Home
Siemens VersiCharge™
Contents
1. 4 Ready 5 Fault 6 Remote Control Activated 7 Service Portal 8 Time Delay 9 Hour Delay 10 Remote Control Lock 4 5 6 10 9 9 2014 Siemens Industry Inc 813776 SIEMENS 2 3 Mounting Bracket Receptacle not Included 1 Mounting Holes 2 Receptacle cutout 3 Mounting Slot 4 Mounting Tab r GROUND STUD FACING UP sos WALL STUD FACING DOWN 1 2 ORIENTATION DETAIL ORIENTATION DETAIL RECEPTACLE MUST BE MOUNTED ON LEFT SIDE FOR THIS CONFIGURATION MOUNTING BRACKET RECEPTACLE BOX BE MOUNTED ON EITHER NEMA 5 50 SIDE OF STUD IN RECEPTACLE THIS CONFIGURATION 4 6 GENTER 8 B RECEPTACLE TO CENTER OF RECEPTACLE 18 MIN 6 50 RECEPTACLE REAR FED HIDDEN PLUG MOUNTING BOTTOM FED EXPOSED PLUG MOUNTING 10 2014 Siemens Industry Inc 813776 SIEMENS 2 4 Exterior Rear 1 Mounting Tabs 2 Fed from behind wiring option 3 Fed from the bottom wiring option 4 EV Cord 11 2014 Siemens Industry Inc 813776 SIEMENS 2 5 Interior Connection Area 1 Line Conductor Connections 2 Ground Connection 3 Remote Control Interface 12 2014 Siemens Industry Inc 813776 SIEMENS 2 6 Device States EVSE s do not have the capability to determine whether your car has been charged or not refer to car manual for indication of car battery status De
2. Oo ________ ____________ ___ 14 231 BUNG do ee 14 ERES COCO A ana 14 Cord and plug installation UNIVERSAL 5 15 3 4 Hard wired installation UNIVERSAL HARDWIRED 18 3 5 Amperage Adjustment 20 3 6 Remote Control Interface iii 21 SCOR 23 4 FOV OU 23 2 L pu 23 D 23 4 4 Management iii 24 A im ru unu m dd ee ec 25 4 6 Halo 25 4 7 Remote Control Interface 26 D CORS MODS RO _______________ 28 ARC u u uuu a 28 5 2 OPECi Emors and uuu ull menace 28 e o AE Gs AEE 29 Section 7 Wiring Diagrams 32 3 2014 Siemens Industry Inc 813776 SIEMENS 4 2014 Siemens Industry Inc 813776 SIEMENS 1 Important Safety Information 1 1 Read this First This manual contains important instructions for use during installation and maintenance of the Siemens VersiCharge electric vehicle charging station 1 2 Symbol Legend To reduce the risk of electrical s
3. Flush mount installations GROUND only meaning the receptacle is 7 WALL STUD even with wall in which it is installed Locate a stud within the i ORIENTATION wall to attach the mounting DETAIL bracket RECEPTACLE BDX o For concrete or masonry MUST BE MOUNTED LEFT SIDE FOR walls install appropriate BRACKET anchors Verify that the stud 6 50 surrounding RECEPTACLE materials can handle the 20 lbs load of the VersiCharge Ensure that receptacle can be flush mount installed to the left side of the mounting bracket o Receptacle should be installed prior to mounting the VersiCharge to the wall REAR FED HIDDEN PLUG MOUNTING o Verify local code with respect to installation height 2011 specifies Indoor Article 625 29B states installation 18 48 inches above ground level Wire a standard NEMA 6 above it is NEMA 6 50 receptacle using appropriate wire Using 7 16 inch socket head and drill attach the Mounting Bracket to the wall using two lag screws provided Verify that lag screws are going into the stud 17 2014 Siemens Industry Inc 813776 SIEMENS To hang unit onto the mounting bracket place bottom mounting tab into corresponding slot in mounting bracket Plug cord into receptacle Rotate the unit towards the wall so that the hook on the unit goes over the top
4. mounting bracket Secure VersiCharge to wall and mounting bracket 3 4 Hard wired installation UNIVERSAL HARDWIRED UNITS NOTE UNIVERSAL UNITS may be installed outdoors while HARDWIRED UNITS cannot be installed outside This section describes the hard wired installation for the hardwired units but also includes the step of removing the cord and plug assembly in case the universal VersiCharge units need to be hard wired during installation Removing the Cord and Plug Assembly only required for UNIVERSAL UNITS Open hinged cover by loosening four cover Phillips closure screws Remove barrier by removing the two securing screws Remove the cord and plug assembly from the conductor opening 18 2014 Siemens Industry Inc 813776 SIEMENS o Disconnect the attachment plug wires from the terminal block by loosening screws in position 1 2 and 3 Do not adjust the two screws on top of the terminal block unit These are for factory use only o Disconnect and remove strain relief and entire cord and plug assembly Continue with directions in Wiring Steps for Hard Wired Installation starting at Proper strain relief is required for conduit connection Wiring Steps for Hard Wired Installation Open hinged cover by loosening four cover Phillips closure screws Remove barrier by removing the two securing screws Hazardous voltage Will cause death or serious injury Turn off Power be
5. S DN J 43 1538232 NOLLVTIVLSNI 3HIM Wues x pue 169 OL Ee lt 4 s 1 sur 3J Z _ Z SM a dp ZS 2 PAPE wa s puodo SHAU SOLS peog LUE Jaaa 19 NICOLE TA SEIS Sus A 813776 2014 Siemens Industry Inc 33
