Home

SKF @ptitude Analyst - SKF Maintenance Services

image

Contents

1. statistics and others SKF ptitude Analyst Powerful software for enterprise wide communications www skf com cm 6 SKF ptitude Analyst features and capabilities ALARMS e Alarm window Quickly find and identify all points in alarm within the hierarchy group route workspace or machine e Alarm details Provides a summary of type of alarm and status e User defined alarm levels Public alarms that can be shared with other users Private alarms that can only be used by specific users Unlimited number of alarms can be configured e Four overall alarm levels per measurement point Danger high alert high alert low danger low Enhanced event log capabilities Multilog Out of window in window level alarms supported e Alarm types Overall forecast Overall percent change Unlimited spectral band overall and peak Spectral envelope Phase angle Overall Inspection MARLIN condition detector Variable speed alarms Crash alarm Multilog TMU only BOV alarming Statistical alarm calculation COMMUNICATION e Automatic report generation based on a specified time data upload via scheduler wizard e Data transfer with SKF MARLIN and Microlog CMVA CMXA and GX series systems Multilog DMx TMU CMU LMU WMU e Download by Hierarchy Route or Workspace e Microsoft ActiveSynch Serial USB Ethernet and others e OPC client
2. with Service Pack 3 Processor Note 1 Pentium IV 2 0 GHz Pentium IV 3 2 GHz Core 2 Duo RAM 2 0 GB 4 0 GB or more Quantity of hard drives Note 3 3 5 Disk space available Note 3 1 2 GB 1 2 GB or more Oracle Microsoft SQL Version 9i 10g SQL Server 2005 Minimum Requirements Recommended Requirements Operating system Windows 2000 with Service Pack 3 OR Windows XP Professional with Service Pack 2 Processor Note 1 Pentium IV 1 6 GHz Pentium IV 2 4 GHz Core 2 Duo RAM 1 0 GB 2 0 GB or more Disk space available for each network client 200 MB 500 MB or more Note 2 CD DVD drive One 1 required One 1 required Video display 1024 x 768 1280 x 1024 or larger Oracle Microsoft SQL Version 9i 10g SQL Server 2005 NOTE 1 These requirements apply to SKF ptitude Analyst complete with database management system Other applications running simultaneously may degrade performance NOTE 2 These requirements ONLY apply to SKF ptitude Analyst complete with database management system Additional storage disk space is required for data NOTE 3 The major benefits of spreading Oracle across three or more hard disks at the server is the improved speed and improved recoverability of a previously archived database The recommended five disk configuration provides the optimal protection for backup recovery indexing and speed Disk file configuration should ONLY be handled by a SKF Field Service Technici
3. Powerful software for enterprise wide communications SKF ptitude Analyst is a core platform in a family of reliability software applications that work together as SKF ptitude Monitoring Suite SKF ptitude Analyst is a comprehensive software solution with powerful diagnostic and analytical capabilities ptitude Analyst provides fast efficient and reliable storage analysis and retrieval of complex machine information and makes the information accessible throughout your organization e One software program to manage machinery condition data from portable and on line devices One installation with limitless expansion capabilities Easy to learn and use for novice or experienced users Interconnectivity with other software programs and systems Easy personalization for individual users When you select ptitude Analyst you are immediately equipped to integrate and analyze data from the full range of SKF data collection devices This enterprise wide software platform allows operations maintenance and reliability staff to view the integrated data and communicates the information to each department ina customized format to meet individual user needs ptitude Analyst can incorporate data from other sources such as OPC and OSlsoft Pl System and seamlessly interface to your SAP Computerized Maintenance Management System CMMS Enterprise resource planning On line surveillance protection Computer
4. an certified on SKF ptitude Analyst If using RAID the combination of RAID O and RAID 1 is recommended over RAID 5 NOTICE If running other versions of Oracle Microsoft SQL Server or other database management system are expected to run in the same PC environment please contact your local SKF Representative to inquire about compatibility SKF ptitude Analyst Powerful software for enterprise wide communications SKF Reliability Systems Web Site www skf com cm Ordering information e SKF ptitude Analyst software for Microlog MARLIN TMU DMx CMU LMU MIM and WMU CMSW 7400 e SKF ptitude Analyst for Microlog Analyzer CMSW 7300 The SKF ptitude Analyst is available in Single and Multi Client configurations Please contact your local SKF Reliability Systems representative for Multi Client model information 5271 Viewridge Court e San Diego California 92123 USA Telephone 1 858 496 3400 e FAX 1 858 496 3531 The contents of this publication are the copyright of the publisher and may not be reproduced even extracts unless permission is granted Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct indirect or consequential arising out of the use of the information contained herein SKF reserves the right to alter any part of this publication without prior notice SKF Patents includ
