Home

Professional Weather Center

image

Contents

1. Use standard alkaline batteries or lithium batteries in sensor when temperature is below 4 F 20 C Do not use heavy duty or rechargeable batteries NOTE It may take up to 20 minutes for display unit and sensor to synchronize after batteries are replaced Synchronize the units 1 Bring both the sensor and display unit indoors and remove batteries from each 2 Reinstall batteries in outdoor sensor 3 Reinstall batteries in display unit 4 Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection Outdoor temperature is flashing or showing dashes Flashing of the outdoor temperature may be an indication of wireless interference Make sure the A B C switch in the battery compartments of both the display unit and sensor are switched to the same letter You may choose A B or C but both units must match to sync up Weather Ticker Hard to Read Slow down the speed of the ticker see page 16 Inaccurate forecast Weather Forecast icon predicts conditions for the next 12 to 24 hours not current conditions Has Learning Mode icon disappeared from the display unit Learning Mode must complete before forecast and pressure will be accurate Allow unit to run continuously for 33 days Battery removal or resetting the display unit will restart Learning Mode After 14 days forecast should be fairly accurate however Learning Mode calibrates for a total of 33 days
2. Troubleshooting 20 Problem Possible Solution Inaccurate temperature or humidity Make sure both the display unit and 5 in 1 sensor are placed away from any heat sources or vents see page 11 Make sure both units are positioned away from moisture sources see page 11 Make sure 5 in 1 sensor is mounted at least 5 ft off of the ground Calibrate indoor and outdoor temperature and humidity see page 22 No rainfall Check to ensure the rain gauge stabilizer plastic tab has been removed from the bottom of the sensor see page 7 Clear debris such as leaves out of the rain collector funnel and debris screen Calibrate the Rain Gauge see page 23 Inaccurate wind readings What is wind reading being compared to Pro weather stations are typically mounted at 30 ft high or more Make sure to compare data using a sensor positioned at the same mounting height Check location of the sensor Ensure it s mounted a minimum of 5 ft in the air with no obstructions around it within several feet Ensure wind cups are spinning freely If they hesitate or stop try lubricating with graphite powder or spray lubricant USB connectivity not working Check that the batteries are installed correctly Batteries may need to be replaced Reset the display by pressing the reset button located on the back of the display unit Date and time will need to be entered after a reset Di
3. Display Unit Setup The display unit operates with batteries and or power adapter Regardless of the power source it is recommended that batteries always be installed to ensure continuous operation and retain records in case of a power outage Set the A B C Switch The A B C switch is located inside the battery compartment It can be set to A B or C However you must select the same letter choices for both the sensor and the display unit in order for the units to synchronize Install or Replace Batteries Insert 6 x AA alkaline batteries into the battery compartment as shown Follow the polarity diagram in the battery compartment Write Down the MAC ADDRESS 12 digit unique ID needed for online connectivity functions Plug Power Adapter into Electric Outlet optional PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS BATTERY SAFETY Clean the battery contacts and also those of the device prior to battery installation Remove batteries from equipment which is not to be used for an extended period of time Follow the polarity diagram in the battery compartment Promptly remove dead batteries from the device Dispose of used batteries properly Only batteries of the same or equivalent type as recommended are to be used DO NOT incinerate used batteries DO NOT dispose of batteries in fire as batteries may explode or leak DO NOT mix old and ne
