Home

User`s Manual (iRobotics ® 5)

image

Contents

1. USER S MANUAL ROBOTICS 5 The Smart Medical Massager IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance basic precautions should always be followed including the following Read all instructions before using this appliance WARNING To reduce the risk of burns fire electric shock or injury to persons 1 The main power switch is marked with international symbols and I The switch in position I means that system is turned on and the switch in position O means that system is off 2 An appliance should never be left unattended when plugged in Unplug from outlet when not in use and before putting on or taking off parts 3 Close supervision is necessary when this appliance is used by on or near children invalids or disabled persons Keep children away from extended foot support or other similar parts 4 Use this appliance only for its intended use as described in this manual Do not use attachments not recommended by the manufacturer 5 Never operate this appliance if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water Return the appliance to a service center for examination and repair 6 Keep the cord away from heated surfaces 7 Do not use outdoors 8 Do not operate where aerosol spray products are being used or where oxygen is being administered 9 To disconnect turn all controls to the off positio
2. Service Frame Commercial iRobotics 5 Use 6 Months 1 Year 2 Years Commercial iRobotics 6 Use 6 Months 1 Year 2 Years What is NOT covered e This warranty does not cover any loss or damage resulting from improper installation alterations or modifications of original condition or unauthorized repairs e This warranty does not cover damage resulting from improper use of electrical oower supply electrical disturbances and power surges e This warranty does not include any shipping expenses incurred e This warranty does not apply to normal wear and tear including leather or fabric covering by abuse e The warranty does not apply if the product has been damaged physically whether intentionally or accidental or neglect including stains fluids mold water damage animal damage cuts burns loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair and products purchased from unauthorized dealers e This warranty is non transferable and applies only to the original purchaser of this product Implied Warranty e Any implied warranties shall be limited to the duration of the 2 year portion of this warranty for home use and 6 month portion of this warranty for commercial use With regard to structural frame it is limited to the duration of the 5 year portion of this warranty for home use and 6 month portion of this warranty for commercial use e n no case will LURACO be lia
3. MP3 music files to the back of the remote Fig 13 SD card is not included 6 For headphones please insert the headphones to the audio socket as indicated on the back panel of chair Placement There must be enough space around the chair There is a clearance of 80cm or 31 5 inches from the front of the chair to the wall and 60cm or 26 5 inches for the chair backrest ATTENTION Be sure no object is behind chair for reclining For a more gentle massage a gentle massage pad is included Place the pad as shown in photo to the massage chair back cushion Fig 14 Gentle Massage Pad Fig 14 Understanding the Remote Control o VOOR OIO0IO OOOI 8 9 9 07 x fa z D z o Ai I otn e E c rA ZERO UP GRAVITY SHOULDER DOWN VIBRATE V 90 Remote Control Instructions and Button Description QE DAE 4 0 Power Stop This button starts stops the massage system The default mode is Japanese massage The timer for each massage session is 20 minutes When timer is up the chair maintains its position to avoid sleep disruption Pressing this button will put the chair back to its initial position automatically 1 Automatic Massage Modes e Japanese Massage Mode Also known as Shiatsu massage in traditional Japanese This massage style covers the entire body applying varying pressure at different acupuncture points on the back T
4. simultaneously 3 Spot Massage Adjustment Moves mechanism up down to desired vertical position in manual spot massage mode 4 Massage Intensity Adjustment Increases Decreases intensity of entire massage system 5 Shoulder Position Adjustment Engages mechanism to desired shoulder height 6 Vibration Turns On Off vibration mode 7 Zero Gravity Turns On Off Zero Gravity Zero Gravity is a neutral body posture that reclines the body and elevates the feet above the heart It was developed by NASA and has been scientifically proven to put a person into a heightened state of relaxation and well being 8 Foot amp Calf Massage Engages mechanism for the foot and calf massage 9 Back Incline Recline Adjustment Inclines Reclines the back of massage chair 10 Foot Rest Position Adjustment Adjusts the foot rest up and down 11 Zero Gravity Angle Adjustment Adjusts the position of back and feet at the same time 12 MP3 Player Control Play Pause Forward Backward and Volume up down control Massage profile and description Kneading The roller moves in circular motion on both sides of the spine which feels like pressing with the thumb in circular motion like Fig A cord which feels like tapping the muscles with the hand in alternate fashion as shown in Fig B Kneading and Tapping Combo is shown in Fig C Rolling Massage Four circular rollers move up amp down in rhythmic fashion from neck to lower back It feels like a m
