Home
miniOMNIAlog User Manual EN_02_14
Contents
1. After a few seconds the screen for the successful installation of the modem will be displayed Add Hardware Wizard Instali New Modem Modem installation is finished Your modem has been set up successtully ff you want to change these settings double click the Phone and Modem Options icon in Control Panel click the Modems tab select this modem and then click Properties Click on Finish to end the first part of the setup rf Rev 2 26 02 2014 Page 31 of 68 MICROSOFT WINDOWS MODEM PARAMETERS SETUP Inthe menu Modem you can find the new modem just installed or the PC internal modem ci Phone and Modem Attached 10 Standard 56000 bps Modem COMA Select the modem and then click on Properties lt 4 Phone and Modem sai Attached To Standard 56000 bps Modem COM4 Rev 2 26 02 2014 Page 32 of 68 In the screen that will be displayed it is necessary to press on Change settings Standard 56000 bps Modem Properties odem Diagnostics Advanced Driver Details Events Lr Standard 56000 bps Modem Device type Modems Manufacturer Standard Modem Types Location Unknown Device status This device is working property OK Cancel The same screen will be displayed and now you can change the settings Select Modem Standard 56000 bps Modem Properties General Meden agnosie Advanced Driver Details Events Port COM4 Sp
2. Ee RemoteApp and Desktop Connections Storage Spaces Ein Taskbar lb Windows 7 File Recovery ES Windows Mobility Center Properties Apply Page 29 of 68 The screen Add Hardware Wizard will be displayed Add Hardware Wizard Install New Modem Do you want Windows to detect your modem Windows will now try to detect your modem Before continuing you should 1 the modem is attached to your computer make sure it is tumed on 2 Quit any programs that may be using the modem Click Next when you are ready to continue Flag Don t detect my modem will select it from a list and click on Next gt Add Hardware Wizard Install New Modem Select the manufacturer and model of your modem If your modem is not listed or if you have an installation disk click Have Disk Manufacturer Models Standard Modem Types F 5 7 Eal This driver is digitally signed Tell me why driver signing is important Select in the field Models Standard 56000 bps Modem and click Next gt Rev 2 26 02 2014 Page 30 of 68 rr fe A Add Hardware Wizard Install New Modem Select the port s you want to install the modem on You have selected the following modem Standard 56000 bps Modem On which ports do you want to install it an aL In the screen select the COM port where the modem is connected Click on Next gt
3. letter E followed by a number means an error in operations when sleep state is on the display is off to awake the system up you have to press a key To turn on the system you have to press the key a second time now miniOMNIAlog is totally on and displays the first entry of the main menu APRIRE en in j Dn nn ed Li EN State Menu 1 If you press Enter key in correspondence to the miniOMNIAlog state menu 1 entry the miniOMNIAlog will display the current state MiniOMNIAlog Display code Description state RUN r miniOMNIAlog in run CONFIG C miniOMNIAlog in configuration STOP S miniOMNIAlog in stop fe vs RUN mode CONFIG mode STOP mode The user can read the miniOMNIAlog state when he enters the menu As the user enters the miniOMNIAlog state a 15 sec timeout begins After that the miniOMNIAlog will come back to main menu and will start the timeout display At timeout display expiration the display will turn off While the menu shows the display state Select key causes the display returning back to main menu and timeout reset display Battery Menu 2 If you press Enter key in correspondence to the Battery menu entry 2 the miniOMNIAlog will display the batteries charge state Here follows the battery
4. Lock the SIM slot NOTE the antenna connector is very delicate pay attention to not damage its cable CAUTION TO BE TAKEN WITH 2G GSM GPRS MODEM In case miniOMNIAlog sends measures or alarms by e mail or on FTP server the user has to take into account that the USB serial of communication is shared with the 2G GSM GPRS modem serial of communication For this reason if the user launches miniOMNIAlog from webpages the PC automatically disconnects If the user connects later miniOMNIAlog is automatically put in STOP mode Therefore it will be possible to surf the pages Furthermore it is impossible to visualize the measures in automatic update in page VISUALIZATION MEASURES NOTE SISGEO suggests during installation to not enable e mail or data transmission on FTP server both measures and alarms Once the user has verified the accuracy of readings it is possible to enable e mail or data transmission on FTP server APN configuration On the miniOMNIAlog web server you can find a page where you have to edit an APN command This command is necessary to configure the 2G GSM GPRS modem with the correct parameters according to the selected SIM these parameters depend on your ISP On the miniOMNIAlog web server select the Advanced page from the left menu select the Connection page Inthe Connection page you have to o write the APN of your Internet Service Provider ISP in the APN field e g web omnitel it
5. NOTE if in place of APN there is the field AT command initialization it is necessary to insert the following command CGDCONT 1 IP APN e g CGDCONT 1 IP web omnitel it o write the telephone number in Telephone Number field to establish a GPRS connection Usually the number is 99 1 connection using the default CID 1 overrode with the AT CGDCONT command o write the Username and Password according to your ISP parameter Press Save Changes to confirm the modifications Reboot miniOMNIAlog to make the changes effective WEB PAGES FUNCTIONALITY NOTE The uploading speed of pages could be very slow especially at first access This occurs because the browser hasn t memorized the web pages in its cache yet You have to wait until the pages are completely loaded without repeatedly refresh the page Here you can find a brief description of the main miniOMNIAlog web pages Web pages are the same of OMNIAlog pages or fields cannot be modified STATUS Shows miniOMNIAlog status In this page is shown the current miniOMNIAlog mode Run miniOMNIAlog is set and started It will start acquisitions according to selected configuration Config miniOMNIAlog is in configuration mode No acquisition is in progress In this mode it is possible to modify configuration parameters channel configurations acquisition time etc delete and download logs Only Admin user can modify the Conf
6. Internet pureneenazezeasezeonazeeneeoneeeneonaaeeneeezearaneezanezaeeenienazenazezzesezzenazeoneeezeaeane zzare nas ezearaneazenezeeezeeezazizeaaneeeazenazeneeaeneonasezazeeneanazeoneseneseneeezasenas enne saneonee gt Browse the Internet now gt Set up a new connection anyway Cancel n the following screen select Dial Up 3 Connect to the Internet How do you want to connect _ Broadband PPPoE Connect using DSL or cable that requires a user name and password Cancel mm rf Rev 2 26 02 2014 Page 38 of 68 In the last screen In the field Dial Up phone number enter 0000 Username and Password fields for the moment leave them blank Connection name field enter a name to identify the connection e g miniOMNIAlog Dial up Connection 4 Puta flag in Allow other people to use this connection a Connect to the Internet Type the information from your Internet service provider ISP Dial up phone number Dialing Rules User name Name your ISP gave you Pascali Password your ISP gave you Show characters L Remember this password Connection name OMNIAlog Dial up Connection hl Allow other people to use this connection This option allows anyone with access to this computer to use this connection don t have an ISP Cancel Click on Connect the modem will try to connect Since not all the parameters are set the connection process will fail You can click
