1. LCD shows Er 5 Cuff pressure above 300mmHg LCD shows Er 6 More than 3 minutes with cuff pressure above 15 mmHg LCD shows Er 7 EEPROM accessing error LCD shows Er 8 Device parameter checking error LCD shows Er A Pressure sensor parameter error Measure again after 5 minutes If the monitor is still abnormal please contact the local distributor or the factory No response when you press button or load battery Incorrect operation or strong electromagnetic interference Take out batteries for 5 minutes and then reinstall all batteries 17 Mainte ce 1 Do not drop this blood pressure monitor or subject it to heavy impact 2 Avoid exposure to high temperatures direct sunlight and contact with water 3 If the monitor is stored at temperatures below freezing do not use immediately Leave at room temperature for at least 1 hour before use 4 Do not attempt to disassemble the monitor 5 Do not leave the batteries in the monitor if it is not in use for a long period of time 6 It is recommended the performance should be checked every 2 years or after repair 7 If the monitor becomes dirty please clean it with a soft dry cloth Do not use any abrasive or volatile cleaners 8 The supplier will make available on request the circuit diagrams component part lists descriptions calibration instructions or other information which wi
2. Pe b The monitor will beep when the automatic measurement has finished If there is an error or abnormal reading please refer to the Troubleshooting section What the Results Mean a The LCD screen will automatically display the systolic and diastolic pressure reading in mmHg and the pulse rate in pulse min after each measurement b Record date time systolic reading diastolic reading and pulse rate on your record card which you will find in the pack including anything that may have influenced your blood pressure reading e g stress or anxiety This will help you monitor trends Please take this record card with you on your visits to your doctor pharmacist or healthcare professional Measurements should ideally be taken at the same time under the same conditions and in the same position each time Please be aware that blood pressure can fluctuate since it responds to minute changes in the body It is unusual for it to continuously remain at the same value hence it is recommended that the blood pressure be determined based on an average of multiple measurements If you experience a higher than normal reading do not panic as this can happen Relax and take a break for at least 10 minutes before measuring your blood pressure again Low blood pressure Hypotension and high blood pressure Hypertension can only be diagnosed by a qualified healthcare professional such as a doctor or pharmacist
3. Diastolic mmHg The blood pressure classification table above is intended only to categorize different levels of blood pressure If you are concerned by the results that you obtain consult your doctor Stage 3 Hypertension 180 110 RED 12 Your heart is just like a pump which works all the time to make the blood flow through all of your body s blood vessels Blood pressure measures the force exerted on the wall of the blood vessels by the pressure of the blood The output of blood from the heart when it pushes blood around the body is called systolic blood pressure Diastolic blood pressure is the measurement of the blood returning to the heart 120 systolic Blood pressure is normally written as for example B0 diastolic Fluctuation of Blood Pressure Blood pressure fluctuates constantly during the day Its value in the daytime is higher than in the evening with the lowest level being at midnight The pressure begins to rise again at 03 00am la and reaches its highest level any time during the day so it is gt j amp impossible to get a consistent reading For this reason please take your measurements at the same time of day Q Systolic Diastolic 13 1 Model BPM 3 9 Power source 2 x AAA batteries included 2 Measuring method Oscillometric method automaticinflation 10 Classification Internal powered equipment Type B automaticmeasurement 60 memory functions 11 Pr
4. memory display mode to switch the device off In this mode the device will automatically switch off after 1 minute of inactivity c If there are no results stored in the memory the LCD will show dashes as below picture for both blood pressure readings and for pulse rate Pressing Memory or Start button will switch the device off Clearing the memory Whilst in memory display mode hold down the Memory button for 3 seconds All stored results will be deleted after 3 beeps The LCD will appear as in above picture Shut Down The unit has an automatic switch off mechanism which means it will turn off after 1 minute if not being used 11 The following guidelines for assessing high blood pressure without regard to age or gender have been established by the World Health Organization WHO Please note that other factors e g diabetes obesity smoking etc need to be taken into consideration Consult your doctor for accurate assessment Classification of Blood Pressure for Adults Systolic mmHg 4 BLOOD PRESSURE SBP DBP CLASSIFICATION mmHg mmHg Severe Hypertension 180 Optimal lt 120 lt 80 Moderate Hypertension 160 Normal 120 129 80 84 Mild Hypertension mo igh j 7 High normal BP High Normal 130 139 85 89 RETT Stage 1 Hypertension 140 159 90 99 YELLOW 120 Stage 2 Hypertension 160 179 100 109 ORANGE gt
