1. Finder 13 3 2 Access from a Web Browser rarrarnarnnrrnnrnanennrnnrnnnnnernennnnnnenernnnnnneneennene 14 3 3 Access from the Internet oocoocconcconcociconconiococonoonoonononnonoononnnnanonnonono 15 3 4 Setting the Admin Password Over a Secure Connection 15 LEVEN Pet 16 3 6 Network Camera Se tup cccc cece cece eee e cece eee eee ne nennen 18 V EasyNet ex 4 HD CAMERA 1 Introduction About This Manual Thank you for purchasing our EasyNet EC 2M OV39N ONV HD Camera This full featured camera comes equipped with a progressive scan imager which transmits at high definition 1920 x 1080 resolution as well as enhances low light sensitivity and provides crystal clear pictures even in challenging lighting environments 1 1 Key features Brilliant video image utilizing H 264 video compression Triple network streams simultaneously in full HD 1920x1080 CIF 852x240 and MJPEG 352x240 for increased flexibility depending on the various environments Motorized lens where it is capable of adjusting zoom and focus without ever touching the knob of the lens module Smart Focus where focus is adjusted automatically when camera goes into Night mode or Day time mode oimple zoom and focus using equipped wired service cable and controller Hemote Focus and Zoom over the network Power over Ethernet utilizing 802 3af standards so that video and
2. Settings for more details Connect to 197 168 127 710 The server 192 168 12 210 at Hitron Systems requires a username and password Warning This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection User name Password Remember my password Cancel To prevent network eavesdropping when setting the admin password this can be done via an encrypted HTTPS connection which requires an HTTPS certificate see note below To set the password via a standard HTTP connection enter it directly in the first dialog shown below To set the password via an encrypted HTTPS connection see 3 5 4 System gt Security gt HTTPS Note HTTPS Hypertext Transfer Protocol over SSL is a protocol used to encrypt the traffic between web browsers and servers The HTTPS certificate controls the encrypted exchange of information bd amp EasyNet HD CAMERA 3 5 Live View Page The live view page comes in several screen modes like 1920x1080 1280x1024 1280x720 704x480 576 640x480 352x240 288 and 320x240 Users are allowed to select the most suitable one out of those modes Please adjust the mode in accordance with your PC specifications and monitoring purposes Qivceo Dio ere vw Live View p JG PG PA PAN a v i uy Q ow a eo au 1 General controls Je uy EN Live View Page Search Playback Page Set
3. power can be used over single cable No extra power outlet or power source is needed For increased flexibility the camera also comes equipped with 24VAC to be used with heater as well as instances where Power over Ethernet is not being used Ed EasyNet o HD CAMERA D amp 1 Introduction 1 2 Content Verification Before installing the camera please make sure that all of the following items are included in the box 1 EC 2M OV39N ONV HD Camera 2 Installation Guide 3 Mounting Template Sheet 4 Service Monitor Cable and Controller 5 Accessories Kit V EasyNet RON O amp HD CAMERA 1 Introduction 1 3 EC 2M OV39N HD Camera Dimensions Unit inches Ve EasyNet _ E Os HD CAMERA 2 Installation and Configuration 2 1 Installation The dome camera is for use in surface or pendent mounting applications and the mounting member must be capable of supporting loads of up to 3 3lb 1 5kg Pendent mounting must use pendent mount accessory The dome camera s mounting bracket should be attached to a structural object such as ply wood wall stud or ceiling rafter that supports the weight of the dome camera Ceiling Wall Mounting Template Sheet Bottom Case IR Gimbal Bracket IR Board Motorized Lens Top Case Bubble E M bom J CT KA Easy Net o amp HD CAMERA 2 Installation and Configuration 2 2 Adjusting 3 Axis Gimbal The Gimbal mechanis
4. screen to set the focus to the optimum position KA EasyNet __ HD CAMERA 3 6 Network Camera Setup This section describes how to configure the network camera and is intended for product Administrators who have unrestricted access to all the Setup tools Operators who have access to the settings for Basic Live View Video amp Image Event and System Configuration You can configure the network camera by clicking Setup in the top right hand corner of the Live View page Click on this page to access the online help that explains the setup tools When accessing the Network Camera for the first time the Admin Password dialog appears Enter your admin name and password set by the administrator Connect to 197 168 12 210 Th 192 168 12 210 at Hitron Syst i cea LT Note If the password is lost the Network Camera must be reset to the factory default Warning This server is requesting that your username and password be sent in an insecure manner basic authentication settings without a secure connection User name Password Remember my password There are more advanced parameters that can be managed please refer to the NUVICO Network Video Recorder manual for complete configurations and operations instructions all KA Easy Net