7. This IP could be utilized only to use the web server on USB communication After the connection miniOMNIAlog asks for the access credentials NOTES miniOMNIAlog is compatible with the main internet browsers FireFox IE9 Safari Chrome SISGEO recommends the use of FireFox to manage miniOMNIAlog First page upload can take some time Following there are the default credentials al a User Admin User User User Admin User User Psw Admin Deus User INSTALLATION PROCEDURE You can use the four holes 6mm to fix the miniOMNIAlog according to your application Screws and anchor plugs suggested 5mm are not supplied SISGEO rf __Rev 2 26 02 2014 Page 8 of 68 GROUND SYSTEM The protections integrated in the miniOMNIAlog system work correctly only if connected to the ground Use an appropriate green yellow conductor to connect the plug to the ground as shown below The ground system must be designed manufactured and certified according to the rules and laws in force HOW to OPEN miniOMNIAlog Case To open the miniOMNIAlog case use a little screwdriver insert the screwdriver into the hole in the yellow plastic and press down to unlock the case miniOMNIAlog POWER SUPPLY miniOMNIAlog is powered by e 6AAnon rechargeable batteries or e an external power supply i e solar panel Here below are shown the clamps where the power supply is connected Respect the polarity To p
8. losses could happen and these could damage the miniOMNIAlog DISPLAY AND KEYBOARD FUNCTIONALITY miniOMNIAlog is provided with a 7 segment display and 2 input keys Select Enter The display is started by pressing down one of the 2 keys You can scroll the menu using Select key If the user doesn t send any input in a time equal to Timeout Display configured in Energy Management web page the display will turn off and the miniOMNIAlog will return in Sleep state 7 SEGMENT DISPLAY KEYBOARD SELECT KEY ENTER KEY rs x pan Z Lat wv lt AA TUTT Tinm This is the chart of states on display Item Menu Display Code Description Test signal A Tests and shows the 2G GSM GPRS modem signal from 0 modem to 3 State 1 It shows miniOMNIAlog state Battery 2 It shows battery state Firmware 3 It allows miniOMNIAlog firmware updating update Copy Data 4 It copies logs on USB drive Start 5 It starts the miniOMNIAlog Stop 6 It stops the miniOMNIAlog Firmware Ver 7 It shows the firmware version USB 8 It enables the miniOMNIAlog to PC connection Connection Power Off EA it permit to power off miniOMNIAlog properly This chapter summarizes the general philosophy of display messages as follows each code is univocal so for example 1 always identifies the miniOMNIAlog STATE menu letter A is used as a message of successful operation
9. miniOMNIAlog a 4GB pen drive already FAT32 formatted and suitable for miniOMNIAlog reading the USB pen drive can include other files In case of problems during the firmware download from SISGEO website or temporary unavailability It is possible to request the new firmware version contacting SISGEO assistance at assistance sisgeo com Notes and remarks 1 The USB flash drive used for the firmware update must be FAT32 formatted Otherwise the pen drive will not be read from miniOMNIAlog and it will be impossible to update the firmware 2 Itis necessary to copy the whole content of the ZIP file WEB folders FW and Restore directly in the main directory of the USB pen drive do not use sub folders NOTE SISGEO suggests to use a USB flash drive only for this purpose in order to avoid any unexpected data loss C FIRMWARE UPDATE According to the value modified in the firmware version x yy zz it is necessary to proceed in different ways You have two different options Update without database structure modification x value doesn t change while values yy and or zz change Update with database structure modification Value x changes In case of Update with database structure modification the old configuration is not compatible with the new version of firmware Also the log files Measures Events and Alarms must be deleted after firmware update If these logs are not deleted there is the
10. or Select key to go back to main menu 2 shows error if files copy failed for a time equal to timeout and then resets After reset the miniOMNIAlog will go to its normal state 3 resets and starts bootloader for firmware updating if files copy was successful flashing b letter will appear during firmware reprogramming After firmware updating two things can happen firmware updating was successful letter A is showed for a time equal to timeout and after that miniOMNIAlog goes to the normal state I firmware updating failed the miniOMNIAlog restores old versions from web and resets letter E is showed for 15 sec Di LL E LI NOTE after firmware update to communicate with miniOMNIAlog you have to unplug and re plug the power supply Set USB flash drive for miniOMNIAlog firmware update SISGEO strongly recommends to keep miniOMNIAlog updated to the last firmware version available to ensure the best performances to solve any bugs or to implement any improvements and to exploit miniOMNIAlog possibilities NOTE the code structure x yy zz of the firmware version is modified according to the improvement corrections importance carried out between two versions When the value x is modified it means that the improvement modification is of high importance because it changes data structure In this case you need to proceed as explained in chapter Update with database structure modification A CHECK NE
11. possibility to obtain wrong CSV files after the first download Data Copy Menu 4 NOTE miniOMNIAlog should be in Stop or Config state before using this function If you press Enter key in correspondence to the menu entry Data Copy 4 the miniOMNIAlog copies all logs on USB Drive Flashing number 8 is displayed during files copy At the end of the copy flashing number 0 will be shown to indicate to the user to remove USB flash drive and after that letter A if copy was successful If an error occurred the system will go to error state and an error code will be shown Se WARNING it is not possible to connect USB hard drives to this port because these devices need too much current to work correctly In addition it is not possible to connect to this port any device different from flash drive i e Bluetooth key internet key ect At copy process completed a 15 sec timeout starts After that the miniOMNIAlog will come back to main menu and will start the timeout display it can be set up from the web At timeout display expiration the display will turn off While the menu shows the copy state error code or OK Select key causes the display back to main menu and timeout reset display While the menu shows the copy result Enter key causes the timeout reset from 15 sec Ei LI LI Export File Measure and Measure Log Format With miniOMNIAlog you can download data mea
12. select the right remote connection and the correct virtual mode for communicate with the dial up call miniOMNIAlog Make sure you select menu n 8 to set up miniOMNIAlog to communicate by USB Make sure that miniOMNIAlog shows on its display a flashing 1 after the selection of menu n 8 If on the miniOMNIAlog display appears a flashing A it is necessary to wait until the end of the sensor reading and that it shows a flashing O on its display Loss of connection PC In case of an acquisition with the transmission of e mail or FTP the connection is miniOMNIAlog interrupted because the communication socket is shared between USB communication and the 2G GSM GPRS modem Digitized sensors can t Make sure you disconnect the USB cable If miniOMNIAlog is connected to an USB be read cable the energy supplied by the cable is not sufficient to feed the digitized sensors Technical Datasheet CPU AND MEMORY Processor RARI Memory Mass storage Clock accuracy Onboard sensors INPUT Analog differential inputs Datel input INTERFACES Dasplay amp Keyboard senal part USB Host USE Device RS4SS GSMAGPES module ogtional Rev 2 26 02 2014 ARM Cortex MG MCU wath 1 MB Flash 20 MHr CPU ART Accelerator Ethernet 178 Kbyte internal RAM 20 CARD 2 GB for data labout 6 Mega data pointe and WEB pages Hagh precion RTC real time clock with battery back up self compensated n temperature Gppm
