Home
User Manual - MidgeBusters
Contents
1. 1 Turn gas valve OFF 2 Wait 10 minutes to fully stopp and cool off 3 Remove hat 4 Remove clear plastic cowl 4 x philps screws 5 Gently clean using bottle brush dipped in soap water 6 Check and blow the air passages air inlet under fan and heatsink for fresh air in blockage A Clear plastic cowl B Fan blades Watch cleaning instruction video at www predatormosquitotraps com Before Each Use 1 Keep the Predator Dynamic area clean and free from any combustible materials gasoline and other flammable vapors and liquids 2 Do not obstruct the flow of the combustion of gas and the ventilation air 3 Keep the ventilation opening s of the gas tank area free and clear from debris 4 See Cleaning Instructions for proper cleaning instructions Cleaning Instructions Routine Service To ensure maximum performance and to lengthen the life of your Predator Dynamic device perform these steps each time your tank is empty This model will consume a standard 10 kg gas tank every 15 18 days Note While unit is in use check the following weekly e Check catch container and clean e Check air passages for blockage 10 Turn valve on gas tank OFF Disconnect hose regulator gas line from tank by turning knob counterclockwise Remove empty tank replace with full gas tank Remove catch container empty and clean Slide catch container back into place Remove used Rapid Action Sticky Pa
2. Lighting instructions oO om FR W PP End of Season Storage To lengthen the life of your Predator Dynamic device perform these simple steps at the end of the mosquito season 1 Turn valve on gas tank OFF 2 Disconnect regulator hose assembly from tank by turning knob counterclockwise 3 Remove tank cover 4 Remove gas tank and store outdoors away from children and must not be sto red in a building garage or other enclosed area 5 Remove and properly dispose of the Rapid Action Sticky Paper and Rapid Action attractant 6 Cover your Predator Dynamic device to protect from dust and store it in a cool dry place CAUTION Storage of an outdoor gas appliance indoors is only permissible if the tank is disconnected and removed from the outdoor gas appliance Limited Warranty Amplecta AB Vendor warrants to the original retail purchaser of this product and to no other person that if this product is assembled and operated in accor dance with the printed instructions accompanying it then for a period of one 1 year from the date of purchase all parts in such product shall be free from defects in material and workmanship Vendor may require reasonable proof of your date of purchase Therefore you should retain your sales slip or invoice This Limited Warranty shall be limited to the repair or replacement of parts which prove defective under normal use and service and which Vendor shall determine in its r
3. Table of content Te O E aeaea E AEREA EER 2 3 HOWIEWOKS aee aa A AEA A 3 PS SEMIDNY IMS WUCHONS veserissesecsssesocsocecocsenescesocssnetoosonesoi 4 8 Trap placement CUING crbiucscuccosmmesmencnenscnecesmenenennecnehebinhed 9 Operation NS rUC ONS ncr 10 VATE TAIN AAE EITA EEEE 10 11 POUPE OO E EAEE A EAA EAT 11 Fuel and Gas pressure specification esere 11 How it works The Predator Dynamic mimics a perspiring person with 6 cues to attract female mosquitoes e Breath CO moist and heat e Heat body skin temperature e Sweat Rapid Action Attractant e Movement Blinking LED light e Water trap Wet tray in collector e Light attracts 360 degrees using UV LED lights It catches the mosquitoes in two ways e Strong vacuum fan that sucks the insects in and dehydrates them to die e Rapid Action Sticky Paper Powerful glue Trap with contrast pattern Not all mosquitoes are attracted to basic Octenol We have therefore added an extra large multi attractant chamber under the hat Here you can fit all Rapid Action attractants as well as those of our competitors or your own whichever you prefer The Predator Dynamic will concentrate attracting scent of the attractant close the strong vacuum inlet where the mosquitoes are sucked in Rapid Action Octenol Blue Mosquito midge gnat biting flies Northern Europe northern US and Canada Rapid Action Fusion Octenol Green Mosquito midge gnat asian tiger mosqui
