image

Contents

1. Be Ve H Hi 7 Hi 2 Hi f IN La jA ps pr i p O AD LA IN YY 0 Lafi Ir I ail ft ut afl di H ll J WP Q I Hi di Hi Me p p UP HOW TO USE CD BEFORE USING YOUR AIR CONDITIONER PREPARING FOR OPERA TION UNPACKING THE AIR CONDITIONER Refer to the Installation Instructions included in Remove and store packing materials for reuse this manual before using the air conditioner Remove any shipping tape before using the Once the air conditioner has been properly air conditioner If the tape leaves behind any assembled and installed adhesive rub a small amount of liquid dish Plug the power cord into its own dedicated soap onto it and wipe with a damp cloth DO properly grounded outlet Do not plug NOT use sharp instruments alcohol thinners l l or abrasive cleaners to remove adhesive other appliances into the same outlet They could damage the finish it could overload the outlet and create a fire hazard Make sure the air conditioner and cord is positioned where it does not create a tripping hazard and will receive adequate ventilation Do not place it directly next to furniture or objects that could block the vent openings Make sure that any items that could be blown over or damaged by the airflow from the fan are out of the airflow path IMPORTANT Do no
2. Foam seal C Adhesive type shorter Vent Extension panel Panel if required TT ne _ Foam seal A Adhesive type IF Cut the foam seal A adhesive type amp 28 Insert the vent panel assembly including C adhesive type shorter to the proper extension panels if needed into the window length and attach it to the window sash Opening Extend the extension panels if and frame used Foam seal B Non adhesive type er Security Bracket 1 Cut the foam seal B Non adhesive type to A Install the security bracket with a type B the window width Stuff the foam seal B screw as shown if you need between the glass and the window to prevent air and insects from getting into the room 16 INSTALLATION INSTRUCTIONS INSTALLATION IN VERTICAL SLIDING WINDOWS B77 AZ Ce Co LF 5 D o m First insert to the vent panel fully and then slide for locking If you want fix the diffuser more firmly use the type C screw INSTALLATION INSTRUCTIONS CEB INSTALLATION IN CASEMENT STYLE WINDOWS NOTE The window installation kit can be used with casement windows between 18 and 50 tall Foam seal C Adhesive type shorter Extension panel if required i Cut the foam seal A adhesive type amp C adhesive type shorter to the proper extension panels if needed into the window length and attach it to the window sash and opening Exten
3. LG Life s Good HSITONA N o TONVWdS4 OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your air conditioner and retain it for future reference TYPE PORTABLE AIR CONDITIONER MODEL LP1014WNR INTRODUCTION IMPORTANT SAFETY INSTRUCTIONS Basic Safety Precautions 3 6 Electrical Safety sassen randen 6 THANK YOU D PARTS AND FEATURES Key Parts and Components 8 Congratulations on your purchase and welcome to the LG family GSD How TO USE y Before Using Your Air Conditioner 9 10 ia Control Panel and Remote 11 12 Your new LG Air Conditioner combines high efficiency operation CE INSTALLATION INSTRUCTIONS Preparing for Installation unaona 13 with portable convenience Selection of Installation Location 14 Attaching the Hose and Diffuser 14 If you follow the operating and care Window Vent Panel and Extensions 15 Installation in Vertical Sliding Windows 16 17 instructions in this manual your air Installation in Casement Style Windows 18 19 Srucuons minis manua y conditioner will provide you with CARE AND CLEANING many years of reliable service Water Drainage a buu nnsaran bean delend 20 Cleaning the Case e nn 21 Cleaning the Air Filter 21 Storing the Air C
4. F Fan circulates air but compressor does not run Use the FAN button to set the desired fan speed AN DRY Dry mode is used to remove humidity from the room without additional cooling Fan speed is pre set and cannot be adjusted FAN Adjusts the circulation fan speed between High and Low fan speed The selected fan speed will be shown through the indicator lights The function can be used in Cool and Fan modes When changing fan speeds there is a brief delay before the fan motor changes speed TIMER POWER Timer When the TIMER function is selected you can set the air conditioner to either automatically turn OFF or turn ON after a delay of up to 24 hours The display will show 0 Use the A W buttons to adjust the delay time from 1 to 24 hours in one hour increments To set an automatic off delay press the TIMER button while the air conditioner is running and use A the buttons to adjust the delay time air conditioner will automatically turn off after the set delay To set an automatic on delay press the TIMER button while the air conditioner is off and use A V the buttons to adjust the delay time The display will show the number of hours remaining until the unit is set to come on The air conditioner will automatically turn on after the set delay If you want to know how many hours you have setted press the TIMER button and then you can see the time through the LED display If you want to chang