13. 2 Ch3 or Ch3 Ch4 are necessary to read the instrument N N p f f re YL Rev 2 26 02 2014 N CEY SISGEO Page 57 of 68 Potentiometer Potentiometer 3wires SINGLE External Power Supply CH 1 4 B GND PWR 3 ONLY for EXT POWER SUPPLY 9 PWR Do not connect with ext power supply Digitalized Instruments Digitized Instruments chain Direct connection vv n DATA a J i p DATA 8 i 3 _ V 5 GND PWR gt SISGEO Rev 2 26 02 2014 Page 58 of 68 Relay Output volt free closure On the miniOMNIAlog board there is one clamp for the relay output for alarm etc managed from the software The relay output is a volt free closure low voltage 30V 1A T Te Le t von M0 aa a3 Mare ibsan 4 a Me ET _ Ti Relay Output Note The relay output change for 1 minute Anomalies and Alarm Warnings Error Codes When the miniOMNIAlog is in error status it shows the letter E and error codes one after the other Following there are miniOMNIAlog error codes EQ General Communication or FTP MAIL connection Error It refers to log events on web server USB Drive not found The system shows general error codes because it has a simple display and so it would be difficult to encode each case The system will log the event error and it will be visible and downloadable from the web Icons and po
14. 25 C 10ppm 30_ APC Temperature measured on the electronic board isccursoy B differentials channels individually configured st factory Each channel ts sbie to acquire data from the following sensors Ma 4 20 m curreni loop C varesi Mo 1 4 20 mA 3 4 wiros Ma Voltage bd wares Ma Vibrating wire hot Thermisior No 1 Vibrating wire Thermastor Maf Wiheatstonbridge 6 wares utlicce No 2 channels one chain of Sisgeo ASABE digtized sensors 7 segment LED display and two selection keys for the minimal local management without PC device status data dovniosd and Feb pages update by USB pan drive Onfy for GSRIVGPRS internal module connection USB 2 0 full speed Type A connector SV max 500 m pen dnye only FAT 16 or FAT 32 USA 2 0 full speed Mini B connector BV max 500 mA FC connection only 6 screw damp DCE port for SISGEO digitized sensors connector Communication interface HS4B6 Communication protocol MODELS ATU The voltage V CUT is switched on and off from the software V OUT is the unregulated power supply input VIN 7 Al Fossar supply management always on or energy sate Ouad band ESSM 850 900 1800 900 MHz GPRS class 10 integrated SIM holder Extended tempersture range 40 to 85C Stubby antenna vath SMA connector Page 62 of 68 ANALOG MEASUREMENTS Miasasurement rate NR ADC Wieasure type and power supply configured at factory Reading resolution Measurement scourecy Te
15. 46 47 47 48 49 50 51 51 52 52 53 54 59 59 61 61 62 66 67 Provisions Install OMNIAlog in order to avoid the direct sun radiation The product should not be installed in small places and or without ventilation with high humidity levels or in the presence of flammable or explosive liquids Do not open the box with bad weather conditions rain snow etc or if you want to avoid the entry of humid air miniOMNIAlog was programmed to work at temperatures between 30 C and 60 C batteries from 20 C to 60 C and to be conserved at temperatures between 40 C e 85 C batteries from 0 C to 40 C Too extreme temperatures can temporarily shorten batteries lifetime or cause the temporary malfunctioning of miniOMNIAlog After tightening the cable glands consider to seal accurately the instrumental cables with silicone or expanded lather to guarantee the correct degree of protection of the box Electrical connections must be done by a qualified technician respecting the current regulations Before doing works verify that all connections also the ones free from potential are voltage free Maintenance works have to be done only by qualified technicians Periodically verify the voltage of the external battery in case of a value inferior to 11 5Vdc consider the substitution of the battery and check on the causes Anyway battery has to be substituted after 5 years If
16. Open any internet browser and enter the IP address 192 168 125 1 You will be requested the miniOMNIAlog log in and you can browse in its pages NOTE the 192 168 125 1 IP address cant be changed by the user USB connection by USB Isolator Cable USB port in miniOMNIAlog is not isolated For the connection between PC and miniOMNIAlog SISGEO recommends the use of an isolated USB cable r 1 s Pi ae Lo te n bpa i DI E 7 rn i E Pais m EER re en i So dl The USB isolator cable effects a potential decoupling of all USB connections It is the professional tool to avoid and fight ground loops and equalize currents It is also important to protect the system against overvoltage that could damage miniOMNIAlog or cause flood readings USB isolated cable is especially recommended when the PC and miniOMNIAlog are connected to the main electricity network If you are using this cable you need to consider that the maximum supplied current is 400mA compared to a USB port that provides 500mA maximal 400mA sourced from the 500mA primary input Therefore when miniOMNIAlog is powered using an isolated USB cable it should be noted that the USB port of the PC must be capable of delivering at least 5OOMA current the connected sensor must not draw more than 35mA If these two conditions are not respected you may experience some communication and power supply disconnections ziale HOW to disconn
17. W FIRMWARE AVAILABILITY To check for any firmware update you have two possibilities Automatic check only with miniOMNIAlog connected to internet COMING SOON Manual check on SISGEO website www sisgeo com Automatic check happens only when miniOMNIAlog is connected to internet through internal 2G GSM GPRS modem miniOMNIAlog is programmed to check every 7 days for any new firmware version When a new version is found the status icon will become red The user through miniOMNIAlog web pages will be informed that on SISGEO website a new version is available This new version must be downloaded to proceed with the update Do New firmware available icon N No new firmware available icon It is possible to check anytime for new firmware on SISGEO website B NEW FIRMWARE DOWNLOAD For both possibilities the download must be performed manually on a PC connected to internet Connect to SISGEO website and in the page PRODUCTS choose Readout Units and Dataloggers Select miniOMNIAlog datalogger from the list Inthe right higher part select Download Firmware the download of the zip file will start Once the download ends you will have on the PC a file called FW x yy zz where x is the major release yy is the web pages version and zz is the firmware version t is necessary to extract the zip file content in the main directory of an USB flash drive SISGEO supplies with
18. a N if Pr a N UN ife r W lt A RO Po x N ee sa Fe N 1 DT TAS mna N iN t N hS 4 7 p NAG Th 4 I N 4 n i N 4 20mA Current Loop 2 wires 4 20 mA Current Loop 2 wires SINGLE External Power Supply SISGEO e Do not connect with ext power supply GNDPWR 4 20mA Transmitter 3 4 wires 4 20 mA Transmitter 3 4 wires SINGLE External Power Supply GND Signal Do no connect with 3 wires SISGEO e Do not connect with ext power supply e Onlyfor3 wiresinstrument Page 55 of 68 Se il 4 x i f N ml E N N f F N f x VA f N ee N i Fi NS Pai lt N if gt a a N f F N N Let x na Ni i i GN F a N N f ST N KS t Pai P Ni LU N 00 al N NIE a had DIA a N Y Pal i f ST N KN dEr mr n iy we ee SA I e a e NI N 4 mo N i x 4 4 i p KA 4 n 4 k w 4 e VI 4 ha Mu eee SUI Thermistor NTC Thermistor 2 wires 30000 25 C SISGEO Vibrating Wire Vibrating Wire 2 wires SISGEO a Page 56 of 68 Vibrating Wire with Thermistor Vibrating Wire with Thermistor 4 wires CH 1 4 J COIL THERMISTOR 30000 25 C Ratiometric 6 wire Ratiometric 6 wire External Power Supply Sensing o ONLY forEXT POWER SUPPLY Do not connect with ext power supply PWR GND PWR NOTE for this measure type two channels Ch1 Ch2 Ch