4. at valve e Spoon leak check solution at all x locations See page 5 illustration 3 e f any bubbles appear turn gas tank OFF reconnect and re test If you conti nue to see bubbles after several attempts disconnect gas source and contact your local gas supplier for assistance e f no bubbles appear after one minute turn tank OFF wipe away solution and proceed Placement CAUTION Tipping danger Use stakes to secure Once you have selected the location secure the Predator Dynamic device by pla cing a stake in each of the 2 front feet Maximum performance may require relocating your Predator Dynamic device from time to time To move remove stakes place your foot on the cart base and tilt backward by holding the handle Pull to the new location Re install stakes Turning Off Turn gas tank OFF by turning valve clockwise until it stops CAUTION The gas supply must be turned off at the gas tank when this outdoor gas appliance is not in use Cleaning and Care CAUTION All cleaning and maintenance should be done when Predator Dynamic is cool and with the fuel supply disconnected CAUTION DO NOT clean any Predator Dynamic part in a self cleaning oven CAUTION This Predator Dynamic should be thoroughly cleaned and inspected on a regular basis CAUTION Abrasive cleaners will damage this product CAUTION Always make sure vaccuum fan blades spin freely CO engine will get distroyed if not taken care of
5. redator Dynamic rr PREDATOR User Manual Congratulations on your new Predator Dynamic the latest in effective mosquito extermination systems incorporating decades of research and development The predator Dynamic is probably the most powerful trap in the the majority of mosquitoes species The Predator Dynamic is adjus market today It has been developed to attract female mosquitoes table in height It can go low to attract the fast and low flying Aedes in large areas and will make sure mosquito colonies in your vicinity Asian Tiger Mosquito in mid position it is tuned for Culex most will deteriorate and in many cases be extinguished altogether common mosquitoes At its highest position it is in perfect altitude Our goal was to create a dynamic multi platform that can attract for most Midges and Gnats Visit www predatormosquitotraps com for instructional videos and support Predator Dynamic Precautions DANGER If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance immediately and call your gas supplier or your fire department WARNING FOR YOUR SAFETY 1 Do not store or use gasoline or other flammable liquids or vapors in the vici nity of this or any other appliance 2 Agas cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER Failure to follow the dangers warning and cau
6. 5 minutes before attempting to restart the engine by following the lighting instructions Assembly instructions Predator Dynamic eee Put cylinder cover onto gas tank we PREDATOR J C i j Y Attach the Rapid Action Sticky Paper Connect paper ends and slide on CO engine Remove surface protection PIREDWAWOUR Predator Dynamic Assembly instructions Place the attractant Remove the seal from the Rapid Action attractant and place it into the multi attractant compartment A Predator Dynamic is also compatible with the attractant Lurex Turn the hat onto the engine Fill up your water trap Fill the tray with water without chloride and 2 teaspoons of sugar and one 1 drop of liquid soap make sure it is without added scent to break the water surface tension This mix generally produces better catches rates than the dry catch collector This is because the airflow from the trap is enriched with humidity much like human breath and also contains scents of sugar which to mosquitoes is as a source of energy Carefully attach the water filled catch collector Slide the catch collector into 3 hooks underneath the engine Make sure to
7. or explosion hazard when testing for a leak a Always perform leak test before lighting the Predator Dynamic and each time the tank is connected for use b No smoking Do not use or permit sources of ignition in the area while con ducting a leak test c Conduct the leak test outdoors in a well ventilated area d Do not use matches lighters or a flame to check for leaks e Do not use Predator Dynamic until any and all leaks are corrected If you are unable to stop a leak disconnect the gas supply Call a gas appliance service man or your local gas supplier Do not store or use gasoline or other flammable liquids or vapors within 8 meters 25 feet of this appliance 1 P 1 on from combustible materials gasoline and other flammable vapors and liquids 16 Minimum clearance from sides and back of unit to combustible construction oO Do not use in an explosive atmosphere Keep Predator Dynamic area clear and free 50 centimeters 21 inches from side and 50 centimeters 21 inches from back Do not use this appliance under overhead combustible surfaces 1 N circulating air passages clean Inspect Predator Dynamic before each use 18 Do not alter Predator Dynamic in any manner 19 Do not use the Predator Dynamic unless it is COMPLETELY assembled and all parts are securely fastened and tightened 2 It is essential to keep the Predator Dynamic s valve compartment burners and This Pre