5. O NOT use lubricating grease on shaft when connecting arm airbag assembly to arm rest b DO NOT pierce or touch airbag with needle or sharp object c DONOT shake arm airbag forcibly or damage may occur Assembly a Insert half of the arm massage assembly shaft into slider hole and begin to tighten Fig 7 b Repeat the same steps on the other side Both should easily slide for adjustment Fig 8 Loosen the hand wheel by turning left tighten the hand wheel by turning right The hand wheel can be removed from the assembly when it is turned left continuously Fig 7 Fig 8 9 Installation of remote holder and mini cup tray a Remote can be placed on either right or left side Please take out the three screws for mounting Pull back the rubber cap and proceed to screw in remote holder on desired side Place rubber cap flush with the chair wall Fig 9 b Insert Remote to remote holder Note insert from top Fig 10 Fig 9 c Install mini cup tray on to massage chair using three screws already inserted into support Fig 11 OPERATION AFTER ASSEMBLY 1 Plug the power cord to the machine Fig 12 2 Connect the remote to the DB9 port on the back of chair as indicated by back label Fig 12 Fig 12 Fig 13 3 Turn on the power switch on the back Switch to position 4 Use the remote to choose the massage functions and enjoy the comfortable massage 5 For MP3 music player function please insert an SD card with
6. assage therapist firmly moving the hand as shown in Fig D y E E Tapping The roller makes alternate strokes along the spinal 7 A p Cu A Kneading Massage Kneading amp Tapping B Tapping Massage p Rolling Massage Fig A B C D Depiction of different massage modes 12 TROUBLESHOOTING OF MASSAGE CHAIR A Warning Unplug the power cord before attempting any troubleshooting or service LURACO iRobotics 5 massage chairs come with advanced state of the art electronics and software technology which support self diagnostic features to detect the individual failure of critical components in the massage system The Master box has different LED indications which help the user to narrow down the failure trouble shooting if any From the Fig 16 shown below the user can find the LED location in the back of massage chair SELF DIAGNOSTICS SYSTEM STATUS LED Overloaded Up Down Sensors Remote Com EL Nc Trouble Shooting Guide Problem Issue Possible Cause Trouble Shooting Method Power switch is not turned on 1 Turn power switch on the back Bad connection between power plug On Does not work after powered and socket Connect power cord again up Massage remote is not turned on Press power button on remote Have broken power cord or plug Request manufacturer or service Bad fuse technician to replace power cord Control unit does not function Replace the fuse with exact properl
7. ble for incidental or consequential damages whether such damages are claimed on account of breach of warranty breach of contract negligence or strict product liability including without limitation damage to property other than the product or other economic losses e URACO shall not be liable for any personal injury property or any incidental or consequential damages of any kind resulting from malfunctions defects misuse improper installation or alteration of this product Extended Warranty Plan LURACO s massage chair comes with a high expectation in performance and reliability which should last for many years However all products have a defective rate If something does go wrong LURACO can back it up with an available Extended Warranty Plan The Extended Warranty Plan provides customers a full 5 years of comprehensive protection for LURACO s massage chairs For 395 you can rest assured that your massage chair will be taken care of as soon as possible Note Extended warranty plan is only available for home use application only We do not offer this plan for commercial use How to get a warranty service e Customer must provide proof of purchase to claim any warranty e Customer must obtain a return authorization number in order to ship the chair to a service center e Customer may obtain service advice by contacting the LURACO Technologies customer service department toll free at 1 800 483 9930 Important return Instructi
