1.  the type of functioning of the TRIP relay  in position 1 the relay is energized at rest   FAIL SAFE   in position O the relay is de energized at rest   f selection of the type of functioning of the ALARM relay  in position 1 the relay is energized at rest   FAIL SAFE   in position O the relay is de energized at rest       IM208 U v1 01 pag  2 4    WIRING DIAGRAMS    Example of wiring diagram with switch  SUPPLY with opening coil with output relay  N L1L2L3 energized  fail safe off                              l   l     X  L                            The output contacts can be   used to signal the relay   tripped    The ALARM relay allows   ouput relay ouput relay to signal the current besides  AL    ARED TRIP the 60  of threshold set                                      if ALARM ON is selected      test remote  input signal RESET  current output  auto reset  E L R 2                           power supply Vaux  connection at toroidal current transformer  connection contacts output relay   terminals 11 12 terminals 7 8 9 of TRIP relay   ELR 2 230 to connect at measure coil the contact 7 8 is normally closed if     terminals 1 2   100 125V ca terminals 13 14 FAIL SAFE OFF is selected or without     terminals 2  3   220 240V ca to connect at test coil power supply     terminals 1 3   380 415V ca with FAIL SAFE TRIP ON the contact will  connection reset at distance or automatic be normally opened in condition of rest   ELR2 115 reset     terminals 1 2   100 125V ca cc terminals 
2. 15 16 terminals 4 5 6 of ALARM relay  TRIP2   to connect at a external botton with contact the contact 4 5 is normally closed if   FLR 2 24 normally open FAIL SAFE OFF is selected or without   z   _9  to realize the function of automatic reset  to power supply   ee ee short circuit the terminals with FAIL SAFE ALARM ON the contact will   be normally opened in condition of rest       FUNCTIONALITY   When the device is installed and correctly supplied  its green LED will be on and the output relays commuted if the  functions FAIL SAFE ON  relays normally energized  are selected  The eventual trip of relays can depend by an  interruption of the toroid   relay circuit or by a presence of earth leakage current higher than the value set    The function FAIL SAFE allows the commutation of output relay  besides at the normal intervention for the overcoming of  the current threshold  also for damage of relay or for absence of power supply    When the instrument switch on  the relays will commute  normally energized   after in the condition of trip or if the power  supply is absent the relays come back de energized    If the ALARM ON is set  the ALARM  TRIP2  output relay will commute when the current measured reach the 60  of the  threshold set  in this way it   s possible to have a signalling of increase of the earth leakage current  but not yet at the level  to need the opening of the line under control  If the ALARM OFF is set  the two output relays will commute together  in the  w
3. INSTALLATION   Only a qualified technician can do the installation  The instrument installation must be done in total absence of voltage   The instrument must be intact and it haven   t damages caused of transport  The power supply must be compatible with the  tool range  To fix the device at the panel  insert the two bracket into apposite button holes in the side of the enclosure and  to shut the screw  The transparent cover is fixed at the upper part at joint  To remove the cover it   s necessary to act on  the two hooks in a side of the frontal part of the instrument with a screwdriver    The wire of connection between the relay and the toroidal current transformer must be twisted or shielded in presence of  strong electromagnetic noises or considerable length  It   s better to use a cable with a section of 1 mm    and a length lower  than 30 meters  The toroidal current transformer must be connected at the terminals 1 2  coil of measure  and the  terminals 3 4  coil of test  for the function of test    The relay trip if the connection is interrupted  function of permanent control of the efficiency of the connection circuit   To  test the device it   s possible to use the bottom of TEST that caused the intervention of relay after the delay set        ELR 2 instruction manual IM208 U v1 01 pag  1 4    ELR 2    DESCRIPTION     PROGRAMMING    Earth leakage Relay  rel   differenziale di terra          t  sec          T    El  a  i  s  H    FAIL SAFE    Legenda    1  current tr
4. INSTRUCTION MANUAL    IM208 U v1 01       E LR 2 EARTH LEAKAGE RELAY    GENERALITY   The device type ELR 2 is an amperometric relay of maximum  homopolar differential current to use to control the insulation  towards earth of networks of energy supplier  of electric  machines  etc    The device must be joined at a suitable toroidal current    transformer of the CT line in the way to point out the earth cme dt  leakage current of the system to control and to protect  The  toroidal current transformer point out the vectorial sum of the  currents present on the active conductor of single phase line   three phase with or without neutral  inside the toroidal current  transformer will pass all phase conductor and if present the  neutral  but none protection conductor must pass   in the way  to point up the leakage current towards earth  depend of the  insulation level line under control    When the current read exceed the threshold value set the two  exchanging contacts  available in output  will commute in the  way to protect the line under control using opportune opening  coils switch or contactor or to signal at distance the low  insulation condition of the line or equipment under control     INTRODUCTION  The ELR 2 has standard dimensions DIN 96x96mm with depth very limited  in the way to use it in application where the  space available is limited    A wide range of current and time of delay calibration  allows to use it in a lot of application  both like signalling of low  ins