8. and kill mosquitoes This product is not capable of e Completely eliminating mosquito populations e Eliminating the possibility of disease from mosquitoes e For best results keep your Predator Dynamic running continuously and replace the propane cylinder as soon as it is empty Begin operating your Predator Dynamic device once low temperatures remain above 10 C 50 F To reduce and maintain mosquito populations it is important for your Predator Dynamic device to operate continuously Do not turn off the gas tank valve until your Predator Dynamic turns off then immediately replace the empty tank with a full tank of propane e Always contact our experts before returning product to place of purchase Important Information about the attractant Your Predator Dynamic device includes an attractant that contains octenol 1 octen 3 ol This non toxic pesticide is an effective attractant supplement for some mosquito species KEEP OUT OF REACH OF CHILDREN CAUTION Harmful if swallowed absorbed through the skin or inhaled Avoid con tact with skin eyes and mouth Wash hands thoroughly with soap and water after handling Important Information about ultraviolet light This device radiates intense ultraviolet UV light when operated CAUTION Do not look directly at the device during operation Exposure to UV light even for a brief period can damage your eyes Always contact our experts before returning product to place of purchase
9. 5 2 LPG 35 3 Fuel and Gas pressure specification Troubleshooting Problem Possible Cause Prevention Cure Engine will not light Igniter does not work Check battery or engine stop Replace if necessary No Gas Check gas tank valve is open and tank not empty Replace if necessary Clogged gas filter Clean gas filter in the end of hose of regulator if necessary Check and clean air inlet and air passages for fresh air blockage Clogged air inlet Does not start with full Tank overfilled too Disconnect gas tank new replacment gas much pressure Open valve and release tank gas for 10 seconds Wait for the pressure valve on the unit to reset 3 minu tes Reconnect gas tank and try again maximum 3 times Hold in red and blue control knobs for 30 seconds If it still does not light contact your local provider If still not working Low gas quality Abnormal noise Fan clogged by insects Trap engine will get damaged if not cleaned immidietaly See Clea ning and Care page 10 Visit www predatormosquitotraps com for more information and support Model No LPG35 1 LPG35 2 LPG35 3 Heat input 0 3kW 21 24g h Gas category 134 28 30 37 l3B P 50 l3B P 30 Type of gas Butane at 28 30 mbar LPG gas mixture LPG gas mixture Propane at 37 mbar at 50 mbar at 28 30 mbar Pressure 28 30 37 mbar 50mbar 28 30 mbar Destination BE FR IT LU I
10. E GB AT DE CH SK LU NL DK FI countries GR PT ES CY CZ LT SE CY CZ EE SK CH SI LT MT SK SI BG IS NO TR HR HU RO IT Injector size 0 30 mm 0 26 mm 0 30 mm Gas regulator Certified regulator according to EN 12864 flow rate max 2kg h Gas hose Certified gas hose according to applicable EN standard 100 cm ll International patents application filed but not published Applications no PCT SE2010 050363 PCT EP2010 054366 PREDATOR AMAD AMPLECTA Targeted Mosquito Traps BioTech www predatormosquitotraps com www rapidactionbiotech com www amplecta com Predator Dyanmic by Amplecta AB Sweden info amplecta com
11. ITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE VENDOR SHALL NO LIABILITY TO PURCHA SER OR ANY THIRD PARTY FOR ANY SPECIAL INDIRECT PUNITIVE INCIDENTAL OR CONSEQUENTIAL DAMAGES Vendor further disclaims any implied or express warranty of and assumes no responsibility for defects in workmanship caused by third parties This Limited Warranty gives the purchaser specific legal rights a purchaser may have other rights depending upon where he or she lives Some jurisdictions do not allow the exclusion or limitation of special incidental or consequential damages or limitations on how long a warranty lasts so the above exclusion and limitations may not apply to everyone Vendor does not authorize any person or company to assume for it any other obligation orliability in connection with the sale installation use removal return or replacement of its equipment and no such representations are binding on Vendor If problems can not be correct by using these methods please visit www predatormosquitotraps com or contact your local provider The use and installation of this product must conform to local codes Manufactured by Amplecta AB Gotaforsliden 13 SE 431 34 Molndal Sweden www amplecta com Made in P R C 2010 Amplecta AB All Rights Reserved Predator Dynamic Rapid Action Sticky Paper and Rapid Action Attractants are trademarks of Amplecta AB Sweden LPG 35 1 LPG 3