8. ctrical source to avoid shock Clean the cloth surface with neutral detergent or special mild detergent for cloth Dust can be cleaned off with a damp cloth of mild detergent and air dry Do not spray pesticide on device Specified cleaner can be used on the leather plastic and dried with a cloth DO NOT use a damp cloth on the electronic components which can cause shock and damage The leather covers headrest seat cushion foot cushion can be removed for cleaning iIRobotics 5 Parts Controller Holder Seat Cushion Pillow C 7 N C Controller 33 Ve Back Rest Rest 333 if E Casing of Seat Frame INSTALLATION INSTRUCTION 1 Unpack the chair completely Wood brace 3 Under the chair near control box connect both wire 1 and wire 2 to the male female connections Note They can only fit in one way Fig 2 4 Zip up and affix the back pad to the backrest and match the Velcro of leg massager windshield leather and seat leather Velcro and affix in correct position Fig 3 and Fig 4 Fig 2 Fig 3 5 Connect the air tubes Assemble by color coded connections green to green white to white red to red etc Be sure that connections are secure using clamps provided two per connection Fig 5 Fig 4 Fig 5 6 Connect vibration wire Be sure that it is firmly connected Fig 6 Fig 6 7 Place seat cushion in correct position 8 Installation of arm massage Restrictions a D
9. g No adapter should be used with this product ADAPTER GROUNDED OUTLET a an GROUNDED OUTLET BOX A cp GROUNDING screw METAL SCREW GROUNDING PIN AACOD Figure Illustration Grounding A MEDICAL WARNINGS Not recommended for the following people e Pregnant Women e People with distorted joints broken bones skin infection or injury e Children under 12 If you have a medical issue or concern please consult your doctor before using the massage chair Do Not e Do not allow children to play near the chair especially during operation e Donot leave mobility impaired or soeech impaired people alone in chair Additional Safety Precautions e Do not use more than 20 minutes per session Do not place or stock this machine near damp places such as swimming pools or bathrooms Do not press by force on the massage rollers Do not stand on the chair or store heavy items on the chair Do not use in the environment which is dusty greasy or lacking oxygen Do not place near steam oven open fire or heat Wear suitable clothing do not massage with bare skin Do not place directly in the sun Do not use electric blanket while using the massage chair Do not use outdoors Do not use while smoking Place this machine horizontally with space over 80cm enough for full recline mode Place on level floor A EMERGENCY STOP In case of emergency press the power button to stop the system DO NOT operate near young chi
10. hair or under the legs before reclining or lowering the leg massager e Do not put your hands or head under the chair e When using the massage chair ascertain that the footrest is in the lowest position e Do not use immediately after meals e Do not sit on the back cushions armrest or legs e Don t use the massage chair when your body is wet or moist as it can result in electrical shock e Do not operate with more than one person e Don t use when using head ornamentation as it can result in injury e Do not stumble over electrical wires or connections Do Not Use the Chair under the Following Conditions e When the apparatus has been rinsed with water or fails to operate e Power cable is damaged e If you feel abnormal or extremely achy during the course of the massage please stop using the massage chair immediately and consult a doctor Power failure occurs When the massage chair malfunctions during the course of operation Do not touch the inner parts of the chair as this can cause damage and electrical shock Do not dismantle and remove inner parts or repair the massage chair Do not operate during a thunderstorm Methods of Storage e Do not dismount the back of the chair Keep the massage chair free of dust Cover the chair with dust free cloth to prevent dust from collecting Do not store in a hot humid damp place or in direct sunlight or heat Do not store in an overly cold place Cleaning Methods Before cleaning unplug from ele
11. he mechanism performs medium intensity kneading and tapping combinations along with rolling and stretching e Chinese Massage Mode This mode covers the entire body and emphasize on point based massage varying pressure at different points The mechanism performs a combination of medium intensity slow tapping kneading and rolling e Swedish Massage Mode This mode applies gentle massage varying pressure at different points throughout the body which helps in muscle relaxation and blood circulation The mechanism performs slow tapping and kneading along with rolling at regular intervals e Envy Massage Mode The massage style is a combination of all popular massage styles The mechanism performs a combination of soft tapping Kneading rolling and stretching e Thai Massage Mode This mode applies low intensity massage throughout the whole body at specific pressure points This mode also implements stretching to help release muscle strain e Deep Tissue Massage Mode This massage mode is designed to relieve severe tension in the muscle and connecting tissues The mechanism performs hard tapping kneading rolling stretching and vibration rolling throughout the cycle 11 2 Manual Massage Modes e Kneading Turns On Off kneading function e Tapping Turns On Off tapping function e Width This function is available only when tapping is active This adjusts the width of the robotic massage arm e Combo Turns On Off both kneading amp tapping functions