5. of 72 F 20 CARE AND CLEANING D CLEANING THE CASE Wipe the case with a slightly damp cloth then wipe dry with a dry cloth or towel e To prevent damage to the finish do not use gasoline benzene thinner etc or any abrasive cleansers to clean the air conditioner they may damage the finish e Never pour water onto or into the air conditioner It could damage internal components and create a shock and fire hazard D CLEANING THE AIR FILTER The air filter should be cleaned every two weeks depending on indoor air quality more frequent cleaning may be needed A dirty air filter will decrease airflow and reduce efficiency Do not operate the air conditioner without the air filter in place Pull out the air filter by the handle Z 2 Use a vacuum cleaner to clean the filter If the filter is heavily soiled it can be washed in warm water using a 0 mild detergent a il Do not use harsh cleaners or very hot water IN ill 0 b ill Do not wash in a dishwasher S i IN ND ie ie SA I Q vy P G Allow the filter to dry completely before reinstalling 4 Reinsert the filter 21 CARE AND CLEANING STORING THE AIR CONDITIONER 22 If the air conditioner will not be used for an extened period of time CD To drain the water collection tank completely leave the bottom drain cap off long enou
6. D BEFORE CALLING FOR SERVICE self Possible Causes What To Do Code appears in the display FL The water collection tank Empty the water collection tank is full See the Care and Cleaning section E1 Short or open circuit in the Unplug the air conditioner and contact your indoor air thermistor authorized LG service center E2 Short or open circuit in the Unplug the air conditioner and contact your indoor pipe thermistor authorized LG service center E4 The coil sensor temperature After defrost the unit will re start is low the unit will stop and display E4 to defrost 24 WARRANTY LG PORTABLE AIR CONDITIONER LIMITED WARRANTY USA WHAT THIS WARRANTY COVERS LG Electronics U S A Inc LG warrants your LG Portable Air Conditioner product against defect in materials or workmanship under normal household use during the warranty period set forth below LG will at its option repair or replace the product This limited warranty is valid only to the original retail purchaser of the product is not assignable or transferrable to any subsequent purchaser or user and applies only when the product is purchased through an LG authorized dealer or distributor and used within the United States U S including U S Territories Note Replacement products and repair parts may be new or factory remanufactured and are warranted for the remaining portion of the original unit s warranty period or ninety 90 days whichever i
7. D KEY PARTS AND COMPONENTS AIR DISCHARGE The direction of air can be controlled wherever you want to cool by adjusting the horizontal louver The horizontal direction is adjusted by moving the lever to the left or right Touching the horizontal louvers adjusts the air direction up or down CONTROL PANEL AND DISPLAY Easy to read digital display shows the set temperature and indicator lights show the operating mode Simple push buttons make changing settings quick and easy SWIVELING CASTERS Swiveling casters allow you to move the air conditioner easily on most floor surfaces INTEGRATED HANDLES Y Integrated handles provide a convenient grip when lifting the air conditioner INFRARED REMOTE CONTROLLER The remote controller allows you to adjust the temperature and operate most functions of the air conditioner from across the room QG BOTTOM DRAIN PORT Before moving the air conditioner drain the internal water in the collection tank completely by using bottom drain port AIR FILTER HOSE AND DIFFUSER Use the diffuser and hose to connect the air conditioner to the window installation kit to vent exhaust air outside
8. NCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY NATURE INCLUDING AND WITHOUT LIMITATION TO LOST REVENUES OR PROFITS OR ANY OTHER DAMAGE WHETHER BASED IN CONTRACT TORT OR OTHERWISE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE EXCLUSION OR LIMITATION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE HOW TO OBTAIN WARRANTY SERVICE amp ADDITIONAL INFORMATION Call 1 800 243 0000 or visit our website at www lg com Mail to LG Customer Information Center ATTN CIC 201 James Record Road Huntsville AL 35824 LG Life s Good LG Customer Information Center 1 800 243 0000 Register your product Online LG ELECTRONICS INC 1000 Sylvan Ave Englewood Cliffs NJ 07632 www lgappliances com