4. is applied to the LCD screen prior to using this product Locate the tab and peel off to remove Package Contents 1 Display unit with tabletop stand 2 5 in 1 sensor 3 Sensor mounting bracket 4 Mounting hardware 5 Snap in debris filter for rain collector 6 Power adapter 7 USB cable 6 Instruction Manual PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Register a Product 3 Features amp Benefits 7 2 1 9 8 10 5 6 11 4 3 5 IN 1 SENSOR 1 Rainfall Collector Funnel 2 Solar Cell Panel Converts sunlight into power to run internal aspirating fan Internal Aspirating Fan not shown Draws ambient air into sensor to reduce solar radiation heating resulting in more accurate temperature measurement 3 A B C Switch ID code that must match display s A B C switch to ensure units synchronize 4 Battery Compartment 5 Temperature amp Humidity Sensors internal 6 Mounting Point 7 Wind Speed Anemometer 8 Wind Direction Vane 9 Mounting Bracket 10 Mounting Hardware includes anchors amp screws 11 Debris Filter Snaps into rain collector to filter out twigs leaves etc 4 Features amp Benefits Display Unit 41 2 1 5 21 22 23 24 25 26 27 28 29 30 32 31 33 34 35 36 7 10 11 12 13 14 37
5. t register close to 1 06 make an EQUAL adjustment to the two calibration screws on the bottom of the 5 in 1 sensor Turning screws clockwise increases rainfall counter clockwise decreases rainfall To adjust the rainfall reading by 2 turn both screws 1 8 of a turn To adjust the rainfall reading by 4 turn both screws 1 4 of a turn To adjust the rainfall reading by 8 turn both screws 1 2 of a turn 24 FCC Information This device complies with part 15 of FCC rules Operation is subject to the following two conditions 1 This device may NOT cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However There is no guar antee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of
6. to set the speed preference 3 Press the up or down arrows to select a speed SLOW NORMAL or FAST 4 Press the button to confirm your selection Weather Ticker speed is now set Weather Ticker The Weather Ticker automatically streams your real time weather information and alerts as scrolling text in the lower part of the display unit screen You can manually cycle through all the available messages by pressing Default WEATHER TICKER messages are pre loaded as follows FORECAST 12 to 24 hour future weather forecast MOON PHASE Current moon phase INDOOR COMFORT Dry OK or humid comfort level IT FEELS LIKE __ OUTSIDE Calculates what temperature it feels like outdoors based on temperature humidity and wind speed OUTDOOR TEMP THIS WEEK HIGH Highest temperature recorded this calendar week OUTDOOR TEMP THIS WEEK LOW Lowest temperature recorded this calendar week OUTDOOR TEMP THIS MONTH HIGH Highest temperature recorded this calendar month OUTDOOR TEMP THIS MONTH LOW Lowest temperature recorded this calendar month 17 Customize Weather Ticker Messages Customize which messages you want to scroll across the WEATHER TICKER 1 Press the button to manually cycle through each message available 2 During the MANUAL REVIEW PRESS the button to activate the current scrolling message The corresponding appears on screen to the left of the message to indicate the message
7. unit Clean the Rain Collector Cup Remove and empty rain collector debris filter The debris filter is located in the rain col lector funnel Remove from the top by gently squeezing and pulling out Clean the Wind Vane amp Anemometer Remove foreign matter from the outside of the sensor for free movement of the wind vane and anemometer If needed use a small amount of spray lubricant clear silicone or graphite powder on the anemometer for improved movement Calibration Calibrate Temperature amp Humidity The indoor outdoor temperature and humidity readings can be calibrated on the display unit to improve accuracy Calibration improves accuracy when 5 in 1 sensor placement or environmental factors impact your data accuracy 1 Choose the weather category you wish to calibrate by pressing the up or down arrow buttons until the category is displayed on the Selectable Category part of the display unit 2 Press AND HOLD the up and down arrow buttons and the button all at the same time for 15 20 seconds The display unit beeps and all display data is hidden except for the value being calibrated calibrate and arrows appear next to the value being calibrated 23 3 Press the up or down arrow buttons to calibrate the data value higher or lower from the actual reading 4 Press the button to confirm the calibration adjustment Note The icon remains illuminated next to calibrated va