5. at that suits you best Automated features simplify configuring and fine tuning alarms Since similar machines often use the same alarms the Alarm Database provides user defined alarms that can be applied to create alarm settings for multiple measurement points An Alarm Wizard assists in creating Statistical Alarms to set alarms for your most important machinery with minimal research and effort ptitude Analyst considers historical data and natural variation in vibration levels of machinery and generates a reliable set of alarm criterion tailored to the specific machine ptitude Analyst s variable speed alarming features accommodate normal fluctuations in machine speed and function Alarm limits are automatically reset as speed changes preventing false alarms Robust capabilities that are easy to use SKF ptitude Analyst makes analysis easier by combining powerful data mining technology analytical displays and user friendly graphics e Preference options let ptitude Analyst work the way you work e Single views trends and overlays expand your analysis capabilities e Easy to read plots provide detailed information Detailed information efficiently organized Screen displays such as data plot layout color size and position can be personalized and automatically updated A customizable toolbar facilitates quick access to the program features you use most frequently Right click on your data plot to modify setting
6. e US05854553 US05845230 US06489884 US05679900 US04768380 US06199422 US05992237 US06202491 US06513386 US06275781 US06633822 US06006164 US2003_0178515A1 US6 789 025 US6 789 360 US 5 633 811 and US 5 870 699 WO_03_048714A1 e SKF ptitude MARLIN Multilog and Microlog are registered trademarks of the SKF Group e Oracle is a registered trademark of Oracle Corporation e Microsoft Windows PowerPoint Word and Excel are registered trademarks of Microsoft Corporation OSlsoft is a registered trademark and PI System is a trademark of OSlsoft Inc e All other trademarks are the property of their respective owners CM2362 5 07 Copyright 2007 by SKF Condition Monitoring Inc ALL RIGHTS RESERVED Product Support Plans PSP A range of Product Support Plans are available to protect your investment Contact your local SKF Reliability Systems Sales Representative for additional information Installation and training Installation and training available through your local SKF Supplier or Representative
7. ew individual routes and workspaces ptitude Analyst s database management tools allow you to closely track machine problems to recreate events for predictive maintenance and to perform root cause failure analysis SKF ptitude Analyst Powerful software for enterprise wide communications www skf com cm 3 Alarm view ELLES AeA M LEELEE 8 FOS TSO2i00 _JP4 REFINER INLET PSI Amp 0 Date Tene 9232004 43129 PM Trend spectrum and other plots can be displayed for each machine in alarm for further analysis Multi pane plots E e r a GBG0G608 600 8 8ss 7 NOEM Trend Water Pump 420 1 HORZ IPS Channel X Vater Pras 4 H2O 1 HORZ IPS Amp 0 3711 Date Tese 521 1994 92208 PM 21 1994 9 2208 PM For Heb press F1 3 TUNED ptitude Analyst allows you to view multiple data plots in a single window View Trend Spectrum Trend Spectrum Time and more to make the most reliable and accurate decisions on machinery SKF ptitude Analyst Powerful software for enterprise wide communications www skf com cm 4 Access and security Controlling access while effectively communicating information ptitude Analyst permits access on a customized basis yet allows the effective exchange of detailed information across functional departments e Definable security protects your valuable data e Easy and flexible reporting options e Automated functions minimize human error Administrator Modity custom le
8. interface available DATA DISPLAY e Orbit Syncronized cursoring Smax locator Flash blank Filtering Vector compensation Waveform compensation True sensor angle compensation Tacho offset compensation e Shaft centerline e Overall trend displays e MARLIN condition detector e Temperature e Digital images e Spectrum displays waterfall palogram e Single point multiple point displays e Phase displays polar vector magnitude phase e Triaxial point e Time waveform displays Single point multiple points e Multi channel display e Combination graphs Orbit time Trend spectrum Trend spectrum time waveform Trend speed Trend speed spectrum Trend speed spectrum time Trend speed time Waterfall extracted trend spectrum Waterfall extracted band trend Trend time waveform Spectrum band trend Live views Multilog Live bars Multilog e Graph overlays e Spectrum Single harmonic sideband peak band cursors On screen defect frequency Running speed Spectral band alarm Spectral envelope alarm Overall alarms e Display tools Display information area On screen text annotation Percent of full scale setting Auto scaling Cursor micro manipulation Autolinking of displays and active hierarchy Linear or log X or Y scaling Grid Orders frequency scaling Amplitude threshold Waterfall sla
