Economy mode e The first mode activates deactivates via a short press on the key The second mode if present activates via along press of 3 to 6 seconds and deactivates via a short press on the key The third mode if present activates via along press of 6 to 9 seconds and deactivates via a short press on the key Pump2key 2 Press Pump 2 key to turn Pump 2 on at low speed Press a second time to turn pump to high speed with a
2. dual speed pump A third time turns pump off An integrated timer automatically turns pump off unless pump has been manually deactivated first The Pump 2 indicator lights up when Pump 2 is on With dual speed pump indicator will flash when pump 2 is on at low speed Standby Mode This mode allows you to stop all outputs and automatic functions with the exception of the heat request for 30 minutes When active the display will toggle between the Sby message the clock and the water temperature In order to restart the system before the expira tion of the 30 minutes delay make a short press on the On Off key The spa light will flash a few seconds before the end of the 30 minutes to warn you the system is about to resume its normal operation When the system resumes its normal operation the display shows On for 3 seconds On Off Mode This mode allows you to stop all outputs including all automatic functions such as filter cycle heat request and smart winter mode purge for 30 minutes to perform quick spa main tenance When active the display will toggle Blowerkey 3 Press Blower key to turn Blower on Press a second time to turn Blower off An integrated timer automatically turns blower off unless blower has been manually deactivated first The Blower indicator lights up when blower is on between the OFF message the clock and the water temperature In order to restart the syst
3. stop all outputs including all automatic functions such as filter cycle heat request and smart winter mode purge for 30 minutes to perform quick spa maintenance When the Off mode is active the display will toggle between the OFF message the clock and the water temperature Press either Pump 1 Pump 2 Blower or On Off key to restart the system before the expira tion of the 30 minutes delay The spa light will flash a few seconds before the end of the 30 Lightkey 364 Press Light key to turn light on A second press turns light off A built in timer automatically turns light off after 2 hours unless it has been manually deactivated first The Light indicator lights up when light is on minutes to warn you the system is about to resume its normal operation When the system resumes its normal operation the display shows On for 3 seconds The Pump 1 indicator lights up when Pump 1 is on With dual speed pump indicator will flash when pump 1 is on at low speed If single speed pump press Pump key to turn pump on Press Pump key again to turn pump off e m Keys Use or key to set desired water temperature The temperature setting will be displayed for 5 seconds to confirm your new selection The Set Point icon indicates that the display shows the desired temperature NOT the current water temperature Programming steps Programmenu Depending on the keypad configurati
4. cy Use the Program or OK key to jump to the next pa rameter economy mode EP The Filter cycle indicator lights up when filter is on Flash when suspended Setting Economy duration Setting economy duration The display will show Edxx xx re presenting the duration in hour of the economy mode Use the Up or Down key to adjust the hour Use the Program or OK key to jump to the next parameter temperature unit 0 no economy 24 continuous economy in xe error codes Troubleshooting section Setting the purge cycle start time The display will show PSxx xx representing the starting hour of the purge cycle Use the Up or Down key to adjust the hours Use the Program or OK key jump to the next para meter purge frequency PF Setting temperature unit Water temperature can be displayed in either Fahrenheit F or Celsius C The display will show F or C Use the Up or Down key to change the setting Use the Program or OK key to save all the parameters Description Setting purge cycle frequency The display will show PFxx xx representing the number of purge cycles per day Use the Up or Down key to adjust the frequency Use the Program or OK key to jump to the next parameter economy mode EP The Purge cycle indicator lights up when purge is on Flash when suspended Smart Winter Mode Our Smart Winter Mode protects your system from the cold by turning pu
5. d 108 F 42 C Do not enter the water Remove the spa cover and allow the water to cool down to a lower temperature If problem persists Note the error message and contact dealer or service supplier for Tech Support The system has shut the heater down because the temperature at the heater has reached 119 F 48 C Do not enter the water Remove the spa cover and allow the water to cool down then shut power off and power your spa up again to reset the system If problem persists note the error message and contact dealer or service supplier for Tech Support The system does not detect any water flow while the primary pump is running Check and open water valves Check for water level Clean filter If the problem persists call your dealer or service supplier A problem is detected with the temperature probe Note the error message and contact dealer or service supplier for Tech Support 9919 100820 C www geckoalliance com