19. al Up Connection Properties General Options Security Networking Sharing Connect using All devices call the same numbers _ Dial only first available device Phone number Area code Phone number 00000 Altemates Country region code Use dialing rules Dialing Rules privacy statement Cc Rev 2 26 gt 5 A 1 N 7IZ0I4 connection just created and select View In the new windows select the modem used for miniOMNIAlog Dial up Connection and press on In the new window check if Enable hardware flow control is not checked After that click on OK button Modem Configuration Standard 56000 bps Modem 3 COM10 Maximum speed bps 115200 kd Modem protocol Hardware features atea ete roi sleet HO DEE r sees tete le stalen L Enable modem error control _ Enable modem compression Enable modem speaker Reselect the miniOMNIAlog Dial Up Connection and Click Connect The remote connection screen will be displayed Ke Connect miniOMNIA Dial up Connection ome Password _ Save this user name and password for the following users Me only B Anyone who uses this computer Dial 3333333333333333 Cancel Properties Helo Enter Username and Password set on miniOMNIAlog web pages by default Username User password blank Enter 0000 in Dial filed If the entered data are correct within a few seconds the communication will be established
20. are version is displayed like the string F X X X X X X only once After that the menu goes back to main menu USB connection Menu 8 If you press Enter key in correspondence to the menu entry Usb connection 8 the miniOMNIAlog will show the letter A and then the flashing number 0 to indicate to the user that PC connection can be started time for connection is 30 sec and after that the miniOMNIAlog goes back to main menu As connection is on the flashing number 0 becomes permanent The user can now use the miniOMNIAlog by PC NOTE As the user removes the miniOMNIAlog from PC so he removes remote PC connection the display goes back to connection state flashing 0 for 40 sec and during this time the user could reconnect After 40 sec it goes back to main menu Power off Menu 9 an Pressing Enter key in Power off 9 menu the miniOMNIAlog shows the character Now it is possible to remove the power supply internal batteries or external power supply NOTE the miniOMNIAlog could be powered off only if it is in STOP mode see Stop Menu 6 section in this manual Test signal modem Menu A Pressing Enter key in Test signal modem menu entry A the miniOMNIAlog shows a blinking A and after it displays a number from 0 to 3 This value indicates the quality of signal 0 No signal Bad signal 1 Low signal 2 Go
21. ation 760 grams batteries included 151 x 12E x A0 mm iwithout cable gland and antenna Polycarbonate Spring cage PCB termination blocks i clamps solid and stranded conductors up to 0 5 mm 20 AVVGI Recommended avery 2 years Wo reserva the right to chango oer product without prior noioa NeV Z Antenna Extemal power supply S485 instruments Analogue instruments Digital output KNIEEN ASSISTANCE After sales assistance for calibrations maintenance and repairs is performed by SISGEO s Service Department The authorization of shipment shall be activated by RMA Return Manufacturer Authorization Fill in the RMA module clicking on http www sisgeo com en assistance repairs Send back the instrument equipment with their complete accessories using suitable packaging or even better the original ones The shipping costs shall be covered by the sender Please return to the following address with suitable delivery document SISGEO S r l Via F Serpero 4 F1 20060 MASATE MI On the delivery document is mandatory to indicate the RMA code received Technical assistance e mail assistance sisgeo com APPENDIX A SISGEO R amp TTE Declaration of Conformity DoC The Manufacturer sisceosd OO Via Serpero 4 F1 20060 Masate Milano Italy hereby declare under our sole responsibility that the product minIOMNTAK Trade name Rr SISGEO Relevant supplementary Not applicable in
22. below All modems can communicate with miniOMNIAlog After the setup of the modem connected to the PC next step is to setup the remote connection on PC in order to connect it to miniOMNIAlog To setup this connection proceed as follows Open Control Panel Select Network and Sharing Center E All Control Panel Items SI 1 f Control Panel All Control Panel Items vG Search Control Panel pP Adjust your computer s settings View by Small icons v Pe Action Center 88 Add features to Windows 8 iv Administrative Tools ng AutoPlay Dy BitLocker Drive Encryption Eil Color Management E Credential Manager 7 Date and Time ng Default Programs gen Device Manager B Devices and Printers ER Display Ease of Access Center Family Safety File History _ Firebird Server Manager 32 bit Flash Player 32 bit E Folder Options da Fonts IR Grafica e multimedia Intel R WJ HomeGroup dk Indexing Options Internet Options 49 Java 2 Keyboard E Location Settings P Mouse Network and Sharing Center Notification Area Icons MR Performance Information and Tools Personalization US Phone and Modem B Posta elettronica 32 bit gt Power Options el Programs and Features Recovery 9 Region RemoteApp and Desktop Connections Sound amp Speech Recognition ts Storage Spaces Sync Center pd System ZL Taskbar sd Troubleshooting 88 User Accounts Id Windows 7 File Recovery B Windows Defender m Windows Firewall ES Windows M
23. eaker volume Maximum Port Speed 115200 gan Verify that the speed set is 115200 and that the option Wait for dial tome before dialing is unflagged ll Select Advanced and click on Change Default Preferences Standard 56000 bps Modem Properties General Modem Diagnostics Driver Details Events Extra Settings Extra initialization commands Initialization commands may lead to the exposure of sensitive information in the modem log Consult your modems instruction manual for more details canes Go to General and check that the port speed is 115200 and Flow Control is None default should be Hardware Standard 56000 bps Modem Default P Call preferences Disconnect a call if idle for more than Cancel the call if not connected within 60 SECS Data Connection Preferences Port speed 112200 kA Data Protocal Compression Bow control Canes Now select Advanced and check that the settings are the same as the picture below Standard 56000 bps Modem Default P General vanced Hardware Settings Data bits g ha Party None h Stop bits 1 ha Once ended click OK on each open screen to confirm the changes The Microsoft Windows modem setup has now ended DIAL UP CONNECTION CONFIGURATION NOTE You do not need to create a new dial up connection for each miniOMNIAlog Once you created one dial up connection you can add all modems using the properties shown
24. ect PC from miniOMNIAlog To disconnect the PC from miniOMNIAlog follows this steps on miniOMNIAlog web page press Logout button on Microsoft Windows select the Network icon on the application bar a 14 10 Networks menu will open Networks Airplane mode Off Connections Dial up Connection minjtOMNiAleg Dial Up Connect Disconnect Press on Disconnect button to close the Dial Up connection between PC and miniOMNIAlog NOTE when the USB cable is unplugged the miniOMNIAlog is rebooted This is necessary to switch from the USB power supply to the miniOMNIAlog power supply internal batteries or external power supply Unplug USB cable without any disconnection procedure If you unplug the USB cable without following the correct disconnection procedure the miniOMNIAlog is rebooted Under Data Monitor Events a Power Fail log appears Rev 2 26 02 2014 Page 46 of 68 2G GSM GPRS Modem SIM card If the miniOMNIAlog has an internal 2G GSM GPRS modem a SIM with APN for internet connection is needed The SIM selected must be enabled to internet traffic to send e mails and files on FTP Server for further details call your ISP Internet Service Provider Watch the following images to insert the SIM correctly NOTE remove the power supply before proceeding Insert the SIM card in the SIM slot NOTE pay attention to insert the SIM Card in the right side