8. 38 39 40 14 18 17 16 16 19 15 20 8 9 6 4 3 5 1 Peak Wind Speed Highest speed from past 60 minutes 2 Average Wind Speed of all speeds from past 2 minutes 3 Storm Alert Alarm On Indicator 4 Weather Select top to bottom Heat index dew point wind chill indoor temperature humidity rainfall rate rain per hour 5 Current Barometric Pressure Arrow icon indicates direction pressure is trending 6 Weather Select Button Press to change the Weather Select category data being displayed 7 Learning Mode Icon Disappears after weather forecast self calibration is complete 8 5 in 1 Sensor Signal Strength 9 5 in 1 Sensor Low Battery Indicator 10 Alarm On Off Indicator for Selectable Category 33 11 Programmable Alarm Settings 12 Indicates Active Weather Ticker Message During ticker customization mode 13 Indicates Deactivated Weather Ticker Message During ticker customization mode 14 Alarm On Off Button Activate alarm press and hold to adjust alarm values 15 Deactivates Weather Ticker Message 16 Up Down to Select Category shown in 33 amp Adjust Settings 17 Settings Button 18 Weather Ticker Manual Cycle Press to advance through messages 19 All Time Records Button Press for all time low and date recorded for current category selected on display 33 Press twice for all time high and date recorded 20 Activates Weather Ticker Message 21 Current Outdoor Temperature Arrow i
9. C Connect preferences and advanced features Visit www AcuRite com and click on PC Connect Download under the SUPPORT menu to download the software to your computer Connect small end of USB cable into USB plugin on the back of the display unit inside the battery compartment area Connect large end of the USB cable to a USB port on your PC Click on the setupacu link file and follow the instructions to install AcuLink PC Connect software A folder named AcuRite will be installed on your PC NOTE PC Connect software may take up to 1 minute upon startup to receive data from display unit PC Connect is now ready for use PC Connect Acu Link PC Connect Acu Link PC Connect Acu Link PC Connect v X on your computer SUPPORT PC 1 2 3 4 15 OPERATION Using the Professional Weather Center Learning Mode Self Calibrating Forecasting use a unique algorithm to analyze changes in pressure over a time period called Learning Mode to determine your altitude After 14 days the Learning Mode icon disappears from the display screen At this point the self calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction Weather Forecast AcuRite s patented Self Calibrating Forecasting provides your personal forecast of weather conditions for the next 12 to 24 hours by collecting data from the sensor in your backyard It generates a forecast with pinpoint ac
10. Instruction Manual SAVE THIS MANUAL FOR FUTURE REFERENCE Questions Contact Customer Support at 877 221 1252 or visit www AcuRite com CONTENTS Unpacking Instructions 2 Package Contents 2 Product Registration 2 Features amp Benefits 5 in 1 3 Features Display Unit 4 Back of Display Unit 6 Setup 7 5 in 1 Sensor Setup 7 Display Unit Setup 8 Set the Time amp Date 9 Measurement Units 10 Set Language 10 Sensor amp Display Placement 11 5 in 1 Sensor Installation 12 PC Connect Overview 13 PC Connect USB Modes 13 PC Connect Software 14 Using the Weather Center 15 Weather Ticker 16 Programmable Alarms 18 Troubleshooting 19 Care amp Maintenance 22 Calibration 22 Specifications 24 FCC Information 24 Customer Support 25 Warranty 25 Professional Weather Center model 01525 2 Congratulations on your new AcuRite product To ensure the best possible product performance please read this manual in its entirety and retain it for future reference Unpacking Instructions Remove the protective film that
11. LER HEADS DO NOT install the sensor where it will be sprayed by a sprinkler system This may force water inside the sensor LOCATE AWAY FROM WIND amp RAIN OBSTRUCTIONS DO NOT mount the sensor with obstructions around it Consider a location that is a wide open area with few structures around to ensure accurate wind measurement Visit us online to view installation photos and video or learn more about AcuRite technology www AcuRite com 5in1 View Video 12 5 in 1 Sensor Installation Guidelines INSTALLATION HEIGHT Mount the sensor at least 5 feet 1 5 meters off the ground higher is better for wind measurement in an open area Secure to fence post 4 x 4 wood 3 4 pole etc not included LEVEL INSTALLATION Use the bubble level on the top of the sensor to ensure level installation for accurate wind and rain measurement SOLAR CELL INSTALLATION Install the sensor with the solar cell facing SOUTH This ensures the cell receives as much sun as possible and orients wind direction 5 in 1 Sensor Installation 1 Fasten mounting base included to a post or pole not included using the 4 longer screws included in the hardware bag 2 Insert the mounting base into the hole on the bottom of the sensor 3 Make sure the arrows on the top of the sensor are pointed in the proper direction and the bubble level is centered The solar cell should be facing south to properly orient the wind direction 4 Fasten the sensor i