6. disassembled or modified without the prior written authorization of Siemens THE LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY SIEMENS AND WHERE PERMITTED BY LAW IS MADE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED STATUTORY OR OTHERWISE INCLUDING WITHOUT LIMITATION WARRANTIES OF TITLE QUALITY MERCHANTABILITY FITNESS FOR PARTICULAR PURPOSE OR NON INFRINGEMENT OR WARRANTIES AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN MANUALS OR OTHER DOCUMENTATION IN NO EVENT WILL SIEMENS BE LIABLE FOR ANY SPECIAL DIRECT INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSSES COSTS OR EXPENSES HOWEVER ARISING WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT LIMITATION ANY ECONOMIC LOSSES OF ANY KIND ANY LOSS OR DAMAGE TO PROPERTY OR ANY PERSONAL INJURY To the extent any implied warranties are required under applicable law to apply to the Siemens VersiCharge EVSE such implied warranties shall to the extent permitted by applicable law be limited in duration to the Warranty Period In states and provinces which do not allow limitations or exclusions on implied warranties or on the duration of an implied warranty or on the limitation or exclusion of incidental or consequential damages the above limitation s or 30 2014 Siemens Industry Inc 813776 SIEMENS exclusion s may not apply This Limited Warranty gives the customer specific legal rights The custome
7. park an EV walk past the device open nearby doors etc without obstruction lf the installation location is not already wired for installation installation of the VersiCharge unit should be planned with an electrician and then the electrician should bring in the electricity according to those guidelines should not be exposed to flammable vapors This equipment should be installed at least 18 inches above floor or ground level Use extreme caution and follow instructions carefully Z YNA Explosion hazard This equipment has arcing or sparking parts that Ss 3 3 Cord and plug installation UNIVERSAL UNITS The standard VersiCharge unit UNIVERSAL UNIT arrives factory configured for rear fed and bottom fed cord and plug installations Do not remove the cord as it should not be reinstalled once removed outdoor rated receptacle and enclosure when installed outdoors Installing outdoors without properly rated outdoor receptacles and enclosures will violate listings and void the device warranty Outdoor cord and plug installations must be bottom fed only WARNING Due to risk of moisture cord and plug installations require a NEMA Bottom fed Cord and Plug Installation Mounting Measure the plug in cord of the unit first since the mounting bracket and the receptacle need to be located within this distance of each other Locate a stud within the wall to attach the mounting bracket o For concrete or masonry wall
8. power connections to ensure that adequate contact pressure is applied See the installation section of this manual for additional details A device provided with a wire connector for field installed wiring shall be provided with instructions specifying that the connector provided shall be used in making the field connection When installing this device in the hard wired configuration power connections shall be made at line terminals with 14 5in lbs torque An insulated grounding conductor that is identical in size insulation material and thickness to the grounded and ungrounded branch circuit supply conductors except that it is green with or without one or more yellow stripes shall be installed as part of the branch circuit that supplies the device or system The grounding conductor shall be grounded to earth at the service equipment or when supplied by a separately derived system at the supply transformer Do not attempt to operate this device if the ambient temperature is greater than 50C 122F Use 6 8 AWG 75C copper wire to connect to supply circuit CAUTION To reduce the risk of fire connect only to a circuit provided with 40 amperes maximum branch circuit overcurrent protection in accordance with the ANSI NFPA 70 National Electrical Code 1 7 Code and Standard References This device has been designated to meet the requirements in section 626 of the National Electric Code NEC UL Listing with Listing Number Siemens VersiCha
9. your local utility prior to beginning work to understand local requirements Qualified person Because of the inherent dangers of electricity only a qualified person should install maintain service or replace electrical wiring and connected equipment For the purpose of this manual a qualified person is one who is familiar with the installation construction of operation of the equipment and the hazards involved In addition this person should meet the definition of a qualified person pursuant to the National Electrical Code NEC Failure to comply with the recommendation of having a qualified person install the unit when electrical work is required may void the warranty provided with this device Weatherproof seals HARDWIRED UNITS are for indoor use only These devices have no gaskets or seals UNIVERSAL UNITS may be used indoors and outdoors objects entering into the device These can cause damage to electrical components and WARNING Failure to properly seat seals can result in water debris and other foreign prevent the device from functioning properly 1 6 Instructions Pertaining to a Risk of Fire or Electric Shock PIN WARNING When using electric products basic precautions should always be followed including the following This manual contains important instructions for Universal and Hardwired Units that shall be followed during installation operation and maintenance of the unit Read all of the instructions b