5. APPROVED By Paul Aylott at 4 42 pm May 05 2011 KINeTIK medical neath monitors for everyone Wrist Type Blood Pressure Monitor gt User Manual BPM Series Introduction gt 2 Parts gt 3 Setting up your Blood Pressure Monitor D 4 5 Clock and Data Adjustment gt 6 Using your Blood Pressure Monitor 2 7 11 Assessing High Blood Pressure for Adults gt 12 Additional Information on Blood Pressure 13 Specification gt 14 Interpretation of Blood Pressure BP Results 5 15 Troubleshooting 5 7 16 17 Maintenance gt 18 Blood Pressure Record Table gt 19 Explanation of Symbols on Unit gt 20 In ctio Thank you for purchasing the Kinetik Medical Wrist Type Blood Pressure Monitor This monitor is an easy to use and accurate way to measure your blood pressure Before you start it is important that you read this instruction manual Blood pressure testing is easy To get the most out of this product please follow the subsequent recommendations We hope you will be satisfied with your Wrist Type Blood Pressure Monitor If you have any questions please contact your local pharmacist or healthcare professional Parts ic BLOOD PRESSURE Systolic EVEL CLASSIFICATION INDICATOR Memory Pulse Diastolic LCD Screen Kinek pulse detected appears during testing Start gt deflate to measure deflate air in cuff N low battery Setting up your Blood Pi Load
6. If you have any concerns or questions please contact your pharmacist or healthcare professional To get an accurate value Measure 1 hour after eating and avoid measuring immediately after bathing s Measure at least 1 hour after smoking or drinking alcohol coffee Relax for 10 20 minutes before taking a measurement and remain relaxed whilst measuring Do not move or talk during measurement as this will affect the accuracy Do not use this monitor if you suffer from atrial or ventricular premature beats or atrial fibrillation 9 Using your Blood Pressur Re measuring If you want to measure again just press the Start button Leave at least 3 minutes between measurements to allow blood circulation to the arm to return to normal Do not measure your blood pressure too many times in 1 session as it may cause discomfort in the arm If you feel any discomfort or pain turn the monitor off and remove the cuff immediately Reading stored results from the memory a Press button Memory when the monitor is off to enter the memory mode The LCD will show the number of results stored then the most recent result will be displayed the 01 in the top left of the LCD is the memory number as in the picture Continue pressing the Memory button to progress through the stored results memory number will increase by 1 each time Using your Blood Pressur b Press Start at any time whilst in
7. ed a We recommend that you carry out your test whilst sitting at a table ensuring the cuff is at the same height as your heart This will place your wrist and the monitor in an ideal position to obtain the best results b Place the cuff on your left wrist Ensure the cuff is secure Do not inflate the cuff when it is not wrapped around the wrist CEREA Patata Mista c Once you are in a comfortable position switch the unit on by pressing Start button The device will beep d After the self verification which takes about 2 seconds the LCD screen will show 0 and begin automatic inflation When automatic inflation begins the unit will inflate to 187mmHg If a pulse is not detected the unit will continue to inflate automatically to the next pressurisation level This will continue to a maximum level of 300mmHg If you feel any discomfort or pain during this time turn the unit off and remove the cuff immediately Consult your local pharmacist or healthcare professional for advice Once automatic inflation begins you can choose to inflate the cuff to the next pressurisation level by pressing the Memory button just before the cuff reaches the pre set pressurisation level Measuring Process a Once the cuff has automatically inflated the LCD screen will display whilst the pressure is gradually reduced and the monitor takes an automatic measurement 11 04 LOL ico P
8. essurisation automatic air inflation by an air pump 3 Wrist cuff size 300mm x 70mm 12 Deflation Automatic exhaust 4 Unit size 92mm x 65mm x 30mm 13 Automatic power off Device automatically switches off 5 Measuring accuracy within 3mmHg after 1 minute of non use to save energy 6 Blood pressure measuring range OmmHg 295mmHg 14 Environmental temperature for using 5 C 40 C 7 Pulse rate range 40 180 min 15 Environmental temperature for storage 20 C 55 C 8 Pulse rate accuracy within 5 16 Environmental humidity for using lt 85 17 Environmental humidity for storage lt 95 This is a Class Ila medical device and fulfils the provisions of the medical devices directive 93 42 EEC Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff stethoscope auscultation method within the limits prescribed by the American National Standard for electronic or automated sphygmomanometers 14 Interpretatio Category of Blood Systolic BP Diastolic BP E Pressure mmHg mmHg Advice on Results Hypotension lt 100 lt 60 Practice a healthy lifestyle Consult your doctor only if suffering symptoms of low BP eg fainting Ideal lt 120 lt 80 Practice a healthy lifestyle Normal 120 129 80 84 Practice a healthy lifestyle High Normal 130 139 85 89 Practice a healthy lifestyle Hypertension 140 159 90 99 Practice a healthy