12. any gas product Gas is explosive under pressure heavier than air and settles and pools in low areas Gas in its natural state has no odor For your safety an odorant is added that smells like rotten cabbage Contact with gas can cause freeze burns to skin Gas tank needed to operate Only tanks marked LPG Butane and Propane gas are suitable for this unit The gas supply tank must be constructed and marked in accordance with the Specifications for gas Cylinders in your country In the U S Department of Transportation DOT or the National Standard of Canada CAN CSA B3339 Cylinders Spheres and Tubes for the Transportation of Dangerous Goods and Commission Gas tank must be arranged for vapor withdrawal The gas tank must have a listed overfilling prevention device OPD Only use cylinders equipped with a cylinder connection device compatible with the connection for outdoor cooking appliances The gas tank must have a tank collar to protect the tank valve Never use an gas tank with a damaged body valve collar or footing Dented or rusted gas tanks may be hazardous and should be checked by your gas supplier prior to use The gas tank should not be dropped or handled roughly Tanks must be stored outdoors out of the reach of children and must not be stored in a building garage or any other enclosed area Your tank must never be stored where temperatures can reach over 60 C 125 F Never keep a filled gas tank in a hot car
13. dator Dynamic should be thoroughly cleaned and inspected on a regu lar basis Clean and inspect the hose before each use of the appliance If there is evidence of abrasion wear cuts or leaks the hose must be replaced prior to the appliance being put into operation 2 and hose assembly shall be that specified by the manufacturer Use only the regulator and hose assembly provided The replacement regulator 22 Use only Amplecta Predator Dynamic factory authorized parts The use of any part that is not factory authorized can be dangerous This will also void your warranty Precautions Table of content Predator Dynamic 23 Do not use this appliance without reading Operating Instructions in this manual 24 Do not install or use in or on boats or recreational vehicles 25 Product performance can vary due to weather wind and other environmental conditions 26 Never lean over the Predator Dynamic when lighting 27 Do not attempt to move Predator Dynamic when in use Allow the Predator Dynamic to cool before moving or storing 28 Storage of Predator Dynamic indoors is permissible only if the tank is discon nected removed from the Predator Dynamic and properly stored outdoors 29 Do not attempt to disconnect the gas regulator from the tank or any gas fitting while the Predator Dynamic is in use 30 Do not use Predator Dynamic for indoor cooking or heating TOXIC fumes can accumulate and cause asphyxiat
14. easonable discretion upon examination to be defective Before returning any parts you should contact Vendor s Customer Service Department using the contact information listed below If Vendor confirms after examination a defect covered by this Limited Warranty in any returned part and if Vendor approves the claim Vendor will replace such defective part without charge If you return defective parts transportation charges must be prepaid by you Vendor will return replacement parts to the original retail purchaser freight or postage prepaid Warranty Trouble shooting Pressure specification Predator Dynamic This Limited Warranty does not cover any failures or operating difficulties due to accident abuse misuse alteration misapplication improper installation or impro per maintenance or service by you or any third party or failure to perform normal and routine maintenance on the product as set out in this owner s manual In addi tion the Limited Warranty does not cover damage to the finish such as scratches dents discoloration rust or other weather damage after purchase This Limited Warranty is in lieu of all other express warranties Vendor disclaims all warranties for products that are purchased from sellers other than authorized retailers or distributors including the warranty of merchantability or the warranty of fitness for a particular purpose VENDOR ALSO DISCLAIMS AND ANY ALL IMPLIED WARRANTIES INCLUDING W