10. Changes or modifications not expressly approved by the party responsible for compliance may void the user s authority to operate the equipment and the warranty on the product Other Information Product information is subject to change without notice All trademarks are recognized as the property of their respective owners For Siemens VersiCharge Warranty Terms and Conditions see the Appendix on page 29 of this manual 2014 Siemens Industry Inc All rights reserved 2 2014 Siemens Industry Inc 813776 SIEMENS Table of Contents 1 Important Safety Information iii 5 Rea HS Ji nn u nuna ____ ________ 5 1 2 Symbol Legend ii 5 e s la ADC TS 5 TEDO UNIOR __________ 6 1 5 Safety Instructions General and Specific 6 1 6 Instructions Pertaining to a Risk of Fire or Electric 6 1 7 Code and Standard References iii 7 2 Device OU Ei ein 9 OO OR _ __ eee 9 4 2 LED MOI AIO RSS 9 2 3 Mounting Bracket Receptacle Included 10 OO 11 2 5 Interior Connection Area ii 12 PO DENCE TS 13
11. SIEMENS Installation and Operations Manual Siemens SIEMENS 1 2014 Siemens Industry Inc 813776 SIEMENS Contact Information Siemens Industry Inc Infrastructure amp Cities Sector Low and Medium Voltage 5400 Triangle Parkway Norcross GA 30092 1 800 241 4453 www usa siemens com versicharge info us siemens com FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver 15 connected e Consult the dealer or an experienced radio TV technician for help
12. after the VersiCharge re enters the Charging state the VersiCharge will return to the Fault state and remain in that state until it is manually reset During this time the Fault indicator will be illuminated in red the 4 Hour Delay indicator will be illuminated and the Halo on the unit will be illuminated in a constant red color o To reset the device press the Pause button which will take the device to the Pause state o Pressing the Pause button again will move the VersiCharge to the Ready to Charge state and if a charge is required the VersiCharge will automatically begin charging and move to the Charging state then turn it back on NOTE Some cars may delay the command to start charging again when coming out of Pause state Please refer to user manual of the EV if this is reset the device you can turn the circuit breaker feeding the device off happening on your unit If the device continues to experience immediate faults contact a qualified person for assistance Delay timer LEDs in combination with fault LEDs give more information on fault type Please call customer support for more details 4 4 Cord Management The VersiCharge has a built in cord management system 24 When not in use the connector cord should be looped over the top of the VersiCharge unit to prevent accidental damage The connector should be plugged into the co
13. ee section 4 7 for more details on this interface 22 2014 Siemens Industry Inc 813776 SIEMENS Section 4 Operation 4 1 Overview The VersiCharge EV Charging Stations incorporate industry accepted operating standards for EV charging These include the operation and communication protocols between the VersiCharge and the EV as well as the required safety features This section explains in detail the steps of operation 4 2 Typical Operation The VersiCharge is primarily a plug and play device Descriptions of various device states can be found in Section 2 6 o Verify that the VersiCharge is in the Power Available state by ensuring that the Power Available indicator is illuminated o Remove the connector from the connector holster by pressing the button on the connector handle and pulling the handle away from the VersiCharge holster o Plug the connector into the corresponding receiver on the EV Feel fora positive connection with a click connection can cause damage to the EV and or the VersiCharge If the connection between the receiver and the connector shows any resistance inspect the pins in each and if damage is found call a qualified service person WARNING Do not force the connector into the receiver on the EV Forcing the o If the EV does not require a charge the VersiCharge will go into the Ready to Charge state o If the EV does require a charge the VersiCharge will automatical
14. efore using this product Failure to follow these instructions may lead to death serious injury or property damage I National Electrical Code and NEC are Registered Trademarks of the National Fire Protection Association NFPA 2014 Siemens Industry Inc 813776 SIEMENS Any electrical wiring required to install this device shall conform to applicable codes and standards 70 A qualified electrician is recommended to perform these tasks To reduce the risk of electric shock never service install or uninstall this device from service while energized This equipment has arcing or sparking parts that should not be exposed to flammable vapors This equipment should be located at least 18 inches above the floor This device is equipped with an auto reset feature this device is connected to a vehicle at the time that power is restored following an outage charging may automatically resume this device is connected to a vehicle and a ground fault trip occurs charging may automatically resume after a delay period This device should be supervised when used around children Do not put fingers into the electric vehicle connector Do not use this product if the flexible power cord or EV cable is frayed has broken insulation or any other signs of damage Do not use this product if the enclosure or the EV connector is broken cracked open or shows any other indication of damage A torque driver shall be used to make