12. aced by Chaney Transportation costs and charges for returned goods shall be paid for by the purchaser Chaney hereby disclaims all responsibility for such transportation costs and charges This warranty will not be breached and Chaney will give no credit for products it manufactures which have received normal wear and tear been damaged including by acts of nature tampered abused improperly installed damaged in shipping or repaired or altered by others than authorized representatives of Chaney The above described warranty is expressly in lieu of all other warranties express or implied and all other warranties are hereby expressly disclaimed including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose Chaney expressly disclaims all liability for special consequential or incidental damages whether arising in tort or by contract from any breach of this warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law By acceptance of any of Chaney s products the purchaser assumes all liability for the consequences arising from their use or misuse No person firm or corporation is authorized to assume for Chaney any other liability in connection with the s
13. ale of its products Furthermore no person firm or corporation is authorized to modify or waive the terms of this paragraph and the preceding paragraph unless done in writing and signed by a duly authorized agent of Chaney This warranty gives you specific legal rights and you may also have other rights which vary from state to state For in warranty claims Chaney Instrument Co 965 Wells St Lake Geneva WI 53147 Limited One Year Warranty PRODUCT REGISTRATION Register online to receive 1 year warranty protection www AcuRite com IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE Register a Product Customer Support AcuRite customer support is committed to providing you with best in class service For assistance please have the model number of this product available and contact us in any of the following ways 877 221 1252 info chaney inst com 24 7 support at www AcuRite com Installation Videos Register your Product Instruction Manuals Support User Forum Replacement Parts Submit Feedback amp Ideas Chaney Instrument Co All rights reserved AcuRite is a registered trademark of the Chaney Instrument Co Lake Geneva WI 53147 All other trademarks and copy rights are the property of their respective owners AcuRite uses patented technology Visit www AcuRite com patents for details Printed in China 01525 INST 092013 It s More than Accurate it s AcuRi
14. con indicates direction temperature is trending 22 Outdoor Temperature Alarm On Indicator 23 Current Outdoor Humidity Arrow icon indicates direction humidity is trending 24 Outdoor Humidity Alarm On Indicator 25 Current Rainfall Accumulates data during rainfall 26 Rainfall Alarm On Indicator 27 12 to 24 Hour Weather Forecast Self Calibrating Forecasting pulls data from the outdoor sensor to generate your personal forecast 28 All Time Rainfall 29 Current Month Total Rainfall 30 Date 31 Clock 32 Display Unit Low Battery Indicator 33 Selectable Category 34 Record Highs Shown for current category selected on the display 33 35 Record Lows Shown for current category selected on the display 33 36 Weather Ticker 37 Previous 2 Wind Directions 38 Current Wind Direction 39 Current Wind Speed 40 Wind Speed Alarm On Indicator 41 Touch Activated Backlight Momentary during battery power always on off for power adapter 6 Back of Display Unit 1 2 3 BACK OF DISPLAY UNIT 1 Integrated Hang Hole for easy wall mounting 2 Plugin for USB Cable 3 Plugin for Power Adapter 4 A B C Switch ID code that must match 5 in 1 sensor s A B C switch to ensure units synchronize 5 Clear Today Clears data recorded since 12 00am 6 Clear All Clears all recorded data 7 Reset Full reset to factory defaults 8 Battery Compartment 9 MAC ADDRESS 12 digit unique ID required for online conne