25. ess Enter key in correspondence to the menu entry Start miniOMNIAlog 5 the miniOMNIAlog will start acquisitions Letter A is displayed if the miniOMNIAlog is successfully started if an error has occurred the system will go to error state and an error code will be shown After starting result is shown a 15 sec timeout is started After that the miniOMNIAlog will come back to main menu and will start the timeout display At timeout display expiration the display will turn off While the menu shows the start state error code or OK Select key causes the display returning back to main menu and timeout reset display Stop Menu 6 If you press Enter key in correspondence to the menu entry Stop miniOMNIAlog 6 the miniOMNIAlog will stop acquisitions Number 8 followed by letter A are displayed if the operation is successful if an error has occurred the system will go to error state and an error code will be shown After stop result is shown a 15 sec timeout is started After that the miniOMNIAlog will come back to main menu and will start the timeout display At timeout display expiration the display will turn off While the menu shows the stop state error code or OK Select key causes the display returning back to main menu and timeout reset display Firmware version Menu 7 If you press Enter key in correspondence to the menu entry Firmware Version 7 the miniOMNIAlog will show the installed firmware version Firmw
26. for every reasons the battery capacity descends under 50 consider its immediate substitution Periodically verify the voltage of batteries in batteries holder in case of a value inferior to 8 4V consider the substitution of the battery and check on the causes Avoid any activity that can put the battery poles in short circuit The use of non original SISGEO spare parts can cause abnormal functioning and dangers for people and things Supplied equipments and devices are not suitable to be installed in potentially dangerous areas or in areas where the use of explosion proof components is prescribed In potentially explosive areas it is necessary to shut down miniOMNIAlog Possible sparks could cause explosions or fires Causing serious injuries or even death Generally areas with a potentially explosive atmospehere are signalled Consider the periodic substitution of bags of hygroscopic salts miniOMNIiAlog contains fragile parts and components Do not drop disassemble press or deform miniOMNIAlog Do not use miniOMNIAlog if it is damaged The lack of respect for this behavior could damage the installed equipment DISPOSAL The disused devices has to be disposed of in accordance with the European directive 2002 96 CE Recycable materials contained in the device will be recuperated to avoid the environmental degradation For further information adress to the local disposal authorithy or to device seller g
27. formation to which this declaration relates is in conformity with the essential requirements and other relevant requirements of the R amp TTE Directive 1999 5 EC The product is in conformity with the following standards and or other normative documents HEALTH amp SAFETY Art 3f1 fa EN 61010 1 2010 EN 62311 2008 EMC Art 3f1 b EN 301489 1 V 1 9 2 EN 301489 7 V 1 3 1 SPECTRUM Art 3 2 EN 301511 V 9 0 2 OTHER Art 3 3 and voluntary Not applicable specs Limitation of validity if any Not applicable Supplementary information NEMEO 0470 Place and date of issue of this Doc MASATE MI November 27 2013 Signed by Mame in print ROMANO LAMPERTI Tide MANAGING DIRECTOR SISGEO S rl Via F Serpero 4F 20060 MASATE Tel 45 00 95 764 3 Fax 400 0576201 1 E madintoisisgen com hitp erww sisge0 com 4 f nnt DA Rev 2 26 02 2014 Page 68 of 68 Pa
28. g default setting OON DU Now it is possible to surf the configuration pages MINIOMNIA og LOCAL CONNECTION To establish a connection through Dial up call with a PC follow the next steps 1 Setup of a Modem on Microsoft Windows in this manual Microsoft Windows 8 2 Creation of a remote connection on Microsoft Windows 3 miniOMNIAlog setup To communicate with miniOMNIAlog by USB connection a small driver FTDI Driver is needed to permit to the PC to recognize the miniOMNIAlog Usually if your PC is already connected to the internet when you connect miniOMNIAlog Microsoft Windows is able to download and install this driver automatically If Microsoft Windows does not install the driver automatically or your PC is not connected to the internet you can download the driver for free at the following link http www ftdichip com Drivers VCP htm You have to do this operation only one time for each PC utilized with miniOMNIAlog After that every time a new miniOMNIAlog is connected to these PCs it will be automatically recognized because the driver is already installed on your PC SISGEO suggests to check periodically the new releases of driver at the previous link MICROSOFT WINDOWS MODEM CONFIGURATION E To setup a modem on Microsoft Windows follow the following steps NOTE for each miniOMNIAlog connected to the same PC Windows will create a new virtual COM port For this reason it is necessary
29. hange settings which depend on hardware system User gt this user can only view and download data Web interface language setup To modify the web interface language connect miniOMNIAlog and access to web interface with the user Admin or User that needs to change the language Then Select from left menu Advanced and in the submenus User Management In the page it will be displayed select Language Insert the password in the field Old password Press on Save changes Now the web interface will be converted in the selected language To convert also the left menu it is necessary to refresh the web page pressing F5 or the specific symbol on the internet browser address bar NOTE To avoid the conservation of the old language it is necessary to completely delete the internet browser cache WIRING SCHEMES Local analog sensor The Instruments measure type that can be read with miniOMNIAlog are Voltage _4 20mA Current Loop 2 wires _4 20mA Transmitter 3 4 wires Thermistor NTC Vibrating Wire Vibrating Wire with Thermistor Ratiometric 2 channels needed On the miniOMNIAlog electronic board there are four analog channels Each channel has four clamps for the instrument signals A B C D and one channel for the instruments shield _L Channels E Terminal Board Digitalized sensor miniOMNIAlog can read also the SISGEO digitalized RS 485 MODBUS instruments like In Place Inclinometers and Tiltme
30. ig mode Stop miniOMNIAlog is stopped No acquisition is in progress In this mode it is possible to download logs but it is not possible to change the configuration NOTE the humidity value shows N C because miniOMNIAlog hasn t a humidity sensor on board CONFIGURATION ACQUISITIONS in this page it is possible to set acquisitions frequency CHANNELS CONFIGURATION LOCALS in this page it is possible to set local analog channels on miniOMNIAlog ATTENTION For sensors wiring it is necessary to refer to the schemes on miniOMNIAlog web pages or to the par Connection Schematics at the end of this manual CHANNELS CONFIGURATION DIGITALS In this page it is possible to set digital channels to allow miniOMNIAlog to read digital instruments Until now SISGEO digitalized inclinometers and Tiltmeter RS 485 communication interface and MODBUS RTU communication protocol have been implemented For further information refer to the digitized sensors manual DATA MONITOR MEASURE In this page it is possible to display last miniOMNIAlog acquisition cycle It is also possible to download miniOMNIAlog executed and saved acquisitions NOTE the speed of refresh of the web page may not be sufficient to see the readings changes in real time TYPE OF USERS Users type in miniOMNIAlog system are Admin this user CANNOT change analog channels it can change for example acquisition frequency or change the polynomial This user cannot c