5. 92 168 1 103 0 0 0 0 169 254 75 101 20 7 T3 release Group EC 2M OV39N ONV H 264 Motorized IR Full HD 5C 69 84 00 7B B8 192 168 1 110 0 0 0 0 169 254 75 119 1 5 9 T4 release EC 2M B3N ONV H 264 Network Bullet Camera 5C 69 84 00 5D 79 192 168 1 105 0 0 0 0 169 254 238 216 1 5 9 T4 release 3 Select the camera on the list click the right button of the mouse You can see the pop up menu as below SmartManager Ed cm es 7 IP Filter 192 168 12 205 e 192 168 12 206 Apply F3 Model Name MAC Address IP Address Version La All Devices 2 salen 00 07 D8 10 18 14 192 168 12 206 amp HDG T312 NSRAB Remote Setup m Q ONVIFC i 4 Group Maintenance 3 LogIn Open Web Page N Emergency Firmware Upgrade 4 Select Assign IP You can see a Assign IP window Enter the required IP address Assign IP Address Assign new IP address Camera Information Model HD G T312 HSRA8 Name HD G T3120007D8101814 MAC Address 00 07 D8 10 18 14 IP Address 192 168 12 206 Cancel eos PN EasyNet 13 3 Program and Operation The Network Camera can be used with Windows operating system and web browsers The recommended web browsers are Internet Explorer Safari Firefox Opera and Google Chrome with Windows Note To view streaming video in Microsoft Internet Explorer set your browser to allow ActiveX controls 3 2 Access from a web browser 1 Start a web browser 2 Enter the
6. Close the lens cover CAUTION When performing a Factory Reset you will lose any settings you have saved Please consult with NUVICO Technical Support first before doing so since this can ind phe communication to the recorder 5 EasyNet 12 amp RON HD CAMERA 3 Program and Operation 3 1 Detecting IP cameras with IP Cam Finder IP Cam Finder utility automatically discovers and displays NUVICO IP Cameras on your network So please download the IP Cam Finder from http www nuvico com downloadfile htm id 430 The factory default IP is 192 168 30 220 1 Connect the Network Camera to the network and power up 2 Start IP Cam Finder utility Start gt All Programs IP Cam Finder gt IP Cam Finder the main window will be displayed After a short while any network devices connected to the network will be displayed in the list Pele m i File View Help oo a zu mammi Model Name Name MAC Address IP Address Wireless IP Address Zero Conf IP Version La All Devices 6 EC 2M D39N ONV H 264 Motorized Full HD C 5C 69 84 00 5C D1 192 168 1102 0 0 0 0 169 254 81 63 20 7 T3 release IES estic EC 2M OV39N ONV H 264 Motorized IR Full HD 5C 69 84 00 78 74 208 88 59 166 0 0 0 0 169 254 115 63 1 59 T4 release a e ji EC 2M B3N ONV H 264 Network Bullet Camera 5C 69 84 00 5D 83 192 168 1107 0 0 0 0 169 254 63 48 1 59 T4 release owr 6 EC 2M D39N ONV H 264 Motorized Full HD C 5C 69 84 00 5B F3 1
7. Disclaimer e While every effort has been made to ensure that the information contained in this guide is accurate and complete no liability can be accepted for any errors or omissions e NUVICO reserves the right to change the specifications of the hardware and software described herein at any time without prior notice e No part of this guide may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form by any means without prior written permission of NUVICO e NUVICO makes no warranties for damages resulting from corrupted or lost data due to a mistaken operation or malfunction of the cameras peripheral devices or unapproved unsupported devices Warning and Caution WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OPENINGS ON THE EQUIPMENT CAUTION RISK OF ELECTRIC SHOCK iu NOT OPEN Ley y CAUTION CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The e
8. ERA Important Safeguards e Read these instructions e Heed all warnings e Follow all instructions e Do not use this equipment near water e Clean only with dry cloth e Do not block any ventilation openings Install in accordance with the manufacturer s instructions e Do not install near any heat sources such as radiators heat registers stoves or other equipment including amplifiers that produce heat e Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet e Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the equipment e Only use attachments accessories specified by the manufacturer e Unplug this equipment during lightning storms or when unused for long periods of time e Refer all servicing to qualified service personnel Servicing is required when the equipment has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the equipment the equipment has been exposed to rain or moisture does not operate normally or has been dropped e CAUTION