9. RUCTIONS READ ALL INSTRUCTIONS BEFORE USE GDP ELECTRICAL SAFETY INTEGRATED CIRCUIT BREAKER PREFERRED GROUNDING METHOD For additional safety lt the power cord features an integrated circuit breaker Test and reset buttons are provided on the plug Case ground exists The circuit breaker Zi before use should be tested periodically by pressing the TEST button then the RESET button If the TEST button does not cause the circuit breaker to trip or if the RESET button will not stay engaged unplug the air conditioner immediately and contact your LG service technician Due to potential safety hazards the use of TEMPORARY GROUNDING an adapter plug is strongly discouraged METHOD For temporary connections use only a UL listed adapter Ensure that the large slot in the adapter is aligned with the large slot in the outlet To prevent damage to the adapter s ground terminal hold the adapter in place while Ensure proper i EN LA ground exists plugging in or unplugging the air conditioner before lise e Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall receptacle is grounded through the house wiring e Frequent connection and disconnection can damage the ground terminal on the adapter Never use a broken or damaged adapter SAVE THESE INSTRUCTIONS PARTS AND FEATURES CeeS C
10. STRUCTIONS gaa eee B Operation J XS Do not place heavy object Do not share the outlet with Take the power plug out if on the power cord and take other appliances necessary holding the head care so that the cord should of the plug and do not touch not be pressed it with wet hands e There is danger of fire or electric It will cause electric shock or fire Otherwise it may cause a fire shock or electrical shock y Aci c Do not place the power cord Do not allow water to run Use a soft cloth to clean Do near a heater into electric parts not use wax thinner or a strong detergent e t may cause fire and electric e It will cause failure of machine or The appearance of the air change color or develop surface Cm flaws Unplug the unit if strange Turn off the power and _ If water enters the product turn sounds odors or smoke breaker first when cleansing off the the power switch of the come from it the unit main body of appliance Contact service center after taking the power plug out from the socket e Otherwise it may cause fire and Since the fan rotates at high electric shock accident speed during operation it may cause injury Unplug the unit when not Do not operate or stop the Do not damage or use an using it for a long time unit by inserting or pulling unspecified power cord out the power plug e Prevent accidental startup and e It will cause electric shock or fire It will cause el
11. an not only improve cooling efficiency but also save energy for you Using the Upper Drain Port Dry Mode Only e This can be used when you need dehumidification in high humidity e Under the Cool or Fan mode there s no need of using the upper drain port During DRY dehumidifying mode remove the drain plug and the exhaust hose from the back of the unit Install a drain hose 12mm 1 2 inside diameter and place the open end of the hose at a suitable drain location or outdoors Using the Bottom Drain Port When the internal water collection tank is full the LED display will show FL and the air conditioner will turn off until the tank is emptied Unplug the air conditioner disconnect the exhaust hose from the back and move the air conditioner to a suitable drain location or outdoors You may also place a pan under the drain that will hold up to 2 pints of water e Remove the drain cap from the drain outlet Once the water collection tank is drained reinstall the drain cap making sure it is on securely e Place the air conditioner in the desired location reconnect the exhaust hose and plug in the air conditioner FL apperars in the display The water collection tank is full drain the tank and restart the air conditioner NOTES When turned on after being unplugged the air conditioner will automatically reset to COOL mode with a temperature setting