31. ity to temperature compared to other chemical systems The recommended operating temperature range is 40 C to 60 C 40 F to 140 F As with all battery systems service life is reduced as the discharge temperature is lowered below room temperature Batteries generate power through chemical reactions and these typically run much more slowly at lower temperatures However even at 40 C LiFeS2 batteries perform well at the rating drain 200mA LiFeS2 batteries can deliver approximately full rated capacity at 40 C if they are discharged at 25mA Thus at these rates batteries give comparable performances over the entire 100 C operating range lt 250 mA 1000 mA 25 mA Page 11 of 68 00 Co U O N ep DO Q ee gt beeren SAREMO Internal Batteries substitution warning Insert batteries in the batteries holder making sure of the correspondence between the polarities of battery and those of batteries holder Batteries that are inserted incorrectly could create a short circuit Do not recharge non rechargeable batteries Do not mix used batteries with the new ones or with batteries of different brand model Expired batteries have to be removed immediately from the batteries holder and correctly disposed of according to what was established by local rules if batteries are left in the batteries holder some
32. le in temperature VW sensors are read using an algorithm based on Fast Fourier Transform a parameter logged together with the reading shows the quality of the readings Readings are stored into the internal memory and can be downloaded using a USB pen drive or a laptop PC If the mini OMNIAlog is equipped with the GPRS module readings can be automatically transmitted to the user FTP folder or by email No software needs to be installed you simply connect the PC to the USB port and establish a dial up PPP connection Using an internet browser the user could configure the miniOMNIAlog and download data the miniOMNIAlog is fully configurable for each channel it is possible to set the acquisition time the conversion parameters and the alarm method SMS email digital output frequency increasing It is possible to update the firmware web pages using the USB pen drive miniOMNIAlog does not support a Dial UP M2M remote communication NOTE Power supply type internal batteries or external power supply the measure type of each analog channel current voltage NTC Wheatstone bridge vibrating wire and the present of the GPRS module are configured at factory The user is not authorized to modify these settings miniOMNIAlog default setting miniOMNIAlog utilizes the following IP address for USB connection with the PC IP Address 192 168 125 1 NOTE this IP address cannot be changed by the user because it is configured at factory
33. levels code scheme Battery level Display Code Description Low En Battery under 30 Medium Battery 50 High Battery 100 LOW charge MEDIUM charge HIGH charge The user can read the miniOMNIAlog state when he enters the menu As soon as the user enters the battery state a 15 sec timeout starts After that the miniOMNIAlog will come back to main menu and will start the timeout display it can be set up from the internet At timeout display expiration the display will turn off While the menu shows the display state Select key causes the display returning back to main menu and timeout reset display NOTE if the miniOMNIAlog has an external power supply battery state will L or not important in case of external power supply Firmware updating menu 3 NOTE miniOMNIAlog should be in Stop or Config state before using this function If you press Enter key in correspondence to the menu entry Firmware updating 3 the miniOMNIAlog will run the web and firmware updating from USB flash drive This menu is different from the others as updating needs a restart and systems management that are different from standard operations fr N Flashing 8 letter is shown on display during files copy At the end of files copy the miniOMNIAlog 1 shows error if USB flash drive was not found and waits for timeout display
34. lhde Lita 571 nomina voltage LEM min 2 A continous current discharge min 2 A pulse capability min 3 Ah capacity d months weth acquisition every 1 hour with nod instruments 24V DC OIZ mA 25 C 6 sec warm up data transmitted via F TFlemsd afer every acquisitton datalogger configured in Timed mode gt 6 months with acquisition every 1 hour with nod instruments 244 DC 12 mA 25 C 5 sec Warm upl deta transmitted via FTFlema once a day datalogger configured m Timed mode gt months wath acquisition every 7 hour with mod instruments 24Y DC 12 mA 75 C 6 sec Warm upl no dats transmission datalogger configured in Timed mode Seep moda Gij On 10 mA On with display on 40 mA Analog watisksaton 27 m Measurement 70 mA with 12 mA 24 V sensor consumption On with GPRS module 104 mA typically 350 m peak 30 10 60 C battenes 70 to 60 C 410 to 465 C batteries Uto 40 C IPG BO Il 2 lt MABA S000m Web server on board findapendent OS platform Live update ifinmvare and web pages FTP client to seni data alarms on a FTP server MAIL to sent data alarms to max 5 email address SMS to sent alarms to max 5 telephone numbers Data download readings logs in cow file compatible with Microsoft Excel Virtual channels management Languages Italian English and French Page 64 of 68 PHYSICAL CHARACTERISTICS VVeight Dimensions L x VW x HI Material Wirra Calibr
35. mimi OMNIA og User Manual Index PROVISIONS DISPOSAL IDENTIFICATION LABELS miniOMNIAlog OVERVIEW miniOMNIAlog default setting INSTALLATION PROCEDURE GROUND SYSTEM HOW TO OPEN miniOMNIAlog CASE miniOMNIAlog POWER SUPPLY Information about Internal Batteries Internal Batteries Substitution Warnings DISPLAY AND KEYBOARD FUNCTIONALITY State menu 1 Battery menu 2 Firmware update menu 3 SetUSB flash driver for miniOMNIAlog firmware update Data copy menu 4 Export file Measure and Measure log format Start menu 5 Stop menu 6 Firmware version menu 7 USB connection menu 8 Power off menu 9 Test signal modem menu A HOW CONNECT miniOMNIAlog TO PC miniOMNIAlog LOCAL CONNECTION 7 MICROSOFT WINDOWS MODEM CONFIGURATION 10 11 13 13 16 1 18 19 21 22 23 23 23 24 25 25 26 27 28 Microsoft Windows Modem parameters setup Dial Up connection configuration USB CONNECTIONBY USB ISOLATOR CABLE HOW TO DISCONNECT PC FROM miniOMNIAlog Unplug USB without any disconnection procedure 2G GSM GPRS MODEM SIM card Caution to be taken with 2G GSM GPRS modem APN configuration WEB PAGES FUNCTIONALITY Type of users Web interface language setup WIRING SCHEMES Local analog sensor Digitalized sensor Wiring RELAY OUTPUT VOLT FREE CLOSURE ANOMALIES and ALARM WARNINGS MAINTENANCE TROUBLESHOOTING TECHNICAL DATASHEET ASSISTANCE APPENDIX A 32 36 45 46
