Home
ETCR9500_9500B user manual
Contents
1. ETCR Wireless HV CT Ratio Tester ETCR 9500 ETCR 9500B elas MANUAL ETCR Electronic Technology Co Ltd CONTENT WAINING 0 eee eeeeeeeeeeeeneeeeeeeeeeeeeeteaeeeeaeeteaaeeseaeeessaeeeeeeeeeeeeseaeeeeaaes 1 Introduction oo eee eee eect ee eeeeeeeeeeteaeeeeaeeeeaeeeesaeeeeeeeteeeeesaeeeeas 3 H BleCtrIGAlsSYMNDOlSxccexscseta cad sad cedcadececneeetharea rea a aan eaeee 4 IM Technical Specifications 1 lt c tcx2 cest enedesedendetncecatetacasanecanecateceaeats 5 TV SUC e oes osc cnet 2 cael ez a es cath tes ted tate tac ni ioiaindnipieinisiainis 7 V NIV eA OTM Sa hs a a ah i a ea 7 1 Switch of high voltage detector eeeeeeceeseeseteeeeeseeees 8 2 Switch of MAIN CNGING eee eseetseeeeeeeeseetseeteaeeeseeeeees 8 3 Detection ON HV CUITeNt eee eeeeeeeneeeeeeeeeneeeeeeeeeeaeerns 9 4 Detection on LV current sueseesiesiserieerieerirerrrsrrrerrreere 11 5 Transformation Ratio measurement eeeeeeeeeeeteeeees 13 6 Data keeping and delete 0 0 00 ee eeeeeeneeeeseeeeeneeeeeeeeens 15 7 Data storage eee 15 8 Data Search cccianeadanadaneandanadanadannn 15 Oy Data de etOi a a ENERE 16 VI SoftWare ar n e ce ree aa 16 1 Real time monitoring page 17 2 Historical data page eeeseseeeeseeeeeseeeseneeeeeeeeeeeeeseeeeeas 17 VI Replace battery eeceeeseeesseeeeseeeeeeneeeeaneseeeeesneeneseeeennes 18 WIM PACKING
2. TES BEPPE A T 19 A Warning AN Thanks for purchasing Wireless HV Current Transformation Ratio Tester from our company In order to have better use of this product make sure that Read this manual carefully before conducting field tests the operator shall fully understand guidelines in this manual Comply with safe rules and notices listed in this manual completely u In any cases safety shall come first when using this Tester especially in which the voltage circuit bears the voltage of AC 100V or more u Incase that the voltage circuit bearing the voltage over 600V is to be tested the Tester shall be applied connecting insulating rod with the hand holding on the fifth knot of it u Dueto risk of high voltage lines operators shall have accepted rigid training and gained related certification for high voltage operation before conducting field test with this Tester u Take notice of characters and symbols labeled on the face board and back board u Please do not place or store the Tester under direct sunshine in high temperature or moist places or places apt to be dewed u Take notice of the polarities of the battery when doing replacement remove the battery from the Tester if it is kept idle for a long time u Disassembly and maintenance of this Tester shall be done by operators with authorization u Please do not use Testers whose binding clips and other parts are broken u Avoid attacking binding clips
3. automatically power failure or battery replacement will not cause data missing Line voltage Test for lines bearing voltage below 60kv insulating rods with five knots must be used Data hold Press HOLD to hold the data and sign of Hold appears press it again holding will be canceled Data search Press HOLD and POWER to enter the mode of data search Overflow display Outrange overflow OL A appears No signal When the main engine does not receive transmit instruction signals present No Signals Automatic 15 minutes after starting up the tester will shutdown shutdown automatically Battery When battery voltage is below 4 8v sighs will remind voltage you of replacement Tester quality Main engine about 240g including battery High voltage detector about 335g including battery Low voltage needle point current clamp about 190g Total weight about 2 5kg including insulation rod and battery External No super strong electromagnetic field no same interference frequency interference of 433 MHz and 315 MHz Working temperature and humidity 25 C 45 C below 80 Rh Storing temperature and 10 C 60 C below 70 Rh humidity Insulation rod 932mm 1m know standard configuration five knots size extendable mace Standard 2 meters lengthen according to the on site current clamp length Insulation strength High voltage d
4. if the instrument has secondary current indication of OL the secondary current exceeds instrument work holding jaws upper current limit 3 Reference illustrations AN Clamp electricity wire and zero wire at the same time leakage current could be detected note total 2 wires Clamp the ground wire the leakage current could be measured note single wire Clamp the main line total current amount could be measured note single wire Where its numeral reading is not easily accessible use high voltage detector to examine the current on low voltage wire 1 Examine if there is a leaker First current no signal Secondary current 35 0MA 2 Detect the equipments leaker L Detect a motor s leaker First current no signal Secondary current 35 0MA 3 Detect leaker of ground wire Ground Wire First current no signal Secondary current 35 0MA 5 Transformation Ratio measurement Primary current The current collected with high voltage current pliers is mutual inductor s first current Secondary current The current collected with low voltage current pliers is mutual inductor s secondary current Ration based on secondary current 5A The measured secondary current value is converted to be 5A then convert the first current based on that ratio the same transformation ratio Display Ratio The ratio between the fir