15. etting 0 MIN MAX Current A 6 75 15 225 30 _ Power kW 1 44 Circuit Requirements Circuit must be sized for the max ampere requirement Do not de rate breakers or conductors based on amperage adjustment 3 6 Remote Control Interface The Siemens VersiCharge has a Remote Control Interface that allows charging to be controlled by an external device This interface could be used to respond to a demand response event from a utility Installing higher voltage on this interface can cause damage to unit preventing it WARNING Remote Control Interface should be low voltage control wiring from functioning properly Do not hook up 120 240 V to these connections 21 2014 Siemens Industry Inc 813776 SIEMENS Control Switch input is dry contact input from an external source Status Output indicates the charging Status of the VersiCharge The Remote Control Interface is located inside the unit so to connect a device the unit has to be opened by taking the following steps Open hinged cover by loosening four cover Phillips closure screws Remove barrier by removing the two securing screws Remove connector to run wire Route control wiring with proper protection and strain relief through the low voltage wire opening Do not route the wiring along with any high voltage connections o Install external control source according to the instructions provided with that device Note S
16. fore attempt to open enclosure user serviceable parts inside Refer servicing to qualified service worki Ng nside personne Turn off power supplying this device before working inside 749 Explosion hazard This equipment has arcing or sparking parts that should not be exposed to flammable vapors Use extreme caution and follow instructions WZ 5 2014 Siemens Industry Inc 813776 SIEMENS gt Indicates connection point for Ground conductor 1 4 Definitions The term EV used in this manual refers to an electric vehicle The term AC used in this manual refers to alternating current The term Universal unit refers to any VersiCharge with a plug and chord assembly attached i e part numbers VC30XXXU Indoor Outdoor Use The term Hardwired unit refers to any VersiCharge which is factory configured for hardwired installation only part numbers VC30XXXHW Indoor Use only 1 5 Safety Instructions General and Specific Wy Hazardous voltage Will cause death or serious injury off Power supplying this equipment before working inside Read this Installation and Operations Manual in its entirety prior to installing maintaining servicing or replacing a Siemens VersiCharge EV Charging System Permits Be aware that many areas require special permits and or utility approvals to install EV charging equipment Contact your local electrical inspector s office and
17. fore working on this equipment by turning the circuit breaker to which this circuit is wired to the position Chose appropriate conduit hub depending on whether your installation is inside or outside Outdoor installations must be completed with a water tight conduit hub We recommend flexible conduit for easier use during installation Locate a stud within the wall to attach the mounting bracket and receptacle For concrete or masonry walls install appropriate anchors Verify that the stud or anchor and surrounding materials can handle the 20 los load of the VersiCharge Verify local code with respect to installation height o Installation height is regulated by NEC however this can vary based on local jurisdiction o NEC 2011 specifies Indoor Article 625 29B installation 18 48 inches above ground level Outdoor Article 625 30B installation 24 48 inches above ground level 19 2014 Siemens Industry Inc 813776 SIEMENS 20 Using 7 16 inch socket head and drill attach the Mounting Bracket to the wall using the two lag screws ensuring that the cutout lines up with the conduit and that the two lag screws are going into the stud Route conduit to the opening of the unit and terminate appropriately Route conductors with proper strain relief into the VersiCharge from the conductor opening o Pull 3 6 inches of slack through the conductor opening Place bottom mount