15. ctivity functions 10 Power Adapter 11 USB Cable for PC Connection 12 Battery Compartment Cover not shown 10 11 4 5 6 7 8 9 7 A B C SETUP 5 IN 1 Sensor Setup 1 A B C Switch Set to match display unit 2 Install Batteries 4 AA Batteries 3 Rain Gauge Stabilizer Remove and discard Set the A B C Switch Locate the A B C switch inside the battery compartment Set the A B C switch to A B or C You must select the same letter choices for both the sensor and the display unit in order for the units to synchronize Install or Replace Batteries Batteries MUST be installed for this product to operate AcuRite recommends high quality alkaline or lithium batteries for the best product performance Heavy duty or rechargeable batteries are not recommended The 5 in 1 sensor requires lithium batteries in low temperature conditions Cold temperatures can cause alkaline batteries to function improperly Use lithium batteries in the 5 in 1 sensor for temperatures below 4 F 20 C 1 Slide off the battery compartment cover 2 Insert 4 x AA batteries into the battery compartment as shown Follow the polarity diagram in the battery compartment 3 Replace the battery cover Remove Rain Gauge Stabilizer Locate and remove the rain gauge stabilizer plastic tab taped into the bottom of the sensor The rain gauge will not function until this is removed 2 3 1 8
16. curacy personalized for your exact location View the complete list of icons at www AcuRite com acurite icons Weather Select Features weather data groups shown at right To change Weather Select category press the selection arrow button just to the left of the weather select display area Rainfall Event The rainfall feature tracks rain accumulation over all time the current month and current rainfall event Current event clears when no rain registers for 8 hours OR no rain registers for 1 hour and pressure rises by 03inhg or more Barometric Pressure Subtle variations in barometric pressure greatly affect the weather This weather center displays the current pressure with an arrow icon to indicate the direction the pressure is trending FALLING STEADY or RISING RAIN LIKELY SNOW LIKELY CHANCE OF MIXED RAIN amp SNOW CLOUDY PARTLY CLOUDY STORM LIKELY Heat Index Dew Point Wind Chill Indoor Conditions Rainfall Rate in hour 16 Additional Messages Include NEW HIGH TEMPERATURE RECORD NEW LOW TEMPERATURE RECORD NEW WIND SPEED RECORD TODAY CURRENT RAINFALL RATE CURRENT RAIN EVENT STARTED NO RAIN RECORDED SINCE ____ WEATHER ALARM MESSAGES SENSOR BATTERIES LOW SENSOR SIGNAL LOST Adjust the Weather Ticker Speed 1 Press the up or down arrow buttons until TICKER SPEED is displayed on the Selectable Category part of the display unit 2 Press the button
17. display unit runs out of power or is reset 11 Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding environmental conditions Proper placement of both the display unit and the sensor are critical to the accuracy and performance of this product Display Unit Placement Place the display unit in a dry area free of dirt and dust To ensure accurate temperature measurement place out of direct sunlight and away from heat sources or vents Display unit stands upright for tabletop use or is wall mountable 5 in 1 Sensor Placement The 5 in 1 sensor is designed to remain outdoors all year long Choose an open location with no obstructions above or around the sensor for the most accurate measurements Important Placement Guidelines Display unit and sensor must be within 330 feet 100 m of each other MAXIMIZE WIRELESS RANGE Place units away from large metallic items thick walls metal surfaces or other objects that may limit wireless communication PREVENT WIRELESS INTERFERENCE Place both units at least 3 feet 9 m away from electronic devices TV computer microwave radio etc LOCATE AWAY FROM HEAT SOURCES Position sensor away from heaters air conditioners chimneys exhaust vents asphalt and concrete surfaces that radiate heat LOCATE AWAY FROM HUMIDITY SOURCES Avoid installing the sensor near pools spas or other bodies of water Water sources may impact humidity accuracy LOCATE AWAY FROM SPRINK
18. e The storm alarm is NOT intended to be a safety device or warning system Set a Weather Alarm 1 Choose the weather category for which you wish to set an alarm by pressing the up or down arrow buttons until the category is displayed on the Selectable Category part of the display unit 2 To program a value only applies to alarms that require a value press AND HOLD the button underneath the alarm you wish to set until the indicator appears and the alarm setting flashes 3 Adjust the alarm value by pressing the up or down arrow buttons 4 Press the button to confirm a value 5 Next press the button to activate the alarm the X indicator disappears when alarm is activated Alarm is now programmed and turned on Silence a Sounding Alarm The alarm sounds initially for a few minutes then silences itself The alarm then sounds every few minutes afterwards until one of the following happens 1 SNOOZE Press any button Alarm silences but sounds again if the alarm condition reoccurs 2 Turn alarm OFF Deactivates alarm 19 Problem Possible Solution No outdoor sensor reception no bars Relocate the display unit and or the 5 in 1 sensor The units must be within 330 ft 100 m of each other Make sure both units are placed at least 3 feet 9 m away from electronics that may interfere with the wireless communication such as TVs microwaves computers etc