5. make the detector continue to work Press POWER will shut down it 2 Switch of main engine Wireless HV CT Tester Press POWER to start the engine and LCD displays After the normal startup the main engine will enter test receiving mode see the picture below The primary current is the testing data of high voltage terminal while the secondary current the low voltage In case that signals are detected in both primary and secondary circuits the main engine will show the transformation ratios on the basis of secondary circuit bearing current 5A If transformation ratio is too high which means that the current value in the primary circuit is large while it in the secondary is small the ratio surpasses 1000 000 i e x xxxK6 x xxxx10 is displayed the numeral value behind K means the power of 10 Of course this phenomenon will not occur in the normal operational circuit In data search mode press POWER key and shift the cursor to return return to the test mode by pressing the off by pressing the POWER key 3 Detection on HV current HOLD key power personal injury or casualty High voltage very dangerous Nobody but a qualified personnel after training could conduct operation on it The operator should obey safety regulations otherwise there will be the danger of electric shock resulting in or casualt
6. transmission distance is about 30m The HV LV high accuracy clamp ammeter can be used to measure the current and leakage current varying from 0 01mA to 1000A HV clamp ammeter can also measure LV current Current clamp In order to make sure of the high accuracy stability and reliability during any monitoring at any time the entire year special alloy is selected and latest CT technology plus magnetic shield technology almost resistant to external magnetic field are adopted Main engine Gorgeous blue LCD presents you clear information at a glance and it possesses super large memory space capable of storing 3 000 sets of data Monitoring Software Functions such as real time monitoring and historical data search is available as well as curve drawing ratio max min average indication alarm value setting There are also functions such as data documents saving and historical report printing High voltage detector It connects five knots of insulation rods and applies in test of high low voltage lines bearing the voltage below 60K V its dedicated high voltage current clamp can easily clip or withdraw the lines to be tested by pressing down or unplugging back the insulation rod which saves time and runs effectively so it is widely used for substation power plant power audit department industrial and mining establishments as well as check station electrician maintenance departments to conduct current detection opposing electricity st
7. 6282512 36282505 Fax 086 20 36282515 Email info etcr cc Website http www etcr cc
8. Ax4 keeps a continuous work for 30 hours Test way Clip on CT Transmission way Wireless transmission with direct line transmission distance about 30m Display mode LCD 128dotsx64dots Blue screen backlight suitable for dark places LCD dimension Display area 44mmx27mm Width x Heightx Thickness Tester size Main engine 75mmx170mmx30mm HV Current Clamp 76mm X 255mm x 31mm LC Current Clamp 175mmx70mmx38mm Clamp HV Current Clamp 948mm Dimension LC Current Clamp 925x30mm Sampling speed About 3 times second Measurement High voltage detector 0 1mA 1000A range Low voltage current clamp 0 01mA 6A High voltage detector 0 1mA Resolution ogi current clamp 0 01mA Gearing Automatic gearing Measuring 0 0mA 299mA 1 3dgt accuracy of the 0 30A 49 9A 1 5 5dgt primary circuit 50 0A 199 9A 2 5dgt 23 C 43 C below 200A 600A 3 5dgt 80 RH 601A 1000A 4 5dgt Measuring accuracy of the 0 00mA 6A 1 3dgt secondary 23 C 3 C below 70 RH circuit Transformation Three kinds of measurement of actual circuit transformation ratios primary secondary ratio transformation on the basis of secondary circuit bearing current 5A transformation on the basis of 10kV YY of 10kV 380V transformer and the Max ratio is 1 100 million 1 0K8 Data storage 3 000 sets press HOLD to hold the data ynumber and store
9. and maintain the Tester regularly Soft cloth e g glasses cloth moistened by clean antirust and dehumidified lubricant e g WD 40 instead of corrosive agent or rough issues shall be used to gently rub down the Tester u Incase that continuing use will cause safety hazard due to the performance of the Tester itself stop using it and mothball it at once then leave it to authorized organization for handling u When contacting the sign A dangerous users shall follow the directions on the Tester and manual to do safe operation u When contacting the sign extremely dangerous users shall rigidly follow the directions on the Tester and manual to do safe operation u It is suggested to test the insulating strength for this Tester at least one time a year AC100kV rms section between the fifth knot of insulating rod I Introduction ETCR9500 Wireless HV Current Transformation Ratio Tester breaks through the traditional structure specializing in on line measurement of high voltage current transformer in service under 60KV primary and secondary current of transformers transformation ratio and leakage current ETCR9500B also with phase polar ratio difference angle difference Indication It consists of high voltage detector low voltage secondary current clamp main engine high voltage insulation rods The wireless transmission signal is able to penetrate obstacles such as walls of buildings The signal s direct line
