Home
Mumps Virus Real Time RT-PCR Kit User Manual For In
Contents
1. Liferiver Revision No ZJO007 Issue Date Jul 1 2012 Mumps Virus Real Time RT PCR Kit User Manual For In Vitro Diagnostic Use Only RR 0056 01 For use with LightC ycler1 0 2 0 Instrument Eo rer Obelis S A Boulevard G n ral Wahis 53 1030 Brussels BELGIUM Tel 32 2 732 59 54 Fax 32 2 732 60 03 E Mail mail obelis net CE Ws 1 aal Shanghai ZJ Bio Tech Co Ltd www liferiver com cn Tel 86 21 34680596 trade liferiver com cn Fax 86 21 34680595 2 floor No 15 Building No 188 Xinjunhuan road PuJiang Hi tech Park Shanghai China 1 Intended Use Mumps Virus real time RT PCR kit is used for the detection of mumps virus by real time PCR systems in samples like nasal and pharyngeal secretions sputum serum plasma urine C S F and etc 2 Principle of Real Time PCR The principle of the real time detection is based on the fluorogenic 5 nuclease assay During the PCR reaction the DNA polymerase cleaves the probe at the 5 end and separates the reporter dye from the quencher dye only when the probe hybridizes to the target DNA This cleavage results in the fluorescent signal generated by the cleaved reporter dye which is monitored real time by the PCR detection system The PCR cycle at which an increase in the fluorescence signal is detected initially Ct is proportional to the amount of the specific PCR product Monitoring the fluorescence intensities during Real Time allows the detection of the
2. e Use always sterile pipette tips with filters e Wear separate coats and gloves in each area e Do not pipette by mouth Do not eat drink smoke in laboratory e Avoid aerosols 8 Sample Collection Storage and transport e Collected samples in sterile tubes e Specimens can be extracted immediately or frozen at 20 C to 80 C e Transportation of clinical specimens must comply with local regulations for the transport of etiologic agents 9 Procedure 9 1 RNA Extraction Different brand RNA extraction kits are available You may use your own extraction systems or the commercial kit based on the yield For the RNA extraction please comply with the manufacturer s instructions The recommended Extraction kit is as follows Nucleic Acid Isolation Kit Cat Number RNA Isolation Kit ME 0010 ME 0012 ZJ Biotech QIAamp Viral RNA Mini extraction Kit 50 52904 QIAGEN 9 2 Internal Control It is necessary to add internal control IC in the reaction mix Internal Control IC allows the user to determine and control the possibility of PCR inhibition Add the internal control IC 1ul rxn and the result will be shown in the 560nm Channel 9 3 Quantitation The kit can be used for quantitative or qualitative real time RT PCR For performance of quantitative real time PCR Standard dilutions must prepare first as follows Molecular Grade Water is used for dilution Dilution is not needed for qualitative real time PCR detection Take positive co
3. 55
4. accumulating product without having to re open the reaction tube after the amplification 3 Product Description Mumps virus is a paramyxovirus It causes mumps characterized by swelling of the salivary glands especially the parotids and sometimes of the pancreas ovaries or testes Mumps is spread by mucus or droplets from the nose or throat of an infected person usually when a person coughs or sneezes This disease mainly affecting children can be prevented by vaccination Virions consist of an envelope and a nucleocapsid Virus capsid is enveloped Virions are spherical to pleomorphic filamentous and other forms are common Virions measure 150 250 nm in diameter 1000 10000 nm in length The genome is not segmented and contains a single molecule of linear negative sense single stranded RNA Virions may also contain occasionally a positive sense single stranded copy of the genome thus partial self annealing of extracted RNA may occur Mumps virus real time RT PCR kit contains a specific ready to use system for the detection of the mumps virus by Reverse Transcription Polymerase Chain Reaction RT PCR in the real time PCR system The master contains a Super Mix for the specific amplification of mumps virus RNA The reaction is done in one step real time RT PCR The first step is a reverse transcription RT during which the mumps virus RNA is transcribed into cDNA Afterwards a thermostable DNA polymerase is used to amplify the specific gene
5. fragments by means of polymerase chain reaction PCR Fluorescence is emitted and measured by the real time systems optical unit during PCR The detection of amplified mumps virus DNA fragment is performed in fluorimeter channel 530nm with the fluorescent quencher BHQ1 In addition the kit contains a system to identify possible PCR inhibition by measuring the 560nm fluorescence of the internal control IC An external positive control 1x10 copies ml contained allows the determination of the gene load For further information please refer to section 9 3 Quantitation 4 Kit Contents MuV Super Mix 1 vial 350u1 RT PCR Enzyme Mix 1 vial 28ul Molecular Grade Water 1 vial 400u1 Internal Control IC 1 vial 30u1 MuvV Positive Control 1x10 copies ml 1 vial 30ul Analysis sensitivity 5 X 10 copies ml LOQ 1X 10 1 X 10 copies ml Note Analysis sensitivity depends on the sample volume elution volume nucleic acid extraction methods and other factors If you use the RNA extraction kits recommended the analysis sensitivity is the same as it declares However when the sample volume is dozens or even hundreds of times greater than elution volume by some concentrating method it can be much higher 5 Storage e All reagents should be stored at 20 C Storage at 4 C is not recommended e All reagents can be used until the expiration date indicated on the kit label e Repeated thawing and freezing gt 3x should be avoided as this may