36. mperature drift Input noise voltage input imata sustained input voltage wo damage GO common mode rejection Homma mode rejectan Input impedence OUTPUT Charta output Rev 2 26 02 2014 High precision measurement low speed 5 SPST init analog luath suto calibrationi 15 5 sec instrument Warm Up depending on sensor configuration Measurement 3 sec Standard measurement 20 SPS iret analog with auto calibrationi 3 4 sec Instrument warm up depending on sensor comiguraton Measurement 0 9 sec Fast measurement high speed 40 SPS int anatog Ino auto calibretoni 11 sec instrument warm up depending on sensor configuration Measurement 0 5 sec Mote T mit analog phase is made only one Ume before ihe messurement cycle Mate the YW measurement could require more Ume 24 bit 22 true bit differentia Analog to Digital Converters SSPS 0 24 Average Function suto calbratson and auto range Current loop 2 wires range 0 25 mA Power supply 24V DE TA DC up ta 25 mA eternal Transmitter 3 4 wires range 0 25mA Power supply ZE OC 12V DC lup to 50 mA external Voltage 4 wires range 470m 100m 4 10V Power supply 24 DC TN DC BV DC lupo 50 mA external Wheatstone bridge 6 wires with sensing 7 channets used range Om Vi Mias bridge resistance 10 KO min bridge resistance 200 0 Power supply 5 DO up te 60 mA Thermistor NTC SEO range DISC to 150 0 Power supply DISMA 0 1m Vibrati
37. ng Wire range 400 to G000Hr7 Excstetion voltage range 2 TOV Sine waa 1 p at FS 20 mA 1 pv at FS 10 mv 10 pv at FS 100 mY 100 py at FS 21V 1mVat FS 2107 0 7 SC for NTC 01 Herat FS 6600 Hr DOO mv at FS 210 mA z 7 065 FS 1 FS for ATC with Standard Measmement lt TOppm C range 30 C to 70 C 5 4 ppp 60 DC mas gt 2606 gt 90d8 20 GO typical One relay output for alarm etc volt iree closure low voltage 304 LAI Page 63 of 68 PROTECTIONS SYSTEM POWER REQUIREMENTS Voltage External rechargeable battery Le solar panel system Interna non rechargeatle batteries no external power supply Operating time with interral batteries Tygecal current dram 2 W ENVIROMENTAL CONDITIONS Operating temperature Storage temperature Protection Humidity Ovarvoltage category Pollution degres Sound levels Maximum height of usa SOFTWARE amp HRMWARE Rev 2 26 02 2014 Electro mechanics rays for each measunng channel Electrical endurance min 25 10 operations Mechanical endurance 100x108 operations Cramm protection Ges Discharge Tubes CHD Breakdown Voltage 10045 DO tolerance of DCOBV 7056 impuse Breakdown Voltage 100wus 250 impubes Breakdon Voltage iT betas i S00 Owervoltage and reverse polanty protection Short circuit protechon on every outputs Fito 14V DC ireverse polarity protected max 12 W TEV DC nomaal 6 batteries size AA chemistry Lithium iron desu
38. obility Center EP Windows Update Select Set up a new connection or network Mi Network and Sharing Center RE S ControlPanel All Control Panel items Network and Sharing Center vG Search Control Panel P View your basic network information and set up connections Control Panel Home View your active networks Change adapter settings Change advanced sharing WPSWireless_Display 2 Access type Internet settings Public network Connections W Wi Fi WPSWireless_Display Change your networking settings ee Set up a new connection or network a Set up a broadband dial up or VPN connection or set up a router dr access point Troubleshoot problems Diagnose and repair network problems or get troubleshooting information See also HomeGroup Internet Options Windows Firewall In the new screen select Connect to the Internet and click Next um Set Up a Connection or Network Choose a connection option Connect to the Internet Set up a broadband or dial up connection to the Internet ug Set up a new network omg Set up a new router or access point Manually connect to a wireless network cag Connect to a hidden network or create a new wireless profile Do Connect to a workplace Set up a dial up or VPN connection to your workplace Rev 2 26 02 2014 Page 37 of 68 ee ee A Now select Set up a new connection anyway 3 Connect to the Internet You are already connected to the
39. od signal 3 Excellent If you select this function without the presence of the internal modem an error E7 appears on the display EE EE sal E7 ES NOTE miniOMNIAlog has to be in STOP or CONFIG mode before using this function Otherwise miniOMNIAlog shows error E3 How connect miniOMNIAlog to PC The miniOMNIAlog can be found in RUN mode stand by miniOMNIAlog timed waiting for an acquisition CONFIG mode STOP mode ERROR state Connect the PC trough the USB cable to the miniUSB port of miniOMNIAlog From this moment and as long as the USB cable is disconnected the power supply will be taken from the PC USB device uate La tagi x pe co TY u A4 LA MAMA 1 Select item 8 from display menu and click enter 2 Letter A will appear on display meaning that the mini OMNIAlog is correctly set up in STOP state 3 After that flashing number 0 will appear on display meaning that the miniOMNIAlog is waiting for a connection The miniOMNIAlog waits for connection for 30 sec After 30 sec you should repeat connection procedure from point 1 to start a connection 4 Start PC connection by clicking on connect button in the connection window see the par miniOMNIAlog local connection After connection number 0 will appear on display Open Browser and enter address 192 168 125 1 Enter miniOMNIAlog Username and Password see the par miniOMNIAlo
40. on Skip to skip the connection attempt once the dialing starts B Connect to the Internet Connecting to miniOMNIA Dial up Connection U Dialing 3333333333333333 Skip Cancel Click Close in the following screen Connect to the Internet The connection is ready for use You can find the new connection under Control Panel gt Network and Sharing Center gt Change w adapter settings r Network Connections 0 tT ry Control Panel Network and Internet Network Connections gt v Search Network Connections Organize v sv Ti gt Ethernet A miniOMNIA Dial up Connection a Talk2m eCatcher Connection Network cable unplugged Disconnected Network cable unplugged x A Realtek PCle GBE Family Controller A Standard 56000 bps Modem x BT TAP Winz2 Adapter V9 on Wi Fi WPSWireless_Display 2 iff Ralink RT3290 802 11bgn Wi Fi A 4 items 8 gt _Rev 2 26 02 2014 Page 40 of 68 Right click on miniOMNIAlog Dial up Connection and select Create shortcut Network Connections o 1 E Control Panel Network and Internet Network Connections v Search Network Connections Organize v Start this connection Rename this connection Delete this connection ii j Ethernet A GD MINIONNIA Dial up Commotina m Tat ee aL stenen Connecti A Network cable unplugged DN Disconnected Connect Disconnect ugged x A Realtek PCle GBE Family Controller f Standard 56000 bps f Stat
41. reserve batteries life during PC connection the power supply is automatically taken from the PC through USB cable connection In any case it is necessary to connect to a power supply NOTE the maximum current permitted on the mini USB connector is 500mA This current limitation must be taken into account when you are powering this device for example it is not possible to turn on the 2G GSM GPRS modem when the USB cable is connected to the PC SYSTEM POWER REQUIREMENTS Voltage 9 to 14 V DC reverse polarity protected max 12W External rechargeable battery i e from a little solar panel system 12V DC nominal In case of external power supply the external power source must be separated from the parts in dangerous voltage with a double insulation and must guarantee an insulation of at least 3000Vrms An external switch appropriately labeled has to be integrated into the plant for power disconnection The power cable used must have a section of at least 0 5mmq anda rating of 70 C Internal non rechargeable batteries no external power supply 6 batteries size AA chemistry Lithium Iron disulfide Life s2 nominal voltage 1 5 V min 2 A continuous current discharge min 2 A pulse capability min 3 Ah capacity P n SIT i if Pa he x i _ x kS j pe N a ri A Mia Y i ST _ x Pes n n Y n Information about Internal Batteries Lithium iron disulfide LiFeS2 batteries have a much lower sensitiv