9. ized Maintenance Management System SKF ptitude decision support Q Periodic vibration process data SKF ptitude monitoring suite SKF ptitude Observer SKF ptitude Inspector Enterprise Resource Planning ERP or other information management systems ptitude Analyst s integrated platform forms the hub to share information foster teamwork and facilitate consistent and reliable decision making across functional departments The addition of ptitude Decision Support automates reliability maintenance decision making by identifying probable faults with an asset or process then prescribing appropriate action SKF ptitude Analyst Powerful software for enterprise wide communications www skf com cm 2 Diagnosis and analysis Managing the condition of your assets is easy with ptitude Analyst e Flexible setup gives you complete control e Alarm viewing options let you quickly focus on priorities e Built in tools streamline data management Machine data customized for your unique needs From the way you set up databases routes and analysis parameters to the customized format for reporting you are in control of powerful analysis tools You can collect information based on location machine type frequency or other selections ptitude Analyst allows you to determine the appropriate limits for alarm conditions and how alarms are categorized to ensure you receive consistent reliable data in the form
10. lly configurable user rights that allow you to read view and have full access e Unlimited access levels e Allows assignment of access rights to user groups e Hierarchy access an enhanced security feature that authorizes viewing and manipulation of hierarchies TEMPLATES AND WIZARDS e Statistical alarm wizards use historical data to help refine overall alarms e Hierarchy template wizard allows for rapid hierarchy creation and machine templates for reuse e Report template allows for the custom configuration of reports and report templates for reuse e Scheduler wizard helps configure and preset recurring activities such as report generation data archival and task reminders SKF ptitude Analyst Powerful software for enterprise wide communications www skf com cm 7 Hardware requirements Minimum Requirements Recommended Requirements Operating system Windows 2000 with Service Pack 3 OR Windows XP Professional with Service Pack 2 Processor Note 1 Pentium IV 1 6 GHz Pentium IV 2 1 GHz Core 2 Duo or better RAM 1 0 GB 2 0 GB or more Disk space a for stand alone computer 1 2 GB 1 2 GB of more Note 2 CD DVD drive One 1 required One 1 required Video display 1024 x 768 1280 x 1024 or larger Oracle Microsoft SQL Version 9i 10g SQL Server 2005 Minimum Requirements Recommended Requirements Operating system Windows 2003 Server Windows 2000 Server
11. nt angle setting Date range setting User selectable color settings Waterfall spacing time date based or event Spectrum data post processing integration differentiation Baseline spectrum storage DATABASE Built on Oracle database management system e Microsoft SQL Server 2005 compatible e ODBC SQL and TCP IP protocol compliant database opens the database content e Fully networkable in a Local Area Network LAN Wide Area Network WAN and Thin client Terminal environments e Unlimited number of hierarchies collection points measurements e Database supports XML data importing and exporting Binary importing and exporting e Point configuration management to quickly and easily make system wide changes GENERAL e Multiple languages available e Windows based functionality True multi processing operating environment allowing simultaneous background and foreground processing Complete right click functionality drop down menus Drag and drop Cut Copy Paste Complete integration of third party applications e User preferences allow customization e Context sensitive help e Complete user manual on installation CD ROM e Product Support Plans PSP available MEASUREMENTS The following measurements can be entered manually or automatically e Acceleration e Amps Conditional points MARLIN e Displacement e English or metric units e Enveloped accelerati