6. negative controls to different reaction plate tubes Immediately close the plate tubes to avoid contamination 3 Spin down briefly in order to collect the Master Mix in the bottom of the reaction tubes 4 Perform the following protocol in the instrument 95 C for 5sec 60 C for 30sec Fluorescence measured at 60 C 10 Threshold setting Choose Arithmetic as back ground and none as Noise Band method then adjust the Noise band just above the maximum level of molecular grade water and adjust the threshold just under the minimum of the positive control 11 Calibration for quantitative detection Input each concentration of standard controls at the end of run and a standard curve will be automatically formed 12 Quality control Negative control positive control internal control and QS curve must be performed correctly otherwise the sample results is invalid Molecular Grade Water Positive Contolqualitave aay 35 QS quantitative detection 13 Data Analysis and Interpretation The following sample results are possible Crossing point value Result Anal B 25 35 Below the detection limit or negative Selection of fluorescence channels 38 40 25 35 Re test If it is still 38 40 report as 1 PCR Inhibition No diagnosis can be concluded For further questions or problems please contact our technical support at trade liferiver com cn 2 38 Positives and the software displays the quantitative value
7. ntrol 1x10 copies ml as the starting high standard in the first tube Respectively pipette 36ul Molecular Grade Water into next three tubes Do three dilutions as the following figures Dilution of Standards 4ul Aul Aul Y WV V Y 1X107 1X10 1X10 1X 104 copiesimi To generate a standard curve on the real time system all four dilution standards should be used and defined as standard with specification of the corresponding concentrations Attention A Mix thoroughly before next transfer B The positive control contains high concentration of the target DNA Therefore be careful during the dilution in order to avoid contamination 9 4 RT PCR Protocol The Master Mix volume for each reaction should be pipetted as follows 13l 1 yl 1ul Super Mix Enzyme Mix Internal Control Sul 15l Extraction RNA Master Mix Reaction Plate Tube i PCR Instrument XPCR system without 560nm channel may be treated with 1u Molecular Grade Water instead of 1ul IC 1 The volumes of Super Mix and Enzyme Mix per reaction multiply with the number of samples which includes the number of controls standards and sample prepared Molecular Grade Water is used as the negative control For reasons of unprecise pipetting always add an extra virtual sample Mix completely then spin down briefly in a centrifuge 2 Pipet 15ul Master Mix with micropipets of sterile filter tips to each of the Real time PCR reaction plate tubes Separately add 5ul RNA sample positive and
8. reduce the sensitivity of the assay e Cool all reagents during the working steps e Super Mix should be stored in the dark 6 Additionally Required Materials and Devices e Biological cabinet e Real time PCR system e Desktop microcentrifuge for eppendorf type tubes RCF max 16 000 x g e Vortex mixer e RNA extraction kit e Real time PCR reaction tubes plates e Cryo container e Pipets 0 5 ul 1000 ul e Sterile filter tips for micro pipets e Sterile microtubes e Disposable gloves powderless e Biohazard waste container e Refrigerator and freezer e Tube racks 7 Warnings and Precaution Carefully read this instruction before starting the procedure e For in vitro diagnostic use only e This assay needs to be carried out by skilled personnel e Clinical samples should be regarded as potentially infectious materials and should be prepared in a laminar flow hood e This assay needs to be run according to Good Laboratory Practice e Do not use the kit after its expiration date e Avoid repeated thawing and freezing of the reagents this may reduce the sensitivity of the test e Once the reagents have been thawed vortex and centrifuge briefly the tubes before use e Prepare quickly the Reaction mix on ice or in the cooling block e Set up two separate working areas 1 Isolation of the RNA DNA and 2 Amplification detection of amplification products e Pipets vials and other working materials should not circulate among working units
Download Pdf Manuals
Related Search
Related Contents
Fiche de sécurité /Jll ,.L` t} operation and service information Tabelas de Carga - Genie Industries Skipper CE (IT) Visualiser le sommaire Qsan Technology AegisSAN F300Q Operating Instructions TFT colour display 1286 .. - Copyright © All rights reserved.
Failed to retrieve file