18. hock and to ensure the safe installation and operation of the Siemens VersiCharge the following safety symbols appear throughout this document to indicate dangerous conditions and important safety instructions working on this equipment This indicates a situation where the present voltage could Cause injury or death Extreme caution is required when servicing or installing the equipment referenced 2 79 0 Hazardous voltage Will cause death or serious injury Turn off Power before 99 Explosion hazard This equipment has arcing or sparking parts that should not be exposed to flammable vapors Use extreme caution and follow instructions carefully hazard or cause equipment malfunction Use extreme caution and follow instructions WARNING This indicates a situation where failure to follow instructions may be a safety PIN carefully NOTE This indicates information particularly important for optimal system operation Follow instructions closely gt Indicates connection point Ground conductor 1 3 Product Labels The following symbols appear on the product label and are described here DANGER This label indicates the risk of hazardous Hazardous voltage voltage and electric shock which will cause Will cause death serious injury substantial property damage death serious injury or substantial damage Risk of electric shock Do not remove cover or Turn off power supplying this device be
19. ing tab into corresponding slot in mounting bracket Secure VersiCharge to wall and mounting bracket Wire conductors copper only into device L1 L2 and Ground from connected conduit Using torque screw driver torque all lugs to 14 5 Ib in Replace barrier and secure with the two screws which were removed in the beginning Rotate the unit towards the wall so that the hook on the unit goes over the top mounting bracket Replace hinged cover securing with four Phillips head screws secure VersiCharge to wall and mounting bracket 3 5 Amperage Adjustment The Siemens VersiCharge has the option to set the maximum amperage power that can be delievered to the car using the Amperage adjustment switch Note that Versicharge cannot control the power draw to the EV it can only communicate the current capacity of the device to the EV Note The EV controls the power draw the VersiCharge only communicates the maximum available power to EV Dial Settings Amperage adjustment dial is for use by a qualified technician only Purpose of the amperage adjustment dial is to limit the max power that can be delivered by the charging station The dial has 10 settings o 0 4 are for amperage adjustments 2014 Siemens Industry Inc 813776 SIEMENS o Settings 5 9 are for factory use only These settings will result in a fault if used Verify that the VersiCharge is disconnected from power when changing the amperage adjustment dial S
20. ly switch to the Charging state An audible click is present when the VersiCharge goes into and out of the Charging state o Once the charge is complete or the EV sends a signal to stop charging the VersiCharge will automatically return to the Ready to Charge state 4 3 Faults A fault is indicated by a solid red halo a blinking red halo and or the fault LED being illuminated In of these conditions please press the button twice to reset the device If the condition persists please turn the circuit breaker feeding the device off then turn it back on If the condition still persists please contact customer support at 1 800 241 4453 23 2014 Siemens Industry Inc 813776 SIEMENS The VersiCharge will automatically disconnect power in the event of a fault lf a fault occurs during charging the VersiCharge will disconnect power from the EV with an audible click and change to the Fault state The VersiCharge will automatically self recover when all faults clear with the exception of grounding faults For grounding faults after 15 minutes the VersiCharge will attempt to continue charging and if no faults are present will return to the Charging state During this 15 minute delay the Fault indicator on the unit will blink the 2 Hour Delay indicator is illuminated and the Halo on the unit will blink red simultaneously lf a fault is still present immediately
21. mark or serial number of such VersiCharge EVSE have been defaced altered or removed The Limited Warranty does not cover costs related to the removal installation or troubleshooting of the customer s electrical systems The Limited Warranty does not extend beyond the original cost of the Siemens VersiCharge EVSE During the Warranty Period Siemens will at its option repair or replace the Defective Product free of charge provided that Siemens through inspection establishes the existence of a defect that is covered by the Limited Warranty siemens will at its option use new and or reconditioned parts in repairing or replacing the Defective Product Siemens reserves the right to use parts or products of original or improved design in the repair or replacement of Defective Product If Siemens repairs or replaces a Defective Product the Limited Warranty continues on the repaired or replacement product for the remainder of the original Warranty Period or ninety 90 days from the date of Siemens s return shipment of the repaired or replacement product whichever is later The Limited Warranty covers both parts and labor necessary to repair the Defective Product but does not include labor costs related to un installing the Defective Product or re installing the repaired or replacement product The Limited Warranty also covers the costs of shipping repaired or replacement 29 2014 Siemens Industry Inc 813776 SIEMENS product from Siemen