10. ealing outdoors electrical operation etc The insulation rod is characterized by lightless moisture protection high temperature resistance shock resistance bending resistance high insulation flexibility and so on ETCR9500 Wireless HV Current Transformation Ratio Tester is called Wireless Transformation Ratio Tester for high voltage meanwhile it can function as high low voltage clip on ammeter for high altitude current tester high altitude leakage current tester clip on leakage current meter with high accuracy and other products II Electrical Symbols Extremely dangerous Operators shall rigidly follow the safe rules or the potential electric shock will cause personal injury or death Dangerous Operators shall rigidly follow the safe rules or the potential electric shock will cause personal injury or death A Warning The safe rule shall be followed completely or a personal injury or damage to equipments will arise Alternating current AC Direct current DC III Technical Specifications Function On line testing for current transformation ratio and leakage current of primary secondary circuit of high low voltage current transformation on line testing for current and transformation ratio between two sides of the transformer Phase polar ratio difference angle difference indication is also available on ETCR9500B Power source DC6V alkaline dry battery 1 5V AA
11. etector AC100kV rms section between the fifth insulation rod and the clamp core of high voltage current clamp Main engine and low voltage current clamp AC1000V rms Structure Antidrip II high voltage detector IV Structure High voltage detector Main engine Low voltage current clamp 1 High voltage current clamp 2 LED power indication of HV detector 3 Power key 4 Joints of insulation rods 5 Input interface for low voltage current 6 LCD monitor of the main engine 7 HOLD key 8 RS232 Interface 9 Output plug for low voltage current clamp 10 Low voltage current clamp V Operation Before using the tester examine whether there A N is any part broken if no it can be put into use Install the battery according to the manual 1 Switch of high voltage detector Press POWER to start the detector and the POWER indicating light is on The detector will begin to do automatic detection and send the result to the main engine by wireless transmission If the indicating light keeps flickering about 15 minutes after the detector is started this will present an automatic shutdown and after it keeps flickering for about 30 seconds the detector will be shut down automatically to reduce battery consumption During the flickering of the POWER indicting light pressing POWER will
12. ncreased or reduced by 100 search and view the cycled data stored downward or upward Shift the cursor to ESC the return position press the HOLD key exit from the data search mode back to the detection mode 9 Data deletion In data search mode press the POWER key and shift the cursor tothe delete DEL position then press the HOLD key YES to delete all the stored data and return to detection mode it is not possible to restore the data just being deleted VI Software The Minitoring and data upload software have to be installed and run on the computer base on Windows XP 2000 OS Monitoring Software Functions such as real time monitoring and historical data search is available as well as curve drawing ratio max min average indication alarm value setting There are also functions such as data documents saving and historical report printing 1 Real time monitoring page las Corwane oe Taine Caeang ab Carrs Share ise Co eg e sal f l lis Red Curve indicates the primary current and green curve indicates the secondary Curve zoom in and out Click on the left key no release of the mouse and move the mouse 2 Historical data page a dm De i Historical Data Se ee Ss Loo ae eee a ere Bt bes tte mite yo or Historical data process read access saving analyse Sequence draw curve print VI Re
13. place battery Caution No detection could be conducted h when the battery cover is not properly closed otherwise there is danger Pay attention to battery electrode otherwise it will do harm to the instrument 1 When high voltage detector has its battery voltage below 4 8V its main set flashes with When the main set has its battery voltage below 4 8V the main set displays the low voltage icon indicating that the battery is short of power replace the battery 2 Power off confirm that the instrument is shutdown Loosen the 2 screws on the battery cover open the battery cover and replace with new qualified batteries Paying special attention to the size and electrode close the battery cover tighten the two screws 3 Press the POWER key to examine whether the instrument is normally stared up if not re operate according to step 2 Battery Cover Battery Cover Loosen Tighten Loosen it by turning the 2 screws counter clockwise Tighten it by turning the 2 screws clockwise Vil Packing list High voltage detector 1 unit Main set 1 unit Low voltage current pliers 1 unit Insulation bar 1 M pc 5 pcs Instrument box 1 pc Manual warranty card certification 1 unit A Manufactured by Guangzhou ETCR Electronic Technology Co Ltd Address B 3F North Jixian Industrial Park North Baiyun Avenue Guangzhou Postcode 510440 Tel 086 20 3