12. d the extension panels if frame used Foam seal B Non adhesive type Type B screw 1 Cut the foam seal B Non adhesive type to a Install the window security bracket with a the window height Stuff the foam seal B type B screw as shown between the glass and the window to prevent air and insects from getting into the room 18 INSTALLATION INSTRUCTIONS CD INSTALLATION IN CASEMENT STYLE WINDOWS then slide 3 Small gap Type C screw Tn a OW ab ae First insert to the vent panel fully and then slide for locking If you want fix the diffuser more firmly use the type C screw CARE AND CLEANING Your air conditioner is designed for year round For maximum efficiency it is recommended operation with only minimal cleaning and that you have the cooling coils inspected and maintenance cleaned annually Your local LG Authorized Service Center can provide this inspection VN WARN N G and cleaning service for a nominal fee e Unplug the air conditioner before cleaning or performing any maintenance or servicing e Be careful when cleaning coils or removing or reinstalling the filter the cooling fins are sharp Failure to follow the above precautions could result in electrical shock or personal injury EED WATER DRAINAGE This product has a self evaporative system The condensing water will be recycled to cool the condenser This c
13. e the set timer press the TIMER button and adjust the time when the number is flickering To cancel the Timer function press the TIMER button and adjust the number to 0 when the number is flickering then the function will be canceled in a few seconds Another better method is press the TIMER button and press this button again when the number is still flickering 11 HOW TO USE Gp CONTROL PANEL AND REMOTE Oo POWER Fan Cool Dry Tei TIMER TEMP DO l ii Be Operation of functions is the same when using the remote or the control panel unless otherwise stated NOTE The remote sensor is located under the LED display Point the remote anywhere at the sensor The remote may not work if the sensor is in bright light or if there is not a clear path between the remote and the sensor 4 Y TEMP TIMER SLEEP Increases the temperature by 1 F every 2 hours In COOL and DRY modes the A VW buttons to allow a more comforable adjustment for the user adjust the set temperature up to 86 F or down to 60 F in one degree increments The temperature O C F CELSIUS AND FAHRENHEIT can be switched between degrees Fahrenheit and EXCHANGE BUTTON degrees Celsius pressing A the button and V Nitenthe disclaveds ture is C oF button at the same time or pressing F C button en the displayed temperature is C or F you on the remote can press this button to switch to F or C When the TIMER f
14. ectric shock or fire the possibility of injury due to heat generation 5D VS IMPORTANT SAFETY INSTRUCTIONS Do not operate with wet Hold the plug by the head When gas leaks open the hands or in damp not the cable when taking window for ventilation before environment it out operating the unit e It will cause electric shock e It may cause electric shock and _ Otherwise it may cause damage explosion and a fire For inner cleaning contact an Authorized Service Center or a dealer Do not use harsh detergent that causes corrosion or damage on the unit Harsh detergent may also cause failure of product fire or electric shock A CAUTION B Operation Do not use this appliance for Do not block the inlet or Use a soft cloth to clean Do special purposes such as outlet of air flow not use wax thinner or a cooling pets foods precision strong detergent machinery or objects of art e It is an air conditioner not a e It may cause product failure e The appearance of the air precision refrigeration system conditioner may deteriorate 7 change color or develop surface flaws Do not step on the Always insert the filter Do not drink water drained indoor outdoor unit and do securely from air conditioner not put anything on it Clean it every two weeks e It may cause an injury through e Operation without filters will e It contains containments and will dropping of the unit or falling cause failu
15. er and rotate counter clockwise 14 INSTALLATION INSTRUCTIONS CB WINDOW VENT PANEL AND EXTENSIONS The window installation kit allows you to install the air conditioner in most vertical sliding windows 18 to 50 wide or casement style windows from 18 to 50 high pele irl wer stat te 27 34 Jy vt lc 35 50 v v vi d_ 1 Please check your window length and choose the fit panels from the above tabel 2 If your window length need more than 2 panels after adjust the length please use type A screw to fix them Panel B 9 Vi A Panel A For an 18 window opening use the window vent panel by itself Fig Panel C For window openings from 27 to 34 use the window vent panel Panel A and a extension panel Panel 7 Fig DR Panel C 17 Panel D 177 3 Extension Panels Panel A 18 1 Window Vent Panel Window Installation Kit includes 1 Window Vent Panel and 3 Extension Panels Panel B For window openings from 19 to 26 use the window vent panel Panel A and a extension panel Panel B Fig b For window openings from 35 to 50 use the window vent panel and two extension panels Panel C and Panel D Fig d INSTALLATION INSTRUCTIONS CED INSTALLATION IN VERTICAL SLIDING WINDOWS NOTE The window installation kit can be used with vertical sliding windows between 18 and 50 wide