12. into an appropriate outlet that is properly grounded in accordance with all local codes and ordinances DANGER Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded Do not modify the plug provided with the product if it does not fit the outlet have a proper outlet installed by a qualified electrician Followed by either instruction 1 or 2 below 1 This product is for use on a nominal 120V circuit and has a grounding plug that looks like the plug illustrated in sketch A in the Figure pictured A temporary adapter that looks like the adapter illustrated in sketches B and C may be used to connect this plug to a 2 pole receptacle as shown in sketch B if a properly grounded outlet is not available The temporary adapter should be used only until a properly grounded outlet sketch A can be installed by a qualified electrician The green colored rigid ear lug or the like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adapter is used it must be held in place by a metal screw 2 This product is for use on a nominal 120V circuit and has a grounding plug that looks like the plug illustrated in sketch A in the Figure below Make sure that the product is connected to an outlet having the same configuration as the plu
13. ldren DO NOT move the machine during operation 60cm 280cm 1 10in Space requirement 21in 53cm iRobotics 5 Overall Dimensions NOTE Do not use this apparatus as a bed or fall asleep in the course of massage Do not use more than 20 minutes the recommended time of use is 20 minutes Prolonged massaging may cause aches muscle or nerve issues The preferred total duration of massaging within the day should be 30 minutes total or less AN Caution for User e This device should not be used until grounded e For a softer massage a dry towel can be placed on the chair never use an electric blanket note that a gentle massage pad is included e Inthe course of normal use lift the back cushion regularly to check if there is any damage or cracks in the fabric cushion part Please stop using immediately even if there is minor damages turn off the power cable Send the cushion in for repair to avoid possible electric shock e Do move the chair while in use Do not place heavy objects on the armrest foot cushion or back of the chair to avoid turning over the chair or damage to the chair e Do not pull the fabric forcefully or stab it with sharp objects which can result in injury or damage to the chair e Do not move the chair on wooden floor carpet or other easily damaged flooring e Children and pets should not be allowed to play around chair e Please be sure that no people pets or other objects are behind the c
14. n then remove plug from outlet 10 Connect this appliance to a properly grounded outlet only See grounding instructions 11 Do not remove the back cushion and do not play with roller mechanism 12 Do not remove the bottom seat and do not play with actuators 13 Keep the cord out of heavy traffic area To avoid fire hazard NEVER put the cord under rugs or near heat generating devices 14 Always unplug the power cord from the electrical outlet immediately after use and before cleaning 15 Always check the volume before using the headphones 16 Do not operate any equipment with damaged parts 17 Any other use not recommended by the manufacturer may cause electrical shock or injury to persons 18 Do not touch or re wire the wires connected to the master box 19 Do not attempt to repair or adjust any electrical or mechanical functions on this unit Doing so will void the warranty After reading this owner s guide if you have any questions or comments please call 1 817 633 1080 or contact our technical support department at support luraco com or visit our website at www luraco com for more information GROUNDING INSTRUCTIONS This product must be grounded If it should malfunction or breakdown grounding provides a path of least resistance for electric current to flow thus reducing the risk of electric shock This product is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged
15. ologies Right to make changes LURACO Technologies reserves the right to make changes to information published in this document including without limitation specifications and product descriptions at any time and without notice This document supersedes and replaces all information supplied prior to the publication hereot Suitability for use LURACO Technologies products are not designed authorized or warranted to be suitable for use in life support life critical or safety critical systems or equipment nor in applications where failure or malfunction of aLURACO Technologies product can reasonably be expected to result in personal injury death or severe property or environmental damage LURACO Technologies accepts no liability for inclusion and or use of LURACO Technologies products in such equipment or applications and therefore such inclusion and or use are at the customer s own risk 17 THANK YOU FOR BUYING LURACO TECHNOLOGIES PRODUCTS LURACO TECHNOLOGIES INC 1132 107 STREET ARLINGTON TX 76011 USA TEL 1 817 633 1080 FAX 1 817 633 1085 WWW LURACO COM