15. int See Checking for Leaks page 10 Predator Dynamic Assembly instructions Insert the gas cylinder into the base and tighten the safety lock WARNING Change the gas cylinder in a well ventilated area away from any ignition source candle cigarettes or open flame Do not obstruct the ventilation holes of the cylinder enclosure Use only the type of gas and the type of cylinder specified by the manufacturer Insert the battery into it s chamber Open battery compartment by turning cap located underneath CO engine counter clockwise 6 Igniter Button Control Valve Button ae Bee Start the engine Open gas tank valve COUNTER CLOCKWISE fully Turn back a quarter of a turn CLOCKWISE 1 Press and hold black control valve button 2 IMMEDIATELY press and hold the red igniter button down until you hear a POP sound indicating ignition Normally occurs within 20 seconds 3 Continue to hold black control valve button for 30 seconds 4 The needle on the engine gauge should begin to move into the Green zone Within minutes LED lights will be flickering and the vacuum fan will be running with air flow out of the engine bottom indicating the Predator Dynamic is ready to operate CAUTION If engine fails to light shut gas off at tank and wait
16. ion After a period of storage and or nonuse check for leaks burner obstructions and inspect for any abrasion wear cuts to the hose 32 If Predator Dynamic is not in use the gas must be turned off at the supply tank 33 Keep air intake areas clear of dust dirt and debris 34 Do not allow children to operate or play near a Predator Dynamic device when it is in use Inspect for damage and wear during each maintenance cycle at least once per month and each time the cylinder changed It is recommended to use only Rapid Action mosquito attractant in your Predator Dynamic The use of other attractants has not been tested with your product and void your warranty Maximum inlet gas supply pressure See Fuel and Gas pressure specification for your country on page 11 Deaths serious injury or damage to property may occur if the above is not fol lowed exactly 3 3 on 3 o gt 3 Q 3 oo Please retain user s manual for future reference If you are assembling this unit for someone else give this manual to him or her to read and save for future reference Important Information Your Predator Dynamic device operates 24 hours a day to help reduce the nuisance of mosquitoes It attracts female mosquitoes that are seeking a blood meal to nou rish their eggs By removing these females you also remove their eggs This Product will provide the following results when used as directed e Attract trap
17. keep it in the same location for the rest of the season It will break down the mosquito colony over time Most common mistakes are to put he trap in a windy place try to find a calm location Avoid direct sunlight as it will dry out the lures and mosquitoes do not like to fly in the sun Visit our web page www predatormosquiotraps com for more information tips blogs and videos Here you can also buy accessories spare parts and user manuals We wish you every success with your new Predator Dynamic mosquito trap and hope you will enjoy less mosquitoes and more outdoor fun for years to come Predator Dynamic Assembly instructions For Easiest Assembly e To avoid losing any small components or hardware assemble your product on a hard level surface that does not have cracks or openings e Clear an area large enough to layout all components and hardware e When applicable tighten all hardware connections by hand first Once the step is completed go back and fully tighten all hardware e Follow all steps in order to properly assemble your product To complete assem bly you will need e 1 Leak Detection Solution Instructio
18. ns on how to make solution are included in Operating Instructions section e 1 precision filled standard grill gas tank with external valve threads Note You must follow all steps to properly assemble your Predator Dynamic Typical assembly approximately 30 minutes A Hat B Rapid Action Attractant remove sealing before use C Multi attractant compartment D CO Engine E Rapid Action Sticky Paper F Gas hose and hoseclamp G Country specific regulator See specifications page 11 H Insect collector and Water trap Pole Asian Tiger mosquito mode J Pole Mosquito mode standard K Pole Midge and Gnat mode L Legs M Gas tank base N Anchor stakes O Safety lock P Gas tank 10 kg recommended Assembly instructions Predator Dynamic Base assembly Select preferred pole J or K depending on target and local condi tions See previous page for more information Secure all bolts tightly Base placement When the base is assembled put it in your preferred location Anchor it to the ground with the stakes Learn more about the optimal placement on page 9 Assemble CO engine and attach gas regulator on hose Connect CO engine on pole Attach the gas regulator on the hose and secure it with the hoseclamp WARNING The tubing or the flexible hose must be changed within the prescribed intervals X Check leak po