16. gh to allow any residual water to drain out Once the tank is completely drained and no more water flows out reinstall the cap Remove and clean the filter allow it to dry completely then reinstall it O Remove the batteries from the remote 4 Store the air conditioner in a cool dry location away from direct sunlight extreme temperatures and excessive dust Before using the air conditioner again D Make sure the filter and drain cap are in place 2 Check the power cord to make sure it is in good condition with no cracks or damage O Place new batteries in the remote Install the air conditioner as described in the Installation Instructions TROUBLESHOOTING CED BEFORE CALLING FOR SERVICE Before you call for service review this list It may save you time and expense This list includes common occurrences that are not the result of a defect in workmanship or materials Self Possible Causes What To Do The air conditioner is Make sure the air conditioner plug is pushed alien unplugged completely into the outlet does not fate Sere tem ie Ne ae The fuse is blown circuit Check the house fuse circuit breaker box and Bide aU ene replace the fuse or reset the breaker Power failure If power failure occurs turn the mode control to Off When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload The current interrupter Press the RESET button located on t
17. he power device is tripped cord plug If the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician FL appears in the display The water collection tank is full Drain the tank and reset your settings Room temperature is less This is normal The air conditioner automatically than the set temperature shuts off when the room equals or is less than the set temperature Adjust the temperature setting if needed Air conditioner Airflow is restricted Make sure there are no curtains blinds or does not cool furniture blocking the front of the air conditioner as it should mummy ne The temp control may not In COOL model press the DECREASE Y pad be set correctly The air filter is dirty Clean the filter at least every 2 weeks See the Care and Cleaning section The room may have been When the air conditioner is first turned on you hot need to allow time for the room to cool down Air conditioner The cooling coils are iced Ice may block the air flow and obstruct the air freezing up over conditioner from properly cooling the room Set the mode control at High Fan or High Cool Air conditioner Area to be cooled is too Consult your dealer for the air conditioner runs too often large for the air conditioner capacity necessary to cool the desired area or too lon RR TT Senaren 9 Doors or windows are open Make sure doors and windows are closed 23 TROUBLESHOOTING CE
18. ld result in back injury or other injuries Panel B 9 EXHAUST COMPONENTS The following components are used for window venting Not all components are used for every installation Panel A 18 Panel C 17 Panel D 17 Flexible Venting Hose Diffuser 1 Window Vent Panel 3 Extension Panels Window Installation Kit includes 1 Window Vent Panel and 3 Extension Panels 2 Type A Foam Seals 1 Type B Foam Seal 2 Type C Foam Seals Adhesive Non adhesive Adhesive type Shorter pa o OD Op Om Security Bracket 2 Type A Screws 1 Type B Screw 1 Type C Screw 13 INSTALLATION INSTRUCTIONS D SELECTION OF INSTALLATION LOCATION GD Place the unit on a level floor For best performance allow at least 20 in of air space on all sides of the unit for good air circulation Place the unit near a window The hose and diffuser will be used to connect the air conditioner to the window installation kit to vent exhaust air outside 4 WARNING The length of the exhaust hose is specially designed according to the specification of this product Do not replace or extend it with your own private hose as this could cause malfunction ATTACHING THE HOSE AND DIFFUSER Insert the vent hose into the hole on the back of the air condition