19. ect in your account at www aculink com and on the AcuLink mobile app Restart the PC Connect Software Restart your PC PC Connect software data is different than display unit data Check that the USB cable is securely connected to the display unit AND to your PC USB port Confirm that the correct USB mode is selected on your display unit Restart the PC Connect Software Unplug the USB cable from your PC for about 1 minute re insert USB port may be malfunctioning try another USB port Troubleshooting 22 Care amp Maintenance Display Unit Care Clean with a soft damp cloth Do not use caustic cleaners or abrasives Keep away from dust dirt and moisture Clean ventilation ports regularly with a gentle puff of air 5 in 1 Sensor Care Clean the Sensor Clean with a soft damp cloth Do not use caustic cleaners or abrasives that will mar the polished surfaces of the rain collection funnel or the solar cell Scratches will result in decreased performance and reliability Insect Prevention Insects may cause obstructions and interrupt data by nesting in or on the 5 in 1 sensor To limit this problem spray sensor with a household insect repellent Consult the insect repellent instructions prior to use Snow amp Freezing Weather The 5 in 1 sensor will not be damaged by freezing conditions NOTE If the rain collec tor cup fills with snow and then melts it will register as rain on the display
20. is now active in the ticker cycle PRESS the button to deactivate the current scrolling message The corresponding appears on screen to the left of the message to indicate the message is now deactivated from the ticker cycle Please note Messages can only be added and removed to the ticker cycle during manual review The and buttons do not add or remove messages during the automatic cycle Remove message from cycle Message activated Message deactivated Manual cycle through messages Add message to cycle 18 Alarm On Alarm Off Adjust Mode Low Value High Value Press to activate or deactivate an alarm Press and hold to set or adjust an alarm value ICON DEFINITIONS BUTTON FUNCTIONS Programmable Weather Alarms Each Selectable Weather Category features an alarm option When an alarm sounds the display unit emits audible beeping and flashes the affected category its alarm settings and any other relevant data Some alarms can be customized to alert you when your programmed value is reached Alarms include outdoor temperature outdoor humidity wind speed heat index dew point wind chill indoor temperature and indoor humidity The rain alarm does not require a preset numerical value but instead sounds as soon as rain is recorded Similarly the storm alarm sounds when a large atmospheric pressure drop occurs which usually indicates an oncoming storm Not
21. lay unit s Weather Ticker displays an alert to download memory soon Transfer data to your PC using PC Connect USB Mode 2 Display Logging OFF DEFAULT Display unit DOES NOT log save any data in memory for PC transfer USB Mode 3 Display Logging ON Internet Bridge Mode Display unit logs stores up to 2 weeks of data in memory Transfer data to your PC using PC Connect Stream your data from your weather center to online sources USB Mode 4 Display Logging OFF Internet Bridge Mode Display unit DOES NOT log save any data in memory Stream your data from your weather center to online sources PC and internet connection must remain ON to continuously stream data from your weather center to online sources or the AcuLink mobile app Set the PC Connect USB Mode 1 Press the up or down arrow buttons until SET USB MODE is displayed on the Selectable Category part of the display unit 2 Press the button to set the mode preference 3 Press the up or down arrows to select the USB mode 4 Press the button to confirm your selection PC Connect USB Mode is now set Stores Data Shows Data USB Mode Streams Online 2 1 4 3 DISPLAY UNIT 14 Download the PC Connect Software PC Connect software is available as a free download online The PC Connect instruction manual is a PDF file that is included in the software download Read the manual to learn how to setup P