9. IP address of the Network Camera in the Location Address field of your browser 3 You can see a starting page Click Live View Playback or Setup to enter web page Network Dome Camera Live View Playback Setup 4 The encoder s Live View page appears in your browser Q sues mi iv lova we Bt HTP ki KUNST Hod sa mk EasyNet 3 3 Access from the internet Once the Network Camera is connected to the Internet it is accessible on your local network LAN To access the video encoder from the Internet you must configure your broadband router to allow incoming data traffic to the video encoder To do this enable the NAT traversal feature which will attempt to automatically configure the router to allow access to the video encoder This is enabled from Setup gt System gt Network gt NAT For more information please see 3 5 4 System gt Network gt NAT of User s Manual 3 4 Setting the admin password over a secure connection To gain access to the product the password for the default administrator user must be set This is done in the Admin Password dialog which is displayed when the network camera is accessed for the setup at the first time Enter your admin name and password set by the administrator Note The default administrator username and password is admin If the password is lost the Network Camera must be reset to the factory default settings See 3 8 Resetting to the Factory Default
10. THIS MANUAL IS FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY TO RE DUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO e Use Certified Listed Class 2 power supply transformer only 1 EasyNet a HD CAMERA 3 amp Table of Contents 1 Introduction arrarnarnnrnurnnrnnrnnrnnrnnrnernernennernennennennennsnnsnnsenn 5 About This Manual ocooccocconconconioniociociocconnonnonnonnonnnnnonnonnonnonnonncnnonnonncnnennnnnos D 1 1 Key features er ser 5 1 2 Content Verification ooccoonconcconconnconncorocononnncnnocanonnnonronanonononnonanonnnennnnns 6 1 3 EC 2M OVS39N ONV HD Camera Dimensions 7 2 Installation and Configuration esse 8 2 1 Installation ooccocconconccnccnocconconecnonnononnnononnononnonnonncnnnnnnronnonnonnnnnnnnnnnnos 8 2 2 Adjusting 3 Axis Gimbal oocccccccnccccnncocicocncocnnonnconnnonnnonnonononanonononanonaness 9 2 3 Connection Cable rrrnnnrnnnnenaneranennrennrenunerunernnernnennvernvennnennnennesnnusenusener 10 2 4 Using Service Monitor Port and Wire Controller 11 2 5 Resetting to the Factory Default Settings oocccoccconnococnconnnnnonenanonnns 12 3 Program and Operation rrarenanenanenanenanennnennnenanennnennnen 133 3 1 Detecting IP Cameras with IP Cam
11. e computer keyboard to cancel full screen view ID Fi The Manual Trigger button activates a pop up window to manually start or stop the event The Remote Focus button enables users to adjust focus and zoom remotely via network E The Smart Focus button readjusts focus automatically 3 Video Streams The Network Camera provides several images and video stream formats Your requirements and the properties of your network will determine the type you use The Live View page in the Network Camera provides access to H 264 MPEG 4 and Motion JPEG video streams and to the list of available video streams Other applications and clients can also access these video streams images directly without going via the Live View page 4 Focus and Zoom Control You can control Zoom and Focus in the live screen Press the button on the left top in the live screen to activate the Zoom amp Focus control panel Streami iv ies gir wi Live View a aa 2 Q 3 Motorized Full HD C f S http 192 168 34 56 live lens cont UT ELIT e t INTE AA ES Adjusting Zoom E o 192 168 34 58 00000001 8 Click button to zoom out and click button to zoom in The focus is moved slightly after adjusting zoom adjust the focus again as necessary Adjusting Focus mr Rs Click button for far focus and click button to near focus Note Click the E button in the live