19. om the batteries gets onto your skin or clothes wash it well with clean water Do not use the remote if the batteries have leaked e If you eat the liquid from the batteries brush your teeth and see doctor The chemicals in batteries could cause burns or other health hazards 10 HOW TO USE Gp CONTROL PANEL AND REMOTE a i TEMP Operation of functions is the same when using the remote or the control panel unless otherwise stated NOTE The remote sensor is located under the LED display Point the remote anywhere at the sensor The remote may not work if the sensor is in bright light or if there is not a clear path between the remote and the sensor Power Press the POWER button to turn the air conditioner ON or OFF Any control settings such as Cool Dry Fan and Fan Speed will be retained in memory when the power is off When turned on after being unplugged the air conditioner will automatically reset Any settings will need to be re entered mode Press this button to select the operating mode such as Cool Dry Dehumidify or Fan for the air conditioner And you can see the active mode through the indicator lights The default setting is Cool Press the MODE button to change to Dry Dehumidify press again to change to Fan and again to change to Cool Mode Features COOL Compressor runs and cools the room Use the A W andFAN buttons to set the desired temperature and circulation fan speed
20. onditioner 22 GERD TROUBLESHOOTING Before Calling for Service 23 24 CED WARRANTY Product Registration Information 25 IMPORTANT SAFETY INSTRUCTIONS hhh eee em BASIC SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage the following instructions must be followed B Incorrect operation due to ignoring instruction will cause harm or damage The seriousness is classified by the following indications A WARNING This symbol indicates the possibility of death or serious injury AX CAUTION This symbol indicates the possibility of injury or damage to properties only E Meanings of symbols used in this manual are as shown below K Be sure not to do Be sure to follow the instruction WARNING B Installation Don t use a power cord a Always plug into a grounded Do not modify or extend the plug or a loose socket which outlet power cord length is damaged e Otherwise it may cause a fire Otherwise it may cause a fire lt will cause electric shock or fire or electrical shock or electrical shock due to heat generation Do not disassemble or Be caution when unpacking Do not store flammables like modify products and installing gasoline benzene thinner etc near the air conditioner e t may cause failure and e Sharp edges may cause e It may cause explosion or fire electric shock Injury IMPORTANT SAFETY IN
21. pen box pipes restricted drain lines inadequate or interrupted discounted or refurbished product water supply or inadequate supply of air 10 Product where the original factory serial numbers have 4 Damage or failure caused by accidents pests and vermin been removed defaced or changed in any way lightning wind fire floods or acts of God 11 Repairs when product is used in other than normal and 5 Damage or failure resulting from misuse abuse improper usual household use e g rental commercial use installation repair or maintenance Improper repair offices or recreational facilities or contrary to the includes use of parts not approved or specified by LG instructions outlined in the owner s manual 6 Damage or failure caused by unauthorized modification or 12 The removal and reinstallation of the Product if it is alteration to the product installed in an inaccessible location 7 Damage or failure caused by incorrect electrical current voltage or plumbing codes THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESS OR IMPLIED INCLUDING AND WITHOUT LIMITATION TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW THIS WARRANTY IS LIMITED IN DURATION TO THE TERM PERIOD EXPRESSED ABOVE REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY FOR THE CUSTOMER NEITHER THE MANUFACTURER NOR ITS U S DISTRIBUTOR SHALL BE LIABLE FOR ANY I
22. re make you sick down IMPORTANT SAFETY INSTRUCTIONS lf the liquid from the battery gets onto your skin or clothers wash it well with clean water Do not use the remote if the battery has leaked e The chemicals in battery could cause burns or other health hazards ee GD ELECTRICAL SAFETY 4 WARNING Electrical Shock Hazard Failure to follow these instructions can result in death fire or electrical shock e This unit must be properly grounded e Do not under any circumstances cut or remove the ground prong e If you do not have a properly grounded outlet or if there is any doubt that the outlet is not properly grounded a qualified electrician should check the outlet and circuit and if necessary install a properly grounded outlet If you eat the liquid from the battery brush your teeth and see doctor Do not use the remote if the battery has leaked e The chemicals in battery could cause burns or other health hazards This air conditioner must be plugged into a grounded 60 Hz 120 VAC outlet protected by a 15 amp time delay fuse or circuit breaker This air conditioner must be installed in accordance with national wiring codes Do not alter or modify the plug or cord of this air conditioner If the power cord becomes worn or damaged the cord should only be replaced by a qualified service technician using genuine replacement parts Do not use an extension cord IMPORTANT SAFETY INST