19. or car trunk Heat will cause the gas pressure to increase which may open the relief valve and allow gas to escape Place dust cap on cylinder valve outlet whenever the cylinder is not in use Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve Other types of caps or plugs may result in leakage of propane Do not store a spare gas tank under or near this appliance m Never fill the tank beyond 80 percent full n A fire causing serious injury or damage to property may occur if the above is not followed exactly o Always transport your tank in a secure well ventilated location in your vehicle gas tank should be upright with valve turned off Gas tank should be taken directly to and from place of use 8 Never attempt to attach this Predator Dynamic to the self contained gas system of a camper trailer motor home or house 9 The use of alcohol or prescription or non prescription drugs may impair the consumer s ability to properly assemble or safely operate the appliance 10 Your Predator Dynamic has been checked at all factory connections for leaks Recheck all connections as movement in shipping can loosen con nections 11 Check for leaks even if your unit was assembled for you by someone else 12 Do not operate if gas leak is present Gas leaks may cause a fire or explosion 13 You must follow all leak checking procedures before operating To prevent fire
20. outdoor social occasions Read the manual and use common sence when placing the trap Also try to reduce unnecessary still standing water in your area Water puddles uncleaned gutters old buckets etc are perfect breeding ground for mos quitoes If you do this right the result will come DIY mosquito control made easy Eliminate standing water in low spots ditches gutters and similar areas Empty receptacles that collect water eg bird baths and pot plant saucers Reduce breeding sites by keeping grass mown Mosquito netting screens can be used to provide mosquito free areas Light coloured clothing is less attractive to some mosquito species and if tightly woven can give some protection against biting Always carry personal mosquito protection in infested areas We recommend Thermacell by Amplecta which is a highly effective mobile and non toxic repel lent system that instantly protects against mosquitoes A Water Wetland B Wind direction C Distance between your house terrace and the Predator Dynamic should be a minimum of 10 meters D Placement of the Predator Dynamic mosquito trap E CO and attractant scent F UV light 360 G House terrace Predator Dynamic Operating instructions Warranty Operating Instructions Checking for Leaks Tank Gas Line Connection e Make 2 cl 2 3 oz a of leak solution by mixing one part liquid dishwashing soap with three parts water e Turn gas tank ON
21. per and dispose of properly Slide fresh Rapid Action Sticky Paper in place and remove protective paper Remove Rapid Action cover by turning counterclockwise Remove used Rapid Action attractant if necessary and properly dispose Note Rapid Action attractant lasts 30 days Remove fresh Rapid Action attractant from package if necessary Dispose of packaging properly 11 Place Rapid Action attractant back into holder with holes orienting upward 12 Replace Rapid Action Attractant cover 13 Place the Rapid Action Attractant into the multi attractant compartment 14 Check engine and gas lines for any sign of damage or missing parts Repair any problems before attempting to start 15 Reconnect gas line to gas tank by turning knob clockwise 16 Remove tank cover from empty gas tank and place on full gas tank 17 Perform leak check 18 Start following Lighting instructions 19 Wash hands with soap and water CO 00 PO Oe COIN OD Replacing Igniter Battery If you do not hear a clicking sound when the igniter button is depressed the battery may have lost its charge Replace battery as follows 1 Turn gas tank valve OFF Open battery compartment by turning cap on bottom of engine counterclockwise Remove used battery and properly dispose Place fresh AA battery into compartment negative end goes in first Secure cap by turning clockwise until it stops Start following