12. er to the service monitor port then using your own handheld service monitor press buttons to zoom in or zoom out to desired focal length Lastly use the buttons to adjust the focus 2 Change Camera ID and IP Address INFORMATION On rare instances if you must you can change the BID 001 Name or Title and IP address of the camera NAME EC 2M OV39N ONV Please consult with NUVICO Technical Support first before doing so since this can interrupt the communication to the recorder IP 192168 0 1 SAVE CANCEL wo o e EasyNet SPN HD CAMERA 11 2 Installation and Configuration 2 5 Resetting to the Factory Default Settings To reset the EC 2M OV39N HD Camera to the original factory settings use the Reset button SW1 on the board of the dome camera as described below Bottom Case Factory Reset Button SVI Using the Reset Button Follow the instructions below to reset the HD Camera to the factory default settings using the Reset button 1 Power off the HD Camera by disconnecting the power adapter or Cat5e Cat6 network cable if it is connected to Power over Ethernet 2 Open the lens cover 3 Press and hold the Reset button SW1 on the board with your finger while reconnecting the power 4 Keep the Reset button SW1 pressed during about 2 seconds 5 Release the Reset button SW1 6 The HD Camera resets to factory defaults and restarts after completing the factory reset 7
13. m yields maximum rotation and placement as shown below e Z Axis Rotation 355 Y Axis Tilting 70 e X Axis Panning 355 Rotation 355 O Tilting 70 5 Panning 355 KA EasyNet HD CAMERA 2 Installation and Configuration 2 3 Connection Cable NO Hed 24VAC White 24VAC GND Main Power 2pin terminal 24VAC 20VA or 8 4W Heater Power 2pin terminal 24VAC 40VA or 20W Green 24VAC mn To use the built in heater 24VAC power supply must be Black 24VAC GND connected to this dedicated input Pink Alarm In Yellowish Green Gup arm Input AD Key Input Alarm Output 3 Yellow AD Key 6pin terminal Brown GND Light Blue Alarm Out Gray GND Disabled All Alarm controls are executed through NUVICO Network Video Recorder 4 Black Ethernet RJ 45 port compatible with 10 100Mbps having Power over Ethernet functionality Modular Jack 5 Audio line input RCA Jack Disabled Audio line output RCA Jack Disabled Es Easy Net 10 serene HD CAMERA 2 Installation and Configuration 2 4 Using Service Monitor Port and Wire Controller Bottom Case a Service Monitor OSD Controller L e Micro SD Slot Service Monitor amp OSD Controller Communication Port service monitor output port J3 is located on the board of the dome camera and is used for two purposes r 1 Adjust zoom and focus Once you connect the wire controll
14. up Page Help Page Q9 vipeo v The video drop down list allows you to select a customized or pre programmed video stream on the live view page Stream profiles are configured under Setup gt Basic Configuration gt Video amp Image For more information please see 3 5 1 Basic Configuration gt Video amp Image of User s Manual 4CIF 704x480 N The resolution drop down list allows you to select the most suitable one out of video resolutions to be displayed on live view page HTTP The protocol drop down list allows you to select which combination of protocols and methods to use depends on your viewing requirements and on the properties of your network 2 Control toolbar The live viewer toolbar is available in the web browser page only It displays the following buttons w The Stop button stops the video stream being played Pressing the key again toggles the start and stop The Start button connects to the network camera or start playing a video stream The Pause button pause the video stream being played The Snapshot button takes a snapshot of the current image The location where the M E B image is saved can be specified The digital zoom activates a zoom in or zoom out function for video image on the live screen e ed OX N 16 AS SA Easy let x The Full Screen button causes the video image to fill the entire screen area No other windows will be visible Press the Esc button on th
15. xclamation point within an equilateral is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance KA EasyNet HD CAMERA FCC Compliance Statement FCC INFORMATION THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE PURSUANT TO PART 15 OF THE FCC RULES THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT THIS EQUIPMENT GENERATES USES AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES 003 CET APPAREIL NUMERIQUE DE LA CLASSE A EST CONFORME A LA NORME NMB 003 DU CANADA CE Compliance Statement WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES V EasyNet RON 2 HD CAM

Download Pdf Manuals

image

Related Search

Related Contents

User manual_IOG_DE  ThinkCentre Hardware Maintenance Manual  取扱説明書 AS192M - ログイン|製品比較システム管理  Microlife BP A100 Plus  Quelles innovations entre intelligence de la tâche  Samsung F1035AS 用户手册  USER GUIDE - Derrier Loisirs  Philips PowerPro Telescopic Tube for vacuum cleaner CRP743  HGST Desktop Drives XL Desk 3TB  KK-DH27-10取扱説明書(PDF:4958KB)  