22. nnector holster on the front of the VersiCharge to prevent accidental damage 2014 Siemens Industry Inc 813776 SIEMENS While in use the cord can be unwrapped loop by loop to allow sufficient length of cord to be unwound to reach the EV receiver WARNING Failure to properly protect the connector and the cord could result in PIN damaged components which could prevent the VersiCharge from functioning properly or create a hazardous situation 4 5 Delay The VersiCharge has built in delay timer to allow users to select the time that they would like for their EV to charge The delay timer will prevent the VersiCharge from entering the Charging state for the selected length of time 2 4 6 8 hours From either the Charging state or the Ready to Charge state press the Delay Timer button o Pressing the button once will delay charging to 2 hours o Pressing the button twice will delay charging to 4 hours o Pressing the button three times will delay charging to 6 hours o Pressing the button four times will delay charging to 8 hours o Pressing the button a fifth time will deactivate the timer and return the VersiCharge to the ready to Charge state and if the EV requires a charge to the Charging state Every two hours the next hour Delay indicator will turn off so you can tell how much delay time is remaining by looking at the remaining illuminated Hour Delay indicat
23. ommended when installing or servicing any electrical equipment Charging Circuit Interrupting Device CCID The Siemens VersiCharge line of EV Charging Systems includes a Charging Circuit Interrupting Device CCID The CCID is required by UL Standard 2231 and is designed to detect grounding faults within the system and disconnect power from the downstream conductors when a fault is detected Arcing component in contactor Siemens VersiCharge EV Charging Systems include a contactor that when opened or closed will cause a short duration arc The contactor is enclosed in an appropriate electrical enclosure but caution if this arc occurs in the presence of flammable vapors the vapors could ignite creating an explosion Store flammable vapors away from all electrical equipment and should vapors be present allow sufficient time for ventilation before operating this equipment a PME Explosion hazard This equipment has arcing or sparking parts that should Ya not be exposed to flammable vapors This equipment should be installed at least 18 inches above floor or ground level Use extreme caution and follow instructions carefully 8 2014 Siemens Industry Inc 813776 SIEMENS 2 Device Layout 2 1 Exterior Front 1 Pause Button 1 2 Delay Timer Button 3 Connector 4 Connector Holster 5 Halo Indicator 6 Closure Screws 7 Hinges 2 2 Exterior LED Indicators 1 Pause 2 Charging 3 Power Available
24. ors o For example If only the 2 Hour Delay indicator is illuminated the delay has less than 2 hours remaining o When the delay timer runs out the VersiCharge unit will automatically return to ready to Charge state and if the EV requires a charge to the Charging state 4 6 Halo Operation Halo States Halo indicator on VersiCharge indicates the status of charging session 25 2014 Siemens Industry Inc 813776 SIEMENS State Name Description Halo Status Indicator Power Available 240V or 208V Power Present Ready to Charge EV detected waiting for charging Green Solid command from EV Charging Charging EV Green Fading in and out Delay Operation awaiting delay timer Off Remote System is controlled via remote control Off interface Halo Deactvation The Halo indicator on the versiCharge can be deactivated to marginally lower power consumption of your device during normal operation This will prevent the Halo from illuminating in all states except the Fault state de re activate the Halo o Remove the connector from the EV and place in the connector holster o Verify that the VersiCharge is in the Power Available state by ensuring that only the Power Available indicator is illuminated o Press and hold both the Pause and the Delay Timer buttons for 5 seconds The Halo will blink green three times and then fade out to off 4 7 Remote Control Inte
25. r may have other rights that vary from state to state or province to province 31 2014 Siemens Industry Inc 813776 SIEMENS iagrams D iring W Section 7 dl cer L SL F 2 5 3220 11 19 38 021 Es du 1 7 gt 9 5 gt CH LI JURA HADEV AT WFD DIE Je 14 SHIN M 1u HNP ATA SVS 3H1 BRAS 1 22 9190 T13A0G33447 NOI LVT1V1SNI 9NId ONY 0HO9 OLUN JUS PROT 3105 0 EWEN PURGIS Sy nie 09 9 ewe z Sul1 2 H JES OL L lt A LI z AQUE ZAL S H op z paysa pen a gt LA perg 0 ef DOOKUEDA tl t lade 813776 2014 Siemens Industry Inc 32 SIEMENS 3543 4168 7HT S1eL5274 WYd9VI IO ONld M cats ee ONCE SS HHLA SHAS L y 2190