12. on e Flow GPM LPM e High Frequency Detection HFD and Digital High Frequency Detection DHFD e Inspection points user definable e Multi channel e Operating hours Operating time elapsed and cumulative e Pressure PSI and bars e RPM e SEE Spectral Emitted Energy e SKF acceleration enveloping gE e Speed e Temperature C and F e Triax e User specific units e Velocity e Volts AC or DC e Derived Point user definable mathematical formula to calculate a derived value from data collected on multiple points REPORTS e Preserved reports enables you to maintain a history of reports e Shared reports allows you to share and preconfigure reports for selected users e Send reports to screen HTML file printer e HTML file can be posted to internet intranet e mailed e HTML files can be opened and modified further using Microsoft Office products i e Word Excel PowerPoint e Customizable report content e Data plots supplemental information and digital images can be included in reports e Report types Last measurement Exception Overdue non compliant Pending overdue non compliant Collection status Route history Route statistics Set statistics Upload statistics History Inspection Work notification Blank user defined Compliance e Report templates allow quick and easy report configuration for use and reuse SECURITY e Fu
13. rs www skf com cm 5 Automatically schedule reports to save time The Scheduler Wizard enables a user to automatically schedule a specific action such as generating a report upon completion of a data collection upload archiving measurement data at a specified time or other event based actions This capability helps to eliminate human error and allows the user to focus on other more pressing issues Using ptitude Analyst throughout your organization allows collaboration and communication without losing control of your data Fie Edt View Insert Transfer Customize Toos Window Hep bal e Aeee Ee BOR 8 ees s T POB S SSPE SHS Ole DAU DE InLine gE3 DE 90 deg Vel DE InLine Vel DE InLine gE3 DE 90deg Vel DE InLine Vel NDE Vert Vel DE Horiz oE3 For Help press F1 Work Notification Report Source Hierarchy 4 15 2007 2 41 19 PM Date Time 4 7 2007 7 56 40 PM 4 7 2007 7 56 40 PM 8 28 2006 4 01 41 PM 8 28 2006 4 01 34 PM 8 28 2006 4 01 26 PM 8 28 2006 4 01 16 PM 8 28 2006 4 01 06 PM 8 28 2006 4 00 57 PM 8 28 2006 4 00 43 PM 8 28 2006 0 7514969 0 7514969 0 07827998 6 449324 0 1367229 0 07812738 6 637013 6 59772 Last Measurement 0 7499373 0 7499373 Overall Danger Overall Alert Overall Alert uneo Predefined report templates make it easy to generate common reports such as last measurement exception overdue non compliant history route
14. s and machine information When you scroll across a data plot data values are displayed in the plot window Enhanced alarm view saves valuable time Alarm View window displays all points that require immediate attention to help you quickly identify and prioritize follow up activities The Alarm Details window offers a comprehensive list of the specific points in alarm and the level and type of alarm all in one convenient view Auto Linking makes it easy to view individual alarms because the data plots and alarm details change automatically as you select specific points saving time and simplifying the analysis process Versatile viewing options for multi parameter analysis For fast and easy comparison of two or more readings across multiple points ptitude Analyst allows you to select a measurement and drag and drop it into the plot providing convenience and saving time The SKF ptitude Analyst frequency analysis feature helps to identify specific bearing and gearbox frequency sets for rapid detection and correction of bearing and machine problems ptitude Analyst s on line data view automatically refreshes to display the latest information point status and alarm details Live views provide immediate update of displayed data while the Event Log documents specific occurrences over time The System Information view provides one stop navigation between different views such as Event Log On line Data vi
15. vel Advanced security system protects data Four standard security levels are provided within ptitude Analyst and an unlimited number of custom user security levels can be created Each level represents access rights that can be limited and controlled to prevent unauthorized use of the system and limit the possibility of inadvertent damage to your valuable program database POO AnH Properties Name Operator Senior Grade Default base level Operator X vf Microlog Transfer vf Modity Alarm Setup Modify Assignment for Shared Rep Modify Hierarchy Modify access right Allow For Help press F1 LINKED Personalized access rights allow the software administrator to protect against errors and enable traceability Customized reports SKF ptitude Analyst Powerful software for enterprise wide communications Extensive report customization features let the user control the specific kinds of machine information to be communicated throughout the organization You can customize the templates or design an entirely new report including data plots supplemental information and digital images Reports are generated in HTML format giving you the flexibility to view on screen print attach to an e mail or post the report to your company intranet automatically Other features allow you to maintain a history of reports pre configure report content and format to share with selected use