5. ay to use a contact for the opening the switch jointed and the other for a signalling at distance of tripping relay    To realize the automatic reset it   s necessary to short circuit the terminals 15 16  in the way that if the current measured  descend under the level of the threshold set  the relay will rearm automatically  If after the trip the power supply  disappears  the relay will rearm automatically  If it   s impossible to rearm the relay depends by a current measured upper  than the threshold or the connection between relay and toroidal current transformer is interrupted     ELR 2 instruction manual IM208 U v1 01 pag  3 4    TECHNICAL FEATURES    Auxiliary power supply  Maximum consumption    Current tripping adjustment range IAn    Tripping time adjustment range t    Signalling   Alarm tripping   External toroidal current transformer and  accessories   Output relay  voltage free contacts    Functions programmable    Working temperature  Storing temperature  Relative humidity  Insulation test  Position of mounting  Type of connection  Protection degree  Mounting DIN 43700    Standards    Electromagnetic compatibility    DIMENSIONS          ELR 2 230  100 125V 220 240V 380 415V 50 60Hz  10   ELR 2 115  100 125V cc dc 50 60Hz  10   ELR 2 24  24 48Vcc de 50 60Hz  20     0 025 0 25A forK 0 1  0 25 2 5A forK 1  2 5 25A forK 10   0 02   0 5 sec  for K  1  0 2 5sec  for K  10       TR    serie    function alarm output  function fail safe for both outputs   automatic  exter
6. ipping setting potentiometer   2  tripping time setting potentiometer   3  push button for test   4  push button for manual reset   5  signalling green LED for auxiliary supply  presence   6  signalling yellow LED of alarm tripped   7  signalling red LED of relay tripped   8  screw terminals for the connection of the  power supply and contacts of output relays   9  screw terminals for the connection at the  toroidal current transformer and for the  reset at distance or automatic    instruction manual    REAR PANEL             QQOOOO  45 sn    CE    005A Mane in ITALY                                                    D ELR 2M 230   ELR 2M 24   ELR 2M 115  D ELR 2 230  D ELR 2 24   ELR 2 115             V aux    1 2  115V ac  2 3   230V ac  1 3 400Vac    V aux  V  4 2 24Vacide 4 2   115V acide  4  3   48V acide       ouput relay ouput relay  Vax y Al TRIP   TRIP 2                                   2 3 4 5 6 7 8 9    SSIS                                              alarm on  tx1    t IAx0 1    off  off                FAIL SAFE    10  microiswitches of programming    a  selection of the activation alarm function  in position 1 the alarm function is disabled  in position 0 the alarm function is enabled   b  selection of the multiplying constant of tripping time  in position 1 K 10  in position 0 K 1   c d selection of the multiplying constant of tripping current  with c d in position 0 K 0 1  with c in position 1  d in position 0 K 1  with c d in position 1 K 10   e selection of
7. nal reset  or manual reset  2 5 kV 60 sec     CEI 41 1 IEC 255 VDE0664 IEC755 CEI 64 8  EN 61008 1  1999 11   EN 62020  1999 09   EN 61543  1996   09   EN61326 1  1998 04  EN 61326 A1  1999 05     CEI EN 50081 1 CEI EN 50082 2                                                                   Contact the technical assistance or refer at specific document for applications don   t described in this manual     NOTE    At reason of the evolution of standards and products  the company reserves to modify in every time the features of the product described in this    document  that it   s necessary to verify preventively     The liability of the producer for damage caused by defect of the product    can be reduced or deleted       when the damage is caused joint by a defect of  product or for blame of the damaged or a person of which the damaged is responsible     Article 8  85 374 CEE      contrell elettronica srl      26900 Lodi   ITALY   Via S  Fereolo  9    Tel   39 0371 30207   30761 Fax  39 0371 32819  http   www contrel it   E mail  contrel contrel it    ELR 2 instruction manual    IM208 U v1 01 pag  4 4    
8. ulation and like protection line according with the norms  CEI 64 8   to realize adequate vertical and horizontal  selectivity  etc    The device has  on input circuits of the measure circuit opportune filters doing it exempt by external noises  permanent  control function of efficiency of internal circuit  permanent control of connection between relay and toroidal current  transformer and coil continuity with test at 4 wires  in the way to verify the efficiency of system relay   toroidal current  transformer  The functioning is insured also with sinusoidal current and unidirectional button  type A according to norms  IEC 755     On the front it   s possible to program the tripping current  25mA   25 A   the tripping delay  0 02   5 sec    the activation of  the alarm threshold and the type of functioning of output relays  The device has two contacts in exchange in output for  tripping and prealarm  both for the application with a closed contact and opened contact   the possibility of functioning  with the manual or automatic reset  the connection for eventually bottom of reset at distance  an apposite transparent  cover of frontal protection and lateral screw terminals     MODELS    In basis of power supply there are three models     ELR 2 230  100 125Vca   220 240Vca   380 415Vca    ELR 2 24  24V calcc   48V ca cc    ELR 2 110  100 125V ca cc   On request are available others power supplies     ACCESSORIES AND OPTION  accessories  transparent cover of frontal protection    
    