22. tighten firmly Placement guide Predator Dynamic Trap Placement The location of your trap is a critical variable in maximizing capture rates Most mosquito species avoid direct sunlight and wind so we recommend shaded shelte red areas preferably amongst bushes or shrubs and near any wetland area Keep the trap away from areas frequented by humans and animals Experiment with different locations to determine the most successful placement for your trap Find the sweet spot For the best performance from your Mosquito Trap first determine the source of the mosquito nuisance Mosquitoes breed in wet areas like streams marshland wooded areas and gardens Then use these rules to site the Trap Rule 1 Place the Trap between the mosquito source and areas of human activity Rule 2 Place the Trap as far away from people gt 10 meters and as close to the mosquito source as possible Rule 3 Place the Trap upwind of the mosquito source but only if you can comply with Rule 1 Mosquitoes smell pray upwinds Rule 4 Always place the Trap ina calm and shaded area Mosquitoes avoid heat and wind Patience Patience and experimentation are the keys to getting the best out of your Mosquito Trap It may take as much as 2 4 weeks of use to reduce local populations to the point that breeding cycles are interrupted You should not expect to completely get rid of mosquitoes Plan ahead and operate the trap for several weeks in advance of
23. tions in this manual may result in serious bodily injury or death or in a fire or an explosion causing damage to property g WARNING FOR YOUR SAFETY I For Outdoor Use Only I outside any enclosure p WARNING FOR YOUR SAFETY l Keep out of reach of Children I WARNING F FOR YOUR SAFETY I Read the label and these instructions before using I WARNING FOR YOUR SAFETY E 1 Improper installation adjustment alteration service or maintenance can cause injury or property damage I 2 Read the installation operation and maintenance instructions thoroughly I before installing or servicing this equipment 3 Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death a WARNING 1 This Predator Dynamic is for outdoor use only and shall not be used in a buil 2 3 ding garage or any other enclosed area Do NOT operate light or use this appliance within 3 meters 8 feet of walls Structures buildings or combustible materials It is a violation of Federal law to use this product in a manner inconsistent with its labeling This Predator Dynamic is NOT for commercial use This Predator Dynamic is for use with gas only The conversion to or attempted use of natural gas in this Predator Dynamic is dangerous and will void your warranty Gas Characteristics Gas is flammable and hazardous if handled improperly Become aware of the characteristics before using
24. to Europe and north America Rapid Action Asian Tiger Red Asian Tiger mosquito South Europe and south US Rapid Action Culex Orange Mosquito midge gnat biting flies Europe and north America only with CO Insect collector and Water trap Most mosquitoes do not like dry areas and are attracted to water Your Predator Dynamic has a tray in the bottom of its collector We recommend you always keep the water trap tray filled with water Add a 1 drop of a liquid soap to break the water surface tension Adult mosquitoes do not float on the surface and will drown instantly when they hit the water Do not use tap water as it often contains chlorine which repels mosquitoes Use rain water or filtered water only Be patient All mosquito traps need a couple of days to settle into an environment If you do not reach satisfactory results in one location and want to move the trap wait at least 3 days and watch for the catch rates to increase Do not open the catch collector if you do not have to empty clean or fill it with water If you have tried changing loca tions during more than 2 weeks we suggest you try another type of lure Your local mosquito species might not be attracted to standard attractants You can find out more about attractants at www rapidactionbiotech com Bushes and grass are good surroundings as the scents from the Predator will build up around the leafs Once you have found the sweet spot for your trap you can
Download Pdf Manuals
Related Search
Related Contents
Shedding Light on Solar Green-line - Assemblad Hoods Air Extraction/Exhaust Systems Manual_GP1500_optimized. Tamaño : Learning Resources 3046 FlexScan T561 Bedienungsanleitung Cables Direct B6LZ-601R networking cable "取扱説明書" Spivi Key Features Copyright © All rights reserved.
Failed to retrieve file