9. ing Batteries a Open battery cover at the back of the device cover slides off b Insert two AAA batteries observing correct polarity c Close the battery door Non rechargeable batteries are not to be recharged Always remove exhausted batteries from the monitor The supply terminals are not to be short circuited Do not mix old and new batteries or different types of batteries Do not use rechargeable batteries Only batteries of the same or equivalent type as recommended are to be used Batteries must be handled with care under adult supervision If batteries leak and come into contact with skin or eyes wash immediately with copious amounts of water Replacing Batteries When the LCD screen displays low battery an New batteries must be inserted immediately to ensure accurate results Rechargeable batteries with a voltage of 1 2V are not suitable for this product Please dispose of batteries according to battery manufacturer s instructions Setting up your Blood Putting on the Cuff a Place the cuff on bare skin onto the left wrist making sure that the meter body is on the palm side centre of the wrist as in the picture b Place the cuff 1 2cm above the wrist joint c Use your free hand to adjust the tightness of the cuff until it is firm d To ensure the cuff is the correct tightness no tension should be felt on the wrist Please put the cuff on the left wrist Do not wrap the c
10. lifestyle mild Re measure BP monthly over next 3 months If high levels 140 90 persist eg 2 high readings on 2 seperate occasions consult doctor Hypertension 160 179 100 109 Practice a healthy lifestyle moderate Re measure BP monthly over next 4 months If high levels 140 90 persist eg 2 high readings on 2 seperate occasions consult doctor Hypertension 180 219 110 119 Re measure BP in a few days If BP gt 180 110 consult severe doctor Hypertension 2 220 2 120 Visit your doctor or hospital very severe Your BP should be re assessed professionally at least once a year speak to your pharmacist or healthcare professional If systolic BP and diastolic BP fall into different categories the higher value should be taken for classification 15 Abnormality Reason Checkout LCD shows low battery symbol 41 Low Battery Change the batteries LCD shows Er 0 Pressure system is unstable before measurement LCD shows Er1 Fail to detect Systolic pressure LCD shows Er 2 Fail to detect Diastolic pressure Don t move and try again LCD shows Er 3 Pneumatic system blocked or cuff is too tight during inflation LCD shows Er 4 Pneumatic system leakage or cuff is too loose during inflation Apply the cuff correctly and try again 16 ubl foo Abnormality Reason Checkout
11. ll assist the USER s appropriately qualified technical personnel to repair those parts of EQUIPMENT which are designated by the manufacturer as repairable sl Harvard Medical Devices Ltd Unit 1301 2 13th Floor Railway Plaza 39 Chatham Road South Tsimshatsui Kowloon Hong Kong EC REP Kinetik Medical Devices Ltd C ps Yi na Harvard House The Waterfront Elstree Road Elstree Herts WD6 3BS UK 18 Blood Pressure Record T Please log the date time and your SYS Systolic and DIA Diastolic blood pressure levels We recommend you share this information with your Doctor Name Date Time SYS Systolic DIA Diastolic Pulse Rate Comments 19 0197 Les mer This symbol indicates that this product is a Type B device Symbol for Environment Protection Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your local Authority or retailer for recycling advice Symbol for Manufacturer This product complies with MDD93 42 EEC requirements Symbol for European Representative Kinetik BPM3 IB 20110429 20
12. uff too tightly otherwise results will be inaccurate The cuff can be detached and cleaned by hand with warm soapy water Rinse thoroughly with cold water and towel dry To detach the cuff carefully pull it away from the monitor body To reattach push the cuff and monitor body together so that the clips lock in place ensuring it is the correct way around the long part of the cuff should be to the left of the LCD screen DO NOT IRON a Once you install the battery or turn off the monitor it will enter Clock Mode and LCD will display time and date by turns See picture 2 amp 2 1 b While the monitor is in Clock Mode pressing both the Start and Memory button simultaneously a beep is heard and the month will blink at first See picture 2 2 Press the button Start repeatedly the day hour and minute will blink in turn While the number is blinking press the button Memory to increase the number Hold down the button Memory the number will increase fast c You can turn off the monitor by pressing Start button when the minute is blinking then the time and date is confirmed d The monitor will turn off automatically after 1 minute of no operation with the time and date unchanged e Once you change the batteries you should re adjust the time and date 12700 picture 2 I picture 2 1 picture 2 2 Using your Blood Pressu Getting Start