23. s longer Please retain dated receipt or delivery ticket as evidence of the Date of Purchase for proof of warranty you may be required to submit a copy to LG or authorized representative WARRANTY PERIOD 1 year from the Date of Purchase Any internal functional Parts and Labor HOW SERVICE IS HANDLED In Home Service In home service will be provided during the warranty period subject to availability within the United States In home service may not be available in all areas To receive in home service the product must be unobstructed and accessible to service personnel If during in home service repair cannot be completed it may be necessary to remove repair and return the product If in home service is unavailable LG may elect at our option to provide for transportation of our choice to and from a LG authorized service center THIS LIMITED WARRANTY DOES NOT COVER 1 Service trips to deliver pick up or install the product or 8 Cosmetic damage including scratches dents chips or for instruction on product use other damage to the finish of the product unless such 2 Replacing house fuses or resetting of circuit breakers damage results from defects in materials or correction of house wiring or plumbing or correction of workmanship and is reported to LG within seven 7 product installation calendar days from the date of delivery 3 Damage or failure caused by leaky broken frozen water 9 Damage or missing items to any display o
24. t remain in the direct airflow from the air conditioner for extended periods of time When used at the same time as stoves fireplaces and other combustion devices make sure there is a sufficient flow of fresh air into the room Do not use in tightly enclosed spaces with these types of devices This air conditioner is intended for household use as a consumer comfort appliance Do not use it as a precision climate control system or for purposes such as cooling precision equipment food pets plants artwork etc Such items could be damaged Do not bend the hose downward when window installation kit is not applied It may cause failure of air conditioner or performance deterioration HOW TO USE ee DB BEFORE USING YOUR AIR CONDITIONER INSERTING BATTERIES IN THE REMOTE Before using your remote install the provided AAA batteries Press and glide the battery cover on the back Basie tonat of the remote then you can remove the cover proper polarity Insert two new alkaline AAA batteries into the battery compartment being sure to note the proper polarity Reattach the battery cover NOTE e Use only alkaline batteries Do not use rechargeable batteries e When replacing batteries always replace both batteries with new batteries Do not mix old and new batteries e If the air conditioner will not be used for an extended period of time remove the batteries from the remote A CAUTION e If the liquid fr
25. unction is selected use the A VW buttons to adjust the delay time from 1 to CONTINUOUS 24 hours in one hour increments After setting continuous the unit will keep running If you press and hold the A VW buttons the set no matter what temperature is selected temperature or time will change automatically after a few seconds AUTO RESTART NOTE The displayed temperature is the SET temperature not the room temperature In COOL or During operation in failure of electric power DRY mode the thermostat in the air conditioner the unit runs as previous setting operation will run the compressor until the set temperature is reached then cycle the compressor on and off to NOTICE Plug in the LED display will light J maintain the set temperature When you plug the power cord into grounded outlet LED display will show room tempreature and power indicator red light LED Display After push power button to operate the product l red light above the power button will be changed gree light LED display shows the set temperature fan speed or the selected TIMER delay O Indicators will light to show active mode and poner additional settings The LED display will show the FL to indicate when the internal water drain tank needs to be emptied ee 12 INSTALLATION INSTRUCTIONS PREPARING FOR INSTALLATION AWARNI NG The air conditioner is heavy Use two or more people to lift and install the unit Failure to do so cou