26. rface The Siemens VersiCharge has a Remote Control Interface that allows charging to be controlled by an external device Examples include demand response switches building automation systems digital sensors etc To wire a digital input into the dry contact in the connection area located inside of the VersiCharge please refer to the installation section 3 6 of this manual 26 2014 Siemens Industry Inc 813776 SIEMENS When the external contact is closed the alternate input will control the VersiCharge preventing it from entering the Charging state The status output is a switch that indicates charging status When the contacts are closed the unit is in charging state 27 2014 Siemens Industry Inc 813776 SIEMENS Section 5 Troubleshooting 5 1 General Settings Some of the errors that occur are not caused by the VersiCharge but by the EV compatibility or by settings which are turned on in the EV itself the unit is going into fault please check the settings in the EV to ensure that these are not causing the VersiCharge to stop charging Many EVs have a setting for time of charge for example in which the user defines a preference of charging only in certain hours of the day night Settings such as these will override all commands within the VersiCharge for safety reasons and will thus stop charging your EV Adjusting the settings in the car would be the suggested action to take in order to be compatible
27. rge Devices are listed in UL file E348556 Complies with the following UL Standards 2594 2231 1 2231 2 EV interface compliant to SAE J 1772 Level Il This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by 2014 Siemens Industry Inc 813776 SIEMENS turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna o Increase the separation between the equipment and receiver o Connect the equipment into an outlet on a circuit different from that to which the receiver is connected o Consult the dealer or an experienced radio TV technician for help Personal Protection Equipment Use of proper personal protection equipment including but not limited to eye protection shock protection gloves and other appropriate protection is rec
28. s install appropriate anchors o Verify that the stud or anchor and surrounding materials can handle the 20 lbs load of the VersiCharge 15 2014 Siemens Industry Inc 813776 SIEMENS Receptacle will be located below VersiCharge mounting bracket either to the left or ORIENTATION the right of the stud to which DETAIL the mounting bracket will be attached Verify receptacle location complies with local code requirements 2011 specifies RECEPTACLE BOX MAY BE MOUNTED EITHER Indoor NEC Article N 625 29B installation 18 48 inches above ground level 8 p RECEPTACLE TO CENTER o Verify local code with RECEPTACLE respect to installation height RECEPTACLE Wire a standard NEMA 6 50 receptacle using appropriate wire FLOOR Using 7 16 inch socket head and drill attach the mounting bracket to the wall using two lag screws provided Verify that lag screws are going into the stud VersiCharge on the Mounting Bracket by first hooking the bottom of the unit into the mounting slot and then hooking the top into the mounting tab Secure VersiCharge to wall and mounting bracket using provided screws Plug the VersiCharge into the receptacle 16 2014 Siemens Industry Inc 813776 SIEMENS Rear fed Cord and Plug Installation Mounting N 4
29. s via a non expedited freight carrier selected by Siemens to locations within the United States including Alaska and Hawaii and Canada but not to other locations outside the United States or Canada The Limited Warranty does not cover shipping damage or damage resulting from mishandling by the freight carrier Any such damage is the responsibility of the freight carrier To obtain repair or replacement service under this Limited Warranty the customer must comply with the following policy and procedure Defective Product must be returned with Return Merchandise Authorization Number RMA which customer must request from Siemens e RMA request must include the following information Proof of purchase of the Defective Product in the form of 1 the dated purchase receipt from the original purchase of the product at point of sale to the end user or 2 the dated dealer invoice or purchase receipt showing original equipment manufacturer OEM status or 3 the dated invoice or purchase receipt showing the product exchanged under warranty Model number of the Defective Product o Serial number of the Defective Product o Detailed description of the defect o Shipping address for return of the repaired or replacement product e All Defective Product authorized for return must be returned in the original shipping container or other packaging that is equally protective of the product e The returned Defective Product must not have been
30. scription Indicator s Halo Status Indicator Power 240V or 208V Power Present Power Available Off Available Ready to EV detected waiting for Power Available Ready Green Solid Charge charging command from EV Charging Charging EV Power Available and Green Fading Charging in and out Operation paused Power Available and Pause Delay Operation awaiting delay timer Power Available and Hour s Off Timer Delay Remote System is controlled via Power Available and Remote Off remote control interface Control Lock Some EV s may initiate a delay of charge when exiting out of the Pause state before the EV starts telling the VersiCharge to start charging again Please refer to the user manual for the EV for further information Further combinations of indicators on the unit are described in the Fault code section 4 3 13 2014 Siemens Industry Inc 813776 SIEMENS Section 3 Installation 3 1 Building Survey Available voltage current and frequency VersiCharge charging stations can draw up to at 240 50 60 Hz 7 2kW of power The complete electrical structure of the building must be adequately sized to handle the entire building energy load under peak conditions as well as the charging station load under operation Checking for adequate power includes all the connections from the utility through the entire circuit structure