16. on Automatic Timer Shut Off 20 Minutes Full Length Travel 75 cm 29 52 inches Leg rest adjustment Accessories Power cord Headphones MAINTENANCE INSTRUCTION This product does not require any lubrication for the mechanical parts in the system Use only leather care products for cleaning and maintaining the leather WARRANTY INFORMATION Introduction LURACO Technologies is dedicated to offering our valued customers the best massage chair buying experience available As part of this commitment the company works very hard to provide customers with the best warranty plan available We guarantee that defective massage chairs will be repaired or replaced during the effective warranty period What is covered in this Warranty a For Home Use This warranty includes part costs and labor for the first 2 years at no cost to the customer This warranty includes part costs covered for the third year at no cost to the customer Structural frame carries an additional two 2 year warranty for a total five 5 years Application In Home Structural Service Frame zivears aleas _5 ears pva seas b For Commercial Use This warranty includes part costs and labor for the first 6 months at no cost to the customer This warranty includes part costs covered for the first year at no cost to the customer Structural frame carries an additional two 1 year warranty for a total two 2 years Application In Home Structural
17. ons If you need to send a unit to Luraco Technologies for repair please follow the steps below 1 Carefully pack the item in its original carton or other suitable box to avoid damage in shipping 2 Before packing your unit be sure to enclose A Your name with full shipping address and telephone number B Dated receipt for PROOF OF PURCHASE Attach documentation detailing the problem you are having with your device 16 Disclaimers Limited warranty and liability Information in this document is believed to be accurate and reliable However LURACO Technologies does not give any representations or warranties expressed or implied as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information In no event shall LURACO Technologies be liable for any indirect incidental punitive special or consequential damages including without limitation lost profits lost savings business interruption costs related to the removal or replacement of any products or rework charges whether or not such damages are based on tort including negligence warranty breach of contract or any other legal theory Notwithstanding any damages that customer might incur for any reason whatsoever LURACO Technologies aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the terms and conditions of commercial sale of LURACO Techn
18. y specifications Contact Technical Support of the manufacturer if it continues Sounds like tapping or Sounds from air pump motor or other Normal phenomenon humming sounds mechanical parts Roller height changes Rollers work alternately Normal phenomenon 1 Cut down on usage no more than Abnormal sounds while Maybe from over working the massage 20 minutes per session working mechanism 2 Contact Technical Support of the manufacturer if it continues 1 Bad power connection 1 unplug and reinsert power cord to Suddenly stops working 2 Auto program timer is up the chair 2 Normal operation Ganmmebreclineditec har Obstruction be sure that chair is Stop chair operation and move allowed enough room to fully recline obstruction Can not restore position after Contact Technical Support of the reclining manufacturer if it continues Remote control is hot or overheats Over recommended usage Use only 20 minutes per session 1 Cut down usage no more than 20 1 System is overloaded minutes per session Abnormal overheating from 2 Other unknown causes 2 Contact Technical Support of the power wire or plug manufacturer if it continues If problems are not from the above reasons please turn off power supply and contact the distributor or manufacturer for assistance Attention iRobotics 5 Specifications Maximum user weight 300 Ibs Power Consumption 200 Watts Max Recline Angle 120 170 Degrees Programmed Functi

Download Pdf Manuals

image

Related Search

Related Contents

Manuale Uso e Manutenzione  Manual curso técnico comercial  Mosys, Manual de Instrucciones, 2013  Eglo 90342A Installation Guide  LevelOne 125M SMF SFP Transceiver, 20km, 1550nm, -40 ~ 85C  install/removal instructions: window regulator  RC11E Radio Remote - Side  取扱説明言`  BR2218CH User Manual - Oriental Pacific International  Mode d'emploi  

Copyright © All rights reserved.
Failed to retrieve file