22. lues Calibrate the Rain Gauge The rain gauge on the 5 in 1 sensor can be calibrated to improve accuracy Items Needed 5 in 1 sensor display unit plastic cup pin screw driver 1 First ensure 5 in 1 sensor is perfectly level using built in bubble level 2 Place display unit close so you can monitor it during calibration 3 Make a pin hole in the bottom of a plastic cup Hold the cup over the rain gauge and fill it with exactly 1 cup 8oz of water allowing the water to drip into the rain gauge You should hear the internal buckets tip and see water drain through the rain gauge 4 A few seconds after each bucket tip the display unit displays rainfall in approximately 0 01 or more increments 5 The cup of water should take more than 20 minutes to empty a quicker period will result in inaccurate calibration Try to simulate a normal steady rainfall When cup is empty of water display unit should register 1 06 Tips There should be nearly an equal number of water drops about 25 water drops between bucket tips If not adjust the calibration screws on the bottom of the 5 in 1 sensor until an equal number of water drops are tipping the buckets Then restart the calibration procedure If you don t hear the buckets tipping and see water dripping alternately out of each drain there may be an issue with the rain gauge or it s adjustment See Troubleshooting on page 20 Adjustment If the rain gauge doesn
23. nto the mounting base using the 2 shorter screws included in the hardware bag The 5 in 1 sensor is now ready to use Clear Data Collected During Installation When installation is complete clear erroneous data from the display unit by pressing the CLEAR TODAY button on the back of the display until inside the battery compartment This button will clear data recorded since 12 00 am Basic Setup is Complete The 5 in 1 sensor will now synchronize with the display unit It may take a few minutes for synchronization to complete If both or one of the units appear to be functioning improperly please refer to the troubleshooting section SOUTH 1 5 meters NO OBSTRUCTIONS ABOVE OR AROUND 13 PC Connect Overview PC Connect lets you access your Weather Center data in the following ways Data File Display unit logs or stores data so that you can download it to a PC in a data file CSV or comma separated values file PC Weather Widget View data on your PC s screen as a widget Web Browser or Smartphone Monitor sensor data remotely using AcuRite s free AcuLink online software or from a mobile device using the free AcuLink app available from the iPhone App Store or Android Market PC Connect USB Modes To setup PC Connect you must first select a USB mode on the display unit USB Mode 1 Display Logging ON Display unit logs stores up to 2 weeks of data in memory When memory nears capacity disp
24. selection 5 Press the up or down arrows to adjust the day 6 Press the button to confirm day selection 7 Press the up or down arrows to adjust the year 8 Press the button to confirm year selection The date is now set Note The stays in Selectable Categories even after setup 10 Select Measurement Units To select between standard units mph F etc or metric units kph C etc 1 Press the up or down arrow buttons until SET UNITS is displayed on the Selectable Category part of the display unit 2 Press the button to set the unit preference 3 Press the up or down arrows to select STAND for standard or METRIC for metric units 4 Press the button to confirm your selection 5 Next you will see WIND MPH Press the up or down arrows to select MPH KPH or KNOTS for wind speed units 6 Press the button to confirm your selection Units are now set Set Language To select between English default or Spanish for the display unit language 1 Press the up or down arrow buttons until SET LANG is displayed on the Selectable Category part of the display unit 2 Press the button to set the language preference 3 Press the up or down arrows to select the desired language 4 Press the button to confirm your selection Language is now set Note Display unit reverts to English language when
25. splay screen not working Check that the batteries are installed correctly Batteries may need to be replaced Reset the display by pressing the reset button located on the back of the display unit Date and time will need to be entered after a reset Troubleshooting 21 If your AcuRite product does not operate properly after trying the troubleshooting steps visit www AcuRite com or call 877 221 1252 for assistance Problem Possible Solution Cannot access data online or on the AcuLink mobile app Confirm the status readout in PC Connect software on your PC indicates that data was uploaded OK Make certain you created an account or logged into your existing account on www aculink com and that you have setup your display unit MAC ADDRESS online as well Check that the USB cable is securely connected to the display unit AND to your PC USB port Make certain the display unit is powered on Make certain the PC your display unit is connected to is always powered on Make certain the PC your display unit is connected to is always connected to the internet Confirm the display unit USB mode is 3 or 4 Confirm your display unit MAC ADDRESS is entered into the UPLOAD window correctly in the PC Connect Software on your PC Confirm that the ENABLE box is checked in the UPLOAD window in the PC Connect Software on your PC Confirm your display unit s MAC ADDRESS is corr