6. e the Up or Down key to adjust the duration Use the Program or OK key to jump to the next parameter filter frequency FF 0 no filtration 24 continuous filtration It s not recommended to set this to 0 Setting Economy start time The display will show ESxx xx representing the hour at which the economy mode will become active Use the Up or Down key to adjust the hour Use the Program or OK key to jump to the next param eter economy duration Ed When the Economy mode is ON the display will toggle between the Eco message and the water temperature Cooldown After heating the spa water to the desired Set Point the hea ter is turned off but its associ ated pump Pump I Low speed or CP remains on for a prede termined period of time to ensure adequate cooling of the heating element this prolongs its useful life The heater icon flashes during this time if required the system automatically turns the heater on to reach and maintain water temperature at Set Point The heater indicator lights up when the heater is on Indicator flashes when taking water temperature reading Temperature inside the spa skirt is too high causing the internal temperature inthe Spa Pack to increase above normal limits Open skirt and wait until error clears If error persist note the error message and contact dealer or service supplier for Tech Support The water temperature in the spa has reache
7. em before the expiration of the 30 minutes delay make a short press on the On Off key The spa light will flash a few seconds before the end of the 30 minutes to warn you the system is about to resume its normal operation When the system resumes its normal operation the display shows On for 3 seconds Manual Economy Mode This mode allows you to save some energy by regulating the water temperature 20 F 11 C below the actual set point When active the display will toggle between the Eco message the clock and the water temperature Make a short press on the On Off key to exit the manual economy mode When the system exits the economy mode the display shows noE for 3 seconds Integrated timer OK This button allows you to change the duration of the integrated timer that automatically shuts off the pumps and blower Press OK and dxx will appear on the screen with xx representing the duration of he timer in minutes Use the buttons to adjust the time between 10 and 60 minutes by increments of 5 minutes Press OK again or wait 5 seconds to save the new duration Pump 1 Offkey 1 Press Pump 1 key to turn Pump 1 on at low speed Press a second time to tum pump to high speed with a dual speed pump A third time turns pump off An integrated timer automatically turns pump unless pump has been manually deactivated first A long press of 5 seconds will enable the Off mode This mode allows you to
8. mps on several times a day to prevent water from freezing in pipes The SWM indicator lights up when a freeze condition is detected and flashes when the purge is active An internal hardware error has been detected Note the error message and contact dealer or service supplier for Tech Support Setting filter cycle start time The display will show FSxx xx representing the starting hour of the filter Use the Up or Down key to adjust the hours Use the Program or OK key to jump to the next parameter filter duration Fd Setting Economy mode This mode allows you to lower the temperature set point of the spa by 20 F 11 C during a certain period of the day The display will show EPx x representing the state of the programmed economy 0 disable 1 enable Use the Up or Down key to set the program economy to enable or disable Use the Program or OK key to jump to the next parameter economy start time ES Water temperature regulation In a regulation cycle the sys tem first generates water flow through the heater housing and the plumbing in order to ensure accurate water tempe rature readings as well as avoiding heater activation in dry conditions After verifying pump activation and taking a water temperature reading Setting filter cycle duration The display will show Fdxx xx representing the duration in hour of the filter cycle Us
9. on the program menu will be accessible via the Program key check mark A long press of 5 seconds will allow you to enter the program menu In the program menu the following parameters can be set the clock the filter cycles or the purge cycles the economy mode and the temperature units While you are in the program menu use the Up or Down keys to adjust the parameters and use the Program or OK key to jump to the next parameter The changes will be saved after the confirmation of the last parameter only If there is no key press for 10 seconds the system will exit the program menu without saving the changes Setting the clock Enter the program menu by holding down the Program key for 5 seconds The display will show the current clock setting the minutes will be on solid and the hours will flash Depending on fac tory settings your system may be set to a 24 hour military notation or a regular 12 hour notation Setting the hour Use the Up or Down keys to ad justthe hours AM PM Press the Program or OK key to jump to the next parameter the minutes Setting the minutes Use the Up or Down keys to adjust the minutes Press the Program or OK key to jump to the next parameter the filter start time FS or purge start time PS O Filter cycle frequency The display will show FFxx xx representing the number of filter cycles per day Use the Up or Down key to adjust the frequen

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SGH-M200 Felhasználói kézikönyv    OSMIS WIA Case Management User Manual  Profiler Kit - AxeMotion CNC Controller  Philips Brilliance LCD monitor, LED backlight 231B4LPYCS  Meridian™ user guide  

Copyright © All rights reserved.
Failed to retrieve file