31. stand normal operating conditions when used in compliance with the Siemens Installation and Operations Manual supplied with system as originally shipped by Siemens The Siemens limited warranty Limited Warranty covers defects in workmanship and materials of the VersiCharge EVSE Defective Product for a period of three 3 years the Warranty Period from the date of original purchase of such VersiCharge EVSE The Limited Warranty does not apply to and Siemens will not be responsible for any defect in or damage to any Siemens VersiCharge EVSE 1 that has been misused neglected tampered with altered or otherwise damaged either internally or externally 2 that has been improperly installed operated handled or used including use under conditions for which the product was not designed use in an unsuitable environment or use in a manner contrary to the Siemens Installation and Operations Manual or applicable laws or regulations 3 that has been subjected to fire water generalized corrosion biological infestations acts of God or input voltage that creates operating conditions beyond the maximum or minimum limits listed in the Siemens VersiCharge EVSE specifications including high input voltage from generators or lightning strikes 4 that has been Subjected to incidental or consequential damage caused by defects of other components of the electrical system or 5 if the original identification markings including trade
32. to the branch circuit position and connected wiring Utility connection and transformer capacity check with utility service provider to ensure enough power is available for the building and the VersiCharge under full loading Available breaker positions and amperage Verify the panel has an open position for a two pole breaker Verify that the additional 30 A draw from the VersiCharge will not exceed the total loading for the Main Breaker of the structure Breaker selection A 2 pole 40 A dedicated branch breaker is required for both cord and plug installation and hard wired installations Siemens Part numbers Q240 plug in type B240 bolt on type The VersiCharge must be wired on a dedicated circuit with no other loads wired on that circuit 3 2 Site Selection 2 NOTE To ensure optimal functionality we dont recommend installing the 4 VersiCharge unit in the direct sunlight Z NOTE UNIVERSAL UNITS may be installed in environments in which NEMA 3R ratings are required while HARDWIRED UNITS may only be installed in environments where NEMA 1 ratings are required Accessibility 14 When selecting a mounting site ensure that the connector can reach the EV before starting installation 2014 Siemens Industry Inc 813776 SIEMENS The VersiCharge will mount on the surface of the wall protruding at least 15 inches and a location for installation should be chosen where there is sufficient to
33. with the VersiCharge Nuisance fault As a leader in electrical technology Siemens has made the decision to install 5 mA grounding protection in all VersiCharge devices This is the same level of protection that is required in kitchens and bathrooms of residential dwellings Some other manufacturers EVSE and Auto manufacturers have selected 20 mA protection levels Because Siemens units measure to a more sensitive level occasional charging interruption may occur under certain circumstances See section 4 3 for reset instructions 5 2 Specific Errors and Actions 4 28 The VersiCharge has been designed to self indicate which type of fault has fault is indicated by a solid red halo blinking red halo and or the fault LED being illuminated In any of these conditions please press the Pause button twice to reset the device If the condition persists please turn the circuit breaker feeding the device off then turn it back on If the condition still persists please contact customer support at 1 800 241 4453 WARNING Before taking any of the actions which suggest opening the unit for adjustment turn off the power supply the VersiCharge 2014 Siemens Industry Inc 813776 SIEMENS Section 6 Warranty Limited Warranty siemens Industry Inc Siemens has developed a highly reliable EV Supply Equipment EVSE branded as VersiCharge VersiCharge EVSE that is designed to with
Download Pdf Manuals
Related Search
Related Contents
Multiplex Technology CHANNEL PLUS 3515 User's Manual OM, Rider ProFlex 18, 2001-02 Elegant Home Fashions HD21720 Instructions / Assembly Omega OMG-COMM8-PCI Computer Accessories User Manual Aria - Aria elite - Aria USER MANUAL - SLS-Sinusleistungssteller! TurningPoint® AnyWhere Benutzerhandbuch CityPOINTS - SMARTech - Georgia Institute of Technology Copyright © All rights reserved.