42. sures events log alarms logs using an USB flash drive 3 PC through web interface 3 FTP or e mail A USB flash Drive After the copy using a USB flash drive a folder with the following format will be automatically created lt miniOMNIAlogname gt Log Within the folder there will be the following four csv files ALog dd mm yy csv in this file there are all the alarms detected from the miniOMNIAlog Elog dd mm yy csv in this file the events recorded from the miniOMNIAlog are saved Mlog dd mm yy csv in this file the measures in log format are saved There are also other information such as any alarm for the sensors the measurements unit the vibrating wire measurements parameters etc Mlog dd mm yy Column csv in this file the measures ordered in columns are saved This kind of display is suited for data management with spreadsheet In the file name dd is the day mm is the month and yy is the year B PE When you download data directly from the miniOMNIAlog web pages there is a specific field for each data file you can choose the destination folder on your PC and the file name if your Internet browser is well configured C FIP or e mail If you set the miniOMNIAlog to transmit the csv reading file only the one ordered in columns by e mail or by FTP the name of the file is the following mLog_dd _mm_yy__hh_mm csv In the file name hh is the hour mm is the minute Start Menu 5 If you pr
43. t miniOMNIAlog contains electronic components and batteries that have to be disposed of separately from domestic waste When this product reach its useful life it is necessary to bring it to a gathering place for the recycling of electronical components An uncorrected disposal on the part of the user could be subject to penalties IDENTIFICATION LABELS Every miniOMNIAlog datalogger from now on indicated simply as miniOMNIAlog or datalogger has two type of identification labels The first label placed on the upper side of miniOMNIAlog shows the registration Serial Number of the product It is important to communicate these data in case of request of information or accessories concerning the product The second label placed on the back side of miniOMNIAlog shows information about the electrical equipment of the product Respect the requirements written on the label The lack of respect for these requirements could damage the product or put in danger the operator rating 9V 12W max from internal NR AA 1 5V batteries 12V 12W max from dedicated AC DC power source IP grade IP67 CE A E 0470 miIniOMNIAlog OVERVIEW miniOMNIAlog is a 4 channel datalogger designed for low power consumption and easy installation it reads most analog current voltage NTC Wheathstone bridge vibrating wire and digital sensors Each channel is individually configured at factory Readings are accurate repeatable and stab
44. ters On the miniOMNIAlog board there is one clamp for the digitalized instruments connection Every clamp has 5 terminals 3 for communication RS 485 D D and GND 2 for the instruments power supply V OUT V and GND Digitalized Instruments Clamp ATTENTION The voltage V OUT V and GND is switched on and off from the software V OUT is the unregulated power supply input V IN V and V It is not possible to power the digitalized instruments when the USB connection is on RS 485 clamp has a resistance of 1200 the same resistance should be exposed at the end of 485 bus el Wiring Refer to the following image for the correct wiring of instruments analog and digitalized to the clamp You have to push the little button over the clamp insert the wire and release the button Following this scheme for each instruments measure type Voltage Voltage 4 wires SINGLE External Power Supply CH 1 4 CHA GND PWR ONLY for EXT POWER SUPPLY 8 PWR e Do not connect with ext power supply pi nd GND PWR x SISGEO Rev 2 26 02 2014 Page 54 of 68 Se x a r N a 4 pe x a N Pi an P y a Xx i adi fof a x j Pes i 8 TN N a ke A f 4 p N al N i gt NG pl iN N N t Pai hi f N ff N DEF lt lt ali N N i VA pe if ai N i N o et x if a N A x i VA e si a Ne PA
45. to repeat the following steps for each miniOMNIAlog Connect miniOMNIAlog to the PC through a USB cable A Virtual COM port is created Open Control Panel Settings Control Panel Rev 2 26 02 2014 Page 28 of 68 Select Phone and Modem All Control Panel Items T E t Control Panel All Control Panel lterns Adjust your computer s settings ng AutoPlay E Credential Manager EN Device Manager i Ease of Access Center _ Firebird Server Manager 32 bit my Fonts amp Indexing Options g Keyboard Mouse E Performance Information and Tools A Posta elettronica 32 bit Recovery ly Sound a Sync Center Troubleshooting B Windows Defender Windows Update Rev 2 26 02 2014 BM Add features to Windows 8 By BitLocker Drive Encryption Eh Devices and Printers Family Safety Flash Player 32 bit DI Grafica e multimedia Intel R Internet Options gt Language ni Network and Sharing Center E Personalization gt Power Options dd Region g Speech Recognition E System sa User Accounts gr Windows Firewall Select Modems in the screen Fhone and Modem ip Remove n En i A Le Click Add to add a new modem C Search Control Panel h View by Small icons 7 E Administrative Tools la Color Management Default Programs Display File History E Folder Options a HomeGroup E Java Location Settings Notification Area Icons i Programs and Features
46. us v3 A a less Diani Cancel as Default Connection WPSWireless_Display lt afl Ralink RT3290 802 11bgn Wi Fi A Create Copy A items 1 item selected Click Yes on the following screen It will create a shortcut on the desktop for this connection From now on you should click on this link to start the connection with miniOMNIAlog through USB connection r Shortcut Ww Te i i Windows can t create a shortcut here miniOMNIAIS SSS Do you want the shortcut to be placed on the desktop instead tal up Gonnection Ne Shortcut _Rev 2 26 02 2014 Page 41 of 68 Double click on this icon It will open a screen with the available connections Click on the remote i connection just created e g miniOMNIAlog Dial up Connection NY Networks Airplane mode Off E Connections miniOMNIA Dial up Connection WI FI WPSWireless_Disp Sisgeo Free Hotspot Alice 58221846 SISGEO WiFi Hidden network Rev 2 26 02 2014 Connected all ail alll alll ll Networks Airplane mode Off i Connections miniOMNIA Dial up Connection Wi Fi WPSWireless Disp Connected Sisgeo Free Hotspot Alice 58221846 SISGEO Wifi Hidden network Page 42 of 68 Only for the first connection right click on the remote connection properties Networks Airplane mode Off Connections View connection properties mintOMNIAlog Dial Up Connect Wi Fi Configure button E miniOMNIAlog Di
47. wer supply alarm thresholds miniOMNIAlog with external power supply Icon showed plug Display L High alarm threshold 14V Low alarm threshold 10 5V miniOMNIAlog with internal battery pack Icons showed cell battery Full battery voltage gt 9 6V Medium battery 8 4V lt voltage lt 9 6V Low battery Voltage lt 8 4V Display 3 lines Voltage gt 9 6V 2 lines 8 4V lt voltage lt 9 6V 1 line voltage lt 8 4V High alarm threshold not present Low alarm threshold 8 4V Maintenance Always disconnect miniOMNIAlog from its power source during maintenance REPAIR OR MODIFY miniOMNIAlog SISGEO doesn t allow the user to repair or modify miniOMNIAlog The lack of respect of this instruction could provoke damages that aren t covered by any warranty In case of malfunctioning contact the assistance SISGEO miniOMNIAlog cleanliness To clean miniOMNIAlog use a soft cloth without using any cleaning product CALIBRATION SISGEO suggests a periodic calibration of miniOMNIAlog every 2 years or when necessary Contact the Technical Assistance SISGEO to receive further information Troubleshooting Abnormal reading Verify the connections between instruments and clamps using the manual Use and Maintenance or clicking on the button Connection scheme on web server pages Verify with a portable datalogger i e New Leonardo or CRD 400 the correct functioning of the sensor Impossible to Make sure you
Download Pdf Manuals
Related Search
Related Contents
取扱説明書(1.9 MB) Trust Vivy Whirlpool LA5500XP User's Manual English only. Logiciel en anglais seulement. - Fisher CP20 Rev 2 User Manual AnaGate UP 2.0 Altronix ALTV2432300UL power extension Copyright © All rights reserved.
Failed to retrieve file