26. te offers an extensive assortment of precision instruments designed to provide you with information you can depend on to Plan your day with confidence www AcuRite com Weather Stations Temperature amp Humidity Weather Alert Radio Kitchen Thermometers amp Timers Clocks
27. the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help NOTE The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user authority to operate the equipment This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference received including interference that may cause undesired operation of the device Specifications TEMPERATURE RANGE Outdoor 40 F to 158 F 40 C to 70 C Indoor 32 F to 122 F 0 C to 50 C HUMIDITY RANGE Outdoor 1 to 99 Indoor 16 to 98 WIND SPEED 0 to 99 mph 0 to 159 kph WIND DIRECTION INDICATORS 16 points RAINFALL 0 to 99 99 in WIRELESS RANGE 330ft 100m depending on home construction materials OPERATING FREQUENCY 433 MHz POWER 10 x AA alkaline or lithium batteries not included AC DC power adapter input 120V 60Hz Output 4 5VDC 250mA DATA REPORTING Wind Speed 18 second updates Direction 30 seconds Outdoor temperature amp humidity 36 second updates Indoor tempera
28. ture amp humidity 60 second updates PC Connect CSV Data Logging 12 minute intervals PC Connect to AcuLink Software App 18 seconds DISPLAY UNIT MEMORY 512 kilobytes not expandable PC CONNECT SYSTEM REQUIREMENTS Windows XP Vista 7 and available USB port High speed internet is required to use some advanced features of PC Connect such as the AcuLink My Backyard Weather software and app 25 At AcuRite we proudly uphold our commitment to quality technology Chaney Instrument Co warrants that all products it manufactures to be of good material and workmanship and to be free of defects when properly installed and operated for a period of one year from the date of purchase We recommend that you visit us at www AcuRite com for the fastest way to register your product However product registration does not eliminate the need to retain your original proof of purchase in order to obtain warranty benefits Chaney Instrument Co warrants that all products it manufactures to be of good material and workmanship and to be free of defects when properly installed and operated for a period of one year from the date of purchase Remedy for breach of this warranty is limited to repair or replacement of the defective item s Any product which under normal use and service is proven to breach the warranty contained herein within ONE YEAR from date of sale will upon examination by Chaney and at its sole option be repaired or repl
29. w batteries or types of batteries alkaline standard DO NOT use rechargeable batteries DO NOT recharge non rechargeable batteries DO NOT short circuit the supply terminals 2 3 4 1 2 Install Batteries 6 AA Batteries 3 Write Down MAC ADDRESS 12 digit number 4 Plug in Power Adapter optional A B C 1 A B C Switch set to match sensor Momentary backlight during battery power Backlight can always remain on or off when power adapter is plugged in LIGHT 9 Set the Time amp Date The clock and calendar are utilized to time stamp history records and other data so it is important to set the time and date soon after you power on the display unit Set the Time 1 Press the up or down arrow buttons until SET CLOCK is displayed on the Selectable Category part of the display unit 2 Press the button to set the clock 3 Press the up or down arrows to adjust the hour Note the AM and PM indicators 4 Press the button to confirm hour selection 5 Press the up or down arrows to adjust minutes 6 Press the button to confirm minute selection The clock is now set Set the Date 1 Press the up or down arrow buttons until SET DATE is displayed on the Selectable Category part of the display unit 2 Press the button to set the date 3 Press the up or down arrows to adjust the month 4 Press the button to confirm month