14. st current and secondary current by actual measurement 10kV YYconversion ratio high voltage detector collects the secondary bus current The ratio between transformer s first current and mutual inductor secondary current could be calculated by transformer 10kV 380V As above described concerning high voltage detector and the first and secondary return circuit clamped by low voltage current pliers the main set has an indication of the first and secondary current number and tranformation ratio if the first current is 680A the secondary current is 2 00A its current ratio is 340 0 calculated based on the secondary loop circuit 5A the transformation ratio is 1700 5A which is 5 2X 680 the 10kV 380V transform has a transformation ratio of 12 9 the first current to the secondary current of mutual inductor which is 340 10kV 380V 1st 2nd 680A 2 00A 680a 2 00a Ratio 340 5ARatio 1700 5A 1700 5A 10KV YYRatio 12 9 Detection display mode Conversion ratio display mode In detection mode press the HOLD key for 3 seconds enter the conversion display mode as shown above on the right diagram the first second loop current 10kV YY conversion ratio Press the HOLD key for 3 seconds exit from the conversion ration display mode return to the start up detection mode In the ratio conversion mode click the HOLD key to set the second time c
15. t on high voltage end If the main set fails to receive the signal sent by the high voltage detector the first current is indicated to be no signal for the primary loop If the main set has OL as its first currency indication that means that the first current exceeds the upper limit of the high voltage detector Push the insulation rod backward the high voltage detector is disconnected with the wire As shown in Diagram C Do make every effort to keep the guide sector perpendicular to wire upon withdrawing Cable SN iS SO gt Forward Pull Backward DiagramA Diagram B Diagram C A Notice For the sake of safety please take the instrument away from the wire after the detection is finished 4 Detection on LV current High voltage very dangerous Nobody but a qualified personnel after training can conduct operation on it The operator should bear safety regulations in mind otherwise there will be the danger of electric shock resulting in personal injury or casualty Low voltage current pliers are not allowable to detect high voltage wire above 600V or 6A otherwise there will be the danger of electric shock resulting in personal injury or casualty 1 Connect low voltage current pliers and main set turn the main set on enter the detection mode 2 Have low voltage current pliers clamp the wire notice it is fully closed examine the current numerical reading
16. urrency base number and conversion ratio is calculated press the POWER key to shift the cursor Press the HOLD key for 3 seconds exit from the conversion ratio display mode return to the start up detection mode Each time the instrument starts up with the secondary current 5A being the default conversion ratio 6 Data keeping and delete In detection mode press the HOLD key for LCD display of the HOLD symbol Press the HOLD key to release the data lock return to the detection mode the HOLD symbol disappears 7 Data storage In detection mode press the HOLD key for data holding the instrument will store the data and remind you the total stored data number The instrument has a data storing capability of 3000 groups If the stored data is full there is a symbol indication of FULL clear the memory for next data storage 8 Data search In detection mode press both the HOLD key POWER key to enter the data search mode meanwhile the detector will auto display the group 0001 data Now press the POWER key and shift the cursor press the HOLD key to confirm The instrument are designed with fast search function from 1 1 10 10 stored data press the HOLD key once search in increased reduced order shift the cursor on 10 10 position press the HOLD key data number could be i
17. y Only when all of the five insulating bars are connected can the high voltage line be detected otherwise there may be the danger of electric shock resulting in personal injury Dangerous It is not allowable to measure high voltage line above 60V otherwise there will be danger of electric shock resulting in personal injury or casualty high current wire above 1000A Dangerous It is not allowable to detect the Prior to the detection have the insulation bars connected properly finally have the detector connected for avoidance of any ground impact on the instrument Nothing but the special made insulation bars A could be connected to the instrument After the detection collect the insulation rod in slant direction first take apart the detector then the insulation bars for the avoidance of ground impact on detector High voltage detector is connected properly with 5 insulation rod and started normally Set the detected wire at the center of guide sector on detector pliers head Diagram A High voltage detector has guide sector perpendicular to wire Push forward the insulation rod the wire detected is clamped by the high voltage detector which starts detection and feedback to the main set Main set enter detection and data collection state after its normal starting up If the main set receives the signal sent by the high voltage detector there will be a live indication of current amoun
Download Pdf Manuals
Related Search
Related Contents
Thank you for purchasing your new CAMSPORTS helmet sports Velleman MICW43 User manual ATH-CP500i 取扱説明書 OptiMate 3 Der einzige Batterieoptimierer der rettet, lädt, testet und 表示に関する業界自主ルール(平成 22 年度) Manual de Instruções(SOM).cdr 藍藍甕居夏雪景慕遠望~こて喜亭も響雲霧皇皇嘉精三重顎模管して(*ョ Diplom 2011 COBY electronic TF-DVD1256 User's Manual Copyright © All rights reserved.